LPS SERIES-Solar Power

advertisement
LPS SERIES-Solar Power
LPS12-115 (12V110AH)
Specification
12V
Nominal Voltage
Nominal Capacity(100HR)
110.0AH
Dimension
Length
Width
Container Height
Total Height (with Terminal)
305
168
207
229
3mm (12.01 inches)
2mm (6.61 inches)
3mm (8.15 inches)
3mm (9.01 inches)
.D
rn s
b u ra te .
e
, or
io n r in c in
lo s
g : e x p 0 OC , o
5
rn in re ,
Wa k o f fi e th e
v
R is t a b o
a
he
on
ot
d is
ass
em
b le
,
Approx 31.5Kg (69.5 Ibs)
Approx Weight
Terminal
T14 / T6
Container Material
ABS
Rated Capacity
110.0 AH/1.10A
100.0 AH/5.0A
95.2 AH/9.52A
83.0 AH/16.6A
57.9 AH/57.9A
(100hr ,1.80V/cell,250C/77 0F)
(20hr ,1.80V/cell,250C/77 0F)
Applications
(10hr,1.80V/cell,250C/77 0F)
(5hr,1.75V/cell,250C/77 0F)
(1hr,1.60V/cell,250C/77 0F)
Max. Discharge Current
1200A (5s)
Internal Resistance
Approx 4.9mÙ
Operating Temp.Range
Discharge : -15 500C (5 1220F)
Charge
: 0 400C (32 1040F )
Storage : -15 400C (5 1040F)
Nominal Operating Temp. Range
25
Cycle Use
Initial Charging Current less than30.0A.Voltage
14.4V~15.0V at 25 0 C(77 0 F)Temp. Coefficient -30mV/ 0C
Standby Use
No limit on Initial Charging Current Voltage
13.5V~13.8V at 25 0 C(77 0 F)Temp. Coefficient -20mV/ 0C
Capacity affected by
Temperature
40 o C (104 o F)
25 oC ( 77 o F)
0 oC
( 32 o F)
Self Discharge
Leoch LPS series batteries may be stored for up to 6 months
at 25 0 C(77 0F) and then a freshening charge is required.
For higher temperatures the time interval will be shorter.
Green energy systems (solar, wind,
hydro, etc)
Solar power stations
Telecommunications installations
Measurement stations
Pump systems
Signal station
Survey and Mapping system
Emergency lighting
Railway crossing
Traffic lights
Street lightening
Lawn lamp
Street signs
SOS pillars
Alarm installations
Weekend cottage camping
Caravans
Boats or buoys
3 0C (77 5 0F )
103%
100%
86%
VdS
t est ed
9
0
Germany
0
Constant Current Discharge (Amperes) at 25 C (77 F )
F.V/Time
15min
20min
30min
45min
1h
2h
3h
4h
5h
8h
10h
20h
48h
100h
1.85V/cell
108.3
90.0
69.9
55.4
44.8
29.2
22.0
18.0
15.3
10.7
9.12
4.85
2.18
1.07
1.80V/cell
120.1
99.0
75.4
58.8
47.2
31.0
23.2
18.9
16.0
11.2
9.52
5.00
2.22
1.10
1.75V/cell
133.2
108.4
81.1
62.9
50.9
32.5
24.5
19.8
16.6
11.5
9.73
5.10
2.25
1.11
1.70V/cell
145.6
118.4
89.1
65.7
53.8
34.3
25.7
20.6
17.3
11.9
10.0
5.20
2.28
1.12
1.65V/cell
154.1
125.0
93.9
69.7
55.7
35.5
26.7
21.3
17.9
12.3
10.3
5.33
2.32
1.14
1.60V/cell
168.9
135.7
99.8
72.3
57.9
37.0
27.6
22.0
18.5
12.6
10.5
5.45
2.36
1.15
Constant Power Discharge (Watts/cell) at 25 0C (77 0F )
F.V/Time
15min
20min
30min
45min
1h
2h
3h
4h
5h
8h
10h
20h
48h
100h
1.85V/cell
203.2
170.6
133.9
107.0
87.1
57.0
43.1
35.4
30.1
21.1
18.1
9.65
4.36
2.15
1.80V/cell
222.3
184.9
142.3
112.2
91.1
60.2
45.2
37.0
31.4
22.1
18.9
9.94
4.42
2.19
1.75V/cell
243.6
200.6
151.8
119.4
97.8
62.8
47.6
38.5
32.5
22.7
19.3
10.1
4.48
2.20
1.70V/cell
262.4
217.4
165.9
124.2
103.0
66.1
49.8
40.0
33.7
23.5
19.9
10.3
4.53
2.23
1.65V/cell
276.8
228.6
174.0
131.3
106.2
68.1
51.5
41.3
34.9
24.1
20.3
10.6
4.61
2.26
1.60V/cell
297.3
244.6
183.0
134.8
109.4
70.4
52.9
42.4
35.9
24.7
20.7
10.8
4.68
2.28
1
Dimensions
T14 Terminal
Unit: mm [inches]
9 [0.354]
8.5 [0.335]
18 [0.709]
22 [0.866]
10 [0.394]
18 [0.709]
22 [0.866]
10 [0.394]
13 [0.512]
168 2
15.9 [0.626]
17.4 [0.685]
207 2
229 2
T14-2 Negative
T14-1 Positive
+
+
305 2
Discharge Characteristics
Effect of Temperature on Long Term Float Life
2.16
6.50
13.0
2.00
6.00
12.0
1.84
5.50
11.0
1.68
5.00
10.0
Temperature:25 0C
0.1C
0.0525C
0.02326C
0.0115C
0.25C
1.77C
1.52
4.50
9.00
1.36
4.00
8.00
2
4
6
8
1.04C
15 20
40
0.2 0.3 0.4 0.5
0.1
0.608C
60
100
1
2
200
400 600
3 4 5
1200 2000
10
20
3000
6000 (Min)
48
100 (Hours)
16
12
10
8
Life expectancy(year)
Terminal Voltage(V)
2V
6V
12V
Battery Battery Battery
V
V
V
Charging voltage
2.25V/cell
6
4
1
0
20
68
30
86
0
C
F
O
Float Charging at
Characteristics
Self-Discharge
Different Temperatures
Cycle Service Life
100
Extracted Capcity in(%)
50
122
Battery temperature
Discharge Time
100
80
70
75
60
50
40
50
30
20
%Rated Capacity Available
90
40
104
30
86
25
0
500
1000
1500
2000
2500 3000
0
2.60
2.50
Max.charge voltage
B
2.45
Standard charge
2.35
C
2.30
6
9
12
15
18
21
24
27
A
With switch regulator (two-step controller) charge on curve max.charge voltage for
max.2 hrs/day then switch over to continous charge
B
Standard charge without switching
C
Boost charge (Equalizing charge with external generator) charge on curve continous
charge for max. 5 hrs/month, then switch over to curve Standard charge
Continous charge
2.40
3
Charge Mode
A
2.55
8
46
20
68
Storage Time(months)
3500
Number of Cycles
Charging in V per cell
40
104
2.25
2.20
-20
-10
0
+10
+20
+30
+40
+50
Temperature(0C)
Sales Office
China sales office:
North America sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Add: 19751 Descartes, Unit A,
Nanshan,Shenzhen, China. 518052
Tel:+8 6-755-86036060 (100 lines)
Foothill Ranch, CA 92610, USA
Tel: 949-588-5853
Europe sales office:
Singapore sales office:
HongKong sales office:
Add: 9B Wheatstone Park, Waterwells
Add: No.53,Ubi Avenue 1, #03-21 Paya
Add: Unit 3910,39/F,Cable TV Tower,No.9
Business Park, Gloucester, GL2 2AQ. UK.
Ubi Industrial Park, Singapore 408934
Hoi Shing Road,Tsuen Wan, NT.H.K
Tel: +44(0) 01452 729428
Tel:+ 65 6841 6629
Tel: +852 3578 6666
E -mail: sales.sg@leoch.com
E-mail: sales.hk@leoch.com
Fax: +86-755-26067269
Fax: 949-588-5966
Fax: +44 (0)1452-690125
E-mail:export@leoch.com
E-mail: sales@leoch.us
E-mail: Sales.Europe@leoch.com
Http://www.leoch.com
Http://www.leoch.us
2
Download