DATA SHEET DC Surge Protection for Remote Radio Heads CB Product Series Overvoltage Protection & Fiber Management Junction Box powered by The deployment of Remote Radio Head (RRH) architecture poses unique challenges to the mobile industry. Raycap's innovative RRH protection solutions mitigate the risk of damage due to lightning and provide high levels of availability and reliability to radio equipment. Port size and configuration of enclosure may differ from what is shown. Features The CB Product Series utilizes the patented Strikesorb® 30-V1-HV Surge Protective Device (SPD), specifically designed for the Remote Radio Head (RRH) installation environment and certified for use in low, 48 volt DC operating applications. The Strikesorb 30-V1-HV is a Class I SPD, certified by VDE per the IEC 61643-11 Safety Standard as suitable for installation in areas where direct lightning exposure is expected. Strikesorb 30-V1-HV is able to withstand direct lightning currents of up to 5 kA (10/350 µs) and induced surge currents of up to 60 kA (8/20 µs). Provides very low clamping/let-through voltage, unique for a Class I product, as it does not employ spark gaps or other switching elements. Strikesorb offers unique protection levels to the RRH equipment as well as the baseband units. Fully Recognized to UL 1449 4th Edition Safety Standard Patent pending design Benefits Offers unique maintenance-free protection against direct lightning currents. Protects up to four RRHs and provides connection for fiber optic pairs. Utilizes an ingress protection rated, IP 67 enclosure, allowing for indoor or outdoor installation on a roof or tower top. Configurable cable ports are designed to accommodate varying diameters of hybrid (combined power and fiber optic) or standard cables with diameters up to 1.625" [41.27mm] depending upon port configuration. Lightweight design allows for easy tower top installation. PSM-48 Mounting Bracket Included www.raycap.com Strikesorb is a registered trademark of Raycap © 2016 Raycap All rights reserved. G02-00-132 160621 DC Surge Protection for Remote Radio Heads SPECIFICATIONS CB Product Series Overvoltage Protection & Fiber Management Junction Box Electrical CB Series Surge Protective Device (SPD) Class to IEC 61643-11 Class I Nominal Operating DC Voltage [Un] 48 V Nominal Discharge Current [In] 20 kA 8/20 µs Maximum Surge Current [Imax] 60 kA 8/20 µs Maximum Impulse (Lightning) Current [Iimp] per IEC 61643-11 5 kA 10/350 µs Maximum Continuous Operating DC Voltage [Uc] (MCOV) 75 V Voltage Protection Rating (VPR) per UL 1449 4th Edition 400 V Strikesorb Module Type 30-V1-HV Incoming Power/Fiber Configurable to customer specifications Form C Dry Contacts Optional Alarm Mechanical Connection Terminal (Suppression) Method Connection Terminal (Suppression) Hardwired Fiber Connection Method Compression lug Copper #14 to #2/0 AWG [2.5 to 70 mm2] Aluminum #12 to #2/0 AWG [4 to 70 mm2] LC-LC Single or Dual mode to customer specifications Environmental Ingress Protection (IP) Rating IP 67 Operating Temperature -40° C to +80° C UV Resistant Yes Combined Wind Load Enclosure Dimension (L × W × H) Sustained 150 mph: 96 lbs/force [427 N] Gusts 195 mph: 162 lbs/force [721 N] 13.56" × 5.22" × 13.22" [344.5 × 132.6 × 335.7 mm] Weight System 9 lbs [4.08 kg] Mount 4 lbs [1.81 kg] Total 13 lbs [5.89 kg] Standards Compliance & Certifications Strikesorb modules are compliant to the following Surge Protective Device (SPD) standards: Standards UL 1449 4th Ed, IEC 61643-11, EN 61643-11:2012, IEEE C62.41: 2002, IEEE C62.45: 2002, Certi ications UL, VDE, CE Associations ANSI, EN, IEC, IEEE, NEC Product Diagram [mm] inches [162.2] 6.39 [344.5] 13.56 [132.6] 5.22 [203.2] 8.00 [335.7] 13.22 Port size and configuration of enclosure may differ from what is shown. AWG=American Wire Gauge [323.9] 12.75 www.raycap.com G02-00-132 160621