PRODUCT DIRECTORY 2014 TODAY’S IRRIGATION SYSTEMS are designed to last for decades. While sprinkler heads and other components may be upgraded over time, the pipe and wire used in a system must continue to perform reliably, year after year. For over 20 years, professionals have specified high-quality products from Regency Wire & Cable for all irrigation and landscape lighting applications. Regency’s line-up of solidly-constructed and carefully-tested wire and cable products includes solutions for irrigation zone wiring, central control cable, decoder cable and system grounding. All Regency products are manufactured in the United States at our vertically-integrated facility in Sikeston, Missouri. Beginning with top-grade raw copper, every step of manufacturing is handled in-house using state-of-the-art equipment and monitored by a dedicated team of talented technicians. An on-site laboratory tests samples from every production run, assuring that we meet or exceed all UL and NEC requirements as well as our own higher-level standards. In addition to providing outstanding products, Regency continually sets the industry benchmark for personalized service. At the factory and in the field, Regency’s veteran team of technical specialists, sales representatives and customer support personnel provides irrigation consultants, engineers, architects, distributors and contractors with knowledgeable, hands-on support. The Regency Advantage: Helping Our Customers Be Successful Availability: Unmatched in-stock inventory of all irrigation and low voltage lighting wire and cable for fast, same-day shipment. Total Solutions: From control wire to manufacturer-specific communication and decoder cables, Regency can supply all of the wire, cable and grounding solutions for systems of all sizes. Personalized Service: Friendly, knowledgeable service from a dedicated team of professionals who understand the industry and are committed to their customers’ success. Technical Know-How: Our veteran team understands project needs and can help you in specification and field troubleshooting. Customization: Our in-house capabilities allow us to custom-manufacture products to your specific requirements. RoHS Compliance Statement On January 27, 2003 the European Parliament and the Council of the European Union authorized Directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment. This new directive, also referred to as RoHS (“ro-has”) requires that manufacturers reduce usage of six hazardous substances to minimum acceptable levels by July of 2006. The six substances affected are: • Lead (Pb) • Mercury (Hg) • Cadmium (Cd) • Hexavalent chromium (Cr+6) • Polybrominated biphyenyl (PBB) • Polybrominated diphenyl ether (PBDE) RoHS Compliant Regency Wire & Cable is pleased to announce that its product line is rapidly becoming RoHS compliant. As you view the products in this wire directory look for the RoHS compliant logo to determine if the product you’re interested in meets the requirements of this directive. Underground Low Energy Circuit Cable PVC Insulation, 30 V Rating Part # Desc. Wt/1000’ 18UF(C)(P) 18 Solid 16UF(C)(P) 16 Solid Multi-Conductor Irrigation Control Cable PE Jacket with PVC Inner Insulation with Rip Cord, 600 V Rating ating Std. Pkg. Colors 13 4 x 500, 1 x 2500 1-12 Part # Desc. Wt./1000’ Std. Pkg. 17 4 x 500, 2 x 1000, 1 x 2500 1-12 18/02(P) 18 Solid / 2 Cond. 20 2 x 250, 2 x 500, 1 x 1000, 1 x 2500 18/03(P) 18 Solid / 3 Cond. 27 2 x 250, 2 x 500, 1 x 1000, 1 x 2500 18/04(P) 18 Solid / 4 Cond. 34 2 x 250, 2 x 500, 1 x 1000, 1 x 2500 18/05(P) 18 Solid / 5 Cond. 43 2 x 250, 2 x 500, 1 x 1000, 1 x 2500 18/06(P) 18 Solid / 6 Cond. 49 2 x 250, 2 x 500, 1 x 1000, 1 x 2500 18/07(P) 18 Solid / 7 Cond. 57 2 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/08(P) 18 Solid / 8 Cond. 64 2 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/09(P) 18 Solid / 9 Cond. 71 2 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/10(P) 18 Solid / 10 Cond. 79 2 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/12(P) 18 Solid / 12 Cond. 93 2 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/13(P) 18 Solid / 13 Cond. 100 1 x 250, 1 x 500, 1 x 1000, 1 x 2500 18/16(P) 18 Solid / 16 Cond. 123 1 x 250, 1 x 500, 1 x 1000 18/19(P) 18 Solid / 19 Cond. 144 1 x 250, 1 x 500, 1 x 1000 18/25(P) 18 Solid / 25 Cond. 185 1 x 250, 1 x 500, 1 x 1000 Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ UF Irrigation Cable PVC Insulation, 600 V Rating, ating ating, Underground FFeeder Cable Part # Desc. Wt./1000’ Std. Pkg. Colors 14UF(C)(P) 14 Solid 28 2 x 500, 1 x 2500 1-12 12UF(C)(P) 12 Solid 37 2 x 500, 1 x 2500 1-12 10UF(C)(P) 10 Solid 51 2 x 500,1 x 1000, 1 x 2500 1-9, 11 08UF(C)(P) 8 Solid 76 1 x 500, 1 x 1000, 1 x 2500 1-8 06UF(C)(P) 6 Str 120 1 x 500, 1 x 1000, 1 x 2500 1-5 04UF(C)(P) 4 Str 175 1 x 500, 1x 1000, 1 x 2500 1, 2, 3, 5 02UF(C)(P) 2 Str 280 1 x 500, 1 x 1000, 1 x 2500 1, 2, 3, 5 Put-Up Code(P): 1-500’, 2-1000’ Put-Up Code(P): 0-250’, 1-500’, 2-1000’, 5-2500’ PE Sprinkler Systems Cable P ly Po l ye ye thyl y ene Insulation, yl 600 V Rating, g, Direct Burial g Part # Desc. Wt./1000’ Std. Pkg. Colors 14PE(C)(P) 14 Solid 20 2 x 500, 1 x 2500 1-12 12PE(C)(P) 12 Solid 27 2 x 500, 1 x 2500 1-9, 11 10PE(C)(P) 10 Solid 40 2 x 500, 1 x 2500 1-2, 5, 6 Put-Up Code(P): 1-500’ , 2-1000’, 5-2500’ Flat Jacketed—Type UF-B w/Ground-Direct Burial PVC Insulation with THHN/THWN Inners, 600 V Rating Low Voltage Lighting Cable PVC Insulation, Flexible, Stranded Low Energy Lighting Cable, 30 V Rating Part # Desc. Wt./1000’ Wt./1000’ Std. Pkg. 18LC1(P) 18 Str / 2 Cond. 27 4 x 250, 2 x 500 142CWGJK(P)/143CWGJK(P) 14 Solid 2/3 with ground 53/93 1 x 500, 1 x 1000 16LC1(P) 16 Str / 2 Cond. 33 2 x 250, 2 x 500, 1 x 1000 122CWGJK(P)/123CWGJK(P) 12 Solid 2/3 with ground Part # Desc. Std. Pkg. 75/134 1 x 500, 1 x 1000 14LC1(P) 14 Str / 2 Cond. 47 2 x 250, 2 x 500, 1 x 1000 102CWGJK(P)/102CWGJK(P) 10 Solid 2/3 with ground 140/194 1 x 500, 1 x 1000 12LC1(P) 12 Str / 2 Cond. 69 2 x 250, 1 x 500, 1 x 1000 082CWGJK(P)/083CWGJK(P) 8 Str 2/3 with ground 213/330 1 x 500, 1 x 1000 10LC1(P) 10 Str / 2 Cond. 95 1 x 250, 1 x 500 062CWGJK(P)/063CWGJK(P) 6 Str 2/3 with ground 305/449 1 x 500, 1 x 1000 08LC1(P) 8 Str / 2 Cond. 155 1 x 250, 1 x 500 Put-Up Code(P): 0-250’, 1-250’, 1-500’, 2-1000’, 5-2500’ Put-Up Code(P): 0-250’, 1-500’, 2-1000’ Tray Cable, Type TC-Direct Burial Bare Copper Wire Soft Drawn Bare Copper, Suitable for Grounding Purposes Awg Size Stranding Wt./1000’ Std. Pkg. PVC Insulation with THHN/THWN Inners, 600 V Rating 14 Solid 12.4 2 x 2000’, 4 x 500’, 2 x 1000’ Part # 12 Solid 19.8 2 x 1250’, 4 x 500’, 2 x 1000’ 10 Solid 31.5 2 x 800’, 4 x 500’, 1 x 1000’ 8 Solid 50 6 Solid 4 2 Desc. Wt./1000’ Std. Pkg. 123CTC(P) 12 Str / 3 Cond. 141 1 x 500, 1 x 1000 103CTC(P) 10 Str / 3 Cond. 209 1 x 500, 1 x 1000 4 x 500’, 1 x 1000’ 083CTC(P) 8 Str / 3 Cond. w/grd. 323 1 x 500, 1 x 1000 79.5 4 x 315’, 1 x 500’, 1 x 1000’ 063CTC(P) 6 Str / 3 Cond. w/grd. 536 1 x 500, 1 x 1000 Solid 126.3 4 x 200’, 1 x 500’, 1 x 1000’ 043CTC(P) 4 Str / 3 Cond. w/grd. 701 1 x 500, 1 x 1000 Solid 200.9 2 x 125’, 1 x 500’, 1 x 1000’ 023CTC(P) 2 Str / 3 Cond. w/grd. 1020 1 x 500, 1 x 1000 8 7 Str 51 4 x 500’, 1 x 1000’ 6 7 Str 81 4 x 315’, 1 x 500’, 1 x 1000’ 4 7 Str 128.9 4 x 200’, 1 x 500’, 1 x 1000’ 2 7 Str 204.9 2 x 125’, 1 x 500’, 1 x 1000’ Put-Up Code(P): 1-500’, 2-1000’ Hunter® Twisted Decoder Cable Jacketed ® Hunter Twisted Decoder Cable Soft Drawn Bare Copper, PE, 600 V Rating Soft Drawn Bare Copper, PE, 600 V Rating Awg Size Stranding Wt./1000’ Std. Pkg. Awg Size Stranding Wt./1000’ Std. Pkg. 14 Solid 55.6 1 x 500, 1 x 1000, 1 x 2500 14 Solid 43.4 1 x 500, 1 x 1000, 1 x 2500 12 Solid 75 1 x 500, 1 x 1000, 1 x 2500 12 Solid 61.6 1 x 500, 1 x 1000, 1 x 2500 Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ Parallel Communication Cable Toro® Decoder Cable Awg Size Soft Drawn Bare Copper, PVC, 600 V Rating Stranding Soft Drawn Bare Copper, PE, 600 V Rating Wt./1000’ Std. Pkg. Awg Size Stranding Wt./1000’ Std. Pkg. 14 Solid 76 1 x 500, 1 x 1000, 1 x 2500 14 Solid 80 1 x 500, 1 x 1000, 1 x 2500 12 Solid 103 1 x 500, 1 x 1000, 1 x 2500 Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ Communication Cables Soft Drawn Bare Copper Part No. Awg Size No. of Pairs Wt./1000’ Std. Pkg. PE-39 19 6 167 1 x 500, 1 x 1000 PE-89 22 6 78 1 x 500, 1 x 1000 PE-54 19 3 84 1 x 500, 1 x 1000 DBS203P 20 3 59.7 1 x 500, 1 x 1000 1804S 18 2 65 1 x 500, 1 x 1000 Toro® Communication Cable Soft Drawn Bare Copper, PVC, 600 V Rating Awg Size Stranding Wt./1000’ Std. Pkg. 16 7 Strand 54 1 x 500, 1 x 1000, 1 x 2500 Put-Up Code(P): 1-500’, 2-1000’, 5-2500’ Put-Up Code(P): 1-500’, 2-1000’ 830 South West Street • Sikeston, Missouri 63801 • 800.876.3020 • 573.472.2990 • Fax800.333.5676 www.regencywire.com Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3, B-8 and B-787. Gauge sizes 14 thru 8 are solid conductors. Sizes 6 thru 4/0 are stranded conductors. The insulation is a high quality polyvinylchloride (PVC) for systems applications of up to 600 volts and conductor temperatures up to 60° C. Application: Suitable for use as direct burial power and control wire for irrigation systems. Conductor: Soft drawn bare copper (ASTM Specs. B-3, B-8 and B-787), Solid (14 awg thru 8 awg), Stranded (6 awg thru 4/0 awg). Insulation: Polyvinylchloride (PVC) Temperature: 60° C Voltage: 600 volts Conductor Size 14 awg thru 10 awg 8 awg thru 2 awg Insulation Thickness .060 .080 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. Regency’s Type UF cables are intended for use in accordance with Article 339 and other applicable parts of the National Electrical Code in wiring systems operating at a potential of 600 V or less. RoHS Compliant Please visit www.regencywire.com for complete specifications. PE Sprinkler Systems Wire Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 thru 10 are solid conductors. The insulation is a linear low density, high molecular weight polyethylene for systems applications of up to 600 volts. Application: Suitable for use as direct burial power and control wire for irrigation systems. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 600 volts Conductor Size 14 awg thru 10 awg Insulation Thickness .045 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Electrical — AC test voltage, 60 seconds at 7500 volts. Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. Regency’s single conductor PE Sprinkler Systems Wire is manufactured for the purpose of direct burial power wire applications in accordance with the National Electric Code. RoHS Compliant CONTROL WIRE UF-TWU Irrigation Wire Multi Conductor Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The 18 awg conductors are solid copper. The insulation is a color coded high quality polyvinylchloride (PVC) for systems applications of up to 600 volts and conductor temperatures up to 60° C. The outer jacket is linear low density, high molecular weight, sunlight resistant, polyethylene (PE) with a nylon cord. Application: Suitable for use as direct burial control cable for wiring central control systems to field controls. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (18 awg). Insulation: Color coded polyvinylchloride (PVC) Outer Jacket: Black polyethylene (PE) Temperature: 60° C Voltage: 600 volts Conductor Size and No. 18-2 18-3 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-12 18-13 18-16 18-19 18-25 Conductor Insulation .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 Outer Jacket .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 RoHS Compliant Regency Wire & Cable Underground Low Energy Circuit Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 18 and 16 are solid conductors. The insulation is a high quality polyvinylchloride (PVC) for systems applications of up to 30 volts and conductor temperatures up to 60° C. Application: Suitable for use as direct burial power and control wire for irrigation systems. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (18 awg and 16 awg). Insulation: Polyvinylchloride (PVC) Temperature: 60° C Voltage: 30 volts Conductor Size 18 awg thru 16 awg Insulation Thickness .045 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Electrical — AC test voltage, 60 seconds at 5000 volts. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. Regency’s single conductor Low Energy Circuit Cable is manufactured for the purpose of direct burial power wire applications in accordance with the National Electric Code. RoHS Compliant Conductor construction is soft drawn bare copper meeting ASTM Specifications B-3 & B-787. THWN is available as stranded in sizes 14 thru 4/0 and solid in sizes 14 thru 10. The insulation is a high quality polyvinylchloride (PVC) with a nylon jacket for systems applications of up to 600 volts and conductor temperatures up to 75° C. Application: Suitable for use as power wire for irrigation systems, when buried in conduit. Conductor: Soft drawn bare copper meeting applicable ASTM Specifications, Stranded (14 awg thru 4/0 awg), Solid (14 awg thru 10 awg). Insulation: Polyvinylchloride (PVC) Jacket: Nylon Temperature: 90° C Voltage: 600 volts Conductor Size 14 awg thru 12 awg 10 awg 8 awg thru 6 awg 4 awg thru 2 awg 1 awg thru 4/0 awg Insulation Thickness 15 20 30 40 50 Jacket Thickness 4 4 5 6 7 RoHS Compliant 800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com Flat Jacketed–Type UF-B Regency’s Type UF cables are intended for use in accordance with Article 339 and other applicable parts of the National Electrical Code in wiring systems operating at a potential of 600 V or less. Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-787. Gauge sizes 14 and 10 are solid copper conductors. Sizes 8 thru 6 are stranded conductors. All ground wires are solid. The insulation is a color coded THHN / THWN type for wet, dry or corrosive applications of up to 600 volts and conductor temperatures up to 75° C. The outer jacket is a sunlight resistant, high quality polyvinylchloride (PVC). Application: Suitable for use as direct burial or indoor branch circuit wiring. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg thru 10 awg), Stranded (8 awg and 6 awg), Solid ground. Insulation: Polyvinylchloride (PVC) with a nylon sheath Outer Jacket: Polyvinylchloride (PVC) Temperature: 75° C Voltage: 600 volts Conductors 2 w/grd 3 w/grd 2 w/grd 3 w/grd 2 w/grd 3 w/grd 2 w/grd 3 w/grd 2 w/grd 3 w/grd Gauge Size 14 14 12 12 10 10 8 8 6 6 Conductor Stranding Solid Solid Solid Solid Solid Solid Stranded Stranded Stranded Stranded Ground Size 14 14 12 12 10 10 10 10 10 10 CONTROL WIRE / POWER WIRE THHN/THWN-2 Tray Cable Type TC Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-787. Gauge sizes 12 thru 2 are stranded copper conductors. The insulation is a color coded polyvinylchloride (PVC) rated for continuous use at 90° C dry or wet and up to 600 volts. Each insulated conductor is sheathed with a nylon jacket that meets the requirements for THHN or THWN wire. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial. The Tray Cable will have a polyvinylchloride (PVC) outer jacket. Application: Suitable for use as power and control tray cable in direct burial applications. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-787), Stranded (12 awg thru 2 awg). Insulation: Polyvinylchloride (PVC) with a nylon jacket Outer Jacket: Polyvinylchloride (PVC) Temperature: 90° C dry or wet Voltage: 600 volts Gauge Number of Conductor Conductor Jacket Color Size Conductors Stranding Colors 12 3 19 Black, Red, Blue Black 10 3 19 Black, Red, Blue Black 8 3 w/bare grd. 19 1-2-3 Black 6 3 w/bare grd. 19 1-2-3 Black 4 3 w/bare grd. 19 1-2-3 Black 2 3 w/bare grd. 19 1-2-3 Black Call Regency Wire and Cable for availability of other sizes and number of conductor tray cables. RoHS Compliant Regency Wire & Cable Toro® Communication Cable — Shielded/Armored Conductor construction is tin coated, soft drawn bare copper meeting the requirements of ASTM Specification B-33. The two conductors shall be insulated with a high quality polyvinylchloride (PVC) covered with a clear nylon sheath for systems applications up to 600 volts. One conductor will be insulated yellow and the other conductor insulated gray. Shielded: A 2 mil aluminum backed polyester shielding with a 16 awg solid tinned copper drain wire in contact with the aluminum side is applied. The shield has a 25% minimum overlap. Armored: The conductors and shielding are armored by helically wrapping the core with a .005” x .500” type 304 stainless steel tape. The armor has a minimum 25% overlap. A polyethylene (PE) jacket covers the assembly. Application: Suitable for use as Toro’s® communication cable for control of Toro® golf course sprinkler systems. Conductor: Tin coated, soft drawn bare copper (ASTM Spec. B-33). Two (2) conductors. Stranded (16 awg). Insulation: Polyvinylchloride (PVC) with a nylon sheath Outer Jacket: Polyethylene (PE) Temperature: 90° C Voltage: 600 volts Gauge Size 16 Strand 7 Insulation Thickness .015 Regency’s Toro® Communication Cable is manufactured for direct burial application of Toro’s® golf course sprinkler systems. Outer Jacket Thickness .045 RoHS Compliant Conductor construction is tin coated, soft drawn bare copper meeting the requirements of ASTM Specification B-33. The two conductors shall be insulated with a high quality polyvinylchloride (PVC) for systems applications up to 600 volts. One conductor will be insulated black and the other conductor insulated red. Both conductors shall be of the same size as specified and/or shown on the drawings and as required for the proper operation of the Satellite and Decoder units connected to it. The two conductors shall be laid parallel and pressure extruded with a solid color, linear high density, sunlight resistant polyethylene (PE) outer jacket. The jacket comes in a variety of colors to accommodate easy identification. Comes with pull cord for easy stripping. Application: Suitable for use as Rain Bird’s® communication wire for control of Maxi control systems. Conductor: Tin coated, soft drawn bare copper (ASTM Spec. B-33), Two (2) conductors, Solid (14 awg and 12 awg). Insulation: Polyvinylchloride (PVC) Outer Jacket: Polyethylene (PE) Temperature: 60° C Voltage: 600 volts Gauge Size 14 12 Conductor Insulation .060 .060 Outer Jacket .045 .045 Regency’s Decoder Cable is manufactured for the purpose of direct burial applications in accordance with the National Electric Code. RoHS Compliant Please visit www.regencywire.com for complete specifications. 1804S Irrigation Control Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-8. The insulation is color coded polyvinylchloride (PVC). Each insulated conductor is sheathed with a clear nylon jacket and is twisted and color coded to facilitate pair identification. The cable is then wrapped with an aluminum polyester tape. Application: Suitable for control circuits for operation and interconnection of protective and signaling devices. U.L. listed and labeled for installation in duct, conduit and wireways. May be used in wet or dry locations, sunlight resistant, and suitable for direct burial. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Four (4) conductors, Stranded. Insulation: Polyethylene (PE) Conductor Size 18 awg Number of Conductors 4 Temperature: 90° C dry, 75° C wet Voltage: 600 volts Resistance: 6.92 OHMS per M at 68° F Capacitance: 44.8 Pico Farads Nominal Lbs./M': 65 Color Coding: Per ICEA method 1; Pairs – black and white. One conductor in each pair is printed alphanumerically for easy identification. Conductor Stranding 7 Drain Wire: 20 awg tinned copper laid between aluminum shield and PVC insulation Insulation: Polyvinylchloride (PVC) with a nylon sheath. Nominal insulation thickness .015". Nylon thickness .004" Outer Jacket: Polyvinylchloride (PVC) Nom. jacket thickness .045" Nominal O.D.: .335" Shield: Aluminum/Polyester Regency’s Irrigation Control Cable is manufactured for the purpose of power and control cable applications in accordance with the National Electric Code. POWER WIRE / COMMUNICATION CABLE Parallel Communication Cable DBS203P Communication Cable Conductor construction is soft drawn tinned bare copper meeting the requirements of ASTM Specification B-33. The conductors are 20 awg stranded with a polypropylene insulation. Each of the insulated pairs are twisted and color coded to facilitate pair identification with an aluminum polyester tape shielding and a drain wire. The overall jacket is constructed with polyethylene insulation. The cable assembly is then longitudinally wrapped with an electrically continuous thick polymer-coated smooth aluminum tape overlapped to give 100% coverage. Application: Suitable for use in requirements in communication for weather station or pump station control equipment. U.L. listed and labeled for direct burial. Conductor: Soft drawn tinned bare copper (ASTM Spec. B-3). Conductor Size 20 awg Number of Pairs 3 Voltage: 350 volts Nominal O.D.: .334" Cable Wt.: 59.77 lb. / 1000' Color Coding: Pair 1 - Black, Red; Pair 2 - Black, White; Pair 3 - Black, Green Print Legend: Regency Wire 3 Pair 20 awg Shielded DBS203P U.L. Conductor Stranding 10 x 30 Insulation: Polypropylene, nominal insulation thickness .0150" Shielding: .00235" aluminum polyester tape, helically wrapped, over each pair giving 100% shielding Drain Wires: 20 awg tinned copper drain wire, for each pair laid under the shield in contact with aluminum side for each pair Jacket: .040" black sunlight resistant polyethylene Resistance: 10.9 OHMS Per M at 68° F Capacitance: 25.7 Pico Farads Nominal Regency’s DBS203P Communication Cable is a three (3) pair cable manufactured for the purpose of direct burial systems communication for weather and pump station applications in accordance with the National Electric Code. Regency Wire & Cable PE-89 Communication Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The conductors are 22 awg solid copper. The conductors are insulated with polyethylene (PE) in distinctive colors to facilitate pair identification and are twisted into pairs with varying lays to minimize crosstalk. The interstices between the pairs are filled with an 80° C filling compound and covered with a low density, high molecular weight black polyethylene (PE). The assembly is then wrapped with two metal shield tapes: A corrugated .008" thick polymer coated aluminum tape and a corrugated .006" polymer coated steel tape. Application: Suitable for use as direct burial communication applications where protection against water and moisture entry is a critical requirement. PE-89 is recommended where rodent attack is possible. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (22 awg). Insulation: Polyethylene (PE) Outer Jacket: Polyethylene (PE) Temperature: 60° C Resistance: 17.235 OHMS Per M Feet at 68° F Number of Pairs 6 Outside Diameter .40 in. Regency’s PE-89 Communication Cable is a six (6) pair cable manufactured for the purpose of direct burial systems communication applications in accordance with the National Electric Code. Cable Weight 78 / M' Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The conductors are 19 awg solid copper. The conductors are insulated with polyethylene (PE) in distinctive colors to facilitate pair identification and are twisted into pairs with varying lays to minimize crosstalk. The interstices between the pairs are filled with Waterbloc compound and covered with a non-hygroscopic core wrap. The inner and outer surfaces of the core wrap are coated with Waterbloc compound. The assembly is then longitudinally wrapped with a corrugated .008" (0.2 mm) thick copolymer-coated aluminum tape. This tape reduces the possibility of shield corrosion and lightning damage. The outer surface of the shield is flooded with Enviroblock compound. The outer jacket is polyethylene (PE). Application: Suitable for use as direct burial communication applications where protection against water and moisture entry is a critical requirement. PE-39 is recommended where rodent attack is possible. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (19 awg). Insulation: Polyethylene (PE) Outer Jacket: Polyethylene (PE) Temperature: 60° C Voltage: 8.523 OHMS Per M Feet at 68° F Number of Pairs 6 Outside Diameter .061 Cable Weight 137 / M' Regency’s PE-39 jacketed cable is manufactured for the purpose of direct burial power wire applications in accordance with the National Electric Code. 800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com PE Pet Containment Wire — 30 mil Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 thru 10 are solid conductors. The insulation is a linear low density, high molecular weight polyethylene for systems applications of up to 600 volts. Application: Suitable for use as tracer wire or pet containment wire. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 30 volts Conductor Size 14 awg thru 10 awg Insulation Thickness .030 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Electrical — AC test voltage, 60 seconds at 7500 volts. Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. RoHS Compliant COMMUNICATION CABLE / PET CONTAINMENT WIRE PE-39 Communication Cable Low Voltage Lighting Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-174. Sizes 18-2, 12-2, 10-2 and 8-2 have flexible stranding conductors. The insulation is a high quality polyvinylchloride (PVC) for conductor temperatures up to 60° C. Application: Suitable for use in direct burial landscaping and lighting applications. Sunlight resistant. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-174), Flexible Stranded (18 awg thru 8 awg). Insulation: Polyvinylchloride (PVC) Temperature: 60° C Voltage: 30 volts Insulation Conductor Size Stranding Thickness 18 16 .045 16 26 .045 14 41 .045 12 65 .045 10 105 .045 8 165 .060 • Call regarding colors other than black. RoHS Compliant Regency’s Low Voltage Lighting Cable is manufactured for the purpose of direct burial landscape and lighting applications. Regency Wire & Cable Hunter® Decoder Cable Non-Jacketed Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 thru 10 are solid conductors. The insulation is a low density, high molecular weight polyethylene. The conductors are twisted for systems applications of up to 600 volts. UV inhibitors added for color stability. Conductor colors are blue and red and shall be twisted with a 4" lay. Application: Suitable for use as power and control wire of irrigation systems. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg and 12 awg). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 600 volts Conductor Size 14 awg and 12 awg Insulation Thickness .060 RoHS Compliant Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 and 12 are solid conductors. The conductors are twisted for systems applications of up to 600 volts. Conductor colors are blue and red and shall be twisted with a 4” lay. The jacket comes in a variety of colors to accommodate easy identification. Comes with pull cord for easy stripping. Application: Suitable for use as power and control wire of irrigation systems. Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (14 awg and 12 awg). Insulation: Polyethylene (PE) Outer Jacket: High Density Polyethylene (HDPE) Temperature: 75° C Voltage: 600 volts Conductor Size 14 awg and 12 awg Insulation Thickness .045 Jacket Thickness .035 Regency’s Decoder Cable is manufactured for the purpose of direct burial applications in accordance with the National Electric Code. RoHS Compliant Please visit www.regencywire.com for complete specifications. Toro® GDC Decoder Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Toro® GDC Decoder Cable features solid copper conductors. The conductors are twisted with a 4” lay and rated for systems applications of up to 600 volts. Individual conductor colors are black and white. Comes with pull cord for easy stripping. Application: Suitable for use in direct burial applications for communication with and control of Toro® decoder systems. Conductor: Solid soft drawn bare copper (ASTM Spec. B-3 or B-8). Insulation: Polyethylene (PE) Outer Jacket: High Density Polyethylene (HDPE) Temperature: 60° C Voltage: 600 volts Conductor Size 14 awg Insulation Thickness .045 Regency’s Decoder Cable is manufactured for the purpose of direct burial applications in accordance with the National Electric Code. Jacket Thickness .035 RoHS Compliant LIGHTING CABLE / DECODER CABLE Hunter® Decoder Cable Jacketed Decoder / Solenoid Cable Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3. The insulation is a linear low density, high molecular weight polyethylene (PE) for conductor temperatures up to 75° C. A raised polarity ridge is present on one leg. Application: Suitable for use with decoder systems in direct burial applications. Conductor: Solid, soft drawn bare copper (ASTM Specs. B-3). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 600 volts Conductor Size 14 Insulation Thickness .045 RoHS Compliant Regency Wire & Cable PE Tracer Wire — 45 mil Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 thru 10 are solid conductors. The insulation is a linear low density, high molecular weight polyethylene for systems applications of up to 600 volts. Application: Suitable for use as tracer wire. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 600 volts Conductor Size 14 awg thru 10 awg Insulation Thickness .045 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Electrical — AC test voltage, 60 seconds at 7500 volts. Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. RoHS Compliant Regency’s single conductor Tracer Wire is manufactured for the purpose of direct burial power wire applications in accordance with the National Electric Code. DECODER CABLE / TRACER WIRE / THERMOSTAT WIRE PE Tracer Wire — 30 mil Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. Gauge sizes 14 thru 10 are solid conductors. The insulation is a linear low density, high molecular weight polyethylene for systems applications of up to 600 volts. Application: Suitable for use as tracer wire.. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg). Insulation: Polyethylene (PE) Temperature: 75° C Voltage: 30 volts Conductor Size 14 awg thru 10 awg Insulation Thickness .030 Material must be able to pass the following tests without showing signs of degradation: Cold Bend — The insulation shall not show any cracks when sample is bent around a 3X mandrel after being subjected to –25° C for four (4) hours. Electrical — AC test voltage, 60 seconds at 7500 volts. Mechanical Water Absorption — Insulation shall not absorb more than 25 mg mass of water per square inch. Sunlight Resistance Test — Samples conditioned for 300 hours of carbon-arc or xenon-arc exposure. RoHS Compliant 800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com Thermostat Wire Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specification B-3. The 20 awg conductors are solid copper. The insulation is a color coded high quality polyvinylchloride (PVC) for conductor temperatures up to 75° C. The outer jacket is brown polyvinylchloride (PVC). Conductor: Soft drawn bare copper (ASTM Spec. B-3), Solid (20 awg). Insulation: Color coded polyvinylchloride (PVC) Outer Jacket: Brown polyvinylchloride (PVC) Temperature: 75° C Voltage: 30 volts Regency’s Thermostat Wire is manufactured for the purpose of thermostat applications in accordance with the National Electric Code. Conductor Size and Number 20-2 20-3 20-4 20-5 20-6 20-7 20-8 20-9 20-10 20-12 Conductor Insulation .008 .008 .008 .008 .008 .008 .008 .008 .008 .008 Outer Jacket .013 .013 .013 .013 .013 .013 .013 .013 .013 .013 Cadweld Cadwelds Regency Part # Size Flint Type Control Unit Type GR1161G 6 and 8 awg CGR1161G CGR1161G-PLUS GR1161L 4 awg CGR1161L CGR1161L-PLUS GR1161V 2 awg CGR1161V CGR1161V-PLUS GT1161G 6 and 8 awg CGT1161G CGT1161G-PLUS GT1161L 4 awg CGT1161L CGT1161L-PLUS GT1161V 2 awg CGT1161V CGT1161V-PLUS NT1161G 6 and 8 awg CNT1161G CNT1161G-PLUS NT1161L 4 awg CNT1161L CNT1161L-PLUS NT1161V 2 awg CNT1161V CNT1161V-PLUS NX1161G 6 and 8 awg CNX1161G CNX1161G-PLUS NX1161L 4 awg CNX1161L CNX1161L-PLUS 1 Way 2 Way 3 Way 4 Way * If ordering flint type Cadweld order CT320 igniter. * If ordering control unit type Cadweld order ERIPLUSCU igniter. Regency Wire & Cable Cadweld Igniters Flint Gun Regency Part # CT320 Control Unit Regency Part # ERIPLUSCU CADWELD / GROUNDING Ground Rods Ground Rods 5/8" Diameter x 8' 5/8" Diameter x 10' UL ® Ground Rods are suitable for use as grounding electrodes in accordance with ANSI/NFPA 70, National Electrical Code (NEC), and are also suitable for use in installation of lightning protection equipment. Please visit www.regencywire.com for complete specifications. Ground Enhancing Material (GEM) Estimated bags of GEM for backfilling around ground rods to a density of 1442 kg/m3 (90 lb/cu ft). Diameter of Hole Depth of Hole (feet) 1.8 m (6') 2.1 m (7') 2.4 m (8') 2.7 m (9') 5.2 m (17') 5.8 m (19') 6.1 m (20') 7.5 cm (3") 2 2 2 2 4 4 4 10.0 cm (4") 2 3 3 3 6 7 7 12.5 cm (5") 3 4 4 5 9 10 10 15.0 cm (6") 5 5 6 7 13 14 15 17.5 cm (7") 6 7 8 9 17 19 20 20.0 cm (8") 8 9 11 12 22 25 26 22.5 cm (9") 10 12 13 15 28 31 32 25.0 cm (10") 12 14 16 18 34 38 40 Regency Part # GEM Bare Copper Wire Conductor construction is soft drawn bare copper meeting the requirements of ASTM Specifications B-3 and B-8. Gauge sizes 14 thru 10 are solid copper.r.r Sizes 8 thru 2 are available in either solid or 7 stranded. Gauge size 1/0 thru 4/0 is available in either 7 or 19 stranded. Application: Suitable for use in grounding purposes. Conductor: Soft drawn bare copper (ASTM Specs. B-3 and B-8), Solid (14 awg thru 10 awg), Solid or 7 stranded (8 awg thru 2 awg), 7 or 19 stranded (1/0 awg thru 4/0 awg). Size 14 12 10 8 6 4 2 Stranding Solid Solid Solid Solid / 7 STR Solid / 7 STR Solid / 7 STR Solid / 7 STR Regency’s Bare Copper Wire is manufactured for grounding purposes in accordance with the National Electric Code. Gross Weight Per MFT 12 20 32 51 81 129 205 Regency Wire & Cable Ground Plate w/Insulated Ground Wire Grroouunnddiinngg wi G wirree co connssttrruuccttiioonn is .015 Polyethylene insulated soft drawn copper meeting the requirements of ASTM Specification B-3. The plate is cut to size from sheets of copper allow 110. The ground wire is connected to the plate with a weld joint. Application: Suitable for use in grounding applications as an alternative to ground rods. Construction Plate: Copper alloy 110 Conductor: Soft drawn insulated 6 awg solid copper (ASTM Spec. B-3) Insulation: .015 Polyethylene (PE) Plate Dimensions 12" x 36" x .064 4" x 96" x .064 4" x 36" x .064 Ground Wire Length 10' 25' 25' Ground Wire Size 6 awgg 6 awgg 6 awgg Regency’s Grounding Plates are manufactured for the purpose of grounding applications as an alternative to ground rods. Underground Low Energy Circuit Cable Part # Desc. Wt/1000’ Std. Pkg. Multi-Conductor Irrigation Control Cable Colors Part # Desc. Wt./1000’ Std. Pkg. UF Irrigation Cable Part # Desc. Wt./1000’ Std. Pkg. Colors PE Sprinkler Systems Cable Part # Flat Jacketed—Type UF-B w/Ground-Direct Burial Desc. Wt./1000’ Wt./1000’ Std. Pkg. Colors Low Voltage Lighting Cable Part # Part # Desc. Desc. Wt./1000’ Std. Pkg. Std. Pkg. 800.876.3020 • 573.472.2990 • Fax 800.333.5676 • www.regencywire.com 830 South West Street, Sikeston, Missouri 63801 800.876.3020 • 573.472.2990 • Fax 800.333.5676 www.regencywire.com