miniature circuit breakers

advertisement
MINIATURE
CIRCUIT BREAKERS
MCB
C
M
B
Contents
www.sigmaelektrik.com
4
General Information..............................................................
1
3 kA Miniature Circuit Breakers..............................................
2
4.5 kA Miniature Circuit Breakers...........................................
3
6 kA Miniature Circuit Breakers..............................................
4
10 kA Miniature Circuit Breakers............................................
5
16 kA Miniature Circuit Breakers ...........................................
6
Installation.............................................................................
7
Normal Service Conditions ..................................................
7
Tripping Charactectics And Selection ..................................
8
Protection Of The DC Circuits................................................
9
Influence Of Non-Standard Fruquencies...............................
9
Power Loss.............................................................................
9
Protection Of Motors.............................................................
10
Protection Of The Lighting Circuits.........................................
11
MCB Accessories...................................................................
13
Dimensions Of MCB...............................................................
14
Order Information..................................................................
15
MINIATURE
CIRCUIT BREAKERS
MCB
General Information
Sigma MCBs are such devices that protect their connected circuits against short circuit and overload.
Sigma MCBs produced as 3 kA, 4.5 kA, 6 kA, 10 kA and 16kA according to the EN 60898-1, EN 60947-2 and VDE 0660.
They are also conforming to the Low Voltage Directive (LVD) 73/23/EEC.
1
2
3
4
5
3 kA MCB
4.5 kA MCB
6 kA MCB
10 kA MCB
6
7
7
8
9
9
9
10
11
13
14
15
Handle
Tripping mechanism
Magnetic coil
Connection terminals
Fixed contact
Bi-metal
Arc Extinguisher
The main components that make up a miniature circuit breaker
www.sigmaelektrik.com
1
MINIATURE
CIRCUIT BREAKERS
MCB
3 kA Miniature Circuit Breakers
Technical Specifications
Type
SND 3000
No Of Poles
1
Rated Current (at 30 °C)
2
3
4
A
2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
AC (V)
240/415
Rated Voltage
Ue
Rated Insulation Voltage
AC (V)
Rated Impulse Voltage
Uimp
kV
6
Rated Breaking Capacity
Icn
kA
3
690
Selectivity Class
3
Electrical Life
ope.
Mechanical Life
ope.
230 V
6.000
20.000
Protection Class
IP 20
Ambient Operating
Temperature
o
C
between -5 and +40
Storage
Temperature
o
C
between -40 and +55
Colour
RAL 7035
Assembly (EN 60715)
35 mm DIN Rail
Connection Capacity
(min - max)
mm2
1-25
Max. Tightenning
Torque
Nm
2
Tripping Characteristics
10.000
5.000
1h
2.000
1.000
500
10.000
5.000
1h
2.000
1.000
500
200
200
100
50
100
50
20
10
5
20
10
5
t(s)
t(s)
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.2
0.1
0.05
0.02
0.01
0.005
0.005
0.002
0.001
0.5
0.002
0.001
0.5
1
2 3 4 5 7 10
XIn
B Curve
www.sigmaelektrik.com
2
2
1
0.5
20 30 50 70 100
200
1
2 3 4 5 7 10
XIn
C Curve
20 30 50 70 100
200
MINIATURE
CIRCUIT BREAKERS
MCB
4.5 kA Miniature Circuit Breaker
Technical Specifications
Type
SND 4500
No Of Poles
1
Rated Current (at 30 °C)
2
3
4
A
2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Rated Voltage
Ue
AC (V)
240/415
Rated Insulation Voltage
Ui
V
690
Rated Impulse Voltage
Uimp
kV
6
Rated Breaking Capacity
Icn
kA
4.5
Selectivity Class
3
Electrical Life
ope.
Mechanical Life
ope.
230 V
6.000
20.000
Protection Class
IP 20
Ambient Operating
Temperature
o
C
between -5 and +40
Storage
Temperature
o
C
between -40 and +55
Colour
RAL 7035
Assembly (EN 60715)
35 mm DIN Rail
Connection Capacity
(min - max)
mm2
1-25
Max. Tightenning Torque
Nm
2
Tripping Characteristics
t(s)
10.000
5.000
1h
2.000
1.000
500
10.000
5.000
1h
2.000
1.000
500
200
200
100
50
100
50
20
10
5
20
10
5
t(s)
2
1
0.5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.2
0.1
0.05
0.02
0.01
0.005
0.005
0.002
0.001
0.5
0.002
0.001
0.5
1
2 3 4 5 7 10
XIn
B Curve
20 30 50 70 100
200
1
2 3 4 5 7 10
XIn
20 30 50 70 100
200
C Curve
www.sigmaelektrik.com
3
MINIATURE
CIRCUIT BREAKERS
MCB
6 kA Miniature Circuit Breaker
Technical Specifications
Type
SND 6000
No Of Poles
1
Rated Current (at 30 °C)
2
3
4
1
2
3
A
2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
80, 100, 125
415
415
Rated Voltage
Ue
AC (V)
Rated Insulation Voltage
Ui
V
690
Rated Impulse Voltage
Uimp
kV
6
Rated Breaking Capacity
Icn
kA
6
Selectivity Class
4
3
Electrical Life
ope.
Mechanical Life
ope.
230 V
6.000
2.000
20.000
10.000
Protection Class
IP 20
Ambient Operating
Temperature
o
C
between -5 and +40
Storage
Temperature
o
C
between -40 and +55
Colour
RAL 7035
Assembly (EN 60715)
35 mm DIN Rail
Connection Capacity
(min - max)
mm2
1-25
1-50
Max. Tightenning
Torque
Nm
2
3.5
Tripping Characteristics
10000
6000
4000
3600
2000
1000
600
400
10000
6000
4000
3600
2000
1000
600
400
10000
6000
4000
3600
2000
1000
600
400
200
100
60
40
200
100
60
40
200
100
60
40
20
10
6
4
20
10
6
4
20
10
6
4
t(s)
t(s)
2
1
0,6
0,4
0,2
t(s)
2
1
0,6
0,4
0,2
2
1
0,6
0,4
0,2
0,1
0,1
0,1
0,04
0,02
0,04
0,02
0,04
0,02
0,01
0,004
1
1,5 2
1,13
1,45
3
www.sigmaelektrik.com
4
4
6
8 10
xln
B Curve
15 20 30 40
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
xln
C Curve
15 20 30 40
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
xln
D Curve
15 20 30 40
MINIATURE
CIRCUIT BREAKERS
MCB
10 kA Miniature Circuit Breaker
Technical Specifications
Type
SND 10000
No Of Poles
1
Rated Current (at 30 °C)
2
3
4
1
2
3
A
2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
80, 100, 125
415
415
Rated Voltage
Ue
AC (V)
Rated Insulation Voltage
Ui
V
690
Rated Impulse Voltage
Uimp
kV
6
Rated Breaking Capacity
Icn
kA
10
Selectivity Class
4
3
Electrical Life
ope.
Mechanical Life
ope.
230 V
6.000
2.000
20.000
10.000
Protection Class
IP 20
Ambient Operating
Temperature
o
C
between -5 and +40
Storage
Temperature
o
C
between -40 and +55
Colour
RAL 7035
Assembly (EN 60715)
35 mm DIN Rail
Connection Capacity
(min - max)
mm2
1-25
1-50
Max. Tightenning
Torque
Nm
2
3.5
Tripping Characteristics
10000
6000
4000
3600
2000
1000
600
400
10000
6000
4000
3600
2000
1000
600
400
10000
6000
4000
3600
2000
1000
600
400
200
100
60
40
200
100
60
40
200
100
60
40
20
10
6
4
20
10
6
4
20
10
6
4
t(s)
t(s)
2
1
0,6
0,4
0,2
t(s)
2
1
0,6
0,4
0,2
2
1
0,6
0,4
0,2
0,1
0,1
0,1
0,04
0,02
0,04
0,02
0,04
0,02
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
xln
B Curve
15 20 30 40
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
xln
C Curve
15 20 30 40
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
15 20 30 40
xln
D Curve
www.sigmaelektrik.com
5
MINIATURE
CIRCUIT BREAKERS
MCB
16 kA Miniature Circuit Breaker
Technical Specifications
Type
SND 16000
No Of Poles
1
Rated Current (at 30 °C)
Rated Voltage
Ue
Rated Voltage
A
40, 50, 63, 80, 100, 125
AC (V)
415
DC (V)
60
Rated Insulation Voltage
Ui
V
690
Rated Impulse Voltage
Uimp
kV
6
Rated Breaking Capacity
Ics
kA
16
Selectivity Class
3
Electrical Life
ope.
Mechanical Life
ope.
230 V
2.000
10.000
Protection Class
IP 20
Ambient Operating
Temperature
o
C
between -5 and +40
Storage
Temperature
o
C
between -40 and +55
Colour
RAL 7035
Assembly (EN 60715)
35 mm DIN Rail
Connection Capacity
(min - max)
mm2
2.5 - 50
Tightenning
Torque
Nm
3
Tripping Characteristics
10000
6000
4000
3600
2000
1000
600
400
10000
6000
4000
3600
2000
1000
600
400
200
100
60
40
200
100
60
40
20
10
6
4
20
10
6
4
t(s)
t(s)
2
1
0,6
0,4
0,2
2
1
0,6
0,4
0,2
0,1
0,1
0,04
0,02
0,04
0,02
0,01
0,004
1
1,5 2
1,13
1,45
3
www.sigmaelektrik.com
6
4
6
8 10
xln
C Curve
15 20 30 40
0,01
0,004
1
1,5 2
1,13
1,45
3
4
6
8 10
xln
D Curve
15 20 30 40
MINIATURE
CIRCUIT BREAKERS
MCB
Installation
Up to 25 mm2 cable can be connected to the sigma MCBs, which are designed
to be easily mounted on to the 35 mm DIN rail according to EN 50022. Besides,
connection with collective MCB Bus bar is possible. Maximum torque applied
for connection screws is 2 Nm. Higher torque may damage to the screws or
terminal connections.
Although Sigma MCBs have availability to make energy entrance from both
upper side and under side, it is recommended to make from upper side.
Connection Terminals own IP20 protection degree according to the EN60529.
The Design that has IP20 protection degree
properties for safe to touch.
Sealable properties
DIN Rail Specifications should be suitable according to EN50022.
Normal Service Conditions
Sigma MCBs are designed to operate at ambient temperatures between -5 oC and +40 oC. The calibration temperature is 30 oC. If ambient temperature value
is different than 30 oC, please use below table to compansate tripping time. The upper limit for relative humidity is 50% at a maximum temperature of +40 oC,
although the breakers can operate at higher relative humidities for lower temperatures (e.g.: a relative humidity of the 90% at +20 oC ambient temperature
would be acceptable).
Sigma MCB specification throughout this catalogue are for installations where the altitude does not exceed 2000m above sea level. For installations above
at higher altitudues, it is necessary to take into account the reduction of the dielectric strength and of the cooling effect of the air. The ambient temperature
during transport and storage must not exceed the interval between -40 oC and +55 oC. For short periods not exceeding 24 hour up to +70 oC can be reached
with a relative humidity of 30%. During this period it is important to avoid water condensation in side the breakers, otherwise, oxidation and stain spots might
appear affecting thus the normal operation of the breaker.
Influence Of Ambient Temperature On Nominal Currents
In [A] / C
-10
0
10
20
30
35
40
45
50
55
60
2
2.3
2.2
2.2
2.1
2
2
1.9
1.9
1.9
1.8
1.8
4
4.7
4.5
4.3
4.2
4
3.9
3.9
3.8
3.7
3.6
3.5
6
7
6.7
6.5
6.3
6
5.9
5.8
5.7
5.6
5.4
5.3
10
12
11
11
10
10
9.9
9.7
9.5
9.4
9
8.9
16
19
18
17
17
16
16
15
15
15
14
14
20
23
22
22
21
20
20
19
19
19
18
18
25
29
28
27
26
25
25
24
24
23
23
22
32
37
36
35
33
32
32
31
30
30
29
28
40
47
45
43
42
40
39
39
38
37
36
35
50
58
56
54
52
50
49
48
47
46
45
44
63
73
71
68
66
63
62
61
60
58
57
56
O
www.sigmaelektrik.com
7
MINIATURE
CIRCUIT BREAKERS
MCB
minute
minute
Second
Second
minute
Second
Tripping Characteristics And Selection
Application Selection For MCB Tripping Characteristics
I
1
I
2
I
3
I
4
Thermal Non Tripping Current
Type B characteristics are suitable for moderately inductive loads having that have
little or no switching surges i.e. electric heating, water heating, ovens etc.
Thermal Tripping Current
Type C characteristics MCBs can be used in general applications such as lighting,
ring/radial socket outlets and small motors.
Magnetic Non-tripping
Installations where the equipment is likely to produce abnormally high inrush currents, such as transformers, welding machines or induction motors are suited to
type D characteristic.
Magnetic Tripping Current
Magnetic Tripping
Characteristic
Rated
Current (In)
Test
Current
Tripping
Time
Result
Rated
Current (In)
Test
Current
Tripping
Time
Result
B
All
3 In
t ≥ 0.1 sec.
not tripped
In ≤ 63 A
1.13 In
t ≥ 1 hour
not tripped
B
All
5 In
t < 0.1 sec.
tripped
In > 63 A
1.13 In
t ≥ 2 hour
not tripped
C
All
5 In
t ≥ 0.1 sec.
not tripped
In ≤ 63 A
1.45 In
t < 1 hour
tripped
C
All
10 In
t < 0.1 sec.
tripped
In > 63 A
1.45 In
t < 2 hour
tripped
D
All
10 In
t ≥ 0.1 sec.
not tripped
In ≤ 32 A
2.55 In
1 sec. < t < 60 sec.
tripped
D
All
20 In
t < 0.1 sec.
tripped
In > 32 A
2.55 In
1 sec. < t < 120 sec.
tripped
Magnetic Tripping Conditions
www.sigmaelektrik.com
8
Thermal Tripping Conditions
MINIATURE
CIRCUIT BREAKERS
MCB
Protection Of The DC Circuits
The thermal characteristics for Sigma MCBs are unaffected by the type of current applied, that is either direct current or alternating current. The
magnetic trip value increases by 40%. For example, in the case of a breaker of tripping characteristics B and 10A rated current, its magnetic tripping
value will be between 30A and 50A in alternating current. The magnetic tripping value for the same breaker in direct current will be between 42.4A
and 70.7A
For DC service, the MCBs full rated breaking capacity can be achieved without any reduction in performance by connecting protected poles in series.
For values up to 48V=1 protected pole can be used unpaired of the breaking capacity value. Between 48 and 110V=2 protected poles series connected
can be used without reduction in the breaking capacity. Between 110 and 150V=, 3 protected poles series connected must be used, and 4 poles up
to 200V=
Magnetic
Tripping
Curve
Magnetic
Tripping Value
For AC Circuits
Magnetic
Thermal
Tripping Value Tripping Value
For DC Circuits For AC Circuits
B
3-5
4-7
> 1.45xIn
C
5 - 10
7 - 14
D
10 - 20
14 - 28
Magnetic
Tripping Value
For DC circuits
Short-Circuit Breaking Capacity (kA)
Instantaneous
Tripping
1P
2P
3P
4P
> 1.45xIn
≤ 48 V
6
6
10
10
> 1.45xIn
> 1.45xIn
110 V
6
6
10
> 1.45xIn
> 1.45xIn
220 V
10
Influence Of Non-Standard Frequencies
For operational frequencies greater than 50/60Hz, the effect of these non-standard frequencies must be taken into consideration. Thermal characteristics are independent from variation in frequency. Magnetic tripping values are directly affected by frequency. As a reference, for frequencies of 100, 200,
300 and 400Hz, the values at which the magnetic tripping occurs become increased in a 10, 20, 30 and 40% respectively.
Frequency Hz.
Magnetic Tripping Value
B
C
D
17 - 60
3-5
5 - 10
10 - 20
100
3.3 - 5.5
5.5 - 11
11 - 22
Frequency Hz.
Magnetic Tripping Value
B
C
D
200
3.6 - 6
6 - 12
12 - 24
400
4.5 - 7
7.5 - 15
15 - 30
Power Loss
Sigma MCBs have been designed to lose minimum power in their connected circuits and their power loss per pole is much less than the value stated
in EN 60898-1 standards.
Rated
Current
In (A)
Measured Maximum
Power Loss Per Pole At The
Sigma MCB (W)
Should Be The
Maximum Power Loss
According To The
EN 60898-1
Rated
Current
In (A)
Measured Maximum
Power Loss Per Pole At The
Sigma MCB (W)
Should Be The
Maximum Power Loss
According To The
EN 60898-1
2
0.74
3
25
2.3
4.5
6
1
3
32
4
6
10
2.1
3
40
4.9
7.5
16
2.5
3.5
50
5.11
9
20
3
4.5
63
5.8
13
www.sigmaelektrik.com
9
MINIATURE
CIRCUIT BREAKERS
MCB
Protection Of Motors
The protection of motors against the effects of an internal short circuit must be ensured, allowing at the same time the presence of short duration
overcurrents (starting) without causing tripping of the protection element.
This element must also ensure protection of the line, of the contactor and of the thermal relay associated to the motor.
220-240 V Single Phase Induction Motor
Rated Power
Miniature Circuit Breaker
Rated Current (A)
Starting Current (A)
Tripping Curve
Rated Current(A)
0.25
1.5
18
C or D
6
0.5
3
36
C or D
6
0.55
0.75
4.5
54
D
6
0.75
1
5.5
66
C or D
10
kW
Hp
0.18
0.37
1.1
1.5
8.5
102
D
10
1.5
2
10.5
126
C or D
16
2.2
3
15.5
186
D
20
3
4
20
240
D
32
3.75
5
24
288
D
32
5.5
7.5
34
408
D
40
7.5
10
45
540
D
63
400-415 V Three-Phase Induction Motor
Rated Power
Starting Current (A)
Tripping Curve
Rated Current(A)
0.7
8.4
C
6
1.35
16.2
C
6
1.55
18.6
C
6
1
1.93
23.2
C
6
1.5
2.5
30
C
6
3.5
42
C or D
6
kW
Hp
0.18
0.25
0.37
0.5
0.55
0.75
0.75
1.1
1.5
2
Rated Current (A)
Miniature Circuit Breaker
2.2
3
4.8
57.6
D
6
3
4
6.4
76.8
D
10
3.75
5
7.8
93.6
D
10
5.5
7.5
11
132
D
16
7.5
10
14.4
172.8
D
16
9.33
12.5
17.3
207.6
D
20
11
15
21
252
D
25
15
20
28
336
D
32
18.5
25
35
420
D
40
22
30
40
480
D
40
30
40
54
648
D
63
www.sigmaelektrik.com
10
MINIATURE
CIRCUIT BREAKERS
MCB
Protection Of The Lighting Circuits
When choosing the MBCs for protection of lighting circuits, it should be considered the power of the lamp, kind of the lamp, number of lamps and high
peak currents when the lamps are energized.
In the lighting circuits consisted of Sodium and Mercury vapor discharge lamps,the peak currents may occur up to 25 times of the rated current at the first
3 ms. Following this, 7 times of the rated current may be drawn within 2 seconds.
In the lighting circuits,inwhich there is electronic ballast worked with high frequency ,the peak currents may occur up to 25 times of the rated current at
the first 250 - 300 μs.
For these reasons, the MCBs are to be selected according to the type of lamps and their endurance against peak currents, so generally C type MCBs are
used in the lighting circuits.
But because of the cable resistance between the lamp and MCB, The value of peak current is limited to an inferior value depending on the distance.
The Current Of Fluorescent Lamp
Standard
Type
Fluorescent
Lamp
Single-Tube
Double Tube
The Current Of Compact Type Fluerescent Lamp
The current for 230 V (A)
Lamp Power
(W)
Magnetic Ballast
Compact
Type
Fluorescent
Lamp
Electronic Ballast
Not
Compensated
Compensated
Lamp Power
(W)
Lamp Current
(A)
10
0.08
18
0.11
26
0.15
18
0.20
0.14
0.10
36
0.33
0.23
0.18
58
0.5
0.36
0.28
2x18
0.28
0.18
8
0.075
2x36
0.46
0.35
11
0.095
2x58
0.72
0.52
16
0.125
21
0.17
Separate
Ballast Lamp
Lamp With
Ballast
The Current Of Sodium Vapor Lamp
The Current For 230 V (A)
Lamp Type
(W)
Power Demand
(W)
Rated Current (A)
Not Compensated
Starting
Compensated
xln (A)
Period
(min.)
High Pressure Sodium Vapor Lamps
50
60
0.76
0.3
1.4-1.6
between 4 and 6
70
80
1
0.45
1.4-1.6
between 4 and 6
100
115
1.2
0.65
1.4-1.6
between 4 and 6
150
168
1.8
0.85
1.4-1.6
between 4 and 6
250
274
3
1.4
1.4-1.6
between 4 and 6
400
431
4.4
2.2
1.4-1.6
between 4 and 6
1000
1055
10.45
4.9
1.4-1.6
between 4 and 6
Low Pressure Sodium Vapor Lamps
26
34.5
0.17
1.1-1.3
between 7 and 15
36
46.5
0.22
1.1-1.3
between 7 and 15
66
90.5
0.39
1.1-1.3
between 7 and 15
91
105.5
0.49
1.1-1.3
between 7 and 15
131
154
0.69
1.1-1.3
between 7 and 15
www.sigmaelektrik.com
11
MINIATURE
CIRCUIT BREAKERS
MCB
Maximum Number Of Fluorescent Lamps That Can Be Protected According To MCB’s Ampere
TC-L 24 W
TC-D + T26 W
TL + TC-L 36 W
TL 58 W
TC9/11 W
TC-D 13/18 W
TC 18 W
TC-L 18/24 W
TC-D + -T 26 W
TL-TC-L 36 W
TL 58 W
62
47
27
30
23
14
10
99
99
44
44
27
16
100
75
43
48
37
23
16
159
159
71
71
44
20
125
94
53
60
46
28
20
201
201
89
89
56
25
156
115
66
75
57
36
25
250
250
110
110
71
Rated Current
Of MCB (A)
TL + TC-L 18W
10
Rated Current
Of MCB (A)
TC-D 13 W
Compensated
TC 9/11 W
TC-D 13 W
Not Compensated
Maximum Number Of Sodium Vapor Lamps That Can Be Protected
According To MCB’s Ampere
www.sigmaelektrik.com
12
Max. Number Of Lamp
Rated Current Of
MCB (A)
Magnetic Tripping
Curve
150 W
200 W
6
D
2
1
10
D
3
2
400 W
1
16
D
5
3
1
20
D
6
4
2
25
D
8
5
2
32
D
10
7
3
40
D
13
8
4
50
D
16
11
5
63
D
21
14
7
MINIATURE
CIRCUIT BREAKERS
MCB
MCB Accessories
It is possible to make tripping and signalling remotely to the Sigma 6 kA and 10 kA MCBs by adding shunt trip and fault signal contact.
Fault signal contact are mounted to the left side of the surface of the MCBs or Shunt
Trip and when the MCBs are tripped because of the overload or short circuit, the
contacts change the position however when the MCBs open or close the circuit by
manually, the contacts do not change the position.
Type Code
Properties
Order code
SMAB
110 - 415 V AC / 110-220 V DC Shunt Trip Release
SMAB220
SMYK
1N0 + 1NC Signal Contact (lth: 4A, 250 V AC)
SMYK011
The MCB with shunt trip release and
fault signal contact
Fault Signal
Contact
MCB
Fault Signal Shunt Trip
Contact
Release
MCB
Scheme Of The Shunt Trip
Release
Scheme Of The Fault Signal Contact
Technical Specification Of Fault Signal Contact
Type
SMYK
Mounting
SND6000 and SND1000 type left side of MCB
Number Of Contacts
2 piece change-over
Rated Insulation Voltage
Ui
250
Rated Frequency
Hz
50/60
Rated Current
A
4
Min. Operating Voltage
V
5
Technical Specification Of Shunt Trip Release
Type
SMAB1
SMAB2
Mounting
Rated Operating Voltage
AC
12-110
110-415
Rated Operating Voltage
DC
12-60
110-220
Rated Frequency
Hz
50/60
50/60
SND6000 and SND1000 type left side of MCB
www.sigmaelektrik.com
13
MINIATURE
CIRCUIT BREAKERS
MCB
Dimensions Of MCB
3 kA
4.5 kA
6 kA
10 kA
Remote Control Shunt Trip Release
Fault Signal Contact
5.5
26
80
80
18
45
8,5
8.8
44
60
www.sigmaelektrik.com
14
MINIATURE
CIRCUIT BREAKERS
Order Information
SND3000
B And C Tripping Curve
EN 60898-1
3 kA MCB
Wiring Diagram
MCB
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
Order Code
B type
C Type
2
1
12
240
3SM102B
3SM102C
4
1
12
240
3SM104B
3SM104C
6
1
12
240
3SM106B
3SM106C
10
1
12
240
3SM110B
3SM110C
16
1
12
240
3SM116B
3SM116C
20
1
12
240
3SM120B
3SM120C
25
1
12
240
3SM125B
3SM125C
32
1
12
240
3SM132B
3SM132C
40
1
12
240
3SM140B
3SM140C
50
1
12
240
3SM150B
3SM150C
63
1
12
240
3SM163B
3SM163C
2
2
6
120
3SM202B
3SM202C
4
2
6
120
3SM204B
3SM204C
6
2
6
120
3SM206B
3SM206C
10
2
6
120
3SM210B
3SM210C
16
2
6
120
3SM216B
3SM216C
20
2
6
120
3SM220B
3SM220C
25
2
6
120
3SM225B
3SM225C
32
2
6
120
3SM232B
3SM232C
40
2
6
120
3SM240B
3SM240C
50
2
6
120
3SM250B
3SM250C
63
2
6
120
3SM263B
3SM263C
2
3
4
80
3SM302B
3SM302C
4
3
4
80
3SM304B
3SM304C
6
3
4
80
3SM306B
3SM306C
10
3
4
80
3SM310B
3SM310C
16
3
4
80
3SM316B
3SM316C
20
3
4
80
3SM320B
3SM320C
25
3
4
80
3SM325B
3SM325C
32
3
4
80
3SM332B
3SM332C
40
3
4
80
3SM340B
3SM340C
50
3
4
80
3SM350B
3SM350C
63
3
4
80
3SM363B
3SM363C
2
4
3
60
3SM402B
3SM402C
4
4
3
60
3SM404B
3SM404C
6
4
3
60
3SM406B
3SM406C
10
4
3
60
3SM410B
3SM410C
16
4
3
60
3SM416B
3SM416C
20
4
3
60
3SM420B
3SM420C
25
4
3
60
3SM425B
3SM425C
32
4
3
60
3SM432B
3SM432C
40
4
3
60
3SM440B
3SM440C
50
4
3
60
3SM450B
3SM450C
63
4
3
60
3SM463B
3SM463C
www.sigmaelektrik.com
15
MCB
MINIATURE
CIRCUIT BREAKERS
B And C Tripping Curve
EN 60898-1
4.5 kA MCB
SND4500
www.sigmaelektrik.com
16
Wiring Diagram
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
Order Code
B type
C Type
2
1
12
240
4SM102B
4SM102C
4
1
12
240
4SM104B
4SM104C
6
1
12
240
4SM106B
4SM106C
10
1
12
240
4SM110B
4SM110C
16
1
12
240
4SM116B
4SM116C
20
1
12
240
4SM120B
4SM120C
25
1
12
240
4SM125B
4SM125C
32
1
12
240
4SM132B
4SM132C
40
1
12
240
4SM140B
4SM140C
50
1
12
240
4SM150B
4SM150C
63
1
12
240
4SM163B
4SM163C
2
2
6
120
4SM202B
4SM202C
4
2
6
120
4SM204B
4SM204C
6
2
6
120
4SM206B
4SM206C
10
2
6
120
4SM210B
4SM210C
16
2
6
120
4SM216B
4SM216C
20
2
6
120
4SM220B
4SM220C
25
2
6
120
4SM225B
4SM225C
32
2
6
120
4SM232B
4SM232C
40
2
6
120
4SM240B
4SM240C
50
2
6
120
4SM250B
4SM250C
63
2
6
120
4SM263B
4SM263C
2
3
4
80
4SM302B
4SM302C
4
3
4
80
4SM304B
4SM304C
6
3
4
80
4SM306B
4SM306C
10
3
4
80
4SM310B
4SM310C
16
3
4
80
4SM316B
4SM316C
20
3
4
80
4SM320B
4SM320C
25
3
4
80
4SM325B
4SM325C
32
3
4
80
4SM332B
4SM332C
40
3
4
80
4SM340B
4SM340C
50
3
4
80
4SM350B
4SM350C
63
3
4
80
4SM363B
4SM363C
2
4
3
60
4SM402B
4SM402C
4
4
3
60
4SM404B
4SM404C
6
4
3
60
4SM406B
4SM406C
10
4
3
60
4SM410B
4SM410C
16
4
3
60
4SM416B
4SM416C
20
4
3
60
4SM420B
4SM420C
25
4
3
60
4SM425B
4SM425C
32
4
3
60
4SM432B
4SM432C
40
4
3
60
4SM440B
4SM440C
50
4
3
60
4SM450B
4SM450C
63
4
3
60
4SM463B
4SM463C
MINIATURE
CIRCUIT BREAKERS
MCB
B Tripping Curve
EN 60898-1
6 kA MCB
SND6000
Wiring Diagram
Rated Current
In (A)
Number Of Poles
Package (pcs.)
Box (pcs.)
Order Code
2
1
12
240
6SM102B
4
1
12
240
6SM104B
6
1
12
240
6SM106B
10
1
12
240
6SM110B
16
1
12
240
6SM116B
20
1
12
240
6SM120B
25
1
12
240
6SM125B
32
1
12
240
6SM132B
40
1
12
240
6SM140B
50
1
12
240
6SM150B
63
1
12
240
6SM163B
2
2
6
120
6SM202B
4
2
6
120
6SM204B
6
2
6
120
6SM206B
10
2
6
120
6SM210B
16
2
6
120
6SM216B
20
2
6
120
6SM220B
25
2
6
120
6SM225B
32
2
6
120
6SM232B
40
2
6
120
6SM240B
50
2
6
120
6SM250B
63
2
6
120
6SM263B
2
3
4
80
6SM302B
4
3
4
80
6SM304B
6
3
4
80
6SM306B
10
3
4
80
6SM310B
16
3
4
80
6SM316B
20
3
4
80
6SM320B
25
3
4
80
6SM325B
32
3
4
80
6SM332B
40
3
4
80
6SM340B
50
3
4
80
6SM350B
63
3
4
80
6SM363B
2
4
3
60
6SM402B
4
4
3
60
6SM404B
6
4
3
60
6SM406B
10
4
3
60
6SM410B
16
4
3
60
6SM416B
20
4
3
60
6SM420B
25
4
3
60
6SM425B
32
4
3
60
6SM432B
40
4
3
60
6SM440B
50
4
3
60
6SM450B
63
4
3
60
6SM463B
www.sigmaelektrik.com
17
MCB
MINIATURE
CIRCUIT BREAKERS
C And D Tripping Curve
EN 60898-1
6 kA MCB
SND6000
www.sigmaelektrik.com
18
Wiring Diagram
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
0.5
1
12
240
Order Code
C Type
D Type
6SM105C
1
1
12
240
6SM101C
2
1
12
240
6SM102C
6SM102D
4
1
12
240
6SM104C
6SM104D
6
1
12
240
6SM106C
6SM106D
10
1
12
240
6SM110C
6SM110D
16
1
12
240
6SM116C
6SM116D
20
1
12
240
6SM120C
6SM120D
25
1
12
240
6SM125C
6SM125D
32
1
12
240
6SM132C
6SM132D
40
1
12
240
6SM140C
6SM140D
50
1
12
240
6SM150C
6SM150D
63
1
12
240
6SM163C
6SM163D
80
1
8
120
6SM180C
6SM180D
100
1
8
120
6SM100C
6SM100D
125
1
8
120
6SM112C
6SM112D
2
2
6
120
6SM202C
6SM202D
4
2
6
120
6SM204C
6SM204D
6
2
6
120
6SM206C
6SM206D
10
2
6
120
6SM210C
6SM210D
16
2
6
120
6SM216C
6SM216D
20
2
6
120
6SM220C
6SM220D
25
2
6
120
6SM225C
6SM225D
32
2
6
120
6SM232C
6SM232D
40
2
6
120
6SM240C
6SM240D
50
2
6
120
6SM250C
6SM250D
63
2
3
60
6SM263C
6SM263D
80
2
4
60
6SM280C
6SM280D
100
2
4
60
6SM200C
6SM200D
125
2
4
60
6SM212C
6SM212D
MINIATURE
CIRCUIT BREAKERS
C And D Tripping Curve
EN 60898-1
6 kA MCB
SND6000
MCB
Wiring Diagram
Order Code
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
C Type
D Type
2
3
4
80
6SM302C
6SM302D
4
3
4
80
6SM304C
6SM304D
6
3
4
80
6SM306C
6SM306D
10
3
4
80
6SM310C
6SM310D
16
3
4
80
6SM316C
6SM316D
20
3
4
80
6SM320C
6SM320D
25
3
4
80
6SM325C
6SM325D
32
3
4
80
6SM332C
6SM332D
40
3
4
80
6SM340C
6SM340D
50
3
4
80
6SM350C
6SM350D
63
3
4
80
6SM363C
6SM363D
80
3
2
40
6SM380C
6SM380D
100
3
2
40
6SM300C
6SM300D
125
3
2
40
6SM312C
6SM312D
2
4
3
60
6SM402C
6SM402D
4
4
3
60
6SM404C
6SM404D
6
4
3
60
6SM406C
6SM406D
10
4
3
60
6SM410C
6SM410D
16
4
3
60
6SM416C
6SM416D
20
4
3
60
6SM420C
6SM420D
25
4
3
60
6SM425C
6SM425D
32
4
3
60
6SM432C
6SM432D
40
4
3
60
6SM440C
6SM440D
50
4
3
60
6SM450C
6SM450D
63
4
3
60
6SM463C
6SM463D
80
4
2
20
6SM480C
6SM480D
100
4
2
20
6SM400C
6SM400D
125
4
2
20
6SM412C
6SM412D
www.sigmaelektrik.com
19
MCB
MINIATURE
CIRCUIT BREAKERS
B Tripping Curve
EN 60898-1
10 kA MCB
SND10000
www.sigmaelektrik.com
20
Wiring Diagram
Rated Current
In (A)
Number Of Poles
Package (pcs.)
Box (pcs.)
Order Code
(B Type)
2
1
12
240
1SM102B
4
1
12
240
1SM104B
6
1
12
240
1SM106B
10
1
12
240
1SM110B
16
1
12
240
1SM116B
20
1
12
240
1SM120B
25
1
12
240
1SM125B
32
1
12
240
1SM132B
40
1
12
240
1SM140B
50
1
12
240
1SM150B
63
1
12
240
1SM163B
2
2
6
120
1SM202B
4
2
6
120
1SM204B
6
2
6
120
1SM206B
10
2
6
120
1SM210B
16
2
6
120
1SM216B
20
2
6
120
1SM220B
25
2
6
120
1SM225B
32
2
6
120
1SM232B
40
2
6
120
1SM240B
50
2
6
120
1SM250B
63
2
6
120
1SM263B
2
3
4
80
1SM302B
4
3
4
80
1SM304B
6
3
4
80
1SM306B
10
3
4
80
1SM310B
16
3
4
80
1SM316B
20
3
4
80
1SM320B
25
3
4
80
1SM325B
32
3
4
80
1SM332B
40
3
4
80
1SM340B
50
3
4
80
1SM350B
63
3
4
80
1SM363B
2
4
3
60
1SM402B
4
4
3
60
1SM404B
6
4
3
60
1SM406B
10
4
3
60
1SM410B
16
4
3
60
1SM416B
20
4
3
60
1SM420B
25
4
3
60
1SM425B
32
4
3
60
1SM432B
40
4
3
60
1SM440B
50
4
3
60
1SM450B
63
4
3
60
1SM463B
MINIATURE
CIRCUIT BREAKERS
C And D Tripping Curve
EN 60898-1
10 kA MCB
SND10000
MCB
Wiring Diagram
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
Order Code
C Type
D Type
0.5
1
12
240
1SM105C
1SM105D
1
1
12
240
1SM101C
1SM101D
2
1
12
240
1SM102C
1SM102D
4
1
12
240
1SM104C
1SM104D
6
1
12
240
1SM106C
1SM106D
10
1
12
240
1SM110C
1SM110D
16
1
12
240
1SM116C
1SM116D
20
1
12
240
1SM120C
1SM120D
25
1
12
240
1SM125C
1SM125D
32
1
12
240
1SM132C
1SM132D
40
1
12
240
1SM140C
1SM140D
50
1
12
240
1SM150C
1SM150D
63
1
12
240
1SM163C
1SM163D
80
1
8
120
1SM180C
1SM180D
100
1
8
120
1SM100C
1SM100D
125
1
8
120
1SM112C
1SM112D
2
2
6
120
1SM202C
1SM202D
4
2
6
120
1SM204C
1SM204D
6
2
6
120
1SM206C
1SM206D
10
2
6
120
1SM210C
1SM210D
16
2
6
120
1SM216C
1SM216D
20
2
6
120
1SM220C
1SM220D
25
2
6
120
1SM225C
1SM225D
32
2
6
120
1SM232C
1SM232D
40
2
6
120
1SM240C
1SM240D
50
2
6
120
1SM250C
1SM250D
63
2
3
60
1SM263C
1SM263D
80
2
4
60
1SM280C
1SM280D
100
2
4
60
1SM200C
1SM200D
125
2
4
60
1SM212C
1SM212D
www.sigmaelektrik.com
21
MCB
MINIATURE
CIRCUIT BREAKERS
C And D Tripping Curve
EN 60898-1
10 kA MCB
SND10000
Wiring Diagram
Rated Current
In (A)
Number Of
Poles
Package (pcs.)
Box (pcs.)
2
3
4
4
3
6
Order Code
C Type
D Type
80
1SM302C
1SM302D
4
80
1SM304C
1SM304D
3
4
80
1SM306C
1SM306D
10
3
4
80
1SM310C
1SM310D
16
3
4
80
1SM316C
1SM316D
20
3
4
80
1SM320C
1SM320D
25
3
4
80
1SM325C
1SM325D
32
3
4
80
1SM332C
1SM332D
40
3
4
80
1SM340C
1SM340D
50
3
4
80
1SM350C
1SM350D
63
3
4
80
1SM363C
1SM363D
80
3
2
40
1SM380C
1SM380D
100
3
2
40
1SM300C
1SM300D
125
3
2
40
1SM312C
1SM312D
2
4
3
60
1SM402C
1SM402D
4
4
3
60
1SM404C
1SM404D
6
4
3
60
1SM406C
1SM406D
10
4
3
60
1SM410C
1SM410D
16
4
3
60
1SM416C
1SM416D
20
4
3
60
1SM420C
1SM420D
25
4
3
60
1SM425C
1SM425D
32
4
3
60
1SM432C
1SM432D
40
4
3
60
1SM440C
1SM440D
50
4
3
60
1SM450C
1SM450D
63
4
3
60
1SM463C
1SM463D
80
4
2
20
1SM480C
1SM480D
100
4
2
20
1SM400C
1SM400D
125
4
2
20
1SM412C
1SM412D
C Tripping Curve
EN 60898-1
16 kA MCB
SND16000
www.sigmaelektrik.com
22
Wiring Diagram
Rated Current In (A)
Number Of Poles
Package (pcs.)
Box (pcs.)
Order Code
40
1
1
6
5SM140C
50
1
1
6
5SM150C
63
1
1
6
5SM163C
80
1
1
6
5SM180C
100
1
1
6
5SM100C
125
1
1
6
5SM125C
Download