VNS Spec Sheets Binder Complete

advertisement
TECHNICAL
SPECIFICATIONS
MULTI-SECTIONAL DOME LAMP
HM-DM1, HM-DM2, HM-DM3, HM-DM4
MAXIMUM VISIBILITY
FOUR LAMP COLORS
AVAILABLE
PLUG IN BULBS
FLEXIBLE INSTALLATION
Front
Rear
DESCRIPTION
HOUSING AND FINISH
The multi-sectional dome lamp, DM-1 thru DM-4,
shall be surface, wall or ceiling mounted available
for use as 1 section (single) to 4 section dome
lamp.
Faceplate: High impact molded ABS with flame
retardant properties finished in off-white.
Dome Lens: High impact translucent acrylic
with flame retardant properties finished in white
translucent.
LAMP
Bayonet type, long life incandescent lamps rated
at 100 mA at 28 volts DC each, replaceable from
the front. Available colors; white, red, green or
amber.
INSTALLATION
Prewired connectors to facilitate easy installation.
Mount using only the four 6-32 x 1" nylon screws
provided.
DIMENSIONS
Faceplate & Dome Lens: 4 ½" (11.43cm) high
x 4 9/16" (11.59cm) wide x 3" (7.62cm) deep.
W42 Backbox: 4-11/16” (11.91cm) wide square
electrical backbox with two gang adapter for total
depth of 2-7/8” (7.30cm), supplied by others.
LISTINGS
The HM-DM# is UL listed Hospital Signaling
Equipment / Nurse Call Equipment under file
number E206037.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-DM-# Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-DM-# MULTI-SECTIONAL DOME LAMP
The multi-sectional dome lamp, DM-1 thru DM-4, shall be surface, wall or ceiling mounted available for
use as 1 section (single) to 4 section dome lamp.
The HM-DM-# shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
file number E206037.
The lamps shall be Bayonet type, long life incandescent lamps rated at 100 mA at 28 volts DC each,
replaceable from the front. Available colors; white, red, green or amber.
The HM-DM# shall use prewired connectors to facilitate easy installation and mount using only the four
6-32 x 1" nylon screws provided.
The faceplate shall be of high impact molded ABS with flame retardant properties finished in off-white.
The dome lens shall be of high impact translucent acrylic with flame retardant properties finished in
white translucent.
The Faceplate & Dome Lens shall be 4 ½" (11.43cm) high x 4 9/16" (11.59cm) wide x 3" (7.62cm)
deep. W42 Backbox: 4-11/16” (11.91cm) wide square electrical backbox with two gang adapter for
total depth of 2-7/8” (7.30cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
03/04 HM-DM-# Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
ONE BUTTON SWITCH PANEL
HM-1B, HM-1B/K2
Illuminated Pushbutton
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted one button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
One combination pushbutton and lamp indicator.
Standard lens color is white, others available
separately include: red, amber, green, blue,
yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are front replaceable with rated average
life of 6000 hours.
SWITCH
Switch is normally-open, single-pole / single
throw. HM-1B is momentary operation, HM-1B/
K2 is latching (push-on / push-off). All switches
are rated 1A /125 VAC.
Rear
Side
INSTALLATION
Plugs into prewired connectors.
HM-1B requires one HM-4P
HM-1B/K2 requires one HM-4P
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-1B/K2 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM1B Issue C
Printed in U.S.A.
Architects’ and Engineers’ Specifications
Model HM-1B / 1B/K2 One Button Switch Panel
The wall recessed or surface mounted HM-1B / HM-1B/K2 One Button Switch Panel shall be available
for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push button shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-1B/K2 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
The HM-1B shall contain one momentary normally-open SPST switch; the HM-1B/K2 shall contain one
latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM1B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TWO BUTTON SWITCH PANEL
HM-2B, HM-2B/K2
Illuminated Pushbuttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted two button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Two combination pushbutton and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
SWITCH
Switches are normally-open, single-pole / single
throw. HM-2B is momentary operation, HM-2B/
K2 is latching (push-on / push-off). All switches
are rated 1A /125 VAC.
Top: HM-2B
Bottom: HM-2B/K2
INSTALLATION
Plugs into prewired connectors.
HM-2B requires one HM-6P
HM-2B/K2 requires two HM-4P
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-2B/K2 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM2B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-2B / HM-2B/K2 TWO BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-2B / HM-2B/K2 Two Button Switch Panel shall be available
for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with two combination pushbutton and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-2B/K2 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
The HM-2B shall contain two momentary normally-open SPST switches; the HM-2B/K2 shall contain
two latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM2B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
THREE BUTTON SWITCH PANEL
HM-3B, HM-3B/K2
Illuminated Pushbuttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted three button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Three combination pushbutton and lamp
indicator. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
SWITCH
Switches are normally-open, single-pole / single
throw. HM-3B is momentary operation, HM-3B/
K2 is latching (push-on / push-off). All switches
are rated 1A /125 VAC.
Top: 3B
Bottom: 3B/K2
Top: 3B
Bottom: 3B/K2
INSTALLATION
Plugs into prewired connectors.
HM-3B requires one HM-8P
HM-3B/K2 requires three HM-4P
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-3B/K2 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM3B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-3B - 3B/K2 THREE BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-3B / HM-3B/K2 Three Button Switch Panel shall be available
for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with three combination pushbutton and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-3B/K2 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The HM-3B shall contain three momentary normally-open SPST switches; the HM-3B/K2 shall contain
three latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM3B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FOUR BUTTON SWITCH PANEL
HM-4B, HM-4B/K2
H
M
4
B
Illuminated Push-buttons
Momentary or Latching Switches Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connector
HM-4B, 4B/K2 FRONT
DESCRIPTION
Wall recessed or surface mounted four button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Four combination push-button and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, black.
Lamps are front replaceable with rated average
life of 6000 hours.
Lamps are rated at 24 VDC at 40 mA.
SWITCHES
Switches are normally-open single-pole/single
throw. HM-4B is momentary operation, HM-4B/
K2 is latching (push-on / push-off). Switch
contacts rated 1A - 125 VAC.
H
M
4
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-4B requires one HM-10P connector.
HM-4B/K2 requires four HM-4P connectors.
Mount using only the four 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white supplied with
nylon mounting screws; W42 Backbox: metal
backbox supplied by others.
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high; W42 Backbox: 4-11/16”
(11.91cm) square electrical backbox with two
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
Important Note: Backbox to be installed
rotated 90 degrees for proper panel
orientation.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM4B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-4B - HM4B/K2 FOUR BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-4B / HM4B/K2 Four Button Switch Panel shall be available
for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with four combination push-button and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-4B shall contain four momentary normally-open SPST switches; the HM-4B/K2 shall contain
four latching normally-open SPST switches (push-on / push-off).
Faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Four 6-32 x 1" nylon screws shall be provided for attaching switch plate to backbox.
Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall
be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm)
square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied by others.
Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM4B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
SIX BUTTON SWITCH PANEL
HM-2-3B, HM-2-3B/K2
2
3
B
/
K
2
Illuminated Pushbuttons
Variety of Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
2
3
B
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted six button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Six combination pushbuttons and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black. Custom laminated
labels are available for lenses. Lamps are front
replaceable with rated average life of 6000 hours.
Lamps are rated 24 VDC at 40 mA.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-2-3B is momentary operation, HM-23B/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
INSTALLATION
Plugs into prewired connectors.
HM-2-3B requires two HM-8P
HM-2-3B/K2 requires six HM-4P
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high; W42 Backbox: 4-11/16”
(11.91cm) square electrical backbox with two
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
IMPORTANT NOTE: Backbox to be installed
rotated 90 degrees for proper panel
orientation.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-2-3B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-2-3B - HM-2-3B/K2 SIX BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-2-3B Six Button Switch Panel shall be available for use as a
system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with six combination pushbuttons and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-2-3B shall contain six momentary normally-open SPST switches; the HM-2-3B/K2 shall contain
six latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall
be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm)
square electrical backbox with one gang adapter for total depth of 3-5/16" (8.41cm), supplied by others.
Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-2-3B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
EIGHT BUTTON SWITCH PANEL
HM-2-4B, HM-2-4B/K2
2
4
B
/
K
2
Illuminated Pushbuttons
Variety of Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
2
4
B
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted eight button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Eight combination pushbuttons and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black. Custom laminated
labels are available for lenses. Lamps are front
replaceable with rated average life of 6000 hours.
Lamps are rated 24 VDC at 40 mA.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-2-4B is momentary operation, HM-24B/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
INSTALLATION
Plugs into prewired connectors.
HM-2-4B requires two HM-10P
HM-2-4B/K2 requires eight HM-4P
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high; W42 Backbox: 4-11/16”
(11.91cm) square electrical backbox with two
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
IMPORTANT NOTE: Backbox to be installed
rotated 90 degrees for proper panel
orientation.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-2-4B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-2-4B - HM-2-4B/K2 EIGHT BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-2-4B Eight Button Switch Panel shall be available for use as
a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with eight combination pushbuttons and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-2-4B shall contain eight momentary normally-open SPST switches; the HM-2-4B/K2 shall
contain eight latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box for surface or wall flush mounting. The dimensions shall
be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16” (11.91cm)
square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied by others.
Important Note: The backbox shall be installed rotated 90 degrees for proper panel orientation.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM2-4B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TEN BUTTON SWITCH PANEL
HM-2-5B, HM-2-5B/K2
H
M
2
5
B
Illuminated Push-buttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted ten button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Ten combination push-button and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
H
M
2
5
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-2-5B requires two HM-12P
HM-2B/K2 requires ten HM-4P
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 6-3/8” (16.19cm) wide x 4-1/2”
(11.43cm) high; Backbox: 5-3/4" (14.6cm) wide
by 4" (10.16) high electrical backbox with three
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-2-5B is momentary operation, HM-25B/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM2-5B Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-2-5B - HM2-5B/K2 TEN BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-2-5B / HM-2-5B/K2 Ten Button Switch Panel shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with ten combination push-button and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-2-5B shall contain ten momentary normally-open SPST switches; the HM-2-5B/K2 shall contain
ten latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a three gang box with a three gang adapter for surface or wall flush
mounting. The dimensions shall be: Faceplate - 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high;
Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm) high electrical backbox with three gang adapter for
total depth of 3-5/16” (8.41cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM2-5B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TWENTY BUTTON SWITCH PANEL
HM-A20PB, HM-A20PB/K2
H
M
A
2
0
P
B
Illuminated Push-buttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connectors
HM-A20PB, HM-A20PB/K2
DESCRIPTION
Wall recessed or surface mounted twenty button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Twenty combination push-button and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
H
M
A
2
0
P
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-A20PB requires four HM-12P.
HM-A20PB/K2 requires twenty HM-4P.
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high;
W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm)
high x 3-1/2" deep.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-A20PB is momentary operation, HMA20PB/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A20PB Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A20PB, HM-A20PB/K2 TWENTY BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-A20PB / HM-A20PB/K2 Twenty Button Switch Panel shall
be available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with twenty combination push-button and lamp indicators. Lens
colors shall be available (separately). Lamps shall be front replaceable with rated average life of 6000
hours.
The HM-A20PB shall contain twenty momentary normally-open SPST switches; the HM-A20PB/K2 shall
contain twenty latching normally-open SPST switches.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions
shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide
x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A20PB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICA
TIONS
SPECIFICATIONS
THIRTY BUTTON SWITCH PANEL
HM-A30PB, HM-A30PB/K2
3
0
P
B
/
K
2
Illuminated Push-button
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
3
0
P
B
Connections via Prewired Connectors
Front
Rear
DESCRIPTION
INSTALLATION
Wall recessed or surface mounted thirty button switch
panel with facilities for feature activation and/or system
status display. Momentary or latching switches are
available.
Plugs into prewired connectors.
HM-A30PB requires six HM-12P
HM-A30PB/K2 requires thirty HM-4P
Mounts onto backbox with four 6-32 x 1" nylon screws
provided.
CONTROLS AND INDICATORS
Thirty combination push-button and lamp indicators.
Standard lens color is white, others available separately
include: red, amber, green, blue, yellow, clear, and black.
Custom laminated labels are available for lenses. Lamps are
rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average life of 6000
hours.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with baked epoxy
finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11” (27.94cm) high;
W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm) high x 3-1/2"
deep.
SWITCHES
Switches are normally-open, single-pole / single throw.
HM-A30PB is momentary operation, HM-A30PB/K2 is
latching (push-on / push-off). All switches are rated 1A /
125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A30PB Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
THIRTY BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-A30PB / HM-A30PB/K2 Thirty Button Switch Panel shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature activation
and/or overall system status.
The button panel shall be provided with thirty combination push-button and lamp indicators. Lens colors shall be
available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-A30PB shall contain thirty momentary normally-open SPST switches; the HM-A30PB/K2 shall contain
thirty latching normally-open SPST switches.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the button panel
shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions shall be:
faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide x 10" (25.40cm)
high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage.
© 2004Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A30PB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FORTY BUTTON SWITCH PANEL
HM-A40PB, HM-A40PB/K2
H
M
A
4
0
P
B
Illuminated Push-buttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connectors
HM-A40PB, HM-A40PB/K2
DESCRIPTION
Wall recessed or surface mounted forty button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Forty combination push-button and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
H
M
A
4
0
P
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-A40PB requires eight HM-12P
HM-A40PB/K2 requires forty HM-4P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high;
W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm)
high x 3-1/2" deep.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-A40PB is momentary operation, HMA40PB/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
12/02 HM-A40PB Issue A
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
HM-40PB, HM-40PB/K2 FORTY BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-A40PB / HM-A40PB/K2 Forty Button Switch Panel shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with forty combination push-button and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-A40PB shall contain forty momentary normally-open SPST switches; the HM-A40PB/K2 shall
contain forty latching normally-open SPST switches.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions
shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide
x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A40PB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FIFTY BUTTON SWITCH PANEL
HM-A50PB, HM-A50PB/K2
H
M
A
5
0
P
B
Illuminated Push-buttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connectors
HM-A50PB, HM-A50PB/K2
DESCRIPTION
Wall recessed or surface mounted fifty button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Fifty combination push-button and lamp
indicators. Standard lens color is white, others
available separately include: red, amber, green,
blue, yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
H
M
A
5
0
P
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-A50PB requires ten HM-12P
HM-A50PB/K2 requires fifty HM-4P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm)
high x 3-1/2" deep.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-A50PB is momentary operation, HMA50PB/K2 is latching (push-on / push-off). All
switches are rated 1A /125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A50PB Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A50PB, HM-A50PB/K2 FIFTY BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-A50PB / HM-A50PB/K2 Fifty Button Switch Panel shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with fifty combination push-button and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-A50PB shall contain fifty momentary normally-open SPST switches; the HM-A50PB/K2 shall
contain fifty latching normally-open SPST switches.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions
shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide
x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage.
© 2004Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A50PB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
SIXTY BUTTON SWITCH PANEL
HM-A60PB, HM-A60PB/K2
H
M
A
6
0
P
B
Illuminated Push-buttons
Two Switch Configurations Available
Variety of Lens Colors Available
Displays System Status/Feature Activation
Connections via Prewired Connectors
HM-A60PB, HM-A60PB/K2
DESCRIPTION
Wall recessed or surface mounted sixty button
switch panel with facilities for feature activation
and/or system status display. Momentary or
latching switches are available.
CONTROLS AND INDICATORS
Sixty combination push-button and lamp indicators. Standard lens color is white, others available separately include: red, amber, green, blue,
yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
H
M
A
6
0
P
B
/
K
2
INSTALLATION
Plugs into prewired connectors.
HM-A60PB requires twenty HM-8P
HM-A60PB/K2 requires sixty HM-4P.
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high;
W2 Backbox: 7-1/2” (19.05cm) x 10" (25.40cm)
high x 3-1/2" deep.
SWITCHES
Switches are normally-open, single-pole / single
throw. HM-A60PB is momentary operation,
HM-A60PB/K2 is latching (push-on / push-off).
All switches are rated 1A /125 VAC.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A60PB Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
HM-60PB , HM-60PB/K2 SIXTY BUTTON SWITCH PANEL
The wall recessed or surface mounted HM-A60PB / HM-A60PB/K2 Sixty Button Switch Panel shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push buttons shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicators shall illuminate to show feature
activation and/or overall system status.
The button panel shall be provided with sixty combination push-button and lamp indicators. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-A60PB shall contain sixty momentary normally-open SPST switches; the HM-A60PB/K2 shall
contain sixty latching normally-open SPST switches.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Button panel shall install into a W2 steel electrical backbox for wall flush mounting. The dimensions
shall be: faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2” (19.05cm) wide
x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A60PB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
ONE POSITION DOME LIGHT
HM-D1
MAXIMUM VISIBILITY
7 LENS COLORS AVAILABLE
PLUG IN LENSES
FLEXIBLE INSTALLATION
Front
Rear
Side
DESCRIPTION
HOUSING AND FINISH
Surface, wall or ceiling mounted dome lamp.
Consists of a faceplate with combination lamp
socket and lens holder. Lens colors available
(white, green, red, blue, amber, yellow or clear).
Faceplate: Punched aluminum faceplate with
baked epoxy finish, finished in off-white and
supplied with nylon mounting screws.
CONTROLS AND INDICATORS
Low-power high-luminous lamp, front replaceable
with rated average life of 6000 hours.
INDICATOR CONFIGURATIONS
HM-D1 provides indicators only.
LAMP
28V at 40ma. 28ESB T-2 slide base.
INSTALLATION
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-D1 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Prewired connectors.
Mount using only the two 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-D1 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-D1 ONE POSITION DOME LIGHT
The wall recessed or surface mounted Model HM-D1 One Lamp Dome Panel shall provide visual
indication for system status via indicators.
The HM-D1 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable
with an average life of 6000 hours. Lens colors shall be available (separately).
The EX-D1 shall be feature indicator only.
The faceplate shall be 1/16, punched aluminum faceplate with baked epoxy, finished in off-white and
supplied with nylon mounting screws.
The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished.
The unit shall be prewired for ease of installation.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-D1 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TWO POSITION DOME LIGHT
HM-D2
MAXIMUM VISIBILITY
7 LENS COLORS AVAILABLE
PLUG IN LENSES
FLEXIBLE INSTALLATION
Front
Rear
Side
DESCRIPTION
HOUSING AND FINISH
Surface, wall or ceiling mounted dome lamp.
Consists of a faceplate with combination lamp
socket and lens holder. Lens colors available
(white, green, red, blue, amber, yellow or clear).
Faceplate: Punched aluminum faceplate with
baked epoxy finish, finished in off-white and
supplied with nylon mounting screws.
CONTROLS AND INDICATORS
Low-power high-luminous lamp, front replaceable
with rated average life of 6000 hours.
INDICATOR CONFIGURATIONS
HM-D2 provides indicators only.
LAMPS
28V at 40ma. 28ESB T-2 slide base.
INSTALLATION
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-D2 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Prewired connectors.
Mount using only the two 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
02/03 HM-D2 Issue A
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-D2 TWO POSITION DOME LIGHT
The wall recessed or surface mounted Model HM-D2 Two Lamp Dome Panel shall provide visual
indication for system status via indicators.
The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable
with an average life of 6000 hours. Lens colors shall be available (separately).
The HM-D2 shall be UL and CUL listed Hopital Signaling Equipment / Nurse Call Equipment under Fille
E157381.
The HM-D2 shall be feature indicator only.
The faceplate shall be 1/16, punched aluminum faceplate with baked epoxy, finished in off-white and
supplied with nylon mounting screws.
The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished.
The unit shall be prewired for ease of installation.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox - 411/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2002 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-D2 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
THREE POSITION DOME LIGHT
HM-D3
MAXIMUM VISIBILITY
7 LENS COLORS AVAILABLE
PLUG IN LENSES
FLEXIBLE INSTALLATION
Front
Rear
Side
DESCRIPTION
HOUSING AND FINISH
Surface, wall or ceiling mounted dome lamp.
Consists of a faceplate with combination lamp
socket and lens holder. Lens colors available
(white, green, red, blue, amber, yellow or clear).
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
CONTROLS AND INDICATORS
Low-power high-luminous lamps, front
replaceable with rated average life of 6000 hours.
INDICATOR CONFIGURATIONS
HM-D3 provides indicators only.
LAMPS
28V at 40ma. 28ESB T-2 slide base.
INSTALLATION
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-D3 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
Prewired connectors.
Mount using only the two 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-D3 Issue C
Printed in U.S.A.
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
MODEL HM-D3 THREE POSITION DOME LIGHT
The wall recessed or surface mounted Model HM-D3 Three Lamp Dome Panel shall provide visual
indication for system status via indicators.
The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable
with an average life of 6000 hours. Lens colors shall be available (separately).
The HM-D3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The HM-D3 shall be feature indicator only.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
The dome light panel shall mount onto a backbox or surface housing with two nylon screws furnished.
The unit shall be prewired for ease of installation.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox - 411/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-D3 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FOUR POSITION DOME LIGHT
HM-D4
MAXIMUM VISIBILITY
7 LENS COLORS AVAILABLE
PLUG IN LENSES
FLEXIBLE INSTALLATION
Front
Rear
DESCRIPTION
HOUSING AND FINISH
Surface, wall or ceiling mounted dome lamp.
Consists of a faceplate with combination lamp
socket and lens holder. Lens colors available
(white, green, red, blue, amber, yellow or clear).
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white supplied with
nylon mounting screws; W42 Backbox: metal
backbox supplied by others.
CONTROLS AND INDICATORS
Low-power high-luminous lamps, front
replaceable with rated average life of 6000 hours.
INDICATOR CONFIGURATIONS
HM-D4 provides indicators only.
LAMPS
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high; W42 Backbox: 4-11/16”
(11.91cm) square electrical backbox with two
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
28V at 40ma. 28ESB T-2 slide base.
LISTINGS
INSTALLATION
The HM-D4 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Prewired connectors.
Mount using only the four 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
11/07 HM-D4 Issue C
Printed in U.S.A.
ARCHITECTS' AND ENGINEERS' SPECIFICATIONS
MODEL HM-D4 FOUR POSITION DOME LIGHT
The wall recessed or surface mounted Model HM-D4 Four Lamp Dome Panel shall provide visual
indication for system status via indicators.
The HM-D4 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The panel shall be provided with low-power high-luminous indicators, lamps shall be front replaceable
with an average life of 6000 hours. Lens colors shall be available (separately).
The HM-D4 shall be feature indicator only.
Faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white.
The dome light panel shall mount onto a backbox or surface housing with four nylon screws furnished.
The unit shall be prewired for ease of installation.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Dome Light panel shall install into a two gang box for surface or wall flush mounting. The dimensions
shall be: Faceplate - 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 backbox - 4-11/16”
(11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16" (8.41cm), supplied
by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-D4 Issue C
Design and Specifications subject to change without notice.
HM-A10
Side
Rear
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
TEN LAMP ANNUNCIATOR PANEL
Front
TECHNICAL
SPECIFICATIONS
DESCRIPTION
Wall recessed or surface mounted ten lamp call
annunciator panel providing visual system status
indication via ten lamp positions.
INDICATORS
Ten low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-A10 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
INSTALLATION
Plugs into prewired connectors.
HM-A10 requires one HM-11P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 6-3/8” (16.19cm) wide x 4-1/2”
(11.43cm) high.
Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm)
high electrical backbox with three gang adapter
for total depth of 3-5/16” (8.41cm), supplied by
others.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A10 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A10 TEN POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A10 Ten Position Annunciator Panel shall provide visual
status indication via 10 lamp positions.
The panel shall provide ten low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The HM-A10 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a three gang box with a three gang adapter for surface or wall flush
mounting. The dimensions shall be: Faceplate - 6-3/8” (16.19cm) wide x 4-1/2” (11.43cm) high;
Backbox: 5-3/4" (14.6cm) wide by 4" (10.16cm) high electrical backbox with three gang adapter for
total depth of 3-5/16” (8.41cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A10 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TWENTY LAMP ANNUNCIATOR PANEL
HM-A20
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted twenty lamp
call annunciator panel providing visual system
status indication via twenty lamp positions.
INDICATORS
Twenty low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-A20 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
Rear
INSTALLATION
Plugs into prewired connectors.
HM-A20 requires two HM-11P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: Punched aluminum faceplate with
baked epoxy finish, finished in off-white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) wide x 10"
(25.4cm) high x 3 1/2" (8.89 cm) deep, available
separately from Heritage.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A20 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A20 TWENTY POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A20 Twenty Position Annunciator Panel shall provide visual
status indication via 20 lamp positions.
The panel shall provide twenty low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The HM-A20 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
annunciator panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting.
The dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2”
(19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available
from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A20 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
THIRTY LAMP ANNUNCIATOR PANEL
HM-A30
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted thirty lamp
call annunciator panel providing visual system
status indication via thirty lamp positions.
INDICATORS
Thirty low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-A30 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
Rear
INSTALLATION
Plugs into prewired connectors.
HM-A30 requires three HM-11P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) wide x 10"
(25.4cm) high x 3 1/2" (8.89 cm) deep, available
separately from Heritage.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A30 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A30 THIRTY POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A30 Thirty Position Annunciator Panel shall provide visual
status indication via 30 lamp positions.
The panel shall provide thirty low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The HM-A30 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
annunciator panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The
dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2”
(19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available
from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A30 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FORTY LAMP ANNUNCIATOR PANEL
HM-A40
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted forty lamp call
annunciator panel providing visual system status
indication via forty lamp positions.
INDICATORS
Forty low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-A40 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Rear
INSTALLATION
Plugs into prewired connectors.
HM-A40 requires four HM-11P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) wide x 10"
(25.4cm) high x 3 1/2" (8.89 cm) deep, available
separately from Heritage.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A40 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A40 FORTY POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A40 Forty Position Annunciator Panel shall provide visual
status indication via 40 lamp positions.
The panel shall provide forty low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The HM-A40 is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
annunciator panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The
dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2”
(19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available
from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A40 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FIFTY LAMP ANNUNCIATOR PANEL
HM-A50
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted fifty lamp call
annunciator panel providing visual system status
indication via fifty lamp positions.
INDICATORS
Fifty low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-50 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Rear
INSTALLATION
Plugs into prewired connectors.
HM-A50 requires five HM-11P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) wide x 10"
(25.4cm) high x 3 1/2" (8.89 cm) deep, available
separately from Heritage.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A50 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A50 FIFTY POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A50 Fifty Position Annunciator Panel shall provide visual
status indication via 50 lamp positions.
The panel shall provide fifty low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The HM-50 shall be UL and CUL llisted Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
annunciator panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The
dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2”
(19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available
from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A50 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
SIXTY LAMP ANNUNCIATOR PANEL
HM-A60
Displays System Status
Low-Power High-Visibility Lamps
Variety of Lens Colors Available
Connections via Prewired Connectors
Front
DESCRIPTION
Wall recessed or surface mounted sixty lamp call
annunciator panel providing visual system status
indication via sixty lamp positions.
INDICATORS
Sixty low-power high visibility lamps. Standard
lens color is white, others available separately
include: red, amber, green, blue, yellow and
clear.
Custom laminated labels are available for lenses.
Lamps are rated 24 VDC at 40 mA.
Lamps are front replaceable with rated average
life of 6000 hours.
LISTINGS
The HM-60 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Rear
INSTALLATION
Plugs into prewired connectors.
HM-A60 requires five HM-13P
Mounts onto backbox with four 6-32 x 1" nylon
screws provided.
HOUSING AND FINISH
Faceplate: punched aluminum faceplate with
baked epoxy finish, finished in off white.
DIMENSIONS
Faceplate: 8-1/2” (21.59cm) wide x 11”
(27.94cm) high.
W2 Backbox: 7-1/2” (19.05cm) wide x 10"
(25.4cm) high x 3 1/2" (8.89 cm) deep, available
separately from Heritage.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-A60 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-A60 SIXTY POSITION ANNUNCIATOR PANEL
The wall recessed or surface mounted HM-A60 Sixty Position Annunciator Panel shall provide visual
status indication via 60 lamp positions.
The HM-60 shall be UL and CUL llisted Hospital Signaling Equipment. Nurse Call Equipment under File
E157381.
The panel shall provide sixty low-power high-visibility indicator lamps. Lamps shall be front panel
replaceable with an average rated life of 6000 hours. Standard lens color shall be white. Others lens
colors available separately shall be red, amber, green, blue, yellow, and clear.
The faceplate shall be metal, finished in off-white and flame retardant. For ease of installation, the
annunciator panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with four 6-32 x 1" nylon screws provided.
Annunciator panel shall install into a W2 steel electrical backbox for wall flush mounting. The
dimensions shall be: Faceplate - 8-1/2” (21.59cm) wide x 11” (27.94cm) high; W2 backbox - 7-1/2”
(19.05cm) wide x 10" (25.40cm) high x 3 1/2" (8.89cm) deep, for total depth of 3-3/4" (9.53cm), available
from Heritage.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-A60 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
W2 BACK BOX
HM-W2BB
Steel Back Box for A20 - A60 Annunciators
Steel Back Box for A20PB- A60PB Switch
Panels
DESCRIPTION
Mill finished steel back-box for flush mounting
Heritage MedCall A20 - A60 Annuciator Lamp
Panels, and A20PB - A60PB Push-button Panels.
CONNECTIONS
Top, bottom and sides of the back-box are
predrilled for connection to 1" conduit fittings.
ENCLOSURE
Rugged sheet metal back box for secure flush
mounting of Heritage annunciator / lamp panels.
INSTALLATION
Mount securely to a wall stud by drilling appropriate holes for suitable fasteners. Mount horizontally or vertically as determined by orientation of
annunciator plate. Make sure when mounting that
consideration is given to the thickness of the wall
material being used for placement of the back
box. Connect conduit to back box per code.
Make sure all burrs and sharp edges are removed. Use provided speed-nut fasteners for
mounting face panel.
HOUSING AND FINISH
Mill finished steel back box.
DIMENSIONS
7 1/2" (19.1cm) wide x 10 1/8" (25.7cm) high x 3"
(7.6cm) deep.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-W2BB Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-W2BB BACK BOX
The flush mount back box will be the method for flush mounting Heritage MedCall A20 - A60 and A20PB
- A60PB annunciator / push-button panels.
The back box will be mounted as shown on the plans and will be oriented as dictated by the desired
orientation of the annunciator / push-button panels.
Openings in the back box which are not used for attachment of conduit will be plugged by suitable
means, per code.
All burrs and sharp edges will be removed prior to pulling wire into the back box.
Maximum dimensions on the card cage shall be: 7 1/2" (19.1cm) wide x 10 1/8" (25.7cm) high x 3"
(7.6cm) deep.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-W2BB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
DESKTOP ANNUNCIATOR CONSOLE
HM-DAC
All sides laminated
3/4' Particle Board
Pre-Drilled Hole for Cable
Pre-Drilled Hole for Tone Unit
DESCRIPTION
HM-DAC Desktop Annunciator Console provides a
desktop mounting option for A-20(PB) through
A-60(PB).
DIMENSIONS
8.75" W X 6" H X 10.5" L
Contact Heritage for other special order sizes.
HOUSING
3/4" particle board laminated on all sides in off
white color.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
05/06 HM-DAC Issue C
Printed in U.S.A.
TECHNICAL
SPECIFICATIONS
PRE-WIRED CONNECTORS
HM-4P,HM-6P,HM-8P,HM-10P,
HM-11P,HM-12P,HM-13P
Single In-line Polarized Connector
Color Coded Tined Leads
22 Gauge Wire 0.10" Center
Nylon Connector Housing
HM-4P HM-6P HM-8P
HM-10P HM-11P HM-12P HM-13P
DESCRIPTION
INSULATION
Connectors used in the Heritage Visual Nurse Call
Systems (VNS) and CliniComm Systems for push
button panels and annunciator panels.
Color coded semi-rigid PVC insulation.
Maximum thickness .41mm.
CONNECTOR
GAUGE AND TYPE
Single in-line polarized nylon connector.
22 gauge stranded copper wire with tinned leads.
Rated temperature: 80º C
Rated voltage: 300 volts
UL listed style 1007 wire.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 Connectors Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-4P, HM-6P, HM-8P, HM-10P, HM-11P, HM-12P, HM-13P
The HM-##P connectors shall be used in the Heritage Medcall Visual Nurse Call Systems (VNS) and the CliniComm
Systems for push button panels and annunciator panels to aid in installation.
The wire shall be of 22 gauge stranded copper wire with tinned leads with a rated temperature of 80º C and a voltage
rating of 300 volts and UL listed 1007.
Insulation shall be color coded semi-rigid PVC insulation with a maximum thickness of .41mm.
Connector shall be nylon single in-line polarized connector.
© 2004Heritage MedCall, Inc.
Printed in U.S.A.
01/04 Connectors Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
EMERGENCY CALL SWITCH
HM-1B/K2 (Emergency)
Illuminated Pushbutton
Silk-Screened Labeled Emergency
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted one button
switch panel with silk-screened Emergency
Label. Latching switch.
CONTROLS AND INDICATORS
One combination pushbutton and lamp indicator.
Standard lens color is red, others available
separately include white, amber, green, blue,
yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are front replaceable with rated average
life of 6000 hours.
SWITCH
Switch is normally-open, single-pole / single
throw. HM-1B/K2 (EMERGENCY) is latching
(push-on / push-off). All switches are rated 1A /
125 VAC.
Rear
Side
INSTALLATION
Plugs into prewired connectors.
HM-ESC requires one HM-4P
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-1B/K2 (EMERGENCY) is UL and CUL
listed Hospital Signaling Equipment / Nurse Call
Equipment under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
04/03 HM-1B/K2 (EMERGENCY) Issue A
Printed in U.S.A.
Architects’ and Engineers’ Specifications
Model HM-1B/K2 (EMERGENCY) Emergency Call Switch
The wall recessed or surface mounted HM-1B/K2 (EMERGENCY) Emergency Call Switch shall be
available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push button shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature
activation and/or overall system status.
The HM-1B/K2 (EMERGENCY) shall be silk-screened labeled with the words "EMERGENCY CALL" in
bold red lettering.
The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-1B/K2 (EMERGENCY) shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call
Equipment under File E157381.
The HM-1B/K2 (EMERGENCY) shall contain one latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2002 Heritage MedCall, Inc.
Printed in U.S.A.
04/03 HM-1B/K2 (EMERGENCY) Issue A
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
CODE BLUE CALL SWITCH
HM-1B/K2 (Code Blue)
Illuminated Pushbutton
Silk-Screened Labeled Code Blue
Connections via Prewired Connector
Front
DESCRIPTION
Wall recessed or surface mounted one button
switch panel with silk-screened Code Blue Label.
Latching switch.
CONTROLS AND INDICATORS
One combination pushbutton and lamp indicator.
Standard lens color is blue others available
separately include white, amber, green, red,
yellow, clear, and black.
Custom laminated labels are available for lenses.
Lamps are front replaceable with rated average
life of 6000 hours.
SWITCH
Switch is normally-open, single-pole / single
throw. HM-1B/K2 (CODE BLUE) is latching
(push-on / push-off). All switches are rated 1A /
125 VAC.
Rear
Side
INSTALLATION
Plugs into prewired connectors.
HM-1B/K2 (CODE BLUE) requires one HM-4P
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
LISTINGS
The HM-1B/K2 (CODE BLUE) is UL and CUL
listed Hospital Signaling Equipment / Nurse Call
Equipment under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-1B/K2 (CODE BLUE) Issue C
Printed in U.S.A.
Architects’ and Engineers’ Specifications
Model HM-1B/K2 (CODE BLUE), CODE BLUE SWITCH
The wall recessed or surface mounted HM-1B/K2 (CODE BLUE) Code Blue Emergency Switch shall
be available for use as a system feature input device as well as a status indicator.
Feature Input Device - As a system feature input device, the push button shall be used for feature
activation.
Status Indication - To provide status indication, the lamp indicator shall illuminate to show feature
activation and/or overall system status.
The HM-1B/K2 (CODE BLUE) shall be silk-screened labeled with the words "CODE BLUE" in bold blue
lettering.
The button panel shall be provided with one combination pushbutton and lamp indicator. Lens colors
shall be available (separately). Lamps shall be front replaceable with rated average life of 6000 hours.
The HM-1B/K2 (CODE BLUE) shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call
Equipment under File E157381.
The HM-1B/K2 (CODE BLUE) shall contain one latching normally-open SPST switches.
The faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. For ease of
installation, the button panel shall plug into pre-wired connectors.
Faceplate shall mount to backbox with two 6-32 x 1" nylon screws provided.
Button panel shall install into a two gang box with single gang adapter for surface or wall flush mounting.
The dimensions shall be: Faceplate - 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 backbox 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8" (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-1B/K2 (CODE BLUE) Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICA
TIONS
SPECIFICATIONS
24 VOLT 2.5A POWER SUPPLY
HM-24V-2.5A
Low Profile
Lightweight Single Output
Global Safety Agency Compliance
Low Conducted EMI
DESCRIPTION
Single output regulated DC power supply rated
for 24 volts at 2.5 amps.
OUTPUT PROTECTION
Current limiting and overvoltage crowbar
protected, auto restart.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 0ºC to 40ºC (32ºC to
104ºF)
Storage Temperature: -40ºC to 70ºC (-40ºF to
158ºF)
POWER REQUIREMENTS
Input voltage range 90-264VAC, 47- 63 hz
maximum 27A.
HOOKUP
Prewired connector.
OUTPUT
Voltage: nominal 24 volts DC ± 720mV.
Current: Up to 2.5 Amps.
Ripple and Noise: Maximum 240mV.
LINE CORD
Heavy duty six foot (1.83m) terminated with
molded three-prong plug.
HOUSING
ABS plastic black casing.
DIMENSIONS
Maximum dimensions are 5.14" L (130.5mm ) x
2.72" W (69 mm) x 1.57" H (40 mm).
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
Printed in U.S.A.
01/04 HM-24V-2.5A Issue C
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-24V-2.5A POWER SUPPLY 24 VOLT 2.5 AMP
The HM-24V-2.5A power supply shall provide a regulated DC single output rated for 24 volts at 2.5 amps
maximum. The power supply shall contain overloading, short circuit, and overvoltage protection.
The power supply shall be designed for a long life of continuous duty operation. Operating temperature
shall be 0ºC to 40ºC (32ºC to 104ºF). Storage temperature shall be -40ºC to 70ºC (-40ºF to 158ºF).
The input power requirements shall be 90 to 264 VAC at 47 to 63 hz maximum 27 amps.
The output voltage shall be nominal 24 volts DC ±720mV up to 2.5 amps. Ripple and noise shall be
maximum 240 mV. The output shall be floating with respect to ground.
A heavy duty six-foot (1.83m) line cord terminated with molded three-prong plug shall be provided for
input connections. The output connection shall be prewired molded connector.
The power supply shall be housed in ABS plastic. The housing maximum dimensions shall be 5.14" L
(130.5mm ) x 2.72" W (69 mm) x 1.57" H (40 mm).
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-24V-2.5A Issue
Design and Specifications subject to change without notice.
C
TECHNICAL
SPECIFICA
TIONS
SPECIFICATIONS
5 VOLT 10A POWER SUPPLY
HM-5V-10A
Low Profile
Lightweight Single Output
Global Safety Agency Compliance
Low Conducted EMI
DESCRIPTION
Single output regulated DC power supply rated
for 5 volts at 10 amps.
OUTPUT PROTECTION
Current limiting and overvoltage crowbar
protected, auto restart.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature: 0ºC to 40ºC (32ºC to
104ºF)
Storage Temperature: -40ºC to 70ºC (-40ºF to
158ºF)
HOOKUP
Prewired connector.
POWER REQUIREMENTS
Input voltage range 90-264VAC, 47- 63 hz
maximum 27A.
OUTPUT
Voltage: nominal 5 volts DC ± 250mV.
Current: Up to 10 Amps.
Ripple and Noise: Maximum 50mV peak to peak
Power: 50 Watts Maximum.
LINE CORD
Heavy duty six foot (1.83m) terminated with
molded three-prong plug.
HOUSING
ABS plastic black casing.
DIMENSIONS
Maximum dimensions are 6.06" L (154mm) x
3.35" W (85mm) x 2.09" H (53mm).
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-5V-10A Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-5V-10A POWER SUPPLY 5 VOLT 10 AMP
The HM-5V-10A power supply shall provide a regulated DC single output rated for 5 volts at 10 amps
maximum. The power supply shall contain overloading, short circuit, and overvoltage protection.
The power supply shall be designed for a long life of continuous duty operation. Operating temperature
shall be 0ºC to 40ºC (32ºC to 104ºF). Storage temperature shall be -40ºC to 70ºC (-40ºF to 158ºF).
The input power requirements shall be 90 to 264 VAC at 47 to 63 hz maximum 27 amps.
The output voltage shall be nominal 5 volts DC ±250mV up to 10 amps. Ripple and noise shall be
maximum 50 mV. The output shall be floating with respect to ground.
A heavy duty six-foot (1.83m) line cord terminated with molded three-prong plug shall be provided for
input connections. The output connection shall be prewired molded connector.
The power supply shall be housed in ABS plastic. The housing maximum dimensions shall be 6.06" L
(154mm) x 3.35" W (85mm) x 2.09" H (53mm).
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-5V-10A Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
DUTY STATION
HM-DUTY
Visual/Audio Patient Call Indication
Interrupted Tone Signal for Emergency Call
Differentiation of Type of Call Placed
UL Listed
Front
Rear
Side
DESCRIPTION
Wall recessed or surface mounted duty station
provides visual and audible indication of normal
and emergency calls placed.
INSTALLATION
Color-coded prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided
CONTROLS AND INDICATORS
One white call indicator. Tone signals announce
incoming calls. Repeating tone signals
announce unanswered calls. Interrupted tone
signals indicate emergency calls.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
W41 Backbox: metal backbox supplied by
others.
CIRCUITRY
Solid state circuitry; long-life indicator lamps and
front adjustable tone module for volume
adjustment.
LISTINGS
The HM-DUTY is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical backbox with one-gang adapter for a
total depth of 2-7/8” (7.30cm), supplied by
others.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-DUTY Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-DUTY DUTY STATION
The wall recessed or surface mounted duty station shall provide visual and audible indication of normal
and emergency calls placed.
Tone signals shall announce incoming calls. Repeating tone signals shall announce unanswered calls.
Interrupted tone signals shall indicate emergency calls.
The unit shall be provided with one white call indicator and adjustable tone module for tone volume
adjustment. To insure long life and reliability, solid state signal circuitry with long-life indicator lamps
shall be used.
The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be
provided to mount the faceplate.
The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The
dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox:
4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-Duty Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
CENTRAL TONE UNIT
HM-CTU
Provides Audible Indication
Adjustable Volume Settings
Flame Retardant Faceplate
Minimum Wiring for Easy Installation
Front
DESCRIPTION
Wall recessed or surface mounted central tone
unit provides audible indication of system status /
feature activation.
CONTROLS AND INDICATORS
Tone signals indicate feature activation via
adjustable tone module.
CIRCUITRY
Solid state circuitry, front adjustable tone module
for volume adjustment provides variable
attenuation up to 20dB typical.
Tone: 93 db at 2 feet.
Rear
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O, finished in off-white supplied with nylon
mounting screws.
W41 Backbox: metal backbox supplied by
others.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical box with one-gang adapter for a total
depth of 2-7/8” (7.30cm), supplied by others.
INSTALLATION
Color-coded prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-CTU Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-CTU CENTRAL TONE UNIT
The wall recessed or surface mounted tone module shall provide audible indication of system status
and/or feature activation.
Tone signals shall indicate system status/feature activation via the adjustable tone module.
The unit shall be provided with an adjustable tone shutter for tone volume adjustment. To insure long life
and reliability, solid state signal circuitry shall be used.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be
provided to mount the faceplate.
The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm)
wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang
adapter for total depth of 2-7/8” (7.30cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-CTU Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
CENTRAL TONE UNIT / RING
HM-CTU/R
Provides Audible Indication
Adjustable Volume Settings
Distinctive Ring Tone
Flame Retardant Faceplate
Minimum Wiring for Easy Installation
Front
DESCRIPTION
Wall recessed or surface mounted central tone
unit with distinctive ring tone to provide audible
indication of system status / feature activation.
CONTROLS AND INDICATORS
Tone signals indicate feature activation via
adjustable tone module.
CIRCUITRY
Solid state circuitry, front adjustable tone module
for volume adjustment provides variable
attenuation up to 20dB typical.
Tone: 93 db at 2 feet.
Rear
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O, finished in off-white supplied with nylon
mounting screws.
W41 Backbox: metal backbox supplied by
others.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical box with one-gang adapter for a total
depth of 2-7/8” (7.30cm), supplied by others.
INSTALLATION
Color-coded prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
07/04 HM-CTU/R Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-CTU CENTRAL TONE UNIT / RING
The wall recessed or surface mounted tone module shall provide audible indication of system status
and/or feature activation.
Tone signals shall indicate system status/feature activation via the adjustable tone module.
The unit shall be provided with an adjustable tone shutter for tone volume adjustment. To insure long life
and reliability, solid state signal circuitry shall be used.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be
provided to mount the faceplate.
The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm)
wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical box with one-gang
adapter for total depth of 2-7/8” (7.30cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
07/04 HM-CTU/R Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
TONE CONTROL UNIT
HM-CTU/TCU
Provides Audible Patient Call Indication
Interrupted Tone Signal for Emergency Call
Differentiation of Type of Call Placed
UL Listed
Front
Rear
Side
DESCRIPTION
Wall recessed or surface mounted tone module
provides audible indication of normal and
emergency calls placed.
INSTALLATION
Color-coded prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided.
CONTROLS AND INDICATORS
Tone signals announce incoming calls.
Repeating tone signals announce unanswered
calls. Interrupted tone signals indicate
emergency calls.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white and supplied
with nylon mounting screws.
W41 Backbox: metal backbox supplied by
others.
CIRCUITRY
Solid state circuitry, front adjustable tone module
for volume adjustment.
LISTINGS
The HM-CTU/TCU is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical backbox with one-gang adapter for a
total depth of 2-7/8” (7.30cm), supplied by
others.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-CTU/TCU
Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-CTU/TCU TONE CONTROL UNIT
The wall recessed or surface mounted tone module shall provide audible indication of normal and
emergency calls placed.
Tone signals shall announce incoming calls. Repeating tone signals shall announce unanswered calls.
Interrupted tone signals shall indicate emergency calls.
The unit shall be provided with one adjustable tone module for tone volume adjustment. To insure long
life and reliability, solid state signal circuitry shall be used.
The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL. Nylon screws shall be provided to mount the
faceplate.
The W41 backbox shall be supplied by others. The dimensions shall be: Faceplate: 2-3/4” (6.99cm)
wide x 4-1/2” (11.43cm) high, W41 backbox: 4-11/16” (11.91cm) square electrical backbox with onegang adapter for total depth of 2-7/8” (7.30cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-CTU/TCU Issue
Design and Specifications subject to change without notice.
C
TECHNICAL
SPECIFICATIONS
TOILET EMERGENCY SWITCH
HM-TES
"PULL FOR HELP" Screened in Red On Faceplate
Positive Action Switch
High Luminosity Red LED Call Indicator
Adjustable Nylon Cord
Large Red Tassel
Front
DESCRIPTION
Wall recessed or surface mounted Emergency
Call Station with red LED call indicator and six
foot pull cord and large red tassel.
CONTROLS AND INDICATORS
When the call is placed using pull-cord activation,
the unit shall provide visual indication of
emergency call placement by flashing a red lamp
with 60 IPM (interruptions per minute) until call is
manually canceled by resetting the switch to the
inactive position.
SWITCH
Switches are positive action double pole, double
throw slide switch with distinctive red position
locator and reset knob.
Rear
INSTALLATION
Prewired with provided 6" color coded stranded
wires stripped 3/8" for ease of installation and
interconnections to the unit
Mount using only the two 6-32 x 1" nylon screws
provided.
HOUSING AND FINISH
Faceplate: Standard single gang beveled edge
molded white ABS, supplied with nylon mounting
screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high; W41 Backbox: 4-11/16”
(11.91cm) square electrical backbox with one
gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
ELECTRICAL CHARACTERISTICS
Operating Voltage: 28VDC
Current, Idle: None
Current, Operating: 25 MilliAmperes @28vdc
(excluding external lamps and / or circuits).
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-TES Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-TES TOILET EMERGENCY SWITCH
The HM-TES shall be a wall recessed or surface mounted Emergency Call Station with red LED call
indicator and six foot pull cord and large red tassel.
When the call is placed using pull-cord activation, the unit shall provide visual indication of emergency
call placement by flashing a red lamp with 60 IPM (interruptions per minute) until call is manually
canceled by resetting the switch to the inactive position.
Switch shall be positive action double pole, double throw slide switch with distinctive red position locator
and reset knob.
Operating voltage shall be 28VDC with an maximum current draw in alarm mode at 23 mA
The HM-TES shall be prewired with the provided 6" color coded stranded wires stripped 3/8" for ease of
installation and interconnections to the unit. Mount using only the two 6-32 x 1" nylon screws provided..
Faceplate shall be standard single gang beveled edge molded white ABS, supplied with nylon mounting
screws.
Dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high; W41 Backbox: 4-11/
16” (11.91cm) square electrical backbox with one gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM3B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
SINGLE PATIENT STATION
HM-SPS
Call Placement Indicator
Call Reset Button
Cordset Removal Triggers Call Placement
Standard Cordset Receptacle
UL Listed
Front
DESCRIPTION
Wall recessed or surface mounted single patient
station for use with remote call origination
cordset. Removal of the cordset originates a call
placement.
RECEPTACLE
One cordset receptacle wired to accept a single
1/4" cordset (normal call, geriatric, explosion
proof) with nurse call origination facility.
CONTROLS AND INDICATORS
One combination white call placement indicator
and call cancel button.
INSTALLATION
Color-coded, prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided.
Rear
Side
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white supplied with
nylon mounting screws.
W41 Backbox: metal backbox supplied by
others.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical box with one-gang adapter for a total
depth of 2-7/8” (7.30cm), supplied by others.
LISTINGS
The HM-SPS is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-SPS Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-SPS SINGLE PATIENT STATION
The wall recessed or surface mounted single patient station shall be for use with remote call origination
cordset.
The patient station shall be provided with a white combination call placement indicator and call cancel
button. A receptacle shall be provided, to accept single 1/4" type cordsets. A call shall be originated if
the cordset is removed from the receptacle.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL. Nylon Screws shall be provided to mount the
faceplate.
The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The
dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox:
4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-SPS Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
DUAL PATIENT STATION
HM-DPS
Call Placement Indicator
Call Reset Button
Cordset Removal Triggers Call Placement
Standard Cordset Receptacle
UL Listed
Front
DESCRIPTION
Wall recessed or surface mounted dual patient
station with individual cordset receptacles for use
with remote call origination cordset. Removal of
either cordset originates a call placement.
RECEPTACLES
Two cordset receptacles wired to accept 1/4"
cordsets (normal call, geriatric, explosion proof)
with nurse call origination facility.
CONTROLS AND INDICATORS
One combination white call placement indicator
and call cancel button.
INSTALLATION
Color-coded, prewired terminations provided.
Mount using only the two 6-32 x 1" nylon screws
provided.
Rear
Side
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white supplied with
nylon mounting screws.
W41 Backbox: metal backbox supplied by
others.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical box with one-gang adapter for a total
depth of 2-7/8” (7.30cm), supplied by others.
LISTINGS
The HM-DPS is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
Printed in U.S.A.
01/04 HM-DPS Issue C
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-DPS DUAL PATIENT STATION
The wall recessed or surface mounted dual patient station shall be for use with two remote call
origination cordsets.
The patient station shall be provided with a white combination call placement indicator and call cancel
button. Two receptacles shall be provided to accept two 1/4" type cordsets. A call shall be originated if
either cordset is removed from the receptacles.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be flame retardant ABS plastic rated 94V-O by UL. Nylon screws shall be provided to mount the
faceplate.
The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be finished in off-white. The W41 backbox shall be supplied by others. The
dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high, W41 backbox:
4-11/16” (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8” (7.30cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-DPS Issue C
Design and Specifications subject to change without notice.
DUAL PATIENT STATION
TECHNICAL
SPECIFICA
TIONS
SPECIFICATIONS
HM-DPS/2GA
Individual Call Placement Indicators
Individual Call Reset Buttons
Cordset Removal Triggers Call Placement
Standard Cordset Receptacles
UL Listed
Front
Rear
Side
DESCRIPTION
Wall recessed or surface mounted dual patient
station with individual cordset receptacles and
call indicators for use with remote call origination
cordset. Removal of either cordset originates a
call placement.
HOUSING AND FINISH
Faceplate: Flame retardant ABS plastic rated
94V-O by UL, finished in off-white supplied with
nylon mounting screws.
W42 Backbox: metal backbox supplied by
others.
RECEPTACLES
Two cordset receptacles wired to accept 1/4"
cordsets (normal call, geriatric, explosion proof)
with nurse call origination facility.
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high.
W41 Backbox: 4-11/16” (11.91cm) square
electrical box with two-gang adapter for a total
depth of 3-5/16” (8.41cm), supplied by others.
CONTROLS AND INDICATORS
Two combination white call placement indicators
and call cancel buttons.
INSTALLATION
Color-coded, prewired terminations provided.
Mount using only the four 6-32 x 1" nylon screws
provided.
LISTINGS
The HM-DPS/2GA is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-DPS/2GA
Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-DPS/2GA DUAL PATIENT STATION
The wall recessed or surface mounted dual patient station shall be for use with two remote call origination cordsets.
The patient station shall be provided with two white combination call placement indicators and call
cancel buttons. Two receptacles shall be provided to accept two 1/4" type cordsets. A call shall be
originated if either cordset is removed from the receptacles.
The unit shall be provided with color-coded prewired terminations for ease of installation. Faceplate
shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white. Nylon screws shall be
provided to mount the faceplate.
The unit shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The faceplate shall be finished in off-white. The W42 backbox shall be supplied by others. The dimensions shall be: Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high, W42 backbox: 4-11/16”
(11.91cm) square electrical box with two-gang adapter for total depth of 3-5/16” (8.41cm), supplied by
others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-DPS/2GA Issue C
Design and Specifications subject to change without notice.
Heritage MedCall Technical Specifications
MODEL HM-PBCC-8
8' BED CORD
1/4" PHONO PLUG
MOMENTARY OPERATION
CORD CLIP FOR SECURING TO BED
OR PATIENT CLOTHES
EASY CLEAN FINISH
DESCRIPTION:
The Heritage Model HM-PBCC-8 is an 8' momentary call switch for use with the Model
HM-671, HM-SPS or HM-DPS to allow call placement from a bed or chair. The Bed-Cord is
fitted with a clasp for securing the cord to the bed or patient clothes.
RESET:
Emergency call station reset is accomplished by pressing the CHECK-IN or CANCEL button
on the HM-527 or HM-S(D)PS panel. All emergency calls require this reset action to assure all
calls are verified and all initiating locations are visited.
INSTALLATION:
Model HM-PBCC-8 is installed by fully inserting the 1/4" phone plug into the bed-cord wall
plate. Removing the bed-cord from the wall plate will initiate an emergency call
Heritage MedCall, Inc
202 East Virginia Avenue
Tampa, Fl 33603
813-221-1000 ph
813-223-1405 fax
email@heritagemedcall.com
www.heritagemedcall.com
TECHNICAL
SPECIFICATIONS
SINGLE PATIENT STATION OCTAL
HM-SPS/OCT
Call Placement Indicator
Call Reset Button
Cordset Removal Triggers Call Placement
Prewired Patient Control via Octal Socket
Front
DESCRIPTION
Wall recessed or surface mounted single patient
station for use with remote call origination
cordset or patient control unit for call origination
and control of radio and television entertainment
functions. Removal of the cordset or the patient
control unit originates a call placement.
RECEPTACLE
Multi-purpose cordset receptacle fully wired to
accept any one of the following cordsets
interchangeably on a plug-in basis:
a: Patient control unit with nurse call
origination facility and remote control of TV and
radio.
b: Standard single prong combination
cordset (normal call, geriatric, explosion proof)
with nurse call origination facility.
Rear
CONTROLS AND INDICATORS
One combination white call placement indicator
and CANCEL button.
INSTALLATION
Color-coded, prewired terminations provided.
HOUSING AND FINISH
Faceplate: Standard 1-gang beveled edge
molded ABS plastic finished in gray, supplied with
non-conductive nylon mounting screws.
DIMENSIONS
Faceplate: 2-3/4” (6.99cm) wide x 4-1/2”
(11.43cm) high x 1-7/8" (4.76cm) deep; W41
Backbox: 4-11/16” (11.91cm) square electrical
backbox with one gang adapter for total depth of
2-7/8” (7.30cm), supplied by others.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-SPS/OCT Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-SPS/OCT SINGLE PATIENT STATION OCTAL
The wall recessed or surface mounted single patient station shall be for use with remote call origination
cordset or patient control unit. Facilities for TV and radio control shall be provided.
The patient station shall be provided with a white combination call placement indicator and CANCEL
button. One multi-purpose receptacle shall be provided to accept single prong type cordset or patient
control unit. A call shall be originated if the cordset or the patient control unit is removed from the
receptacle.
The unit shall be provided with color-coded prewired terminations for ease of installation. The faceplate
shall be a standard 1-gang beveled edge, molded ABS plastic finished in gray, supplied with nonconductive nylon mounting screws for maximum safety against electrical shock.
The Dimensions shall be: Faceplate: 2-3/4” (6.99cm) wide x 4-1/2” (11.43cm) high x 1-7/8" (4.76cm)
deep; W41 Backbox: 4-11/16” (11.91cm) square electrical backbox with one gang adapter for total
depth of 2-7/8” (7.30cm), supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM1B Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
ENTERTAINMENT CONTROL UNIT
HM-ECU
Allows Remote Control of TV Set
Selection of Five Audio Channels
Connections via Prewired Connector
Compact Design
DESCRIPTION
Wall recessed or surface mounted Radio/TV and
comfort control, used with patient control unit and
patient station, for remote control of television
set, bed position, room lighting, drapes and one
additional function, and for selection of five radio
or other audio programs.
APPLICATIONS
For television sets equipped for automatic
adjustment of color and tint, and audio
entertainment distribution system providing five
program channels.
POWER REQUIREMENT
One Model HM-24V-2.5A Power Supply supports
a combination of up to 80 radio/TV selector
circuits.
INSTALLATION
The HM-ECU shall mount on a two-gang
faceplate using a standard two-gang electrical
box, supplied by others. For ease of installation
and maintenance, the unit will plug into prewired
connector using 1-HM-ECUP.
HOUSING AND FINISH
Circuit Board mounted to metal bracket on nonconductive standoffs.
DIMENSIONS
Maximum dimensions shall be 3-5/8" (9.2cm)
wide x 3-1/8" (8 cm) deep x 1-1/2" (3.81 cm)
high.
LISTINGS
The HM-ECU is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-226-0091 (voice), 813-228-8622 (fax)
www.heritagemedcall.com
02/03 HM-ECU Issue A
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-ECU ENTERTAINMENT CONTROL UNIT
The wall recessed or surface mounted radio/TV selector shall be used with patient control unit and
patient station for remote control of television set and selection of five radio or other audio programs.
The radio/TV selector shall operate with television sets equipped for automatic adjustment of color and
tint, and an audio entertainment distribution system providing up to five program channels.
The HM-ECU is UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
One Model HM-24V-2.5A Power Supply shall support a combination of up to 80 radio/TV selector
circuits.
For ease of installation and maintenance, the unit shall plug into prewired connector. All components
shall be mounted on a faceplate designed to fit into the opening of a standard two-gang electrical
backbox. For maximum safety against electrical shock, the faceplate shall be mounted using nonconductive screws.
The HM-ECU shall mount on a two-gang faceplate using a standard two-gang electrical box, supplied by
others. For ease of installation and maintenance, the unit will plug into prewired connector using 1-HMECUP ordered separately.
Maximum dimensions shall be 3-5/8" (9.2 cm) wide x 3-1/8" (8 cm) deep x 1-1/2" (3.81 cm) high.
© 2002 Heritage MedCall, Inc.
Printed in U.S.A.
02/03 HM-ECU Issue A
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
PRE-WIRED CONNECTORS
HM-ECUP
Single In-line Polarized Connector
Color Coded Tined Leads
22 Gauge Wire 0.10" Center
Nylon Connector Housing
DESCRIPTION
INSULATION
Connectors used in the Heritage Visual Nurse Call
Systems (VNS) for the HM-ECU Entertainment Control
Unit.
Color coded semi-rigid PVC insulation.
Maximum thickness .41mm.
GAUGE AND TYPE
CONNECTOR
22 gauge stranded copper wire with tinned leads.
Rated temperature: 80º C
Rated voltage: 300 volts
UL listed style 1007 wire.
Single in-line polarized nylon connector.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-ECUP Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-ECUP PRE-WIRED CONNECTORS
The HM-ECUP connectors shall be used in the Heritage Medcall Visual Nurse Call Systems (VNS) for the
connection to the HM-ECU Entertainment Control Unit.
The wire shall be of 22 gauge stranded copper wire with tinned leads with a rated temperature of 80º C and a voltage
rating of 300 volts and UL listed 1007.
Insulation shall be color coded semi-rigid PVC insulation with a maximum thickness of .41mm.
Connector shall be nylon single in-line polarized connector.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-ECUP Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
EMERGENCY SWITCH COVER
HM-ESC
Low Profile
Clear Acrylic Cover
Cutout on Bottom
DESCRIPTION
Provides protection from inadvertent operation of
emergency and code blue switches.
INSTALLATION
Cover attached using screw or hook and loop
fasteners as appropriate.
HOUSING
Formed clear acrylic cover with clear acrylic
hinge. Cutout on cover bottom allows clearance
for pull cords or bed cords.
DIMENSIONS
3.5" W (88.9mm) X 6.6" H ( 167.64mm) X 1.36"
(34.54mm) standard.
Contact Heritage for other special order sizes.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-ESC Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-ESC EMERGENCY SWITCH COVER
The HM-ESC shall be used to provide protection from inadvertent operation of emergency and code blue
calls.
Housing shall be made of formed clear acrylic cover with clear acrylic hinge. Cutout on cover bottom
allows clearance for pull cords or bed cords.
The HM-ESC shall be attached using screw or hook and loop fasteners as appropriate.
The dimensions shall be 3.5" Wide (88.9mm) X 6.6" High ( 167.64mm) X 1.36" Deep (34.54mm)
standard.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-ESC Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
FLASHER UNIT
HM-F3
Three Levels of Operation
Terminal Block for Connections
Removable Protective Cover
Metal Base for Easy Wall Mounting
Rugged Metal Housing
Top
Side
DESCRIPTION
Three level flasher assembly provided in a
surface mounted housing.
INSTALLATION
Terminal block for wire connections with holes in
flasher base for wall mounting.
CIRCUITRY
Solid state for maximum reliability.
HOUSING
Metal base and removable protective metal
cover.
OPERATING VOLTAGE
24 volts DC. No AC outlet required.
OUTPUT RATING
4 Amps at 24 - 28 volts DC.
FLASH RATES
Three rates to annunciator panel with associated
duty line:
Priority
High
Medium
Low
To Annunciator
Duty Line
60 Pulses Per Min. (PPM)
60 PPM
30 PPM
30 PPM
Steady
6 PPM
FINISH
Metal cover finished in black.
DIMENSIONS
8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 113/16” (4.60cm) deep.
LISTINGS
The HM-DPS/2GA is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-F3 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-F3 FLASHER UNIT
The three level flasher shall consist of solid state circuitry in a surface mounted housing. The flasher
shall operate on 24-28 volts DC and shall not require an AC outlet. The flasher output rating shall be 4
amps at 24-28 volts DC.
The HM-F3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under File
E157381.
The flasher unit shall provide three output rates to the annunciator panel, and associated duty line. The
three rates are:
Priority
High
Medium
Low
© 2004 Heritage MedCall, Inc.
To Annunciator
60 Pulses Per Min. (PPM)
30 PPM
Steady
Printed in U.S.A.
Duty Line
60 PPM
30 PPM
6 PPM
01/04 HM-F3 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
LAMP AND TONE CONTROL UNIT
HM-T1
Single Level Call
Terminal Block for Connections
Removable Protective Cover
Metal Base for Easy Wall Mounting
Rugged Metal Housing
DESCRIPTION
Single level lamp and tone control unit for multiple
call locations to provide call event activation or
de-activation from any call location.
TONE RATES
Length: 0 - 1 seconds
Rate: 1- 60 seconds
CIRCUITRY
Solid state for maximum reliability.
INSTALLATION
Terminal block for wire connections with holes in
base for wall mounting.
OPERATING VOLTAGE
24 volts DC.
HOUSING
Natural aluminum finished box 0.040 thickness.
OUTPUT RATING
Circuit draw 20 ma.
Maximum draw 2 amps.
DIMENSIONS
5.25" L X 3.0" W X 2.12" H
INDICATORS
Power Indication
Lamp Active
Tone Active
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
07/04 HM-T1
Printed in U.S.A.
MODEL HM-T1 LAMP AND TONE CONTROL UNIT
The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing.
The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2
amps at 24-28 volts DC.
The lamp and tone control unit shall have an adjustable tone duration from zero to one second.
The lamp and tone control unit shall have an adjustable tone rate from one to sixty seconds.
Installation shall consist of six position terminal block for wire connections and housed in a natural
aluminum finished box 0.040" thickness.
Dimmensions of housing shall be 5.25" L X 3.0" W X 2.12" H.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
07/04 HM-T1
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
LAMP AND TONE CONTROL UNIT
HM-T4
Four Discrete Lamp Circuits
One Tone Control Circuit
Terminal Block for Connections
Removable Protective Cover
Metal Base for Easy Wall Mounting
Rugged Metal Housing
DESCRIPTION
The HM-T4 is a unique low cost device to control
a simple light or light and tone signaling system
with four discrete lamp circuits. The HM-T4
allows one or more switches to turn on and off
lights from multiple locations with the use of
simple lighted pushbutton switches. The HM-T4
has a circuit to drive tone units to audibly
annunciate when a button is activated. The tone
circuit has adjustments to vary both the length of
the tone and how often it is repeated. The HM-T4
allows you to choose which circuit controls the
tone units.
CIRCUITRY
Solid state for maximum reliability.
OPERATING VOLTAGE
24 volts DC.
INDICATORS
Power Indication
Lamp Active - (4)
Tone Active
TONE RATES
Length: 0 - 1 seconds
Repeat: 1- 60 seconds
INSTALLATION
Terminal block for wire connections with holes in
base for wall mounting.
HOUSING
Metal cover finished in black.
DIMENSIONS
8-1/4” (20.95cm) wide x 6-1/8” (15.56) high
1-13/16” (4.60cm) deep.
OUTPUT RATING
Circuit draw 20 ma.
Maximum draw 2 amps.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
08/04 HM-T4
Printed in U.S.A.
MODEL HM-T4 LAMP AND TONE CONTROL UNIT
The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing.
The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2
amps at 24-28 volts DC.
The lamp and tone control unit shall have an adjustable tone duration from zero to one second.
The lamp and tone control unit shall have an adjustable tone repeat rate from one to sixty seconds.
Installation shall consist of twelve position terminal block for wire connections and housed in a metal box
finished in black.
Dimmensions of housing shall be 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 1-13/16” (4.60cm)
deep.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
08/04 HM-T4
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
LAMP AND TONE CONTROL UNIT
HM-T8
Eight Discrete Lamp Circuits
One Tone Control Circuit
Terminal Block for Connections
Removable Protective Cover
Metal Base for Easy Wall Mounting
Rugged Metal Housing
Link multiple HM-T8's together
DESCRIPTION
The HM-T8 is a unique low cost device to control
a simple light or light and tone signaling system
with eight discrete lamp circuits. The HM-T8
allows one or more switches to turn on and off
lights from multiple locations with the use of
simple lighted pushbutton switches. The HM-T8
has a circuit to drive tone units to audibly
annunciate when a button is activated. The tone
circuit has adjustments to vary both the length of
the tone and how often it is repeated. The HM-T8
allows you to choose which circuit controls the
tone units. Link multiple HM-T8 together for
single tone annunciation.
CIRCUITRY
Solid state for maximum reliability.
OPERATING VOLTAGE
24 volts DC.
INDICATORS
Power Indication
Lamp Active - (8)
Tone Active
TONE RATES
Length: 0 - 1 seconds
Repeat: 1- 60 seconds
INSTALLATION
Terminal block for wire connections with holes in
base for wall mounting.
HOUSING
Metal cover finished in black.
DIMENSIONS
8-1/4” (20.95cm) wide x 6-1/8” (15.56) high
1-13/16” (4.60cm) deep.
OUTPUT RATING
Circuit draw 20 ma.
Maximum draw 2 amps.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
08/04 HM-T8
Printed in U.S.A.
MODEL HM-T8 LAMP AND TONE CONTROL UNIT
The lamp and tone control unit shall consist of solid state circuitry in a surface mounted housing.
The lamp and tone control unit shall operate on 24-28 volts DC. The output rating shall be maximum 2
amps at 24-28 volts DC.
The lamp and tone control unit shall have an adjustable tone duration from zero to one second.
The lamp and tone control unit shall have an adjustable tone repeat rate from one to sixty seconds.
Installation shall consist of a twenty two position terminal block for wire connections and housed in a
metal box finished in black.
Dimmensions of housing shall be 8-1/4” (20.95cm) wide x 6-1/8” (15.56) high x 1-13/16” (4.60cm)
deep.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
08/04 HM-T8
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
ZONE CONTROL MODULE
HM-ZCM3
Controls Three Separate Zone Dome Lights
Responds to All Normal Calls in Zone
Responds to All Emergency Calls In Zone
Solid State Circuitry
Mounts on Standard Two-Gang Backbox
DESCRIPTION
Surface or flush mounted zone light control for
use in conjunction with three zone lamps. Used
in locations where the nurse control station and/
or annunciator panel and specific care lights are
not visible to alert the nursing personnel of calls
placed by patients. Normal calls are indicated by
steady illumination of a lamp. Emergency calls
are indicated by flashing lamp.
REQUIREMENTS
One zone light control and three dome lights
required for every three zones in the system.
CIRCUITRY
Solid state devices mounted on an epoxy glass
printed circuit board.
HOUSING AND FINISH
Faceplate: Flame retardant ABS platic rated
94VV-O by UL, finished in off-white.
W42 Backbox: Metal backbox supplied by
others.
DIMENSIONS
Faceplate: 4-9/16” (11.59cm) wide x 4-1/2”
(11.43cm) high; W42 Backbox: 4-11/16”
(11.91cm) square electrical backbox with two
gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
LISTINGS
The HM-ZCM3 is UL and CUL listed Hospital
Signaling Equipment / Nurse Call Equipment
under File E157381.
INSTALLATION
Miniature terminal block with screw terminals and
barriers.
Heritage MedCall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-ZCM3 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-ZCM3 ZONE CONTROL MODULE
The wall recessed or surface mounted zone light control shall be used in conjunction with three zone
lamps in locations where the nurse control station and/or annunciator panel and specific care lights are
not visible to alert nursing personnel of calls placed by patients. Normal calls shall be indicated by
steady illumination of a lamp. Emergency calls shall be indicated by flashing lamp.
The HM-ZCM3 shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment under
File E157381.
The HM-ZCM3 Zone Control Module and three zone lamps shall be required for every three zones in the
system. For reliability, solid state devices and epoxy glass printed circuit board shall be used. For ease
of installation and maintenance, miniature terminal block and screw terminals with barriers shall be
provided.
The HM-ZCM3 faceplate shall be flame retardant ABS plastic rated 94V-O by UL, finished in off-white.
The dimensions shall be: Faceplate: 4-9/16” (11.59cm) wide x 4-1/2” (11.43cm) high; W42 Backbox:
4-11/16” (11.91cm) square electrical backbox with two gang adapter for total depth of 3-5/16” (8.41cm),
supplied by others.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-ZCM3 Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
ANNUNCIATOR LAMP
HM-28ESB
LongLife
High Visibility
Low Current Draw
DESCRIPTION
Incandescent T-2 Telephone Slide Base Type 5
(short) Lamp.
INDICATOR
Mean Spherical Candle Power of 1500. Life
expectancy of 6000 hours. Filament Type C-2F.
ELECTRICAL CHARACTERISTICS
Voltage Rating: 28 volts DC
Current Draw: 45mA.
DIMENSIONS
0.28” (7.112mm) wide x 0.915” (23.24mm) high
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
03/03 HM-28ESB Issue A
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-28ESB ANNUNCIATOR LAMP
The HM-28ESB shall be a incandescent style T-2 Telephone Slide Base Type 5 (short) lamp.
Lamp shall have a minimum rating of 1500 mscp (mean spherical candle power) and life expectancy of
6000 hours. Filament shall consist of type C-2F.
The HM-28ESB shall operate at a maximium voltage of 28 volts DC at 0.45 mA.
The dimensions shall be 0.28” (7.112mm) wide x 0.915” (23.24mm) high.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-28ESB Issue C
Design and Specifications subject to change without notice.
TECHNICAL
SPECIFICATIONS
PUSH BUTTON PANEL BULBS
HM-85
LongLife
High Visibility
Low Current Draw
DESCRIPTION
Incandescent T-1 3/4 Wedge Base style bulb.
ELECTRICAL CHARACTERISTICS
Voltage Rating: 28 volts DC
Current Draw: 40mA.
INDICATOR
Mean Spherical Candle Power of 0.300. Life
expectancy of 7000 hours. Filament Type C-2F.
DIMENSIONS
0.230” (5.842mm) wide x 0.800” (20.32mm) high.
Heritage Medcall, Inc.
202 East Virginia Avenue, Tampa, FL 33603
813-221-1000 (voice), 813-223-1405 (fax)
www.heritagemedcall.com
01/04 HM-85 Issue C
Printed in U.S.A.
ARCHITECTS’ AND ENGINEERS’ SPECIFICATIONS
MODEL HM-85 PUSHBUTTON PANEL BULB
The HM-85 shall be a incandescent style T-1 3/4 Wedge Base style bulb.
Lamp shall have a minimum rating of .300 mscp (mean spherical candle power) and life expectancy of
7000 hours. Filament shall consist of type C-2F.
The HM-85 shall operate at a maximum voltage of 28 volts DC at 0.40 mA.
The dimensions shall be 0.230” (5.842mm) wide x 0.800” (20.32mm) high.
© 2004 Heritage MedCall, Inc.
Printed in U.S.A.
01/04 HM-85 Issue C
Design and Specifications subject to change without notice.
Download