TECHNICAL SPECIFICATIONS MULTI-SECTIONAL DOME LAMP HM-DM1, HM-DM2, HM-DM3, HM-DM4 MAXIMUM VISIBILITY FOUR LAMP COLORS AVAILABLE PLUG IN BULBS FLEXIBLE INSTALLATION Front Rear DESCRIPTION HOUSING AND FINISH The multi-sectional dome lamp, DM-1 thru DM-4, shall be surface, wall or ceiling mounted available for use as 1 section (single) to 4 section dome lamp. Faceplate: High impact molded ABS with flame retardant properties finished in off-white. Dome Lens: High impact translucent acrylic with flame retardant properties finished in white translucent. LAMP Bayonet type, long life incandescent lamps rated at 100 mA at 28 volts DC each, replaceable from the front. Available colors; white, red, green or amber. INSTALLATION Prewired connectors to facilitate easy installation. Mount using only the four 6-32 x 1" nylon screws provided. DIMENSIONS Faceplate & Dome Lens: 4 ½" (11.43cm) high x 4 9/16" (11.59cm) wide x 3" (7.62cm) deep. W42 Backbox: 4-11/16” (11.91cm) wide square electrical backbox with two gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-DM# is UL listed Hospital Signaling Equipment / Nurse Call Equipment under file number E206037. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-DM-# Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-DM-# MULTI-SECTIONAL DOME LAMP The multi-sectional dome lamp, DM-1 thru DM-4, shall be surface, wall or ceiling mounted available for use as 1 section (single) to 4 section dome lamp. The HM-DM-# shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under file number E206037. The lamps shall be Bayonet type, long life incandescent lamps rated at 100 mA at 28 volts DC each, replaceable from the front. Available colors; white, red, green or amber. The HM-DM# shall use prewired connectors to facilitate easy installation and mount using only the four 6-32 x 1" nylon screws provided. The faceplate shall be of high impact molded ABS with flame retardant properties finished in off-white. The dome lens shall be of high impact translucent acrylic with flame retardant properties finished in white translucent. The Faceplate & Dome Lens shall be 4 ½" (11.43cm) high x 4 9/16" (11.59cm) wide x 3" (7.62cm) deep. W42 Backbox: 4-11/16” (11.91cm) wide square electrical backbox with two gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 03/04 HM-DM-# Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS ONE BUTTON SWITCH PANEL HM-1B, HM-1B/K2 Illuminated Pushbutton Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted one button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS One combination pushbutton and lamp indicator. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are front replaceable with rated average life of 6000 hours. SWITCH Switch is normally-open, single-pole / single throw. HM-1B is momentary operation, HM-1B/ K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Rear Side INSTALLATION Plugs into prewired connectors. HM-1B requires one HM-4P HM-1B/K2 requires one HM-4P Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-1B/K2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM1B Issue C Printed in U.S.A. Architects’ and Engineers’ Specifications Model HM-1B / 1B/K2 One Button Switch Panel The wall recessed or surface mounted HM-1B / HM-1B/K2 One Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push button shall be used for feature activation. Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-1B/K2 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-1B shall contain one momentary normally-open SPST switch; the HM-1B/K2 shall contain one latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM1B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TWO BUTTON SWITCH PANEL HM-2B, HM-2B/K2 Illuminated Pushbuttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted two button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Two combination pushbutton and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. SWITCH Switches are normally-open, single-pole / single throw. HM-2B is momentary operation, HM-2B/ K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Top: HM-2B Bottom: HM-2B/K2 INSTALLATION Plugs into prewired connectors. HM-2B requires one HM-6P HM-2B/K2 requires two HM-4P Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-2B/K2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM2B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-2B / HM-2B/K2 TWO BUTTON SWITCH PANEL The wall recessed or surface mounted HM-2B / HM-2B/K2 Two Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with two combination pushbutton and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-2B/K2 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-2B shall contain two momentary normally-open SPST switches; the HM-2B/K2 shall contain two latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM2B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS THREE BUTTON SWITCH PANEL HM-3B, HM-3B/K2 Illuminated Pushbuttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted three button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Three combination pushbutton and lamp indicator. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. SWITCH Switches are normally-open, single-pole / single throw. HM-3B is momentary operation, HM-3B/ K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Top: 3B Bottom: 3B/K2 Top: 3B Bottom: 3B/K2 INSTALLATION Plugs into prewired connectors. HM-3B requires one HM-8P HM-3B/K2 requires three HM-4P Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-3B/K2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM3B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-3B - 3B/K2 THREE BUTTON SWITCH PANEL The wall recessed or surface mounted HM-3B / HM-3B/K2 Three Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with three combination pushbutton and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-3B/K2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-3B shall contain three momentary normally-open SPST switches; the HM-3B/K2 shall contain three latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM3B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FOUR BUTTON SWITCH PANEL HM-4B, HM-4B/K2 H M 4 B Illuminated Push-buttons Momentary or Latching Switches Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connector HM-4B, 4B/K2 FRONT DESCRIPTION Wall recessed or surface mounted four button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Four combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, black. Lamps are front replaceable with rated average life of 6000 hours. Lamps are rated at 24 VDC at 40 mA. SWITCHES Switches are normally-open single-pole/single throw. HM-4B is momentary operation, HM-4B/ K2 is latching (push-on / push-off). Switch contacts rated 1A - 125 VAC. H M 4 B / K 2 INSTALLATION Plugs into prewired connectors. HM-4B requires one HM-10P connector. HM-4B/K2 requires four HM-4P connectors. Mount using only the four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white supplied with nylon mounting screws; W42 Backbox: metal backbox supplied by others. DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. Important Note: Backbox to be installed rotated 90 degrees for proper panel orientation. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM4B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-4B - HM4B/K2 FOUR BUTTON SWITCH PANEL The wall recessed or surface mounted HM-4B / HM4B/K2 Four Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with four combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-4B shall contain four momentary normally-open SPST switches; the HM-4B/K2 shall contain four latching normally-open SPST switches (push-on / push-off). Faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Four 6-32 x 1" nylon screws shall be provided for attaching switch plate to backbox. Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied by others. Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM4B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS SIX BUTTON SWITCH PANEL HM-2-3B, HM-2-3B/K2 2 3 B / K 2 Illuminated Pushbuttons Variety of Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation 2 3 B Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted six button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Six combination pushbuttons and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are front replaceable with rated average life of 6000 hours. Lamps are rated 24 VDC at 40 mA. SWITCHES Switches are normally-open, single-pole / single throw. HM-2-3B is momentary operation, HM-23B/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. INSTALLATION Plugs into prewired connectors. HM-2-3B requires two HM-8P HM-2-3B/K2 requires six HM-4P HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. IMPORTANT NOTE: Backbox to be installed rotated 90 degrees for proper panel orientation. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-2-3B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-2-3B - HM-2-3B/K2 SIX BUTTON SWITCH PANEL The wall recessed or surface mounted HM-2-3B Six Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with six combination pushbuttons and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-2-3B shall contain six momentary normally-open SPST switches; the HM-2-3B/K2 shall contain six latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 3-5/16" (8.41cm), supplied by others. Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-2-3B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS EIGHT BUTTON SWITCH PANEL HM-2-4B, HM-2-4B/K2 2 4 B / K 2 Illuminated Pushbuttons Variety of Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation 2 4 B Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted eight button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Eight combination pushbuttons and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are front replaceable with rated average life of 6000 hours. Lamps are rated 24 VDC at 40 mA. SWITCHES Switches are normally-open, single-pole / single throw. HM-2-4B is momentary operation, HM-24B/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. INSTALLATION Plugs into prewired connectors. HM-2-4B requires two HM-10P HM-2-4B/K2 requires eight HM-4P HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. IMPORTANT NOTE: Backbox to be installed rotated 90 degrees for proper panel orientation. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-2-4B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-2-4B - HM-2-4B/K2 EIGHT BUTTON SWITCH PANEL The wall recessed or surface mounted HM-2-4B Eight Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with eight combination pushbuttons and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-2-4B shall contain eight momentary normally-open SPST switches; the HM-2-4B/K2 shall contain eight latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied by others. Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM2-4B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TEN BUTTON SWITCH PANEL HM-2-5B, HM-2-5B/K2 H M 2 5 B Illuminated Push-buttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted ten button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Ten combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. H M 2 5 B / K 2 INSTALLATION Plugs into prewired connectors. HM-2-5B requires two HM-12P HM-2B/K2 requires ten HM-4P HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high; Backbox: 5-3/4" (14.6cm) wide by 4" (10.16) high electrical backbox with three gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. SWITCHES Switches are normally-open, single-pole / single throw. HM-2-5B is momentary operation, HM-25B/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM2-5B Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-2-5B - HM2-5B/K2 TEN BUTTON SWITCH PANEL The wall recessed or surface mounted HM-2-5B / HM-2-5B/K2 Ten Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with ten combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-2-5B shall contain ten momentary normally-open SPST switches; the HM-2-5B/K2 shall contain ten latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a three gang box with a three gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high; Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm) high electrical backbox with three gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM2-5B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TWENTY BUTTON SWITCH PANEL HM-A20PB, HM-A20PB/K2 H M A 2 0 P B Illuminated Push-buttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connectors HM-A20PB, HM-A20PB/K2 DESCRIPTION Wall recessed or surface mounted twenty button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Twenty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. H M A 2 0 P B / K 2 INSTALLATION Plugs into prewired connectors. HM-A20PB requires four HM-12P. HM-A20PB/K2 requires twenty HM-4P. Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2" deep. SWITCHES Switches are normally-open, single-pole / single throw. HM-A20PB is momentary operation, HMA20PB/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A20PB Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A20PB, HM-A20PB/K2 TWENTY BUTTON SWITCH PANEL The wall recessed or surface mounted HM-A20PB / HM-A20PB/K2 Twenty Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with twenty combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-A20PB shall contain twenty momentary normally-open SPST switches; the HM-A20PB/K2 shall contain twenty latching normally-open SPST switches. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A20PB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICA TIONS SPECIFICATIONS THIRTY BUTTON SWITCH PANEL HM-A30PB, HM-A30PB/K2 3 0 P B / K 2 Illuminated Push-button Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation 3 0 P B Connections via Prewired Connectors Front Rear DESCRIPTION INSTALLATION Wall recessed or surface mounted thirty button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. Plugs into prewired connectors. HM-A30PB requires six HM-12P HM-A30PB/K2 requires thirty HM-4P Mounts onto backbox with four 6-32 x 1" nylon screws provided. CONTROLS AND INDICATORS Thirty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2" deep. SWITCHES Switches are normally-open, single-pole / single throw. HM-A30PB is momentary operation, HM-A30PB/K2 is latching (push-on / push-off). All switches are rated 1A / 125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A30PB Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS THIRTY BUTTON SWITCH PANEL The wall recessed or surface mounted HM-A30PB / HM-A30PB/K2 Thirty Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with thirty combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-A30PB shall contain thirty momentary normally-open SPST switches; the HM-A30PB/K2 shall contain thirty latching normally-open SPST switches. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A30PB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FORTY BUTTON SWITCH PANEL HM-A40PB, HM-A40PB/K2 H M A 4 0 P B Illuminated Push-buttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connectors HM-A40PB, HM-A40PB/K2 DESCRIPTION Wall recessed or surface mounted forty button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Forty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. H M A 4 0 P B / K 2 INSTALLATION Plugs into prewired connectors. HM-A40PB requires eight HM-12P HM-A40PB/K2 requires forty HM-4P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2" deep. SWITCHES Switches are normally-open, single-pole / single throw. HM-A40PB is momentary operation, HMA40PB/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 12/02 HM-A40PB Issue A Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS HM-40PB, HM-40PB/K2 FORTY BUTTON SWITCH PANEL The wall recessed or surface mounted HM-A40PB / HM-A40PB/K2 Forty Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with forty combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-A40PB shall contain forty momentary normally-open SPST switches; the HM-A40PB/K2 shall contain forty latching normally-open SPST switches. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A40PB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FIFTY BUTTON SWITCH PANEL HM-A50PB, HM-A50PB/K2 H M A 5 0 P B Illuminated Push-buttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connectors HM-A50PB, HM-A50PB/K2 DESCRIPTION Wall recessed or surface mounted fifty button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Fifty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. H M A 5 0 P B / K 2 INSTALLATION Plugs into prewired connectors. HM-A50PB requires ten HM-12P HM-A50PB/K2 requires fifty HM-4P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2" deep. SWITCHES Switches are normally-open, single-pole / single throw. HM-A50PB is momentary operation, HMA50PB/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A50PB Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A50PB, HM-A50PB/K2 FIFTY BUTTON SWITCH PANEL The wall recessed or surface mounted HM-A50PB / HM-A50PB/K2 Fifty Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with fifty combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-A50PB shall contain fifty momentary normally-open SPST switches; the HM-A50PB/K2 shall contain fifty latching normally-open SPST switches. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A50PB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS SIXTY BUTTON SWITCH PANEL HM-A60PB, HM-A60PB/K2 H M A 6 0 P B Illuminated Push-buttons Two Switch Configurations Available Variety of Lens Colors Available Displays System Status/Feature Activation Connections via Prewired Connectors HM-A60PB, HM-A60PB/K2 DESCRIPTION Wall recessed or surface mounted sixty button switch panel with facilities for feature activation and/or system status display. Momentary or latching switches are available. CONTROLS AND INDICATORS Sixty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. H M A 6 0 P B / K 2 INSTALLATION Plugs into prewired connectors. HM-A60PB requires twenty HM-8P HM-A60PB/K2 requires sixty HM-4P. Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2" deep. SWITCHES Switches are normally-open, single-pole / single throw. HM-A60PB is momentary operation, HM-A60PB/K2 is latching (push-on / push-off). All switches are rated 1A /125 VAC. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A60PB Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS HM-60PB , HM-60PB/K2 SIXTY BUTTON SWITCH PANEL The wall recessed or surface mounted HM-A60PB / HM-A60PB/K2 Sixty Button Switch Panel shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation. Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation and/or overall system status. The button panel shall be provided with sixty combination push-button and lamp indicators. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-A60PB shall contain sixty momentary normally-open SPST switches; the HM-A60PB/K2 shall contain sixty latching normally-open SPST switches. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A60PB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS ONE POSITION DOME LIGHT HM-D1 MAXIMUM VISIBILITY 7 LENS COLORS AVAILABLE PLUG IN LENSES FLEXIBLE INSTALLATION Front Rear Side DESCRIPTION HOUSING AND FINISH Surface, wall or ceiling mounted dome lamp. Consists of a faceplate with combination lamp socket and lens holder. Lens colors available (white, green, red, blue, amber, yellow or clear). Faceplate: Punched aluminum faceplate with baked epoxy finish, finished in off-white and supplied with nylon mounting screws. CONTROLS AND INDICATORS Low-power high-luminous lamp, front replaceable with rated average life of 6000 hours. INDICATOR CONFIGURATIONS HM-D1 provides indicators only. LAMP 28V at 40ma. 28ESB T-2 slide base. INSTALLATION DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-D1 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Prewired connectors. Mount using only the two 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-D1 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-D1 ONE POSITION DOME LIGHT The wall recessed or surface mounted Model HM-D1 One Lamp Dome Panel shall provide visual indication for system status via indicators. The HM-D1 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable with an average life of 6000 hours. Lens colors shall be available (separately). The EX-D1 shall be feature indicator only. The faceplate shall be 1/16, punched aluminum faceplate with baked epoxy, finished in off-white and supplied with nylon mounting screws. The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished. The unit shall be prewired for ease of installation. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-D1 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TWO POSITION DOME LIGHT HM-D2 MAXIMUM VISIBILITY 7 LENS COLORS AVAILABLE PLUG IN LENSES FLEXIBLE INSTALLATION Front Rear Side DESCRIPTION HOUSING AND FINISH Surface, wall or ceiling mounted dome lamp. Consists of a faceplate with combination lamp socket and lens holder. Lens colors available (white, green, red, blue, amber, yellow or clear). Faceplate: Punched aluminum faceplate with baked epoxy finish, finished in off-white and supplied with nylon mounting screws. CONTROLS AND INDICATORS Low-power high-luminous lamp, front replaceable with rated average life of 6000 hours. INDICATOR CONFIGURATIONS HM-D2 provides indicators only. LAMPS 28V at 40ma. 28ESB T-2 slide base. INSTALLATION DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-D2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Prewired connectors. Mount using only the two 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 02/03 HM-D2 Issue A Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-D2 TWO POSITION DOME LIGHT The wall recessed or surface mounted Model HM-D2 Two Lamp Dome Panel shall provide visual indication for system status via indicators. The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable with an average life of 6000 hours. Lens colors shall be available (separately). The HM-D2 shall be UL and CUL listed Hopital Signaling Equipment / Nurse Call Equipment under Fille E157381. The HM-D2 shall be feature indicator only. The faceplate shall be 1/16, punched aluminum faceplate with baked epoxy, finished in off-white and supplied with nylon mounting screws. The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished. The unit shall be prewired for ease of installation. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox - 411/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2002 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-D2 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS THREE POSITION DOME LIGHT HM-D3 MAXIMUM VISIBILITY 7 LENS COLORS AVAILABLE PLUG IN LENSES FLEXIBLE INSTALLATION Front Rear Side DESCRIPTION HOUSING AND FINISH Surface, wall or ceiling mounted dome lamp. Consists of a faceplate with combination lamp socket and lens holder. Lens colors available (white, green, red, blue, amber, yellow or clear). Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. CONTROLS AND INDICATORS Low-power high-luminous lamps, front replaceable with rated average life of 6000 hours. INDICATOR CONFIGURATIONS HM-D3 provides indicators only. LAMPS 28V at 40ma. 28ESB T-2 slide base. INSTALLATION DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-D3 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Prewired connectors. Mount using only the two 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-D3 Issue C Printed in U.S.A. ARCHITECTS' AND ENGINEERS' SPECIFICATIONS MODEL HM-D3 THREE POSITION DOME LIGHT The wall recessed or surface mounted Model HM-D3 Three Lamp Dome Panel shall provide visual indication for system status via indicators. The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable with an average life of 6000 hours. Lens colors shall be available (separately). The HM-D3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-D3 shall be feature indicator only. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished. The unit shall be prewired for ease of installation. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox - 411/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-D3 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FOUR POSITION DOME LIGHT HM-D4 MAXIMUM VISIBILITY 7 LENS COLORS AVAILABLE PLUG IN LENSES FLEXIBLE INSTALLATION Front Rear DESCRIPTION HOUSING AND FINISH Surface, wall or ceiling mounted dome lamp. Consists of a faceplate with combination lamp socket and lens holder. Lens colors available (white, green, red, blue, amber, yellow or clear). Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white supplied with nylon mounting screws; W42 Backbox: metal backbox supplied by others. CONTROLS AND INDICATORS Low-power high-luminous lamps, front replaceable with rated average life of 6000 hours. INDICATOR CONFIGURATIONS HM-D4 provides indicators only. LAMPS DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. 28V at 40ma. 28ESB T-2 slide base. LISTINGS INSTALLATION The HM-D4 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Prewired connectors. Mount using only the four 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 11/07 HM-D4 Issue C Printed in U.S.A. ARCHITECTS' AND ENGINEERS' SPECIFICATIONS MODEL HM-D4 FOUR POSITION DOME LIGHT The wall recessed or surface mounted Model HM-D4 Four Lamp Dome Panel shall provide visual indication for system status via indicators. The HM-D4 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable with an average life of 6000 hours. Lens colors shall be available (separately). The HM-D4 shall be feature indicator only. Faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. The dome light panel shall mount onto a backbox or surface housing with four nylon screws furnished. The unit shall be prewired for ease of installation. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Dome Light panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-D4 Issue C Design and Specifications subject to change without notice. HM-A10 Side Rear Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors TEN LAMP ANNUNCIATOR PANEL Front TECHNICAL SPECIFICATIONS DESCRIPTION Wall recessed or surface mounted ten lamp call annunciator panel providing visual system status indication via ten lamp positions. INDICATORS Ten low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-A10 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. INSTALLATION Plugs into prewired connectors. HM-A10 requires one HM-11P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high. Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm) high electrical backbox with three gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A10 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A10 TEN POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A10 Ten Position Annunciator Panel shall provide visual status indication via 10 lamp positions. The panel shall provide ten low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The HM-A10 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a three gang box with a three gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high; Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm) high electrical backbox with three gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A10 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TWENTY LAMP ANNUNCIATOR PANEL HM-A20 Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted twenty lamp call annunciator panel providing visual system status indication via twenty lamp positions. INDICATORS Twenty low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-A20 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Rear INSTALLATION Plugs into prewired connectors. HM-A20 requires two HM-11P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Punched aluminum faceplate with baked epoxy finish, finished in off-white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) wide x 10" (25.4cm) high x 3 1/2" (8.89 cm) deep, available separately from Heritage. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A20 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A20 TWENTY POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A20 Twenty Position Annunciator Panel shall provide visual status indication via 20 lamp positions. The panel shall provide twenty low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The HM-A20 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the annunciator panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A20 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS THIRTY LAMP ANNUNCIATOR PANEL HM-A30 Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted thirty lamp call annunciator panel providing visual system status indication via thirty lamp positions. INDICATORS Thirty low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-A30 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Rear INSTALLATION Plugs into prewired connectors. HM-A30 requires three HM-11P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) wide x 10" (25.4cm) high x 3 1/2" (8.89 cm) deep, available separately from Heritage. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A30 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A30 THIRTY POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A30 Thirty Position Annunciator Panel shall provide visual status indication via 30 lamp positions. The panel shall provide thirty low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The HM-A30 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the annunciator panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A30 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FORTY LAMP ANNUNCIATOR PANEL HM-A40 Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted forty lamp call annunciator panel providing visual system status indication via forty lamp positions. INDICATORS Forty low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-A40 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Rear INSTALLATION Plugs into prewired connectors. HM-A40 requires four HM-11P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) wide x 10" (25.4cm) high x 3 1/2" (8.89 cm) deep, available separately from Heritage. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A40 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A40 FORTY POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A40 Forty Position Annunciator Panel shall provide visual status indication via 40 lamp positions. The panel shall provide forty low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The HM-A40 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the annunciator panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A40 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FIFTY LAMP ANNUNCIATOR PANEL HM-A50 Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted fifty lamp call annunciator panel providing visual system status indication via fifty lamp positions. INDICATORS Fifty low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-50 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Rear INSTALLATION Plugs into prewired connectors. HM-A50 requires five HM-11P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) wide x 10" (25.4cm) high x 3 1/2" (8.89 cm) deep, available separately from Heritage. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A50 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A50 FIFTY POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A50 Fifty Position Annunciator Panel shall provide visual status indication via 50 lamp positions. The panel shall provide fifty low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The HM-50 shall be UL and CUL llisted Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the annunciator panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A50 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS SIXTY LAMP ANNUNCIATOR PANEL HM-A60 Displays System Status Low-Power High-Visibility Lamps Variety of Lens Colors Available Connections via Prewired Connectors Front DESCRIPTION Wall recessed or surface mounted sixty lamp call annunciator panel providing visual system status indication via sixty lamp positions. INDICATORS Sixty low-power high visibility lamps. Standard lens color is white, others available separately include: red, amber, green, blue, yellow and clear. Custom laminated labels are available for lenses. Lamps are rated 24 VDC at 40 mA. Lamps are front replaceable with rated average life of 6000 hours. LISTINGS The HM-60 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Rear INSTALLATION Plugs into prewired connectors. HM-A60 requires five HM-13P Mounts onto backbox with four 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: punched aluminum faceplate with baked epoxy finish, finished in off white. DIMENSIONS Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high. W2 Backbox: 7-1/2” (19.05cm) wide x 10" (25.4cm) high x 3 1/2" (8.89 cm) deep, available separately from Heritage. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-A60 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-A60 SIXTY POSITION ANNUNCIATOR PANEL The wall recessed or surface mounted HM-A60 Sixty Position Annunciator Panel shall provide visual status indication via 60 lamp positions. The HM-60 shall be UL and CUL llisted Hospital Signaling Equipment. Nurse Call Equipment under File E157381. The panel shall provide sixty low-power high-visibility indicator lamps. Lamps shall be front panel replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens colors available separately shall be red, amber, green, blue, yellow, and clear. The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the annunciator panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided. Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-A60 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS W2 BACK BOX HM-W2BB Steel Back Box for A20 - A60 Annunciators Steel Back Box for A20PB- A60PB Switch Panels DESCRIPTION Mill finished steel back-box for flush mounting Heritage MedCall A20 - A60 Annuciator Lamp Panels, and A20PB - A60PB Push-button Panels. CONNECTIONS Top, bottom and sides of the back-box are predrilled for connection to 1" conduit fittings. ENCLOSURE Rugged sheet metal back box for secure flush mounting of Heritage annunciator / lamp panels. INSTALLATION Mount securely to a wall stud by drilling appropriate holes for suitable fasteners. Mount horizontally or vertically as determined by orientation of annunciator plate. Make sure when mounting that consideration is given to the thickness of the wall material being used for placement of the back box. Connect conduit to back box per code. Make sure all burrs and sharp edges are removed. Use provided speed-nut fasteners for mounting face panel. HOUSING AND FINISH Mill finished steel back box. DIMENSIONS 7 1/2" (19.1cm) wide x 10 1/8" (25.7cm) high x 3" (7.6cm) deep. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-W2BB Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-W2BB BACK BOX The flush mount back box will be the method for flush mounting Heritage MedCall A20 - A60 and A20PB - A60PB annunciator / push-button panels. The back box will be mounted as shown on the plans and will be oriented as dictated by the desired orientation of the annunciator / push-button panels. Openings in the back box which are not used for attachment of conduit will be plugged by suitable means, per code. All burrs and sharp edges will be removed prior to pulling wire into the back box. Maximum dimensions on the card cage shall be: 7 1/2" (19.1cm) wide x 10 1/8" (25.7cm) high x 3" (7.6cm) deep. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-W2BB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS DESKTOP ANNUNCIATOR CONSOLE HM-DAC All sides laminated 3/4' Particle Board Pre-Drilled Hole for Cable Pre-Drilled Hole for Tone Unit DESCRIPTION HM-DAC Desktop Annunciator Console provides a desktop mounting option for A-20(PB) through A-60(PB). DIMENSIONS 8.75" W X 6" H X 10.5" L Contact Heritage for other special order sizes. HOUSING 3/4" particle board laminated on all sides in off white color. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 05/06 HM-DAC Issue C Printed in U.S.A. TECHNICAL SPECIFICATIONS PRE-WIRED CONNECTORS HM-4P,HM-6P,HM-8P,HM-10P, HM-11P,HM-12P,HM-13P Single In-line Polarized Connector Color Coded Tined Leads 22 Gauge Wire 0.10" Center Nylon Connector Housing HM-4P HM-6P HM-8P HM-10P HM-11P HM-12P HM-13P DESCRIPTION INSULATION Connectors used in the Heritage Visual Nurse Call Systems (VNS) and CliniComm Systems for push button panels and annunciator panels. Color coded semi-rigid PVC insulation. Maximum thickness .41mm. CONNECTOR GAUGE AND TYPE Single in-line polarized nylon connector. 22 gauge stranded copper wire with tinned leads. Rated temperature: 80º C Rated voltage: 300 volts UL listed style 1007 wire. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 Connectors Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-4P, HM-6P, HM-8P, HM-10P, HM-11P, HM-12P, HM-13P The HM-##P connectors shall be used in the Heritage Medcall Visual Nurse Call Systems (VNS) and the CliniComm Systems for push button panels and annunciator panels to aid in installation. The wire shall be of 22 gauge stranded copper wire with tinned leads with a rated temperature of 80º C and a voltage rating of 300 volts and UL listed 1007. Insulation shall be color coded semi-rigid PVC insulation with a maximum thickness of .41mm. Connector shall be nylon single in-line polarized connector. © 2004Heritage MedCall, Inc. Printed in U.S.A. 01/04 Connectors Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS EMERGENCY CALL SWITCH HM-1B/K2 (Emergency) Illuminated Pushbutton Silk-Screened Labeled Emergency Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted one button switch panel with silk-screened Emergency Label. Latching switch. CONTROLS AND INDICATORS One combination pushbutton and lamp indicator. Standard lens color is red, others available separately include white, amber, green, blue, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are front replaceable with rated average life of 6000 hours. SWITCH Switch is normally-open, single-pole / single throw. HM-1B/K2 (EMERGENCY) is latching (push-on / push-off). All switches are rated 1A / 125 VAC. Rear Side INSTALLATION Plugs into prewired connectors. HM-ESC requires one HM-4P Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-1B/K2 (EMERGENCY) is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 04/03 HM-1B/K2 (EMERGENCY) Issue A Printed in U.S.A. Architects’ and Engineers’ Specifications Model HM-1B/K2 (EMERGENCY) Emergency Call Switch The wall recessed or surface mounted HM-1B/K2 (EMERGENCY) Emergency Call Switch shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push button shall be used for feature activation. Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature activation and/or overall system status. The HM-1B/K2 (EMERGENCY) shall be silk-screened labeled with the words "EMERGENCY CALL" in bold red lettering. The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-1B/K2 (EMERGENCY) shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-1B/K2 (EMERGENCY) shall contain one latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2002 Heritage MedCall, Inc. Printed in U.S.A. 04/03 HM-1B/K2 (EMERGENCY) Issue A Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS CODE BLUE CALL SWITCH HM-1B/K2 (Code Blue) Illuminated Pushbutton Silk-Screened Labeled Code Blue Connections via Prewired Connector Front DESCRIPTION Wall recessed or surface mounted one button switch panel with silk-screened Code Blue Label. Latching switch. CONTROLS AND INDICATORS One combination pushbutton and lamp indicator. Standard lens color is blue others available separately include white, amber, green, red, yellow, clear, and black. Custom laminated labels are available for lenses. Lamps are front replaceable with rated average life of 6000 hours. SWITCH Switch is normally-open, single-pole / single throw. HM-1B/K2 (CODE BLUE) is latching (push-on / push-off). All switches are rated 1A / 125 VAC. Rear Side INSTALLATION Plugs into prewired connectors. HM-1B/K2 (CODE BLUE) requires one HM-4P Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-1B/K2 (CODE BLUE) is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-1B/K2 (CODE BLUE) Issue C Printed in U.S.A. Architects’ and Engineers’ Specifications Model HM-1B/K2 (CODE BLUE), CODE BLUE SWITCH The wall recessed or surface mounted HM-1B/K2 (CODE BLUE) Code Blue Emergency Switch shall be available for use as a system feature input device as well as a status indicator. Feature Input Device - As a system feature input device, the push button shall be used for feature activation. Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature activation and/or overall system status. The HM-1B/K2 (CODE BLUE) shall be silk-screened labeled with the words "CODE BLUE" in bold blue lettering. The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours. The HM-1B/K2 (CODE BLUE) shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-1B/K2 (CODE BLUE) shall contain one latching normally-open SPST switches. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of installation, the button panel shall plug into pre-wired connectors. Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided. Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting. The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-1B/K2 (CODE BLUE) Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICA TIONS SPECIFICATIONS 24 VOLT 2.5A POWER SUPPLY HM-24V-2.5A Low Profile Lightweight Single Output Global Safety Agency Compliance Low Conducted EMI DESCRIPTION Single output regulated DC power supply rated for 24 volts at 2.5 amps. OUTPUT PROTECTION Current limiting and overvoltage crowbar protected, auto restart. ENVIRONMENTAL REQUIREMENTS Operating Temperature: 0ºC to 40ºC (32ºC to 104ºF) Storage Temperature: -40ºC to 70ºC (-40ºF to 158ºF) POWER REQUIREMENTS Input voltage range 90-264VAC, 47- 63 hz maximum 27A. HOOKUP Prewired connector. OUTPUT Voltage: nominal 24 volts DC ± 720mV. Current: Up to 2.5 Amps. Ripple and Noise: Maximum 240mV. LINE CORD Heavy duty six foot (1.83m) terminated with molded three-prong plug. HOUSING ABS plastic black casing. DIMENSIONS Maximum dimensions are 5.14" L (130.5mm ) x 2.72" W (69 mm) x 1.57" H (40 mm). Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com Printed in U.S.A. 01/04 HM-24V-2.5A Issue C ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-24V-2.5A POWER SUPPLY 24 VOLT 2.5 AMP The HM-24V-2.5A power supply shall provide a regulated DC single output rated for 24 volts at 2.5 amps maximum. The power supply shall contain overloading, short circuit, and overvoltage protection. The power supply shall be designed for a long life of continuous duty operation. Operating temperature shall be 0ºC to 40ºC (32ºC to 104ºF). Storage temperature shall be -40ºC to 70ºC (-40ºF to 158ºF). The input power requirements shall be 90 to 264 VAC at 47 to 63 hz maximum 27 amps. The output voltage shall be nominal 24 volts DC ±720mV up to 2.5 amps. Ripple and noise shall be maximum 240 mV. The output shall be floating with respect to ground. A heavy duty six-foot (1.83m) line cord terminated with molded three-prong plug shall be provided for input connections. The output connection shall be prewired molded connector. The power supply shall be housed in ABS plastic. The housing maximum dimensions shall be 5.14" L (130.5mm ) x 2.72" W (69 mm) x 1.57" H (40 mm). © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-24V-2.5A Issue Design and Specifications subject to change without notice. C TECHNICAL SPECIFICA TIONS SPECIFICATIONS 5 VOLT 10A POWER SUPPLY HM-5V-10A Low Profile Lightweight Single Output Global Safety Agency Compliance Low Conducted EMI DESCRIPTION Single output regulated DC power supply rated for 5 volts at 10 amps. OUTPUT PROTECTION Current limiting and overvoltage crowbar protected, auto restart. ENVIRONMENTAL REQUIREMENTS Operating Temperature: 0ºC to 40ºC (32ºC to 104ºF) Storage Temperature: -40ºC to 70ºC (-40ºF to 158ºF) HOOKUP Prewired connector. POWER REQUIREMENTS Input voltage range 90-264VAC, 47- 63 hz maximum 27A. OUTPUT Voltage: nominal 5 volts DC ± 250mV. Current: Up to 10 Amps. Ripple and Noise: Maximum 50mV peak to peak Power: 50 Watts Maximum. LINE CORD Heavy duty six foot (1.83m) terminated with molded three-prong plug. HOUSING ABS plastic black casing. DIMENSIONS Maximum dimensions are 6.06" L (154mm) x 3.35" W (85mm) x 2.09" H (53mm). Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-5V-10A Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-5V-10A POWER SUPPLY 5 VOLT 10 AMP The HM-5V-10A power supply shall provide a regulated DC single output rated for 5 volts at 10 amps maximum. The power supply shall contain overloading, short circuit, and overvoltage protection. The power supply shall be designed for a long life of continuous duty operation. Operating temperature shall be 0ºC to 40ºC (32ºC to 104ºF). Storage temperature shall be -40ºC to 70ºC (-40ºF to 158ºF). The input power requirements shall be 90 to 264 VAC at 47 to 63 hz maximum 27 amps. The output voltage shall be nominal 5 volts DC ±250mV up to 10 amps. Ripple and noise shall be maximum 50 mV. The output shall be floating with respect to ground. A heavy duty six-foot (1.83m) line cord terminated with molded three-prong plug shall be provided for input connections. The output connection shall be prewired molded connector. The power supply shall be housed in ABS plastic. The housing maximum dimensions shall be 6.06" L (154mm) x 3.35" W (85mm) x 2.09" H (53mm). © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-5V-10A Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS DUTY STATION HM-DUTY Visual/Audio Patient Call Indication Interrupted Tone Signal for Emergency Call Differentiation of Type of Call Placed UL Listed Front Rear Side DESCRIPTION Wall recessed or surface mounted duty station provides visual and audible indication of normal and emergency calls placed. INSTALLATION Color-coded prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided CONTROLS AND INDICATORS One white call indicator. Tone signals announce incoming calls. Repeating tone signals announce unanswered calls. Interrupted tone signals indicate emergency calls. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. CIRCUITRY Solid state circuitry; long-life indicator lamps and front adjustable tone module for volume adjustment. LISTINGS The HM-DUTY is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-DUTY Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-DUTY DUTY STATION The wall recessed or surface mounted duty station shall provide visual and audible indication of normal and emergency calls placed. Tone signals shall announce incoming calls. Repeating tone signals shall announce unanswered calls. Interrupted tone signals shall indicate emergency calls. The unit shall be provided with one white call indicator and adjustable tone module for tone volume adjustment. To insure long life and reliability, solid state signal circuitry with long-life indicator lamps shall be used. The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be provided to mount the faceplate. The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-Duty Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS CENTRAL TONE UNIT HM-CTU Provides Audible Indication Adjustable Volume Settings Flame Retardant Faceplate Minimum Wiring for Easy Installation Front DESCRIPTION Wall recessed or surface mounted central tone unit provides audible indication of system status / feature activation. CONTROLS AND INDICATORS Tone signals indicate feature activation via adjustable tone module. CIRCUITRY Solid state circuitry, front adjustable tone module for volume adjustment provides variable attenuation up to 20dB typical. Tone: 93 db at 2 feet. Rear HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O, finished in off-white supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. INSTALLATION Color-coded prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-CTU Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-CTU CENTRAL TONE UNIT The wall recessed or surface mounted tone module shall provide audible indication of system status and/or feature activation. Tone signals shall indicate system status/feature activation via the adjustable tone module. The unit shall be provided with an adjustable tone shutter for tone volume adjustment. To insure long life and reliability, solid state signal circuitry shall be used. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be provided to mount the faceplate. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-CTU Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS CENTRAL TONE UNIT / RING HM-CTU/R Provides Audible Indication Adjustable Volume Settings Distinctive Ring Tone Flame Retardant Faceplate Minimum Wiring for Easy Installation Front DESCRIPTION Wall recessed or surface mounted central tone unit with distinctive ring tone to provide audible indication of system status / feature activation. CONTROLS AND INDICATORS Tone signals indicate feature activation via adjustable tone module. CIRCUITRY Solid state circuitry, front adjustable tone module for volume adjustment provides variable attenuation up to 20dB typical. Tone: 93 db at 2 feet. Rear HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O, finished in off-white supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. INSTALLATION Color-coded prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 07/04 HM-CTU/R Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-CTU CENTRAL TONE UNIT / RING The wall recessed or surface mounted tone module shall provide audible indication of system status and/or feature activation. Tone signals shall indicate system status/feature activation via the adjustable tone module. The unit shall be provided with an adjustable tone shutter for tone volume adjustment. To insure long life and reliability, solid state signal circuitry shall be used. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be provided to mount the faceplate. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 07/04 HM-CTU/R Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS TONE CONTROL UNIT HM-CTU/TCU Provides Audible Patient Call Indication Interrupted Tone Signal for Emergency Call Differentiation of Type of Call Placed UL Listed Front Rear Side DESCRIPTION Wall recessed or surface mounted tone module provides audible indication of normal and emergency calls placed. INSTALLATION Color-coded prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided. CONTROLS AND INDICATORS Tone signals announce incoming calls. Repeating tone signals announce unanswered calls. Interrupted tone signals indicate emergency calls. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. CIRCUITRY Solid state circuitry, front adjustable tone module for volume adjustment. LISTINGS The HM-CTU/TCU is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-CTU/TCU Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-CTU/TCU TONE CONTROL UNIT The wall recessed or surface mounted tone module shall provide audible indication of normal and emergency calls placed. Tone signals shall announce incoming calls. Repeating tone signals shall announce unanswered calls. Interrupted tone signals shall indicate emergency calls. The unit shall be provided with one adjustable tone module for tone volume adjustment. To insure long life and reliability, solid state signal circuitry shall be used. The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL. Nylon screws shall be provided to mount the faceplate. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical backbox with onegang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-CTU/TCU Issue Design and Specifications subject to change without notice. C TECHNICAL SPECIFICATIONS TOILET EMERGENCY SWITCH HM-TES "PULL FOR HELP" Screened in Red On Faceplate Positive Action Switch High Luminosity Red LED Call Indicator Adjustable Nylon Cord Large Red Tassel Front DESCRIPTION Wall recessed or surface mounted Emergency Call Station with red LED call indicator and six foot pull cord and large red tassel. CONTROLS AND INDICATORS When the call is placed using pull-cord activation, the unit shall provide visual indication of emergency call placement by flashing a red lamp with 60 IPM (interruptions per minute) until call is manually canceled by resetting the switch to the inactive position. SWITCH Switches are positive action double pole, double throw slide switch with distinctive red position locator and reset knob. Rear INSTALLATION Prewired with provided 6" color coded stranded wires stripped 3/8" for ease of installation and interconnections to the unit Mount using only the two 6-32 x 1" nylon screws provided. HOUSING AND FINISH Faceplate: Standard single gang beveled edge molded white ABS, supplied with nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. ELECTRICAL CHARACTERISTICS Operating Voltage: 28VDC Current, Idle: None Current, Operating: 25 MilliAmperes @28vdc (excluding external lamps and / or circuits). Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-TES Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-TES TOILET EMERGENCY SWITCH The HM-TES shall be a wall recessed or surface mounted Emergency Call Station with red LED call indicator and six foot pull cord and large red tassel. When the call is placed using pull-cord activation, the unit shall provide visual indication of emergency call placement by flashing a red lamp with 60 IPM (interruptions per minute) until call is manually canceled by resetting the switch to the inactive position. Switch shall be positive action double pole, double throw slide switch with distinctive red position locator and reset knob. Operating voltage shall be 28VDC with an maximum current draw in alarm mode at 23 mA The HM-TES shall be prewired with the provided 6" color coded stranded wires stripped 3/8" for ease of installation and interconnections to the unit. Mount using only the two 6-32 x 1" nylon screws provided.. Faceplate shall be standard single gang beveled edge molded white ABS, supplied with nylon mounting screws. Dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/ 16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM3B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS SINGLE PATIENT STATION HM-SPS Call Placement Indicator Call Reset Button Cordset Removal Triggers Call Placement Standard Cordset Receptacle UL Listed Front DESCRIPTION Wall recessed or surface mounted single patient station for use with remote call origination cordset. Removal of the cordset originates a call placement. RECEPTACLE One cordset receptacle wired to accept a single 1/4" cordset (normal call, geriatric, explosion proof) with nurse call origination facility. CONTROLS AND INDICATORS One combination white call placement indicator and call cancel button. INSTALLATION Color-coded, prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided. Rear Side HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-SPS is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-SPS Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-SPS SINGLE PATIENT STATION The wall recessed or surface mounted single patient station shall be for use with remote call origination cordset. The patient station shall be provided with a white combination call placement indicator and call cancel button. A receptacle shall be provided, to accept single 1/4" type cordsets. A call shall be originated if the cordset is removed from the receptacle. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL. Nylon Screws shall be provided to mount the faceplate. The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-SPS Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS DUAL PATIENT STATION HM-DPS Call Placement Indicator Call Reset Button Cordset Removal Triggers Call Placement Standard Cordset Receptacle UL Listed Front DESCRIPTION Wall recessed or surface mounted dual patient station with individual cordset receptacles for use with remote call origination cordset. Removal of either cordset originates a call placement. RECEPTACLES Two cordset receptacles wired to accept 1/4" cordsets (normal call, geriatric, explosion proof) with nurse call origination facility. CONTROLS AND INDICATORS One combination white call placement indicator and call cancel button. INSTALLATION Color-coded, prewired terminations provided. Mount using only the two 6-32 x 1" nylon screws provided. Rear Side HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white supplied with nylon mounting screws. W41 Backbox: metal backbox supplied by others. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for a total depth of 2-7/8” (7.30cm), supplied by others. LISTINGS The HM-DPS is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com Printed in U.S.A. 01/04 HM-DPS Issue C ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-DPS DUAL PATIENT STATION The wall recessed or surface mounted dual patient station shall be for use with two remote call origination cordsets. The patient station shall be provided with a white combination call placement indicator and call cancel button. Two receptacles shall be provided to accept two 1/4" type cordsets. A call shall be originated if either cordset is removed from the receptacles. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be flame retardant ABS plastic rated 94V-O by UL. Nylon screws shall be provided to mount the faceplate. The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-DPS Issue C Design and Specifications subject to change without notice. DUAL PATIENT STATION TECHNICAL SPECIFICA TIONS SPECIFICATIONS HM-DPS/2GA Individual Call Placement Indicators Individual Call Reset Buttons Cordset Removal Triggers Call Placement Standard Cordset Receptacles UL Listed Front Rear Side DESCRIPTION Wall recessed or surface mounted dual patient station with individual cordset receptacles and call indicators for use with remote call origination cordset. Removal of either cordset originates a call placement. HOUSING AND FINISH Faceplate: Flame retardant ABS plastic rated 94V-O by UL, finished in off-white supplied with nylon mounting screws. W42 Backbox: metal backbox supplied by others. RECEPTACLES Two cordset receptacles wired to accept 1/4" cordsets (normal call, geriatric, explosion proof) with nurse call origination facility. DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high. W41 Backbox: 4-11/16” (11.91cm) square electrical box with two-gang adapter for a total depth of 3-5/16” (8.41cm), supplied by others. CONTROLS AND INDICATORS Two combination white call placement indicators and call cancel buttons. INSTALLATION Color-coded, prewired terminations provided. Mount using only the four 6-32 x 1" nylon screws provided. LISTINGS The HM-DPS/2GA is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-DPS/2GA Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-DPS/2GA DUAL PATIENT STATION The wall recessed or surface mounted dual patient station shall be for use with two remote call origination cordsets. The patient station shall be provided with two white combination call placement indicators and call cancel buttons. Two receptacles shall be provided to accept two 1/4" type cordsets. A call shall be originated if either cordset is removed from the receptacles. The unit shall be provided with color-coded prewired terminations for ease of installation. Faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be provided to mount the faceplate. The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The faceplate shall be finished in off-white. The W42 backbox shall be supplied by others. The dimensions shall be: Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high, W42 backbox: 4-11/16” (11.91cm) square electrical box with two-gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-DPS/2GA Issue C Design and Specifications subject to change without notice. Heritage MedCall Technical Specifications MODEL HM-PBCC-8 8' BED CORD 1/4" PHONO PLUG MOMENTARY OPERATION CORD CLIP FOR SECURING TO BED OR PATIENT CLOTHES EASY CLEAN FINISH DESCRIPTION: The Heritage Model HM-PBCC-8 is an 8' momentary call switch for use with the Model HM-671, HM-SPS or HM-DPS to allow call placement from a bed or chair. The Bed-Cord is fitted with a clasp for securing the cord to the bed or patient clothes. RESET: Emergency call station reset is accomplished by pressing the CHECK-IN or CANCEL button on the HM-527 or HM-S(D)PS panel. All emergency calls require this reset action to assure all calls are verified and all initiating locations are visited. INSTALLATION: Model HM-PBCC-8 is installed by fully inserting the 1/4" phone plug into the bed-cord wall plate. Removing the bed-cord from the wall plate will initiate an emergency call Heritage MedCall, Inc 202 East Virginia Avenue Tampa, Fl 33603 813-221-1000 ph 813-223-1405 fax email@heritagemedcall.com www.heritagemedcall.com TECHNICAL SPECIFICATIONS SINGLE PATIENT STATION OCTAL HM-SPS/OCT Call Placement Indicator Call Reset Button Cordset Removal Triggers Call Placement Prewired Patient Control via Octal Socket Front DESCRIPTION Wall recessed or surface mounted single patient station for use with remote call origination cordset or patient control unit for call origination and control of radio and television entertainment functions. Removal of the cordset or the patient control unit originates a call placement. RECEPTACLE Multi-purpose cordset receptacle fully wired to accept any one of the following cordsets interchangeably on a plug-in basis: a: Patient control unit with nurse call origination facility and remote control of TV and radio. b: Standard single prong combination cordset (normal call, geriatric, explosion proof) with nurse call origination facility. Rear CONTROLS AND INDICATORS One combination white call placement indicator and CANCEL button. INSTALLATION Color-coded, prewired terminations provided. HOUSING AND FINISH Faceplate: Standard 1-gang beveled edge molded ABS plastic finished in gray, supplied with non-conductive nylon mounting screws. DIMENSIONS Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high x 1-7/8" (4.76cm) deep; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-SPS/OCT Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-SPS/OCT SINGLE PATIENT STATION OCTAL The wall recessed or surface mounted single patient station shall be for use with remote call origination cordset or patient control unit. Facilities for TV and radio control shall be provided. The patient station shall be provided with a white combination call placement indicator and CANCEL button. One multi-purpose receptacle shall be provided to accept single prong type cordset or patient control unit. A call shall be originated if the cordset or the patient control unit is removed from the receptacle. The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate shall be a standard 1-gang beveled edge, molded ABS plastic finished in gray, supplied with nonconductive nylon mounting screws for maximum safety against electrical shock. The Dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high x 1-7/8" (4.76cm) deep; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM1B Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS ENTERTAINMENT CONTROL UNIT HM-ECU Allows Remote Control of TV Set Selection of Five Audio Channels Connections via Prewired Connector Compact Design DESCRIPTION Wall recessed or surface mounted Radio/TV and comfort control, used with patient control unit and patient station, for remote control of television set, bed position, room lighting, drapes and one additional function, and for selection of five radio or other audio programs. APPLICATIONS For television sets equipped for automatic adjustment of color and tint, and audio entertainment distribution system providing five program channels. POWER REQUIREMENT One Model HM-24V-2.5A Power Supply supports a combination of up to 80 radio/TV selector circuits. INSTALLATION The HM-ECU shall mount on a two-gang faceplate using a standard two-gang electrical box, supplied by others. For ease of installation and maintenance, the unit will plug into prewired connector using 1-HM-ECUP. HOUSING AND FINISH Circuit Board mounted to metal bracket on nonconductive standoffs. DIMENSIONS Maximum dimensions shall be 3-5/8" (9.2cm) wide x 3-1/8" (8 cm) deep x 1-1/2" (3.81 cm) high. LISTINGS The HM-ECU is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-226-0091 (voice), 813-228-8622 (fax) www.heritagemedcall.com 02/03 HM-ECU Issue A Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-ECU ENTERTAINMENT CONTROL UNIT The wall recessed or surface mounted radio/TV selector shall be used with patient control unit and patient station for remote control of television set and selection of five radio or other audio programs. The radio/TV selector shall operate with television sets equipped for automatic adjustment of color and tint, and an audio entertainment distribution system providing up to five program channels. The HM-ECU is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. One Model HM-24V-2.5A Power Supply shall support a combination of up to 80 radio/TV selector circuits. For ease of installation and maintenance, the unit shall plug into prewired connector. All components shall be mounted on a faceplate designed to fit into the opening of a standard two-gang electrical backbox. For maximum safety against electrical shock, the faceplate shall be mounted using nonconductive screws. The HM-ECU shall mount on a two-gang faceplate using a standard two-gang electrical box, supplied by others. For ease of installation and maintenance, the unit will plug into prewired connector using 1-HMECUP ordered separately. Maximum dimensions shall be 3-5/8" (9.2 cm) wide x 3-1/8" (8 cm) deep x 1-1/2" (3.81 cm) high. © 2002 Heritage MedCall, Inc. Printed in U.S.A. 02/03 HM-ECU Issue A Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS PRE-WIRED CONNECTORS HM-ECUP Single In-line Polarized Connector Color Coded Tined Leads 22 Gauge Wire 0.10" Center Nylon Connector Housing DESCRIPTION INSULATION Connectors used in the Heritage Visual Nurse Call Systems (VNS) for the HM-ECU Entertainment Control Unit. Color coded semi-rigid PVC insulation. Maximum thickness .41mm. GAUGE AND TYPE CONNECTOR 22 gauge stranded copper wire with tinned leads. Rated temperature: 80º C Rated voltage: 300 volts UL listed style 1007 wire. Single in-line polarized nylon connector. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-ECUP Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-ECUP PRE-WIRED CONNECTORS The HM-ECUP connectors shall be used in the Heritage Medcall Visual Nurse Call Systems (VNS) for the connection to the HM-ECU Entertainment Control Unit. The wire shall be of 22 gauge stranded copper wire with tinned leads with a rated temperature of 80º C and a voltage rating of 300 volts and UL listed 1007. Insulation shall be color coded semi-rigid PVC insulation with a maximum thickness of .41mm. Connector shall be nylon single in-line polarized connector. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-ECUP Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS EMERGENCY SWITCH COVER HM-ESC Low Profile Clear Acrylic Cover Cutout on Bottom DESCRIPTION Provides protection from inadvertent operation of emergency and code blue switches. INSTALLATION Cover attached using screw or hook and loop fasteners as appropriate. HOUSING Formed clear acrylic cover with clear acrylic hinge. Cutout on cover bottom allows clearance for pull cords or bed cords. DIMENSIONS 3.5" W (88.9mm) X 6.6" H ( 167.64mm) X 1.36" (34.54mm) standard. Contact Heritage for other special order sizes. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-ESC Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-ESC EMERGENCY SWITCH COVER The HM-ESC shall be used to provide protection from inadvertent operation of emergency and code blue calls. Housing shall be made of formed clear acrylic cover with clear acrylic hinge. Cutout on cover bottom allows clearance for pull cords or bed cords. The HM-ESC shall be attached using screw or hook and loop fasteners as appropriate. The dimensions shall be 3.5" Wide (88.9mm) X 6.6" High ( 167.64mm) X 1.36" Deep (34.54mm) standard. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-ESC Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS FLASHER UNIT HM-F3 Three Levels of Operation Terminal Block for Connections Removable Protective Cover Metal Base for Easy Wall Mounting Rugged Metal Housing Top Side DESCRIPTION Three level flasher assembly provided in a surface mounted housing. INSTALLATION Terminal block for wire connections with holes in flasher base for wall mounting. CIRCUITRY Solid state for maximum reliability. HOUSING Metal base and removable protective metal cover. OPERATING VOLTAGE 24 volts DC. No AC outlet required. OUTPUT RATING 4 Amps at 24 - 28 volts DC. FLASH RATES Three rates to annunciator panel with associated duty line: Priority High Medium Low To Annunciator Duty Line 60 Pulses Per Min. (PPM) 60 PPM 30 PPM 30 PPM Steady 6 PPM FINISH Metal cover finished in black. DIMENSIONS 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 113/16” (4.60cm) deep. LISTINGS The HM-DPS/2GA is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-F3 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-F3 FLASHER UNIT The three level flasher shall consist of solid state circuitry in a surface mounted housing. The flasher shall operate on 24-28 volts DC and shall not require an AC outlet. The flasher output rating shall be 4 amps at 24-28 volts DC. The HM-F3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The flasher unit shall provide three output rates to the annunciator panel, and associated duty line. The three rates are: Priority High Medium Low © 2004 Heritage MedCall, Inc. To Annunciator 60 Pulses Per Min. (PPM) 30 PPM Steady Printed in U.S.A. Duty Line 60 PPM 30 PPM 6 PPM 01/04 HM-F3 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS LAMP AND TONE CONTROL UNIT HM-T1 Single Level Call Terminal Block for Connections Removable Protective Cover Metal Base for Easy Wall Mounting Rugged Metal Housing DESCRIPTION Single level lamp and tone control unit for multiple call locations to provide call event activation or de-activation from any call location. TONE RATES Length: 0 - 1 seconds Rate: 1- 60 seconds CIRCUITRY Solid state for maximum reliability. INSTALLATION Terminal block for wire connections with holes in base for wall mounting. OPERATING VOLTAGE 24 volts DC. HOUSING Natural aluminum finished box 0.040 thickness. OUTPUT RATING Circuit draw 20 ma. Maximum draw 2 amps. DIMENSIONS 5.25" L X 3.0" W X 2.12" H INDICATORS Power Indication Lamp Active Tone Active Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 07/04 HM-T1 Printed in U.S.A. MODEL HM-T1 LAMP AND TONE CONTROL UNIT The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing. The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2 amps at 24-28 volts DC. The lamp and tone control unit shall have an adjustable tone duration from zero to one second. The lamp and tone control unit shall have an adjustable tone rate from one to sixty seconds. Installation shall consist of six position terminal block for wire connections and housed in a natural aluminum finished box 0.040" thickness. Dimmensions of housing shall be 5.25" L X 3.0" W X 2.12" H. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 07/04 HM-T1 Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS LAMP AND TONE CONTROL UNIT HM-T4 Four Discrete Lamp Circuits One Tone Control Circuit Terminal Block for Connections Removable Protective Cover Metal Base for Easy Wall Mounting Rugged Metal Housing DESCRIPTION The HM-T4 is a unique low cost device to control a simple light or light and tone signaling system with four discrete lamp circuits. The HM-T4 allows one or more switches to turn on and off lights from multiple locations with the use of simple lighted pushbutton switches. The HM-T4 has a circuit to drive tone units to audibly annunciate when a button is activated. The tone circuit has adjustments to vary both the length of the tone and how often it is repeated. The HM-T4 allows you to choose which circuit controls the tone units. CIRCUITRY Solid state for maximum reliability. OPERATING VOLTAGE 24 volts DC. INDICATORS Power Indication Lamp Active - (4) Tone Active TONE RATES Length: 0 - 1 seconds Repeat: 1- 60 seconds INSTALLATION Terminal block for wire connections with holes in base for wall mounting. HOUSING Metal cover finished in black. DIMENSIONS 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high 1-13/16” (4.60cm) deep. OUTPUT RATING Circuit draw 20 ma. Maximum draw 2 amps. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 08/04 HM-T4 Printed in U.S.A. MODEL HM-T4 LAMP AND TONE CONTROL UNIT The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing. The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2 amps at 24-28 volts DC. The lamp and tone control unit shall have an adjustable tone duration from zero to one second. The lamp and tone control unit shall have an adjustable tone repeat rate from one to sixty seconds. Installation shall consist of twelve position terminal block for wire connections and housed in a metal box finished in black. Dimmensions of housing shall be 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 1-13/16” (4.60cm) deep. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 08/04 HM-T4 Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS LAMP AND TONE CONTROL UNIT HM-T8 Eight Discrete Lamp Circuits One Tone Control Circuit Terminal Block for Connections Removable Protective Cover Metal Base for Easy Wall Mounting Rugged Metal Housing Link multiple HM-T8's together DESCRIPTION The HM-T8 is a unique low cost device to control a simple light or light and tone signaling system with eight discrete lamp circuits. The HM-T8 allows one or more switches to turn on and off lights from multiple locations with the use of simple lighted pushbutton switches. The HM-T8 has a circuit to drive tone units to audibly annunciate when a button is activated. The tone circuit has adjustments to vary both the length of the tone and how often it is repeated. The HM-T8 allows you to choose which circuit controls the tone units. Link multiple HM-T8 together for single tone annunciation. CIRCUITRY Solid state for maximum reliability. OPERATING VOLTAGE 24 volts DC. INDICATORS Power Indication Lamp Active - (8) Tone Active TONE RATES Length: 0 - 1 seconds Repeat: 1- 60 seconds INSTALLATION Terminal block for wire connections with holes in base for wall mounting. HOUSING Metal cover finished in black. DIMENSIONS 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high 1-13/16” (4.60cm) deep. OUTPUT RATING Circuit draw 20 ma. Maximum draw 2 amps. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 08/04 HM-T8 Printed in U.S.A. MODEL HM-T8 LAMP AND TONE CONTROL UNIT The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing. The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2 amps at 24-28 volts DC. The lamp and tone control unit shall have an adjustable tone duration from zero to one second. The lamp and tone control unit shall have an adjustable tone repeat rate from one to sixty seconds. Installation shall consist of a twenty two position terminal block for wire connections and housed in a metal box finished in black. Dimmensions of housing shall be 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 1-13/16” (4.60cm) deep. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 08/04 HM-T8 Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS ZONE CONTROL MODULE HM-ZCM3 Controls Three Separate Zone Dome Lights Responds to All Normal Calls in Zone Responds to All Emergency Calls In Zone Solid State Circuitry Mounts on Standard Two-Gang Backbox DESCRIPTION Surface or flush mounted zone light control for use in conjunction with three zone lamps. Used in locations where the nurse control station and/ or annunciator panel and specific care lights are not visible to alert the nursing personnel of calls placed by patients. Normal calls are indicated by steady illumination of a lamp. Emergency calls are indicated by flashing lamp. REQUIREMENTS One zone light control and three dome lights required for every three zones in the system. CIRCUITRY Solid state devices mounted on an epoxy glass printed circuit board. HOUSING AND FINISH Faceplate: Flame retardant ABS platic rated 94VV-O by UL, finished in off-white. W42 Backbox: Metal backbox supplied by others. DIMENSIONS Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. LISTINGS The HM-ZCM3 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. INSTALLATION Miniature terminal block with screw terminals and barriers. Heritage MedCall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-ZCM3 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-ZCM3 ZONE CONTROL MODULE The wall recessed or surface mounted zone light control shall be used in conjunction with three zone lamps in locations where the nurse control station and/or annunciator panel and specific care lights are not visible to alert nursing personnel of calls placed by patients. Normal calls shall be indicated by steady illumination of a lamp. Emergency calls shall be indicated by flashing lamp. The HM-ZCM3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File E157381. The HM-ZCM3 Zone Control Module and three zone lamps shall be required for every three zones in the system. For reliability, solid state devices and epoxy glass printed circuit board shall be used. For ease of installation and maintenance, miniature terminal block and screw terminals with barriers shall be provided. The HM-ZCM3 faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. The dimensions shall be: Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox: 4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm), supplied by others. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-ZCM3 Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS ANNUNCIATOR LAMP HM-28ESB LongLife High Visibility Low Current Draw DESCRIPTION Incandescent T-2 Telephone Slide Base Type 5 (short) Lamp. INDICATOR Mean Spherical Candle Power of 1500. Life expectancy of 6000 hours. Filament Type C-2F. ELECTRICAL CHARACTERISTICS Voltage Rating: 28 volts DC Current Draw: 45mA. DIMENSIONS 0.28” (7.112mm) wide x 0.915” (23.24mm) high Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 03/03 HM-28ESB Issue A Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-28ESB ANNUNCIATOR LAMP The HM-28ESB shall be a incandescent style T-2 Telephone Slide Base Type 5 (short) lamp. Lamp shall have a minimum rating of 1500 mscp (mean spherical candle power) and life expectancy of 6000 hours. Filament shall consist of type C-2F. The HM-28ESB shall operate at a maximium voltage of 28 volts DC at 0.45 mA. The dimensions shall be 0.28” (7.112mm) wide x 0.915” (23.24mm) high. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-28ESB Issue C Design and Specifications subject to change without notice. TECHNICAL SPECIFICATIONS PUSH BUTTON PANEL BULBS HM-85 LongLife High Visibility Low Current Draw DESCRIPTION Incandescent T-1 3/4 Wedge Base style bulb. ELECTRICAL CHARACTERISTICS Voltage Rating: 28 volts DC Current Draw: 40mA. INDICATOR Mean Spherical Candle Power of 0.300. Life expectancy of 7000 hours. Filament Type C-2F. DIMENSIONS 0.230” (5.842mm) wide x 0.800” (20.32mm) high. Heritage Medcall, Inc. 202 East Virginia Avenue, Tampa, FL 33603 813-221-1000 (voice), 813-223-1405 (fax) www.heritagemedcall.com 01/04 HM-85 Issue C Printed in U.S.A. ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS MODEL HM-85 PUSHBUTTON PANEL BULB The HM-85 shall be a incandescent style T-1 3/4 Wedge Base style bulb. Lamp shall have a minimum rating of .300 mscp (mean spherical candle power) and life expectancy of 7000 hours. Filament shall consist of type C-2F. The HM-85 shall operate at a maximum voltage of 28 volts DC at 0.40 mA. The dimensions shall be 0.230” (5.842mm) wide x 0.800” (20.32mm) high. © 2004 Heritage MedCall, Inc. Printed in U.S.A. 01/04 HM-85 Issue C Design and Specifications subject to change without notice.