Armacell Product Selection Guide Guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex® • The IAQ Insulation™ • Exclusive EPA-registered antimicrobial • Supports LEED initiatives advanced insulation 2 | Armacell Product Selector | www.armacell.us Product Selector Application REFRIGERATION, HOT & COLD LINES, CHILLED WATER HVAC Interior & exterior DUCT SYSTEMS MECHANICAL SYSTEMS, CHILLERS Product Requirements • • • • • • • Energy saving Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Low VOC, formaldehyde free • Fiber free • • • • • • • • • • • • • • • • • • • • • Recommended Product •A P Armaflex, AP Armaflex SS (Self-Seal) • Armaflex Coil • AP Armaflex W •A P Armaflex, AP Armaflex SS • AC Accoflex • Armaflex Coil Energy saving Code compliant 25/50 rating Tough, durable Flexible nergy saving E Code compliant Moisture resistant Mold resistant 25/50 rating Fiber free Noise blocking Outdoors: Maintenance-free, UV-resistant •A P Armaflex Self-Adhering (SA) Duct Liner/Wrap and AP Armaflex SA Sheet • AP Coilflex nergy saving E Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Sheet & roll forms Easy to cut and fabricate •A P Armaflex • AP Armaflex Sheet and Rolls Armacell Product Specs AP Armaflex FS Tubes, Sheet & Rolls AP Armaflex Tubes AP Armaflex Sheet, Rolls, Duct Liner/Wrap AP Coilflex Specifications Test Method Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) ASTM C 177 or C 518 0.28 (0.040) 0.286 (0.041) 0.25 (0.036) 0.256 (0.037) 0.25 (0.036) 0.256 (0.037) Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] ASTM E 96, Procedure A 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13] 0.05 [0.725 x 10 -13] (AP Armaflex) ASTM E 84 CAN ULC S-102 1-1/2" and 2" Thick 25/50 25/50 UL94 V-5VA 25/50 Microban Antimicrobial Protection — Yes Yes Yes Mold Growth Fungi Resistance Bacterial Resistance UL181 ASTM G21/C1338 ASTM G22 Meets Requirements Meets Requirements Meets Requirements Water Absorption, % by Volume ASTM C 209 0.2 0.2 0.2 Upper Use Limit — 220°F (105°C) 220°F (105°C) 180°F (82°C) Lower Use Limit ➀ — -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) Ozone Resistance ASTM C 1071 Excellent Good Good Ultraviolet (UV) Resistance QUV Chamber Test Excellent — — Third Party Certification Factory Mutual Approvals Flame Spread and Smoke Developed Index Yes Yes Yes GREENGUARD Certified IAQ Yes Yes Yes GREENGUARD Certified for Children and Schools Yes Yes Yes ➀ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. For applications of -40°F to -297°F (-40°C to -183°C) contact Armacell. Armacell Product Selector | www.armacell.us | 3 MECHANICAL SYSTEMS, CHILLERS INDUSTRIAL, PHARMACEUTICAL, MARINE & OFFSHORE SOLAR residential PLUMBING • • • • • • • • • • • • • • • • • • nergy saving E Code compliant Thermally efficient High temperature range for solar collectors • Mold resistant • Flexible • • • • • • • • UT Solaflex • Tubolit nergy saving E Code compliant Thermally efficient Moisture resistant Mold resistant 25/50 rating Sheet & roll forms Easy to cut and fabricate •A P Armaflex • AP Armaflex Sheet and Rolls nergy saving E Thermally efficient Moisture resistant 25/50 rating Flexible Durable, UV-resistant outdoors •A P Armaflex • Arma-Chek • NH Armaflex nergy saving E Economical Thermally efficient Moisture resistant 25/50 rating Fiber free Noise blocking AC Accoflex Tubes NH Armaflex UT Solaflex ArmaTuff Tubolit 0.27 (0.039) 0.226 (0.040) 0.27 (0.039) 0.276 (0.040) 0.28 (0.046) 0.286 (0.041) 0.25 (0.036) 0.256 (0.037) 0.00 [0.0 x 10 -13] 0.25 (0.036) 0.08 [1.16 x 10 -13] 0.05 [0.725 x 10 -13] 0.08 [1.16 x 10 -13] 0.05 [7.25 x 10 -13] 0.00 Laminate 25/50 30/200 Meets EB 4013, SOLAS,USN test. Toxicityfree* UL94 V-O 25/50 UL-94-V-0 (for exterior application) 25/50 No No No No No Meets Requirements Meets Requirements Meets Requirements Meets Requirements Meets Requirements 0.2 0.2 0.2 0.2 0.0 Laminate 0.2 220°F (105°C) 250°F (120°C) 300°F (150°C) 180°F (82°C) 200°F (93°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -297°F (-183°C) -200°F (-129°C) Good Excellent Excellent Excellent Good Excellent — Excellent Excellent — — Yes — Excellent — — Yes Yes — Yes — Yes Yes Yes Yes 4 | Armacell Product Selector | www.armacell.us AP Armaflex®, AP Armaflex® W and AP Armaflex® SS (Self-Seal) Pipe Insulation through 1” Wall Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: • Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F • Water Vapor Transmission: 0.05 perm-inch • Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application AP Armaflex, AP Armaflex W and AP Armaflex SS (Self-Seal) Pipe (Tube) Insulation is a black or white closed cell, fiber-free elastomeric foam and the world’s most recognized brand of flexible mechanical insulation. Self-seal version enables faster, labor saving installation. • Code Compliant: 25/50-rated through 1” wall. Acceptable for use in air plenums. • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. • Mold resistant: Made with EPA-registered Microban® antimicrobial product protection. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Retards heat gain and controls condensation drip from chilledwater and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping. • Acceptable for use in air plenums. 25/50-rated through 1” (25 mm). • Normally requires no supplemental vapor-retarder protection. • Armaflex insulation installs with Armaflex 520 Adhesive. However, Self-Seal (SS) saves labor and installed costs – only the butt joints require adhesive coating. • For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us. • Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. Specification Compliance • ASTM C 534, Type I — Tubular • ASTM G-22 Grade 1 • ASTM D 1056, 2B1 • ASTM E 84, NFPA 255, UL 723 • MIL-P-15280J, FORM T (Black) • CAN/ULC S102 • MIL-C-3133C (MIL STD 670B), • UL 94 5V-5A, V-O, File E 55798 Grade SBE 3* — Black only • NFPA 90A, 90B • MEA 96-85-M* • UL 181 • City of LA – RR 7642* • ASTM G-21/C1338, * Non-SS (Self-Seal) only • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications Values Test Method Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) 0.25 (0.036) 0.256 (0.037) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index 25/50* ASTM E 84 CAN/ULC S102 ➂ Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 220°F (-183°C)** — Lower Use Limit ➁ -297˚F (-183˚C)* — Ozone Resistance Good — Sizes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular 3/8”, 1/2”, 3/4”, 1”, (10, 13, 19 and 25mm) 3/8” ID to 8” ID* (10mm ID to 203mm) 6’ (1.8m) — Notes ➀O n the heating cycle, AP Armaflex SS Pipe Insulation withstand temperatures as high as 220°F (105°C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C). ➁A t temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. ➂A P Armaflex Black tested for CAN/ ULC. AP Armaflex White determined to be comparable. *F or applications of -40°F to -297°F (-40°C to -183°C), contact Armacell. Armacell Product Selector | www.armacell.us | 5 AP Armaflex® FS Pipe Insulation 1-1/2” and 2” (38 mm and 50 mm) Wall Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: • Thermal Conductivity: 0.28 BTU-in/hr. ft2 °F • Water Vapor Transmission: 0.08 perm-inch • Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application • Retards heat gain and controls condensation drip from chilledwater and refrigeration systems. Reduces heat flow for hot-water plumbing, liquid-heating and dual temperature piping. • Acceptable for use in air plenums. 25/50-rated through 2”. • Normally requires no supplemental vapor-retarder protection. • For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us. • Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. AP Armaflex FS Insulation is a black or white closed cell, fiber-free elastomeric foam, a code compliant 1-1/2” and 2” thick EPDM version of the world’s most recognized brand of mechanical insulation. • Code Compliant in greater thicknesses: 25/50-rated in 1-1/2” and 2” wall. Acceptable for use in air plenums. • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. • Mold resistant: Made with EPA-registered Microban® antimicrobial product protection. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. Specification Compliance • ASTM C 534, Type I and II — • ASTM G-21/C1338 Tubular Grade 1 • ASTM G-22 • ASTM C 1534 • ASTM D 1056, 2B1 • ASTM E 84, NFPA 255, UL 723 • MEA 96-85-M • UL 94 5VA, File E 55798 • City of LA – RR 7642 • NFPA 90A, 90B • UL 181 • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications Values Test Method Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) 0.28 (0.040) 0.256 (0.037) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A Flame Spread and Smoke 25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 220˚F (105˚C) Lower Use Limit ➁ -297˚F (-183˚C) ASTM C 534 Ozone Resistance Good — Sizes Tubes Wall Thickness (nominal) Form Inside Diameter Tubular Form Length 1-1/2” and 2” (38mm and 50mm) 3/8” to 6” IPS (10mm - 173mm) 6’ (1.8m) Notes ➀ On the heating cycle, AP Armaflex Pipe Insulation will withstand temperatures as high as 220°F (105°C). 520, 520 Black or 520 BLV Adhesive may be used with pipe insulation applications up to 220°F (105°C). ➁At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell. 6 | Armacell Product Selector | www.armacell.us AP Armaflex® Sheet & Roll Insulation and AP Armaflex® SA Self-Adhering Sheet & Roll Insulation Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: • Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F • Water Vapor Transmission: 0.05 perm-inch • Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application • Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems. • Acceptable for use in air plenums. 25/50-rated through 1” (25 mm). • Normally requires no supplemental vapor-retarder protection. • Armaflex insulation installs with Armaflex 520 Adhesive. However, Self-Adhering (SA) saves labor and installed costs – only the joints require adhesive coating. • For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us. • Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. AP Armaflex and AP Armaflex SA Self-Adhering Sheet & Roll Insulation is a black closed cell, fiber-free elastomeric foam and the world’s most recognized brand of flexible mechanical insulation. Selfadhering version enables faster, labor saving installation. • Code Compliant: 25/50-rated through 1” wall. Acceptable for use in air plenums. • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. • Mold resistant: Made with EPA-registered Microban® antimicrobial product protection. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. Specification Compliance • ASTM C 534, Type II — • ASTM G-21/C1338, Sheet Grade 1 • ASTM G-22 • ASTM C 1534 • ASTM D 1056, 2B1 • ASTM E 84, NFPA 255, UL 723 • MIL-P-15280J, FORM S • CAN/ULC S102 (25 mm) • MIL-C-3133C (MIL STD 670B), • UL 94 5V-5A, V-O, File E 55798 Grade SBE 3 • NFPA 90A, 90B • MEA 107-89M • UL 181 • City of LA – RR 7642 Values Test Method Notes ➀When AP Armaflex Sheet is installed Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C) 90°F Mean Temperature (32°C) 0.25 (0.036) 0.256 (0.037) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 1” (25mm)* 25/50 ASTM E 84 CAN/ULC S102 Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit ➀ 180/220°F (82/105°C) — Lower Use Limit ➁ -297°F (-183°C)** — ➂Reference only. by adhering butt joints and seams only, the upper temperature limit is 220°F (105°C) using 520, 520 black, or 520 BLV Adhesive. AP Armaflex Sheet adhered with complete adhesive coverage on flat or curved metal surfaces may be applied to surfaces that will operate as high as 180°F (82°C) using 520, 520 Black, 520 BLV or Armaflex Low VOC Spray Contact Adhesive. ➁ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. Ozone Resistance Good — Sizes: Sheet Width Thickness (nominal) x Length 36” x 48” (.915m x1.22m) 1/8”, 1/4”, 3/8”, 1/2”, 3/4”, 1”, 1-1/2” & 2” (3, 6, 10, 13, 19, 25, 38 & 50mm) * For 25/50 above 1” (25mm), Please see AP Armaflex FS submittal. 1-1/2” and 2” available in 25/50 and non 25/50. — ** For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell. Sizes: Roll Width Thickness (nominal) x Length 48” (1.22mm) 60” (1.53m) in 1” thickness only 3/8” x 100’ (10mm x 30.5m) 1/2” x 70’ (13mm x 21.4m) 3/4” x 50’ (19mm x 15.2m) 1” x 35’ (25mm x 10.7m) 1-1/2” x 25’ (38mm x 7.6m) 2” x 18’ (50mm x 5.4m) — Armacell Product Selector | www.armacell.us | 7 AP Armaflex® FS Sheet & Roll Insulation 1-1/2” and 2” (38 mm and 50 mm) Thickness Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: • Thermal Conductivity: .28 BTU-in/hr. ft2 °F • Water Vapor Transmission: 0.08 perm-in • Fire Rating: 25/50 through 2” thickness Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application • Retards heat gain and controls condensation drip from chilled-water and refrigeration systems. Reduces heat flow on hot systems. • Acceptable for use in air plenums. 25/50-rated through 2” (50 mm). • Normally requires no supplemental vapor-retarder protection. • Armaflex insulation installs with Armaflex 520 Adhesive. • For below ground applications, contact Armacell or see Technical Bulletin No. 7 on our website, www.armacell.us. • Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. AP Armaflex FS Sheet & Roll Insulation is a black closed cell, fiberfree elastomeric foam, a code compliant 1-1/2” and 2” thick EPDM version of the world’s most recognized brand of mechanical insulation. • Code Compliant in greater thicknesses: 25/50-rated in 1-1/2” and 2”. Acceptable for use in air plenums. • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. • Mold resistant: Made with EPA-registered Microban® antimicrobial product protection. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value rated R-8 at 2” thickness. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications Values Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. Specification Compliance • ASTM C 534, Type II — Sheet • ASTM G-21/C1338, Grade 1 • ASTM G-22 • ASTM C 1534 • ASTM D 1056, 2B1 • ASTM E 84, NFPA 255, UL 723 • MEA 96-85M • UL 94 5VA, File E 55798 • City of LA – RR 7642 • NFPA 90A, 90B • UL 181 Test Method Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 0.28 (0.040) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A Flame Spread and Smoke Developed Index through 2” (50mm) 25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit 180˚F (82˚C) — Lower Use Limit ➀ -297˚F (-183˚C) — Ozone Resistance Good — Sizes: Sheet Width Thickness (nominal) x Length 36” x 48” (.915m x 1.22m) 1-1/2” and 2” (38 and 50mm) — Sizes: Roll Width Thickness (nominal) x Length Notes ➀At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency and resistance to water vapor permeability of Armaflex insulation. ➁ Reference Only 48” (1.22mm) and 60” (1.53m)† 1-1/2” x 25’ (38mm x 7.6m) 2” x 18’ (50mm x 5.4m) — * For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell. 8 | Armacell Product Selector | www.armacell.us AP Armaflex® SA and AP Armaflex® FS Duct Liner Factory Mutual (FM) Approvals AP Armaflex is approved through continuing supervision by Factory Mutual Approvals: • Thermal Conductivity: AP Armaflex: 0.25, AP Armaflex FS 0.08 BTU-in/hr. ft2 °F • Water Vapor Transmission: AP Armaflex: 0.05, AP Armaflex FS 0.08 perm-in • Fire Rating: 25/50 through 2” thickness ➀ Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application AP Armaflex SA (Self-Adhering) and AP Armaflex FS Black Duct Liners are patented*, non-fibrous duct liner with an advanced pressure sensitive adhesive system for non-pinned applications. They can also be applied as a duct wrap to existing duct work. Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. • Code Compliant in greater thicknesses: 25/50-rated through 2”. Acceptable for use in air plenums. • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. • Mold resistant: Made with EPA-registered Microban® antimicrobial product protection. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Self-Adhering (SA) system saves labor and installed costs – only the joints require adhesive coating. Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) Specification Compliance • ASTM C 534, Type II — Sheet • ASTM G-21/C1338, Grade 1 • ASTM G-22 • ASTM C 1534 • ASTM D 1056, 2B1 • ASTM E 84, NFPA 255, UL 723 • MIL-P-15280J, FORM S • CAN/ULC S102 (25 mm) • MIL-C-3133C (MIL STD 670B), • UL 94 5VA, File E 55798 Grade SBE 3 • NFPA 90A, 90B • MEA 107-89M • UL 181 • City of LA – RR 7642 US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications • Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain. • Excellent for reducing HVAC noise, especially in low frequency ranges. Performance peaks at 500 Hz, a critical frequency in a duct system. • Application areas include schools, hospitals, hotels, commercial and public buildings. • Acceptable for use in air plenums. AP Armaflex SA 25/50-rated through 1” (25 mm). Where 25/50-rated R-6 or R-8 is required, select AP Armaflex FS in 1-1/2” or 2” thicknesses. Values Test Method AP Armaflex AP Armaflex FS 0.25 (0.036) 0.256 (0.037) 0.28 (0.040) 0.286 (0.041) Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] 0.08 [1.16 x 10-13] Flame Spread and Smoke Developed Index ➀ Through 1” (25 mm) 25/50 1-1/2” and 2” 25/50 Mold Growth Fungi Resistance Bacterial Resistance Water Absorption, % by Volume Upper Use Limit ➁ Meets requirements 0.2% ASTM C 177 or C 518 ASTM E 96, Procedure A ASTM E 84 CAN ULC S-102 – AP through 1” UL181 ASTM G21/C1338 ASTM G22 ASTM C 209 180˚F (82˚C) Lower Use Limit ➂ -297˚F (-183˚C) Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Noncorrosive ASTM C 665 No objectionable odors ASTM C 665 Corrosiveness Odor Emissions Notes ➀ AP Armaflex SA Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1” (25 mm) when tested according to ASTM E 84 and CAN ULC S-102. AP Armaflex FS has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1-1/2” and 2” when tested according to ASTM E 84 and CAN ULC S-102. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁Withstands temperature of 250°F (121°C) when tested according to ASTM C 411. “Test Method for Surface Performance of High-Temperature Insulations”. At this temperature, AP/ Armaflex SA Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180°F (82°C). ➂At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. Armacell Product Selector | www.armacell.us | 9 Sound Absorption Coefficients at Frequency Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC† Nom. 1” (25 mm) 0.01 0.13 0.39 0.69 0.29 0.26 0.40 † ASTM C 423 with ASTM E 795 Type “A” Mounting Sound Transmission Class (STC) Thickness STC Class Nom. 1/2” (13 mm) 25 Nom. 1” (25 mm) 25 Sizes Sheet Width / Length 36” x 48” Roll Width 48” (all thicknesses) and 60” (1” only) Wall Thickness AP Armaflex: 3/8”, 1/2”, 3/4” and 1” AP Armaflex FS: 1-1/2” and 2” AP Armaflex SA and AP Armaflex FS Black Duct Liners / Wraps Patented* for Air Systems that Require an Alternative Duct Liner / Wrap Features Benefits Advanced, aggressive PSA No pinning required, faster installation Closed cell structure Resists moisture, nonwicking Reduced water presence in system and insulation Noise blocking Nondusting Longer life Won’t contribute to air quality problems Made with Microban antimicrobial product protection Resists mold on the insulation EPA registered for use in air duct insulation Smooth surface that reduces dirt and debris accumulation Inhibits amplification of biological contaminants Basis for continuing system hygiene Elastomeric material Fiber free Resistant to incidental damage No special tools; no dust mask required during fabrication and installation Inherent vapor retarder Requires no mastics Competitive total installed cost * US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning. 10 | Armacell Product Selector | www.armacell.us AP Coilflex® Conformable Duct Liner Ratings • Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F • Fire Rating: will not contribute significantly to fire (simulated end-use testing) Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application • Ideal for air handling systems, VAV units, ducts and other air system components requiring condensation control, or resistance to moisture, damage or heat gain. • Excellent for reducing HVAC noise, especially in low frequency ranges. Performance is twice as effective as fiberglass at 500 Hz, a critical frequency in a duct system. • Application areas include schools, hospitals, commercial buildings. • Acceptable for use in air plenums. 25/50-rated through 1” (25 mm). AP Coilflex Duct Liner is a patent-pending*, cost-effective, and highly conformable non-fibrous acoustic duct liner created for automated applications with water-based adhesives in accordance with SMACNA pinning and spacing guidelines, or unpinned applications using an Armaflex 520 Adhesive. It can also be applied as a duct wrap to existing duct work. • Normally requires no supplemental vapor-retarder protection. • Practical and Cost Saving: Easily conforms to fabricated duct corners without stiffness or bulging and compression; requires fewer cuts and expensive encapsulation or inner wall. • Exceptional Acoustic Performance: Superior sound absorption at low frequencies critical top speech intelligibility. • Mold resistant: Made with EPA-registered Microban® antimicrobial. • Energy efficient: Contributes toward LEED Certification, meets the energy code requirements of ASHRAE 90.1, International Energy Conservation Code (IECC) and other building codes. R-Value of 4.2. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specification Compliance • ASTM C 534, Type II — Sheet • NFPA 90A, 90B Grade 1 • UL 181 • ASTM C 1534 • ASTM G-21/C1338, • ASTM E 84, NFPA 255, UL 723 • ASTM G-22 • CAN/ULC S102 (25 mm) • ASTM D 1056, 2B1 • UL 94 5VA, File E 55798 Specifications Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. *US Patent 5971034 – “Thermal Duct Lining Insulation” for lining variable air volume boxes, air handling units, and ducts for heat ventilation and air conditioning Values Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C) Flame Spread and Smoke Developed Index ➀ Through 1” (25 mm) Test Method 0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518 25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Upper Use Limit ➁ 180˚F (82˚C) — Lower Use Limit ➂ -297˚F (-183˚C) — Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071 Corrosiveness Noncorrosive ASTM C 665 Odor Emissions No objectionable odors ASTM C 665 Sound Absorption Coefficients at Frequency Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC† Nom. 1” (25mm) 0.08 0.22 1.03 0.37 0.68 0.50 0.60 Sound Transmission Class (STC) Thickness STC Class Nom. 1/2” (13 mm) 25 Nom. 1” (25mm) 25 Sizes Roll Width 46”, 47”, 48” , 56-1/4”, 59” and 60” Wall Thickness 1” 1/2” (special order) Notes ➀ AP Coilflex Duct Liner has a flame spread index of less than 25 and a smoke developed index of less than 50 for all thicknesses up to and including 1” (25 mm) when tested according to ASTM E 84. Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. ➁ Withstands temperature of 250°F (121°C) when tested according to ASTM C 411. “Test Method for Surface Performance of High-Temperature Insulations”. At this temperature, AP Coilflex Duct Liner insulation shows no evidence of flaming, glowing, smoldering, delamination, melting or insulation collapse. Although this insulation will withstand high temperatures, continuous use temperature should be limited to 180°F (82°C). ➂ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency of Coilflex insulation. † ASTM C 423 with ASTM E 795 Type “A” Mounting Armacell Product Selector | www.armacell.us | 11 NH Armaflex® Pipe, Sheet & Roll Insulation and NH Armaflex SA Roll Insulation Uses & Application • Closed-cell material that eliminates toxic gases that may threaten personnel and sensitive electronic equipment including effects from chlorines, bromines and PVC. • Used as insulation and protection for piping, tanks, and air ducts, and to prevent stress corrosion with stainless steel pipes in the following applications: • US Navy applications • General shipbuilding • IMO (International Maritime Organization) • Nuclear power plants • Other areas where nonhalogenated or chlorine-free materials may be required Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. NH Armaflex Insulation is a nonhalogen elastomeric insulation developed for sweat control in environments that require specific protection against smoke containing acid gases. It is also available selfadhering (SA) in roll form. • Innovative: The first nonhalogen flexible insulation introduced for shipboard use. • Safety first: Fire tested at the Naval Research Laboratory (NRL) in controlled comparisons with baseline materials. Further testing through DDG-51 and NSSN produced references that NH Armaflex scored better than MIL-P-15280J materials such as AP Armaflex. Specification Compliance • Electric Boat Corporation • NH Armaflex is currently Specification EB 4013 Antisweat specified for use on US Navy and Refrigerant Insulation vessels Systems (Sheets and Tubes) • UL-V-O and HF-1 File Number • International Maritime E55798 Organization (IMO) SOLAS • ASTM C534 Type 1 (Tubular) Requirements Grade 3, Type II (Sheet) Grade 3 • United States Coast Guard • ASTM C795 Requirements* • Nuclear Regulatory Commission Regulatory Guide 1.36 Thickness Nominal Sizes • Moisture resistant: Closed cell structure prevents condensation and wicking, no supplemental vapor retarder required. 1/2” (13 mm) 3/4” (19 mm) 1” (25 mm) Available in nominal pipe sizes from 3/8” to 8” (1” thickness special order) 1-1/2” (38 mm) Not Available • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, nonparticulating. SA (Self-adhering) is the reduced VOC version. Tube 6’ (1.8 m) in length • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Sheet 3’ x 4’ (0.915 m X 1.22 m) Available Roll 4’ (1.22 m) width 70’ (21.4 m) 50’ (15.2 m) 35’ (10.7 m) 25’ (7.6 m) length length length length *Available special order only. Specifications Values Test Method Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 32°F mean temperature (0°C) 75°F mean temperature (24°C) 104°F mean temperature (40°C) 0.248 (0.036) 0.27 (0.039) 0.282 (0.041) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% ASTM C 209 Upper Use Limit 250˚F (120˚C) — Lower Use Limit ➀ -297˚F (-183˚C) ASTM C 534 Ozone Resistance Excellent ASTM D 1149 Toxicity Free from Halogen/Dioxin/CFC/Mercury/Carbon Black/Heavy Metal — IMO (International Organization) Combustion Gas Concentration (Pass) Smoke Density (Pass) Heat Release Rate (Pass) Flame Spread (Pass) Navy Large Marinetime Scale Pipe Insulation Room/ Corner Test Behavior in Fire Does not support progressive flaming, will not melt or drip. Meets EB 4013 Meets IMO SOLAS requirements — Notes ➀ At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of Armaflex insulation. Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. 12 | Armacell Product Selector | www.armacell.us UT Solaflex™ Pipe Insulation Uses & Application • Closed-cell structure provides low thermal conductivity, excellent fire and smoke behavior, low temperature flexibility and excellent protection against water vapor diffusion. • No painting is necessary for performance of the product. (However, all elastomeric-based cellular insulation will show surface defects after prolonged exposure to UV radiation. Painting will minimize these defects.) • Performs on a broad range of metal pipes and tubing in piping and collectors, refrigeration-hot gas and dual temperature piping, automotive (under hood) and low pressure steam lines. • Oil-resistant as tested by ASTM Oil No. 1 and No. 3. Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. UT Solaflex Tube and Roll Insulation is a UL-listed closed cell, fiberfree, 25/50-rated flexible EPDM elastomeric foam insulation for high temperature, UV-resistant and oil-resistant applications. Specification Compliance • ASTM C 534, Type I — • Tubular Grade 2, Type II (Sheet), Grade 2 • UL 94 UL 94 5VA, V-P, File E 55798 • Innovative: New generation of insulation for solar collectors, refrigeration (including hot gas piping) and automotive. • High temperature: Remains flexible at temperatures up to +300°F (+150°C), with intermittent exposure to +350°F (+175°C). • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOC, resists mold. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Durable: No fragile vapor retarder and lasts the life of the mechanical system. Specifications Values Test Method Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 0.28 (0.040) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.08 [1.16 x 10-13] ASTM E 96, Procedure A 25/50 ASTM E 84 Flame Spread and Smoke Developed Index through 1” (25mm) Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 UV Weather Resistance Excellent QUV Chamber Test ASTM G90 (EMMAQUA) Upper Use Limit ➀ 300˚F (150˚C) — Lower Use Limit ➁ -297˚F (-183˚C) — Ozone Resistance Excellent ASTM D 1149 Sizes: Tubes Wall thickness, (nominal) Inside diameter, tubular Length of sections, tubular 1/2”, 3/4”, 1” (13, 19, 25mm) 1/2” through 2-1/2” IPS (13mm to 63.5mm) 6’ (1.8m) Sizes: Rolls Width Thickness x Length 48” (1.2m) 1/2” x 70’ (13mm x 21.3m) 3/4” x 50’ (19mm) x 15.2 m) 1” x 35’ (25mm x 10.7m) — — Notes ➀Suitable for systems with occasional or intermittent temperatures to 350°F (175°C), with a recommended exposure limit of one 30 minute period at 350°F (175°C) over 24 hours of operation. ➁At temperatures below -20°F (-29°C), elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of UT Solaflex insulation. Armacell Product Selector | www.armacell.us | 13 ArmaTuff® Laminated Sheets and Rolls Uses and Applications ArmaTuff is designed to be used for all exterior applications: Exterior ducts, tanks, vessels, large pipes and fittings. The laminate is resistant to UV, ozone, acid rain and most industrial pollutants. No painting is required. Application ArmaTuff is installed using Armaflex Adhesives or with pre-applied pressure sensitive adhesive (PSA) for application to large, flat or curved metal surfaces such as ducts, vessels, very large pipes or tanks. The seams must be installed in compression and sealed with Armaflex Adhesives. Cover the seam with ArmaTuff Seal Tape. Armaflex 520 Adhesive is a contact adhesive: therefore it must be applied to both surfaces, allowed to get tacky, and the surfaces joined with pressure. Exterior duct work must be pitched to allow rain water to run off the insulation. ArmaTuff is the premiere Armacell Coating System for outdoor applications. It provides a tough metal surface on Armaflex insulation for superior protection against ultraviolet radiation and punctures. • • • • Maintenance-free: UV- and damage resistant 10 mil laminate Long-lasting protection: 10-year membrane limited warranty Flexible application: Available with or without PSA Color: White Description ArmaTuff is designed for installation in above ground applications. Armaflex insulation products must be installed according to Installation of Armaflex Insulations brochure. Proper installation is required to assure Armaflex insulation performance. The application temperature should be above 40°F (+4°C) and 100°F (+38°C). Finishing the Installation with ArmaTuff Seal Tape ArmaTuff is a complete insulation system providing durable, UVresistant and maintenance-free outdoor performance. Tape is backed with pressure sensitive adhesive and designed to provide protection along the seams and exposed edges of the insulation. Tape is supplied in rolls 6”-wide for sealing seams and exposed edges of ArmaTuff. ArmaTuff is Armaflex insulation with a 12 mil laminated covering membrane. The membrane has a 10-year limited warranty against break-down due to UV radiation. Armaflex is a mold-resistant flexible elastomeric thermal insulation. Its closed-cell structure prevents condensation and moisture wicking, and makes it an efficient insulation. It is manufactured without the use of CFCs, HFCs or HCFCs. It is available in 36” x 48” sheets (with or without pressure sensitive adhesive) and in rolls 48” wide (without PSA), in 1”, 1-1/2”, 2” thicknesses. Specifications Values Test Method Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F Mean Temperature (24°C) 90°F Mean Temperature (32°C) 0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518 Water Vapor Permeability, Perm-in. [Kg/(s•m•Pa)] Laminate 0.00 Foam 0.05 ASTM E 96, Procedure A Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Water Absorption, % by Volume 0.2% / 0.0% laminate ASTM C 209 Upper Use Limit 180°F (82°C) — Lower Use Limit ➀ -297°F (-183°C)* — UltraViolet (UV) Resistance Excellent ASTM G 90 QUV Chamber Chemical Resistance Excellent — Weatherability Excellent ASTM D471 Durability Excellent — Sizes: Sheet – With or Without Adhesive Width and Length Thickness (nominal) 36” x 48” (0.915 m x 1.22 m) 1”, 1-1/2” and 2” (25, 38 and 50 mm) — Sizes: Roll – Without Adhesive Width Thickness (nominal) x Length 48” (1.22 m) 1” x 35’ (25 mm x 10.7 m) 1-1/2” x 25’ (38 mm x 7.6 m) 2” x 18’ (50 mm x 5.4 m) — Notes ➀ At temperatures below -20°F (-29°C) elastomeric insulation starts to become less flexible. However, this characteristic does not affect thermal efficiency or water vapor permeability of ArmaTuff. ➁ Reference only. * For applications of -40°F to -297°F (-40°C to -183°C), contact Armacell. 14 | Armacell Product Selector | www.armacell.us Tubolit® Pipe Insulation, Tubolit® SS Self Seal, Tubolit® White SS, Tubolit® W Tape Ratings • Thermal Conductivity: 0.25 BTU-in/hr. ft2 °F • Water Vapor Transmission: 0.00 perm-inch • Fire Rating: 25/50 Note: Numerical flammability ratings alone may not define the performance of products under actual fire conditions. They are provided only for use in the selection of products to meet limits specified. Uses & Application • Reduces heat loss on hot water plumbing and heat gain on coldwater plumbing systems. • Recommended for use on lines operating from -200°F (-129°C) to 200°F (93°C). • Normally requires no supplemental vapor-retarder protection. • Tubolit insulation installs with Armaflex 520 Adhesive. However, Self-Seal (SS) products save labor and installed costs – only the butt joints require adhesive coating. • Outdoors, a weather-resistant protective finish is to be applied. Armaflex WB Finish is recommended. Tubolit Pipe (Tube) Insulation is an economical thermal solution from Armacell, the makers of Armaflex® and the world’s leading supplier of tubular polyethylene insulation. Self-seal versions enable faster, labor saving installation. • Proven: Used worldwide for insulating domestic hot and cold plumbing lines. • Economical: Cost-saving polyethylene. Tubolit White SS is a costcompetitive fiber-free 6’ alternative to 3’ fiberglass. The associated Tubolit W Tape is compatible with standard fitting covers. • Energy efficient: Reduces heat loss and gain. • Moisture resistant: Closed cell structure prevents condensation and wicking; no supplemental vapor retarder required. • Indoor Air Quality-friendly: Fiber-free, formaldehyde-free, low VOCs. Meets stringent GREENGUARD Indoor Air Quality Certification for Children & Schools. • Quiet: Reduces plumbing noise. • Resists Mold and Mildew Specifications Armaflex insulation products must be installed according to “Installation of Armaflex Insulations” brochure. Specification Compliance • ASTM C 1427, Type I • MEA 6-02M Values Test Method Notes ➀Average values are not to be used Thermal Conductivity, BTU • in./h • ft2 • °F (W/mK) 75°F (24°C) mean temperature 0.25 (0.036) ASTM C 177 or ASTM C 518 Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.0 ASTM E 96, Procedure A Flame Spread and Smoke D eveloped Index through 1” (25 mm) Thickness ➁ 25/50 ASTM E 84 Mold Growth Fungi Resistance Bacterial Resistance Meets requirements UL181 ASTM G21/C1338 ASTM G22 Upper Use Limit ➀ 180°F (-129°C) — Lower Use Limit ➁ -200˚F (-129˚C) — Ozone Resistance Good — Sizes Wall Thickness (nominal) Inside Diameter, Tubular Length of Sections, Tubular Tape 3/8”, 1/2”, 3/4” and 1” (10, 13, 19 and 25 mm) 3/8” to 4” IPS ID (10 mm to 114 mm ID) 6” (1.83 m) 2” wide x 60’ — for writing material specifications. Contact Armacell for specification ranges. ➁Cellular plastics and thermoplastics, such as polyethylene/polyolefin insulation, that may drip, melt, delaminate or draw away from the fire, present unique problems and require careful interpretation of the test results. ➂For reference only. Armacell Product Selector | www.armacell.us | 15 Insulation Products for Mechanical Systems Armaflex Adhesives Armaflex WB Finish Armaflex® 520 and Armaflex 520 Black Adhesives are air-drying contact adhesives that are excellent for joining seams and butt joints of AP and NH Armaflex Pipe and Sheet Insulation and Tubolit Pipe Insulation. Where a low V.O.C. adhesive is required, use Armaflex 520 BLV Adhesive. Armaflex WB Finish is a white water-based latex enamel for use over all forms of Armaflex insulations. It provides a protective semi-gloss finish for both indoor and outdoor applications. Armaflex WB Finish brushes or rolls on easily. Its water base formulation makes it fastdrying without solvent fumes. Cleans up with soap and warm water. Armaflex WB Finish is supplied in gallon and quart containers. ® 520 Adhesives meet MIL-A-24179A and Amend-2 as Type II, Class 1. 520 Adhesives when dried to a film meet codes and specifications of less than 25 for flame spread and less than 50 for smoke (ASTM E 84). Armaflex Low VOC Spray Contact Adhesive, green in color, is supplied in 27 pound aerosolized canisters. The product contains no chlorinated solvents such as methylene chloride and does not contain ozone depleting compounds. Complies with SCAQMD rule 1168 for volatile organic compound content less than <5 g/l. Dried film meets the fire building codes of flame spread index of less than 25 and smoke developed index of less than 50. Excellent for bonding Armaflex sheet and roll insulations to vessels, tanks, ducts and mechanical equipment operating at temperatures below 180°F (82°C). ® Impervious to moisture. Outdoors, is exceptionally durable and weather resistant to ultraviolet (UV) and ozone. Outdoor surfaces should be recoated every 2-4 years. Armacell Fabricated Fittings Armacell Fabricated Fittings are madeto-order and prefabricated using the world’s highest quality, closed cell insulation. Available in wall thicknesses up to 2”, these fittings are labor saving, easy to work with and apply, and provide total Armaflex system integrity. Options include 90-degree elbows (2-piece and 3-piece), T’s, 45-degree elbows, grooved fittings (AP Armaflex black) and grooved couplings Insulation Tape Armafix IPH, NPH Pipe Hangers Armafix is used to support Armaflex and Armaflex NH (nonhaogen)insulated pipes with pre-insulated hangers that retard heat gain and control condensation drip from chilledwater and refrigeration systems. See Armafix Submittal Sheet for details. AP Armaflex® Insulation Tape is made of high-quality AP Armaflex insulation. Available in tape dispenser form, the expanded closedcell structure makes it an efficient insulation. Made with Microban® antimicrobial product protection, our tape is also formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew. Provides a fast, easy method for insulating pipes and fittings. Reduces heat loss when applied to hot-water lines that operate up to 180°F (82°C). AP Armaflex Tape may be used with AP Armaflex Pipe and Sheet Insulation. The Armacell Advantage Building Relationships That Endure World Leader in Mechanical Insulation Armacell is an easyaccess organization that values customers as business partners. Support is available for help with installation, clarifying technical and code compliance issues, and specification assistance. Armacell is the global leader in mechanical insulation and foam technologies. Armacell developed Armaflex, the world’s first elastomeric thermal insulation and continues to provide product solutions to meet the challenges of thermal efficiency, condensation control, indoor air quality, sound attenuation and long-lasting performance. Armacell has unrivaled global capabilities bolstered by 20 manufacturing facilities in 13 countries. Globally integrated research and development allows our scientists and technicians to benchmark global practices and adapt them to either global or regional requirements, codes or specifications. • Customer Service: The Armacell Customer Service Team has earned a reputation as the best in our industry. Teams from manufacturing, logistics and customer service meet daily to anticipate surges in demand, monitor service levels, and promptly resolve any customer inconveniences. • Application Assistance: Guidance and training for installers, from the experts who trained an industry. • Technical Assistance: Expertise to help solve application problems and clarify technical and code compliance issues. •Specification Assistance: Expertise in helping with specifications and providing the right solutions for the most demanding specification criteria. Call 800-866-5638 8:00 a.m. – 4:30 p.m. EST M-F for assistance. ARMACELL LLC 7600 Oakwood Street Extension Mebane, NC 27302 TEL: 1 800 866-5638 FAX: 919 304-3847 E-MAIL: info.us@armacell.com INTERNET: www.armacell.us advanced insulation 04 11 NA NA © 2011 Armacell LLC Printed in United States of America MICROBAN is a registered trademark of Microban Products Company. The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute.