Pierlite Australia Pty Ltd
ABN 71 115 184 999
96-112 Gow Street
Padstow NSW 2211
PO Box 314, Padstow
Telephone +61 2 9794 9300
Facsimile +61 2 9707 4190 lighting@pierlite.com.au
www.pierlite.com
Type of Protection:
IP Rating:
Class 1 Luminaire
IP20
Nominal Voltage:
Nominal Frequency (Hz):
230-240V
50
Rated Maximum Ambient Temperature: 35°C
N204
Suitable for direct mounting on flammable surfaces.
The C-Tick marking of this product applies to AS/NZS
CISPR15:2002 “Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment”
This product is designed to conform to AS/NZS60598
“Luminaires, general requirements and tests”
General purpose linear fluorescent troffer available in T-bar, plaster and surface mounting versions. A range of diffuser types are available to suit different applications.
Luminaires are to be stored in cool dry conditions preventing ingress of moisture and condensation
This product when operated under normal use shall provide years of service with minimal or no maintenance needed. However, care is expected in installing this product.
The health and safety requirements of Workcover shall be met.
Handling and electrical work associated with this product is to be in accordance with AS/NZS3000:2000 “Australian/New
Zealand wiring rules”
The luminaires are Class 1 and should be effectively earthed.
Certification details on the rating plate must be verified against the application requirements before installation. The information in this leaflet is correct at the time of publication. The company reserves the right to make specification changes as required.
5.1 Tool requirements
Installation tools may include a 3mm flat blade insulated screwdriver, insulated pliers, knife and wire strippers or cutters.
5.2 Electrical Supplies
Always ensure the correct supply voltage is as the rating label on the product. Slight variations of the nominal line voltage within the range of +6%/-6% are expected, although luminaires should not be operated continuously at more than +6%/-10% of the rated supply voltage of the control gear.
5.3 Lamps
All lamps used are of a standardised type, as stated on the rating label. Do not replace lamps with different wattages or types other than indicated on the rating label. There are no preferences between make and colour, unless specified on the rating label.
Care must be taken to fit the correct replacement lamp in order to preserve the certification conditions and obtain the designed photometric performance. Lamps should be replaced shortly after they do not light.
On twin T5 lamp luminaires, always place the lamp labels at the same end of the fitting.
For dimming ballasts – run lamps at 100% for 100 hours before dimming.
5.4 Mounting
Luminaires should be installed where access for maintenance is practical and in accordance with any lighting design information provided for the installation.
5.5 Installing T-bar luminaries FSN...
a) All T-bar luminaires are fitted with a flex and plug.
b) Lift luminaire into ceiling cavity, insert plug into power socket.
c) Lower luminaire onto T-bar rails and centralize the fitting.
d) SRS reflector fittings are supplied with a protective film, this
MUST be removed before powering the luminaire.
e) Insert diffuser diagonally through the aperture and curve it likely as required.
5.6 Installing Plaster luminaries FSP……
Plaster recessed luminaries come supplied with a Plaster Master frame.
a) Separate the frame from the body of the luminaire.
b) Cut out the correct hole size for your fitting.
c) Fit the Plaster Master frame as per the instructions supplied.
d) Insert the luminaire diagonally into aperture and lower it down flat onto the inside face of the frame.
e) Insert diffuser diagonally through the aperture and curve it likely as required.
Version 1.0 03/09