MS116 - MS132 Manual Motor Starters up to 32 A

advertisement
MS116 - MS132 Manual Motor Starters
up to 32 A
Manual Motor Starters
Overview..................................................................................................................................1/79
MS116 Manual Motor Starter - up to 16 A
Ordering Details........................................................................................................................1/81
Main Technical Data.................................................................................................................1/82
MS132 Manual Motor Starter - up to 32 A
Ordering Details........................................................................................................................1/83
Main Technical Data.................................................................................................................1/84
Main Accessory Ordering Details.............................................................................................1/85
Dimensions...............................................................................................................................1/88
1/78 | ABB
MS116
MS132
(0.10 ... 16 A)
(0.10 ... 32 A)
for Manual Motor Starters
S1-M2-25
Main Accessories
PS1-..-65
S1-M1-25
3-phase busbar
up to 65 A
PS1-..-65
3-phase busbar
up to 92 A
BS1-3
HK1
S1-M1-25
PS1-..-100
SK1
BS1-3
HK1
HK1
SK1
SA1
CK1
MS116
AA1
HK1
CK1
UA1
MS132
ABB | 1/79
Manual Motor
Starters
MS116
Certifications and approvals
Electromagnetic trip a multiple of the rated current
Phase loss sensitivity
Switch position
cULus
CCC
GOST
GOST-FIRE BV
GL
LR
MS132
DNV
ABS
RMRS
CE
cULus
9.75 ... 15 x In
CCC
GOST
GOST-FIRE
GL
yes
yes
ON/OFF
ON/OFF/TRIP
Magnetic trip indication
-
yes
Lockable without accessories
-
yes
Disconnecting feature
Width
Setting range
Rated operational voltage Ue
Rated frequency
Trip class
Short-circuit breaking capacity Ics
Ambient air temperature open compensated
yes
yes
45 mm
45 mm
0.1 ... 16 A
0.1 ... 32 A
600 V AC
600 V AC
50 Hz / 60 Hz
50 Hz / 60 Hz
10A
10
up to 50 kA
up to 100 kA
-25 ... +55 °C
-25 ... +60 °C
Main Accessories
Front mounting
HKF1
Side mounting
HK1
Tripped alarm
SK1
Auxiliary
contacts
Signaling
contacts
Short-circuit alarm
–
CK1
Shunt trip
AA1
Undervoltage release
UA1
3-phase busbar
PS1
Feeder terminals
S1
Auxiliary
trip units
Busbar
systems
1/80 | ABB
LR
9.75 ... 15 x In
ABS
CE
MS116 Manual Motor Starter
With Thermal and Electromagnetic Protection
0.10 ... 16.0 A
Class 10A
Application
cULus
CCC
BV
GL
CE
GOST GOST-FIRE
LR
DNV
ABS
RMRS
–– Short-circuit protection
–– Overload protection
–– Trip class 10A
–– Phase loss sensitivity
–– ON/OFF switching functionality
–– Disconnecting feature
–– Suitable for three- and single phase applications
Description
–– 45 mm width
–– One range of common accessories for MS116 & MS132
Ordering Details
Setting ranges
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
at 600 V AC
at 480 V AC
kA
5
5
5
5
5
5
5
5
5
5
5
5
kA
30
30
30
30
30
30
30
18
18
18
18
18
Rated instantaneous Catalog number
short-circuit current
setting
A
1.25 ... 1.87
1.95 ... 2.92
3.12 ... 4.68
4.91 ... 7.37
9.20 ... 13.8
14.7 ... 22.1
23.0 ... 34.5
40.0 ... 60.0
63.0 ... 94.5
120 ... 180
144 ... 216
192 ... 288
MS116-0.16
MS116-0.25
MS116-0.4
MS116-0.63
MS116-1.0
MS116-1.6
MS116-2.5
MS116-4.0
MS116-6.3
MS116-10
MS116-12
MS116-16
List price Pack(ing) Weight
pieces
kg/lb (1 pce)
1
1
1
1
1
1
1
1
1
1
1
1
0.225/0.50
0.225/0.50
0.225/0.50
0.225/0.50
0.225/0.50
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
Main Dimensions mm, inches
80.1 3.15"
70 2.76"
43.5 1.71"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
45 1.77"
90 3.54"
MS116
Short-circuit
DISCOUNT SCHEDULE DS-MA, AC1010
ABB | 1/81
MS116 Manual Motor Starter
Technical Data
0.10 ... 16.0 A
Class 10A
Main Technical Data
MS116
Manual Motor Starter Types
Standards
General data
Conformity to standards
IEC/EN60947-1, IEC/EN60947-2, IEC/EN60947-4-1, UL 508, CSA C22.2 No. 14
Phase loss sensitivity
(acc. to IEC/EN 60947-4-1)
yes
Disconnecting feature
(acc. to IEC/EN 60947-2)
yes
Mounting position
Position 1-6
Degree of protection
IP 20
(acc. to IEC 60947-1)
Mechanical durability
100000 cycles
Electrical durability
100000 cycles
Utilization category
A
UL/CSA
Main circuit
Max. operational voltage
Short-circuit rating
600 V AC
480 V AC
0.16 A ≤ Ie ≤ 2.5 A
30 kA
2.5 A < Ie ≤ 16 A
18 kA
600 V AC
Connecting
capacity
5 kA
Stranded
1 or 2 x
AWG 16 ... 12
Flexible without ferrule
1 or 2 x
AWG 16 ... 12
Stripping length
9 mm
Tightening torque
10 lb.in
Rated operational voltage Ue
690 V AC
Rated operational current Ie
up to 16 A
Conventional free air thermal current Ith
up to 16 A
Rated frequency
50 / 60 Hz
Trip class
10A
Isolation data
Rated impulse withstand voltage Uimp
6 kV
(acc. to IEC/EN 60947-1)
Rated insulation voltage Ui
690 V
Environmental
data
Ambient air temperature
IEC
Main circuit
Operation
Open - compensated
-25 ... +55 °C
Open
-25 ... +70 °C
Storage
Connecting
capacity
1/82 | ABB
-50 ... +80 °C
Vibration
(acc. to IEC/EN 60068-2-6)
Shock
(acc. to IEC/EN 60068-2-27)
5 g / 3-150 Hz
25 g / 11 ms
Rigid
1 or 2 x
1 ... 4 mm²
Flexible with ferrule
1 or 2 x
0.75 ... 2.5 mm²
Flexible without ferrule
1 or 2 x
0.75 ... 2.5 mm²
Stripping length
9 mm
Tightening torque
0.8 ... 1.2 Nm
MS132 Manual Motor Starter
With Thermal and Electromagnetic Protection
0.10 ... 32.0 A
Class 10
Application
cULus
CCC
GL
LR
GOST GOST-FIRE
ABS
CE
–– Short-circuit protection
–– Overload protection
–– Trip class 10
–– Phase loss sensitivity
–– ON/OFF switching functionality
–– Disconnecting feature
–– Suitable for three- and single phase applications.
Description
–– 45 mm width
–– Lockable handle
–– Clear position of the handle ON/OFF/TRIP
–– Magnetic tripping optically signalled in the front
–– One range of common accessories for MS116 & MS132.
Ordering Details
Setting ranges
at 600 V AC
at 480 V AC
kA
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
kA
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
Rated instantaneous
short-circuit current
setting
A
1.25 ... 1.87
1.95 ... 2.92
3.12 ... 4.68
4.91 ... 7.37
9.20 ... 13.8
14.7 ... 22.1
23.0 ... 34.5
40.0 ... 60.0
63.0 ... 94.5
120 ... 180
144 ... 216
192 ... 288
240 ... 360
300 ... 450
384 ... 576
Catalog number
List price Pack(ing) Weight
pieces
kg/lb (1 pce)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
MS132-0.16
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.6
MS132-2.5
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-20
MS132-25
MS132-32
0.215/0.47
0.215/0.47
0.215/0.47
0.215/0.47
0.215/0.47
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
0.265/0.58
0.310/0.68
0.310/0.68
0.310/0.68
0.310/0.68
0.310/0.68
Main Dimensions mm, inches
MS132-12 ... MS132-32
81.3 3.20"
45 1.77"
97.8 3.85"
43.5 1.71"
45 1.77"
5.5 0.22"
5.5 0.22"
43.3 1.70"
45 1.77"
72.4 2.85"
45 1.77"
81.1 3.19"
72.2 2.84"
35 mm EN/IEC 60715
MS132-0.16 ... MS132-10
35 mm EN/IEC 60715
MS132-32
A ... A
0.10 ... 0.16
0.16 ... 0.25
0.25 ... 0.40
0.40 ... 0.63
0.63 ... 1.00
1.00 ... 1.60
1.60 ... 2.50
2.50 ... 4.00
4.00 ... 6.30
6.30 ... 10.0
8.00 ... 12.0
10.0 ... 16.0
16.0 ... 20.0
20.0 ... 25.0
25.0 ... 32.0
90 3.54"
MS132-10
Short-circuit
DISCOUNT SCHEDULE DS-MA, AC1010
ABB | 1/83
MS132 Manual Motor Starter
Technical Data
0.10 ... 32.0 A
Class 10
Main Technical Data
MS132
Manual Motor Starter Types
up to 10 A
Standards
General data
Conformity to standards
up to 16 A
up to 32 A
IEC/EN60947-1, IEC/EN60947-2, IEC/EN60947-4-1, UL 508, CSA C22.2 No. 14
Phase loss sensitivity
(acc. to IEC/EN 60947-4-1)
yes
Disconnecting feature
(acc. to IEC/EN 60947-2)
yes
Mounting position
Position 1-6
Degree of protection
IP 20
(acc. to IEC 60947-1)
Mechanical durability
100000 cycles
Electrical durability
50000 cycles
Utilization category
A
UL/CSA
Main circuit
Max. operational voltage
Short-circuit rating
Connecting
capacity
600 V AC
480 V AC
30 kA
600 V AC
18 kA
Type E rated up to 32A
Stranded
1 or 2 x
AWG 16 ... 12
AWG 16 ... 12
AWG 12 ... 8
Flexible without ferrule
1 or 2 x
AWG 16 ... 12
AWG 16 ... 12
AWG 12 ... 8
Stripping length
9 mm
10 mm
10 mm
Tightening torque
10 ... 12 lb.in
14 lb.in
18 lb.in
Rated operational voltage Ue
690 V AC
Rated operational current Ie
up to 10 A
up to 16 A
up to 32 A
Conventional free air thermal current Ith
up to 10 A
up to 16 A
up to 32 A
Rated frequency
50 / 60 Hz
Trip class
10 (10A for MS132-0.16) 10
Rated impulse withstand voltage Uimp
6 kV
IEC
Main circuit
Isolation data
(acc. to IEC/EN 60947-1) Rated insulation voltage Ui
690 V
Environmental
data
Open - compensated
-25 ... +60 °C
Open
-25 ... +70 °C
Ambient air temperature
Operation
Storage
Connecting
capacity
1/84 | ABB
10
-50 ... +80 °C
Vibration
(acc. to IEC/EN 60068-2-6)
5 g / 3-150 Hz
Shock
(acc. to IEC/EN 60068-2-27)
25 g / 11 ms
Rigid
1 or 2 x
1 ... 4 mm²
1 ... 4 mm²
2.5 ... 6 mm²
Flexible with ferrule
1 or 2 x
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
1 ... 6 mm²
Flexible without ferrule
1 or 2 x
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
1 ... 6 mm²
Stripping length
9 mm
10 mm
10 mm
Tightening torque
0.8 ... 1.2 Nm
1.5 Nm
2.0 Nm
Manual Motor Starters
Main Accessories
Auxiliary contacts
Manual Motor Starters
MS116
MS132
Aux. contacts
N.O.
N.C.
List price Pack(ing) Weight
pieces kg/lb (1 pce)
Catalog number
Auxiliary contacts, mountable on front
HKF1-11
•
•
1
•
•
•
•
•
•
1
2
0
•
•
2
1
MS132-HKF1-11
10
0.016/0.035
MS132-HK1-11
MS132-HK1-20
MS132-HK1-02
2
2
2
0.035/0.077
0.035/0.077
0.035/0.077
Auxiliary contacts, mountable on the right, max. 2 pieces
1
0
2
Auxiliary contacts with lead contacts, mountable on the right, also to use with undervoltage release
0
MS132-HK1-20L
2
0.035/0.077
MS132-SK1-11
MS132-SK1-20
MS132-SK1-02
2
2
2
0.035/0.077
0.035/0.077
0.035/0.077
2
2
2
0.035/0.077
0.035/0.077
0.035/0.077
Signaling contacts
Signaling contacts for tripped alarm, mountable on the right
HK1-11
•
•
•
•
•
•
1
2
0
-
•
•
•
1
2
0
1
0
2
Signaling contacts for short-circuit alarm, mountable on the right
1
0
2
MS132-CK1-11
MS132-CK1-20
MS132-CK1-02
Auxiliary trip units
Manual Motor Starters
MS116
Rated control Catalog number
supply voltage
MS132
List price Pack(ing) Weight
pieces kg/lb (1 pce)
Shunt trip, mountable on the left
AA1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
24 V 50/60 Hz MS132-AA1-24
110 V 50/60 Hz MS132-AA1-110
200 ... 240 V 50/60 Hz MS132-AA1-230
1
1
1
0.10/0.22
0.10/0.22
0.10/0.22
1
1
1
1
1
0.10/0.22
0.10/0.22
0.10/0.22
0.10/0.22
0.10/0.22
Undervoltage release, mountable on the left
UA1
24 V 60 Hz
110 V 50 Hz - 120 V 60 Hz
208 V 60 Hz
230 V 50 Hz - 240 V 60 Hz
575 V 60 Hz
MS132-UA1-24
MS132-UA1-120
MS132-UA1-208
MS132-UA1-230
MS132-UA1-575
Manual motor starter with accessories
HK1
HK1
SK1
HK1
SK1
HK1
HK1
SK1
HK1
HK1
CK1
MS132
CK1
HKF1-11
AA1
AA1
UA1
HKF1-11
C1
D1
UA1-..
D2
41
55
65
32
42
56
66
HK1-02
C2
U<
31
1 L1 3 L2 5 L3
2 T1 4 T2 6 T3
43
57
67
34
44
58
68
21
33
41
57
65
14
22
34
42
58
66
HK1-11
AA1-..
D1
SK1-11
UA1-..
HKF1
HK1
SK1
CK1
AA1
UA1
Auxiliary contacts, mountable on front
Auxiliary contacts, mountable on the right
Signaling contacts for tripped alarm
Signaling contacts for short-circuit alarm
Shunt trip
Undervoltage release
D2
31
41
55
65
75
85
32
42
56
66
76
86
HK1-02
C2
U<
SK1-20
13
HKF1-11
I> I> I>
C1
SK1-02
33
HK1-20
UA1
1 L1 3 L2 5 L3
SK1-02
33
43
57
67
77
87
34
44
58
68
78
88
HK1-20
SK1-20
CK1-20
13
21
33
41
57
65
77
85
14
22
34
42
58
66
78
86
HKF1-11
HK1-11
SK1-11
CK1-11
I> I> I>
2 T1 4 T2 6 T3
DISCOUNT SCHEDULE DS-MA, AC1010
ABB | 1/85
Manual Motor Starters
Main Accessories
3-phase busbar systems
Manual Motor Starters
MS116
MS132
Number
of MMS
Number of
aux. contacts
Catalog number
List price Pack(ing) Weight
pieces kg/lb (1 pce)
3-phase busbar up to 65 A
PS1-..-65
PS1-..-100
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
2
3
4
5
2
3
4
5
2
3
4
5
0
0
0
0
1
1
1
1
2
2
2
2
MS132-PS1-2-0-65
MS132-PS1-3-0-65
MS132-PS1-4-0-65
MS132-PS1-5-0-65
MS132-PS1-2-1-65
MS132-PS1-3-1-65
MS132-PS1-4-1-65
MS132-PS1-5-1-65
MS132-PS1-2-2-65
MS132-PS1-3-2-65
MS132-PS1-4-2-65
MS132-PS1-5-2-65
10
10
10
10
10
10
10
10
10
10
10
10
0.034/0.07
0.055/0.12
0.077/0.17
0.098/0.22
0.036/0.08
0.060/0.13
0.087/0.19
0.108/0.24
0.040/0.09
0.067/0.15
0.095/0.21
0.122/0.27
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3
4
5
3
4
5
3
0
0
0
1
1
1
2
MS132-PS1-3-0-100
MS132-PS1-4-0-100
MS132-PS1-5-0-100
MS132-PS1-3-1-100
MS132-PS1-4-1-100
MS132-PS1-5-1-100
MS132-PS1-3-2-100
10
10
10
10
10
10
10
0.084/0.19
0.117/0.26
0.154/0.34
0.094/0.21
0.134/0.30
0.172/0.38
0.105/0.23
Remarks
Connecting
capacity AWG
Catalog number
Flat
High
4
4
MS132-S1-M1-25
MS132-S1-M2-25
10
10
0.038/0.08
0.051/0.11
4
2
MS132-S1-M3-25
MS132-S1-M3-35
10
10
0.042/0.09
0.060/0.13
MS132-BS1-3
50
0.003/0.01
3-phase busbar up to 92 A
S1-M1-25
3-phase feeder terminals
Busbar types
65 A
S1-M3-25
92 A
List Price Pack(ing) Weight
pieces kg/lb (1 pce)
3-phase feeder terminals
•
•
-
•
•
•
•
•
3-phase feeder terminals for CSA/UL type E
S1-M3-35
Cover for 3-phase busbars
Locking
Manual Motor Starters
MS116
SA1
Catalog number
MS132
List Price Pack(ing) Weight
pieces kg/lb (1 pce)
Locking device
•
•
•
-
Lock adapter MS132-SA1
Padlock + 2 keys MS132-SA2
Lock adapter + padlock + 2 keys MS132-SA3
•
-
3-phase busbar up to 65 A
10
10
10
3-phase busbar up to 92 A
S1-M2-25
PS1-..-65
PS1-..-100
S1-M1-25
S1-M1-25
BS1-3
MS132
BS1-3
MS132
MS116
SA1
MS132
DISCOUNT SCHEDULE DS-MA, AC1010
1/86 | ABB
0.003/0.01
0.020/0.04
0.050/0.11
Manual Motor Starter
Main Accessories
6 MM Handle Enclosures
Catalog number
MS116
•
•
•
•
List price
MS132
•
•
•
•
MS132-MSMN
MSHD-LB
MS116/132 handle, yellow, NEMA 1, 3R, 12, 6MM, no trip indicator MSHD-YB
MS132 handle, Black ON-TRIP-OFF, NEMA 1, 3R, 12, 6MM
MSHD-LTB
MS132 handle, Yellow, ON-TRIP-OFF, NEMA 1, 3R, 12, 6MM
MSHD-LTY
Shaft for selector hanle, 6mm x 180mm long
OXS6X180
MS116/132 shaft coupler, 6MM
MS116/132 handle, black, NEMA 1, 3R, 12, 6MM, no trip indicator
Pack(ing)
pieces
10
1
1
1
1
1
Weight
kg/lb (1 pce)
Complete kits for through-the door operation (includes 180mm x 6mm shaft, selector and adaptor)
•
•
•
•
•
•
Black handle, without trip position
Yellow handle, without trip position
Black handle, with trip position
Yellow handle, with trip position
MS132-B-KIT
MS132-Y-KIT
MS132-BF-KIT
MS132-YF-KIT
1
1
1
1
DISCOUNT SCHEDULE DS-MA, AC1010
ABB | 1/87
MS132 Manual Motor Starter
With Thermal and Electromagnetic Protection
Dimensions mm, inches
80.1 3.15"
81 3.19"
70 2.76"
18 0.71"
43.5 1.71"
9 0.35"
MS116
+ UA1, AA1, SK1, HK1, HKF1-11
81.1 3.19"
81.3 3.20"
72.4 2.85"
45 1.77"
43.5 1.71"
5.5 0.22"
18 0.71"
72.2 2.84"
81 3.19"
43.3 1.70"
9 0.35"
86.5 3.41"
MS132-0.16 ... MS132-10
57.8 2.28"
90 3.54"
45 1.77"
35 mm EN/IEC 60715
45 1.77"
9 0.35"
97.8 3.85"
5.5 0.22"
35 mm EN/IEC 60715
90 3.54"
57.8 2.28"
45 1.77"
90 3.54"
MS116
45 1.77"
85.6 3.37"
9 0.35"
90 3.54"
5.5 0.22"
35 mm EN/IEC 60715
45 1.77"
MS132-0.16 ... MS132-10
+ UA1, AA1, SK1, HK1, CK1, HKF1-11
81.1 3.19"
81 3.19"
72.2 2.84"
MS132-12 ... MS132-32
1/88 | ABB
18 0.71"
43.3 1.70"
86.5 3.41"
9 0.35"
MS132-12 ... MS132-32
+ UA1, AA1, SK1, HK1, CK1, HKF1-11
57.8 2.28"
97.8 3.85"
9 0.35"
45 1.77"
5.5 0.22"
35 mm EN/IEC 60715
97.8 3.85"
45 1.77"
45 1.77"
Motor Starting Solutions
Open Type Version, in Kit Form
Overview..................................................................................................................................1/91
Starters Protected by Manual Motor Starters
Across-the-Line Starters.........................................................................................................1/93
Reversing Starters...................................................................................................................1/97
Dimensions
Starters Protected by Manual Motor Starters
– Direct-on-Line Starters.......................................................................................................1/101
– Reversing Starters..............................................................................................................1/102
1/90 | ABB
Motor Starting Solutions
Open Type Version, in Kit Form
Starters Protected by Manual Motor Starters
Across-the-Line Starters
I>
Reversing Starters
I>
MS...
Manual motor starter
MS...
Manual motor starter
BEA...
Connecting link
BEA...
Connecting link
BER..-4
Connection set
AF...
Contactor
AF...
Contactor
mechanical &
electrical
interlock set
A2-A2
Connection
Starters Protected by Thermal Overload Relays
Across-the-Line Starters
Reversing Starters
BER..-4
Connection set
AF...
Contactor
A2-A2
Connection
AF...
Contactor
Thermal overload relay
VEM4
mechanical &
electrical
interlock set
TF42
Thermal overload relay
VEM4 mechanical and electrical interlock set including: VM4 mechanical interlock unit including 2 fixing clips and VE4 electrical interlock block with A2-A2 connection
ABB | 1/91
Starters Protected
by Manual Motor Starters
Switching of 3-phase Cage Motors
Horsepower rating 600 V
Across-the-Line Starters
Reversing Starters
480 V
0.1 ... 20 HP
0.1 ... 25 HP
600 V
0.1 ... 25 HP
0.1 ... 25 HP
Short-circuit ratings
Manual motor starters
Contactors
AC / DC Operated
Up to 50 kA
Up to 50 kA
MS116 ... MS132
MS116 ... MS132
AF09 ... AF30
AF09 ... AF30
Across-the-Line Starters
Reversing Starters
AF09 ... AF30
AF09 ... AF30
TF42
TF42
Starters Protected
by Thermal Overload Relays
Switching of 3-phase Cage Motors
Contactors
Thermal overload relays
1/92 | ABB
AC / DC Operated
Across-the-Line Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
Application
CE
Full voltage across-the-line starting is a simple and economic solution characterised by a high starting torque (1.9 to
2.1 times full-speed torque) and a starting current 5.5 to 7 times nominal current.
I /In C /C
n
7
6
I
5
I>
4
I = current
C = torque
In = nominal current
Cn = nominal torque
3
2
C
1
0
10
30
60
80
100
Description
You can easily assemble an across-the-line starter by using the BEA..-4 3-pole insulated connecting link. It is used
to electrically and mechanically connect MMS... manual motor starter and AF... contactor, AC or DC operated.
Starter selection is simple
SCCR, 600 V AC = 18 kA and 480 V AC = 50 kA.
MS132... + BEA..-4 + AF...
For other coordination, please contact your ABB local sales organization.
Main Technical Data
Rated operational voltage V max.
600 V
Rated insulation voltage Ui
according to IEC 60947-4-1
690 V
according to UL/CSA
600 V
Max. starting time
1.5 s
Switching frequency
≤ 15 starts/hour - 80 % max. load factor
≤ 30 starts/hour - 50 % max. load factor
Ambient air temperature close to the device
use with MS116 ≤ 55 °C
use with MS132 ≤ 60 °C
Degree of protection
IP 20
Standards
CSA C22.2 No. 14, UL508, IEC 60947-4-1 / EN 60947-4-1
Mounting positions
+30°
-30°
Pos. 2
Pos. 4
Pos. 3
Pos. 1
Pos. 1 ± 30°
Pos. 5
ABB | 1/93
Across-the-Line Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
I>
MS...
Manual motor starter
BEA...
Connecting link
AF...
Contactor
Wiring Diagrams
KM1:5/L3
33
43
44
5/L3
Us
34
3/L2
1/L1
43
44
5/L3
33
34
3/L2
1/L1
KM1:5/L3
33
Q1
34
Us
33
Q1
34
V
M
W
~
3-phase
1/94 | ABB
14
14
5/L3
6/T3
KM1
I
U
M
V
~
43
Q1
44
KM1
AC or DC local control
Us
N
43
Q1
44
KM1
A2
Us
N
A2
14
A1
A1
13
3/L2
4/T2
14
KM1
KM1:3/L2
U
13
13
6/T3
4/T2
2/T1
1/L1
2/T1
5/L3
6/T3
A1
O
O
I
13
3/L2
4/T2
6/T3
1/L1
2/T1
4/T2
I> I> I>
A2
KM1
I> I> I>
2/T1
Q1
KM1:3/L2
AC or DC remote control
Across-the-Line Starters Protected by MS132 Manual Motor Starters
AC-3
480 V
Short-circuit ratings, 30 kA at 480 V AC
Manual motor starters
Contactors
Accessories
I>
BEA..-4
cULus
Catalog number
(1)
480 V
Rated Rated
power current
HP
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
A(3)
0.2
0.3
0.6
0.65
0.8
1.0
1.4
1.8
2.6
3.4
4.8
7.6
11
14
21
27
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.0
MS132-1.6
MS132-1.6
MS132-2.5
MS132-4.0
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-25
MS132-32
Current setting
range
Magnetic tripping
current
Control voltage range
Uc min. ... Uc max.
A
0.16...0.25
A
2.44
V 50/60Hz
24...60
V DC
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
0.25...0.40
0.40...0.63
0.63...1.00
0.63...1.00
1.00...1.60
1.00...1.60
1.60...2.50
2.50...4.00
2.50...4.00
4.00...6.30
6.30...10.0
8.0...12.0
10.0...16.0
20.0...25.0
25.0...32.0
3.9
6.14
11.5
11.5
18.4
Catalog number
(2)
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
Allowed
current setting
A
0.25
1
1
1.6
24...60
20...60
AF09-30-10-11
1.6
29
100...250
20...60
AF09-30-10-13
AF09-30-10-11
2.5
100...250
100...250
AF09-30-10-13
50
79
150
180
240
375
480
24...60
20...60
AF09-30-10-11
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12-30-10-11
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16-30-10-11
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26-30-00-11
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30-30-00-11
100...250
100...250
AF30-30-00-13
BEA16-4
0.63
100...250
24...60
100...250
Catalog number
0.4
18.4
50
CA4-10
4
4
6.3
9
12
16
25
32
BEA38-4
+
CA4-10 (front)
or
CAL4-11 (side)
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 10 HP at 480 V - 18 kA
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
(3) These values of motor full-load current are to be used as guides only. For motor protection setting, always use those appearing on the motor nameplate.
ABB | 1/95
Across-the-Line Starters Protected by MS132 Manual Motor Starters
AC-3
600 V
Short-circuit ratings, 18 kA at 600 V AC
Manual motor starters
Contactors
Accessories
I>
BEA..-4
cULus
Catalog number
(1)
600 V
Rated Rated
power current
HP
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
A(3)
0.2
0.3
0.44
0.52
0.64
0.9
1.3
1.7
2.4
2.7
3.9
6.1
9
11
17
22
27
MS132-0.25
MS132-0.4
MS132-0.63
MS132-0.63
MS132-1.0
MS132-1.0
MS132-1.6
MS132-2.5
MS132-2.5
MS132-4.0
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-20
MS132-25
MS132-32
Current setting
range
Magnetic tripping
current
A
0.16...0.25
A
2.44
0.25...0.40
0.40...0.63
0.40...0.63
0.63...1.00
0.63...1.00
1.00...1.60
1.60...2.50
1.60...2.50
2.50...4.00
2.50...4.00
4.00 ...6.30
6.30...10.0
8.00...12.0
16.0...20.0
20.0...25.0
25.0...32.0
3.9
6.14
6.14
11.5
11.5
18.4
28.75
28.75
50
50
79
150
180
300
375
480
Control voltage range
Uc min. ... Uc max.
Catalog number
(2)
V 50/60Hz
24...60
V DC
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12-30-10-11
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16-30-10-11
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26-30-00-11
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30-30-00-11
100...250
100...250
AF30-30-00-13
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 10 HP at 600 V AC - 5 kA.
(2) For other control voltages, see «3-pole contactors - Ordering details» pages.
(3) These values of motor full-load current are to be used as guides only. For motor protection setting, always use those appearing on the motor nameplate.
1/96 | ABB
Allowed
current setting
A
0.25
CA4-10
Catalog number
BEA16-4
0.4
0.63
0.63
1
1
1.6
2.5
2.5
4
4
6.3
10
12
20
25
32
BEA38-4
+
CA4-10 (front)
or
CAL4-11 (side)
Reversing Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
Application
CE
Full voltage reversing starting is a simple and economic solution characterised by a high starting torque (1.9 to 2.1
times full-speed torque) and a starting current 5.5 to 7 times nominal current.
I /In C /C
n
7
6
I
5
I>
4
I = current
C = torque
In = nominal current
Cn = nominal torque
3
2
C
1
0
10
30
60
80
100
Description
You can easily assemble reversing starter thanks to our complete range of accessories:
–– BEA..-4 3-pole insulated connecting link: it is used to electrically and mechanically connect MS... manual motor
starter and AF contactor, AC or DC operated.
–– VEM4 mechanical and electrical interlock set for reversing starter in 90 mm width. It includes:
MS132... + BEA..-4 + BER..-4 + VEM4 + AF...
- VE4 electrical interlock block with A2-A2 connection
- VM4 mechanical interlock unit including 2 fixing clips.
–– BER..-4 connection set: it assures a safe and simple reversing connection between both contactor main
terminals.
Starter selection is simple
SCCR, 600 V AC = 18 kA and 480 V AC = 50 kA.
For other coordination, please contact your ABB local sales organization.
Main Technical Data
Rated operational voltage Ue max.
600 V
Rated insulation voltage Ui
according to IEC 60947-4-1
690 V
according to UL/CSA
600 V
Max. starting time
1.5 s
Switching frequency
≤ 15 starts/hour - 80 % max. load factor
Mounting positions
+30°
-30°
≤ 30 starts/hour - 50 % max. load factor
Ambient air temperature close to the device
Pos. 2
use with MS116 ≤ 55 °C
use with MS132 ≤ 60 °C
Pos. 4
Pos. 3
Pos. 1
Degree of protection
IP 20
Standards
IEC 60947-4-1 / EN 60947-4-1
Pos. 1 ± 30°
Pos. 5
ABB | 1/97
Reversing Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
MS...
Manual Motor Starter
Fixing clip
BEA...
Connecting link
VM4
Mechanical
interlock unit
AF...
Contactor
VE4
Electrical
interlock block
BER..-4
Connection set
A2
A2
Wiring Diagrams
5/L3
KM2:5/L3
33 Q1 34
33 Q1 34
Us
O
43
Us
33
3/L2
1/L1
KM2:5/L3
O
44
.3
3/L2
5/L3
4/T2
6/T3
.4
Us
N
43 Q1 44
KM1
A2
(1)
(3)
A1
AC or DC local control
V
W
M
~
3-phase
VEM4 = VM4+VE4 with A2-A2 connection
(1) (2)
(3)
1/98 | ABB
01
01
(2)
(2)
KM2:3/L2
U
.4
.4
01
01
(2)
KM2
I
(2)
.3
1/L1
2/T1
.4
6/T3
4/T2
2/T1
A2
.3
5/L3
3/L2
1/L1
A1
KM2
A2
KM1
KM1
KM2
II
.4
KM1
.3
.3
6/T3
4/T2
2/T1
I
.3
II
I> I> I>
.4
34
Q1
A2
KM2
KM1
Us
N
43 Q1 44
A2
(1)
(3)
KM2:3/L2
AC or DC remote control
A2
KM2
Reversing Starters Protected by MS132 Manual Motor Starters
AC-3
480 V
Short-circuit current ratings, 30 kA et 480 V AC
Manual motor starters
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
cULus
Catalog number
(1)
480 V
Rated Rated
power current
HP
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
A(3)
0.2
0.3
0.44
0.65
0.8
1.0
1.4
1.8
2.6
3.4
4.8
7.6
11
14
21
27
MS132-0.25
MS132-0.4
MS132-0.63
MS132-1.0
MS132-1.0
MS132-1.6
MS132-1.6
MS132-2.5
MS132-4.0
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-16
MS132-25
MS132-32
Current setting
range
Magnetic tripping
current
A
0.16...0.25
A
2.44
0.25...0.40
0.40...0.63
0.63...1.00
0.63...1.00
1.00...1.60
1.00...1.60
1.60...2.50
2.50...4.00
2.50...4.00
4.00...6.30
6.30...10.0
8.00...12.0
10.0...16.0
20.0...25.0
25.0...32.0
3.9
6.14
11.5
11.5
18.4
18.4
29
50
50
79
150
180
240
375
480
Control voltage range
Uc min. ... Uc max.
Catalog number
(2)
V 50/60Hz
24...60
V DC
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12-30-10-11
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16-30-10-11
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26-30-00-11
100...250
100...250
AF26-30-00-13
24...60
100...250
20...60
100...250
AF30-30-00-11
AF30-30-00-13
Allowed
current setting
A
0.25
0.4
CA4-10
Catalog number
BEA16-4
+
BER16-4
+
VEM4
0.63
1
1
1.6
1.6
2.5
4
4
6.3
10
12
16
25
32
BEA38-4
+
BER38-4
+
VEM4
+
2x CA4-10
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 10 HP at 480 V AC, 18 kA.
(2) For other control voltages, see “3-pole contactors - Ordering details” pages.
(3) These values of motor full-load ccurrentare to be used as guides only. For motor protection setting, always use those appearing on the motor nameplate.
ABB | 1/99
Reversing Starters Protected by MS132 Manual Motor Starters
AC-3
600 V
Short-circuit current ratings, 16 kA et 600 V AC
Manual motor starters
Contactors
Accessories
+
I>
BEA..-4
BER..-4
VEM4
cULus
Catalog number
(1)
600 V
Rated Rated
power current
HP
1/10
1/8
1/6
1/4
1/3
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
A(3)
0.2
0.3
0.44
0.52
0.64
0.9
1.3
1.7
2.4
2.7
3.9
6.1
9
11
17
22
27
MS132-0.25
MS132-0.4
MS132-0.63
MS132-0.63
MS132-1.0
MS132-1.0
MS132-1.6
MS132-2.5
MS132-2.5
MS132-4.0
MS132-4.0
MS132-6.3
MS132-10
MS132-12
MS132-20
MS132-25
MS132-32
Current setting
range
Magnetic tripping
current
Control voltage range
Uc min. ... Uc max.
A
0.16...0.25
A
2.44
V 50/60Hz
24...60
V DC
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF09-30-10-11
100...250
100...250
AF09-30-10-13
24...60
20...60
AF12-30-10-11
100...250
100...250
AF12-30-10-13
24...60
20...60
AF16-30-10-11
100...250
100...250
AF16-30-10-13
24...60
20...60
AF26-30-00-11
100...250
100...250
AF26-30-00-13
24...60
20...60
AF30-30-00-11
100...250
100...250
AF30-30-00-13
0.25...0.40
0.40...0.63
0.40...0.63
0.63...1.00
0.63...1.00
1.00...1.60
1.60...2.50
1.60...2.50
2.50...4.00
2.50...4.00
4.00 ...6.30
6.30...10.0
8.00...12.0
16.0...20.0
20.0...25.0
25.0...32.0
3.9
6.14
6.14
11.5
11.5
18.4
29
29
50
50
79
150
180
300
375
480
Catalog number List price
(2)
(1) MS116 manual motor starter can be selected according to the current setting range indicated on the coordination line, up to:
- 10 HP at 600 V AC, 5 kA.
(2) For other control voltages, see "3-pole contactors - Ordering details" pages.
(3) These values of motor full-load current are to be used as guides only. For motor protection setting, always use those appearing on the motor nameplate.
1/100 | ABB
Allowed
current setting
A
0.25
0.4
CA4-10
Catalog number
BEA16-4
+
BER16-4
+
VEM4
0.63
0.63
1
1
1.6
2.5
2.5
4
4
6.3
10
12
20
25
32
BEA38-4
+
BER38-4
+
VEM4
+
2x CA4-10
Direct-On-Line Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
Dimensions mm, inches
77 3.03"
17.5
0.69"
6
0.24"
186.8 7.35"
35 mm EN/IEC 60715
35
5
1.77"
1.38" 450.20"
5.5 0.22"
77 3.03"
MS132-12 ... MS132-32
+ BEA16-4
+ AF09, AF12, AF16
Ø 4.5 0.18"
M4 8-32UNC
26.25
1.03"
Ø 4.2 0.17"
M4 8-32UNC
80 3.15"
5
0.20"
35
1.38"
5
0.20"
5.5 0.22"
5
0.20"
5
0.20"
86 3.39"
5
0.20"
5
0.20"
5
0.20"
5
0.20"
26.25
1.03"
10 0.39"
26.25
1.03"
Ø 4.2 0.17"
M4 8-32UNC
5.5
0.22"
186.8 7.35"
45 1.77"
5.5 0.22"
45 1.77"
80 3.15"
10 0.39"
10
0.39"
Ø 4.5 0.18"
M4 8-32UNC
Ø 4.2 0.17"
M4 8-32UNC
45 1.77"
75
2.95"
45 1.77"
77 3.03"
6
0.24"
10 0.39"
17.5
0.69"
26.25
1.03"
5
0.20"
5.5 0.22"
10
0.39"
72.2 2.84"
6
0.24"
75
2.95"
35 mm EN/IEC 60715
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
75
2.95"
192 7.56"
81.1 3.19"
72.2 2.84"
186.8 7.35"
81.1 3.19"
192 7.56"
35
5
1.38"45 1.77"
0.20"
MS132-0.16 ... MS132-10
+ BEA16-4
+ AF09, AF12, AF16
MS116
+ BEA16-4
+ AF09, AF12, AF16
Ø4
M4
5.5
0.22"
5
0.20"
5
0.20"
5
0.20"
5
0.20"
5
0.20"
5.5 0.22"
17.5
0.69"
Ø 4.2 0.17"
M4 8-32UNC
Ø 4.2 0.17"
M4 8-32UNC
45 1.77"
72.2 2.84"
10
0.39"
192 7.56"
10 0.39"
186.8 7.35"
26.25
1.03"
81.1 3.19"
Ø 4.5 0.18"
M4 8-32UNC
5.5
0.22"
35 mm EN/IEC 60715
188 7.40"
186.8 7.35"
35 mm EN/IEC 60715
5.5
0.22"
10
0.39"
17.5
0.69"
6
0.24"
72.4 2.85"
45 1.77"
45 1.77"
81.3 3.20"
Ø 4.5 0.18"
M4 8-32UNC
10
0.39" 75
2.95"
70 2.76"
75
2.95"
188 7.40"
17.5
0.69"
6
0.24"
80.1 3.15"
35
1.38"
5
0.20"
86 3.39"
MS132-12 ... MS132-32
+ BEA38-4
+ AF26, AF30
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
ABB | 1/101
5
0.20"
35
1.38"
5
0.20"
Reversing Starters Protected by Manual Motor Starters
With AF Contactors - Open Type Version in Kit Form
AC-3
600 V
81.3 3.20"
Ø 4.5 0.18"
M4 8-32UNC
45 1.77"
10
0.39"
26.25
1.03"
5
0.20"
10
0.39"
70
2.76"
26.25
1.03"
186.8 7.35"
5.5
0.22"
35 mm EN/IEC 60715
186.8 7.35"
189.5 7.46"
10
0.39"
17.5
0.69"
72.4 2.85"
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
97 3.82"
Ø 4.5 0.18"
M4 8-32UNC
10
75
0.39"
2.95"
75
2.95"
189.5 7.46"
17.5
0.69"
6
0.24"
97 3.82"
80.1 3.15"
70 2.76"
6
0.24"
Dimensions mm, inches
Ø 4.2 0.17"
M4 8-32UNC
3,8
0.15"
5
0.20"
5
0.20"
5
0.20"
6
0.24"
17.5
Ø 4.5 0.18"
Ø 4.5 0.18"
0.69"
M4 8-32UNC
M4 8-32UNC
10
0.39"
3.8
0.15"
MS132-12 ... MS132-32
+ BEA16-4
+ AF09, AF12, AF16
Note: contactor lateral distance to grounded component 2 mm 0.08" min.
1/102 | ABB
5
0.20"
80
3.15"
90 3.54"
90 3.54"
5
0.20"
MS132-12 ... MS132-32
+ BEA38-4
+ AF26, AF30
5.5 0.22"
5.5 0.22"
70
2.76"
5
0.20"
5
0.20"
Ø 4.2 0.17"
Ø 4.2 0.17"
M4 8-32UNC
M4 8-32UNC
5
0.20"
90 3.54"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
5
0.20"
26.25 26.25
1.03" 1.03"
5
0.20"
10
0.39"
5
0.20"
10
0.39"
70
2.76"
45 1.77"
5.5
0.22"
5
0.20"
45 1.77"
35 mm EN/IEC 60715
26.25
1.03"
5.5
0.22"
10
0.39"
6
0.24"
186.8 7.35"
17.5
0.69"
72.2 2.84"
72.2 2.84"
70
2.76"
201.5 7.93"
186.8 7.35"
201.5 7.93"
10
0.39"
186.8 7.35"
81.1 3.19"
81.1 3.19"
5.5
0.22"
35 mm EN/IEC 60715
45 1.77"
114 4.49"
114 4.49"
Ø 4.5 0.18"
M4 8-32UNC
5
35 mm EN/IEC 60715
0.20"
17.5
0.69"
72.2 2.84"
75
2.95"
6
0.24"
81.1 3.19"
2.95"
75
80
3.15"
5
0.20"
MS132-0.16 ... MS132-10
+ BEA16-4
+ AF09, AF12, AF16
97 3.82"
193.5 7.62"
5
0.20"
90 3.54"
10 75
2.95"
0.39"
MS116
+ BEA16-4
+ AF09, AF12, AF16
35
1.38"
5
0.20"
90 3.54"
3.8
0.15"
5
0.20"
5
0.20"
Ø 4.2 0.17"
M4 8-32UNC
5
0.20"
5
0.20"
80
3.15"
80
3.15"
5
0.20"
5
0.20"
Download