TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the market leader in quality, durability, and product development. The latest development in the TeSys™ family of IEC contactors and overload relays is component high-fault short-circuit current ratings (SCCRs). TeSys K and D Contactors SCCRs identify the level of fault current that a component or assembly can safely withstand. Without knowing the available fault current and SCCR, it is impossible to determine if components or equipment can be safely installed. The new high-fault component SCCRs are available for all TeSys K and D contactors and overload relays, including the TeSys D solid-state overload relays. Component ratings provide the flexibility to choose the desired level of protection, up to the rated maximum, and use it without the need for specific tested combinations and confusing tested combination spreadsheets. Component ratings are available when using either fuse or circuit breaker protection. TeSys High-Fault Component Short-Circuit Current Ratings: TeSys K and D Overload Relays 65 kA on any system up to 480 Vac and 32 amps protected by a circuit breaker 100 kA on any system up to 480 Vac and greater than 32 amps protected by a circuit breaker 100 kA on any system up to 600 Vac protected by Class CC or J fuses And the best part about component ratings? You know you have the right SCCR when you see it on the label! Make the most of your energy SM TeSys D Overload Relays Class 10 Class 10 with Class 20 with without Single-Phase Single-Phase Single-Phase Sensitivity Sensitivity Sensitivity Maximum Component SCCR (kA)[1] Class 20 without Circuit Breakers Fuses Single-Phase @ 480 V[2] @ 600 V[3] Sensitivity Max. SCCR (kA) Max. SCCR (kA) 0.10 – 0.16 LRD01 LR3D01 — — 65 100 0.16 – 0.25 LRD02 LR3D02 — — 65 100 0.25 – 0.40 LRD03 LR3D03 — — 65 100 0.40 – 0.63 LRD04 LR3D04 — — 65 100 0.63 – 1 LRD05 LR3D05 — — 65 100 Current Setting Range (A) 1 – 1.6 For Direct Mounting to LC1… LRD06 LR3D06 — — 65 100 1.6 – 2.5 D09 – D32 LRD07 LR3D07 — — 65 100 2.5 – 4 LRD08 LR3D08 LRD1508 LR3D1508A 65 100 4–6 LRD10 LR3D10 LRD1510 LR3D1510A 65 100 5.5 – 8 LRD12 LR3D12 LRD1512 LR3D1512A 65 100 7 – 10 LRD14 LR3D14 LRD1514 LR3D1514A 65 100 9 – 13 D12 – D32 LRD16 LR3D16 LRD1516 LR3D1516A 65 100 12 – 18 D18 – D32 LRD21 LR3D21 LRD1521 LR3D1521A 65 100 16 – 24 LRD22 LR3D22 — — 65 100 17 – 25 — — LRD1522 LR3D1522A 65 100 LRD32 LR3D32 — — 65 100 — — LRD1530 LR3D1530A 65 100 — — LRD1532 LR3D1532A 65 100 LRD35 LR3D35 — — 65 100 9 – 13 LRD313 LR3D313 LRD313L — 100 100 12 – 18 LRD318 LR3D318 LRD318L — 100 100 16 – 25 LRD325 LR3D325 LRD325L — 100 100 LRD332 LR3D332 LRD332L — 100 100 LRD340 LR3D340 LRD340L — 100 100 37 – 50 LRD350 LR3D350 LRD350L — 100 100 48 – 65 D50A – D65A[4] LRD365 LR3D365 LRD365L — 100 100 LRD3322 LR3D3322 LR2D3522 LR3D3522 100 100 LRD3353 LR3D3353 LR2D3553 LR3D3553 100 100 LRD3355 LR3D3355 LR2D3555 LR3D3555 100 100 LRD3357 LR3D3357 LR2D3557 LR3D3557 100 100 LRD3359 LR3D3359 LR2D3559 LR3D3559 100 100 LRD3361 LR3D3361 LR2D3561 LR3D3561 100 100 LRD3363 LR3D3363 LR2D3563 LR3D3563 100 100 LRD3365 — — — 100 100 LRD4365 — — — 100 100 LRD4367 — — — 100 100 23 – 32 D25 – D32 23 – 28 25 – 32 30 – 38 23 – 32 D32 D40A – D65A[4] 30 – 40 17 – 25 23 – 32 D40 – D80[5] 30 – 40 37 – 50 48 – 65 55 – 70 63 – 80 80 – 104 80 – 104 95 – 120 D50 – D80[5] D65 – D80[5] D80 D115 – D150 Ratings apply to circuits with voltages no greater than those listed and are subject to maximum breaker and fuse ampacities. See data bulletin 8536DB0901 for ampacity limitations. [2] When protected by any circuit breaker, including thermal-magnetic and magnetic-only. [3] When protected by any Class J or CC time-delay fuse (Class CC applicable up to 30 A only). [4] Overload relays with Everlink™ termination — direct mount to D40A to D65A only. [5] Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only. [1] Note: This table lists the maximum SCCR of the component when protected by any circuit breaker or fuse. If the maximum component SCCR is 100 kA and a 25 kA rated circuit breaker is used, then the system will be 25 kA as the circuit breaker becomes the weakest link. 3 TeSys™ D-Line Contactors and Starters LR2 and LR3D 3-pole Bimetallic Overload Relays LR2 and LR3D 3-pole Bimetallic Overload Relays Description D-Line 3-pole thermal overload relays are designed to protect ac circuits and motors against overloads, phase failure, long starting times and prolonged stalling of the motor. LRD3322 to 4369, LR2D LRD01 to 35 1 1 6 41 46 3.5 2 0 1 5 STOP 3 50 3 5 37 5 A RESET 2 4 3 R A E S E T M TEST 4 6 4 NO 7 98 NC 97 95 96 1 Adjustment dial Ir 2 Test button Operation of the Test button allows: - checking of control circuit wiring, - simulation of relay tripping (actuates both the N.O. and N.C. contacts). 3 Stop button. Actuates the N.C. contact; does not affect the N.O. contact. 4 Reset button 5 Trip indicator 6 Setting locked by sealing the cover. 7 Selector for manual or automatic reset. Relays LRD01 to LRD35 are supplied with the selector in the manual position, protected by a cover. Deliberate action is required to move it to the automatic position. Environment IEC 60947-1, IEC 60947-4-1, NF C 63-650, VDE 0660, BS 4941 Conforming to standards Product certifications CSA, UL, Sichere Trennung, PTB except LAD4: UL, CSA. Degree of protection Conforming to VDE 0106 Protective treatment Conforming to IEC 60068 Ambient air temperature around the device Protection against direct finger contact IP 2X “TH” Storage °C - 60 to + 70 (- 140 to + 158 °F) Normal operation, without derating (IEC 60947-4-1) °C - 20 to + 60 (- 68 to + 140 °F) Minimum and maximum operating temperatures (with derating) °C - 40 to + 70 (- 104 to + 158 °F) Operating positions without derating In relation to normal, vertical mounting plane Any position Shock resistance Permissible acceleration conforming to IEC 60068-2-7 15 gn - 11 ms Vibration resistance Permissible acceleration conforming to IEC 60068-2-6 Dielectric strength at 50 Hz Conforming to IEC 60255-5 kV 6 Impulse withstand voltage Conforming to IEC 60801-5 kV 6 6 gn Auxiliary Contact Characteristics Conventional rated thermal current A 5 Amps AC; 1 Amp DC V 24 48 110 220 380 600 VA 100 200 400 600 600 600 V 24 48 110 220 440 – W 100 100 50 45 25 – By gG, BS or Class CC fuse. Max. rating or by GB2 circuit-breaker A 5 maximum Flexible cable with cable end One or two conductors AWG (mm2) 18 - 14 (1 - 2.5) Solid cable without cable end One or two conductors AWG (mm2) 18 - 14 (1 - 2.5) Flexible cable without cable end One or two conductors AWG (mm2) 18 - 14 (1 - 2.5) Solid cable without cable end One or two conductors AWG (mm2) 18 - 14 (1 - 2.5) lb-in (N.m) 15 (1.7) ac supply Maximum consumption of operating coils of controlled contactors (Occasional operating cycles of contact 95-96) Short-circuit protection k dc supply Connection to screw clamp terminals Min - max c.s.a. Tightening torque k Select short circuit protection to meet the National Electrical Code or other local codes and standards. Catalog Numbers: pages 134, 135 Dimensions: pages 138 - 140 130 © 2001-2004 Schneider Electric All Rights Reserved 01/04 TeSys™ D-Line Contactors and Starters LR2 and LR3D 3-pole Bimetallic Overload Relays Electrical Characteristics of Power Circuit LRD 01 to 16 Relay type Tripping class Rated insulation voltage (Ui) LR2 D15•• LR3 D01 to D16 To UL 508, IEC 60947-4-1 V LR2 D25•• LRD 3322 to 33696 LR3 D21 to D35 10 Conforming to IEC 60947-4-1 LRD 21 to 35 20 690 10 LRD 4365 to 4369 20 10 LR3 D3322 to D33696 20 10 690 1000 600 600 except LRD4369 V kV 6 6 6 6 Frequency limits Of the operational current Hz 0 to 400 0 to 400 0 to 400 0 to 400 Setting range Depending on model A 0.1 to 13 12 to 38 17 to 104 80 to 140 Flexible cable without cable end One conductor AWG (mm2) 14 - 8 (1.5 - 10) 14 - 8 (1.5 - 10) 10 - 2 (4 35) 10 - 1 (4 - 50) Flexible cable with cable end One conductor AWG (mm2) 16 - 12 (1 - 4) 16 - 10 (1 - 6) except LRD21: 16 - 12 (1 - 4) 10 - 2 (4 35) 10 - 2 (4 - 35) AWG (mm2) 16 - 10 (1 - 6) 14 - 8 (1.5 - 10) except LRD21: 16 - 10 (1 - 6) 12 - 2 (4 35) 10 - 1 (4 - 50) lb-In (N.m) 15.0 (1.7) 22.1 (2.5) 100 lb-in 100 lb-in Connection to screw clamp terminals Solid cable without cable end 600 1000 Conforming to UL, CSA Rated impulse withstand voltage (Uimp) 600 LR2 D35•• Min - max c.s.a. One conductor Tightening torque Connection to spring terminals 16.4 (1.85) Min - max c.s.a. Flexible cable without cable end One conductor AWG (mm2) 14 - 12 (1.5 - 4) – 14 - 12 (1.5 - 4) – – – – Solid cable without cable end One conductor AWG (mm2) 14 - 12 (1.5 - 4) – 14 - 12 (1.5 - 4) – – – – °C °F - 20 to + 60 - 68 to + 140 - 30 to + 60 - 86 to + 140 - 30 to + 60 - 86 to + 140 Operating Characteristics Temperature compensation Tripping threshold Conforming to IEC 60947-4-1 Sensitivity to phase failure Conforming to IEC 60947-4-1 A - 20 to + 60 - 68 to + 140 1.14 ± 0.06 In Tripping current 30% of In on one phase, the others at In Tripping curves Average operating time related to multiples of the current setting Class 10 Hours Minutes Seconds Class 20 Hours 2 1 40 20 20 10 Minutes 4 2 2 1 40 1 40 20 20 10 10 Seconds 1 2 3 1 0.8 0.8 1 2 4 6 10 2 1 0.8 17 20 0.8 1 x times current setting (Ir) 01/04 1 2 3 4 2 Catalog Numbers: pages 134, 135 10 4 4 1 2 3 2 1 40 2 4 6 10 17 20 x times current setting (Ir) Balanced operation, 3-phase, from cold state. Balanced operation, 2-phase, from cold state. Balanced operation, 3-phase, after a long period at the set current (hot state). Dimensions: pages 138 - 140 © 2001-2004 Schneider Electric All Rights Reserved 131 TeSys™ D-Line Contactors and Starters Selection of 3-pole Class 10 Bimetallic Overload Relays Selection of 3-pole Class 10 Bimetallic Overload Relays Differential (Single Phase Sensitive) Thermal Overload Relays Compensated Relays with Manual or Automatic Reset, with Relay Trip Indicator, for ac or dc. By Circuit Breaker Short-circuit Protection for North American Applications By Fuses Fuses to be used with Selected Relay For use with Relay Setting Range Contactor LC1aM gG BS88 A A A Select in Accordance with NEC and Local Codes Maximum 400% of Motor FLA Catalog Number Weight lb. (kg) LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 LRD32 LRD35 LRD3322 LRD3353 LRD3355 LRD3357 LRD3359 LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 LRD33656 (1) LRD33676 (1) LRD33696 (1) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 0.27 (0.124) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.12 (0.510) 1.98 (0.900) 1.98 (0.900) 1.98 (0.900) 2.20 (1.000) 2.20 (1.000) 2.20 (1.000) A Class 10 with Connection by Screw Clamp Terminals LRD08 LRD21 LRD33 0.10 to 0.16 0.16 to 0.25 0.25 to 0.40 0.40 to 0.63 0.63 to 1 1 to 1.6 1.6 to 2.5 2.5 to 4 4 to 6 5.5 to 8 7 to 10 9 to 13 12 to 18 16 to 24 23 to 32 30 to 38 17 to 25 23 to 32 30 to 40 37 to 50 48 to 65 55 to 70 63 to 80 80 to 104 80 to 104 95 to 120 110 to 140 80 to 104 95 to 120 110 to 140 0.25 0.5 1 1 2 2 4 6 8 12 12 16 20 25 40 50 25 40 40 63 63 80 80 100 125 125 160 100 125 160 2 2 2 2 4 4 6 10 16 20 20 25 35 50 63 80 50 63 100 100 100 125 125 160 200 200 250 160 200 250 – – – – – 6 10 16 16 20 20 25 32 50 63 80 50 63 80 100 100 125 125 160 160 200 200 160 200 200 D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D12 to D38 (2) D18 to D38 (2) D25 to D38 (2) D25 to D38 (2) D32 and D38 (2) D40 to D95 D40 to D95 D40 to D95 D40 to D95 D50 to D95 D50 to D95 D65 to D95 D80 and D95 D115 and D150 D115 and D150 D150 D115 and D150 D115 and D150 D115 and D150 Class 10 with Spring Terminal Connections (for direct mounting on the contactor only) LRD083 0.10 to 0.16 0.16 to 0.25 0.25 to 0.40 0.40 to 0.63 0.63 to 1 1 to 1.6 1.6 to 2.5 2.5 to 4 4 to 6 5.5 to 8 7 to 10 9 to 13 12 to 18 16 to 24 0.25 0.5 1 1 2 2 4 6 8 12 12 16 20 25 2 2 2 2 4 4 6 10 16 20 20 25 35 50 – – – – – 6 10 16 16 20 20 25 32 50 D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D09 to D38 (2) D12 to D38 (2) D18 to D38 (2) D25 to D38 (2) LRD013 LRD023 LRD033 LRD043 LRD053 LRD063 LRD073 LRD083 LRD103 LRD123 LRD143 LRD163 LRD213 LRD223 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) 6.31 (0.140) Class 10 with Ring-Tongue Terminals for LRD01 through LRD35 (load side terminals only) Select the appropriate overload relay with screw clamp terminals from the table above and add 6 to the end of the reference. Example: LRD01 becomes LRD016. Thermal Overload Relays for use on single phase loads Class 10 with connection by screw clamp terminals Change the prefix in the references above from LRD (except LRD4kkk) to LR3D. Example: LRD01 becomes LR3D01. Thermal Overload Relays for use on 1000 V Supplies Class 10 with connection by screw clamp terminals For relays LRD-01 to LRD-35 only, for an operating voltage of 1000 V, and only for independent mounting, the reference becomes LRD33 A66. Example: LRD12 becomes LRD3312A66. Order an LA7D3064 terminal block separately; see page 137. (1) These are special separate mounted versions of the LRD43 overload relays for the LC1D115 and D150 contactors. Part number includes overload relay, terminal block and 6 connectors (unit is not UL/CSA approved). (2) When used with D25-D38 contactors, order spacer clip (part number W816366180111). See page 137. 134 © 2001-2004 Schneider Electric All Rights Reserved 01/04