MINIATURE CIRCUIT BREAKERS MCB C M B Contents www.sigmaelektrik.com 4 General Information.............................................................. 1 3 kA Miniature Circuit Breakers.............................................. 2 4.5 kA Miniature Circuit Breakers........................................... 3 6 kA Miniature Circuit Breakers.............................................. 4 10 kA Miniature Circuit Breakers............................................ 5 16 kA Miniature Circuit Breakers ........................................... 6 Installation............................................................................. 7 Normal Service Conditions .................................................. 7 Tripping Charactectics And Selection .................................. 8 Protection Of The DC Circuits................................................ 9 Influence Of Non-Standard Fruquencies............................... 9 Power Loss............................................................................. 9 Protection Of Motors............................................................. 10 Protection Of The Lighting Circuits......................................... 11 MCB Accessories................................................................... 13 Dimensions Of MCB............................................................... 14 Order Information.................................................................. 15 MINIATURE CIRCUIT BREAKERS MCB General Information Sigma MCBs are such devices that protect their connected circuits against short circuit and overload. Sigma MCBs produced as 3 kA, 4.5 kA, 6 kA, 10 kA and 16kA according to the EN 60898-1, EN 60947-2 and VDE 0660. They are also conforming to the Low Voltage Directive (LVD) 73/23/EEC. 1 2 3 4 5 3 kA MCB 4.5 kA MCB 6 kA MCB 10 kA MCB 6 7 7 8 9 9 9 10 11 13 14 15 Handle Tripping mechanism Magnetic coil Connection terminals Fixed contact Bi-metal Arc Extinguisher The main components that make up a miniature circuit breaker www.sigmaelektrik.com 1 MINIATURE CIRCUIT BREAKERS MCB 3 kA Miniature Circuit Breakers Technical Specifications Type SND 3000 No Of Poles 1 Rated Current (at 30 °C) 2 3 4 A 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 AC (V) 240/415 Rated Voltage Ue Rated Insulation Voltage AC (V) Rated Impulse Voltage Uimp kV 6 Rated Breaking Capacity Icn kA 3 690 Selectivity Class 3 Electrical Life ope. Mechanical Life ope. 230 V 6.000 20.000 Protection Class IP 20 Ambient Operating Temperature o C between -5 and +40 Storage Temperature o C between -40 and +55 Colour RAL 7035 Assembly (EN 60715) 35 mm DIN Rail Connection Capacity (min - max) mm2 1-25 Max. Tightenning Torque Nm 2 Tripping Characteristics 10.000 5.000 1h 2.000 1.000 500 10.000 5.000 1h 2.000 1.000 500 200 200 100 50 100 50 20 10 5 20 10 5 t(s) t(s) 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.2 0.1 0.05 0.02 0.01 0.005 0.005 0.002 0.001 0.5 0.002 0.001 0.5 1 2 3 4 5 7 10 XIn B Curve www.sigmaelektrik.com 2 2 1 0.5 20 30 50 70 100 200 1 2 3 4 5 7 10 XIn C Curve 20 30 50 70 100 200 MINIATURE CIRCUIT BREAKERS MCB 4.5 kA Miniature Circuit Breaker Technical Specifications Type SND 4500 No Of Poles 1 Rated Current (at 30 °C) 2 3 4 A 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 Rated Voltage Ue AC (V) 240/415 Rated Insulation Voltage Ui V 690 Rated Impulse Voltage Uimp kV 6 Rated Breaking Capacity Icn kA 4.5 Selectivity Class 3 Electrical Life ope. Mechanical Life ope. 230 V 6.000 20.000 Protection Class IP 20 Ambient Operating Temperature o C between -5 and +40 Storage Temperature o C between -40 and +55 Colour RAL 7035 Assembly (EN 60715) 35 mm DIN Rail Connection Capacity (min - max) mm2 1-25 Max. Tightenning Torque Nm 2 Tripping Characteristics t(s) 10.000 5.000 1h 2.000 1.000 500 10.000 5.000 1h 2.000 1.000 500 200 200 100 50 100 50 20 10 5 20 10 5 t(s) 2 1 0.5 2 1 0.5 0.2 0.1 0.05 0.02 0.01 0.2 0.1 0.05 0.02 0.01 0.005 0.005 0.002 0.001 0.5 0.002 0.001 0.5 1 2 3 4 5 7 10 XIn B Curve 20 30 50 70 100 200 1 2 3 4 5 7 10 XIn 20 30 50 70 100 200 C Curve www.sigmaelektrik.com 3 MINIATURE CIRCUIT BREAKERS MCB 6 kA Miniature Circuit Breaker Technical Specifications Type SND 6000 No Of Poles 1 Rated Current (at 30 °C) 2 3 4 1 2 3 A 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 80, 100, 125 415 415 Rated Voltage Ue AC (V) Rated Insulation Voltage Ui V 690 Rated Impulse Voltage Uimp kV 6 Rated Breaking Capacity Icn kA 6 Selectivity Class 4 3 Electrical Life ope. Mechanical Life ope. 230 V 6.000 2.000 20.000 10.000 Protection Class IP 20 Ambient Operating Temperature o C between -5 and +40 Storage Temperature o C between -40 and +55 Colour RAL 7035 Assembly (EN 60715) 35 mm DIN Rail Connection Capacity (min - max) mm2 1-25 1-50 Max. Tightenning Torque Nm 2 3.5 Tripping Characteristics 10000 6000 4000 3600 2000 1000 600 400 10000 6000 4000 3600 2000 1000 600 400 10000 6000 4000 3600 2000 1000 600 400 200 100 60 40 200 100 60 40 200 100 60 40 20 10 6 4 20 10 6 4 20 10 6 4 t(s) t(s) 2 1 0,6 0,4 0,2 t(s) 2 1 0,6 0,4 0,2 2 1 0,6 0,4 0,2 0,1 0,1 0,1 0,04 0,02 0,04 0,02 0,04 0,02 0,01 0,004 1 1,5 2 1,13 1,45 3 www.sigmaelektrik.com 4 4 6 8 10 xln B Curve 15 20 30 40 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 xln C Curve 15 20 30 40 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 xln D Curve 15 20 30 40 MINIATURE CIRCUIT BREAKERS MCB 10 kA Miniature Circuit Breaker Technical Specifications Type SND 10000 No Of Poles 1 Rated Current (at 30 °C) 2 3 4 1 2 3 A 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 80, 100, 125 415 415 Rated Voltage Ue AC (V) Rated Insulation Voltage Ui V 690 Rated Impulse Voltage Uimp kV 6 Rated Breaking Capacity Icn kA 10 Selectivity Class 4 3 Electrical Life ope. Mechanical Life ope. 230 V 6.000 2.000 20.000 10.000 Protection Class IP 20 Ambient Operating Temperature o C between -5 and +40 Storage Temperature o C between -40 and +55 Colour RAL 7035 Assembly (EN 60715) 35 mm DIN Rail Connection Capacity (min - max) mm2 1-25 1-50 Max. Tightenning Torque Nm 2 3.5 Tripping Characteristics 10000 6000 4000 3600 2000 1000 600 400 10000 6000 4000 3600 2000 1000 600 400 10000 6000 4000 3600 2000 1000 600 400 200 100 60 40 200 100 60 40 200 100 60 40 20 10 6 4 20 10 6 4 20 10 6 4 t(s) t(s) 2 1 0,6 0,4 0,2 t(s) 2 1 0,6 0,4 0,2 2 1 0,6 0,4 0,2 0,1 0,1 0,1 0,04 0,02 0,04 0,02 0,04 0,02 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 xln B Curve 15 20 30 40 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 xln C Curve 15 20 30 40 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 15 20 30 40 xln D Curve www.sigmaelektrik.com 5 MINIATURE CIRCUIT BREAKERS MCB 16 kA Miniature Circuit Breaker Technical Specifications Type SND 16000 No Of Poles 1 Rated Current (at 30 °C) Rated Voltage Ue Rated Voltage A 40, 50, 63, 80, 100, 125 AC (V) 415 DC (V) 60 Rated Insulation Voltage Ui V 690 Rated Impulse Voltage Uimp kV 6 Rated Breaking Capacity Ics kA 16 Selectivity Class 3 Electrical Life ope. Mechanical Life ope. 230 V 2.000 10.000 Protection Class IP 20 Ambient Operating Temperature o C between -5 and +40 Storage Temperature o C between -40 and +55 Colour RAL 7035 Assembly (EN 60715) 35 mm DIN Rail Connection Capacity (min - max) mm2 2.5 - 50 Tightenning Torque Nm 3 Tripping Characteristics 10000 6000 4000 3600 2000 1000 600 400 10000 6000 4000 3600 2000 1000 600 400 200 100 60 40 200 100 60 40 20 10 6 4 20 10 6 4 t(s) t(s) 2 1 0,6 0,4 0,2 2 1 0,6 0,4 0,2 0,1 0,1 0,04 0,02 0,04 0,02 0,01 0,004 1 1,5 2 1,13 1,45 3 www.sigmaelektrik.com 6 4 6 8 10 xln C Curve 15 20 30 40 0,01 0,004 1 1,5 2 1,13 1,45 3 4 6 8 10 xln D Curve 15 20 30 40 MINIATURE CIRCUIT BREAKERS MCB Installation Up to 25 mm2 cable can be connected to the sigma MCBs, which are designed to be easily mounted on to the 35 mm DIN rail according to EN 50022. Besides, connection with collective MCB Bus bar is possible. Maximum torque applied for connection screws is 2 Nm. Higher torque may damage to the screws or terminal connections. Although Sigma MCBs have availability to make energy entrance from both upper side and under side, it is recommended to make from upper side. Connection Terminals own IP20 protection degree according to the EN60529. The Design that has IP20 protection degree properties for safe to touch. Sealable properties DIN Rail Specifications should be suitable according to EN50022. Normal Service Conditions Sigma MCBs are designed to operate at ambient temperatures between -5 oC and +40 oC. The calibration temperature is 30 oC. If ambient temperature value is different than 30 oC, please use below table to compansate tripping time. The upper limit for relative humidity is 50% at a maximum temperature of +40 oC, although the breakers can operate at higher relative humidities for lower temperatures (e.g.: a relative humidity of the 90% at +20 oC ambient temperature would be acceptable). Sigma MCB specification throughout this catalogue are for installations where the altitude does not exceed 2000m above sea level. For installations above at higher altitudues, it is necessary to take into account the reduction of the dielectric strength and of the cooling effect of the air. The ambient temperature during transport and storage must not exceed the interval between -40 oC and +55 oC. For short periods not exceeding 24 hour up to +70 oC can be reached with a relative humidity of 30%. During this period it is important to avoid water condensation in side the breakers, otherwise, oxidation and stain spots might appear affecting thus the normal operation of the breaker. Influence Of Ambient Temperature On Nominal Currents In [A] / C -10 0 10 20 30 35 40 45 50 55 60 2 2.3 2.2 2.2 2.1 2 2 1.9 1.9 1.9 1.8 1.8 4 4.7 4.5 4.3 4.2 4 3.9 3.9 3.8 3.7 3.6 3.5 6 7 6.7 6.5 6.3 6 5.9 5.8 5.7 5.6 5.4 5.3 10 12 11 11 10 10 9.9 9.7 9.5 9.4 9 8.9 16 19 18 17 17 16 16 15 15 15 14 14 20 23 22 22 21 20 20 19 19 19 18 18 25 29 28 27 26 25 25 24 24 23 23 22 32 37 36 35 33 32 32 31 30 30 29 28 40 47 45 43 42 40 39 39 38 37 36 35 50 58 56 54 52 50 49 48 47 46 45 44 63 73 71 68 66 63 62 61 60 58 57 56 O www.sigmaelektrik.com 7 MINIATURE CIRCUIT BREAKERS MCB minute minute Second Second minute Second Tripping Characteristics And Selection Application Selection For MCB Tripping Characteristics I 1 I 2 I 3 I 4 Thermal Non Tripping Current Type B characteristics are suitable for moderately inductive loads having that have little or no switching surges i.e. electric heating, water heating, ovens etc. Thermal Tripping Current Type C characteristics MCBs can be used in general applications such as lighting, ring/radial socket outlets and small motors. Magnetic Non-tripping Installations where the equipment is likely to produce abnormally high inrush currents, such as transformers, welding machines or induction motors are suited to type D characteristic. Magnetic Tripping Current Magnetic Tripping Characteristic Rated Current (In) Test Current Tripping Time Result Rated Current (In) Test Current Tripping Time Result B All 3 In t ≥ 0.1 sec. not tripped In ≤ 63 A 1.13 In t ≥ 1 hour not tripped B All 5 In t < 0.1 sec. tripped In > 63 A 1.13 In t ≥ 2 hour not tripped C All 5 In t ≥ 0.1 sec. not tripped In ≤ 63 A 1.45 In t < 1 hour tripped C All 10 In t < 0.1 sec. tripped In > 63 A 1.45 In t < 2 hour tripped D All 10 In t ≥ 0.1 sec. not tripped In ≤ 32 A 2.55 In 1 sec. < t < 60 sec. tripped D All 20 In t < 0.1 sec. tripped In > 32 A 2.55 In 1 sec. < t < 120 sec. tripped Magnetic Tripping Conditions www.sigmaelektrik.com 8 Thermal Tripping Conditions MINIATURE CIRCUIT BREAKERS MCB Protection Of The DC Circuits The thermal characteristics for Sigma MCBs are unaffected by the type of current applied, that is either direct current or alternating current. The magnetic trip value increases by 40%. For example, in the case of a breaker of tripping characteristics B and 10A rated current, its magnetic tripping value will be between 30A and 50A in alternating current. The magnetic tripping value for the same breaker in direct current will be between 42.4A and 70.7A For DC service, the MCBs full rated breaking capacity can be achieved without any reduction in performance by connecting protected poles in series. For values up to 48V=1 protected pole can be used unpaired of the breaking capacity value. Between 48 and 110V=2 protected poles series connected can be used without reduction in the breaking capacity. Between 110 and 150V=, 3 protected poles series connected must be used, and 4 poles up to 200V= Magnetic Tripping Curve Magnetic Tripping Value For AC Circuits Magnetic Thermal Tripping Value Tripping Value For DC Circuits For AC Circuits B 3-5 4-7 > 1.45xIn C 5 - 10 7 - 14 D 10 - 20 14 - 28 Magnetic Tripping Value For DC circuits Short-Circuit Breaking Capacity (kA) Instantaneous Tripping 1P 2P 3P 4P > 1.45xIn ≤ 48 V 6 6 10 10 > 1.45xIn > 1.45xIn 110 V 6 6 10 > 1.45xIn > 1.45xIn 220 V 10 Influence Of Non-Standard Frequencies For operational frequencies greater than 50/60Hz, the effect of these non-standard frequencies must be taken into consideration. Thermal characteristics are independent from variation in frequency. Magnetic tripping values are directly affected by frequency. As a reference, for frequencies of 100, 200, 300 and 400Hz, the values at which the magnetic tripping occurs become increased in a 10, 20, 30 and 40% respectively. Frequency Hz. Magnetic Tripping Value B C D 17 - 60 3-5 5 - 10 10 - 20 100 3.3 - 5.5 5.5 - 11 11 - 22 Frequency Hz. Magnetic Tripping Value B C D 200 3.6 - 6 6 - 12 12 - 24 400 4.5 - 7 7.5 - 15 15 - 30 Power Loss Sigma MCBs have been designed to lose minimum power in their connected circuits and their power loss per pole is much less than the value stated in EN 60898-1 standards. Rated Current In (A) Measured Maximum Power Loss Per Pole At The Sigma MCB (W) Should Be The Maximum Power Loss According To The EN 60898-1 Rated Current In (A) Measured Maximum Power Loss Per Pole At The Sigma MCB (W) Should Be The Maximum Power Loss According To The EN 60898-1 2 0.74 3 25 2.3 4.5 6 1 3 32 4 6 10 2.1 3 40 4.9 7.5 16 2.5 3.5 50 5.11 9 20 3 4.5 63 5.8 13 www.sigmaelektrik.com 9 MINIATURE CIRCUIT BREAKERS MCB Protection Of Motors The protection of motors against the effects of an internal short circuit must be ensured, allowing at the same time the presence of short duration overcurrents (starting) without causing tripping of the protection element. This element must also ensure protection of the line, of the contactor and of the thermal relay associated to the motor. 220-240 V Single Phase Induction Motor Rated Power Miniature Circuit Breaker Rated Current (A) Starting Current (A) Tripping Curve Rated Current(A) 0.25 1.5 18 C or D 6 0.5 3 36 C or D 6 0.55 0.75 4.5 54 D 6 0.75 1 5.5 66 C or D 10 kW Hp 0.18 0.37 1.1 1.5 8.5 102 D 10 1.5 2 10.5 126 C or D 16 2.2 3 15.5 186 D 20 3 4 20 240 D 32 3.75 5 24 288 D 32 5.5 7.5 34 408 D 40 7.5 10 45 540 D 63 400-415 V Three-Phase Induction Motor Rated Power Starting Current (A) Tripping Curve Rated Current(A) 0.7 8.4 C 6 1.35 16.2 C 6 1.55 18.6 C 6 1 1.93 23.2 C 6 1.5 2.5 30 C 6 3.5 42 C or D 6 kW Hp 0.18 0.25 0.37 0.5 0.55 0.75 0.75 1.1 1.5 2 Rated Current (A) Miniature Circuit Breaker 2.2 3 4.8 57.6 D 6 3 4 6.4 76.8 D 10 3.75 5 7.8 93.6 D 10 5.5 7.5 11 132 D 16 7.5 10 14.4 172.8 D 16 9.33 12.5 17.3 207.6 D 20 11 15 21 252 D 25 15 20 28 336 D 32 18.5 25 35 420 D 40 22 30 40 480 D 40 30 40 54 648 D 63 www.sigmaelektrik.com 10 MINIATURE CIRCUIT BREAKERS MCB Protection Of The Lighting Circuits When choosing the MBCs for protection of lighting circuits, it should be considered the power of the lamp, kind of the lamp, number of lamps and high peak currents when the lamps are energized. In the lighting circuits consisted of Sodium and Mercury vapor discharge lamps,the peak currents may occur up to 25 times of the rated current at the first 3 ms. Following this, 7 times of the rated current may be drawn within 2 seconds. In the lighting circuits,inwhich there is electronic ballast worked with high frequency ,the peak currents may occur up to 25 times of the rated current at the first 250 - 300 μs. For these reasons, the MCBs are to be selected according to the type of lamps and their endurance against peak currents, so generally C type MCBs are used in the lighting circuits. But because of the cable resistance between the lamp and MCB, The value of peak current is limited to an inferior value depending on the distance. The Current Of Fluorescent Lamp Standard Type Fluorescent Lamp Single-Tube Double Tube The Current Of Compact Type Fluerescent Lamp The current for 230 V (A) Lamp Power (W) Magnetic Ballast Compact Type Fluorescent Lamp Electronic Ballast Not Compensated Compensated Lamp Power (W) Lamp Current (A) 10 0.08 18 0.11 26 0.15 18 0.20 0.14 0.10 36 0.33 0.23 0.18 58 0.5 0.36 0.28 2x18 0.28 0.18 8 0.075 2x36 0.46 0.35 11 0.095 2x58 0.72 0.52 16 0.125 21 0.17 Separate Ballast Lamp Lamp With Ballast The Current Of Sodium Vapor Lamp The Current For 230 V (A) Lamp Type (W) Power Demand (W) Rated Current (A) Not Compensated Starting Compensated xln (A) Period (min.) High Pressure Sodium Vapor Lamps 50 60 0.76 0.3 1.4-1.6 between 4 and 6 70 80 1 0.45 1.4-1.6 between 4 and 6 100 115 1.2 0.65 1.4-1.6 between 4 and 6 150 168 1.8 0.85 1.4-1.6 between 4 and 6 250 274 3 1.4 1.4-1.6 between 4 and 6 400 431 4.4 2.2 1.4-1.6 between 4 and 6 1000 1055 10.45 4.9 1.4-1.6 between 4 and 6 Low Pressure Sodium Vapor Lamps 26 34.5 0.17 1.1-1.3 between 7 and 15 36 46.5 0.22 1.1-1.3 between 7 and 15 66 90.5 0.39 1.1-1.3 between 7 and 15 91 105.5 0.49 1.1-1.3 between 7 and 15 131 154 0.69 1.1-1.3 between 7 and 15 www.sigmaelektrik.com 11 MINIATURE CIRCUIT BREAKERS MCB Maximum Number Of Fluorescent Lamps That Can Be Protected According To MCB’s Ampere TC-L 24 W TC-D + T26 W TL + TC-L 36 W TL 58 W TC9/11 W TC-D 13/18 W TC 18 W TC-L 18/24 W TC-D + -T 26 W TL-TC-L 36 W TL 58 W 62 47 27 30 23 14 10 99 99 44 44 27 16 100 75 43 48 37 23 16 159 159 71 71 44 20 125 94 53 60 46 28 20 201 201 89 89 56 25 156 115 66 75 57 36 25 250 250 110 110 71 Rated Current Of MCB (A) TL + TC-L 18W 10 Rated Current Of MCB (A) TC-D 13 W Compensated TC 9/11 W TC-D 13 W Not Compensated Maximum Number Of Sodium Vapor Lamps That Can Be Protected According To MCB’s Ampere www.sigmaelektrik.com 12 Max. Number Of Lamp Rated Current Of MCB (A) Magnetic Tripping Curve 150 W 200 W 6 D 2 1 10 D 3 2 400 W 1 16 D 5 3 1 20 D 6 4 2 25 D 8 5 2 32 D 10 7 3 40 D 13 8 4 50 D 16 11 5 63 D 21 14 7 MINIATURE CIRCUIT BREAKERS MCB MCB Accessories It is possible to make tripping and signalling remotely to the Sigma 6 kA and 10 kA MCBs by adding shunt trip and fault signal contact. Fault signal contact are mounted to the left side of the surface of the MCBs or Shunt Trip and when the MCBs are tripped because of the overload or short circuit, the contacts change the position however when the MCBs open or close the circuit by manually, the contacts do not change the position. Type Code Properties Order code SMAB 110 - 415 V AC / 110-220 V DC Shunt Trip Release SMAB220 SMYK 1N0 + 1NC Signal Contact (lth: 4A, 250 V AC) SMYK011 The MCB with shunt trip release and fault signal contact Fault Signal Contact MCB Fault Signal Shunt Trip Contact Release MCB Scheme Of The Shunt Trip Release Scheme Of The Fault Signal Contact Technical Specification Of Fault Signal Contact Type SMYK Mounting SND6000 and SND1000 type left side of MCB Number Of Contacts 2 piece change-over Rated Insulation Voltage Ui 250 Rated Frequency Hz 50/60 Rated Current A 4 Min. Operating Voltage V 5 Technical Specification Of Shunt Trip Release Type SMAB1 SMAB2 Mounting Rated Operating Voltage AC 12-110 110-415 Rated Operating Voltage DC 12-60 110-220 Rated Frequency Hz 50/60 50/60 SND6000 and SND1000 type left side of MCB www.sigmaelektrik.com 13 MINIATURE CIRCUIT BREAKERS MCB Dimensions Of MCB 3 kA 4.5 kA 6 kA 10 kA Remote Control Shunt Trip Release Fault Signal Contact 5.5 26 80 80 18 45 8,5 8.8 44 60 www.sigmaelektrik.com 14 MINIATURE CIRCUIT BREAKERS Order Information SND3000 B And C Tripping Curve EN 60898-1 3 kA MCB Wiring Diagram MCB Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code B type C Type 2 1 12 240 3SM102B 3SM102C 4 1 12 240 3SM104B 3SM104C 6 1 12 240 3SM106B 3SM106C 10 1 12 240 3SM110B 3SM110C 16 1 12 240 3SM116B 3SM116C 20 1 12 240 3SM120B 3SM120C 25 1 12 240 3SM125B 3SM125C 32 1 12 240 3SM132B 3SM132C 40 1 12 240 3SM140B 3SM140C 50 1 12 240 3SM150B 3SM150C 63 1 12 240 3SM163B 3SM163C 2 2 6 120 3SM202B 3SM202C 4 2 6 120 3SM204B 3SM204C 6 2 6 120 3SM206B 3SM206C 10 2 6 120 3SM210B 3SM210C 16 2 6 120 3SM216B 3SM216C 20 2 6 120 3SM220B 3SM220C 25 2 6 120 3SM225B 3SM225C 32 2 6 120 3SM232B 3SM232C 40 2 6 120 3SM240B 3SM240C 50 2 6 120 3SM250B 3SM250C 63 2 6 120 3SM263B 3SM263C 2 3 4 80 3SM302B 3SM302C 4 3 4 80 3SM304B 3SM304C 6 3 4 80 3SM306B 3SM306C 10 3 4 80 3SM310B 3SM310C 16 3 4 80 3SM316B 3SM316C 20 3 4 80 3SM320B 3SM320C 25 3 4 80 3SM325B 3SM325C 32 3 4 80 3SM332B 3SM332C 40 3 4 80 3SM340B 3SM340C 50 3 4 80 3SM350B 3SM350C 63 3 4 80 3SM363B 3SM363C 2 4 3 60 3SM402B 3SM402C 4 4 3 60 3SM404B 3SM404C 6 4 3 60 3SM406B 3SM406C 10 4 3 60 3SM410B 3SM410C 16 4 3 60 3SM416B 3SM416C 20 4 3 60 3SM420B 3SM420C 25 4 3 60 3SM425B 3SM425C 32 4 3 60 3SM432B 3SM432C 40 4 3 60 3SM440B 3SM440C 50 4 3 60 3SM450B 3SM450C 63 4 3 60 3SM463B 3SM463C www.sigmaelektrik.com 15 MCB MINIATURE CIRCUIT BREAKERS B And C Tripping Curve EN 60898-1 4.5 kA MCB SND4500 www.sigmaelektrik.com 16 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code B type C Type 2 1 12 240 4SM102B 4SM102C 4 1 12 240 4SM104B 4SM104C 6 1 12 240 4SM106B 4SM106C 10 1 12 240 4SM110B 4SM110C 16 1 12 240 4SM116B 4SM116C 20 1 12 240 4SM120B 4SM120C 25 1 12 240 4SM125B 4SM125C 32 1 12 240 4SM132B 4SM132C 40 1 12 240 4SM140B 4SM140C 50 1 12 240 4SM150B 4SM150C 63 1 12 240 4SM163B 4SM163C 2 2 6 120 4SM202B 4SM202C 4 2 6 120 4SM204B 4SM204C 6 2 6 120 4SM206B 4SM206C 10 2 6 120 4SM210B 4SM210C 16 2 6 120 4SM216B 4SM216C 20 2 6 120 4SM220B 4SM220C 25 2 6 120 4SM225B 4SM225C 32 2 6 120 4SM232B 4SM232C 40 2 6 120 4SM240B 4SM240C 50 2 6 120 4SM250B 4SM250C 63 2 6 120 4SM263B 4SM263C 2 3 4 80 4SM302B 4SM302C 4 3 4 80 4SM304B 4SM304C 6 3 4 80 4SM306B 4SM306C 10 3 4 80 4SM310B 4SM310C 16 3 4 80 4SM316B 4SM316C 20 3 4 80 4SM320B 4SM320C 25 3 4 80 4SM325B 4SM325C 32 3 4 80 4SM332B 4SM332C 40 3 4 80 4SM340B 4SM340C 50 3 4 80 4SM350B 4SM350C 63 3 4 80 4SM363B 4SM363C 2 4 3 60 4SM402B 4SM402C 4 4 3 60 4SM404B 4SM404C 6 4 3 60 4SM406B 4SM406C 10 4 3 60 4SM410B 4SM410C 16 4 3 60 4SM416B 4SM416C 20 4 3 60 4SM420B 4SM420C 25 4 3 60 4SM425B 4SM425C 32 4 3 60 4SM432B 4SM432C 40 4 3 60 4SM440B 4SM440C 50 4 3 60 4SM450B 4SM450C 63 4 3 60 4SM463B 4SM463C MINIATURE CIRCUIT BREAKERS MCB B Tripping Curve EN 60898-1 6 kA MCB SND6000 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code 2 1 12 240 6SM102B 4 1 12 240 6SM104B 6 1 12 240 6SM106B 10 1 12 240 6SM110B 16 1 12 240 6SM116B 20 1 12 240 6SM120B 25 1 12 240 6SM125B 32 1 12 240 6SM132B 40 1 12 240 6SM140B 50 1 12 240 6SM150B 63 1 12 240 6SM163B 2 2 6 120 6SM202B 4 2 6 120 6SM204B 6 2 6 120 6SM206B 10 2 6 120 6SM210B 16 2 6 120 6SM216B 20 2 6 120 6SM220B 25 2 6 120 6SM225B 32 2 6 120 6SM232B 40 2 6 120 6SM240B 50 2 6 120 6SM250B 63 2 6 120 6SM263B 2 3 4 80 6SM302B 4 3 4 80 6SM304B 6 3 4 80 6SM306B 10 3 4 80 6SM310B 16 3 4 80 6SM316B 20 3 4 80 6SM320B 25 3 4 80 6SM325B 32 3 4 80 6SM332B 40 3 4 80 6SM340B 50 3 4 80 6SM350B 63 3 4 80 6SM363B 2 4 3 60 6SM402B 4 4 3 60 6SM404B 6 4 3 60 6SM406B 10 4 3 60 6SM410B 16 4 3 60 6SM416B 20 4 3 60 6SM420B 25 4 3 60 6SM425B 32 4 3 60 6SM432B 40 4 3 60 6SM440B 50 4 3 60 6SM450B 63 4 3 60 6SM463B www.sigmaelektrik.com 17 MCB MINIATURE CIRCUIT BREAKERS C And D Tripping Curve EN 60898-1 6 kA MCB SND6000 www.sigmaelektrik.com 18 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) 0.5 1 12 240 Order Code C Type D Type 6SM105C 1 1 12 240 6SM101C 2 1 12 240 6SM102C 6SM102D 4 1 12 240 6SM104C 6SM104D 6 1 12 240 6SM106C 6SM106D 10 1 12 240 6SM110C 6SM110D 16 1 12 240 6SM116C 6SM116D 20 1 12 240 6SM120C 6SM120D 25 1 12 240 6SM125C 6SM125D 32 1 12 240 6SM132C 6SM132D 40 1 12 240 6SM140C 6SM140D 50 1 12 240 6SM150C 6SM150D 63 1 12 240 6SM163C 6SM163D 80 1 8 120 6SM180C 6SM180D 100 1 8 120 6SM100C 6SM100D 125 1 8 120 6SM112C 6SM112D 2 2 6 120 6SM202C 6SM202D 4 2 6 120 6SM204C 6SM204D 6 2 6 120 6SM206C 6SM206D 10 2 6 120 6SM210C 6SM210D 16 2 6 120 6SM216C 6SM216D 20 2 6 120 6SM220C 6SM220D 25 2 6 120 6SM225C 6SM225D 32 2 6 120 6SM232C 6SM232D 40 2 6 120 6SM240C 6SM240D 50 2 6 120 6SM250C 6SM250D 63 2 3 60 6SM263C 6SM263D 80 2 4 60 6SM280C 6SM280D 100 2 4 60 6SM200C 6SM200D 125 2 4 60 6SM212C 6SM212D MINIATURE CIRCUIT BREAKERS C And D Tripping Curve EN 60898-1 6 kA MCB SND6000 MCB Wiring Diagram Order Code Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) C Type D Type 2 3 4 80 6SM302C 6SM302D 4 3 4 80 6SM304C 6SM304D 6 3 4 80 6SM306C 6SM306D 10 3 4 80 6SM310C 6SM310D 16 3 4 80 6SM316C 6SM316D 20 3 4 80 6SM320C 6SM320D 25 3 4 80 6SM325C 6SM325D 32 3 4 80 6SM332C 6SM332D 40 3 4 80 6SM340C 6SM340D 50 3 4 80 6SM350C 6SM350D 63 3 4 80 6SM363C 6SM363D 80 3 2 40 6SM380C 6SM380D 100 3 2 40 6SM300C 6SM300D 125 3 2 40 6SM312C 6SM312D 2 4 3 60 6SM402C 6SM402D 4 4 3 60 6SM404C 6SM404D 6 4 3 60 6SM406C 6SM406D 10 4 3 60 6SM410C 6SM410D 16 4 3 60 6SM416C 6SM416D 20 4 3 60 6SM420C 6SM420D 25 4 3 60 6SM425C 6SM425D 32 4 3 60 6SM432C 6SM432D 40 4 3 60 6SM440C 6SM440D 50 4 3 60 6SM450C 6SM450D 63 4 3 60 6SM463C 6SM463D 80 4 2 20 6SM480C 6SM480D 100 4 2 20 6SM400C 6SM400D 125 4 2 20 6SM412C 6SM412D www.sigmaelektrik.com 19 MCB MINIATURE CIRCUIT BREAKERS B Tripping Curve EN 60898-1 10 kA MCB SND10000 www.sigmaelektrik.com 20 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code (B Type) 2 1 12 240 1SM102B 4 1 12 240 1SM104B 6 1 12 240 1SM106B 10 1 12 240 1SM110B 16 1 12 240 1SM116B 20 1 12 240 1SM120B 25 1 12 240 1SM125B 32 1 12 240 1SM132B 40 1 12 240 1SM140B 50 1 12 240 1SM150B 63 1 12 240 1SM163B 2 2 6 120 1SM202B 4 2 6 120 1SM204B 6 2 6 120 1SM206B 10 2 6 120 1SM210B 16 2 6 120 1SM216B 20 2 6 120 1SM220B 25 2 6 120 1SM225B 32 2 6 120 1SM232B 40 2 6 120 1SM240B 50 2 6 120 1SM250B 63 2 6 120 1SM263B 2 3 4 80 1SM302B 4 3 4 80 1SM304B 6 3 4 80 1SM306B 10 3 4 80 1SM310B 16 3 4 80 1SM316B 20 3 4 80 1SM320B 25 3 4 80 1SM325B 32 3 4 80 1SM332B 40 3 4 80 1SM340B 50 3 4 80 1SM350B 63 3 4 80 1SM363B 2 4 3 60 1SM402B 4 4 3 60 1SM404B 6 4 3 60 1SM406B 10 4 3 60 1SM410B 16 4 3 60 1SM416B 20 4 3 60 1SM420B 25 4 3 60 1SM425B 32 4 3 60 1SM432B 40 4 3 60 1SM440B 50 4 3 60 1SM450B 63 4 3 60 1SM463B MINIATURE CIRCUIT BREAKERS C And D Tripping Curve EN 60898-1 10 kA MCB SND10000 MCB Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code C Type D Type 0.5 1 12 240 1SM105C 1SM105D 1 1 12 240 1SM101C 1SM101D 2 1 12 240 1SM102C 1SM102D 4 1 12 240 1SM104C 1SM104D 6 1 12 240 1SM106C 1SM106D 10 1 12 240 1SM110C 1SM110D 16 1 12 240 1SM116C 1SM116D 20 1 12 240 1SM120C 1SM120D 25 1 12 240 1SM125C 1SM125D 32 1 12 240 1SM132C 1SM132D 40 1 12 240 1SM140C 1SM140D 50 1 12 240 1SM150C 1SM150D 63 1 12 240 1SM163C 1SM163D 80 1 8 120 1SM180C 1SM180D 100 1 8 120 1SM100C 1SM100D 125 1 8 120 1SM112C 1SM112D 2 2 6 120 1SM202C 1SM202D 4 2 6 120 1SM204C 1SM204D 6 2 6 120 1SM206C 1SM206D 10 2 6 120 1SM210C 1SM210D 16 2 6 120 1SM216C 1SM216D 20 2 6 120 1SM220C 1SM220D 25 2 6 120 1SM225C 1SM225D 32 2 6 120 1SM232C 1SM232D 40 2 6 120 1SM240C 1SM240D 50 2 6 120 1SM250C 1SM250D 63 2 3 60 1SM263C 1SM263D 80 2 4 60 1SM280C 1SM280D 100 2 4 60 1SM200C 1SM200D 125 2 4 60 1SM212C 1SM212D www.sigmaelektrik.com 21 MCB MINIATURE CIRCUIT BREAKERS C And D Tripping Curve EN 60898-1 10 kA MCB SND10000 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) 2 3 4 4 3 6 Order Code C Type D Type 80 1SM302C 1SM302D 4 80 1SM304C 1SM304D 3 4 80 1SM306C 1SM306D 10 3 4 80 1SM310C 1SM310D 16 3 4 80 1SM316C 1SM316D 20 3 4 80 1SM320C 1SM320D 25 3 4 80 1SM325C 1SM325D 32 3 4 80 1SM332C 1SM332D 40 3 4 80 1SM340C 1SM340D 50 3 4 80 1SM350C 1SM350D 63 3 4 80 1SM363C 1SM363D 80 3 2 40 1SM380C 1SM380D 100 3 2 40 1SM300C 1SM300D 125 3 2 40 1SM312C 1SM312D 2 4 3 60 1SM402C 1SM402D 4 4 3 60 1SM404C 1SM404D 6 4 3 60 1SM406C 1SM406D 10 4 3 60 1SM410C 1SM410D 16 4 3 60 1SM416C 1SM416D 20 4 3 60 1SM420C 1SM420D 25 4 3 60 1SM425C 1SM425D 32 4 3 60 1SM432C 1SM432D 40 4 3 60 1SM440C 1SM440D 50 4 3 60 1SM450C 1SM450D 63 4 3 60 1SM463C 1SM463D 80 4 2 20 1SM480C 1SM480D 100 4 2 20 1SM400C 1SM400D 125 4 2 20 1SM412C 1SM412D C Tripping Curve EN 60898-1 16 kA MCB SND16000 www.sigmaelektrik.com 22 Wiring Diagram Rated Current In (A) Number Of Poles Package (pcs.) Box (pcs.) Order Code 40 1 1 6 5SM140C 50 1 1 6 5SM150C 63 1 1 6 5SM163C 80 1 1 6 5SM180C 100 1 1 6 5SM100C 125 1 1 6 5SM125C