advertisement
GD/GDR SERIES
Submersible portable dewatering / residual water PUMPS
POWER : 0.5~1HP (0.4~0.75kW)
MAX.HEAD : 15m (49feet)
MAX.FLOW : 0.33m³/min (19.8m³/h)
APPLICATIONS
PRODUCT NOMENCLATURE
Example 1: GD – 750
Type
FEATURE
Watt
Example 2: GDR – 400
Type
Watt
GD :
■The GD models are designed for the construction industry
because they are lightweight, portable, and durable. The motor
frame and mechanical seal bracket are made of aluminum alloy
- that provides extra water cooling, to the motor, when water
flows through. Features an all new design with exchangeable
discharges, that are available in vertical and horizontal
orientation. They also provide extra adaptability and flexibility to
various conditions of installations, such as: confined spaces, 8
inch narrow wells or shallow water.
■The model is equipped with: double mechanical seals (silicon
carbide), epoxy resin cable, watertight body structure that meets
IP68 requirements, an auto-cut motor protector, and a watercooling motor.
■The impeller and the hydraulic components are made of a special
rubber that is durable and capable of handling construction site
dewatering.
■The models are available in the manual version and the automatic
version - equipped with a built in floating switch to automatically
switch the pump on and off.
■The impeller is made with an urethane rubber that provides extra
wear-resistance on construction site dewatering.
GDR :
■A water cooling motor with rubber suction pads for residual
removal as low as 1 mm (0.39").
■The best pump for removing water from flat surfaces because
of its portability and light weight.
■Equipped with double seals (silicon carbide), epoxy resin cable,
IP68, an auto-cut motor protector and rubberized hydraulic
components that can withstand any tough applications.
■Standard discharge:Outlet Discharge 1" LOT 1-74(Optional 2" LOT 2-74)
GD :
■Civil engineering, dewatering of tunneling and ground works, and for
use in storm water sewers.
■Dewatering of fluids containing solids.
■Ease of mobility for use by contractors, installers and service
industries.
GDR :
■Basement / Pool / Pond water removal.
■Residential, Commercial residue dewatering.
Cable
Handle
Cable base
Upper cover
Capacitor
Auto-cut
Bearing
Shaft
Motor frame
Outer cover
Rotor
Stator
Bearing
M. seal bracket
Mechanical seal
Lubricant
Oil seal
Impeller
Casing cover
70 - 1
Strainer
DPCEN5-70GD-1506
GD/GDR SERIES Submersible portable dewatering PUMPS
GD-400‧GD-750‧GDR-400
SPECIFICATIONS
Item
Description
Liquid Temp.
Limits
Applications
of Use
Submersion Depth
Frequency
Motor
Insulation
Protection
Type
Protector
Bearing
M.seal
Impeller
Upper Cover
Motor Frame
Shaft End
0~40°C(32~104°F)
Wastewater·Sewage
10m(33feet)
50Hz
2P(3000rpm)·Dry Motor
Class B
IP68
Auto-cut
Ball type
Double M.seals
Semi-open
ADC12
ADC12
SUS410
Material
M.seal
CA/CE & SiC/SiC
Casing
Synthetic Rubber
Impeller
Strainer
Cable
Optional
Model
GD-400
GD-400·GD-750
Urethane Rubber + SPCC
SUS304
VCT or H07RN-F or SJOW/SOW
GDR-400 2"
Power Discharge
HP(kW) inch(mm)
0.5(0.4)
2"(50)
Standard
GDR-400
Semi-open Impeller
MAX
Weight(W/O Cable)
Phase
1Ø
1Ø
3Ø
3Ø
3Ø
3Ø
3Ø
Solid
Passage
m-m³/min m-m³/h m-m³/min m-m³/h mm(inch) 1Ø-kg(lb) 3Ø-kg(lb) Voltage 220V 230V 220V 380V 400V 415V 525V
8-0.10
8-6
11-0.24
11-14.4
7(¼")
10.5(23)
–
GD-750
1(0.75)
2"(50)
11-0.16
11-9.6
15-0.33
15-19.8
7(¼")
12.6(28)
–
GDR-400
0.5(0.4)
1"(25)
8-0.07
8-4.2
11.5-0.1
11.5-6
–
10.5(23)
–
PERFORMANCE CURVES
1
0
2
Full load
Ampere
3
3.1
3.0
–
–
–
–
–
5.2
5.0
–
–
–
–
–
3.1
3.0
–
–
–
–
–
4
5
l/s
m
14
12
GD-7
GD
50
R-4
10
00
GD-
400
8
6
4
2
0
0
0.1
0
0.2
5
Model
Power
HP(kW)
Discharge
inch(mm)
GD-400
1(0.75)
2"(50)
GD-750
1(0.75)
2"(50)
GDR-400
0.5 (0.4)
1"(25)
0.3
10
15
Q:m³/min
0.02
0.04
0.06
0.08
0.1
0.2
0.3
Q:m³/h
1.2
2.4
3.6
4.8
6
12
18
10.4
9.8
9.4
8.6
8
3.4
–
15
14.5
14
13.5
12.9
9.6
3.9
11
10.2
8.8
7.3
–
–
–
H:m
m-m³/min
70 - 2
l /s
Q:
H:m
m-m³/h
0.5
1
1.5
2
3
4
5
10.2
9.2
8.3
7.4
4.4
–
–
14.7
14
13.2
12.3
10.6
7.3
3.9
10.7
9
6.5
–
–
–
–
HCP PUMP
FILE NO
PC-M-E5-GD4001
PUMP PERFORMANCE CURVES
GD-400
MODEL
DATE:
STANDARD SPECIFICATION
50
FREQUENCY
2
DISCHARGE
0.5
OUTPUT
REFERENCE SPECIFICATION
Hz
inch /
50
mm
HP
0.4
kW
/
8
HEAD
Ø
V
m3/min
PHASE/VOLTAGE
1 Ø 220 V 230 V 240 V
RATED CURRENT
3.1 A 3.0 A 2.9 A
POLE / rpm
2
P
kW
m
0.1
CAPACITY
HP
A
2780
/
rpm
DIRECT
START METHOD
B
INSULATION CLASS
REMARK
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.2
0.22
m3/min
0.24
100
90
12
HEAD
10
8
m
6
80
HEAD
70
60
50
EFF.
40
EFF.
14
0
%
30
4
20
2
10
0
0
0
1
0
2
2
4
6
3
8
10
4
12
14
l/s
m3/h
OUTPUT
0.6
kW
0.4
0.2
0
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
0.16
0.18
0.2
CAPACITY
HCP PUMP MANUFACTURER CO.,LTD.
70 - 3
0.22
0.24
m3/min
HCP PUMP
FILE NO
PC-M-E5-GD7501
PUMP PERFORMANCE CURVES
GD-750
MODEL
DATE:
STANDARD SPECIFICATION
REFERENCE SPECIFICATION
50
FREQUENCY
DISCHARGE
2
inch /
OUTPUT
1
HP
Hz
/
50
mm
0.75
kW
11
HEAD
m
m /min
PHASE/VOLTAGE
1 Ø 220 V 230 V 240 V
RATED CURRENT
5.2 A 5.0 A 4.8 A
POLE / rpm
2
P
kW
3
0.16
CAPACITY
HP
Ø
A
2780
/
V
rpm
DIRECT
START METHOD
B
INSULATION CLASS
REMARK
0.05
0.1
0.15
0.2
0.25
0.3
0.35
m3/min
0.4
0.45
100
90
16
HEAD
14
80
70
HEAD
12
m
60
10
EFF.
8
50
40
6
EFF.
18
0
%
30
4
20
2
10
0
0
0
1
0
2
3
5
4
10
5
15
6
l/s
7
20
m3/h
25
OUTPUT
1
kW
0.8
0.6
0.4
0.2
0
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
CAPACITY
HCP PUMP MANUFACTURER CO.,LTD.
70 - 4
0.45
m3/min
HCP PUMP
FILE NO
PC-M-E5-GDR4001
PUMP PERFORMANCE CURVES
GDR-400
MODEL
DATE:
STANDARD SPECIFICATION
REFERENCE SPECIFICATION
50
FREQUENCY
1
DISCHARGE
0.5
OUTPUT
Hz
inch /
25
mm
HP
0.4
kW
/
8
HEAD
Ø
V
m
m /min
PHASE/VOLTAGE
1 Ø 220 V 230 V 240 V
RATED CURRENT
3.1 A 3.0 A 2.9 A
POLE / rpm
2
P
kW
3
0.07
CAPACITY
HP
A
2780
/
rpm
DIRECT
START METHOD
B
INSULATION CLASS
REMARK
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.1
0.11
0.12
100
90
12
HEAD
80
HEAD
10
8
m
6
70
60
50
40
EFF.
EFF.
14
m3/min
%
30
4
20
2
10
0
0
0
0.2
0
0.4
0.6
1
0.8
2
1
3
1.2
1.4
4
1.6
5
1.8
6
2
7
m3/h
OUTPUT
0.6
kW
l/s
0.4
0.2
0
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0.09
0.1
CAPACITY
HCP PUMP MANUFACTURER CO.,LTD.
70 - 5
0.11
0.12
m3/min
70 - 6