www.opendomo.com ODEnergy rev.19.1 2015 IP Smart Energy Meter ODEnergy Opendomo Cloud ODEnergy Your electrical facility Internet Smartphone or Computer Characteristics of the models Model System Connectivity ODEnergy ME Single-phase Ethernet ODEnergy MEW Single-phase Ethernet + WIFI ODEnergy TE Single-phase/three-phase Ethernet ODEnergy TEW Single-phase/three-phase Ethernet + WIFI Note: WIFI + Ethernet versions allow only one of the two connections at once. Equipment characteristics _ _ _ _ _ _ _ _ _ _ Values measured: Active Power (KW), Reactive power (Kvar), Apparent power (KVA), cos phi, Volts, Amperes. Supply voltage: From 85 to 265V AC Grid frequency 47-80 Hz. A supply voltage of 230 V ± 15% and 50-60 Hz is recommended to maintain high accuracy. Equipment consumption: 5 VA Relative error: 1% Maximum power measured: 2,147 GW Maximum energy measured: 2147 Gwh Ethernet Connectivity: 10Base-T with Rj45 connector. WIFI Connectivity: Compatible with 802.11b / g / n networks, Output Power: 10dBm, receiver sensitivity: -91dBm, supports WEP, WPA-PSK, WPA-2-PSK. Box sizes: 86x53x58 mm. DIN rail format: 3 units to be installed on any standard electrical box. Memory size: 48 hours (1). 1. ODEnergy has an internal memory allowing you to store data (for sending frequency every 15 minutes) in case internet access is lost. APPLICATIONS _ _ _ _ _ _ 1 Monitoring of the main electrical consumption. Monitoring of multi-site electrical consumption. Load controller. Data logger. Site monitoring through internet. Alarm generator of over-consumption. © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 TABLE OF MEASURED VARIABLES Variable Unit L1 active power in watts / hour Wh L2 active power in watts / hour Wh L3 active power in watts / hour Wh L1 reactive power in volt-amperes reactives / hour varh L2 reactive power in volt-amperes reactives / hour varh L3 reactive power in volt-amperes reactives / hour varh L1 active power in watts W L2 active power in watts W L3 Active power in watts W L1 reactive power in volt-amperes reactives var L2 reactive power in volt-amperes reactives var L3 reactive power in volt-amperes reactives var L1 phase voltage in volts V L2 phase voltage in volts V L3 phase voltage in volts V L1 current in milliamps mA L2 current in milliamperes mA L3 current in milliamps mA You can see all the variables of the table asynchronously reading an XML document generated on the device itself at: http://DEVICE_IP/data.xml For example: http://169.254.0.4/data.xml It is not recommended to exceed the rate of one reading every 5 seconds. If the data is sent to the OpenDomo Cloud you will have to access more variables that are not on the list, however if these data are read from a third party application, you can easily calculate other quantities: Power factor or cosine fi: Example: fdp = active power / apparent power Apparent power: Example: P = Voltage * Current Active power phase: Example: S3 = Active power L1 + Active Power L2 + Active power L3 Reactive power phase: Example: Q3 = Reactive power L1 + Reactive power L2 + Reactive power L3 2 © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Description ODEnergy is an energy meter in real-time with IP connection via Ethernet or via WIFI. Given the flexibility provided by this type of connection and simplicity at the same time, access is possible to the product from any Internet connected device and, therefore, monitor the energy consumption of your electrical installation with OpenDomo Cloud. You must perform all operations for handling and assembly with no voltage. In case there is any failure or suspected failure in the device, it should be disconnected. You must install a circuit breaker protection to disconnect the equipment on the installation. Read all safety warnings. All safety and operating instructions should be read before using the machine. All warnings on the product and on the operating instructions should be strictly respected. Failure to follow the warnings and instructions listed below can cause electric shock , fire or serious injury, including risk of death. Water and moisture: This product should not be installed near any source of water, such as a faucet, shower, pool, kitchen, wet surface or alike, without using protective measures such as the adequate sealing protection index according to applicable regulations. Placement or installation of the appliance: The appliance must be installed on a stable and appropiate DIN rail or an equivalent fixing. Temperature: Do not exceed the storage temperature limits or operating temperature of the product. The product should be situated away from any heat sources such as radiators, stoves, heaters or direct sun light. Power supply: This product should be operated only with a compatible power supply. Please, read the table of features. Overloading: Do not overload the unit or its power supply as it may cause a product malfunction or its destruction. Object and Liquid Entry: Never access the device with any kind of object or pour any liquid as this may cause a short circuit and malfunction causing fire or electric shock . In case of failure: Do not attempt to service this product yourself opening or removing covers if you are not a qualified professional. Recycling: This product should not be treated the same way as domestic waste, instead you should take it to the nearest electronics recycling point. For more information about recycling this product, please contact your city waste service or the shop where you purchased the product. DECLARATION OF CONFIRMITY Declares under its own responsibility that thisproduct to which this declaration, meets the requirements of the following directives: 2004/108/EC on Electromagnetic Compatibility. 93/465/EC concerning the CE marking. 2011/65/EU regarding the restriction of use of hazardous substances RoHS. The device complies with the following standards: EN 60950-1 Daniel Lerch Hostalot EN 61000-6-1 EN 61000-6-3 El representante 3 © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Three-Phase installation for TE and TEW models As can be seen from the diagram, the installation consists of a ODEnergy T63E, T63EW, T200E or T200EW installed in a three-phase system. The equipment must be installed following a PIA magnetothermal protection. You must use the same model of power transformer for each of the 3 phases. L1 L2 L3 N Towards electrical installation measured Current transformes Ethernet network + - + L3 - + L2 Circuit Breaker - + L1 N WIFI Network Internet Register code / MAC address 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 The WIFI version also has an Ethernet port but you can only use one of the two ports at a time. N ODEnergy L1 L2 5 meters max L3 Terminals with current transformers + L3 + - + L2 - + L1 N Rj45 Ethernet Connector + L3 Bi-Color status LED Network link LED Register code / MAC address + L2 + - + L1 N Register code 0123456789AB Register at: cloud.opendomo.com Register code / MAC address Reset switch 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 N Terminals for power supply and voltage measurement Lines to monitor 4 You must connect one line corresponding voltage power line, if they do not correspond you will get erroneous measurements L3 L2 L1 N Neutral Ground © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Installation using transformers N / 5 (IEC 60044-1) As can be seen from the diagram, the installation consists of a ODEnergy TN5E or TN5EW installed in a three-phase system. The equipment must be installed following a magneto-thermal protection. You must use the same model of power transformer for 3 phases. L1 L2 L3 N Towards electrical installation measured Current transformer Current transformer N/5 type, for example 500/5 CTOD-5 Ethernet network + - + L3 - + L2 - + L1 N WIFI Network Circuit-breaker Internet Register code / MAC address 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 The WIFI version also has an Ethernet port, but you can only use one of the two ports at a time. N ODEnergy L1 L2 5 meters max L3 Terminals with current transformers + L3 + - + L2 - + L1 N Rj45 Ethernet Connector + L3 Bi-Color status LED Network link LED Register code / MAC address + L2 + - + L1 N Register code 0123456789AB Register at: cloud.opendomo.com Register code / MAC address Reset switch 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 N Terminals for power supply and voltage measurement Lines to monitor 5 You must connect one line corresponding voltage power line, if they do not correspond you will get erroneous measurements L3 L2 L1 N Neutral Ground © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Single-phase installation for ME and MEW models As can be seen from the diagram, the installation consists of a ODEnergy T63E, T63EW installed in a single phase system. The equipment must be installed following a magneto-thermal protection. The L1 phase is necessarily used. Towards electrical installation measured Current transformer Ethernet Network + - + L3 L2 + - + L1 N WIFI Network The WIFI version also has an Ethernet port, but you can only use one of the two ports at a time. Register code / MAC address Circuit-breaker 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 N L1 5 meters max Terminals with current transformers + L3 + - + L2 - + L1 N Rj45 Ethernet Connector + L3 Bi-Color status LED Network link LED Register code / MAC address + L2 + - + L1 N Register code 0123456789AB Register at: cloud.opendomo.com Register code / MAC address Reset switch 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 N Terminals for power supply and voltage measurement Lines to monitor 6 You must connect one line corresponding voltage power line, if they do not correspond you will get erroneous measurements L3 L2 L1 N Neutral Ground © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Single-phase installation of multiple sample points for TE and TEW models As can be seen on the diagram, the installation consists of a ODEnergy T63E or T63EW installed in a single phase system with 3 sample points, this way you can monitor up to 3 separate lines. The equipment must be installed following a magneto-thermal protection. The device is powered via terminal L1. All current transformers must be the same model. L1 N Ethernet Network + L3 + L2 + - + L1 - WIFI Network N Internet Register code / MAC address 0123456789AB Register at: cloud.opendomo.com Circuit-breaker L3 L2 L1 N The WIFI version also has an Ethernet port, but you can only use one of the two ports at a time. ODEnergy Current transformer Wall-plugs Circuit Lighting Circuit Heating Circuit L1 5 meters max Terminals with current transformers + L3 + - + L2 - + L1 N Rj45 Ethernet Connector + L3 Bi-Color status LED Network link LED Register code / MAC address + L2 + - + L1 N Register code 0123456789AB Register at: cloud.opendomo.com Register code / MAC address Reset switch 0123456789AB Register at: cloud.opendomo.com L3 L2 L1 N Terminals for power supply and voltage measurement Lines to monitor 7 You must connect one line corresponding voltage power line, if they do not correspond you will get erroneous measurements L3 L2 L1 N Neutral Ground © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 Installation Considerations regarding the Current Transformers N / 5 To maintain the best accuracy possible of a current transformer, you must consider the power dissipated in the circuit loop of the N/5 current transformer. Each meter of cable of the current transformer secondary circuit, it increases the power of current loop. In the technical characteristics of the transformer will find a table with the specification of the class I respect the power dissipated. To maintain a good accuracy class, you must not exceed the maximum power indicated by the transformer manufacturer. Do not use less than 1.5mm2 wire section. Example of data provided by a manufacturer of a transformer 500/5: IPN / ISN: 500 / 5A (primary current circuit / secondary current circuit) Class 1: 10 VA Class 0.5: 5 VA 0.2 Class: 2.5 VA The above data explains that the current transformer has an accuracy class 1 (± 1%) if the power loop is less than 10 VA, Class 0.5 (± 0.5%) if the power loop is less than 5 VA and Class 0.2 (± 0.2%) if the power loop is less than 2.5 VA. Continuing with data from the previous example, using a 1.5 mm2, not to be exceeded 8.3 meters to maintain class 0.2 as 2.5 VA / 0.3 = 8.3 m. The same example but with a cable 6 mm2 could reach 31.2 meters. Table of characteristics of the copper at 40 °C calculated for a current of 5A: Cable section VA/meter 2 0,3 2,5 mm 2 0,18 4 mm2 0,11 2 0,08 1,5 mm 6 mm Current loop 5A N L1 L2 0123456789AB Register at: cloud.opendomo.com + - L3 + L3 - + L2 53 mm L1 - 58 mm Register code / MAC address + N - Box dimensions 86 mm 8 © OpenDomo Services www.opendomo.com ODEnergy rev.19.1 2015 FAQ Reactive power has an incorrect value Verify that you have connected the current transformers to the ODEnergy properly. The current transformer connected to terminals L1 must correspond to the line connected to terminal L1, the current transformer connected to terminals L2 must correspond to the line connected to terminal L2 and so on. The active energy measurement, reactive and apparent is incorrect The transformation ratio might be misconfigured. Go to the device configuration page by accessing the device's IP address, for example: http://169.254.0.4, check the current transformer or the value of the transformation ratio is set to the correct value with the current transformers installed and modify these values if necessary. 9 © OpenDomo Services