Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated Medium-Voltage Switchgear Catalog HA 35.61 · 2011 Answers for energy. R-HA35-158.eps Application: Onshore wind park R-HA35-156.eps R-HA35-157.eps R-HA35-159.eps Application: Offshore wind park 2 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Contents Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated Medium-Voltage Switchgear Application Page Types, typical uses, ratings 4 and 5 Requirements Features, safety, technology 6 and 7 Technical data Electrical data Room planning Shipping data, classification 8 9 10 Dimensions Front views, sections, floor openings, fixing points 11 Product range Catalog HA 35.61 · 2011 Single-busbar panels 12 Design Basic panel design 13 Components Vacuum circuit-breaker Three-position switches Busbars Current transformers Panel connection Installation possibilities for cable connections and surge arresters Panel connection Indicating and measuring equipment Protection, control, measuring and monitoring equipment 14 and 15 16 and 17 18 19 20 21 and 22 22 23 to 26 27 Standards Standards, specifications, guidelines 28 and 29 The products and systems described in this catalog are manufactured and sold according to a certified management system (acc. to ISO 9001, ISO 14001 and BS OHSAS 18001). DNV Certificate No.: 92113-2011-AHSO-GER-TGA and Certificate No.: 87028-2010-AHSO-GER-TGA. Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 3 Application R-HA35-162.eps R-HA35-160.eps Types Disconnector panel 450 mm Circuit-breaker panel 600 mm 4 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Application Typical uses, ratings Fixed-mounted circuit-breaker switchgear NXPLUS C Wind is a factory-assembled, type-tested, metal-enclosed, metal-clad, SF6 -insulated switchgear for single-busbar applications for indoor installation. They are mainly used in wind turbines and in substations for connecting the wind turbines to the wind park network. Additionally, they can also be used in transformer and switching substations for other applications. Electrical data (maximum values) and dimensions Rated voltage kV 36 Rated frequency Hz 50 / 60 Rated short-duration power-frequency withstand voltage kV Rated lightning impulse withstand voltage kV 170 Rated peak withstand current kA 63 Rated short-circuit making current kA 63 Rated short-time withstand current 1s 3s kA kA 25 20 Rated short-circuit breaking current kA Rated normal current of the busbar A 1000 A 630 / 1000 Rated normal current of feeders Width 70 mm 25 450 / 600 Depth with pressure relief duct at the rear mm 1000 Height mm 1900 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 5 Requirements Features Safety Environmental independence Hermetically tight, welded switchgear vessels made of stainless steel as well as single-pole solid insulation make the parts of the primary circuit under high voltage of NXPLUS C Wind switchgear • Insensitive to certain aggressive ambient conditions, such as: – Saline air – Air humidity – Dust – Condensation • Tight to ingress of foreign objects, such as: – Dust – Pollution – Small animals – Humidity • Independent of the site altitude. Personal safety • Safe-to-touch and hermetically sealed primary enclosure • Cable terminations and busbars are surrounded by earthed layers • All high-voltage parts including the cable terminations and busbars are metal enclosed • Capacitive voltage detecting system to verify safe isolation from supply • Operating mechanisms and auxiliary switches safely accessible outside the primary enclosure (switchgear vessel) • Due to the system design, operation is only possible with closed switchgear enclosure • Standard degree of protection IP 65 for all high-voltage parts of the primary circuit, IP 3XD for the switchgear enclosure according to IEC 60529 and VDE 0470-1 • High resistance to internal arcs by logical mechanical interlocks and tested switchgear enclosure • Panels tested for resistance to internal faults up to 25 kA • Logical mechanical interlocks prevent maloperation • Make-proof earthing by means of the vacuum circuit-breaker. Compact design Thanks to the use of SF6 insulation, compact dimensions are possible. This is the basic prerequisite for application in wind turbines. For installation or removal, it must be possible to bring the switchgear in through the door of the wind turbine. Maintenance-free design Switchgear vessels designed as sealed pressure systems, maintenance-free switching devices and enclosed cable plugs ensure: • Maximum supply reliability • Personnel safety • Sealed-for-life design according to IEC 62271-200 (sealed pressure system) • Installation, operation, extension and replacement without SF6 gas work • Reduced operating costs • Cost-efficient investment • No maintenance cycles. Innovation The use of digital secondary systems and combined protection and control devices ensures: • Clear integration in process control systems • Flexible and highly simplified adaptation to new system conditions and thus to cost-efficient operation. Service life Under normal operating conditions, the expected service life of the gas-insulated switchgear NXPLUS C Wind is at least 35 years, probably 40 to 50 years, taking the tightness of the hermetically welded switchgear vessel into account. The service life is limited by the maximum number of operating cycles of the switching devices installed: • For circuit-breakers according to the endurance class defined in IEC 62271-100 • For three-position disconnectors and earthing switches according to the endurance class defined in IEC 62271-102 • For three-position switch-disconnectors and earthing switches according to the endurance class defined in IEC 60265-1. Security of operation • Hermetically sealed primary enclosure independent of environmental effects (pollution, humidity and small animals) • Maintenance-free in an indoor environment (IEC 62271-1 and VDE 0671-1) • Operating mechanisms of switching devices accessible outside the primary enclosure (switchgear vessel) • Current transformers as ring-core current transformers mounted outside the SF6 switchgear vessel • Complete switchgear interlocking system with logical mechanical interlocks • Welded switchgear vessels, sealed for life • Minimum fire load • Type and routine-tested • Standardized, NC production processes • Quality assurance in accordance with DIN EN ISO 9001 • More than 500,000 switchgear panels of Siemens in operation worldwide for many years • Option: Aseismic design. Reliability • Type and routine-tested • Standardized, NC production processes • Quality assurance in accordance with DIN EN ISO 9001 • More than 500,000 switchgear panels of Siemens in operation worldwide for many years. 6 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Requirements Technology General • 3-pole enclosure of the primary part consisting of a switchgear vessel made of stainless steel • Insulating gas SF6 • Three-position switch as busbar disconnector and feeder earthing switch • Make-proof earthing by means of the vacuum circuit-breaker • Compact dimensions due to SF6 insulation • Hermetically tight, welded switchgear vessel made of stainless steel • 1-pole, solid-insulated, screened busbars, plug-in type • Cable connection with outside-cone plug-in system • Wall-standing or free-standing arrangement • Cable connection access from front • Installation and extension of existing switchgear at both ends without gas work and without modification of existing panels. Interlocks • According to IEC 62271-200 and VDE 0671-200 • Logical mechanical interlocks prevent maloperation • Three-position disconnector can only be operated with circuit-breaker in OPEN position • Circuit-breaker can only be operated with three-position switch in end position and operating lever removed • Three-position disconnector interlocked against the circuitbreaker in circuit-breaker panels • Feeder locking device • Locking device for three-position switch • O ption: Cable compartment cover interlocked against the three-position switch (circuit-breaker panel, disconnector panel, ring-main panel) • Option: Electromagnetic interlocks • O ption: Actuating openings can be padlocked • Option: “Feeder earthed“ locking device. Modular design • Panel replacement possible without SF6 gas work • Low-voltage compartment removable, plug-in bus wires. Instrument transformers • Current transformers not subjected to dielectric stress • Easy replacement of current transformers designed as ring-core transformers. Vacuum circuit-breaker • Maintenance-free under normal ambient conditions according to IEC 62271-1 and VDE 0671-1 • No relubrication or readjustment • Up to 2000 operating cycles • Vacuum-tight for life. Secondary systems • Customary protection, measuring and control equipment • O ption: Numerical multifunction protection relay with integrated protection, control, communication, operating and monitoring functions • Can be integrated in process control systems. Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 7 Technical data Electrical data, filling pressure, temperature for single-busbar switchgear Common electrical data, filling pressure and temperature Rated insulation level Rated voltage Ur kV 36 Rated short-duration power-frequency withstand voltage Ud: – phase-to-phase, phase-to-earth, open contact gap – across the isolating distance kV kV 70 80 Rated lightning impulse withstand voltage Up: – phase-to-phase, phase-to-earth, open contact gap – across the isolating distance kV kV 170 180 Hz 50 / 60 3) Rated frequency fr Rated normal current Ir 1) for the busbar up to A 1000 Rated filling level pre 2) 150 kPa (absolute) at 20 °C Minimum functional level pme 2) 130 kPa (absolute) at 20 °C Ambient air temperature –25°C to +55° C Data of the switchgear panels Circuit-breaker panel 630 A Rated normal current Ir 1) A up to kA for switchgear with tk = 3 s up to kA 20 –1 up to kA 50 63 Rated short-circuit making current Ima up to kA 50 63 Rated short-circuit breaking current Isc up to kA 20 25 Rated peak withstand current Ip Electrical endurance of vacuum circuit-breakers Disconnector panel 630 A 1000 A 25 2000 operating cycles at rated short-circuit breaking current 20 breaking operations Rated normal current Ir 1) Rated short-time withstand current Ik 20 at rated normal current A A 630 1000 for switchgear with tk = 1 s up to kA for switchgear with tk = 3 s up to kA 20 –1 up to kA 50 63 Rated peak withstand current Ip Ring-main panel 3) 630 for switchgear with tk = 1 s Rated short-time withstand current Ik Rated normal current Ir 1) for feeder Rated short-time withstand current Ik for switchgear with tk = 1 s up to kA for switchgear with tk = 3 s A 20 630 20 up to kA 20 Rated peak withstand current Ip up to kA 50 Rated short-circuit making current Ima up to kA 50 1) The rated normal currents apply to ambient air temperatures of max. 40 °C. The 24-hour mean value is max. 35 °C (according to IEC 62271-1 / VDE 0671-1) 2) Pressure values for SF6 -insulated switchgear vessels 3) Ring-main panels for 60 Hz on request 8 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 25 Technical data Room planning ³ 50 600 600 1000 450 Room height ≥ 2400 mm Wall-standing arrangement (top view) ³ 500 HA35-2763 eps 450 450 600 600 1000 Switchgear fixing • For floor openings and fi xing points of the switchgear, see page 11 • Foundations: – Steel girder construction – Steel-reinforced concrete with foundation rails, welded or bolted on. ³ 50** ³ 50** Door dimensions The door dimensions depend on the dimensions of the individual panels (see page 11). ³ 800* 450 Panel dimensions See page 11. ³ 50** ³ 50** * Depending on national requirements; for extension / panel replacement: Control aisle ≥ 1200 mm recommended ** Lateral wall distances on the left or on the right: ≥ 500 mm is recommended ³ 800* Room dimensions See opposite dimension drawings. Room planning for single-busbar switchgear HA35-2762 eps Switchgear installation • For single-busbar applications: – Wall-standing arrangement or – Free-standing arrangement. Free-standing arrangement (top view) Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 9 Technical data Shipping data, classification Transport NXPLUS C Wind switchgear is delivered in form of individual panels, or as a panel combination with a maximum width of 1500 mm. Please observe the following: • Transport facilities on site • Transport dimensions and transport weights • Size of door openings in building. Packing Place of destination inside Germany or other European countries • Means of transport: Rail and truck • Type of packing: – Panels on pallets – Open packing with PE protective foil. Place of destination overseas • Means of transport: Ship • Type of packing: – Panels on pallets – In closed crates with sealed upper and lower PE protective foil – With desiccant bags – With sealed wooden base – Max. storage time: 6 months. Transport dimensions, transport weights 1) Panel widths mm Transport dimensions Width × Height × Depth Transport weight with packing without packing mm × mm × mm approx. kg approx. kg NXPLUS C Wind transport inside Germany or to European countries 1 × 450 1100 × 2120 × 1450 500 400 1 × 600 1100 × 2120 × 1450 600 500 2 × 450 1450 × 2470 × 1450 1000 800 1 × 600 + 1 × 450 1450 × 2470 × 1450 1100 900 2 × 600 1776 × 2470 × 1400 1200 1000 1 × 600 + 2 × 450 1776 × 2470 × 1400 1600 1300 3 × 450 1776 × 2470 × 1400 1500 1200 NXPLUS C Wind transport to overseas 1 × 450 1130 × 2650 × 1450 500 400 1 × 600 1130 × 2650 × 1450 600 500 2 × 450 1450 × 2650 × 1480 1000 800 1 × 600 + 1 × 450 1450 × 2650 × 1480 1100 900 2 × 600 1776 × 2410 × 1426 1200 1000 1 × 600 + 2 × 450 1776 × 2410 × 1426 1600 1300 3 × 450 1776 × 2410 × 1426 1500 1200 Classification of NXPLUS C switchgear according to IEC 62271-200 Design and construction Partition class PM (metallic partition) Loss of service continuity category LSC 2B Accessibility to compartments (enclosure) Busbar compartment Switching device compartment Low-voltage compartment Cable compartment Tool-based Non-accessible Tool-based Tool-based Internal arc classification Designation of the internal arc classification IAC IAC class for: Wall-standing arrangement Free-standing arrangement Type of accessibility A –F –L –R IAC A FL 25 kA, 1 s IAC A FLR 25 kA, 1 s Switchgear in closed electrical service location, access “for authorized personnel only“ according to IEC 62271-200 Front Lateral Rear (for free-standing arrangement) Arc test current 25 kA Test duration 1s 1) Average values depending on the degree to which panels are equipped 10 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Dimensions Front views, sections, floor openings, fixing points for single-busbar switchgear Circuit-breaker panel Disconnector panel 110 110 570 600 325 450 100 1000 4 3 2 600 30 3 595 860 1000 315 25 25 100 1 46 180 3 30 180 2 465 3 46 185 30 30 ³ 50 4 ³ 50 1000 730 1000 100 860 1578 1900 HA35-2624c eps 500 HA35-2622b eps 1578 1900 325 570 815 110 110 1 100 450 Ring-main panel (switch-disconnector panel without HV HRC fuses) 570 1000 450 100 815 730 HA35-2767 eps 1578 1900 325 110 110 3 3 30 180 2 595 46 860 25 1000 185 30 ³ 50 4 1 100 450 1 Floor opening for control cables 2 Floor opening for high-voltage cables 3 Fixing hole for M8 / M10 4 Pressure relief duct Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 11 Product range Single-busbar panels Circuit-breaker panel Disconnector panel Three-position disconnector Three-position switch-disconnector or or or Current transformer 2) Capacitive voltage detecting system Surge arrester or limiter 630 A 630 A and 1000 A Cable connection with outside-cone plug (not included in the scope of supply) Ring-main panel HA35-2766 eps 1) or or 630 A 2) 1) Depending on the type of cable T-plug, three cables are possible 2) Depending on the type of cable T-plug, an additional surge arrester can be installed at the double cable connection 12 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 HA35-2775 eps HA35-2764 eps HA35-2765 eps Vacuum circuit-breaker 1) Design Basic panel design Insulating system • Switchgear vessel filled with SF6 gas • Features of SF6 gas: – Non-toxic – Odorless and colorless – Non-inflammable – Chemically neutral – Heavier than air – Electronegative (high-quality insulator) • Pressure of SF6 gas in the switchgear vessel (absolute values at 20 °C): – Rated filling level: 150 kPa – Design pressure: 180 kPa – Design temperature of the SF6 gas: 80 °C – Operating pressure of bursting disc: ≥ 300 kPa – Bursting pressure: ≥ 550 kPa – Gas leakage rate: < 0.1 % per year. Panel design • Factory-assembled, type-tested • Metal-enclosed, metal-clad • Hermetically tight, welded switchgear vessel made of stainless steel • 1-pole, solid-insulated, screened busbars, plug-in type • Maintenance-free • Degree of protection – IP 65 for all high-voltage parts of the primary circuit – IP 3XD for the switchgear enclosure • Vacuum circuit-breaker • Three-position disconnector for disconnecting and earthing by means of the circuit-breaker • Make-proof earthing by means of the vacuum circuit-breaker • Three-position switch-disconnector • Cable connection with outside-cone plug-in system according to DIN EN 50 181 • Wall-standing or free-standing arrangement • Installation and possible later extension of existing panels without gas work • Replacement of switchgear vessel without gas work • Replacement of instrument transformers without gas work, as they are located outside the gas compartments • Enclosure made of sendzimirgalvanized sheet steel, front cover, rear cover and end walls powdercoated in color “light basic” (SN 700) • Low-voltage compartment removable, plug-in bus wires • Lateral, metallic wiring ducts for control cables. Circuit-breaker panel (example) Front view Side view (cable connection from the front) Detail Z: 1 Low-voltage compartment 2 Multifunction protection relay 7SJ45 (example) 3 Position indicator for circuit-breaker 4 Actuating opening for charging the circuitbreaker springs 5 ON pushbutton for circuit-breaker 6 “Spring charged” indicator 7 Operations counter for circuit-breaker 8 Interrogation lever 9 Control gate and locking device for “disconnecting/earthing” functions of three-position switch 10 Position indicator for “disconnecting” function of three-position switch 11 Position indicator for “ready-to-earth” function of three-position switch 12 Actuating opening for “disconnecting” function of three-position switch 13 Actuating opening for “ready-to-earth” function of three-position switch 14 Ready-for-service indicator 15 Busbar, 1-pole, fully insulated, plug-in type, earthed on the outside 16 Capacitive voltage detecting system at the busbar 17 Switchgear vessel, hermetically welded, filled with SF6 gas 18 Three-position disconnector 19 OFF pushbutton for circuit-breaker 20 Feeder locking device (suitable for padlocking) 21 Circuit-breaker with vacuum interrupters 22 Capacitive voltage detecting system at the cable connection 23 Pressure relief duct 24 Cable compartment 25 Pressure relief (bursting disc) 26 Earthing busbar with earthing connection 27 Air guides for cable connection 28 Cable connection with cable T-plug 29 Feeder current transformer 30 Operating mechanism for circuit-breaker 31 Operating mechanism for three-position switch Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 13 Components Vacuum circuit-breaker Features • According to IEC 62271-100 and VDE 0671-100 (for standards, see page 28) • Application in hermetically welded switchgear vessel in conformity with the system • Climate-independent vacuum interrupter poles in the SF6 -filled switchgear vessel • Maintenance-free for indoor installation according to IEC 62271-1 and VDE 0671-1 • Individual secondary equipment • A metal bellows is used for gasketless separation of the SF6 insulation and the operating mechanism (already used with success for over 2 million vacuum interrupters). Vacuum circuit-breaker 1 2 3 4 5 6 7 Trip-free mechanism The vacuum circuit-breaker is fitted with a trip-free mechanism according to IEC 62271 and VDE 0671. Operating mechanism functions • Manual spring-operated mechanism In the case of manual spring-operated mechanism, the closing spring is charged by means of a hand crank. When the spring is completely charged, the circuit-breaker closes automatically. • Motor operating spring mechanism 1) (M1 *) In the case of motor operating spring mechanism, the closing spring is charged by means of the drive motor. When the spring is completely charged, the circuit-breaker closes automatically. • Motor operating stored-energy mechanism 1) (M1 *) In the case of motor operating stored-energy mechanism, the closing spring is charged by means of a motor and latched in the charged position (“spring charged” indication is visible). Closing is effected either by means of an ON pushbutton or a closing solenoid. The closing spring is recharged automatically. HA35-2632 eps Operating mechanisms Several operating mechanism types are available for the vacuum circuit-breaker: • Manual spring-operated mechanism • Motor operating spring mechanism • Motor operating stored-energy mechanism Further operating mechanism features • Located outside the switchgear vessel in the operating mechanism box and behind the control board • Operating mechanism for 2000 operating cycles. 8 Section through the vacuum circuit-breaker 1 2 3 4 5 6 7 8 Fixed terminal Pole support Vacuum interrupter Moving terminal Metal bellows Switchgear vessel, SF6-insulated, with vacuum interrupter Operating mechanism box Operating kinematics For further technical data and description of typical applications, please refer also to Catalog HG 11.05 “3AH5 Vacuum CircuitBreakers”. Endurance class of circuit-breaker Function Class Standard Property of NXPLUS C Wind BREAKING M2 IEC 62271-100 2000 times mechanically without maintenance E2 without ARE 2) IEC 62271-100 2000 times rated normal current without maintenance 20 times short-circuit breaking current without maintenance C2 IEC 62271-100 Very low probability of restrikes Operating times Closing time Closing solenoid < 75 ms Opening time 1st release 2nd release < 65 ms < 50 ms 1st release 2nd release < 80 ms < 65 ms Arcing time at 50 Hz Break time < 15 ms Dead time Total charging time 300 ms < 15 s ARE = Auto-reclosing 1) Motor rating at 24 V to 240 V DC: 600 W 100 V and 240 V AC: 750 VA 2) Class E2 with ARE on request * Item designation 14 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Vacuum circuit-breaker Shunt releases • Types: – Standard: 3AY15 10 (Y1 *) – Option: 3AX11 01 (Y2 *), with energy store • Tripping by protection relay or electrical actuation. 10 000 Anti-pumping (mechanical and electrical) • Function: If constant CLOSE and OPEN commands are present at the vacuum circuit-breaker at the same time, the vacuum circuit-breaker will return to the open position after closing. It remains in this position until a new CLOSE command is given. In this manner, continuous closing and opening (= pumping) is avoided. 5000 2000 1000 500 200 100 50 C.t.-operated release • Type 3AX11 02 (Y4 *), 0.5 A • Type 3AX11 04 (Y6 *) for tripping pulse ≥ 0.1 Ws in conjunction with suitable protection systems • Used if external auxiliary voltage is missing, tripping via protection relay. Undervoltage release • Type 3AX11 03 (Y7 *) • Comprising: – Energy store and unlatching mechanism – Electromagnetic system, which is permanently connected to voltage while the vacuum circuit-breaker is closed; tripping is initiated when this voltage drops • Connection to voltage transformers possible. HA35-2769_en eps Closing solenoid (only for motor operating stored-energy mechanism) • Type 3AY15 10 (Y9 *) • For electrical closing. Switching rate of the vacuum interrupter Permissible operating cycles Secondary equipment The scope of the secondary equipment of the vacuum circuitbreaker depends on the type of application and offers a wide range of variations, thus allowing even the highest requirements to be satisfied: 20 10 0.1 0.2 0.5 1 2 5 Varistor module • To limit overvoltages to approx. 500 V for protection devices (when inductive components are mounted in the vacuum circuit-breaker) • For auxiliary voltages ≥ 60 V DC. 20 kA 50 25 Breaking current (r.m.s. value) Electrical data Rated voltage 36 kV Rated short-circuit breaking current ≤ 25 kA Rated normal current ≤ 630 A Rated operating sequences O - t - CO - t - CO (t 3 min) O = OPEN operation CO = CLOSE operation with subsequent OPEN operation at the shortest internal close-open time of the vacuum circuit-breaker Possible release combinations Release Circuit-breaker tripping signal • For electrical signaling (as pulse > 10 ms), e.g. to remote control systems, in the case of automatic tripping (e.g. protection) • Via limit switch (S6 *) and cut-out switch (S7 *). 10 1 Release combination 2 3 4 5 6 1st shunt release type 3AY15 10 • • • • • 2nd shunt release type 3AX11 01 – • – – • • 3rd shunt release type 3AX11 01 – – – – – • C.t.-operated release type 3AX11 02, 0.5 A, or type 3AX11 04, 0.1 Ws – – • – • – Undervoltage release type 3AX11 03 – – – • – – • 1 unit of each release, a maximum of 3 releases can be combined. Auxiliary switch • Type 3SV9 (S1 *) • Standard: 6 NO + 6 NC, free contacts thereof 1) 3 NO + 4 NC • Option: 12 NO + 12 NC, free contacts thereof 1) 9 NO + 6 NC. Position switch • Type 3SE4 (S4 *) • For signaling “closing spring charged”. Mechanical interlock • Mechanical interlocking to the three-position disconnector • During operation of the three-position switch, the vacuum circuit-breaker cannot be operated. 1) For utilization by the customer * Item designation Abbreviations: NO = normally open contact NC = normally closed contact Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 15 Components Three-position switches HA35-2518a eps 1 CLOSED 2 3 OPEN 4 Feeder EARTHED Switch positions Three-position disconnector (in OPEN position) with vacuum circuit-breaker arranged below (view into the switchgear vessel opened at the rear) 1 2 3 4 Three-position switch-disconnector • Application in ring-main panel • Switch positions: CLOSED – OPEN – EARTHED • Switching functions as general-purpose switchdisconnector (class E3) according to: – IEC 60265-1 / VDE 0670-301 – IEC 62271-102 / VDE 0671-102 (for standards, see page 28) • Designed as a three-position switch with the functions: – Switch-disconnector and – Make-proof earthing switch. Fixed contact at the busbar Swivel-mounted contact blade Fixed contact for “feeder EARTHED” Operating shaft Busbar CLOSED OPEN HA35-2770 eps Three-position disconnector • Application in: – Circuit-breaker panel 630 A (with interlock against the circuit-breaker) – Disconnector panel 630 A and 1000 A • 1000 mechanical operating cycles for CLOSED / OPEN / READY-TO-EARTH. Switch positions of the three-position switches R-HA35-040a eps Common features • According to IEC 62271-102 and VDE 0671-102 (for standards, see page 28) • Application in hermetically welded switchgear vessel in conformity with the system • Climate-independent contacts in the SF6 -filled switchgear vessel • Maintenance-free for indoor installation according to IEC 62271-1 and VDE 0671-1 • Individual secondary equipment • A metal bellows is used for gasketless separation of the SF6 insulation and the operating mechanism (already used with success for over 2 million vacuum interrupters) • A rotary bushing is used for separation of the SF6 insulation and the operating mechanism (already used with success millions of times in medium-voltage and high-voltage switchgear) • Compact design due to short contact gaps in SF6 gas • Operation via gas-tight rotary bushing at the front of the switchgear vessel • Reliable mechanical switch position up to the operating front of the panel. CLOSED OPEN HA40-2150b eps EARTHED Feeder EARTHED Three-position switch-disconnector Switch positions 16 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Three-position switches Transmission principle for operating mechanisms HA35-2771 eps Interlocks • Selection of permissible switching operations by means of a control gate with mechanically interlocked vacuum circuitbreaker • Corresponding operating shafts are not released at the operating front until they have been pre-selected with the control gate • Operating lever cannot be removed until switching operation has been completed • Circuit-breaker cannot be closed until control gate is in neutral position again • Switchgear interlocking system also possible with electromechanical interlocks if switchgear is equipped with motor operating mechanisms (mechanical interlocking for manual operation remains). 2 Switch positions • “CLOSED”, “OPEN”, “EARTHED” or “READY-TO-EARTH” • In circuit-breaker panels, earthing and short-circuiting the cable connection is completed by closing the vacuum circuit-breaker. Transmission principle for operating mechanisms (see illustration) • Transmission of operating power from outside into the gas-filled switchgear vessel by means of a rotary bushing • Gas-tight • Maintenance-free. Three-position disconnector HA35-2521a eps Operating mechanism • Spring-operated mechanism, used in ring-main panel • Slow motion mechanism, used in: – Circuit-breaker panels – Disconnector panels 630 A, 1000 A • Spring-operated and slow motion mechanism actuated via operating lever at the operating front of the panel • Separate operating shafts for the DISCONNECTING and EARTHING or READY-TO-EARTH functions • Option: Motor operating mechanism for the DISCONNECTING and EARTHING or READY-TO-EARTH functions • Maintenance-free due to non-rusting design of parts subjected to mechanical stress • Bearings which require no lubrication. 1 1 2 1 Gas-filled switchgear vessel 2 Gas-tight welded-in rotary bushing Three-position switch-disconnector Endurance class of three-position disconnector Function Class Standard Property of NXPLUS C Wind DISCONNECTING M1 IEC 62271-102 2000 times mechanically without maintenance READY-TO-EARTH EARTHING 1000 times mechanically without maintenance E2 1) IEC 62271-102 5 times rated short-circuit making current Ima without maintenance Endurance class of three-position switch-disconnector Function Class Standard Property of NXPLUS C Wind DISCONNECTING M0 IEC 62271-102 1000 times mechanically without maintenance LOAD BREAKING M1 IEC 60265-1 E3 IEC 60265-1 1000 times mechanically without maintenance 100 times rated mainly active load breaking current I1 without maintenance 5 times rated short-circuit making current Ima without maintenance E2 IEC 62271-102 EARTHING 5 times rated short-circuit making current Ima without maintenance 1) By closing the circuit-breaker Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 17 Components Busbars Features • 1-pole, plug-in and bolted design • Consisting of round-bar copper, insulated by means of silicone rubber • Busbar joints with cross and end adapters, insulated by means of silicone rubber • Field control by means of electrically conductive layers on the silicone-rubber insulation (both inside and outside) • Touchable as the external layers are earthed with the switchgear vessel • Insensitive to pollution and condensation • Safe-to-touch due to metal cover • Switchgear extension or panel replacement is possible without SF6 gas work. R-HA35-051 eps Busbars (example) Busbars 1000 A, plug-in type, fully insulated (as front view of three panels, without low-voltage compartments) 1 7 2 8 3 4 9 5 6 10 HA35-2631 eps Section of 1000 A busbar (basic design) Panel width 450 / 600 mm 1 2 3 4 5 6 7 8 9 10 Cap Busbar insulation made of silicone rubber Clamps Busbar (round-bar copper) End adapter or coupling end adapter Switchgear vessel Metal cover of busbars Cross adapter Bushing Earthing connection 18 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Current transformers Features • According to IEC 60044-1 and VDE 0414-1 • Designed as ring-core current transformers, 1-pole • Free of dielectrically stressed cast-resin parts (due to design) • Insulation class E • Inductive type • Certifiable • Climate-independent • Secondary connection by means of a terminal strip in the low-voltage compartment of the panel. Mounting locations • At the panel connection (1) • Around the cable (2). Current transformer types • Feeder current transformer (1): – Inside ⭋ of transformer 106 mm – Max. usable height 205 mm • Cable-type current transformer (2) for shielded cables: – Inside ⭋ of transformer 55 mm – Max. usable height 170 mm • Zero-sequence current transformer (3) underneath the panels (included in the scope of supply); on-site installation. Front view: Side view: 1 1 2 2 3 3 HA35-2772 eps Installation • Arranged outside the primary enclosure (switchgear vessel). Current transformers 1 Feeder current transformer at the panel connection 2 Cable-type current transformer 3 Zero-sequence current transformer 630 A and 1000 A Current transformer installation in circuit-breaker panel (basic scheme) Electrical data Designation Type 4MC Operating voltage max. 0.8 kV Rated short-duration power-frequency withstand voltage (winding test) 3 kV Rated frequency 50 / 60 Hz Rated continuous thermal current max. 1.2 × rated current (primary) Rated thermal short-time current max. 20 kA / 3 s max. 25 kA / 1 s Rated current dynamic primary secondary unlimited 40 A to 600 A 1 A to 5 A Multiratio (secondary) 200 A – 100 A to 600 A – 300 A Core data according to rated primary current: Measuring core max. 3 cores Protection core Rating Class Overcurrent factor Rating Class Overcurrent factor 2.5 VA to 30 VA 0.2 to 1 FS 5, FS 10 2.5 VA to 30 VA 5 P or 10 P 10 to 30 Permissible ambient air temperature max. 60 °C Insulation class E Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 19 Components Panel connection 195 105 Panel width 600 mm 815 245 - 395* 730 265 - 415* L1 L2 L3 HA35-2774 eps 195 L3 500 HA35-2773 eps 105 L2 105 120 120 105 Panel width 450 mm Cable connection heights Panels Height of cable compartment mm Distance between bushing and cable bracket mm 450 mm 500 245 - 395 * 600 mm 730 / 815 265 - 415 * * The height of the cable brackets is adjustable. The distance depends on the position of the cable brackets. Connectable cables Cable T-plug with coupling insert 3 3 1 1 1 1 1 3 1 HA35-2602a eps Surge limiters • Pluggable on cable T-plug • Surge limiters recommended when motors with starting currents < 600 A are connected. L1 HA35-2600a eps Surge arresters • Pluggable on cable T-plug • Surge arresters recommended if, at the same time, – the cable system is directly connected to the overhead line, – the protection zone of the surge arrester at the end tower of the overhead line does not cover the switchgear. Cable compartment HA35-2599a eps Features • Bushings with outside cone • With bolted contact (M16) as interface type “C” according to EN 50 180 / EN 50 181 • For cable connection heights, see table on the right • Max. connection depth: – 408 mm in circuit-breaker panel – 540 mm in ring-main panel and disconnector panel • With cable bracket, e.g. type C40 according to DIN EN 50 024 • Option: Access to the cable compartment only if the feeder has been isolated and earthed • For thermoplastic-insulated cables • For shielded cable T-plugs with bolted contact • For connection cross-sections up to 630 mm2 • Larger cross-sections on request • Cable routing downwards, cable connection from the front • Cable plugs and cable sealing ends are not included in the scope of supply. Connection with 1 cable per phase Connection with 2 cables per phase Connection with 3 cables per phase Cable T-plug with coupling T-plug 1 HA35-2603a eps 2 HA35-2601a eps 1 Connection with 2 cables per phase Connection with 3 cables per phase 2 Legend 1 Cable T-plug 2 Coupling T-plug 3 Screw-type coupling insert 20 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Installation possibilities for cable connections and surge arresters, single-core PE and XLPE-insulated Number Make of cables per panel and phase Rated voltage Conductor crosssection 1) KV mm2 Insulation T-plug / phase Coupling inserts / coupling plugs Surge arresters with coupling inserts Arresters / phase Coupling unit 1× 400PB 5(10) SA-xxx – Circuit-breaker panel 630 A 1 Euromold 50 to 240 EPDM 1× M400TB/G – 36 50 to 240 EPDM 1× M430TB/G – 1× 300SA-10-xx – 36 300 to 630 EPDM 1× M440TB/G – 1× 400PB 5(10) SA-xxx – Südkabel 36 70 to 500 Silicone 1× SEHT 33 – 1× MUT33 1× KU33 nkt cables 36 25 to 300 Silicone 1× CB36-630 – 1× CSA36-10 – 36 400 to 630 Silicone 1× CB36-630 (1250) – 1× CSA36-10 – 36 25 to 300 Silicone 1× RSTI-66xx – 1× RSTI-CC-66SAxxx – 36 25 to 300 Silicone 1× RSTI-68xx – – – 36 400 to 630 Silicone 1× RSTI-66Lxx – 1× RSTI-66SAxxx 1× RSTI-66CP-M16 Tyco Electronics Raychem 2 36 Euromold Südkabel nkt cables Tyco Electronics Raychem 36 400 to 800 Silicone 1× RSTI-69xx – – – 36 50 to 240 EPDM 2× M400TB/G 1× M400CP – – 36 50 to 240 EPDM 1× M430TB/G 1× M300PB-630A – – 36 300 to 630 EPDM 2× M440TB/G 1× M400CP – – 36 70 to 500 Silicone 2× SEHT 33 1× KU33 – – 36 25 to 300 Silicone 1× CB36-630 1× CC36-630 – – 36 25 to 300 Silicone 2× CB36-630 1× CP 630C – – 36 400 to 630 Silicone 1× CB36-630 (1250) 1× CC36-630 (1250) – – 36 25 to 300 Silicone 1× RSTI-66xx 1× RSTI-CC-66xx – – 36 25 to 300 Silicone 1× RSTI-68xx 1× RSTI-CC-68xx – – 36 400 to 630 Silicone 2× RSTI-66Lxx 1× RSTI-66CP-M16 – – 36 400 to 800 Silicone 1× RSTI-69xx 1× RSTI-CC-69xx – – Diconnector panel 630 A • Disconnector panel 1000 A • Ring-main panel 630 A 1 Euromold 50 to 240 EPDM 1× M400TB/G – 1× 400PB 5(10) SA-xxx – 36 50 to 240 EPDM 1× M430TB/G – 1× 300SA-10-xx – 36 300 to 630 EPDM 1× M440TB/G – 1× 400PB 5(10) SA-xxx – Südkabel 36 70 to 500 Silicone 1× SEHT 33 – 1× MUT33 1× KU33 nkt cables 36 25 to 300 Silicone 1× CB36-630 – 1× CSA36-10 – 36 400 to 630 Silicone 1× CB36-630 (1250) – 1× CSA36-10 – 36 25 to 300 Silicone 1× RSTI-66xx – 1× RSTI-CC-66SAxxx – Tyco Electronics Raychem 2 36 Euromold 36 25 to 300 Silicone 1× RSTI-68xx – – – 36 400 to 630 Silicone 1× RSTI-66Lxx – 1× RSTI-66SAxxx 1× RSTI-66CP-M16 36 400 to 800 Silicone 1× RSTI-69xx – – – 36 50 to 240 EPDM 2× M400TB/G 1× M400CP – – 36 50 to 240 EPDM 1× M430TB/G 1× M300PB-630A – – 36 300 to 630 EPDM 2× M440TB/G 1× M400CP – – Südkabel 36 70 to 500 Silicone 2× SEHT 33 1× KU33 – – nkt cables 36 25 to 300 Silicone 1× CB36-630 1× CC36-630 1× CSA36-10 – 36 25 to 300 Silicone 2× CB36-630 1× CP 630C 1× CSA36-10 – 36 400 to 630 Silicone 1× CB36-630 (1250) 1× CC36-630 (1250) 1× CSA36-10 – 36 25 to 300 Silicone 1× RSTI-66xx 1× RSTI-CC-66xx 1× RSTI-CC-66SAxxx – 36 25 to 300 Silicone 1× RSTI-68xx 1× RSTI-CC-68xx – – 36 400 to 630 Silicone 2× RSTI-66Lxx 1× RSTI-66CP-M16 1× RSTI-66SAxxx 1× RSTI-66CP-M16 36 400 to 800 Silicone 1× RSTI-69xx 1× RSTI-CC-69xx – – Tyco Electronics Raychem 1) Observe the actual short-circuit and current carrying capacity of the cables and sealing ends Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 21 Components Installation possibilities for cable connections and surge arresters, single-core PE and XLPE-insulated, panel connection Number Make of cables per panel and phase Rated voltage Conductor crosssection 1) KV mm2 Insulation T-plug / phase Coupling inserts / coupling plugs Surge arresters with coupling inserts Arresters / phase Coupling unit – Diconnector panel 630 A • Diconnector panel 1000 A • Ring-main panel 630 A 3 nkt cables Tyco Electronics Raychem 36 25 to 300 36 25 to 300 36 400 to 630 36 25 to 300 36 25 to 300 36 36 Silicone 1× CB36-630 2× CC36-630 – Silicone 3× CB36-630 2× CP 630C – Silicone 1× CB36-630 (1250) 2× CC36-630 (1250) – – Silicone 1× RSTI-66xx 2× RSTI-CC-66xx – – Silicone 1× RSTI-68xx 2× RSTI-CC-68xx – – 400 to 630 Silicone 3× RSTI-66Lxx 2× RSTI-66CP-M16 – – 400 to 800 Silicone 1× RSTI-69xx 2× RSTI-CC-69xx Panel connection Cable type Cable sealing end Make Type Comment Cross-section mm2 Thermoplastic-insulated cables 36 kV according to IEC 60502-2 and VDE 0276-620 Single-core cable, Euromold PE and XLPE-insulated N2YSY (Cu) and N2XSY (Cu) Südkabel or nkt cables NA2YSY (Al) and NA2XSY (Al) Tyco Electronics Raychem M400TB/G M430TB/G M440TB/G 50 to 240 50 to 240 300 to 630 EPDM with semi-conductive layer EPDM with semi-conductive layer EPDM with semi-conductive layer SEHDT 33 70 to 500 Silicone with semi-conductive layer (optionally with metal housing) CB 36-630 CB 36-630 (1250) 25 to 300 400 to 630 Silicone with semi-conductive layer (optionally with metal housing) Silicone with semi-conductive layer (optionally with metal housing) RSTI-66xx RSTI-68xx RSTI-66Lxx RSTI-69xx 25 to 240 25 to 240 400 to 630 400 to 800 Silicone with semi-conductive layer, with capacitive measuring point Silicone with semi-conductive layer, with capacitive measuring point Silicone with semi-conductive layer, with capacitive measuring point Silicone with semi-conductive layer, with capacitive measuring point 1) Observe the actual short-circuit and current carrying capacity of the cables and sealing ends 22 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Indicating and measuring equipment Indicators and detecting systems Symbols shown VOIS+, VOIS R+ CAPDIS-S1+ CAPDIS-S2+ L1 L2 L3 R-HA40-103 eps Voltage detecting systems according to IEC 61243-5 or VDE 0682-415 • To verify safe isolation from supply • LRM detecting systems – with plug-in indicator – with integrated indicator, type VOIS+, VOIS R+, WEGA ZERO – with integrated indicator, with integrated repeat test of the interface, with integrated function test, type CAPDIS-S1+, WEGA 1.2, and additionally with integrated signaling relays type CAPDIS-S2+, WEGA 2.2. Plug-in voltage indicator per phase at the panel front L1 L2 L3 L1 L2 L3 A0 A1 A2 A3 R-HA40-104 eps Plug-in voltage indicator • Verification of safe isolation from supply phase by phase • Indicator suitable for continuous operation • Measuring system and voltage indicator can be tested • Voltage indicator flashes if high voltage is present. CAPDIS-Sx+ Common features • Maintenance-free • Integrated display, without auxiliary power • Integrated repeat test of the interfaces (self-monitoring) • With integrated function test (without auxiliary power) by pressing the “Display-Test” pushbutton • With integrated 3-phase LRM test socket for phase comparison. CAPDIS-S1+ • Without auxiliary power • With indication “A1” to “A5” (see legend) • Without ready-for-service monitoring • Without signaling relays (thus without auxiliary contacts). CAPDIS-S2+ • With indication “A0” to “A6” (see legend) • Only by pressing the “Display-Test” pushbutton: “ERROR” indication (A6), e.g. in case of missing auxiliary voltage • With ready-for-service monitoring (external auxiliary power required) • With integrated signaling relay for signals (auxiliary power required) • With signal-lead test. A6 ERROR Integrated voltage indicator VOIS+, VOIS R+ R-HA35-154 eps R-HA35-155 eps HA35-2579a eps A5 A0 CAPDIS-S2+: Operating voltage not present A1 Operating voltage present A2 – Operating voltage not present – For CAPDIS-S2+: Auxiliary power not present A3 Failure in phase L1, operating voltage at L2 and L3 (for CAPDIS-Sx+ also earth-fault indication) A4 Voltage (not operating voltage) present A5 Indication “Display-Test” passed A6 Indication “ERROR”, e.g.: in case of missing auxiliary voltage Integrated voltage detecting system CAPDIS-S1+, -S2+ HA35-2537a eps VOIS+, VOIS R+ • Integrated display, without auxiliary power • With indication “A1” to “A3” (see legend) • Maintenance-free, repeat test required • With integrated 3-phase LRM test socket for phase comparison • With integrated signaling relays (only VOIS R+). A4 ULE L1 L2 L3 C1 C2 U2 LRM system CAPDIS / VOIS plugged in installed Voltage indication via capacitive voltage divider (principle) – C1 Capacity integrated into bushing – C2 Capacity of the connection leads and the voltage indicator to earth ULE = UN / 3 during rated operation in the three-phase system U2 = UA = Voltage at the capacitive interface of the switchgear or at the voltage indicator Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 23 Components Indicating and measuring equipment WEGA ZERO • Voltage detecting system according to IEC 61958 or VDE 0670-502 • With indication “A1” to “A4” (see legend) • Maintenance-free • With integrated 3-phase test socket for phase comparison. WEGA 1.2 WEGA 2.2 L1 L2 L3 L1 L2 L3 L1 L2 L3 R-HA35-151.eps A1 A2 A3 A4 HA35-2758 eps A5 A6 R-HA35-152.eps LC display gray: not illuminated LC display white: illuminated Integrated voltage detecting system WEGA 1.2 R-HA35-153.eps WEGA 2.2 • Voltage detecting system according to IEC 61243-5 or VDE 0682-415 • With indication “A0” to “A6” (see legend) • Maintenance-free • Integrated repeat test of the interface (self-monitoring) • With integrated function test (without auxiliary power) by pressing the “Display-Test” pushbutton • With integrated 3-phase LRM test socket for phase comparison • With integrated signaling relay • Auxiliary power required. WEGA ZERO A0 Integrated voltage indicator WEGA ZERO Integrated voltage detecting system WEGA 2.2 HA35-2537a eps WEGA 1.2 • Voltage detecting system according to IEC 61243-5 or VDE 0682-415 • With indication “A1” to “A5” (see legend) • Maintenance-free • Integrated repeat test of the interface (self-monitoring) • With integrated function test (without auxiliary power) by pressing the “Display-Test” pushbutton • With integrated 3-phase LRM test socket for phase comparison • Without integrated signaling relay • Without auxiliary power. Symbols shown ULE L1 L2 L3 C1 C2 A0 For WEGA 2.2: Operating voltage not present, auxiliary power present, LCD illuminated A1 Operating voltage present For WEGA 2.2: Auxiliary power present, LCD illuminated A2 Operating voltage not present For WEGA 2.2: Auxiliary power not present, LCD not illuminated A3 Failure in phase L1, operating voltage at L2 and L3 For WEGA 2.2: Auxiliary power present, LCD illuminated A4 Voltage present, current monitoring of coupling section below limit value For WEGA 2.2: Auxiliary power present, LCD illuminated A5 Indication “Display-Test” passed For WEGA 2.2: Auxiliary power present, LCD illuminated A6 For WEGA 2.2: LCD for missing auxiliary voltage is not illuminated U2 LRM system WEGA plugged in installed Voltage indication via capacitive voltage divider (principle) – C1 Capacity integrated into bushing – C2 Capacity of the connection leads and the voltage indicator to earth ULE = UN / 3 during rated operation in the three-phase system U2 = UA = Voltage at the capacitive interface of the switchgear or at the voltage indicator 24 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Indicating and measuring equipment R-HA40-089 eps Phase comparison test units according to IEC 61243-5 or VDE 0682-415 R-HA40-059 eps Verification of correct terminal-phase connections • Verification of correct terminalphase connections possible by means of a phase comparison test unit (can be ordered separately) • Safe-to-touch handling of the phase comparison test unit by inserting it into the capacitive taps (socket pairs) of the switchgear. R-HA35-127.eps Phase comparison test unit make Pfisterer, type EPV Phase comparison test unit make Horstmann, type ORION 3.0 as combined test unit for: – Phase comparison – Interface testing at the switchgear – Voltage detection for LRM systems – Integrated self-test – Indication via LED and acoustic alarm Phase comparison test unit make Kries, type CAP-Phase as combined test unit (HR and LRM) for: – Voltage detection – Repeat test – Phase comparison – Phase sequence test – Self-test The unit does not require a battery Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 25 Components Indicating and measuring equipment Ready-for-service indicator 2 3 4 5 Control board (detail) with red / green ready-for-service indicator Mode of operation For the ready-for-service indicator, a gas-tight measurement box is installed inside the switchgear vessel. A coupling magnet, which is fitted to the bottom end of the measurement box, transmits its position to an outside armature through the non-magnetizable switchgear vessel. This armature moves the ready-for-service indicator of the switchgear. While changes in the gas density during the loss of gas, which are decisive for the dielectric strength, are displayed, temperature-dependent changes in the gas pressure are not. The gas in the measurement box has the same temperature as that in the switchgear. The temperature effect is compensated via the same pressure change in both gas volumes. ReadyStainless-steel vessel filled with SF6 gas, relative pressure forservice 50 kPa at 20 °C indicator Principle of operation of gas monitoring with ready-for-service indicator Ready-for-service indicator Measurement box Magnetic coupling Red indication: not ready for service 5 Green indication: Ready for service 1 2 3 4 Low-voltage compartment R-HA35-105 eps Low-voltage compartment • For accommodation of protection, control, measuring and metering equipment • Partitioned safe-to-touch from the high-voltage part of the panel • Low-voltage compartment can be removed, bus wires and control cables are plugged in • O ption: Higher low-voltage compartment (650 mm instead of 325 mm) possible. HA35-2538a eps R-HA35-161 eps Gas monitoring Features • Self-monitoring; easy to read • Independent of temperature and pressure variations • Independent of the site altitude • Only responds to changes in gas density • O ption: Alarm switch “1NO + 1NC” for remote electrical indication. Low-voltage compartment with multifunction protection relay SIPROTEC 4 7SJ61 (example) For description of the SIPROTEC 4 multifunction protection relays, see page 27 26 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Components Protection, control, measuring and monitoring equipment The low-voltage compartment can accommodate all customary protection, control, measuring and monitoring equipment available on the market (e.g.): Multifunction protection relay SIPROTEC 4 7SJ63 • For stand-alone or master operation • Communications and bus capability • Functions: Protection, control, signaling, communication and measuring • LC display for process and equipment data in the form of a feeder control diagram and as text, e.g. for – Measuring and metering values – Information on status of switchgear and switching device – Protection data – General indications – Alarms • Four freely programmable function keys for frequently performed functions • Fourteen freely programmable LEDs for displaying any desired data • Two key-operated switches to switch between “local and remote control” and “interlocked and non-interlocked operation” • Keys for navigation in menus and for entering values • Integrated motor control by special relays with enhanced performance • Fault recorder. 2 LC display LEDs Key-operated switches Navigation keys Control keys Function keys LC text display 7 4 R-HA35-104 eps Multifunction protection relay SIPROTEC 4 7SJ61 / 7SJ62 • For stand-alone or master operation • Communications and bus capability • Functions: Protection, control, signaling, communication and measuring • LC text display (4 lines) for process and equipment data, as text, e.g. for – Measuring and metering values – Information on status of switchgear and switching device – Protection data – General indications – Alarms • Four freely programmable function keys for frequently performed functions • Seven freely programmable LEDs for displaying any desired data • Keys for navigation in menus and for entering values • Fault recorder. 1 2 3 4 5 6 7 Multifunction protection relay SIPROTEC 4 7SJ600 / 7SJ602 7 4 2 6 R-HA35-103 eps Multifunction protection relay SIPROTEC 4 7SJ600 / 7SJ602 • User-friendly operating program DIGSI 4 for configuration and analysis • Communications and bus capability • Functions: Protection, control, signaling, communication and measuring • LC text display (2 lines) and keyboard for local operation, configuration and indication • Four freely programmable LEDs for displaying any desired data • Operation and fault indication memory • Fault recorder • Circuit-breaker control. Multifunction protection relays SIPROTEC 4 Multifunction protection relay SIPROTEC 4 7SJ61 / 7SJ62 1 4 2 5 R-HA35-102 eps 3 6 Multifunction protection relay SIPROTEC 4 7SJ63 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 27 Standards Standards, specifications, guidelines Type of service location The switchgear can be used as indoor installation according to IEC 61936 (Power installations exceeding 1 kV AC) and VDE 0101 • Outside lockable electrical service locations at places which are not accessible to the public. Enclosures of switchgear can only be removed with tools • In lockable electrical service locations. A lockable electrical service location is a place outdoors or indoors that is reserved exclusively for housing electrical equipment and which is kept under lock and key. Access is restricted to authorized personnel and persons who have been properly instructed in electrical engineering. Untrained or unskilled persons may only enter under the supervision of authorized personnel or properly instructed persons. Terms “Make-proof earthing switches” are earthing switches with short-circuit making capacity according to IEC 62271-102 and VDE 0671-102 / EN 62 271-102. Standards NXPLUS C Wind switchgear complies with the relevant standards and specifications applicable at the time of type tests. In accordance with the harmonization agreement reached by the countries of the European Union, their national specifi cations conform to the IEC standard. Dielectric strength • The dielectric strength is verified by testing the switchgear with rated values of short-duration power-frequency withstand voltage and lightning impulse withstand voltage according to IEC 62271-1 / VDE 0671-1 (see table “Dielectric strength”). • The rated values are referred to sea level and to normal atmospheric conditions (1013 hPa, 20 °C, 11g/m3 humidity according to IEC 60071 and VDE 0111). The gas insulation at a relative gas pressure of 50 kPa permits switchgear installation at any desired altitude above sea level without the dielectric strength being adversely affected. This also applies to the cable connection when plug-in sealing ends are used. Table – Dielectric strength Rated voltage (r.m.s. value) kV Rated short-duration power-frequency withstand voltage (r.m.s. value) – Between phases and to earth kV 70 – Across isolating distances kV 80 – Between phases and to earth kV 170 – Across isolating distances kV 180 Rated lightning impulse withstand voltage (peak value) Overview of standards (June 2011) IEC standard VDE standard EN standard Switchgear NXPLUS C Wind IEC 62271-1 VDE 0671-1 EN 62 271-1 IEC 62271-200 VDE 0671-200 EN 62 271-200 Devices Circuit-breakers IEC 62271-100 VDE 0671-100 EN 62 271-100 Degree of protection 36 Disconnectors and earthing switches IEC 62271-102 VDE 0671-102 EN 62 271-102 Switch-disconnectors IEC 60265-1 VDE 0670-301 EN 60 265-1 Voltage detecting systems IEC 61243-5 VDE 0682-415 EN 61 243-5 IP code IEC 60529 VDE 0470-1 EN 60 529 IK code IEC 62262 VDE 0470-100 EN 50 102 Insulation – IEC 60071 VDE 0111 EN 60 071 Instrument transformers Current transformers IEC 60044-1 VDE 0414-1 EN 60 044-1 Installation, erection – IEC 61936-1 VDE 0101 – 28 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Standards Standards, specifications, guidelines Current carrying capacity • According to IEC 62271-200 or IEC 62271-1, VDE 0671-200 or VDE 0671-1, the rated normal current refers to the following ambient air temperatures: – Maximum of 24-hour mean + 35 °C – Maximum + 40 °C • The current carrying capacity of the panels and busbars depends on the ambient air temperature outside the enclosure. Internal arc classifications • Protection of operating personnel by means of tests for verifying the internal arc classification • Internal arcing tests must be performed in accordance with IEC 62271-200 or VDE 0671-200 • Definition of criteria: – Criterion 1: Correctly secured doors and covers do not open, limited deformations are accepted. – Criterion 2: No fragmentation of the enclosure, no projection of small parts above 60 g – Criterion 3: No holes in accessible sides up to a height of 2 m – Criterion 4: No ignition of indicators due to hot gases – Criterion 5: The enclosure remains connected to its earthing point. Resistance to internal faults Due to the single-pole enclosure of external components and the SF6 insulation of switching devices, the possibility of faults in SF6 -insulated switchgear is improbable and a mere fraction of that typical of earlier switchgear types: • There are no effects due to external influences, such as: – Pollution layers – Humidity – Small animals and foreign objects • Maloperation is practically excluded due to logical arrangement of operating elements • Short-circuit-proof feeder earthing by means of the circuitbreaker or the three-position switch-disconnector. In the unlikely event of a fault within the switchgear vessel, the energy conversion in the case of an internal arc fault is minor thanks to the SF6 insulation and the shorter arc length, i.e. approximately only 1/3 compared to air. The escaping gases are discharged upwards through a pressure relief duct (option). Climate and environmental influences The parts of the primary circuit of NXPLUS C Wind switchgear under high voltage are completely enclosed and insensitive to climatic influences. • All medium-voltage devices are installed in a gas-tight, welded stainless-steel switchgear vessel which is filled with SF6 gas • Live parts outside the switchgear vessel are provided with single-pole enclosure • At no point can creepage currents flow from high-voltage potentials to earth • Operating mechanism parts which are functionally important are made of corrosion-resistant materials • Bearings in the operating mechanism are designed as dry-type bearings and do not require lubrication. The NXPLUS C Wind switchgear is suitable for application in indoor installations under normal operating conditions as defined in the standard IEC 62271-1. Furthermore, the high-voltage part of the NXPLUS C Wind switchgear can be used in environmental conditions of the climatic category 3C2 according to the standard IEC 60721-3-3. Protection against solid foreign objects, electric shock and water NXPLUS C Wind switchgear fulfills according to the standards IEC 62271-1 VDE 0671-1, EN 62 271-1 IEC 62271-200 VDE 0671-200, EN 62 271-200 IEC 60529 VDE 0470-1, EN 60 529 IEC 62262 VDE 0470-100, EN 50 102 the following degrees of protection: Degree of protection IP Type of protection IP 65 for parts of the primary circuit under high voltage IP 3XD for switchgear enclosure IP 31D for low-voltage compartment (option) Degree of protection IK Type of protection IK 07 for switchgear enclosure Aseismic capacity (option) NXPLUS C Wind switchgear can be upgraded for regions at risk from earthquakes. For upgrading, earthquake qualification testing has been carried out in accordance with the following standards: • IEC 60068-3-3 “Guidance – seismic test methods for equipment” • IEC 60068-2-57 “Test Ff: Vibration – Time-history method” • IEC 60068-2-59 “Test Fe: Vibration – Sine-beat method” • IEEE 693-2005 “Recommended Practice for Seismic Design of Substations”. For installation on even and rigid concrete or steel structure (without considering building influences), the tested ground accelerations meet the following requirements: • Uniform Building Code 1997 (UBC) – Zone 4 • California Building Code 1998 (CBC) – Zone 4 • IEEE 693-2005 – High required response spectrum (Figure A.1). Color of the panel front Siemens standard (SN) 47 030 G1, color no. 700 / light basic (similar to RAL 7047 / gray). Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 29 Notes 30 Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C Wind up to 36 kV, Gas-Insulated · Siemens HA 35.61 · 2011 Published by and copyright © 2011: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Power Distribution Division Medium Voltage Postfach 3240 91050 Erlangen, Germany www.siemens.com / medium-voltage-switchgear For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-Mail: support.energy@siemens.com Order No. E50001-K1435-A611-A1-7600 Printed in Germany Dispo 30403, c4bs 7475 KG 06.11 2.0 32 En 3600 / 34829 WÜ Printed on elementary chlorine-free bleached paper. All rights reserved. If not stated otherwise on the individual pages of this catalog, we reserve the right to include modifications, especially regarding the stated values, dimensions and weights. Drawings are not binding. All product designations used are trademarks or product names of Siemens AG or other suppliers. If not stated otherwise, all dimensions in this catalog are given in mm. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract. www.siemens.com/energy