LPX SERIES-High Rate / UPS LPX2-600 (2V600AH) Specification Nominal Voltage 2V Nominal Capacity(8HR) 600.0AH Dimension Length Width Container Height Total Height (with Terminal) 300 2mm (11.81 inches) 175 2mm ( 6.89 inches) 330 2mm (12.99 inches) 350 2mm (13.78 inches) Approx 36.5 kg (80.5lbs) Approx Weight Terminal T11 Container Material ABS Rated Capacity 630.0 AH/63.0A 600.0 AH/75.0A 534.5 AH/106.9A 468.9 AH/156.3A 375.0 AH/375.0A Max. Discharge Current 4800A (5s) Internal Resistance Approx 0.55mÙ Operating Temp.Range Discharge : -15 500C (5 1220F) Charge : 0 400C (32 1040F ) Storage : -15 400C (5 1040F) Nominal Operating Temp. Range 25 (10hr ,1.80V/cell,250C/770F) (8hr,1.75V/cell,250C/770F) (5hr,1.75V/cell,250C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F) Application Applications UPS (High rate) High power backup supply Emergency power supply 30C (77 50F ) Starting system Initial Charging Current less than 180.0A.Voltage Cycle Use Power tools 2.4V~2.5V at 250 C(770 F)Temp. Coefficient -5mV/0C Emergency lighting No limit on Initial Charging Current Voltage Standby Use Electric starting 2.25V~2.3V at 250 C(770 F)Temp. Coefficient -3mV/0C 103% 40o C (104o F) o o 100% 25 C ( 77 F ) o o 86% 0 C ( 32 F ) Leoch LPX series batteries may be stored for up to 6 months at 250 C(770F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Capacity affected by Temperature Self Discharge VdS t est ed 9 0 Germany 0 Constant Current Discharge (Amperes) at 25 C (77 F ) F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 729.1 642.5 564.7 500.0 417.8 339.4 276.9 185.6 141.9 114.4 97.8 86.3 70.0 59.7 31.6 1.80V/cell 887.5 751.9 643.4 560.3 459.1 365.0 295.0 195.3 153.8 118.4 101.9 89.7 73.1 63.0 32.8 1.75V/cell \ 861.6 728.1 620.9 499.4 395.0 317.5 207.2 156.3 125.0 106.9 94.1 75.0 63.8 33.1 1.70V/cell \ \ 804.7 682.8 542.5 421.9 336.3 218.8 163.1 130.0 111.3 97.5 77.5 65.3 34.1 1.65V/cell \ \ 856.3 721.9 568.4 438.8 349.4 225.9 168.4 134.1 114.4 99.1 79.1 66.3 34.4 1.60V/cell \ \ \ 804.7 621.9 474.4 375.0 237.2 175.3 139.7 119.7 103.4 81.9 68.4 35.6 Constant Power Discharge (Watts) at 25 0C (77 0F ) 5min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1059.4 947.5 800.6 655.6 537.2 362.2 278.1 224.7 192.8 170.3 138.8 118.8 63.1 1191.3 1046.3 866.3 699.7 569.1 378.8 299.7 231.3 199.7 176.6 144.7 124.8 65.3 10min 15min 1.85V/cell 1340.6 1193.1 1.80V/cell 1614.4 1380.0 F.V/Time 1.75V/cell \ 1556.3 1331.3 1148.4 934.4 750.3 609.7 400.3 303.1 243.1 208.8 184.7 148.1 126.6 65.9 1.70V/cell \ \ 1450.9 1253.4 1009.7 798.4 643.1 421.6 315.9 252.8 216.9 190.9 152.8 129.4 67.5 1.65V/cell \ \ 1531.9 1315.0 1049.4 822.5 663.8 433.1 324.7 259.4 222.2 193.8 155.3 131.3 68.4 1.60V/cell \ \ \ 1450.3 1140.0 885.0 708.8 452.5 336.9 269.4 231.9 201.6 160.6 135.3 70.3 1 Dimensions T11 Terminal Unit: mm [inches] 20 [0.787] 350 2 337 2 330 2 119 2 175 2 7 [0.276] M8 [0.315] 200 2 300 2 Discharge Characteristics Float Charging Characteristics 2V Battery V 2.18 Charge Volume 0 Temperature:25C Charging Current (A) % Charging Voltage 0 0.1CA-2.25V/cell temperature25C (V/cell) Terminal Voltage(V) 2.00 120 0.10C 2.4 100 0.08C 2.3 80 0.06C 2.2 60 0.04C 2.1 40 0.02C 2.0 20 0C Charged Volume 1.83 0.6C 0.4C 1.67 0.106C 0.056C 0.21C Charge Voltage (Constant 2.25V/cell) 1C After 50% Discharge 2C 1.5 1.33 3C After 100% Discharge Charging Current 1 2 4 6 810 S 20 40 60 2 4 6 8 10 min 20 40 60 2 4 6 8 10 H 20 0 Discharge Time Capacity (%) 8 12 16 20 24 28 32 36 Charging Time(Hours) Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 120 12 100 10 8 5C 0.1 2 C 0.2 1 80 4 Charging voltage : 2.25V/cell 5 3 60 1.0C 40 2 2. 0 C 20 0 -20 0 -10 0 10 30 20 40 20 68 50 Temperature( 0C ) 40 104 50 0C 122 OF Battery temperature 100 100C Remaining Capacity(%) 30 86 Self Discharge Characteristics A 80 250C 60 B 300C A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 0 40 C 40 C 20 0 0 2 4 6 8 10 Storage Time(Months) 12 Add: 12C Wheatstone Park, Waterwells Business Park, Gloucester, GL2 2AQ. UK. Tel: +44(0) 1452 751016 Fax: +44 (0)1452-690125 E-mail: Sales.Europe@leoch.com 2