GE Digital Energy Power Quality Introduction I It is a fact that transient voltage surges from both external and internal sources directly affect the performance and life expectancy of electronic equipment. From electronic lighting ballasts to computer servers, if there is a printed circuit board inside, it is susceptible to transient voltage surge damage. As microprocessors and components that make up this equipment grow smaller and faster with each new generation, their susceptibility to transient voltage surge damage becomes ever greater. Available in ratings from 65kA - 300kA per mode, (130kA 600kA per phase) the TR7000 series is the perfect surge suppression product for protecting critical sensitive electronic equipment throughout your facility. The full-featured TR7000 series with its advanced monitoring, disconnect and enclosure options has been designed to handle the highest levels of surge activity found in the most demanding commercial and industrial facilities. These units are ideal for both new and retrofit applications where performance cannot be compromised. Wallmount TR7000 Series Surge Protective Device (SPD) Recommended installation locations are service entrance and primary and secondary distribution. The TR7000 Series has been third-party tested to ANSI/IEEE C3 (10kA, 8x20μs) service entrance level transient surges including all components. The entire TR7000 line up has been engineered to the highest standards and is designed for rigorous duty and long life as evidenced in our outstanding minimum repetitive surge current capacity test results. Features and Benefits Applications > The TR7000 provides maximum surge protection with outstanding clamping characteristics for ultra high, high, medium and low exposure locations with the use of industrial-grade MOV architecture. > Third-party tested per IEEE C62.62 and NEMA LS-1 for the rated 8x20μs surge current, per mode with fusing included. > Fast rise-times, high frequency transients and electrical line noise are reduced with standard EMI / RFI filtering technology. > Maximum installation flexibility is achieved in the TR7000 through its high surge suppression kA to small footprint ratio. > 10 modes of protection (L-N, L-G, N-G, L-L) > Service Entrance > Distribution Equipment > Green phase status LEDs with Red alarm LED > NO/NC Form C Dry Contacts for remote monitoring > Industrial sized MOV technology > Thermal fuse technology combined with 200kAIC surge rated fuses > Audible alarm with push-to-test switch, enable/disable function > Surge counter > Optional 200kA surge rated disconnect > NEMA 1, 12, 4 and 4X enclosures available > Surface and flushmount-style enclosures > 5 year limited warranty (standard), 10 year limited warranty (optional) > Branch Panel > New Construction and Retrofits > System Expansions Standards > > > > > > > > > UL 1449 3rd Edition, Type 2 UL 1283, EMI/RFI noise filter UL 96A, Lightning Protection System cUL, CSA C22.2 ANSI/IEEE C62.41 - ANSI/IEEE C62.45 IEEE C62.62 NEMA LS-1 - 1992 (R2000) MIL-STD-220B ANSI/NFPA 70 (Article 285) Technical Specifications Nominal Discharge Current (In) 20kA Short Circuit Current Rating (SCCR) 200kA (60A breaker required) Operating Frequency 50/60 Hz Connection Minimum Repetitive Surge Current Capacity 6 to 2/0 AWG Lugs, Parallel Connected (Per ANSI/IEEE C62.62) Operating Temperature The TR7000 Series is capable of surviving the following impulses, at one-minute intervals, without failure and with less than 10% change in protective characteristics. > 20,000 Category C3 impulses 20kV/10kA, 8x20μs for 120-300kA rated devices > 5,000 Category C3 impulses 20kV/10kA, 8x20μs for 65-100kA rated devices > 5,000 500V/2kA, 10x1000μs long wave impulses for all TR7000 devices DEA-365 • Page 2 -40° F to 149° F (-40° C to +65° C) Operating Humidity 0% to 95% Non-Condensing Weight WMN1D 55 lbs. (25 kg) WMN12S, 12F, 4S, 4D 37 lbs. (17 kg) WMN4X 40 lbs. (18 kg) R7 MCOV Nominal Voltage (Volts RMS) System Voltage Configuration (50/60 Hz) Max. Continuous Operating Voltage 120S 120/240 1 Ph, 3 W + G 150V 120Y 120Y/208 3 Ph, 4 W + G 150V Maximum Surge Current Capacity Per Mode Per Phase Suffix Enclosure Description NEMA 065 65kA 130kA 1D Painted Steel 1 Surface Yes 080 80kA 160kA 12S Painted Steel 12 Surface No Flush No Surface Yes 220Y 220Y/380 3 Ph, 4 W + G 320V 100 100kA 200kA 12F Painted Steel 12 240D 240 Delta 3 Ph, 3 W 270V 125 125kA 250kA 4D 240H 120/240 Delta HL 150 150kA 300kA 240Y 240Y/415 3 Ph, 4 W + G 320V 200 200kA 400kA 277Y 277Y/480 3 Ph, 4 W + G 320V 250 250kA 500kA 347Y 347Y/600 3 Ph, 4 W + G 420V 300 300kA 600kA 480D 480 Delta 3 Ph, 3 W 550V 3 Ph, 4 W + G See Note * Mounting Disconnect Fiberglass 4X 4S Painted Steel 4 Surface No 4X Stainless Steel 4X Surface No Phase Rating = (L-N + L-G) * Note: 150V (L-N/G) Phase A & C Also available in 600V Delta configurations. For details, please contact GE Power Quality Customer Service at 800 637 1738. 270V (L-N-G) Phase B WMN1-WMN4 Protection Ratings 120S / 120Y Voltage Code L-G L-N HL-N L-G HL-G N-G 400 400 700 400 700 400 — — 800 L-G 800 N-G 800 L-L — L-N L-G N-G 1000 1000 900 L-L — L-G 1500 L-L 600D UL 1449, 2nd Edition Suppression Voltage Ratings (SVR) (assigned UL rating) * — L-L HL-L L-N 480D 1000 1000 700 1200 1500 1800 1000 1500 1000 1500 700 1200 2500 1500 1500 1000 2000 1800 1500 1500 2500 2000 4000 2000 4000 800 L-L 347Y L-N — L-G 220Y / 240Y / 277Y Protection Mode 400 L-L 240H UL 1449, 3rd Edition Voltage Protection Ratings (VPR) (assigned UL rating) 400 N-G 240D — L-G 1500 L-L — WMN12F-WMN12S-WMN4S-WMN4X Protection Ratings 120S / 120Y Voltage Code 240D L-L L-N HL-N L-G HL-G N-G N-G 900 800 700 1200 1200 1800 900 1200 800 1200 700 1200 2100 1500 1200 1200 2000 1500 1500 1500 2500 1800 3000 2000 4000 UL 1449, 2nd Edition Suppression Voltage Ratings (SVR) (assigned UL rating) * 400 400 400 700 400 700 400 — — 800 800 N-G 800 L-L — L-N L-G N-G 1000 1000 900 L-L — L-G 1500 L-L 600D L-G 400 L-G 480D L-N — L-L HL-L L-N 347Y Protection Mode 800 L-L 220Y / 240Y / 277Y UL 1449, 3rd Edition Voltage Protection Ratings (VPR) (assigned UL rating) — L-G 240H — L-G 1500 L-L — * NOTE: SVR Ratings are no longer assigned by UL and are included in the table above for reference purposes only. 12.00 [304.80] Dimensions 9.50 [241.30] 9.28 [235.61] 2X 0.44 [ 11.18] 1.22 [30.99] 0.62 [15.87] 1.25 [31.75] 0.86 [21.84] WMN1D Suffix 24.00 [609.60] 26.50 [673.10] 5.00 [127.00] A A 2X NOTE: All dimensions are for reference only and are shown in Inches [millimeters] 0.44 [ 0.62 [15.87] 11.18] HOLES A 12.01 [305.18] “A” = Recommended conduit entry areas Refer to instruction manual for details 12.00 [304.80] Page 3 • DEA-365 Dimensions 0.86 [21.77] 9.91 [251.76] 21.50 [546.10] 2.74 [69.57] WMN4D Suffix A A 24.00 [609.60] 25.50 [647.70] 0.76 [19.26] 12.65 [321.34] A 20.00 [508.00] 15.33 [389.38] 8x WMN12F Suffix 0.28 [ 7.16] HOLES 14.19 [360.38] 11.63 [295.30] 8.98 [228.04] 1.85 [47.04] 0.57 [14.50] 18.19 [461.98] 16.00 [406.40] 11.63 [295.30] 4.00 [101.60] A 6.00 [152.40] 19.33 [490.98] A 3.85 [97.84] 15.33 [389.38] A 4.00 [101.60] 6.00 [152.40] 0.57 [14.50] 8.98 [228.04] 12.00 [304.80] WMN12S, WMN4S, WMN4X Suffix 10.40 [264.14] 9.23 [234.33] 16.00 [406.37] 19.12 [485.61] A 4x 0.38 [ 9.65] HOLES 17.66 [448.53] 4.00 [101.59] 6.00 [152.39] NOTE: All dimensions are for reference only and are shown in Inches [millimeters] “A” = Recommended conduit entry areas 12.00 [304.77] 6.00 [152.39] A Refer to instruction manual for details 9.23 [234.33] GE Digital Energy – Power Quality 830 W 40th Street, Chicago, IL 60609 USA 800 637 1738 www.gepowerquality.com Information subject to change without notice. Please verify all details with GE. © 2009 General Electric Company All Rights Reserved DEA-365 (12/09) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: GE (General Electric): TR7220Y100WMN4S TR7220Y150WMN4S TR7240D100WMN12S TR7277Y125WMN4D TR7277Y125WMN4X TR7120Y100WMN12F TR7480D080WMN1D TR7120S250WMN1D TR7480D100WMN4X TR7347Y100WMN12S TR7480D150WMN4S TR7240D100WMN4X TR7120Y065WMN4X TR7120S100WMN12F TR7240D300WMN4D TR7120Y200WMN12S TR7480D300WMN4S TR7120Y250WMN12F TR7480D150WMN4D TR7347Y125WMN12F TR7120S300WMN1D TR7240D300WMN4S TR7240D250WMN4D TR7480D250WMN4X TR7240H080WMN1D TR7220Y200WMN12S TR7120S150WMN1D TR7480D200WMN4X TR7240D250WMN4S TR7480D065WMN1D TR7277Y250WMN4X TR7240Y150WMN4S TR7120S125WMN12F TR7240H080WMN12F TR7240D250WMN12F TR7120Y100WMN4S TR7220Y150WMN12S TR7120Y100WMN4X TR7347Y200WMN12F TR7240D065WMN1D TR7277Y150WMN4S TR7277Y250WMN4S TR7120Y065WMN12F TR7240H125WMN12S TR7277Y150WMN4X TR7277Y100WMN4X TR7277Y300WMN4D TR7240H100WMN4X TR7120Y125WMN4D TR7240Y065WMN12S TR7347Y080WMN1D TR7240H150WMN12S TR7240D250WMN1D TR7120Y080WMN12S TR7120Y065WMN4S TR7240H065WMN12S TR7277Y200WMN4D TR7240D200WMN4S TR7240Y200WMN12S TR7277Y100WMN12F TR7120S125WMN4D TR7277Y080WMN12F TR7480D125WMN1D TR7120S125WMN12S TR7240D200WMN4D TR7277Y100WMN4S TR7240Y125WMN12S TR7120Y200WMN4X TR7120Y150WMN4S TR7120Y300WMN4S TR7240Y250WMN12F TR7220Y080WMN4X TR7240Y300WMN4X TR7277Y100WMN12S TR7240Y150WMN4X TR7240Y100WMN4D TR7220Y125WMN12S TR7277Y080WMN1D TR7240D150WMN4D TR7120Y125WMN4X TR7120Y200WMN4S TR7240D250WMN12S TR7347Y150WMN12F TR7240D200WMN12S TR7347Y150WMN4S TR7120Y150WMN12F TR7240Y125WMN4X TR7480D100WMN12S TR7120Y250WMN12S TR7480D150WMN4X TR7240Y125WMN12F TR7347Y300WMN1D TR7277Y080WMN12S TR7220Y100WMN12S TR7220Y100WMN1D TR7347Y080WMN4X TR7240D100WMN4S TR7277Y065WMN12S TR7120Y300WMN4D TR7240Y200WMN4D