Page 1 of 31 EMC TEST REPORT for Sunway International Holdings Limited. Electronic Calculator Model Number: FC-100N Serial Number: E20110228-03-01/01 Prepared For: Sunway International Holdings Limited. Shiting Jiangkou Township, Putian City, Fujian Province, China Prepared By: Audix Technology (Shanghai) Co., Ltd. 3F 34Bldg 680 Guiping Rd., Caohejing Hi-Tech Park, Shanghai 200233, China Tel: Fax: +86-21-64955500 +86-21-64955491 Report Number : Date of Test : Date of Report : ACI-E11030 Mar 02, 2011 Mar 03, 2011 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 2 of 31 TABLE OF CONTENTS 1 2 3 4 5 6 7 8 9 Page SUMMARY OF STANDARDS AND RESULTS .......................................................................5 1.1 Description of Standards and Results ................................................................................................ 5 1.2 Description of Performance Criteria .................................................................................................. 6 GENERAL INFORMATION .......................................................................................................7 2.1 Description of EUT ............................................................................................................................ 7 2.2 Description of Test Facility................................................................................................................ 7 2.3 Measurement Uncertainty .................................................................................................................. 7 TEST EQUIPMENT .....................................................................................................................8 3.1 For Radiated Disturbance Test ........................................................................................................... 8 3.2 For Electrostatic Discharge Immunity Test ....................................................................................... 8 3.3 For RF Electromagnetic Field Immunity Test ................................................................................... 8 3.4 For Power Frequency Magnetic Field Immunity Test ....................................................................... 8 RADIATED DISTURBANCE TEST ...........................................................................................9 4.1 Block Diagram of Test Setup ............................................................................................................. 9 4.2 Applicable Standard ........................................................................................................................... 9 4.3 Limits for Radiated Disturbance ...................................................................................................... 10 4.4 EUT Configuration .......................................................................................................................... 10 4.5 Operating Condition of EUT............................................................................................................ 10 4.6 Test Procedure.................................................................................................................................. 11 4.7 Test Results ...................................................................................................................................... 11 ELECTROSTATIC DISCHARGE IMMUNITY TEST..........................................................14 5.1 Block Diagram of Test Setup ........................................................................................................... 14 5.2 Applicable Standard ......................................................................................................................... 14 5.3 Severity Levels and Performance Criterion ..................................................................................... 14 5.4 EUT Configuration .......................................................................................................................... 14 5.5 Operating Condition of EUT............................................................................................................ 14 5.6 Test Procedure.................................................................................................................................. 15 5.7 Test Results ...................................................................................................................................... 15 RF ELECTROMAGNETIC FIELD IMMUNITY TEST ........................................................17 6.1 Block Diagram of Test Setup ........................................................................................................... 17 6.2 Applicable Standard ......................................................................................................................... 17 6.3 Severity Levels and Performance Criterion ..................................................................................... 17 6.4 EUT Configuration .......................................................................................................................... 18 6.5 Operating Condition of EUT............................................................................................................ 18 6.6 Test Procedure.................................................................................................................................. 18 6.7 Test Results ...................................................................................................................................... 18 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST .......................................20 7.1 Block Diagram of Test Setup ........................................................................................................... 20 7.2 Applicable Standard ......................................................................................................................... 20 7.3 Severity Levels and Performance Criterion ..................................................................................... 20 7.4 EUT Configuration .......................................................................................................................... 21 7.5 Operating Condition of EUT............................................................................................................ 21 7.6 Test Procedure.................................................................................................................................. 21 7.7 Test Results ...................................................................................................................................... 21 DEVIATION TO TEST SPECIFICATIONS ...........................................................................23 PHOTOGRAPH ..........................................................................................................................24 9.1 Radiated Disturbance Test ............................................................................................................... 24 9.2 Electrostatic Discharge Immunity Test ............................................................................................ 25 9.3 RF Electromagnetic Field Immunity Test ........................................................................................ 26 9.4 Power Frequency Magnetic Field Immunity Test ............................................................................ 27 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 3 of 31 APPENDIX PHOTOGRAPHS OF EUT.............................................................................................28 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 4 of 31 TEST Applicant Telephone Manufacturer EUT Description : : : : REPORT Sunway International Holdings Limited. +86-594-3785651 Sunway International Holdings Limited. Electronic Calculator (A) Model Number : FC-100N (B) Serial Number : E20110228-03-01/01 (C) Power Supply : DC 1.5V (Button Battery + Solar) Test Standard Used: EN 55022:2006+A1:2007 (CISPR 22:2005+A1:2005), EN55024:1998+A1:2001+A2:2003 (CISPR 24:1997+A1:2001+A2:2002) (IEC61000-4-2:2001, IEC61000-4-3: 2006, IEC 61000-4-8:2001) The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to determine the maximum emission levels emanating from the device and the severity levels of the device can endure and its performance criterion. The test results are contained in this test report and Audix Technology (Shanghai) Co., Ltd. is assumed full responsibility for the accuracy and completeness of all these testing. This report shows that the EUT (Equipment Under Test) is technically compliance with the EN 55022 and EN 55024 requirements also. This report is applied to above tested sample only and shall not be reproduced in part without written approval of Audix Technology (Shanghai) Co., Ltd. Other susceptibility tests and relevant emission tests as specified in the concerned standards are omitted and regarded as compliance due to the nature of the product using our engineering judgment. Date of Test : Mar 02, 2011 Date of Report : Mar 03, 2011 Producer : KATHY WANG / Assistant Review : DIO YANG / Deputy Assistant Manager Signatory : SAMMY CHEN / Deputy Manager Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 5 of 31 1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard Limits Results Conducted Disturbance at the Mains Terminal Conducted Common Mode Disturbance at Telecommunication Port EN 55022:2006+A1:2007 (CISPR 22:2005+A1:2005) N/A N/A EN 55022:2006+A1:2007 (CISPR 22:2005+A1:2005) N/A N/A EN 55022:2006+A1:2007 Class B Pass (CISPR 22:2005+A1:2005) EN 61000-3-2:2006 Harmonic Current Emission N/A N/A (IEC 61000-3-2:2005) Voltage Fluctuations and EN 61000-3-3:1995+A1:2001+A2:2005 N/A N/A Flicker (IEC 61000-3-3:1994+A1:2001+A2:2005) IMMUNITY (EN 55024:1998+A1:2001+A2:2003) (CISPR 24:1997+A1:2001+A2:2002) Performance Description of Test Item Basic Standard Results Criteria Electrostatic Discharge (ESD) IEC 61000-4-2:2001 B Pass Radio-frequency, Continuous IEC 61000-4-3:2006 A Pass Radiated Disturbance IEC 61000-4-4:2004 Electrical Fast Transient (EFT) N/A N/A +Corr.1:2006+Corr.2:2007 Surge IEC 61000-4-5:2005 N/A N/A Radio-frequency, Continuous IEC 61000-4-6:2006 N/A N/A Conducted Disturbance Power Frequency Magnetic IEC 61000-4-8:2001 A Pass Field Voltage Dips, >95% Reduction N/A N/A IEC 61000-4-11:2004 Voltage Dips, 30% Reduction N/A N/A Voltage Interruptions N/A N/A N/A is an abbreviation for Not Applicable. Radiated Disturbance Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 6 of 31 1.2 Description of Performance Criteria The variety and the diversity of the apparatus within the scope of this standard make it difficult to define precise criteria for the evaluation of the immunity test results. If, as result of the application of the tests defined in this standard, the apparatus becomes dangerous or unsafe, the apparatus shall be deemed to have failed the test. A functional description and a definition of performance criteria, during or as a consequence of the EMC testing, shall be provided by the manufacturer and noted in the test report, based on the following criteria: 1.2.1 Performance criterion A The apparatus shall continue to operate as intended during the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. 1.2.2 Performance criterion B The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed however. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. 1.2.3 Performance criterion C Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls, or by any operation specified in the instructions for use. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 7 of 31 2 GENERAL INFORMATION 2.1 Description of EUT Description : Electronic Calculator Model No. : FC-100N Serial No. : E20110228-03-01/01 Power Supply : DC 1.5V (Button Battery + Solar) Applicant : Sunway International Holdings Limited. Shiting Jiangkou Township, Putian City, Fujian Province, China Manufacturer : Sunway International Holdings Limited. Shiting Jiangkou Township, Putian City, Fujian Province, China 2.2 Description of Test Facility Name of Firm : Audix Technology (Shanghai) Co., Ltd. Site Location : 3F 34Bldg 680 Guiping Rd, Caohejing Hi-Tech Park, Shanghai 200233, China Accredited by NVLAP, Lab Code : 200371-0 TAF Accreditation Number : 1417 2.3 Measurement Uncertainty Radiated Disturbance Expanded Uncertainty : U = 3.02 dB Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 8 of 31 3 TEST EQUIPMENT 3.1 For Radiated Disturbance Test Item Type 1. Test Receiver Manufacturer R&S Model No. ESVS10 Serial No. Last Cal. Next Cal. 844594/001 Mar 07, 2010 Mar 07, 2011 2944A10548 Sep 19, 2010 Mar 19, 2011 2. Preamplifier Agilent 8447D 3. Bi-log Antenna TESEQ CBL6112D 4. Spectrum Agilent E7405A 5. Software Audix E3 23192 Dec 01, 2010 Dec 01, 2011 MY45106600 May 19, 2010 May 19, 2011 SET00200 --9912M295-2 3.2 For Electrostatic Discharge Immunity Test Item Type 1. ESD Simulator Manufacturer TESEQ Model No. NSG 437 Serial No. 130 Last Cal. Next Cal. Nov 26, 2010 Nov 26, 2011 3.3 For RF Electromagnetic Field Immunity Test Item Type Manufacturer Model No. Serial No. Last Cal. Next Cal. 1. Signal Generator Agilent E4421B MY43350935 Apr 02, 2010 Apr 02, 2011 2. Power Amplifier AR KAW2180 10088-1 Apr 02, 2010 Apr 02, 2011 Log-Periodic 3. AR AT-4002A 309732 Jan 24, 2011 Jan 24, 2012 Antenna Dual Directional 4. AR DC6180 19326 Jan 24, 2011 Jan 24, 2012 Coupler (DDC) 5. Power Meter HP 438A 2517A02731 Apr 02, 2010 Apr 02, 2011 6. Power Sensor HP 8481D 3318A13765 Apr 06, 2010 Apr 06, 2011 7. Field Probe AR FP2036 308920 May 14, 2010 May 14, 2011 8. Field Monitor AR FM2000 19221 Oct 29, 2010 Oct 29, 2011 3.4 For Power Frequency Magnetic Field Immunity Test Item Type Manufacturer Model No. EMC Immunity 1. KeyTek CE Master test system p-f Magnetic Field F-1000-4-8/9/ 2. FCC Loop 10-1M Serial No. Last Cal. Next Cal. 9609367 Apr 02, 2010 Apr 02, 2011 13 Apr 02, 2010 Apr 02, 2011 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 9 of 31 4 RADIATED DISTURBANCE TEST 4.1 Block Diagram of Test Setup 4.1.1 Radiated emission test setup ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS EUT 3.0 METERS FRP TABLE PREAMPLIFIER 0.8 m SPECTRUM ANALYZER TEST RECEIVER : 50 ohm Coaxial Switch 4.2 Applicable Standard EN 55022:2006+A1:2007 (CISPR 22:2005+A1:2005) (Class B) Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 10 of 31 4.3 Limits for Radiated Disturbance All emanations from a Class B computing devices or system including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: Frequency (MHz) Distance (m) Field Strength Limits dB(μV/m) Converted Field Strength Limits By 3 Meters Measuring Distance dB(μV/m) 30 ~ 230 10 30 40 230 ~ 1000 10 37 47 NOTE 1 - The tighter limit applies at the edge between two frequency bands. NOTE 2 – Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system. NOTE 3 – Audix Technology (Shanghai) Co., Ltd. Only has a 3 meters Semi-anechoic Chamber to do the radiated test, therefore, Audix Shanghai used 3 meters measuring distance and converted limits to judge the EUT compliance with or not. 4.4 EUT Configuration The EUT (listed in Sec. 2.1) was installed as shown as Sec. 4.1 to meet EN 55022 requirement and operating in a manner which tends to maximize its emission level in a normal application. 4.5 Operating Condition of EUT 4.5.1 Set up the EUT as shown on Sec. 4.1 4.5.2 Turn on the power of the EUT. 4.5.3 Set the EUT on the test mode (Display ‘8’ full of screen), and then test. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 11 of 31 4.6 Test Procedure The EUT was placed upon a FRP turntable 0.8 m above the horizontal metal ground plane. The FRP turntable rotated 360 degrees to determine the position of the maximum emission level. The EUT was set 3 meters away from the receiving antenna, which was mounted on an antenna tower. The antenna moved up and down between 1 meter and 4 meters to find out the maximum emission level. Broadband antenna (Calibrated Bilog Antenna) was used as receiving antenna. Both horizontal and vertical polarizations of the antenna were set on measurement. In order to find the maximum emission, all of interface cables were manipulated according to EN 55022:2006+A1:2007 (CISPR 22:2005+A1:2005) (Class B) requirements during radiated test. The I.F bandwidth of R&S Test Receiver ESVS10 was set at 120 kHz. The frequency range from 30 MHz to 1000 MHz was checked. All the tests (Display ‘8’ full of screen) results are listed in Sec.4.7. 4.7 Test Results <PASS> All the following records are the disturbance levels and the frequencies of the highest disturbances, and if the disturbance not reported below are too low against the prescribed converted 3 meters limits. Refer to the following pages. NOTE 1 – All reading are Quasi-Peak values. NOTE 2 – 0° was the table front facing the antenna. Degree is calculated from 0° clockwise facing the antenna. NOTE 3 – All Quasi-Peak values are background value only. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 12 of 31 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 13 of 31 Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 14 of 31 5 ELECTROSTATIC DISCHARGE IMMUNITY TEST 5.1 Block Diagram of Test Setup 5.1.1 Electrostatic Discharge Immunity test setup ELECTRONIC CALCULATOR ESD SIMULATOR 5.2 Applicable Standard EN 55024:1998+A1:2001+A2:2003 (CISPR 24:1997+A1:2001+A2:2002) (IEC 61000-4-2:2001, Contact Discharge: ± 2kV, ± 4kV, Air Discharge: ± 2kV, ± 4kV, ± 8kV) 5.3 Severity Levels and Performance Criterion 5.3.1 Severity levels Level 1. Test Voltage Contact Discharge Air Discharge (kV) (kV) 2 2 2. 4 4 3. 6 8 4. 8 15 Special Special X 5.3.2 Performance criterion: A 5.4 EUT Configuration The EUT (listed in Sec. 2.1) was installed as shown as Sec. 5.1 to meet IEC 61000-4-2 requirement and operating in a manner which tends to maximize its performance criterion in a normal application. 5.5 Operating Condition of EUT 5.5.1 Setup the EUT on the reference plane in a shielded room as Sec. 5.1, and operate them as Sec. 4.5. 5.5.2 Single discharges were applied on the most sensitive points of the EUT, and to the horizontal and vertical coupling plane at points. 5.5.3 Check the effects of test. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 15 of 31 5.6 Test Procedure The test applied a non-conductive surface and a horizontal coupling plane on a wooden table, 0.8 m high, standing on the reference ground plane, which is a 2 m x 3 m metallic sheet with 1.5 mm thickness. This reference ground plane projected beyond the EUT by at least 0.5 m on all sides and the minimum distance between the EUT and all other conductive structure, except the ground plane beneath the EUT, was more than 1.0 m. 5.6.1 Contact Discharge The tip of the discharge electrode should touch the EUT, before the discharged switch was operated. The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test points (a minimum of 50 discharges at each point). One of the test points shall be subjected to at least 50 indirect discharges (contact) to the center of the front edge of the horizontal coupling plane. If no direct contact test points are available, then at least 200 indirect discharge shall be applied in the indirect mode (use of the Vertical Coupling Plane) 5.6.2 Horizontal Coupling Plane (HCP) More than 50 single discharges were applied at the front edge of each HCP opposite the center point of the EUT and 0.1mm from vertically the front of the EUT. Discharge to the HCP was made horizontal to the edge of the HCP. 5.6.3 Vertical Coupling Plane (VCP) More than 50 single discharges were applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5 m x 0.5 m, was placed parallel to, and positioned at a distance of 0.1 m from the EUT. Discharges were applied to the coupling plane, with this plane in sufficient different positions that all sides of the EUT were completely illuminated. 5.6.4 Air Discharge The round discharge tip of the discharge electrode was approached as fast as possible to touch the EUT. After each discharge, the ESD simulator (discharge electrode) was removed from the EUT. The simulator was then re-trigged for a new single discharge and applies more than 10 times on each reselected point. This procedure was repeated until the air discharge completed. 5.7 Test Results <PASS> Refer to the following pages. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 16 of 31 Electrostatic Discharge Immunity Test Result Audix Technology (Shanghai) Co., Ltd. Applicant : Sunway International Holdings Limited. Test Date EUT : Electronic Calculator Temperature : 23℃ M/N : FC-100N Humidity : 55% RH S/N : E20110228-03-01/01 Atmospheric Pressure : 101.3 kPa DC 1.5V (Button Battery + Solar) Test Mode Display ‘8’ full of screen Power Supply : : : Mar 02, 2011 Contact Discharge Voltage: ± 2kV; ± 4kV Air Discharge Voltage: ± 2kV; ± 4kV; ± 8kV Contact Discharge: For each point positive 25 times and negative 25 times discharge Air Discharge: For each point positive 10 times and negative 10 times discharge Location Point(s) Kind Result Around the EUT 4 C (VCP) PASS Around the EUT 4 C (HCP) PASS Screws 3 C PASS NOTE 1 – C (Contact Discharge), A (Air Discharge) NOTE 2 – HCP (Horizontal Coupling Plane), VCP (Vertical Coupling Plane) Test Equipment: ; ESD Simulator : TESEQ NSG 437 TEST ENGINEER: JOE YE Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 17 of 31 6 RF ELECTROMAGNETIC FIELD IMMUNITY TEST 6.1 Block Diagram of Test Setup 6.1.1 RF Electromagnetic Field Immunity test setup 3m FULL ANECHOIC CHAMBER EUT 1.5 m 0.8 m DUAL DIRECTIONAL COUPLER POWER POWER METER SENSOR POWER AMPLIFIER SIGNAL GENERATOR 6.2 Applicable Standard EN 55024:1998+A1:2001+A2:2003 (CISPR 24:1997+A1:2001+A2:2002) (IEC 61000-4-3: 2006, Frequency Range: 80 - 1000 MHz, Field Strength: 3 V/m, Modulation: 80% AM 1 kHz) 6.3 Severity Levels and Performance Criterion 6.3.1 Severity levels 1. Field Strength V/m 1 2. 3 3. 10 Level X Special 6.3.2 Performance criterion: A Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 18 of 31 6.4 EUT Configuration The EUT (listed in Sec. 2.1) was installed as shown as Sec. 6.1 to meet IEC 61000-4-3 requirement and operating in a manner which tends to maximize its performance criterion in a normal application. 6.5 Operating Condition of EUT 6.5.1 Setup the EUT on the table in an anechoic chamber as Sec. 6.1, and operated them as Sec. 4.5. 6.5.2 The test was performed with the transmitting antenna facing 4 sides of the EUT. 6.5.3 Check the effects of the test. 6.6 Test Procedure The EUT was placed on a wooden table, 0.8 m high, standing on the ground reference plane. The power meter was used to measure the forward power. The EUT was set 3 m from the transmitting antenna. Both horizontal and vertical polarization of the antenna was set on test. Each side of the EUT was faced to the transmitting antenna and measured individually. A CCD camera was put inside the chamber and through its display to monitor the operational situation of the EUT to judge the EUT performance criterion during test. The frequency range is swept from 80 MHz to 1000 MHz. All the scanning conditions are as follows: Condition of Test -----------------------------Fielded Strength Modulation Scanning Frequency Dwell Time Remarks --------------------------------3 V/m (Severity Level 2) 80% AM 1 kHz 80 - 1000 MHz 3 sec. 6.7 Test Results <PASS> Refer to the following pages. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 19 of 31 RF Field Strength Susceptibility Immunity Test Result Audix Technology (Shanghai) Co., Ltd. Applicant : Sunway International Holdings Limited. Test Date EUT : Electronic Calculator Temperature : 23℃ M/N : FC-100N Humidity : 52% RH S/N : E20110228-03-01/01 Atmospheric Pressure : 101.3 kPa Power Supply : DC 1.5V (Button Battery + Solar) Field Strength : 3 V/m Test Mode Display ‘8’ full of screen Modulation Pulse : : : Mar 02, 2011 Frequency Range 80 MHz to 1000 MHz 900 MHz Modulation 80% AM 1 kHz ----- Steps 1% 1 kHz Dwell Time 3s ----- Antenna Polarization ; AM Horizontal Vertical Horizontal Vertical Front PASS PASS -- -- Rear PASS PASS -- -- Right EUT Position Left PASS PASS -- -- PASS PASS -- -- Floor PASS PASS -- -- Top PASS PASS -- -- NOTE - “--” means the item is no applicable. Test equipment: ; ; ; ; Signal Generator Power Amplifier Power Meter Log-Periodic Antenna : : : : Agilent E4421B AR KAW2180 HP 438A AR AT4002A ; ; ; ; DDC Power Sensor Field Probe Field Monitor : : : : AR DC6180 HP 8481D AR FP2036 AR FM2000 TEST ENGINEER: TERRY HOU Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 20 of 31 7 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST 7.1 Block Diagram of Test Setup 7.1.1 Power Frequency Magnetic Field Immunity test setup EMC IMMUNITY TEST SYSTEM EUT INSULATING SUPPORT 0.1m GROUNDING CABLE 0.8m GROUNDING CABLE GROUND REFERENCE PLANE 7.2 Applicable Standard EN 55024:1998+A1:2001+A2:2003 (CISPR 24:1997+A1:2001+A2:2002) (IEC 61000-4-8: 2001, Magnetic field strength: 1A/m) 7.3 Severity Levels and Performance Criterion 7.3.1 Severity level: Test Level Magnetic field strength A/m 1 2 3 4 5 X 1 3 10 30 100 Special 7.3.2 Performance criterion: A Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 21 of 31 7.4 EUT Configuration The EUT was placed on the ground reference plane with the interposition of a 0.1m thickness insulating support. The ground plane is aluminum of 0.25 mm thickness; the size of the ground plane is 1m × 1m. The induction coil was rotated by 90º in order to expose the EUT to the test field with different orientations. 7.5 Operating Condition of EUT Refer to Sec. 4.5. 7.6 Test Procedure The EUT placed on high 1m table that above the ground reference plane which the min. size 1m × 1m and 0.65mm thickness metallic, and subjected to the test magnetic field by using the induction coil of standard dimensions (1m × 1m). The induction coil rotated by 90 degrees in order to expose the EUT to the test field with different orientations. All cables of EUT exposed to magnetic field for 1m of their length. 7.7 Test Results <PASS> Refer to the following pages. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 22 of 31 Power Frequency Magnetic Field Immunity Test Result Audix Technology (Shanghai) Co., Ltd. Applicant : Sunway International Holdings Limited. Test Date EUT : Electronic Calculator Temperature : 23℃ M/N : FC-100N Humidity : 55% RH S/N : E20110228-03-01/01 Atmospheric Pressure : 101.3 kPa Test Mode Display ‘8’ full of screen Power Supply : Test Level (A/m) DC 1.5V (Button Battery + Solar) Testing Duration (in second) : Mar 02, 2011 : Coil Orientation Criterion Result 1 120 Axis-X A PASS 1 120 Axis-Y A PASS 1 120 Axis-Z A PASS Test Instrumentation: ; EMC Immunity Test System ; P-f Magnetic Field Loop : : KeyTek CE Master FCC F-1000-4-8/9/10-1M TEST ENGINEER: JOE YE Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 23 of 31 8 DEVIATION TO TEST SPECIFICATIONS None. Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 24 of 31 9 PHOTOGRAPH 9.1 Radiated Disturbance Test FRONT VIEW OF RADIATED EMISSION TEST BACK VIEW OF RADIATED EMISSION TEST Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 25 of 31 9.2 Electrostatic Discharge Immunity Test DIRECT DISCHARGE INDIRECT DISCHARGE Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 26 of 31 9.3 RF Electromagnetic Field Immunity Test FRONT VIEW BACK VIEW Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 27 of 31 VIEW IN MONITOR 9.4 Power Frequency Magnetic Field Immunity Test Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 28 of 31 APPENDIX PHOTOGRAPHS OF EUT Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 29 of 31 FIGURE 1 ELECTRONIC CALCULATOR (M/N: FC-100N) GENERAL APPEARANCE (FRONT VIEW) FIGURE 2 ELECTRONIC CALCULATOR (M/N: FC-100N) GENERAL APPEARANCE (BACK VIEW) Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 30 of 31 FIGURE 3 ELECTRONIC CALCULATOR (M/N: FC-100N) COVER REMOVED Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030 Page 31 of 31 FIGURE 4 ELECTRONIC CALCULATOR (M/N: FC-100N) MAIN BOARD (COMPONENT SIDE) FIGURE 5 ELECTRONIC CALCULATOR (M/N: FC-100N) MAIN BOARD (SOLDERED SIDE) Audix Technology (Shanghai) Co., Ltd. Report No.: ACI-E11030