MINIATURE CIRCUIT BREAKER Electrical distribution needs are continuously evolving in residentional, commercial and Industrial sectors. Improved operational safety, continuity of service, greater convenience and operating cost have assumed a tremendous significance. Miniature circuit breakers have been designed to continuously adapt to these changing needs. Range 6A to 40A "B" Curve 0.5A to 63A "C" Curve 0.5A to 63A for "DC" Application Execution Single Pole (1P) Single Pole & Neutral (1P+N) Double Pole (2P) Three Pole (3P) Three Pole & Neutral (3P+N) Four Pole (4P) • UNIFORM 10KA BREAKING CAPACITY FOR "B" AND "C" CURVE Specification • LOW POWER CONSUMPTION, THUS COST EFFECTIVE & ENERGY SAVING IEC/EN 60898 • SUITABLE FOR DC AND FOR A WIDE FREQUENCY RANGE OF 50Hz-400Hz APPLICATION Feature • "FINGER SAFE" TERMINALS-IP20 DEGREE OF PROTECTION • ARC CHUTE FOR EFFECTIVE ARC QUENCHING • SILVER GRAPHITE CONTACTS FOR ENHANCED LIFE • Precise hammer action • 15 Plates Arc Chute for effective arc quenching • Longer electrical life • Wide range • Value for money • Low power consumption, thus cost effective & energy saving Accessories Auxiliary Switch Shunt trip 3 MINIATURE CIRCUIT BREAKER HOUSING: • The housing of Decovolt MCB is Injection Moulded from special grade PBT as per international specifications. • The housing and other moulded components are fire retardant, anti-tracking and non hygroscopic. • The Housing can withstand high temperature and is impact resistant. CONTACTS: Contacts are made of special silver inlaid into copper strip, ensuring higher life and maximum safety against contact welding and erosion. These contacts have low contact resistance resulting into low watt loss. CURRENT LIMITING ACTION: The high speed current limiting action ensures that the MCB operate before the full prospective fault current is allowed to develop. Under fault conditions, damage can be sustained to the installation and associated equipment due to the amount of energy that passes before the current is completely interrupted. The total energy let through depends on the value of current and the time for which it flows. The high speed current limiting action of DECOVOLT MCB ensures that the energy let through and any subsequent damage is minimized. This reduced LET THROUGH ENERGY (Class 3 as per BSEN 60898) assists greatly with both backup and discrimination considerations. OPERATING MECHANISM: DECOVOLT MCB have a quick make and break trip free mechanism. In the event of an over current or short circuit the MCB automatically interrupts all poles even if the MCB toggle is held in ON position, the handle always indicates the correct contact position. MODERATE Internal View of MCB OVERLOAD CONDITION: Detection of moderate Over load conditions is achieved by the use of a Bimetal Overload Relay, Outgoing Terminal which deflects in response to the current passing Body through it The Bimetal Relay moves against the trip bar releasing the trip mechanism. Latch Arc-chutes Holder Solenoid Arc-chutes Arc-runner Arc-chutes Holder SHORT CIRCUIT CONDITIONS: When the current flowing through the MCB reaches a predetermined level, the solenoid in Magnetic coil directly pulls in the plunger, which releases the trip mechanism. Moving Contact Arm Fixed Contact PERFECT CONECTIONS: The design of terminals makes the wiring easier. A combination box type Incoming Terminal (Dual Termination) terminal with combination head screws on both sides with deep serrations ensures sparkles and firm connections. 4 MINIATURE CIRCUIT BREAKER TECHNICAL INFORMATION TITLE MCB STANDARD CONFORMITY IEC 60898:2002 TYPE/SERIES ISOLATOR IEC 60947-3:2001 B C B 6-40* 6-40* 6-40* 240/415 240/415 240/415 RATED FREQUENCY (f) 50 50 50 Nos of Poles (Execution) 1P,1P+N,2P,3P,3P+N,4P 1P,1P+N,2P,3P,3P+N,4P 1P,1P+N,2P,3P,3P+N,4P 10 10 10 (3-5) In (3-5) In (3-5) In 660 660 660 4 4 4 LESS THAN 32 Amps 20000 20000 20000 MORE THAN 32 Amps 10000 10000 10000 - 5 to + 55 - 5 to + 55 - 5 to + 55 25 25 25 3 3 3 40MM FREE FALL 40MM FREE FALL 40MM FREE FALL IP 20 IP 20 IP 20 RATED CURRENT (In) RATED VOLTAGE (AC) (Ue) RATED SHORT CIRCUIT BREAKING CAPACITY Ka UTILIZATION CATEGORY MAGNETIC RELEASE SETTING RATED INSULATION VOLTAGE(Ui) RATED IMPULSE VOLTAGE (Uimp) ELECTRICAL / MECHANICAL ENDURANCE AMBIENT TEMPERATURE TERMINAL CAPACITY (MAX) sq.mm VIBERATION g SHOCK PROTECTION CLASS INSTALLATION POSITION MOUNTING CASE & COVER VERTICAL/ HORIZONTAL CLIP ON DIN RAIL VERTICAL/ HORIZONTAL VERTICAL/ HORIZONTAL CLIP ON DIN RAIL CLIP ON DIN RAIL MOULDED, FLAME RETARDANT THERMOPLASTIC MATERIAL * CURRENT RATINGS - 0.5, 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63 "B" CURVE MCB's ARE AVAILABLE ON REQUEST ** 1P SINGLE POLE 1P+N SINGLE POLE NEUTRAL 2P DOUBLE POLE 3P THREE POLE 3P+N THREE POLE NEUTRAL 4P FOUR POLE 5 MINIATURE CIRCUIT BREAKER SELECTION Fresh hold application APPLIANCES AIR CONDITIONER REFRIGATOR OVEN/GRILLER OVEN/GRILLER HOT PLATE ONLY ROOM HEATER WASHING MACHINE WASHING MACHINE WITH HEATER WATER HEATER STORAGE / INSTANT ELECTRIC IRON AUTO TOASTER ( 2 SLICES) ELECTRIC KETTLE CAPACITY/WATT (Load)(240V-1pH) 1.0 tonnes 1.5 tonnes 2.0 tonnes 165 litres 350 litres 4500 W 1750 W 750W 2000W 1000W 2000W 300W CURRENT RATING OF MCB 10A 16A 20A 3A 4A 32A 10A 6A 10A 6A 10A 2A TYPE OF MCB "C" SERIES "C" SERIES "C" SERIES "C" SERIES "C" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "C" SERIES 1300W 1000W 2000W 3000W 6000W 750W 1250W 1200W 1500W 8A 6A 10A 16A 32A 6A 8A 8A 10A "C" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES "B" SERIES Lamp Watt 20W No of lamps 8 12 Rating (A) 1 1.5 40W 2 10 12 1 4 8 12 1 2 5 8 12 0.5 2 2.5 0.5 1.5 3 4 0.5 1 2 4 5 60W 80W 100W S.NO KW HP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 3.75 5.5 7.5 10 15 18.5 22 30 0.24 0.34 0.5 0.74 1.01 1.47 2.01 2.95 4.02 5.03 7.37 10.05 13.4 20.11 24.8 29.49 40.21 3 PHASE 400V DOL STARTING FULL LOAD MCB CURRENT SELECTION C 0.9 2 1.2 2 1.2 2 1.8 3 2 3 2.6 6 3.5 10 4.4 10 6.3 16 8.2 20 11.2 25 14.4 40 21 50 27 100 32 125 38 125 51 125 3 PHASE 400V ASSISTED STARTING STAR DELTA MCB FULL LOAD CURRENT SELECTION C D 6.3 16 10 8.2 20 10 11.2 32 16 14.4 40 25 21 50 32 27 63 40 32 50 38 63 51 63 NOTE: One lighting circuit can have up to 800W or up to 10 lighting points One power circuit can have up to 2000W or 1 power point 6 1 1.5 2.5 " B " series MCB is used for lighting applications SELECTION OF MCB FOR MOTOR PROTECTION 1 PHASE 230V DOL STARTING MCB FULL LOAD CURRENT SELECTION C 2.8 10 3.2 10 3.5 10 4.8 16 6.2 20 8.7 25 11.8 32 17.5 50 20 63 24 80 26 80 47 125 - 1 2 4 MINIATURE CIRCUIT BREAKER TRIPPING CHARACTERSTICS CURVES Tripping Characterstics Curve Type B & C 10000 5000 3600 10000 5000 3600 Limit Specified in IEC-60898-1-2002 In : Rated Current B Type - 0.5A to 100A C Type - 0.5A to 100A Lower Limit as per Standard Upper Limit as per Standard 1000 Tripping Characterstics Curve DC MCB Type B & C Upper Limit as per Standard 1000 Reference Calibration Temp-30˚C Time in Seconds In < 32A 10 In > 32A 100 In < 32A 10 1 1 B-Type B-Type C-Type C-Type 0.1 0.1 0.01 11.131.45 2 2.55 3 5 10 14 20 28 Multiple of Rated Current 50 Decovolt MCB Vs Zero Point Extinguishing MCB U/V 0.01 11.131.45 2 2.55 3 5 10 14 20 28 Multiple of Rated Current 50 Temperature Compensation Graph 60 50 Current Limiting 40 Ambient Temp.˚C Time in Seconds Reference Calibration Temp-30˚C In > 32A 100 Limit Specified in IEC-60898-1-2002 In : Rated Current B Type - 0.5A to 100A C Type - 0.5A to 100A Lower Limit as per Standard U/V 30 20 MCB U/V 10 0 -10 Zero point Extinguishing MCB Un = Mains Voltage ID = Let - through short circuit current 0.7 UB = Arc Voltage Ip = Prospective short circuit current 0.6 0.9 1.0 1.1 Correction Factor 1.2 1.3 1.4 ˚ Reference Calibration Temp. 30 C 7 MINIATURE CIRCUIT BREAKER SINGLE POLE SINGLE POLE - N DOUBLE POLE 8 CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 "B CURVE" CAT NO DVBSP105 DVBSP1001 DVBSP1002 DVBSP1003 DVBSP1004 DVBSP1005 DVBSP1006 DVBSP1010 DVBSP1016 DVBSP1020 DVBSP1025 DVBSP1032 DVBSP1040 DVBSP1050 DVBSP1063 CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 "C" CURVE CAT NO DVCSP105 DVCSP1001 DVCSP1002 DVCSP1003 DVCSP1004 DVCSP1005 DVCSP1006 DVCSP1010 DVCSP1016 DVCSP1020 DVCSP1025 DVCSP1032 DVCSP1040 DVCSP1050 DVCSP1063 "C" CURVE CAT NO DVASP105 DVASP1001 DVASP1002 DVASP1003 DVASP1004 DVASP1005 DVASP1006 DVASP1010 DVASP1016 DVASP1020 DVASP1025 DVASP1032 DVASP1040 DVASP1050 DVASP1063 "B CURVE" CAT NO DVBDP105 DVBDP1001 DVBDP1002 DVBDP1003 DVBDP1004 DVBDP1005 DVBDP1006 DVBDP1010 DVBDP1016 DVBDP1020 DVBDP1025 DVBDP1032 DVBDP1040 DVBDP1050 DVBDP1063 "C" CURVE CAT NO DVCDP105 DVCDP1001 DVCDP1002 DVCDP1003 DVCDP1004 DVCDP1005 DVCDP1006 DVCDP1010 DVCDP1016 DVCDP1020 DVCDP1025 DVCDP1032 DVCDP1040 DVCDP1050 DVCDP1063 MINIATURE CIRCUIT BREAKER THREEE POLE THREEE POLE - N DOUBLE POLE CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 "B CURVE" CAT NO DVBTP105 DVBTP1001 DVBTP1002 DVBTP1003 DVBTP1004 DVBTP1005 DVBTP1006 DVBTP1010 DVBTP1016 DVBTP1020 DVBTP1025 DVBTP1032 DVBTP1040 DVBTP1050 DVBTP1063 CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 CURRENT RATING (A) 0.5 1 2 3 4 5 6 10 16 20 25 32 40 50 63 "C" CURVE CAT NO DVCTP105 DVCTP1001 DVCTP1002 DVCTP1003 DVCTP1004 DVCTP1005 DVCTP1006 DVCTP1010 DVCTP1016 DVCTP1020 DVCTP1025 DVCTP1032 DVCTP1040 DVCTP1050 DVCTP1063 "C" CURVE CAT NO DVATP105 DVATP1001 DVATP1002 DVATP1003 DVATP1004 DVATP1005 DVATP1006 DVATP1010 DVATP1016 DVATP1020 DVATP1025 DVATP1032 DVATP1040 DVATP1050 DVATP1063 "B CURVE" CAT NO DVBFP105 DVBFP1001 DVBFP1002 DVBFP1003 DVBFP1004 DVBFP1005 DVBFP1006 DVBFP1010 DVBFP1016 DVBFP1020 DVBFP1025 DVBFP1032 DVBFP1040 DVBFP1050 DVBFP1063 "C" CURVE CAT NO DVCFP105 DVCFP1001 DVCFP1002 DVCFP1003 DVCFP1004 DVCFP1005 DVCFP1006 DVCFP1010 DVCFP1016 DVCFP1020 DVCFP1025 DVCFP1032 DVCFP1040 DVCFP1050 DVCFP1063 9