LPS SERIES-Solar Power LPS12-115 (12V110AH) Specification 12V Nominal Voltage Nominal Capacity(100HR) 110.0AH Dimension Length Width Container Height Total Height (with Terminal) 306 168 208 230 2mm (12.05 inches) 2mm (6.61 inches) 2mm (8.19 inches) 2mm (9.06 inches) .D rn s b u ra te . e , or io n r in c in lo s g : e x p 0 OC , o 5 rn in re , Wa k o f fi e th e v R is t a b o a he on ot d is ass em b le , Approx 30.6Kg (67.5 Ibs) Approx Weight Terminal T14 Container Material ABS Rated Capacity 110.0 AH/1.10A 100.0 AH/5.0A 95.2 AH/9.52A 83.0 AH/16.6A 57.9 AH/57.9A (100hr ,1.80V/cell,250C/77 0F) (20hr ,1.80V/cell,250C/77 0F) Applications (10hr,1.80V/cell,250C/77 0F) (5hr,1.75V/cell,250C/77 0F) (1hr,1.60V/cell,250C/77 0F) Max. Discharge Current 1200A (5s) Internal Resistance Approx 4.9mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 Cycle Use Initial Charging Current less than30.0A.Voltage 0 0 0 14.4V~15.0V at 25 C(77 F)Temp. Coefficient -30mV/ C Standby Use No limit on Initial Charging Current Voltage 0 0 0 13.5V~13.8V at 25 C(77 F)Temp. Coefficient -20mV/ C Capacity affected by Temperature 40 o C (104 o F) 25 oC ( 77 o F) 0 oC ( 32 o F) Self Discharge Leoch LPS series batteries may be stored for up to 6 months at 25 0 C(77 0F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Green energy systems (solar, wind, hydro, etc) Solar power stations Telecommunications installations Measurement stations Pump systems Signal station Survey and Mapping system Emergency lighting Railway crossing Traffic lights Street lightening Lawn lamp Street signs SOS pillars Alarm installations Weekend cottage camping Caravans Boats or buoys 3 0C (77 5 0F ) 103% 100% 86% VdS t est ed 9 Germany Constant Current Discharge (Amperes) at 25 0C (77 0F ) F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 48h 100h 1.85V/cell 108.3 90.0 69.9 55.4 44.8 29.2 22.0 18.0 15.3 10.7 9.12 4.85 2.18 1.07 1.80V/cell 120.1 99.0 75.4 58.8 47.2 31.0 23.2 18.9 16.0 11.2 9.52 5.00 2.22 1.10 1.75V/cell 133.2 108.4 81.1 62.9 50.9 32.5 24.5 19.8 16.6 11.5 9.73 5.10 2.25 1.11 1.70V/cell 145.6 118.4 89.1 65.7 53.8 34.3 25.7 20.6 17.3 11.9 10.0 5.20 2.28 1.12 1.65V/cell 154.1 125.0 93.9 69.7 55.7 35.5 26.7 21.3 17.9 12.3 10.3 5.33 2.32 1.14 1.60V/cell 168.9 135.7 99.8 72.3 57.9 37.0 27.6 22.0 18.5 12.6 10.5 5.45 2.36 1.15 48h 100h Constant Power Discharge (Watts/cell) at 25 0C (77 0F ) F.V/Time 15min 20min 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 1.85V/cell 203.2 170.6 133.9 107.0 87.1 57.0 43.1 35.4 30.1 21.1 18.1 9.65 4.36 2.15 1.80V/cell 222.3 184.9 142.3 112.2 91.1 60.2 45.2 37.0 31.4 22.1 18.9 9.94 4.42 2.19 1.75V/cell 243.6 200.6 151.8 119.4 97.8 62.8 47.6 38.5 32.5 22.7 19.3 10.1 4.48 2.20 1.70V/cell 262.4 217.4 165.9 124.2 103.0 66.1 49.8 40.0 33.7 23.5 19.9 10.3 4.53 2.23 1.65V/cell 276.8 228.6 174.0 131.3 106.2 68.1 51.5 41.3 34.9 24.1 20.3 10.6 4.61 2.26 1.60V/cell 297.3 244.6 183.0 134.8 109.4 70.4 52.9 42.4 35.9 24.7 20.7 10.8 4.68 2.28 Specifications subject to change without notice. 1 Dimensions T14 Terminal Unit: mm [inches] 9 [0.354] 8.5 [0.335] 18 [0.709] 22 [0.866] 10 [0.394] 18 [0.709] 22 [0.866] 10 [0.394] 13 [0.512] 168 2 15.9 [0.626] 17.4 [0.685] 207 2 229 2 T14-2 Negative T14-1 Positive + + 305 2 Discharge Characteristics Effect of Temperature on Long Term Float Life 2.16 6.50 13.0 2.00 6.00 12.0 1.84 5.50 11.0 1.68 5.00 10.0 Temperature:25 0C 0.1C 0.0525C 0.02326C 0.0115C 0.25C 1.77C 1.52 4.50 9.00 1.36 4.00 8.00 2 4 6 1.04C 15 20 8 40 0.2 0.3 0.4 0.5 0.1 0.608C 60 100 1 2 200 400 600 3 4 5 1200 2000 10 20 3000 6000 (Min) 48 100 (Hours) 16 12 10 8 Life expectancy(year) Terminal Voltage(V) 6V 12V 2V Battery Battery Battery V V V Charging voltage 2.25V/cell 6 4 1 0 30 86 20 68 0 C F O Float Charging at Characteristics Self-Discharge Different Temperatures Cycle Service Life 100 Extracted Capcity in(%) 50 122 Battery temperature Discharge Time 100 80 70 75 60 50 40 50 30 20 %Rated Capacity Available 90 40 104 30 86 25 0 500 1000 1500 2000 2500 3000 0 2.60 2.50 Max.charge voltage B 2.45 Standard charge 2.35 C 2.30 6 9 12 15 18 21 24 27 A With switch regulator (two-step controller) charge on curve max.charge voltage for max.2 hrs/day then switch over to continous charge B Standard charge without switching C Boost charge (Equalizing charge with external generator) charge on curve continous charge for max. 5 hrs/month, then switch over to curve Standard charge Continous charge 2.40 3 Charge Mode A 2.55 8 46 20 68 Storage Time(months) 3500 Number of Cycles Charging in V per cell 40 104 2.25 2.20 -20 -10 0 +10 +20 +30 +40 +50 Temperature(0C) Sales Office China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Nanshan,Shenzhen, China. 518052 Tel:+ 86-755-86036060 (100 lines) Fax: +86-755-26067269 E-mail:export@leoch.com Http://www.leoch.com Add: Workshop C, 33/F, TML Tower, No. 3 Hoi Shing Road, Tsuen Wan, New Territories, Hong Kong Tel: +852 35786666 Fax: +852 21170016 E-mail: sales.hk@leoch.com Add: No. 1 Tech Park Crescent, Singapore 638131 Tel: +65 68416629 Fax: +65 68443210 Email sales.sg@Leoch.com Add: 19751 Descartes, Unit A, Foothill Ranch, CA 92610, USA Tel: 949-588-5853 Fax: 949-588-5966 E-mail: sales@leoch.us Http://www.leoch.com Add: 9B Wheatstone Court. Waterwells Business Park, Gloucester, GL2-2AQ, UK United Kingdom Tel: +44(0) 1452 729428 / 1452 729696 Fax: +44 (0)1452-690125 E-mail: Sales.Europe@leoch.com 2 Publication No.:LB-LCP-06-14