DYRTP366, DYRTP486 Revised 10/17/14 Page 1/4 Document # PG04-007 Discovery® 36” and 48” Wide Slide-in Gas Rangetops ELECTRIC CIRCUIT REQUIREMENTS WARNING • • PLANNING GUIDE Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Circuit Required Total Connected Load 120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5” Water Column 6” Water Column Propane (LP) 10” Water Column 11” Water Column * Maximum gas supply pressure for all models is 1/2 psi IMPORTANT: Installation of a non-combustible material (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the rangetop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609 (DYRTP366) or AEB4809 (DYRTP486). Consult local codes and ordinances for acceptable non-combustible materials. A Combustible rear wall PRODUCT DIMENSIONS - ISO VIEW 2 1/2” (6.4 cm) min. to combustible rear wall A - Width DYRTP366 35 7/8” (91.1 cm) DYRTP486 47 7/8” (121.6 cm) Trim: 1/4” (6.4 mm) thick 27 5/16” (69.4 cm) 26 5/16” (66.8 cm) 25 3/8” (64.5 cm) 1 1/4” (3.2 cm) cooking surface height (grate level) above countertop 3 3/8” (8.6 cm) Power cord 40” long CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD Combustible rear wall Backguard mandatory if gap from back of cooktop to combustible wall is less than 2 1/2” 7 3/4” (19.7 cm) 7/16” (1.1 cm) 3/4” NPT gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (5.1 cm) from chassis bottom CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD PRODUCT DIMENSIONS - SIDE VIEW All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DYRTP366, DYRTP486 Revised 10/17/14 Page 2/4 Document # PG04-007 Discovery 36” and 48” Wide Slide-in Gas Rangetops PLANNING GUIDE Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted. 10” (25.4 cm) to combustible side wall min. both sides 1 1/2” (3.8 cm) typical countertop thickness 1/2” (1.3 cm) overhang, both sides B Mounting platform 1” (2.5 cm) min. thickness 7 3/4” (19.7 cm) Recommended gas and electrical service location, consult local code 36” (91.4 cm) typical CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW 13” (33.0 cm) max.3 C Model No. B C DYRTP366 36” (91.4 cm) 36” (91.4 cm)* 42” (106.7 cm)** DYRTP486 48” (121.9 cm) 48” (121.9 cm)* 54” (137.2 cm)** * Minimum ** Recommended See note 2 15” (40.6 cm) min.1, 3 30” (76.2 cm) min.1 Cutout for utility access Top of finished counter Grate level Grate level CABINET/COUNTERTOP DIMENSIONS ISO VIEW 1 Vertical to combustible surface from rangetop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the rangetop. All specifications subject to change without notice. www.dacor.com continued on following pages... Phone: (800) 793-0093 DYRTP366, DYRTP486 Revised 10/17/14 Page 3/4 Document # PG04-007 Discovery 36” and 48” Wide Slide-in Gas Rangetops PLANNING GUIDE Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated 24” (61.0 cm) Cabinet face Gas and electrical connections at right rear section of chassis Installed control panel overhang 1/3/8” (3.5 cm) Countertop Mounting platform INSTALLED RANGETOP - SIDE VIEW Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2” (6.4 cm) min. for combustible rear wall above countertop Non-combustible rear wall, rear of mounting platform 10” (25.4 cm) min. to combustible wall above countertop, both sides 3/8” (1.3 cm) countertop overhang Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (20.3 cm X 15.2 cm), if gas and electrical are routed through bottom CL Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts Countertop 11 7/16” (29.1 cm) Cabinet face below countertop overhang 1/2” (1.3 cm) countertop overhang Countertop 24” (63.5 cm) min. cabinet depth 1/2” (1.3 cm) countertop overhang 1” (2.5 cm) thick mounting platform min. D CL 2” (5.1 cm) Counterop overhang 1” (2.5 cm) typical 1 3/8” (3.5 cm) max. D CL CL B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW Model No. B - Cutout Width D - Hole Offset DYRTP366 36” (91.4 cm) 16 5/8” (42.2 cm) DYRTP486 48” (121.9 cm) 20 13/16” (52.9 cm) All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093 DYRTP366, DYRTP486 Revised 10/17/14 Page 4/4 Document # PG04-007 Discovery 36” and 48” Wide Slide-in Gas Rangetops PLANNING GUIDE Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated Non combustible rear wall recommended 3/8” (1.0 cm) min. countertop overhang E Open to below to allow for raised vent, gas and electrical connections 2 5/8” (6.7 cm) 1/2” (1.3 cm) countertop overhang CL 11 7/16” (29.1 cm) Countertop 15” (38.1 cm) 1/2” (1.3 cm) countertop overhang 1” (2.5 cm) thick mounting platform min. Cabinet face below countertop overhang Countertop 26 5/8” (67.6 cm) min. cabinet depth 10” (2.5 cm) min. to combustible wall above countertop, both sides Hole 1/2” dia. (1.3 cm), 2 places, through platform for hold down bolts D 2” (5.1 cm) Counterop overhang 1” (2.5 cm) typical 1 3/8” (3.5 cm) max. D CL CL CL B CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW 3/8” min. (1.0 cm) flat countertop overhang required behind cutout Countertop Stiffener 3/8” min. (1.0 cm) space behind downdraft vent chassis to clear stiffener Dacor approved downdraft vent DYRTP366 or DYRTP486 rangetop Model No. Approved Downdraft Vent Models DYRTP366 ERV36, ERV3615, PRV36 DYRTP486 ERV48, PRV48 IMPORTANT: Use only the downdraft vents specified. Control panel overhang 1 3/8” (3.5 cm) Cabinet face Minimum countertop height: 30 1/4" (76.8 cm) Model No. B - Cutout Width D - Hole Offset E - Downdraft Vent Cutout DYRTP366 36” (91.4 cm) 16 5/8” (42.2 cm) 33 1/2” (85.1 cm) DYRTP486 48” (121.9 cm) 20 13/16” (52.9 cm) 43 1/2” (110.5 cm) IMPORTANT: See downdraft installation instructions for duct system layout/planning CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - SIDE VIEW All specifications subject to change without notice. www.dacor.com Phone: (800) 793-0093