GD/GDR SERIES Submersible portable dewatering / residual water PUMPS POWER : 0.5~1HP (0.4~0.75kW) MAX.HEAD : 15m (49feet) MAX.FLOW : 0.33m³/min (19.8m³/h) APPLICATIONS PRODUCT NOMENCLATURE Example 1: GD – 750 Type FEATURE Watt Example 2: GDR – 400 Type Watt GD : ■The GD models are designed for the construction industry because they are lightweight, portable, and durable. The motor frame and mechanical seal bracket are made of aluminum alloy - that provides extra water cooling, to the motor, when water flows through. Features an all new design with exchangeable discharges, that are available in vertical and horizontal orientation. They also provide extra adaptability and flexibility to various conditions of installations, such as: confined spaces, 8 inch narrow wells or shallow water. ■The model is equipped with: double mechanical seals (silicon carbide), epoxy resin cable, watertight body structure that meets IP68 requirements, an auto-cut motor protector, and a watercooling motor. ■The impeller and the hydraulic components are made of a special rubber that is durable and capable of handling construction site dewatering. ■The models are available in the manual version and the automatic version - equipped with a built in floating switch to automatically switch the pump on and off. ■The impeller is made with an urethane rubber that provides extra wear-resistance on construction site dewatering. GDR : ■A water cooling motor with rubber suction pads for residual removal as low as 1 mm (0.39"). ■The best pump for removing water from flat surfaces because of its portability and light weight. ■Equipped with double seals (silicon carbide), epoxy resin cable, IP68, an auto-cut motor protector and rubberized hydraulic components that can withstand any tough applications. ■Standard discharge:Outlet Discharge 1" LOT 1-74(Optional 2" LOT 2-74) GD : ■Civil engineering, dewatering of tunneling and ground works, and for use in storm water sewers. ■Dewatering of fluids containing solids. ■Ease of mobility for use by contractors, installers and service industries. GDR : ■Basement / Pool / Pond water removal. ■Residential, Commercial residue dewatering. Cable Handle Cable base Upper cover Capacitor Auto-cut Bearing Shaft Motor frame Outer cover Rotor Stator Bearing M. seal bracket Mechanical seal Lubricant Oil seal Impeller Casing cover 70 - 1 Strainer DPCEN5-70GD-1506 GD/GDR SERIES Submersible portable dewatering PUMPS GD-400‧GD-750‧GDR-400 SPECIFICATIONS Item Description Liquid Temp. Limits Applications of Use Submersion Depth Frequency Motor Insulation Protection Type Protector Bearing M.seal Impeller Upper Cover Motor Frame Shaft End 0~40°C(32~104°F) Wastewater·Sewage 10m(33feet) 50Hz 2P(3000rpm)·Dry Motor Class B IP68 Auto-cut Ball type Double M.seals Semi-open ADC12 ADC12 SUS410 Material M.seal CA/CE & SiC/SiC Casing Synthetic Rubber Impeller Strainer Cable Optional Model GD-400 GD-400·GD-750 Urethane Rubber + SPCC SUS304 VCT or H07RN-F or SJOW/SOW GDR-400 2" Power Discharge HP(kW) inch(mm) 0.5(0.4) 2"(50) Standard GDR-400 Semi-open Impeller MAX Weight(W/O Cable) Phase 1Ø 1Ø 3Ø 3Ø 3Ø 3Ø 3Ø Solid Passage m-m³/min m-m³/h m-m³/min m-m³/h mm(inch) 1Ø-kg(lb) 3Ø-kg(lb) Voltage 220V 230V 220V 380V 400V 415V 525V 8-0.10 8-6 11-0.24 11-14.4 7(¼") 10.5(23) – GD-750 1(0.75) 2"(50) 11-0.16 11-9.6 15-0.33 15-19.8 7(¼") 12.6(28) – GDR-400 0.5(0.4) 1"(25) 8-0.07 8-4.2 11.5-0.1 11.5-6 – 10.5(23) – PERFORMANCE CURVES 1 0 2 Full load Ampere 3 3.1 3.0 – – – – – 5.2 5.0 – – – – – 3.1 3.0 – – – – – 4 5 l/s m 14 12 GD-7 GD 50 R-4 10 00 GD- 400 8 6 4 2 0 0 0.1 0 0.2 5 Model Power HP(kW) Discharge inch(mm) GD-400 1(0.75) 2"(50) GD-750 1(0.75) 2"(50) GDR-400 0.5 (0.4) 1"(25) 0.3 10 15 Q:m³/min 0.02 0.04 0.06 0.08 0.1 0.2 0.3 Q:m³/h 1.2 2.4 3.6 4.8 6 12 18 10.4 9.8 9.4 8.6 8 3.4 – 15 14.5 14 13.5 12.9 9.6 3.9 11 10.2 8.8 7.3 – – – H:m m-m³/min 70 - 2 l /s Q: H:m m-m³/h 0.5 1 1.5 2 3 4 5 10.2 9.2 8.3 7.4 4.4 – – 14.7 14 13.2 12.3 10.6 7.3 3.9 10.7 9 6.5 – – – – HCP PUMP FILE NO PC-M-E5-GD4001 PUMP PERFORMANCE CURVES GD-400 MODEL DATE: STANDARD SPECIFICATION 50 FREQUENCY 2 DISCHARGE 0.5 OUTPUT REFERENCE SPECIFICATION Hz inch / 50 mm HP 0.4 kW / 8 HEAD Ø V m3/min PHASE/VOLTAGE 1 Ø 220 V 230 V 240 V RATED CURRENT 3.1 A 3.0 A 2.9 A POLE / rpm 2 P kW m 0.1 CAPACITY HP A 2780 / rpm DIRECT START METHOD B INSULATION CLASS REMARK 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0.22 m3/min 0.24 100 90 12 HEAD 10 8 m 6 80 HEAD 70 60 50 EFF. 40 EFF. 14 0 % 30 4 20 2 10 0 0 0 1 0 2 2 4 6 3 8 10 4 12 14 l/s m3/h OUTPUT 0.6 kW 0.4 0.2 0 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 CAPACITY HCP PUMP MANUFACTURER CO.,LTD. 70 - 3 0.22 0.24 m3/min HCP PUMP FILE NO PC-M-E5-GD7501 PUMP PERFORMANCE CURVES GD-750 MODEL DATE: STANDARD SPECIFICATION REFERENCE SPECIFICATION 50 FREQUENCY DISCHARGE 2 inch / OUTPUT 1 HP Hz / 50 mm 0.75 kW 11 HEAD m m /min PHASE/VOLTAGE 1 Ø 220 V 230 V 240 V RATED CURRENT 5.2 A 5.0 A 4.8 A POLE / rpm 2 P kW 3 0.16 CAPACITY HP Ø A 2780 / V rpm DIRECT START METHOD B INSULATION CLASS REMARK 0.05 0.1 0.15 0.2 0.25 0.3 0.35 m3/min 0.4 0.45 100 90 16 HEAD 14 80 70 HEAD 12 m 60 10 EFF. 8 50 40 6 EFF. 18 0 % 30 4 20 2 10 0 0 0 1 0 2 3 5 4 10 5 15 6 l/s 7 20 m3/h 25 OUTPUT 1 kW 0.8 0.6 0.4 0.2 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 CAPACITY HCP PUMP MANUFACTURER CO.,LTD. 70 - 4 0.45 m3/min HCP PUMP FILE NO PC-M-E5-GDR4001 PUMP PERFORMANCE CURVES GDR-400 MODEL DATE: STANDARD SPECIFICATION REFERENCE SPECIFICATION 50 FREQUENCY 1 DISCHARGE 0.5 OUTPUT Hz inch / 25 mm HP 0.4 kW / 8 HEAD Ø V m m /min PHASE/VOLTAGE 1 Ø 220 V 230 V 240 V RATED CURRENT 3.1 A 3.0 A 2.9 A POLE / rpm 2 P kW 3 0.07 CAPACITY HP A 2780 / rpm DIRECT START METHOD B INSULATION CLASS REMARK 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 100 90 12 HEAD 80 HEAD 10 8 m 6 70 60 50 40 EFF. EFF. 14 m3/min % 30 4 20 2 10 0 0 0 0.2 0 0.4 0.6 1 0.8 2 1 3 1.2 1.4 4 1.6 5 1.8 6 2 7 m3/h OUTPUT 0.6 kW l/s 0.4 0.2 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 CAPACITY HCP PUMP MANUFACTURER CO.,LTD. 70 - 5 0.11 0.12 m3/min 70 - 6 70 - 7 70 - 8 70 - 9 70 - 10 70 - 11 70 - 12