Planning Guide

advertisement
DYRTP366, DYRTP486
Revised 10/17/14 Page 1/4
Document # PG04-007
Discovery®
36” and 48” Wide
Slide-in Gas Rangetops
ELECTRIC CIRCUIT REQUIREMENTS
WARNING
•
•
PLANNING
GUIDE
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
This appliance must be installed in accordance with the
accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
IMPORTANT: Installation of a non-combustible material (up to the hood) or
a backsplash is always recommended, and mandatory if the distance to the
back wall from the rangetop is less than 2 1/2” (Figure 2). When installing
a backguard, use only Dacor model numbers AEB3609 (DYRTP366) or
AEB4809 (DYRTP486). Consult local codes and ordinances for acceptable
non-combustible materials.
A
Combustible
rear wall
PRODUCT DIMENSIONS - ISO VIEW
2 1/2” (6.4 cm) min. to
combustible rear wall
A - Width
DYRTP366
35 7/8” (91.1 cm)
DYRTP486
47 7/8” (121.6 cm)
Trim:
1/4”
(6.4 mm)
thick
27 5/16” (69.4 cm)
26 5/16” (66.8 cm)
25 3/8” (64.5 cm)
1 1/4” (3.2 cm) cooking surface
height (grate level) above
countertop
3 3/8”
(8.6 cm)
Power cord
40” long
CABINET/COUNTERTOP SIDE VIEW WITHOUT BACKGUARD
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
7 3/4”
(19.7 cm)
7/16”
(1.1 cm)
3/4” NPT gas inlet, connects to regulator
from bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
CABINET/COUNTERTOP SIDE VIEW WITH BACKGUARD
PRODUCT DIMENSIONS - SIDE VIEW
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
DYRTP366, DYRTP486
Revised 10/17/14 Page 2/4
Document # PG04-007
Discovery 36” and 48” Wide
Slide-in Gas Rangetops
PLANNING
GUIDE
Cabinet tolerances: +1/16” (+1.6 mm), -0 unless otherwise noted.
10” (25.4 cm) to
combustible side
wall min. both sides
1 1/2” (3.8 cm)
typical countertop
thickness
1/2” (1.3 cm)
overhang,
both sides
B
Mounting platform
1” (2.5 cm) min.
thickness
7 3/4”
(19.7 cm)
Recommended
gas and electrical
service location,
consult local code
36” (91.4 cm)
typical
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
13” (33.0 cm)
max.3
C
Model No.
B
C
DYRTP366
36” (91.4 cm)
36” (91.4 cm)*
42” (106.7 cm)**
DYRTP486
48” (121.9 cm)
48” (121.9 cm)*
54” (137.2 cm)**
* Minimum ** Recommended
See note 2
15” (40.6 cm)
min.1, 3
30” (76.2 cm)
min.1
Cutout for
utility access
Top of
finished
counter
Grate
level
Grate
level
CABINET/COUNTERTOP DIMENSIONS ISO VIEW
1 Vertical to combustible surface from rangetop grate level;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2 See Cabinet/Countertop Dimensions - Top View
3 This specification not applicable for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the rangetop.
All specifications subject to change without notice.
www.dacor.com
continued on following pages...
Phone: (800) 793-0093
DYRTP366, DYRTP486
Revised 10/17/14 Page 3/4
Document # PG04-007
Discovery 36” and 48” Wide
Slide-in Gas Rangetops
PLANNING
GUIDE
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
24” (61.0 cm)
Cabinet
face
Gas and electrical connections at
right rear section of chassis
Installed control
panel overhang
1/3/8” (3.5 cm)
Countertop
Mounting platform
INSTALLED RANGETOP - SIDE VIEW
Gas connection and power cord may be
routed through bottom or back of chassis
Increase countertop and overhang
additional 2 1/2” (6.4 cm) min. for
combustible rear wall above
countertop
Non-combustible
rear wall, rear of
mounting platform
10” (25.4 cm) min.
to combustible wall
above countertop,
both sides
3/8” (1.3 cm)
countertop overhang
Gas/electrical utility cut-out in right rear corner of
mounting platform 8” W X 6” D (20.3 cm X 15.2 cm),
if gas and electrical are routed through bottom
CL
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
Countertop
11 7/16”
(29.1 cm)
Cabinet face
below countertop
overhang
1/2” (1.3 cm)
countertop
overhang
Countertop
24”
(63.5 cm)
min.
cabinet
depth
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
D
CL
2” (5.1 cm)
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
D
CL
CL
B
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW
Model No.
B - Cutout Width
D - Hole Offset
DYRTP366
36” (91.4 cm)
16 5/8” (42.2 cm)
DYRTP486
48” (121.9 cm)
20 13/16” (52.9 cm)
All specifications subject to change without notice.
www.dacor.com
Phone: (800) 793-0093
DYRTP366, DYRTP486
Revised 10/17/14 Page 4/4
Document # PG04-007
Discovery 36” and 48” Wide
Slide-in Gas Rangetops
PLANNING
GUIDE
Cutout tolerances: +1/16” (+1.6 mm), -0 unless otherwise stated
Non combustible rear
wall recommended
3/8” (1.0 cm) min.
countertop overhang
E
Open to below to allow for raised
vent, gas and electrical connections
2 5/8”
(6.7 cm)
1/2” (1.3 cm)
countertop
overhang
CL
11 7/16”
(29.1 cm)
Countertop
15”
(38.1 cm)
1/2” (1.3 cm)
countertop
overhang
1” (2.5 cm) thick mounting platform min.
Cabinet face
below countertop
overhang
Countertop
26 5/8”
(67.6 cm)
min.
cabinet
depth
10” (2.5 cm) min. to
combustible wall
above countertop,
both sides
Hole 1/2” dia. (1.3 cm),
2 places, through platform
for hold down bolts
D
2” (5.1 cm)
Counterop
overhang
1” (2.5 cm)
typical
1 3/8”
(3.5 cm)
max.
D
CL
CL
CL
B
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
Countertop
Stiffener
3/8” min. (1.0 cm)
space behind
downdraft vent
chassis to clear
stiffener
Dacor approved
downdraft vent
DYRTP366 or
DYRTP486 rangetop
Model No.
Approved Downdraft
Vent Models
DYRTP366
ERV36, ERV3615, PRV36
DYRTP486
ERV48, PRV48
IMPORTANT: Use only the downdraft vents specified.
Control panel
overhang
1 3/8” (3.5 cm)
Cabinet face
Minimum
countertop
height:
30 1/4"
(76.8 cm)
Model No.
B - Cutout
Width
D - Hole
Offset
E - Downdraft
Vent Cutout
DYRTP366
36”
(91.4 cm)
16 5/8”
(42.2 cm)
33 1/2”
(85.1 cm)
DYRTP486
48”
(121.9 cm)
20 13/16”
(52.9 cm)
43 1/2”
(110.5 cm)
IMPORTANT: See downdraft
installation instructions for
duct system layout/planning
CABINET/COUNTERTOP CUTOUT DIMENSIONS
WITH DOWNDRAFT VENT - SIDE VIEW
All specifications subject to change without notice.
www.dacor.com