ENGLISH PRIMARY TRANSFER STANDARD RD-22 PRIMARY TRANSFER STANDARD Typical Accuracy: within traceability uncertainties Worst Case Accuracy: ±0.01% @ PF≥0.5 DC to AC Transfer Accuracy: ±0.005% INTRODUCTION OPERATIONAL HIGHLIGH TS The RD-22 primary transfer standard utilizes Radian Research’s Dytronic measurement technology that features a Radian Research designed Integrating Analog to Digital Signal Converter based upon a charge balance conversion principle. The RD-22 also employs a Radian Research electronically compensated concentric core current comparator transformer. The RD-22 can be used to transfer accurate and traceable measurements from Radian Research’s calibration laboratory. Alternatively, it can be calibrated directly by National Metrology Laboratory. The RD-22 represents state-of-the-art technology in a commercially available true DC to AC accuracy transfer reference. The RD-22 has typical AC measurement accuracies within the limits of traceability. Repeatability of 1 ppm can be attained at 120 V and 5 A inputs for specific models. The RD-22 can optionally analyze harmonic waveforms through the 150th harmonic order. A second option enables the RD-22 to automatically calculate and display the degree of error from the standards being tested. The analog sense option allows for testing of transducers and other devices that provide an analog current output instead of a digital pulse output. The RD-22 also provides a serial communications port for direct connection to the RS-232 serial port of a personal computer. This current comparator is autoranging and external to the standard, allowing for non-galvanic current connection to the unit. These two new technologies combine with added Radian Research technology features to provide the highest degree of accuracy, stability and versatility ever offered in a primary transfer standard. TECHNICAL DATA Current range 1 × 20mA … 125 (200)A auto-ranging Voltage range 1 × 60 … 600V auto-ranging Auxiliary power range 1 × 60 … 600V auto-ranging Frequency of the fundamental 40 … 70Hz (1) Power Factor range Any Auxiliary power converter input 120V or 240V Auxiliary Power DC input 24V nominal Operating temperature range +18°C … +30°C Humidity 0 … 95%, non-condensing Measurement modes 2 wire active and reactive Typical Accuracy: within traceability uncertainties Worst Case Accuracy: ±0.01% @ PF≥0.5 Accuracy DC to AC Transfer Accuracy: ±0.005% Display Gate input BNC with 150 ohms pull up to 5 volts, clamped at 5.7 volts Gate Rate 200ns pulse width minimum, maximum 20Hz repetition rate Output type Open collector, clamped at 27 volts BNC pulse output default value 0.00001 Wh/pulse but may be reprogrammed Frequency Max 2.1MHz (200ns pulse width minimum) Display Yes Other possible features (upon request) Built-in comparator Harmonic analysis (1) Operating range. Specified range from 45 to 65Hz. For additional technical details, please contact our sales department (sales@metertest.eu) 34643/2016-06-16 MeterTest Sp. z o.o. | Lukasinskiego St. 26 b. 21, 58-100, Swidnica, Poland meter-test-equipment.com +48 74 856 63 92 sales@metertest.eu