Npower™ 3-Phase UPS: 30 to 80 kVA, 208 or 480VAC, 60 Hz • Unmatched heritage of reliability and availability • Smallest system footprint • Excellent efficiency with non-linear loads and partial loads • Outstanding dynamic response • All-digital ActiveStar™ controls and graphical user interface The Npower is a true double-conversion UPS, the result of an international design collaboration and more than a decade of advanced research. The rugged power train and advanced ActiveStar™ controls were subjected to computer simulations and accelerated life testing to ensure reliable performance in every type of electrical environment. Even the physical packaging is uniquely efficient, to make fully configured systems more compact than its competitors. Best of all, it’s a Liebert product – designed to give the same million-hour critical bus MTBF as other Liebert UPS products. OUTPUT Voltage: 208 or 480 VAC, 3-phase, 4-wire plus ground Voltage Adjustment Range: ±5% Voltage Regulation: ±0.5% for balanced load ±1.0% for 100% unbalanced load Dynamic Regulation: ± 2.5% deviation for 100% load step. ±1% for loss or return of AC input Transient Response Time: Recover to ±1% of steady state within 1 cycle Voltage Distortion: For linear loads, 1% THD. Less than 2.5% THD for 100% nonlinear loads without kVA/kW derating Phasing Balance: 120° ±0.5° for balanced load. 120° ±1° for 100% unbalanced load Frequency Regulation: ±0.1% Load Power Factor Range: 1.0 to 0.7 lagging without derating Overload: 125% of full load for ten minutes. 150% for one minute, with true sinusoidal waveform STANDARDS ETL Listed to UL 1778 UPS standards, and CSA certified. Some configurations are certified to UL 924 standards for emergency lighting. GENERAL SPECIFICATIONS INPUT Voltage: 208 or 480 VAC, 60 Hz 3-phase, 3-or 4-wire plus ground Voltage Range: +10, -15% (no battery discharge at 20%) Frequency Range: 60 Hz, ± 5 Current Distortion: 10% maximum reflected THD at full load with included input filter. Current Limit: 115% of full load input current Current Walk-in: 20 seconds to full load Power Factor: 0.95 lagging minimum at full load, with included input filter Surge Protection: Sustains input surges without damage, per criteria listed in ANSI C62.41-1980 (IEEE 587) ENVIRONMENTAL Operating Temperature: 0° to 40°C (UPS), 20° to 30°C (battery) Non-Operating Temperature: -20°C to 70°C Relative Humidity: 0-95% non-condensing Operating Altitude: Up to 6,600 feet (2000 meters) without derating Acoustical Noise: Less than 65 dBA typical, measured 1 meter from the unit Matching Battery Packs Model 30 1FJ 1HJ 1LJ 1MH 1PH 1RH 1UH 1WH 11 21 28 34 50 66 74 109 Battery Time in Minutes /UPS kVA 40 50 65 7 14 19 23 36 46 52 77 10 14 18 27 35 39 60 5 8 13 20 25 30 41 Weight (lb) 30-50 kVA 1,210 Weight (lb) 65-80 kVA 1,320 Maintenance Bypass Cabinets Model Q Dimensions (In.) (WxDxH) 31.7x32.5x71 80 Dimensions (In.) (WxDxH) Weight (lb) 5 9 15 19 22 33 25x32.5x71 25x32.5x71 25x32.5x71 25x32.5x71 25x32.5x71 49x32.5x71 49x32.5x71 49x32.5x71 1,600 1,800 2,350 2,470 3,000 3,900 4,250 5,450 Slim-Line Distribution Cabinet Dimensions (In.) (WxDxH 10x32.5x71 Weight (lb) 250 Site Planning Data UPS Rating KVA KW 30 30 30 40 40 40 50 50 50 65 65 65 80 80 80 24 24 24 32 32 32 40 40 40 52 52 52 64 64 64 Npower™ 3-Phase UPS: 30-80 kVA, 208 or 480 VAC, 60 Hz AC Input w/Filter Voltage Current (Amps) Rec. Input Output Nom. Max. OCPD 208 480 480 208 480 480 208 480 480 208 480 480 208 480 480 208 208 480 208 208 480 208 208 480 208 208 480 208 208 480 80 33 33 106 44 44 133 55 55 171 70 70 210 87 87 1 99 41 41 133 55 55 166 69 69 213 88 88 262 108 108 2,3,8,12 125 50 50 175 70 70 200 100 100 300 125 125 350 150 150 6,14 Nom. VDC 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 4 Battery Battery Max. KW Discharge 26 26 26 34 34 34 43 43 43 55 55 55 68 68 68 AC Output Current Nom OCPD 66A 83 66A 83 66A 36 88A 111 88A 111 88A 48 109A 139 109A 139 109A 60 141A 180 141A 180 141A 78 174A 222 174A 222 174A 96 1,3,5,8,12 1,3,8,12 NOTES FOR TABLE: 1. Nominal (Nom) current is based on full rated output load. 2. Maximum (Max) current (125% of nominal) is short duration for battery recharge conditions. 3. UPS input and bypass cables must be run in separate conduit from output cables. 4. Nominal battery voltage is shown at 2.0 volts/cell per NEC 480-2. 5. Power cables from UPS DC link to batteries should be sized for a total maximum 2.0 volt line drop (measured at the UPS) at maximum discharge current. 6. Recommended AC input and AC output overcurrent protection represents 125% of nominal full load current (continuous) plus non-continuous loads per NEC 215. 7. Minimum-sized grounding conductors to be per NEC 250-122. Parity-sized ground conductors are recommended. Neutral conductors to be sized for full capacity per NEC 310-15(b)(4). References are per NEC 1999. 8. Wiring requirements: AC Input: 3-phase, 3-wire plus ground or 3-phase, 4-wire plus ground AC Output: 3-phase, 4-wire plus ground DC Input: 2-wire (positive and negative), plus ground 9. All wiring is to be in accordance with national and local electrical codes. 10. Minimum access clearance is 3 feet front and 1 foot above UPS. 11. Top or bottom cable entry through removable access plates. Punch plate to suit conduit size, then replace. 12. Control wiring and power wiring must be run in separate conduit. 13. Weights and dimensions shown do not include battery cabinet, Slim-Line distribution cabinet or other options. 14. OCPD=Overcurrent Protection Device. 125 125 50 150 150 60 175 175 80 225 225 100 300 300 125 6,14 Mechanical Data Dimensions (In.) (WxDxH) Weight (Lb) Floor Load (Lb/Sq.Ft) Heat Dissipation (BTU/Hr) Cooling Air (CFM) 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 31.7x32.5x71 39.4x32.5x71 39.4x32.5x71 39.4x32.5x71 39.4x32.5x71 39.4x32.5x71 39.4x32.5x71 13 2,200 2,100 1,900 2,200 2,100 1,900 2,200 2,100 1,900 2,700 2,500 2,300 2,700 2,500 2,300 13 307 294 265 307 294 265 307 294 265 304 284 262 304 284 262 8,500 7,500 7,500 11,000 10,000 10,000 14,000 12,000 12,000 18,000 15,000 15,000 22,000 18,000 18,000 720 720 720 720 720 720 720 720 720 960 960 960 960 960 960 ADDITIONAL NOTES: • • • If site configuration includes a back-up emergency generator, it is recommended that the engine generator set be properly sized and equipped for a UPS application. Generator options would typically include an isochronous governor (generator frequency regulation) and a UPS-compatible regulator (generator voltage regulation). Consult generator manufacturer for required generator options and sizing. If site configuration includes an automatic transfer switch, refer to the Liebert Power Line titled “Criteria for Application of Automatic Transfer Switches (ATS) with Uninterruptible Power Supply (UPS) Systems,” publication 91K-PLT-48-02. It is also recommended that the transfer switch be equipped with auxiliary contacts for UPS “on generator” current limit. Consult transfer switch manufacturer for required transfer switch options and sizing. If site configuration requires an external isolated maintenance bypass circuit, it should be noted that utility AC input may not be in phase with the UPS AC output. Consult Liebert sales representative or applications engineer. 2003 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Printed in the USA SL-24547 Revision 2 (02/2003) Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio, 43229 Telephone: 800-877-9222 Facsimile: 614-841-6022