Echo and its components shown in this brochure have United States, Canadian and International patents pending. SPI Lighting, Power Tray and Shapes are registered trademarks Copyright 1999. Specification subject to change without notice. All rights reserved. Printed in the U.S.A. Simplified form, expanded flexibility, superior performance . . . the evolution continues. ECHO SPI Lighting Inc. warrants its products free from defective material and workmanship. SPI will repair or replace at its option, without charge, at our factory within a period of one year from the date of shipment and only after prior written return authorization has been granted. This warranty does not apply to products which have been damaged in shipping, installed or maintained improperly, or altered or repaired outside of SPI’s factory. This warranty only covers equipment manufactured by SPI Lighting Inc. and does not include transportation, labor or installation charges, nor does it apply to any components not manufactured by SPI Lighting Inc. For complete Warranty Information and Term and Conditions of Sale, please contact SPI Lighting or your local representative. ECHO SPI SPI Lighting 10400 North Enterprise Drive Mequon, Wisconsin 53092 E10-00 262 242 1420 FAX 262 242 6414 E-mail spi@spilighting.com www.spilighting.com © 2000 SPI Lighting ECHO ■ Technical ■ Credits SPI’s expanded Echo Series is not a repetition, but an evolution. Adding fluorescent lamping to metal halide and quartz-halogen. Moving outside with new weather-resistant housings. Integrating ballast options to simplify form. And offering a palette of sizes, housings and mounting methods that make Echo suitable for numerous applications, blending functional design with superior performance — again. And again and again. 1 INTRODUCTION Standard Remote Ballast Kit ■ ■ ■ ■ ■ ■ ■ ■ Remote Dual tap, 120 / 277 volt operation Encased and potted Thermally protected CWA-HPF design End-mounted wire compartment 16 gauge mounting legs Field assembly required C Installation: Architects: Engineering: Lighting: Photography: Fixture(s): Bellevue Regional Library / Bellevue, WA Zimmer Gunsul Frasca Partnership Sparling Associates Candela, Consultant Timothy Hursley ECR 3803 / 1000 BT37 MH 1 Installation: Architects: Engineering: Photography: Fixture(s): Buffalo Bills Training Center / Buffalo, NY Duchscherer Oberst Design Wilson, Klaes, Brucker & Worden Paul Maze, Phototech Studio EDR 3803 SM and DC / 1000 BT37 MH Installation: Architects: Engineering: Photography: Fixture(s): Rockford High School / Rockford, MI Greiner, Inc. Greiner, Inc. Phil Schaafsma Photography EER 2403 / Scoop: 175 ED17 Med MH 10 Remote Ballast Tray - RPI ■ ■ ■ ■ ■ ■ 2-3 ■ COMPONENTS / APPLICATIONS Optional Remote Dual tap, 120 / 277 volt operation Encased and potted Thermally protected CWA-HPF design Universal mounting brackets for 1/2” EMT, lathing channels or hanger brackets 2 12 ■ ■ Housing, mounting bracket and fasteners constructed of non-ferrous materials Small electrical components such as lamp and sockets may contain ferrous materials Installation: 4 Photography: Tom Davenport, BBD Fixture(s): EDR SR 1403 / Semi-Recessed: 150 T6 RSC MH Fuse Option - F ■ ■ ■ Sized appropriately for electrical requirements Fuse holder and fuse supplied by factory Some fuse holders may require field installation 11 5 O’Hare International Airport - Terminal 5, Rotunda Chicago, IL Architects: Group One Design: Perkins & Will, Heard & Associates and Consoer Townsend & Associates Engineering: Hansen Palmer Associates, Ltd. Lighting: David A. Mintz Photography: Nick Merrick, Hedrich-Blessing Fixture(s): EDR 5603 with column-mount bracket / (2) 400 T15 MH 6 Installation: Architects: Photography: Fixture(s): Ford XL Training Center / Allen Park, MI Palladia Architects, Inc. Dave Knox, Regan Productions ECR QC 1743 / 350 HIR T3 RSC QTZ 7 Installation: Architects: Lighting: Photography: Fixture(s): Corporate Office / Chicago, IL Powell/Kleinschmidt Inc. Gary Steffy Lighting Design Inc. Jon Miller, Hedrich Blessing EDR 4403 / 150 T6 RSC MH 8 Installation: 9 Installation: Standby Lighting Option - Q ■ ■ ■ Emergency Lighting Option, fluorescent - EM ■ 4-5 SIZE 1 6-9 SIZE 1.5 10 - 15 SIZE 2 16 - 17 SIZE 3 18 - 20 Accessories 100 watt quartz lamp and switch relay Provides temporary lighting, when power is on, until the metal halide lamp reaches 30% of lighting output Remote mounted relay with remote ballast fixtures ECR and EDR ■ ■ ■ ■ ■ 1 A minimum of 50 fc is achieved with 1000 watt Echos, stem-mounted 56 feet above the floor. Every sixth fixture is double-clustered for additional light on the running track. ■ ■ Integral ballast Remote ballast for 12” and 19” fixtures Operates lamp a minimum of 90 minutes at approximately 30% output in emergency mode Operates until AC power restored Automatically recharges UL Listed and exceeds NEC/NFPA-LSC emergency illumination requirements Remote mount charge indicator light and test switch For integral mounting of indicator light, please consult factory Dimming, fluorescent - DB ■ ■ ■ VARIATIONS / CUSTOM International Market ■ 21 Optional Mounting 22 - 23 Semi-Recessed 24 - 27 ShapesTM 28 - 29 Cove Mount 180˚ ■ 150˚ ■ 135˚ 10095 15142 90˚ 20190 ■ HID ballasts may hum slightly due to the magnetic action in the core and coil assembly. This hum may be amplified by the resonant qualities of its surroundings such as ceiling, walls, floors or furnishings. Careful consideration of these components within the lighting design will ensure the quietest installation possible. For “library quiet” installations, remote mount ballast or please consult factory. 13 Bay View Branch Library, Milwaukee Public Library Milwaukee, WI Architects: Engberg Anderson Engineering: Harwood Engineering, Consultants Photography: Morley Johnson Fixture(s): EDR 5603 / (2) 400 T15 MH Northwest Community Hospital, Wellness Center / Arlington Heights, IL Architects: OWP & P Engineering: Environmental Systems Design Inc. Lighting: Gerry Zekowski Photography: Paul Schlissman, 1996 Fixture(s): EDT 5603 / (2) 400 T15 MH Installation: Architects: Engineering: Photography: Fixture(s): Waukesha Memorial Hospital / Waukesha, WI The Zimmerman Design Group Uihlein Electric Company, Inc. Purcell Imaging EER 2603 / Scoop: 400 T15 MH ■ 37 E10-00 5047 Available for HO and VHO FL lamps; consult factory Remote fixtures may require additional cords ballast Ballast Sound 105˚ PHOTOMETRY & APPLICATION / TECHNICAL / CREDITS 50 and 60 Hz ballasts available in different voltages; please consult factory Cold Weather Ballasts 165˚ 120˚ 30 - 37 Ballast available for 26 QUAD FL, 32 T8 FL and 39, 40, 50 TT FL lamps only Dimming range: 10% - 100% Please consult factory for dimming system compatibility Installation: ECHO ECHO Boeing Customer Service Center, Flight Simulator Area Renton, WA Architects: Callison Photography: Fred Licht 1995 Fixture(s): ECR 3803 / 1000 BT37 MH 3 MRI Construction - MRI Echo offers five diameters, ranging from 3" to 161/2", in solid or perforated metal or an extruded aluminum housing that allows the design to be carried outside. The addition of decorative ShapesTM or custom-made shrouds enables Echo to compliment any environment. Echo’s highly efficient, adjustable luminaires project a controlled pattern of light across a horizontal or vertical surface. Versatility is Echo’s hallmark. The optical systems incorporate the latest in lamp technology, including Echo offers a variety of housing, optical and ballast options. (L-R: Extruded aluminum housing with wet location lens assembly, dual-lamp optical in perforated steel fixture and integral ballast within an extruded aluminum housing) metal halide, halogen and new fluorescent lamps. Integral and remote magnetic or electronic ballast options simplify form and allow for continuity of design throughout a space. Echo Illumination Traditional Illumination UNIQUE FEATURES 2 Scoop ShapesTM compliment the architectural lines of this hallway Echo can be wall, ceiling, pendant or pier-mounted, in a full range of applications. Sizes .5, 1 and 1.5 offer compact, unobtrusive lighting for small to medium spaces with lower ceilings - offices, conference rooms, corridors, lobbies and coves. Size 2 is ideal for larger, high-ceiling spaces such as atriums, gymnasiums, natatoriums, libraries, open offices and lobbies. Size 3 is designed for even larger spaces: malls, atriums and transportation and sports facilities. Single and multiple lamp configurations suit Echo to a variety of lighting techniques. From accent to ambient lighting, Echo offers the opportunity to make an architectural statement with high-quality illumination. ■ 1 ECHO ■ Components The key to Echo’s consistent performance lies in the combination of lamp type, optical designs and lens options. Each reflector is designed around specific lamps and precision-formed from prefinished reflective material, for high-quality illumination — indirect or direct, inside or out. 3 Size 3 Echo fixtures provide even illumination and virtually no shadows in this training area The HID and quartz asymmetric optical combines a premium 95% reflective hammertone material with a clear lamp to deliver high lumen output with no striations. Fluorescent symmetric and asymmetric reflectors are formed from prefinished low iridescent specular aluminum, used with compact or linear fluorescent lamps to achieve up to 85% efficiency. Integral and remote ballasting are available. The optical system and/or ballast compartment are mounted between two die-cast aluminum end caps and protected by the housing. This arrangement promotes safe, cool operation and simplifies fixture installation and design. Echo offers three standard housing options in solid or perforated metal and extruded aluminum. The perforated housing, an SPI innovation, adds ventilation in higher ambient temperatures and renders a subtle sparkle of light to give the exposed surface an architectural presence. Extruded aluminum housings, in several standard as well as custom lengths up to eight feet, are ideal for wet location or MRI applications. The center mounting point on Echo’s end cap allows the fixture to be rotated and precisely adjusted. Indoor fixtures can be painted any of SPI’s standard polyester powder coat finishes. Wet location fixtures are available in most of our standard finishes. Custom matched colors are available; please consult factory. 2000 SPI Lighting ■ 2 ■ Special Applications 4 Semi-recessed Echos accent artwork in an office space While Echo is appropriate wherever a uniform wash of light is desired, the expanded series presents opportunities in special applications. Sizes .5 and 1.5 fixtures introduce compact and linear fluorescent lamps in three and six-inch diameter housings that provides efficient, uniform wall-washing illumination for corridors, offices, conference rooms, merchandise displays and galleries. The extruded aluminum housing gives Echo the structural integrity and corrosion resistance for wet locations, carrying the lighting design from inside to outside. Integral components make for a simple design and easy installation. Gasketing between the lens and housing offers excellent compression resistance, memory retention and sealing capability. The aluminum frame of the HID and quartz glass lens assembly is held secure by stainless steel hardware. Fluorescent fixtures have a unique “snap tight” acrylic lens. All Echo .5, 1.5 and 2 units with the “WL” accessory are UL Listed for US and Canadian wet location requirements. 5 Wet location lens detail Echos are column-mounted with custom brackets in this rotunda Virtually any mounting variation can be accommodated simply by changing the position of Echo’s yoke bracket, or by using custom brackets for special applications such as column or corner mounting. With ceiling, wall or pier mounting, light can be directed in a controlled pattern to bring out the texture of a wall, highlight a work of art, accentuate a domed or highly detailed ceiling... and comfortably illuminate the space below. ■ 3 ECHO 1 ■ ECR / EDR - Remote Compact five-inch diameter housings are solid or perforated. Quartz-halogen lamps provide excellent color rendition and allow for easy dimming. Doubled-ended metal halide lamps deliver exceptional light output in a compact optical package. 6 Echo quad-clusters are pendant mounted in a training area ECR 1723 120 BFT EDR 1723 120 BFT Housing Construction ■ ■ ■ ■ ■ ■ ECR - perforated, 18 gauge roll formed steel EDR - solid, 18 gauge roll formed steel Die cast aluminum end caps with rotation stops Flush mounted fasteners UL Listed for US and Canada, damp location Decorative ShapesTM on pp. 24 - 27 Reflector Painted Finish Up to 74.5% efficient / asymmetric ■ Maximum candlepower between 25° and 45° above horizontal ■ Segmented, 95% reflective, specular clear hammertone aluminum ■ Impact and heat resistant, tempered, textured glass lens ■ Ballast MRI Construction - (MRI) ECR / EDR - Remote ■ Magnetic, 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ ■ Mounting ■ ■ ■ ■ 2000 SPI Lighting ■ 4 Yoke bracket die formed, 14 gauge steel Field adjustable housing Surface mount over a 4" box Cover plate conceals wiring and mounting hardware ■ ■ ■ ■ Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ECR / EDR - perforated or solid, roll formed aluminum housing Die cast aluminum end caps Yoke bracket die formed aluminum EDR 1733 120 BFT CS BFT LENGTH FIXTURE ● 10.5” ● ECR EDR NUMBER ● ● ● ● ● 1203 1403 1723 1733 1743 LAMPING PHOTOMETRY VOLTAGE (1) 70 T6 RSC MH (1) 150 T6 RSC MH (1) 150 T4 DC BAY QTZ (1) 300 T3 RSC QTZ (1) 350 HIR T3 RSC QTZ E435-3R E435-3R E435-10R E435-10R E435-10R ● FINISH 120 / 277 ● BFT ECR CS - Cutoff shield CM - Ceiling mount ● PM - Pier mount ● DC - Double cluster ● TC - Triple cluster ● QC - Quad cluster ● SM - Stem mount * Specify stem length on cluster and stem mount fixtures: SM 24 ● RPI - Remote ballast support tray † ● MRI - Non-magnetic fixture † ● F - Fuse option (MH) † † Technical information, page 37 ● ● ● 120 Indirect orientation only SAMPLE: ACCESSORIES pp. 18 - 20 1723 120 BFT CM PHOTOMETRICS E435-3R E435-10R 180˚ 180˚ 165˚ 165˚ 150˚ 150˚ 135˚ 135˚ 120˚ 120˚ 105˚ 105˚ 2079 4158 6237 90˚ 8316 1924 3849 5774 90˚ 7699 ECR 1723 120 BFT DIMENSIONS 51/4" 12" 41/2" 2" Auxiliary Mounting Holes 61/2" Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 70MH = 20’, 150MH = 20’. Consult factory for additional information. SIZE 70 MH 150 MH A 3” 3” B 133/8” 161/16” C C 33/16” 33/16” A B 101/2" 51/4" Damp location ■ 5 ECHO 1.5 ■ ECR / EDR / EXR - Remote New six-inch diameter housings are available in three styles: solid or perforated metal and all-new extruded aluminum. Lamping options include metal halide and quartz-halogen lamps for exceptional light output and color rendition. 7 Echo provides ambient lighting in this conference room ECR 4203 120 BFT EDR 4203 120 BFT Housing Construction ■ ■ ■ ■ ■ ■ ■ ECR - perforated, 18 gauge roll formed steel EDR - solid, roll formed aluminum EXR - extruded .125 aluminum Die cast aluminum end caps with rotation stops Flush mounted fasteners UL Listed for US and Canada, damp location Decorative ShapesTM on pp. 24 - 27 Ballast MRI Construction - (MRI) ECR / EDR / EXR - Remote ■ Magnetic, 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ Painted Finish ■ Mounting ■ ■ ■ ■ Yoke bracket die formed, 14 gauge steel Field adjustable housing Surface mount over a 4" box Cover plate conceals wiring and mounting hardware Reflector ■ ■ ■ ■ 2000 SPI Lighting ■ 6 Up to 74.5% efficient / asymmetric Maximum candlepower between 25° and 45° above horizontal Segmented, 95% reflective, specular clear hammertone aluminum Impact and heat resistant, tempered, textured glass lens ■ ■ Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ ■ ECR / EDR - perforated or solid, roll formed aluminum housing Die cast aluminum end caps with rotation stops Yoke bracket die formed aluminum Wet Location Construction - (WL) EXR - extruded aluminum housing only, UL Listed, for US and Canada, wet location ■ Die cast aluminum end caps with rotation stops ■ Tamper-resistant fasteners ■ Aluminum lens frame with gasketing ■ Yoke bracket die formed, 14 gauge stainless steel ■ Flexible weatherproof power cord with watertight fittings, black standard ■ MH ballasts not WL Listed, consult factory ■ Consult factory for ground mount ■ LENGTH FIXTURE ● 12” ● ● NUMBER ECR EDR EXR ● ● ● ● ● 4203 4403 4723 4733 4743 LAMPING PHOTOMETRY E435-3R (1) 70 T6 RSC MH E435-3R (1) 150 T6 RSC MH E435-10R (1) 150 T4 DC BAY QTZ E435-10R (1) 300 T3 RSC QTZ** (1) 350 HIR T3 RSC QTZ** E435-10R VOLTAGE ● 120 / 277 FINISH ● BFT ACCESSORIES pp. 18 - 20 CS - Cutoff shield, consult for WL CM - Ceiling mount ** ● PM - Pier mount ** ● SM - Stem mount ** Specify stem length: SM 24 * Consult factory for clusters ● HM - Hub mount ● HMSQ - Square hub mount ● WL - Wet location construction, EXR only † ● RPI - Remote ballast support tray ** † ● MRI - Non-magnetic fixture † ● F - Fuse option (MH) † ** Not available for WL fixture † Technical information, page 37 ● ● ● 120 Indirect orientation only EDR 4403 120 BFT CS BFT SAMPLE: EXR 4403 120 BFT WL PHOTOMETRICS E435-3R E435-10R 180˚ 180˚ 165˚ 165˚ 150˚ 150˚ 135˚ 135˚ 120˚ 120˚ 105˚ 2079 4158 6237 90˚ 8316 105˚ 1924 3849 5774 90˚ 7699 EXR 4403 120 BFT WL DIMENSIONS 12" Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 70MH = 20’, 150MH = 20’. Consult factory for additional information. Auxiliary Mounting Holes SIZE 70 MH 150 MH WL 51/4" 57/16" 2" 511/16" 2" 71/2" 81/2" A 3” 3” B 133/8” 161/16” C C 33/16” 33/16” A B 12" 6" ■ 7 ECHO 1.5 ■ ECI / EDI / EXI - Integral Integral ballast simplifies form and installation. New six-inch diameter housings come in three styles: solid, perforated or all-new extruded aluminum in several standard as well as custom lengths. Compact and linear fluorescent lamps offer efficient wall-washing and accent illumination. Asymmetric and symmetric reflectors increase lighting flexibility. EXI 4813 120 BFT ECI 4843 120 BFT EDI 4803 120 BFT Housing Construction ■ ■ ■ ■ ■ ■ ■ ECI - perforated, 18 gauge roll formed steel EDI - solid, roll formed aluminum EXI - extruded .125 aluminum Die cast aluminum end caps with rotation stops Flush mounted fasteners UL Listed for US and Canada, damp location Decorative ShapesTM on pp. 24 - 27 Ballast - HID ■ ■ ■ ■ ■ ■ Mounting ■ ■ ■ Yoke bracket die formed, 14 gauge steel; two-piece for fixtures over 27” in length Field adjustable housing Surface mount over a 4" box Cover plate conceals wiring and mounting hardware ■ ■ ECI / EDI / EXI - Integral Electronic,120 volt operation / 277 volt optional Class “A” sound rating and low harmonic distortion Thermally protected Minimum starting temperature 0° F Ballast Notes 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ Reflector - HID ■ ■ ■ ■ Painted Finish ■ ■ ■ Ballast - Fluorescent ■ ■ ECI / EDI / EXI - Integral Magnetic, 120 volt operation; consult factory for other voltages Open core and coil CWA-HPF design 74.5% efficient / asymmetric Maximum candlepower between 25° and 45° above horizontal Segmented, 95% reflective, specular clear hammertone aluminum Impact and heat resistant, tempered, textured glass lens Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes Wet Location Construction - (WL) EXI - extruded aluminum housing only, UL Listed, for US and Canada, wet location ■ Die cast aluminum end caps with rotation stops ■ Tamper-resistant fasteners ■ Aluminum lens frame with gasketing, MH ■ “Snap tight” acrylic lens, FL ■ Flexible weatherproof power cord with watertight fittings, black standard ■ Yoke bracket die formed, 14 gauge stainless steel; two-piece for fixtures over 27” in length ■ Reflector - Fluorescent Asymmetric ■ ■ ■ Up to 85% efficient Pre-finished, 85% reflective, low iridescent specular aluminum Optional lens available Reflector - Fluorescent Symmetric ■ ■ ■ 2000 SPI Lighting ■ 8 Up to 82% efficient Pre-finished, 85% reflective, low iridescent specular aluminum Optional lens available EXI 4403 120 BFT WL EXI 4811 120 BFT LENGTH FIXTURE ● 12” ● ● ● 19” ● ● ● 19” NUMBER ECI EDI EXI ● ECI EDI EXI ● EXI ● ● ● ● ● 50.5” 120 277 optional ● ● 120 277 optional ● BFT ● E435-3R E435-3R ● 120 277 optional ● BFT 4843 4853 4863 (1) 40 TT FL ‡ (1) 50 TT FL ‡ (1) 55 TT FL ‡ E435-23 E435-23 E435-23 ● 120 277 optional ● BFT 4813 8833 8843 8853 8863 (1) 32 T8 FL ‡ (2) 39 TT FL ‡ (2) 40 TT FL ‡ (2) 50 TT FL ‡ (2) 55 TT FL ‡ D435-24 ITT47421 ITT47421 ITT47421 ITT47421 ● 120 277 optional ● BFT ● 120 4873 (1) 59 T8 FL ‡ 277 optional 8813 (2) 32 T8 FL ‡ ‡ For FL symmetric fixture, change 4873 to 4871 To double number of FL lamps, add 2 to number: 48532 Lamps not supplied by factory; please consult Consult factory for T5 FL lamps, other wattages and photometrics ● BFT EXI ● ● ● ● ● ● ● (1) 70 T6 RSC MH (1) 150 T6 RSC MH ● ACCESSORIES pp. 18 - 20 CS - Cutoff shield, consult for FL WL CM - Ceiling mount +** ● PM - Pier mount +** ● SM - Stem mount ** Specify stem length: SM 24 * Consult factory for clusters ● HM - Hub mount ● HMSQ - Square hub mount ● WL - Wet location construction, EXI only ● F - Factory installed fuse † ● EM - Emergency lighting option, remote for 12” and 19” (FL) ** † ● FL - Acrylic lens (FL) ● BL - Blade louver (FL) ** ● DB - Dimming ballast (FL) ** † ● LP - Parabolic louver (FL) ** + Only for fixtures less than 27" ** Not available for WL fixture † Technical information, page 37 BFT 4203 4403 ECI EDI EXI EXI D435-20 FINISH E435-23 ● ● (1) 26 QUAD FL ‡ VOLTAGE (1) 27 TT FL ‡ (1) 39 TT FL ‡ ● 99” PHOTOMETRY 4823 4833 ● ● 26.5” 4803 LAMPING ● ● SAMPLE: ECI 4843 EDI 4803 120 BFT CS BFT 120 BFT CM PHOTOMETRICS 180˚ 180˚ 165˚ 90˚ 165˚ 200 135˚ 120˚ EXI 4813 120 BFT 6237 45˚ 0˚ 90˚ 1680 530 1060 1590 2120 45˚ 30˚ 0˚ 15˚ 51/4" WL Auxiliary Mounting Holes 57/16" 12" 511/16" 2" 17" 71/2" 6" 1260 60˚ ECI 4843 120 BFT DIMENSIONS 2" 15˚ 75˚ 840 105˚ 30˚ 800 90˚ 8316 120˚ 60˚ 600 420 135˚ 75˚ 400 105˚ 4158 90˚ 150˚ 150˚ 2079 D435-24 E435-23 D435-20 E435-3R 81/2" 12" / 19" 261/2" 501/2" 99" 24" 19" 261/2" 421/4" / 903/4" 501/2" 99" ■ 9 ECHO 2 ■ ECR / EDR / EXR - Remote Nine-inch diameter housings are available in standard solid or perforated metal and new extruded aluminum in two lengths. Lamping options range up to 400 watt metal halide or high pressure sodium, or a combination of the two. 8 Dual-lamped Echos provide uniform illumination free from glare and shadows, reducing eyestrain ECR 2403 120 BFT Housing Construction ■ ■ ■ ■ ■ ■ ■ ECR - perforated, 18 gauge roll formed steel EDR - solid, roll formed aluminum EXR - extruded .156 aluminum Die cast aluminum end caps with rotation stops Flush mounted fasteners UL Listed for US and Canada, damp location Decorative ShapesTM on pp. 24 - 27 Ballast Wet Location Construction - (WL) ECR / EDR / EXR - Remote ■ Magnetic, 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ Painted Finish ■ ■ ■ Mounting ■ ■ ■ ■ Yoke bracket die formed, 14 gauge steel Field adjustable housing Surface mount over a 4" box Cover plate conceals wiring and mounting hardware Reflector ■ ■ ■ ■ 2000 SPI Lighting ■ 10 Up to 80.7% efficient / asymmetric Maximum candlepower between 25° and 45° above horizontal Segmented, 95% reflective, specular clear hammertone aluminum Impact and heat resistant, tempered glass lens ■ ■ Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ ■ ■ ■ ■ ■ EXR - extruded aluminum housing only, UL Listed for US and Canada, wet location Die cast aluminum end caps with rotation stops Tamper-resistant fasteners Aluminum lens frame with gasketing Yoke bracket die formed, 14 gauge stainless steel Flexible weatherproof power cord with watertight fittings, black standard Consult factory for ground mount Remote ballast kit not wet location listed; consult factory MRI Construction - (MRI) ■ ■ ■ ECR / EDR - perforated or solid, roll formed aluminum housing Die cast aluminum end caps with rotation stops Yoke bracket die formed aluminum EDR 2403 120 BFT LENGTH FIXTURE ● 16” ● ● ECR EDR EXR NUMBER ● ● ● ● ● ● 16” 27.5” PHOTOMETRY VOLTAGE 2403 2503 2603 2053 2063 2743 (1) 175 ED17 Med MH (1) 250 ET18 Mogul MH (1) 400 ET18 Mogul MH (1) 250 E18 Mogul HPS (1) 400 E18 Mogul HPS ‡ (2) 250 T10 Med QTZ E436-8 E436-8 E436-8 E436-3R E436-3R ● FINISH 120 / 277 ● BFT ● 120 only ECR ● 2723 (1) 900 HIR T3 RSC QTZ E436-7 ● 240 or 277 ● BFT ● ECR EDR EXR ● 5503 5603 5653 5663 5723 (2) 250 ET18 Mogul MH (2) 400 ET18 Mogul MH 400 ET18 MH / 250 E18 HPS 400 ET18 MH / 400 E18 HPS ‡ (1) 900 HIR T3 RSC QTZ** E436-2R E436-2R E436-5R E436-5R ● 120 / 277 ● BFT ● 240 or 277 5733 5743 (2) 350 HIR T3 RSC QTZ (1) 1000 T6 RSC QTZ ● 120 only ● ● ● ● ● ● ECR ● ● ACCESSORIES pp. 18 - 20 CS - Cutoff shield, consult for WL CM - Ceiling mount ** ● PM - Pier mount ** ● DC - Double cluster ** ● TC - Triple cluster ** ● QC - Quad cluster ** ● SM - Stem mount ** * Specify stem length on cluster and stem mount fixtures: SM 24 ● HM - Hub mount ● HMSQ - Square hub mount ● WL - Wet location construction, EXR only † ● RPI - Remote ballast support tray ** † ● MRI - Non-magnetic fixture † ● F - Fuse option † ● Q - Stand-by lighting option, not available on 400W HID WL fixtures † ** Not available for WL fixture † Technical information, page 37 ● ● ● ● 27.5” LAMPING ‡ 400 HPS not available with standard encased and potted ballast; please see page 37 for additional information Indirect orientation only EDR 2603 120 BFT CS BFT SAMPLE: ECR 5503 120 BFT Q PHOTOMETRICS E436-8 180˚ E436-2R 180˚ 165˚ 180˚ 150˚ 150˚ 15000 E436-7 180˚ 165˚ 150˚ 135˚ 135˚ 105˚ 105˚ 105˚ 90˚ 22500 90˚ 67500 90˚ 90˚ 67500 45000 6875 13750 20625 27500 120˚ 120˚ 120˚ 105˚ 22500 165˚ 150˚ 135˚ 120˚ 120˚ 7500 180˚ 165˚ 150˚ 135˚ 135˚ E436-5R E436-3R 165˚ 22500 45000 105˚ 90˚ 3940 7880 11820 15760 ECR 5603 120 BFT DIMENSIONS WL 13" 81/4" 8" 2" Auxiliary Mounting Holes 2" 10" 11" 25" 271/2" 8" 133/4" 16" 16" 271/2" Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 175MH = 270’, 250MH = 190’, 400MH = 130’, 250 HPS = 10’, 400HPS = 50’. Consult factory for additional information. SIZE A B C 175 MH 3” 161/16” 33/16” 250 MH 3” 187/16” 33/16” 400 MH 3” 187/16” 33/16” 250 HPS 3” 2015/16” 33/16” 400 HPS Ballast Box Assembly ‡ C A B ■ 11 ECHO 2 ■ ECI / EDI / EXI - Integral Integral ballast makes for clean lines and easy installation. Nine-inch diameter housings are solid or perforated metal and extruded aluminum, in four standard lengths. Multiple lamping options include up to 400 watt metal halide or high pressure sodium and up to eight 55 watt compact or four 32 watt T8 linear fluorescent lamps. EXI 2503 120 BFT Housing Construction Reflector - Fluorescent Symmetric Painted Finish ECI - perforated, 18 gauge roll formed steel ■ EDI - solid, roll formed aluminum ■ EXI - extruded .156 aluminum ■ Die cast aluminum end caps with rotation stops ■ Flush mounted fasteners ■ UL Listed for US and Canada, damp location ■ Decorative ShapesTM on pp. 24 - 27 ■ Up to 82% efficient ■ Pre-finished, 85% reflective, low iridescent specular aluminum ‡ For FL symmetric fixture, change 5813 to 5811 ■ ■ Mounting Yoke bracket die formed, 14 gauge steel; two-piece for fixtures over 28” in length ■ Field adjustable housing ■ Surface mount over a 4” box ■ Cover plate conceals wiring and mounting hardware Ballast - HID EXI - Integral Magnetic, 120 volt operation; consult factory for other voltages ■ Open core and coil ■ CWA-HPF design ■ ■ ■ Reflector - HID Up to 78.9% efficient / asymmetric Maximum candlepower between 25° and 45° above horizontal ■ Segmented, 95% reflective, specular clear hammertone aluminum ■ Impact and heat resistant, tempered glass lens ■ Ballast - Fluorescent ECI / EDI / EXI - Integral Electronic, 120 volt operation / 277 volt optional ■ Class “A” sound rating and low harmonic distortion ■ Thermally protected ■ Minimum starting temperature 0° F ■ ■ ■ Ballast Notes 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ Reflector - Fluorescent Asymmetric ■ ■ 2000 SPI Lighting ■ 12 Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint ■ Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ Up to 65% efficient Pre-finished, 85% reflective, low iridescent specular aluminum EXI 6853 120 BFT Wet Location Construction - (WL) EXI - extruded aluminum housing only UL Listed for US and Canada, wet location ■ Die cast aluminum end caps with rotation stops ■ Aluminum lens frame with gasketing, MH ■ “Snap tight” acrylic lens, FL ■ Yoke bracket die formed, 14 gauge stainless steel; two-piece for fixtures over 28” in length ■ Flexible weatherproof power cord with watertight fittings, black standard ■ Consult factory for ground mount ■ LENGTH 16” FIXTURE ● ● ● 19” ● ● ● 27.5” ● NUMBER ECI EDI EXI ● ECI EDI EXI ● EXI ● ● 28032 • 28532 • 28632 ● ● ● ● 27.5” ● ● ● ECI EDI EXI ● ● ● ● 50.5” ● EXI ● ● ● ● ● 99” ● EXI ● ● ● ● ● SAMPLE: 2853 2863 ECI LAMPING PHOTOMETRY VOLTAGE 120 277 optional ● ● 120 277 optional ● BFT E436-8 E436-8 E436-8 E436-3R E436-3R ● 120 / 208 / 240 / 277 480 optional ● BFT E436-4 E436-4 E436-4 E436-4 ● 120 277 optional ● BFT (1) 32 TRIPLE FL ‡ (1) 42 TRIPLE FL ‡ ● (2) 26 TRIPLE FL (2) 32 TRIPLE FL (2) 42 TRIPLE FL ED17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS FINISH ACCESSORIES pp. 18 - 20 CS - Cutoff shield, consult for WL + CM - Ceiling mount, not available for MH and HPS; consult factory +** ● PM - Pier mount +** ● DC - Double cluster +** ● TC - Triple cluster +** ● QC - Quad cluster +** ● SM - Stem mount ** * Specify stem length on cluster and stem mount fixtures: SM 24 ● HM - Hub mount ● HMSQ - Square hub mount ● WL - Wet location construction, EXI only † ● MRI - Non-magnetic fixture † ● F - Factory installed fuse † ● EM - Emergency lighting option, remote for 16” (FL) † ● Q - Stand-by lighting option †, not available on 400W HID WL fixtures ● FL - Acrylic lens (FL) ** ● BL - Blade louver (FL) ** ● DB - Dimming ballast (FL) ** † ● LP - Parabolic louver ** + Not available for 99” fixtures ** Not available for WL fixture † Technical information on page 37 BFT ● ● 2403 2503 2603 2053 2063 175 250 400 250 400 5833 5843 5853 5863 (2) 39 TT FL ‡ (2) 40 TT FL ‡ (2) 50 TT FL ‡ (2) 55 TT FL ‡ 5813 6833 6843 6853 6863 (2) 32 T8 FL ‡ (4) 39 TT FL ‡ (4) 40 TT FL ‡ (4) 50 TT FL ‡ (4) 55 TT FL ‡ ● 120 277 optional ● BFT 5873 6813 7843 7853 7863 (2) 59 T8 FL ‡ (4) 32 T8 FL ‡ (8) 40 TT FL ‡ (8) 50 TT FL ‡ (8) 55 TT FL ‡ ● 120 277 optional ● BFT Consult factory for T5 FL lamps, other wattages and photometrics Lamps not supplied by factory; please consult 5853 120 BFT BL BFT PHOTOMETRICS E436-3R E436-8 180˚ 180˚ 165˚ E436-4 180˚ 165˚ 150˚ 120˚ 120˚ 15000 135˚ 135˚ 135˚ 7500 165˚ 150˚ 150˚ 120˚ 105˚ 105˚ 90˚ 22500 90˚ 6875 13750 20625 27500 105˚ 90˚ 950 1900 2850 3800 ECI 5853 120 BFT DIMENSIONS 13" WL 8" 2" Auxiliary Mounting Holes 81/4" 16" 2" 25" 10" 8" 13.75" 11" 16" 271/2" 501/2" 99" 271/2" EDI 2863 120 BFT CS BFT 421/4" / 903/4" 501/2" 99" ■ 13 ECHO 2 ■ ECT / EDT - Power Tray Solid or perforated metal fixtures are mounted in a one-piece ballast / yoke assembly. The Power Tray version has several contractor-friendly features for ease of installation and maintenance. Lamping options range up to 400 watt metal halide or high pressure sodium, or a combination of the two. 9 Echo provides glare-free illumination in this gymnasium ECT 2063 120 WH Housing Construction ■ ■ ■ ■ ■ ■ ■ ECT - perforated, 18 gauge roll formed steel EDT - solid, roll formed aluminum EXT - extruded, .156 aluminum Die cast aluminum end caps with rotation stops Flush mounted fasteners UL Listed for US and Canada, damp location Decorative Shapes on pp. 24 - 27 Ballast ECT / EDT - Power Tray Solid steel ballast housing ■ Open core and coil (encapsulated optional) ■ Prewired with quick-connect plugs ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ Painted Finish ■ Mounting ■ ■ ■ Yoke bracket / ballast housing die formed, 14 gauge steel Field adjustable housing Surface mount over a 4" box Reflector ■ ■ ■ ■ 2000 SPI Lighting ■ 14 Up to 80.7% efficient / asymmetric Maximum candlepower between 25° and 45° above horizontal Segmented, 95% reflective, specular clear hammertone aluminum Impact and heat resistant, tempered glass lens ■ ■ Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes LENGTH 16” PHOTOMETRY VOLTAGE 2403 2503 2603 2053 2063 (1) 175 (1) 250 (1) 400 (1) 250 (1) 400 E436-8 E436-8 E436-8 E436-3R E436-3R ● 5503 5603 5653 5663 (2) 250 ET18 Mogul MH (2) 400 ET18 Mogul MH 400 ET18 MH / 250 E18 HPS 400 ET18 MH / 400 E18 HPS E436-2R E436-2R E436-5R E436-5R ● NUMBER ● ECT EDT • EXT ● ● ● ● ● ● ● 27.5” LAMPING FIXTURE ● ECT EDT ● ● ● ● SAMPLE: ECT ED17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS 5603 FINISH 120 / 208 / 240 / 277 480 optional ● ACCESSORIES pp. 18 - 20 BFT CS - Cutoff shield F - Factory installed fuse † ● Q - Stand-by lighting option † † Technical information, page 37 ● ● 120 / 208 / 240 / 277 480 optional ● 120 BFT BFT Q PHOTOMETRICS E436-2R E436-8 180˚ 180˚ 165˚ 180˚ 120˚ 120˚ 7500 15000 150˚ 135˚ 120˚ 120˚ 105˚ 105˚ 105˚ 90˚ 22500 90˚ 67500 90˚ 22500 165˚ 135˚ 135˚ 135˚ 180˚ 165˚ 150˚ 150˚ 150˚ E436-5R E436-3R 165˚ 45000 6875 13750 20625 27500 105˚ 22500 45000 90˚ 67500 ECT 2503 120 WH DIMENSIONS 8" 8" 6" Auxiliary Mounting Holes 41/4" 3" 16" Power Tray 16" 21/2" 20" 271/2" 41/4" 21/2" 16" 271/2" 8" 273/4" Damp location ■ 15 ECHO 3 ■ ECR / EDR - Remote Housings are 16 1⁄2” in diameter, of solid or perforated steel. Lamping includes 400 or SPI’s unique 1000 watt metal halide and high pressure sodium, making it ideal for large spaces such as transportation and sports facilities. 10 Athletic training facility uses stem-mounted Echos single and double-clustered EDR 3803 277 WH SM60 and EDR DC 3803 277 WH SM60 ECR 3603 277 BFT Housing Construction Ballast Painted Finish ECR - perforated, 18 gauge roll formed steel ■ EDR - solid, 18 gauge roll formed steel ■ Die cast aluminum end caps ■ Flush mounted fasteners ■ UL Listed for US and Canada, damp location ■ ECR / EDR- Remote ■ Magnetic, multi-tap operation, 480 volt optional ■ Encased and potted ■ CWA-HPF design ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ Textured black (BFT) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint ■ Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ Mounting Yoke bracket die formed, 12 gauge steel Field adjustable housing ■ Surface mount ■ Cover plate conceals wiring and mounting hardware ■ ■ Reflector 76.8% efficient / asymmetric Maximum candlepower between 25° and 35° above horizontal ■ Segmented, 95% reflective, specular clear hammertone aluminum ■ Impact and heat resistant, tempered glass lens ■ ■ 2000 SPI Lighting ■ 16 EDR 3603 277 BFT FIXTURE LENGTH ● 23” ● ECR EDR NUMBER ● ● ● 3603 3803 3083 LAMPING PHOTOMETRY VOLTAGE (1) 400 BT37 MH (1) 1000 BT37 MH (1) 1000 BT37 HPS E437-1R E437-1R ● 120 / 208 / 240 / 277 480 optional FINISH CS - Cutoff shield PM - Pier mount ● DC - Double cluster ● SM - Stem mount * Specify stem length on cluster and stem mount fixtures: SM 60 ● F - Factory installed fuse † ● Q - Stand-by lighting option † † Technical information on page 37 ● BFT ● ACCESSORIES pp. 18 - 20 ● EDR 3603 277 BFT CS BFT SAMPLE: ECR 3803 277 BFT SM 60, Q PHOTOMETRICS E437-1R 180˚ 165˚ 150˚ 135˚ 120˚ 105˚ 19363 90˚ 38726 58088 77451 ECR 3603 277 BFT DIMENSIONS 143/4" 21/2" 8" 16" 18" Auxiliary Mounting Holes 23" 111/2" Standard Ballast Maximum Distance Lamp to Ballast with No. 12 Wire: 1000MH = 190’, 1000HPS = 50’ Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 400MH = 130’. SIZE A B C D 1000 MH 61/2” 167/16” 711/16” 185/8” 1000 HPS 53/4” 173/8” 711/16” 193/4” NOTE: Maximum dimensions are shown. 1000 watt ballast is not thermally protected. Allow 12” between ballasts in all directions when gang mounting to a common surface. Provide ventilation. Please consult factory for additional information. SIZE A B C 400 MH 3” 187/16” 33/16” NOTE: Please consult factory for additional information. C C A A B B D Damp location ■ 17 ECHO ■ Accessories Echo’s flexibility is achieved through its ability to be mounted and configured in a variety of methods. Please refer to pages 18 - 20 for detailed accessory information and page 21 for custom applications. DC ■ Pendant Clusters To specify standard pendant cluster fixtures, add DC, TC or QC to catalog number. Standard steel canopy painted to match housing. To specify open cluster bodies, add ODC, OTC or OQC to catalog number. (See drawings on page 19) EXAMPLE: EDR 3803 120 WH DC SIZE 1 DC 2-16” DC 2-271/2” DC 3 DC A 41/2” 8” 8” 143/4” B 16” 23” 23” 39” 1 TC 2-16” TC 2-271/2” TC 41/2” 8” 8” 22” DIA 33” DIA 45” DIA 1 QC 2-16” QC 2-271/2” QC 41/2” 8” 8” 231/2” DIA 36” DIA 471/2” DIA * A B * Consult factory for stem length B TC * Consult factory for Size 1.5 ■ Pier Mount - PM To specify splice compartment and cover plate for pier mounting, add PM to catalog number. EXAMPLE: EDR 2403 120 WH PM EDR 2403 120 WH PM ■ Stem Mount - SM To specify stem mount, add SM and stem length to catalog number. Size 1 and 1.5 use 1/8” IPS stem. Size 2 and 3 use 3/8” IPS stem. EXAMPLE: ECR 2603 120 BFT SM24 2000 SPI Lighting ■ 18 SIZE 1 1.5 2 3 A 41/2” 51/2” 8” 143/4” B 101/2” 12” 16” 231/4” C 113/4” 131/4” 17” 241/4” D 133/4” 151/4” 181/2” 26” ECR 2603 120 BFT SM24 ODC OTC OQC QC QC * A B * Consult factory for stem length B ■ Ceiling Mount - CM A To specify ceiling mount, add CM to catalog number. 356° horizontal adjustability. Consult factory for Size 2 Integral MH or HPS fixtures. EXAMPLE: EDR 2503 120 WH CM SIZE 1 1.5 2 A 8” 9” 101/2” B 51/8” 51/8” 51/8” EDR 2503 120 WH CM For standard fixture to be mounted on a horizontal or vertical surface in a cove, use the dimensions as noted below. SIZE 1 1.5 2 3 A 8” 9” 11” 22” B 4” 41/2” 53/8” 8” C 11” 13” 15” 30”” D 6” 57/16” 8” 14” A C D B C * B A D * Consult factory for stem length ■ 19 ECHO ■ Accessories ■ Hub Mount - HM B A HMSQ Hub mount accessory provides adjustability and allows for surface mounting with end canopies on a wall or ceiling. Use with ceiling mount fixtures greater than 271/2” long. Removable cover provides easy feed-through wiring. To specify hub mount, add HM or HMSQ (square end canopies) to the catalog number. EXAMPLE: EXI 4843 120 WH HM ■ Acrylic Lens - FL To specify acrylic lens (50% DR) for fluorescent fixtures, add FL to the catalog number. EXAMPLE: EXI 4853 120 BFT FL EXI 4853 120 WH FL EXI 4843 120 WH HM ■ Blade Louver - BL 1" To specify blade louver, add BL to the catalog number. Available for Size 1.5 and 2 fluorescent only. Louver painted White (WH) on White fixtures and Textured black (BFT) on Black. For other colors, please specify. Not available with Acrylic Lens (FL) option; consult for HID. EXAMPLE: EXI 4843 120 WH BL BFT 5/8" Louver Detail Fixture Housing EXI 4843 120 WH BL BFT ■ Cut-Off Shield - CS To specify cut-off shield, add CS to the catalog number. Not available with acrylic lens (FL). EXAMPLE: EDR 2403 120 BFT CS BFT A 2000 SPI Lighting ■ 20 EDR 2403 120 BFT CS BFT SIZE 1 1.5 2 3 A 73/4” 9” 123/8” 291/8” ■ Optional Mounting Mounting variations featured are Horizontal and Arch Stem Mounts, Continuous Row, and Beam Mount. Brackets may also be designed for special applications such as column or corner mounting. A C B ■ Continuous Row For continuous row applications, use the hub mount (HM or HMSQ) accessories. Consult the factory for special wiring and multiple lamp and ballast combinations. BB SIZE 1 1.5 2 A 8” 9” 11” B 2” 2” 2” C 2” 2” 2” ■ Cantilever Stem Mount To order Cantilever Stem Mount add “CL” to the catalog number. Example: ECR 2403 CL Available only with fixtures listed below. Maximum stem length wall to center of fixture without support cable: SIZE / LENGTH 1 / 10” 1.5 / 12” 1.5 / 12” 1.5 / 12” 2 / 16” FIXTURE ECR / EDR ECR / EDR / EXR ECI / EDI / EXI ECR / EDR / EXR ECR / EDR / EXR MAX. LENGTH 30” 24” 24” 24” 20” ■ Arch Stem Mount To order Beam Mount add “BM” to the catalog number. Example: EXI 4843 BM Available only with fixtures listed below. Maximum beam length wall to center of fixture: SIZE / LENGTH 1.5 / 12” 1.5 / 12” 1.5 / 19” 1.5 / 26-1/2” 2 / 16” 2 / 16” 2 / 27-1/2” 2 / 27-1/2” 3 / 23” FIXTURE ECR / EDR / EXR ECI / EDI / EXI ECI / EDI / EXI ECI / EDI / EXI ECR / EDR / EXR ECI / EDI / EXI ECR / EDR / EXR ECI / EDI / EXI ECR / EDR MAX. LENGTH 10-1/4” 10-1/4” 10-1/4” 10-1/4” 11-3/4” 11-3/4” 11-3/4” 11-3/4” 16” ■ 21 ECHO 1, 1.5 and 2 ■ ECR / EDR SR and ECI / EDI SR The semi-recessed wall wash series projects a controlled pattern of light to uniformly illuminate a wall from ceiling to floor. Echo’s adjustable fixture system eliminates scalloping, hot spots and striations while allowing the designer to paint luminous planes and enhance perimeter surfaces. 11 Echo projects an even wash of light across the wall, accenting the artwork ECR SR 1723 120 WH Housing Construction Reflector - Fluorescent Asymmetric Painted Finish ECR SR - perforated, 18 gauge roll formed steel ■ EDR SR - solid, 18 gauge roll formed steel (Size 1) or roll formed aluminum (Size 1.5 & 2) ■ Die cast aluminum end caps with rotation stops ■ Flush mounted fasteners ■ UL Listed for US and Canada, recessed non-IC, damp location ■ Up to 80% efficient ■ Pre-finished, 85% reflective, low iridescent specular aluminum ■ ■ Mounting Universal mounting brackets for 1/2" EMT, lathing channels or hanger brackets ■ Field adjustable housing ■ Yoke bracket die formed, 14 gauge steel ■ Reflector - HID / Quartz Up to 78.9% efficient / asymmetric Segmented, 95% reflective, specular clear hammertone aluminum ■ Impact and heat resistant, tempered, clear or textured glass lens ■ ■ 2000 SPI Lighting ■ 22 Ballast - HID ECR SR / EDR SR - Remote Magnetic 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ Other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ White (WH) Finish on recessed box and fixture to be the same ■ All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint ■ Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ Ballast - Fluorescent ECI SR / EDI SR - Integral Electronic, 120 volt operation / 277 volt optional ■ Class “A” sound rating and low harmonic distortion ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ EDR SR 1723 120 WH LENGTH FIXTURE ECR SR EDR SR ● 10.5” ● NUMBER ● ● ● ● ● 12” ● ● 19” ● ● 26.5” ● ● SAMPLE: (1) 70 RSC MH (1) 150 RSC MH (1) 150 T4 DC BAY QTZ (1) 300 T3 RSC QTZ D435-3R D435-3R D435-10R D435-10R ● 120 / 277 ● 120 ● ● WH 120 277 optional ● WH ● 120 277 optional ● WH D435-20 ECI SR EDI SR ● 4823 4833 (1) 27 TT FL (1) 39 TT FL D435-23 ECI SR EDI SR ● 4843 4853 4863 (1) 40 TT FL (1) 50 TT FL (1) 55 TT FL D435-23 D435-23 D435-23 ● 120 277 optional ● WH 2403 2503 2603 2053 2063 (1) 175 (1) 250 (1) 400 (1) 250 (1) 400 D436-8 D436-8 D436-8 D436-3R D436-3R ● 120 / 277 ● WH ● WH ● ● ● ● ● ECI SR EDI SR ● 1203 1403 1723 1733 (1) 26 QUAD FL ● ● FINISH 4803 ● 27.5” VOLTAGE ● ECR SR EDR SR ● PHOTOMETRY ECI SR EDI SR ● 16” LAMPING ECR SR E17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS‡ To double number of FL FL lamps, add 2 to number: 48532 ● 120 ● 5843 (2) 40 TT D436-4 ‡ 400 HPS not ● 5853 277 optional (2)available 50 TT FLwith standard encased D436-4and potted ballast; please 37TT for FL additional information ● 5863 see page (2) 55 D436-4 4853 120 PHOTOMETRICS 75˚ 4158 60˚ 6237 30˚ 8316 0˚ 45˚ 60˚ 60˚ 600 30˚ 0˚ D436-8 1060 400 60˚ 1590 45˚ 30˚ 800 15˚ 75˚ 75˚ 75˚ 3849 90˚ 530 200 1924 7699 15˚ D435-23 90˚ 90˚ 5774 45˚ BL WH D435-20 90˚ 2079 RPI - Remote ballast support tray (HID) † ● MRI - Non-magnetic fixture † ● F - Fuse option † ● Q - Stand-by lighting option, Size 2 only † ● EM - Emergency lighting option, remote for 12” (FL) † ● FL - Acrylic lens (FL) ● BL - Blade louver (FL) ● DB - Dimming ballast, (FL) ** † † Technical information, page 37 ● WH D435-10R D435-3R ACCESSORIES pp. 18 - 20 0˚ 45˚ 30˚ 2120 15˚ 0˚ 15˚ D436-3R 90˚ 75˚ 7500 60˚ 90˚ 6875 75˚ 13750 60˚ 15000 45˚ ECR SR 1723 120 WH 30˚ 22500 0˚ 15˚ 20625 45˚ 30˚ 27500 0˚ 15˚ DIMENSIONS A B C D SIZE 1 1.5 1.5 1.5 2 A 113/8” 121/2” 197/8” 27” 1619/32” B 511/16” 6” 6” 6” 951/64” C 53/32” 41/2” 41/2” 41/2” 6” D 31/2” 5” 5” 5” 6” Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 70MH = 20’, 150MH = 20’, 175MH = 270’, 250MH = 190’, 400MH = 130’, 250 HPS = 10’, 400HPS = 50’. Consult factory for additional information. SIZE 70 MH 150 MH 175 MH 250 MH 400 MH 250 HPS 400 HPS A B C 3” 133/8” 33/16” 3” 161/16” 33/16” 3” 161/16” 33/16” 3” 187/16” 33/16” 3” 187/16” 33/16” 3” 2015/16” 33/16” Ballast Box Assembly ‡ C A B Damp location ■ 23 SHAPESTM 1 and 2 ■ EBR / EER / EGR - Remote Echo Shapes are available in two sizes and three housing styles; Scroll, Scoop and Wedge. Lamping options range up to 400 watt metal halide or high pressure sodium and up to 350 watt quartz-halogen. TM 12 Size 2 Scoops compliment the architectural lines of this hallway EBR 2503 120 WH EER 2503 120 WH Housing Construction Ballast MRI Construction - (MRI) EBR - Scroll ■ EER - Scoop ■ EGR - Wedge ■ Die-formed 18 gauge steel ■ UL Listed for US and Canada, damp location Remote ■ Magnetic 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ Mounting ■ ■ EBR / EER / EGR - formed aluminum housing ■ Not available for cluster or stem mounted fixtures Surface mount over a 4" box Painted Finish White (WH) Finish on internal housing and Shape to be the same ■ All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint ■ Consult Powder Coat Color Finishes catalog page for additional standard painted finishes Reflector ■ Up to 78.9% efficient / asymmetric ■ Maximum candlepower between 25° and 45° above horizontal ■ Segmented, 95% reflective, specular clear hammertone aluminum ■ Field adjustable ■ Impact and heat resistant, tempered, clear or textured glass lens ■ ■ 2000 SPI Lighting ■ 24 EGR 2503 120 WH LENGTH FIXTURE ● 10.5” ● ● EBR EER EGR NUMBER ● ● ● ● ● ● 16” ● ● EBR EER EGR ● ● ● ● ● LAMPING PHOTOMETRY 1203 1403 1723 1733 1743 (1) 70 T6 RSC MH (1) 150 T6 RSC MH (1) 150 T4 DC BAY QTZ (1) 300 T3 RSC QTZ (1) 350 HIR T3 RSC QTZ 2403 2503 2603 2053 2063 (1) 175 (1) 250 (1) 400 (1) 250 (1) 400 VOLTAGE ● 120 / 277 FINISH ● WH ACCESSORIES pp. 18 - 20 DC - Double cluster * TC - Triple cluster * ● QC - Quad cluster * * Specify stem length on cluster fixtures: SAB 60 ● RPI - Remote ballast support tray ** † ● MRI - Non-magnetic fixture † ● F - Fuse option † ● Q - Stand-by lighting option, Size 2 only † † Technical information, page 37 ● ● ● 120 only ● 120 / 277 ● WH ED17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS ‡ ‡ 400 HPS not available with standard encased and potted ballast; please see page 37 for additional information SAMPLE: EBR 2503 120 WH Q PHOTOMETRICS - Consult factory for test data optical: 2503 120 WH DIMENSIONS EER EBR Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 70MH = 20’, 150MH = 20’, 175MH = 270’, 250MH = 190’, 400MH = 130’, 250 HPS = 10’, 400HPS = 50’. Consult factory for additional information. EGR C D A SIZE 1 2 B E A 10” 15” B 103/4” 16” C 5” 8” D 21/4” 21/4” E 53/8” 8” SIZE 70 MH 150 MH 175 MH 250 MH 400 MH 250 HPS 400 HPS A B C 3” 133/8” 33/16” 3” 161/16” 33/16” 3” 161/16” 33/16” 3” 187/16” 33/16” 3” 187/16” 33/16” 3” 2015/16” 33/16” Ballast Box Assembly ‡ C A B Damp location ■ 25 SHAPESTM 1 and 2 ■ EET / EGT - Integral Where remote ballasting isn’t suitable, the Power Tray version offers flexibility: three sizes, two housing styles — Scoop and Wedge — and fluorescent, metal halide or high pressure sodium lamping. TM 13 This hospital cafeteria uses Echos to softly illuminate skylights at night EET 2503 120 WH Housing Construction Reflector Painted Finish EET - Scoop ■ EGT - Wedge ■ Die-formed 18 gauge steel ■ UL Listed for US and Canada, damp location ■ Up to 78.9% efficient / asymmetric ■ Maximum candlepower between 25° and 45° above horizontal ■ Segmented, 95% reflective specular clear hammertone aluminum ■ Field adjustable ■ Impact and heat resistant, tempered, clear or textured glass lens ■ ■ Mounting ■ Surface mount over a 4" box White (WH) Finish on internal housing and Shape to be the same ■ All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint ■ Consult Powder Coat Color Finishes catalog page for additional standard painted finishes ■ Ballast Power Tray compartment Magnetic, multi-tap operation, 480 volt optional ■ Open core & coil, encapsulated optional ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ 2000 SPI Lighting ■ 26 EGT 2503 120 WH LENGTH FIXTURE ● 14.5” ● ● 16” ● NUMBER EET EGT ● EET EGT ● ● ● ● ● ● SAMPLE: EGT PHOTOMETRY LAMPING VOLTAGE 1203 1403 (1) 70 T6 RSC MH (1) 150 T6 RSC MH ● 2403 2503 2603 2053 2063 (1) 175 (1) 250 (1) 400 (1) 250 (1) 400 ● ED17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS 2503 120 / 208 240 / 277 480 optional 120 / 208 240 / 277 480 optional 120 FINISH ● WH ACCESSORIES pp. 18 - 20 F - Fuse option † Q - Stand-by lighting option (Size 2 MH) † † Technical information, page 37 ● ● ● WH WH F PHOTOMETRICS - Consult factory for test data EGT 2503 120 WH DIMENSIONS EET 8" EGT Power Tray 21/2" / 4" C D 101/2" / 16" Auxiliary Mounting Holes A SIZE 1 2 B A 16” 21” B C 141/2” 6” 16” 8” D 3” 4” E 71/4” 8” E Damp location ■ 27 COVE MOUNT 1 and 2 ■ ECM Specifically designed for cove illumination, the ECM’s simple design disappears behind architectural elements. Three sizes and multiple lamping options make it suitable for a variety of applications. ECM 2503 120 WH and ECM 1403 120 WH Housing Construction ■ ■ ■ ■ ECM - 20 gauge die formed steel Prewired, 1/2” O.D. flexible metal conduit, 18” long Insulated wire leads extend 6” beyond cable end UL Listed for US and Canada, damp location Ballast - HID Painted Finish Remote ■ Magnetic, 120 / 277 volt operation ■ Encased and potted ■ CWA-HPF design ■ Thermally protected ■ 347 and other voltages / frequencies available for international market † † Additional information on page 37 ■ ■ ■ ■ Textured white (WH) All metal surfaces first thoroughly cleaned and coated with thermoset polyester paint Consult Powder Coat Color Finishes catalog page for additional standard painted finishes Mounting ■ ■ Mount to horizontal or vertical surfaces Two sets of adjustable brackets Ballast - Fluorescent ■ ■ Reflector - HID / Quartz ■ ■ ■ ■ Up to 78.9% efficient / asymmetric Segmented, 95% reflective, specular clear hammertone aluminum Field adjustable Impact and heat resistant, tempered, hinged, clear or textured glass lens ■ ■ Integral Electronic,120 volt operation / 277 volt optional Class “A” sound rating and low harmonic distortion Thermally protected Reflector - Fluorescent ■ ■ ■ 2000 SPI Lighting ■ 28 Up to 85% efficient Pre-finished, 85% reflective, low iridescent specular aluminum Optional lens available ECM 2503 120 WH FIXTURE LENGTH ● 10.5” ECM ● ● ● ● ● 26.5” ● ECM ● ● ● 50.5” ● ECM ● ● ● ● ● 16” ● ECM LAMPING PHOTOMETRY VOLTAGE 1203 1403 1723 1733 1743 (1) 70 T6 RSC MH (1) 150 T6 RSC MH (1) 150 T4 DC BAY QTZ (1) 300 T3 RSC QTZ (1) 350 HIR T3 RSC QTZ E435-3R E435-3R E435-10R E435-10R E435-10R ● 4843 4853 4863 (1) 40 TT FL ◆ (1) 50 TT FL ◆ (1) 55 TT FL ◆ E435-23 E435-23 E435-23 ● 120 277 optional ● WH 4813 8833 8843 8853 8863 (1) 32 T8 FL (2) 39 TT FL ◆ (2) 40 TT FL ◆ (2) 50 TT FL ◆ (2) 55 TT FL ◆ E435-24 ITT47421 ITT47421 ITT47421 ITT47421 ● 120 277 optional ● WH ● WH NUMBER ● ● ● ● ● ◆ 2403 2503 2603 2053 2063 (1) 175 (1) 250 (1) 400 (1) 250 (1) 400 ED17 Med MH ET18 Mogul MH ET18 Mogul MH E18 Mogul HPS E18 Mogul HPS ‡ FINISH 120 / 277 ● ACCESSORIES pp. 18 - 20 F - Fuse option † Q - Stand-by lighting option, Size 2 only † ● EM - Emergency lighting option (FL) ● DB - Dimming ballast (FL) † ● FL - Acrylic lens (FL) † † Technical information, page 37 WH ● ● ● E436-8 E436-8 E436-8 E436-3R E436-3R ● 120 only 120 / 277 To double number of FL lamps, add 2 to number: 48532 ‡ 400 HPS not available with standard encased and potted ballast. Please see page 37 for additional information. SAMPLE: ECM 1403 120 WH F PHOTOMETRICS E435-3R 180˚ 165˚ E435-10R E435-24 E436-8 E436-3R 180˚ 180˚ 180˚ 180˚ 165˚ 6237 135˚ 90˚ 8316 1924 3849 5774 90˚ 7699 150˚ 840 1260 90˚ 1680 120˚ 120˚ 105˚ 420 135˚ 135˚ 120˚ 105˚ 105˚ 165˚ 150˚ 120˚ 120˚ 4158 165˚ 150˚ 135˚ 135˚ 2079 165˚ 150˚ 150˚ 105˚ 105˚ 7500 15000 90˚ 22500 90˚ 6875 13750 20625 27500 ECM 1403 120 WH DIMENSIONS Standard Remote Ballast Kit Maximum Distance Lamp to Ballast with No. 12 Wire: 70MH = 20’, 150MH = 20’, 175MH = 270’, 250MH = 190’, 400MH = 130’, 250 HPS = 10’, 400HPS = 50’. Consult factory for additional information. A 4" 71/8" 15/8" 21/2" C F D 4" SIZE 1 1 1 2 A 41/2” 71/2” 71/2” 81/2” B 101/4” 253/4” 493/4” 15” SIZE 1 FL C 4” 45/16” 45/16” 71/8” D 4” 4” 4” 4” E 9” 241/2” 481/2” 133/4” F 15/8” 31/2” 31/2” 21/2” SIZE 70 MH 150 MH 175 MH 250 MH 400 MH 250 HPS 400 HPS A B C 3” 133/8” 33/16” 3” 161/16” 33/16” 3” 161/16” 33/16” 3” 187/16” 33/16” 3” 187/16” 33/16” 3” 2015/16” 33/16” Ballast Box Assembly ‡ C A B Damp location ■ 29 ECHO 1 and 1.5 ■ Photometrics 25 25 25 180˚ 165˚ 150˚ 180˚ 165˚ 150˚ 135˚ 90˚ 135˚ 8316 7699 200 120˚ 6237 75˚ 120˚ 5774 400 4158 3849 105˚ 60˚ 105˚ 2079 600 1924 90˚ 90˚ 800 45˚ 0˚ LEGEND: 0-deg. 45-deg. 90-deg. Test Number ■ E435-3R / ITL48932 Fixture ■ Size 1 and 1.5 RSC MH Optical ■ Forward throw distribution ■ Premium hammertone metal reflector ■ Textured (pattern 62) flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 150 watt MH-double ended, horizontal position ■ Rated 13,500 lumens Ballasts ■ One magnetic Test Number ■ E435-10R / ITL49271 Fixture ■ Size 1 and 1.5 Quartz Optical ■ Forward throw distribution ■ Premium hammertone metal reflector ■ Textured (pattern 62) flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 350 HIR T3 CL RSC Quartz, horizontal position ■ Rated 10,000 lumens ZONAL LUMEN SUMMARY Zone Lumens % Lamp 0 0 0 54 3312 5487 8836 9997 10051 0.0 0.0 0.0 0.4 24.5 40.6 64.0 74.1 74.5 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 WATT / TYPE LUMENS (1) 150 HQI (1) 70 MH-DE (1) 70 HQI 12,000 6,000 5,500 RC RW 0 1 2 3 4 5 6 7 8 9 10 Zone 0.0 0.0 0.0 0.5 33.0 54.6 85.9 99.5 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 70 71 64 59 53 49 44 41 38 35 32 30 Lumens % Lamp ZONAL LUMEN SUMMARY 0 0 0 21 1783 3548 5695 6607 6628 0.0 0.0 0.0 0.2 17.8 35.5 56.9 66.1 66.3 % Fixt. Zone 0.0 0.0 0.0 0.3 26.9 53.5 85.9 99.7 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 PRORATION FACTOR .89 .44 .41 LUMENS (1) 300 T3 RSC Q (1) 150 T4 DC BAY Q 5,750 2,700 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 71 56 46 38 32 27 23 20 17 15 13 70 61 55 50 45 41 38 35 32 29 27 25 10 61 48 40 33 28 23 20 17 15 13 12 50 42 36 31 28 24 22 19 17 16 14 13 50 30 42 35 29 25 22 19 16 14 13 11 10 10 42 34 28 23 19 17 14 12 11 9 8 50 24 21 18 16 14 13 11 10 9 8 8 30 30 24 20 17 15 13 11 10 9 8 7 6 10 50 24 8 20 7 16 6 14 5 12 5 10 4 8 4 7 3 6 3 6 3 5 2 10 30 8 7 6 5 4 4 3 3 2 2 2 10 8 6 5 4 4 3 3 2 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 63 57 52 48 43 40 36 33 31 29 27 80 50 30 63 63 55 52 48 44 42 37 37 32 33 28 29 24 26 21 23 19 21 17 19 15 10 63 50 41 34 28 24 21 18 15 14 12 70 54 49 44 40 37 34 31 28 26 24 23 70 50 30 54 54 47 45 41 38 36 32 32 28 28 24 25 21 22 18 20 16 18 14 17 13 10 54 43 35 29 25 21 18 15 13 12 10 50 37 32 28 25 22 19 17 15 14 13 11 50 30 37 31 26 22 19 17 15 13 11 10 9 10 37 30 25 21 17 15 13 11 10 8 7 50 21 18 16 14 13 11 10 9 8 7 7 30 30 21 18 15 13 11 10 9 8 7 6 5 10 50 21 7 17 6 14 5 12 5 10 4 9 4 8 3 7 3 6 3 5 2 4 2 The following indirect fixtures were tested in accordance with IES recommendations for laboratory tests by independant testing laboratories 2000 SPI Lighting ■ 30 % Lamp 233 410 850 1257 62 63 63 63 1320 12.9 22.8 47.2 69.8 3.4 3.5 3.5 3.5 73.3 % Fixt. 17.7 31.1 64.4 95.2 4.7 4.8 4.8 4.8 100.0 PRORATION FACTOR .58 .27 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 70 50 30 61 61 53 50 46 42 40 36 35 31 31 27 28 23 25 21 23 18 20 16 19 14 Lumens TOTAL LUMINAIRE EFFICIENCY = 73.3% TOTAL LUMINAIRE EFFICIENCY = 66.3% WATT / TYPE COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD 80 50 30 71 71 61 59 54 49 47 42 41 36 37 31 33 27 29 24 26 21 24 19 22 17 Test Number ■ D435-20 / BALL9070.0 Fixture ■ Size 1.5 Quad FL Optical ■ Forward throw distribution ■ Fabricated low iridescent specular metal reflector ■ Fixture tilted 25 degrees beyond vertical Lamps ■ (1) 26 watt Quad Fluorescent, horizontal position ■ Rated 1,800 lumens Ballasts ■ One electronic ZONAL LUMEN SUMMARY % Fixt. TOTAL LUMINAIRE EFFICIENCY = 74.5% 30˚ 15˚ LEGEND: 0-deg. 45-deg. 90-deg. LEGEND: 0-deg. 45-deg. 90-deg. COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 30 7 6 5 4 4 3 3 2 2 2 2 10 7 6 5 4 3 3 2 2 2 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 86 78 70 64 59 54 50 46 43 40 37 80 50 30 86 86 74 70 64 59 56 50 50 43 44 38 40 33 36 29 32 26 30 23 27 21 10 86 67 54 45 38 33 28 25 22 19 17 70 84 75 68 62 57 52 48 44 41 38 36 70 50 30 84 84 71 68 62 57 55 49 48 42 43 37 39 33 35 29 32 26 29 23 27 21 10 84 65 53 44 37 32 28 24 22 19 17 50 80 68 59 52 46 41 37 34 31 28 26 50 30 80 65 55 47 41 36 32 28 25 23 20 10 80 62 51 43 37 31 27 24 21 19 17 50 75 64 56 49 44 39 36 32 29 27 25 30 30 75 62 53 45 39 35 31 27 24 22 20 10 75 60 50 42 36 31 27 24 21 19 17 50 72 61 53 47 42 38 34 31 28 26 24 10 30 72 59 50 44 38 34 30 27 24 21 19 10 72 57 48 41 35 30 26 23 20 18 16 0 0 70 56 46 39 33 28 25 22 19 17 15 ECHO 1.5 and 2 ■ Photometrics 25 25 25 180˚ 165˚ 150˚ 180˚ 22500 135˚ 165˚ 150˚ 135˚ 90˚ 2120 15000 420 120˚ 1590 75˚ 120˚ 840 1060 7500 60˚ 105˚ 105˚ 1260 530 90˚ 90˚ 1680 45˚ 0˚ LEGEND: 0-deg. 45-deg. 90-deg. LEGEND: 0-deg. 45-deg. 90-deg. LEGEND: 0-deg. 45-deg. 90-deg. Test Number ■ E435-23 / BALL8907.0 Fixture ■ Size 1.5 TT FL Optical ■ Forward throw distribution ■ Fabricated low iridescent specular metal reflector ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 55 watt TT fluorescent, horizontal position ■ Rated 4,800 lumens Ballasts ■ One electronic Test Number ■ D435-24 / BALL8525.0 Fixture ■ Size 1.5 T8 FL Optical ■ Forward throw distribution ■ Fabricated low iridescent specular metal reflector ■ Fixture tilted 25 degrees beyond vertical Lamps ■ (1) 32 watt T8 linear fluorescent, horizontal position ■ Rated 2,850 lumens Ballasts ■ One electronic ZONAL LUMEN SUMMARY Zone Lumens % Lamp 0 0 0 86 1451 2096 3200 3764 3851 0.0 0.0 0.0 1.8 30.2 43.7 66.7 78.4 80.2 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 % Fixt. Zone 0.0 0.0 0.0 2.2 37.7 54.4 83.1 97.8 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 LUMENS (1) 50 TT FL (1) 40 TT FL (1) 39 TT FL 4,000 3,150 2,850 70 77 69 63 57 52 48 44 41 38 35 33 Lumens % Lamp ZONAL LUMEN SUMMARY 532 934 1829 2408 20 20 20 20 2428 18.7 32.8 64.2 84.5 .7 .7 .7 .7 85.2 % Fixt. Zone 21.9 38.4 75.3 99.2 .8 .8 .8 .8 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 PRORATION FACTOR .83 .66 .59 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 77 60 48 40 34 29 25 22 19 17 15 70 66 59 54 49 44 41 37 35 32 30 28 70 50 30 66 66 56 54 49 45 43 38 38 33 34 29 30 25 27 22 25 20 22 18 21 16 10 66 51 42 35 29 25 22 19 17 15 13 50 46 39 34 30 26 23 21 19 17 16 14 50 30 46 37 31 27 23 20 18 16 14 13 11 10 46 36 29 24 21 18 15 13 12 10 9 50 27 23 20 17 15 14 12 11 10 9 9 30 30 27 22 18 16 14 12 10 9 8 8 7 10 27 21 17 14 12 10 9 8 7 6 6 10 50 30 10 10 8 7 7 6 6 5 5 5 5 4 4 4 4 3 3 3 3 3 3 2 10 10 7 6 5 4 3 3 3 2 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 99 92 84 77 70 64 58 53 49 45 41 80 50 30 99 99 88 85 77 71 68 61 60 52 52 44 46 39 41 34 37 29 33 25 29 22 10 99 81 66 55 46 39 33 28 24 20 18 70 99 90 82 75 68 62 56 52 47 43 40 70 50 30 99 99 86 83 75 70 66 60 59 51 51 44 46 38 41 33 36 29 32 25 29 22 10 99 80 65 55 46 38 33 28 24 20 18 50 94 83 72 64 56 49 44 39 35 31 28 50 30 94 80 68 58 50 43 37 32 28 24 22 10 94 77 64 54 45 38 32 28 24 20 17 Lumens % Lamp 0 0 0 238 10484 14860 22190 25805 26042 0.0 0.0 0.0 0.7 31.8 45.0 67.2 78.2 78.9 % Fixt. 0.0 0.0 0.0 0.9 40.3 57.1 85.2 99.1 100.0 TOTAL LUMINAIRE EFFICIENCY = 78.9% TOTAL LUMINAIRE EFFICIENCY = 85.2% TOTAL LUMINAIRE EFFICIENCY = 80.2% 80 50 30 77 77 66 62 57 52 50 44 44 38 39 33 35 29 32 26 29 23 26 21 24 19 Test Number ■ E436-8 / ITL50199 Fixture ■ Size 2 MH Optical ■ Forward throw distribution ■ Premium hammertone metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 400 watt ET18 clear metal halide ■ Rated 33,000 lumens, horizontal position Ballasts ■ One magnetic ZONAL LUMEN SUMMARY WATT / TYPE RC RW 0 1 2 3 4 5 6 7 8 9 10 30˚ 15˚ 50 90 79 69 61 54 48 42 38 34 30 27 30 30 90 77 66 57 49 42 36 32 28 24 21 10 90 75 62 53 45 37 32 27 23 20 17 50 86 76 67 59 52 46 41 37 33 29 26 WATT / TYPE LUMENS (1) 250 E18 MH (1) 175 E17 MH 22,000 13,500 PRORATION FACTOR .67 .41 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 30 86 74 64 55 48 41 36 31 27 24 21 10 86 72 61 52 44 37 32 27 23 20 17 0 0 85 71 59 50 42 35 30 25 21 18 16 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 75 68 62 57 52 47 43 40 37 34 32 80 50 30 75 75 65 62 57 52 50 44 44 38 39 33 34 29 31 25 28 22 25 20 23 18 10 75 59 48 40 34 28 24 21 18 16 14 70 64 58 53 48 44 40 37 34 31 29 27 70 50 30 64 64 56 53 49 45 43 38 38 33 33 28 30 25 27 22 24 19 22 17 20 15 10 64 51 42 35 29 25 21 18 16 14 12 50 44 38 33 29 26 23 20 18 17 15 14 50 30 44 37 31 27 23 20 17 15 14 12 11 10 44 35 29 24 21 17 15 13 11 10 9 50 26 22 19 17 15 13 12 11 10 9 8 30 30 26 21 18 16 13 12 10 9 8 7 6 10 50 26 9 21 7 17 6 14 6 12 5 10 4 9 4 8 4 7 3 6 3 5 3 10 30 9 7 6 5 4 4 3 3 3 2 2 10 9 7 6 5 4 3 3 3 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 The above indirect fixtures were tested in accordance with IES recommendations for laboratory tests by Independent Testing Laboratories ■ 31 ECHO 2 Photometrics 25 25 180˚ 165˚ 180˚ 150˚ 25 165˚ 150˚ 180˚ 120˚ 15760 120˚ 2850 7880 105˚ 105˚ 3940 90˚ 90˚ LEGEND: 0-deg. 45-deg. 90-deg. ZONAL LUMEN SUMMARY % Lamp 0 0 0 397 16294 23102 34497 40139 40536 0.0 0.0 0.0 0.8 31.9 45.3 67.6 78.7 79.5 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 ZONAL LUMEN SUMMARY % Fixt. Zone 0.0 0.0 0.0 1.0 40.1 57.0 85.1 99.1 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 TOTAL LUMINAIRE EFFICIENCY = 79.5% WATT / TYPE LUMENS (1) 250 E18 HPS 28,000 Lumens % Lamp 0 0 0 88 2292 3433 5337 6150 6238 0.0 0.0 0.0 0.9 23.9 35.8 55.6 64.1 65.0 ZONAL LUMEN SUMMARY % Fixt. Zone 0.0 0.0 0.0 1.4 36.7 55.0 85.6 98.6 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 TOTAL LUMINAIRE EFFICIENCY = 65% PRORATION FACTOR .55 WATT / TYPE LUMENS (2) 50 TT FL (2) 40 TT FL (2) 39 TT FL 8,000 6,300 5,700 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 76 60 49 40 34 29 25 21 18 16 14 70 65 59 53 48 44 40 37 34 31 29 27 70 50 30 65 65 56 54 49 45 43 39 38 33 34 29 30 25 27 22 24 19 22 17 20 15 10 65 52 42 35 29 25 21 18 16 14 12 50 45 38 34 29 26 23 21 19 17 15 14 50 30 45 37 31 27 23 20 17 15 14 12 11 10 45 36 29 25 21 18 15 13 11 10 9 50 26 22 19 17 15 13 12 11 10 9 8 30 30 26 22 18 16 14 12 10 9 8 7 6 10 50 26 9 21 7 17 6 14 6 12 5 10 4 9 4 8 4 7 3 6 3 5 3 10 30 9 7 6 5 4 4 3 3 3 2 2 10 9 7 6 5 4 3 3 3 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 62 56 51 46 42 39 36 33 30 28 26 80 50 30 62 62 53 51 47 43 41 36 36 31 32 27 28 23 25 21 23 18 21 16 19 14 10 62 49 40 33 28 23 20 17 15 13 12 70 53 48 44 40 36 33 30 28 26 24 22 70 50 30 53 53 46 44 40 37 35 31 31 27 27 23 24 20 22 18 20 16 18 14 16 13 10 53 42 34 28 24 20 17 15 13 11 10 50 37 31 27 24 21 19 17 15 14 12 11 50 30 37 30 26 22 19 16 14 13 11 10 9 10 37 29 24 20 17 14 12 11 9 8 7 50 21 18 16 14 12 11 10 9 8 7 7 30 30 21 18 15 13 11 10 8 7 7 6 5 The following indirect fixtures were tested in accordance with IES recommendations for laboratory tests by independant testing laboratories 2000 SPI Lighting ■ 32 Lumens % Lamp 0 0 0 197 8701 13382 19434 21952 22150 0.0 0.0 0.0 0.6 27.2 41.8 60.7 68.6 69.2 % Fixt. 0.0 0.0 0.0 0.9 39.3 60.4 87.7 99.1 100.0 TOTAL LUMINAIRE EFFICIENCY = 69.2% PRORATION FACTOR .83 .66 .59 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD 80 50 30 76 76 65 63 57 53 50 45 44 38 39 33 35 29 31 25 28 22 25 20 23 18 Test Number ■ E436-7 / ITL45917 Fixture ■ Size 2 Quartz Optical ■ Forward throw distribution ■ Fabricated hammertone metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 900 HIR T3 CL RSC Quartz, horizontal position ■ Rated 32,000 lumens ■ 240 or 277 volt operation only Test Number ■ E436-4 / ITL45918 Fixture ■ Size 2 TT FL Optical ■ Forward throw distribution ■ Fabricated low iridescent specular metal reflector ■ Fixture tilted 25 degrees below horizontal Lamps ■ (2) 55 watt TT fluorescent, horizontal position ■ Rated 4,800 lumens each Ballasts ■ One electronic Test Number ■ E436-3R / ITL50199 Fixture ■ Size 2 HPS Optical ■ Forward throw distribution ■ Premium hammertone metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 400 watt E18 CL HPS, horizontal position ■ Rated 51,000 lumens Ballasts ■ One magnetic 70 76 69 63 57 52 47 44 40 37 34 32 90˚ LEGEND: 0-deg. 45-deg. 90-deg. LEGEND: 0-deg. 45-deg. 90-deg. RC RW 0 1 2 3 4 5 6 7 8 9 10 105˚ 950 6875 Lumens 120˚ 11820 1900 13750 Zone 150˚ 135˚ 3800 20625 165˚ 135˚ 135˚ 27500 10 50 21 7 17 6 14 5 12 5 10 4 9 4 7 3 6 3 6 3 5 2 4 2 WATT / TYPE LUMENS (1) 1000 T6 QTZ 23,400 PRORATION FACTOR .73 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 30 7 6 5 4 4 3 3 2 2 2 2 10 7 6 5 4 3 3 2 2 2 2 1 0 0 1 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 66 60 54 50 45 41 38 35 32 30 28 80 50 30 66 66 57 54 50 46 44 39 38 33 34 29 30 25 27 22 24 19 22 17 20 15 10 66 52 42 35 30 25 21 18 16 14 12 70 57 51 46 42 38 35 32 30 27 25 24 70 50 30 57 57 49 47 43 39 37 34 33 29 29 25 26 22 23 19 21 17 19 15 17 13 10 57 45 37 31 26 22 19 16 14 12 11 50 39 33 29 26 23 20 18 16 15 13 12 50 30 39 32 27 23 20 17 15 13 12 11 9 10 39 31 26 21 18 15 13 11 10 9 8 50 23 19 17 15 13 12 10 9 8 8 7 30 30 23 19 16 14 12 10 9 8 7 6 6 10 50 23 8 18 6 15 6 13 5 11 4 9 4 8 3 7 3 6 3 5 3 5 2 10 30 8 6 5 4 4 3 3 3 2 2 2 10 8 6 5 4 4 3 3 2 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 ECHO 2 Dual and 3 ■ Photometrics 25 180˚ 49500 25 165˚ 180˚ 67500 150˚ 25 165˚ 150˚ 180˚ 165˚ 150˚ 135˚ 135˚ 135˚ 77451 45000 33000 120˚ 120˚ 16500 38726 22500 105˚ 120˚ 53088 105˚ 105˚ 19363 90˚ 90˚ LEGEND: 0-deg. 45-deg. 90-deg. LEGEND: 0-deg. 45-deg. 90-deg. Test Number ■ E436-2R / ITL49452 Fixture ■ Size 2 Dual Metal Halide Optical ■ Forward throw distribution ■ Fabricated peened metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (2) 400 watt ET18 clear metal halide ■ Rated 33,000 lumens each, horizontal position Ballasts ■ Two magnetic LEGEND: 0-deg. 45-deg. 90-deg. Test Number ■ E436-5R / ITL49453 Fixture ■ Size 2 Dual HPS / MH Optical ■ Forward throw distribution ■ Fabricated peened metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 400 watt ET18 clear metal halide / (1) 400-watt E18 clear high pressure sodium ■ Rated 33,000 lumens (MH) / 51,000 lumens (HPS), horizontal position Ballasts ■ Two magnetic ZONAL LUMEN SUMMARY Zone Lumens % Lamp 0 0 0 440 20567 30521 45472 52822 53262 0.0 0.0 0.0 0.5 31.2 46.2 68.9 80.0 80.7 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 WATT / TYPE LUMENS 400 MH / 250 MH 250 MH / 250 MH 53,000 40,000 Zone 0.0 0.0 0.0 0.8 38.6 57.3 85.4 99.2 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 70 77 70 63 58 53 48 44 41 38 35 32 Lumens % Lamp 0 0 0 307 26605 38872 57406 66328 66635 0.0 0.0 0.0 0.4 31.7 46.3 68.3 78.9 79.3 ZONAL LUMEN SUMMARY % Fixt. Zone 0.0 0.0 0.0 0.5 39.9 58.3 86.1 99.5 100.0 0 - 30 0 - 40 0 - 60 0 - 90 90 - 120 90 - 130 90 - 150 90 - 180 0 - 180 TOTAL LUMINAIRE EFFICIENCY = 79.3% PRORATION FACTOR .80 .61 WATT / TYPE LUMENS 400 MH / 250 HPS 250 MH / 250 HPS 61,000 48,000 PRORATION FACTOR .73 .57 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 77 61 49 41 34 29 25 22 19 16 14 70 66 60 54 49 45 41 38 35 32 30 27 70 50 30 66 66 57 55 50 46 44 39 38 34 34 29 30 25 24 22 24 20 22 17 20 16 10 66 52 43 36 30 25 22 19 16 14 13 50 45 39 34 30 26 23 21 19 17 15 14 50 30 45 38 32 27 23 20 18 16 14 12 11 10 45 36 30 25 21 18 15 13 12 10 9 50 26 23 20 17 15 14 12 11 10 8 7 30 30 26 22 19 16 14 12 10 9 8 7 6 10 50 26 9 21 7 18 6 15 6 12 5 11 4 9 4 8 4 7 3 5 3 5 3 10 30 9 7 6 5 5 4 3 3 3 2 2 10 9 7 6 5 4 4 3 3 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 76 69 62 57 52 47 43 40 37 34 32 80 50 30 76 76 65 63 57 53 50 45 44 38 39 33 35 29 31 25 28 22 25 20 23 18 10 76 60 49 40 34 29 25 21 18 16 14 70 65 59 53 48 44 40 37 34 31 29 27 70 50 30 65 65 56 54 49 45 43 39 38 33 33 29 30 25 27 22 24 19 22 17 20 15 10 65 52 42 35 29 25 21 18 16 14 12 50 44 38 33 29 26 23 21 18 17 15 14 50 30 44 37 31 27 23 20 17 15 14 12 11 10 44 36 29 25 21 18 15 13 11 10 9 Lumens % Lamp 0 0 0 479 25535 43808 67950 82094 82573 0.0 0.0 0.0 0.4 23.7 40.6 63.0 76.2 76.6 % Fixt. 0.0 0.0 0.0 0.6 30.9 53.1 82.3 99.4 100.0 TOTAL LUMINAIRE EFFICIENCY = 76.6% COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD 80 50 30 77 77 67 64 58 53 51 45 45 39 40 34 35 29 32 26 28 23 26 20 23 18 Test Number ■ E437-1R / ITL48906 Catalog Number ■ Size 3 MH Luminaire ■ Forward throw distribution ■ Premium hammertone metal reflector ■ Clear flat glass lens ■ Fixture tilted 25 degrees below horizontal Lamps ■ (1) 1000-watt BT37 clear metal halide ■ Rated 107,800, horizontal position Ballasts ■ One magnetic ZONAL LUMEN SUMMARY % Fixt. TOTAL LUMINAIRE EFFICIENCY = 80.7% RC RW 0 1 2 3 4 5 6 7 8 9 10 90˚ 50 26 22 19 17 15 13 12 11 10 9 30 30 26 21 18 16 14 12 10 9 8 7 10 50 26 8 21 7 17 6 15 6 12 5 10 4 9 4 8 4 7 3 6 3 3 WATT / TYPE LUMENS 400 MH 33,000 PRORATION FACTOR .31 COEFFICIENTS OF UTILIZATION, ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 10 30 8 7 6 5 4 4 3 3 3 2 2 10 8 7 6 5 4 3 3 3 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 RC RW 0 1 2 3 4 5 6 7 8 9 10 70 73 67 60 55 50 46 42 39 36 33 31 80 50 30 73 73 63 61 55 51 48 43 43 37 38 32 34 28 30 24 27 22 24 19 22 17 10 73 58 47 39 33 28 24 21 18 16 14 70 63 57 52 47 43 39 36 33 30 28 26 70 50 30 63 63 54 52 47 44 42 37 37 32 32 28 29 24 26 21 23 19 21 17 19 15 10 63 50 41 34 29 24 21 18 16 14 12 50 43 37 32 29 25 22 20 18 16 15 13 50 30 43 36 30 26 22 19 17 15 13 12 10 10 43 35 29 24 20 17 15 13 11 10 9 50 25 21 19 17 15 13 12 10 9 9 8 30 30 25 21 18 15 13 11 10 9 8 7 6 10 50 25 8 20 7 17 6 14 5 12 5 10 4 9 4 8 3 7 3 6 3 5 3 10 30 8 7 6 5 4 4 3 3 3 2 2 10 8 7 5 5 4 3 3 3 2 2 2 0 0 1 0 0 0 0 0 0 0 0 0 0 The following indirect fixtures were tested in accordance with IES recommendations for laboratory tests by independant testing laboratories ■ 33 ECHO 1 and 1.5 Spacing / Footcandle Tables The tables below were generated from photometric tests on pages 30 - 33. They illustrate initial footcandle levels between two center fixtures based on testing of four or more fixtures and a 10 foot ceiling (20 feet for 250 T15 MH). Size 1 and 1.5 150 RSC MH / E435-3R 3’ Ceiling 188 320 359 325 265 197 155 125 100 79 Wall 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ Floor 4’ SPACING 167 155 167 313 295 313 345 327 345 314 307 314 254 251 254 193 193 193 153 154 153 125 124 125 100 99 100 79 78 79 188 320 359 325 265 197 155 125 100 79 168 277 302 270 216 161 125 100 80 64 196 fc / 2.1:1 Size 1 and 1.5 Ceiling Wall 19 52 54 47 44 38 29 24 19 16 Floor 131 238 251 221 178 132 103 84 67 54 6’ SPACING 92 73 92 179 151 179 205 190 205 197 189 197 165 155 165 128 125 128 102 103 102 84 86 84 68 70 68 55 55 55 131 238 251 221 178 132 103 84 67 54 159 258 278 240 189 136 106 84 67 53 156 250 267 223 172 121 92 74 58 46 126 277 236 202 159 115 90 72 58 46 135 fc / 2.1:1 7’ SPACING 82 53 53 82 157 112 112 157 176 143 143 176 170 149 149 170 141 129 129 141 110 105 105 110 88 87 87 88 71 72 72 71 58 59 59 58 47 47 47 47 126 227 236 202 159 115 90 72 58 46 156 250 267 223 172 121 92 74 58 46 9 21 25 24 23 20 17 13 11 9 12 36 38 29 26 22 17 14 11 9 16 45 45 33 29 24 18 14 12 9 5 15 21 22 18 14 11 9 7 6 7 27 31 28 21 15 11 9 7 6 8 37 37 33 23 15 11 9 7 6 Ceiling Wall 11 42 46 42 33 25 18 14 12 11 Floor 4’ SPACING 16 18 16 46 41 46 51 47 51 45 43 45 42 42 42 36 36 36 29 29 29 23 23 23 19 19 19 16 15 16 19 52 54 47 44 38 29 24 19 16 17 47 49 39 37 31 24 19 15 13 5’ SPACING 14 13 13 14 39 29 29 39 43 35 35 43 37 34 34 37 34 32 32 34 29 28 28 29 23 23 23 23 19 19 19 19 15 16 16 15 13 13 13 13 17 47 49 39 37 31 24 19 15 13 16 45 46 35 32 27 20 16 13 11 12 37 39 32 29 25 20 16 13 11 27 fc / 2.0:1 4’ SPACING 12 10 12 34 28 34 41 39 41 40 40 40 33 32 33 24 24 24 18 18 18 14 14 14 12 12 12 11 11 11 11 42 46 42 33 25 18 14 12 11 9 39 41 37 28 20 15 12 10 9 24 fc / 2.4:1 24 fc / 2.4:1 WATT / TYPE 150 HQI 70 HQI 70 MH PRORATION FACTOR .89 .44 .41 Multiply numbers in table by the above proration factors 117 fc / 2.3:1 6’ SPACING 10 8 10 23 18 23 28 24 28 28 26 28 27 25 27 24 22 24 19 19 19 16 16 16 13 13 13 11 11 11 12 37 39 32 29 25 20 16 13 11 16 45 46 35 32 27 20 16 13 11 16 45 45 33 29 24 18 14 12 9 12 36 38 29 26 22 17 14 11 9 22 fc / 2.8:1 7’ SPACING 9 5 5 21 13 13 25 17 17 24 20 20 23 20 20 20 18 18 17 16 16 13 13 13 11 11 11 9 9 9 19 fc / 3.9:1 26 FL QUAD / D435-20 2.5’ 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ 159 258 278 240 189 136 106 84 67 53 160 fc / 2.0:1 33 fc / 2.19:1 Size 1.5 168 277 302 270 216 161 125 100 80 64 150 DC BAY T4 QTZ / E435-10R 2.5’ 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ 5’ SPACING 143 112 112 143 263 220 220 263 284 254 254 284 256 241 241 256 208 197 197 208 156 153 153 156 123 124 124 123 100 102 102 100 81 82 82 81 65 64 64 65 Center line of the fixture Average footcandles / Average:Minimum uniformity 2000 SPI Lighting ■ 34 5’ SPACING 9 9 9 30 20 20 36 28 28 34 30 30 27 26 26 20 20 20 15 15 15 12 12 12 10 10 10 9 9 9 20 fc / 2.2:1 9 30 36 34 27 20 15 12 10 9 9 39 41 37 28 20 15 12 10 9 9 38 39 34 25 17 13 10 8 8 9 28 33 30 23 17 13 10 8 8 6’ SPACING 6 7 6 17 13 17 23 18 23 25 22 25 21 21 21 16 16 16 13 12 13 10 10 10 8 9 8 8 7 8 17 fc / 2.8:1 9 28 33 30 23 17 13 10 8 8 9 38 39 34 25 17 13 10 8 8 8 37 37 33 23 15 11 9 7 6 7 27 31 28 21 15 11 9 7 6 7’ SPACING 5 6 6 15 9 9 21 14 14 22 16 16 18 16 16 14 13 13 11 11 11 9 9 9 7 7 7 6 7 7 15 fc / 3.0:1 WATT / TYPE 300 T3 150 T4 PRORATION FACTOR .58 .27 Multiply numbers in table by the above proration factors ECHO 1.5 and 2 Size 1.5 and 2 3’ Ceiling Wall 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ Floor Size 2 Spacing / Footcandle Tables 55 TT FL / E435-23 4’ SPACING 28 30 30 30 28 103 96 90 96 103 150 145 136 145 150 133 132 132 132 133 99 100 98 100 99 72 71 71 71 72 54 54 54 54 54 42 42 42 42 42 35 35 35 35 35 30 32 32 32 30 5’ SPACING 21 22 26 26 22 21 91 82 66 66 82 91 130 120 104 104 120 130 114 108 101 101 108 114 83 81 78 78 81 83 59 58 57 57 58 59 44 44 43 43 44 44 35 35 35 35 35 35 29 29 29 29 29 29 25 25 26 26 25 25 74 fc / 2.6:1 60 fc / 2.9:1 16 51 90 87 70 52 39 31 26 23 6’ SPACING 15 15 15 39 33 39 73 65 73 76 72 76 64 63 64 50 49 50 38 38 38 31 31 31 26 26 26 23 23 23 16 51 90 87 70 52 39 31 26 23 12 54 94 85 66 47 35 27 23 20 16 56 99 92 72 53 39 31 26 23 12 47 85 80 63 46 34 27 23 19 7’ SPACING 12 15 15 34 25 25 64 50 50 66 57 57 56 51 51 43 41 41 33 32 32 27 26 26 22 22 22 20 20 20 47 fc / 3.1:1 12 34 64 66 56 43 33 27 22 20 12 47 85 80 63 46 34 27 23 19 WATT / TYPE 50 TT 40 TT 39 TT 12 54 94 85 66 47 35 27 23 20 PRORATION FACTOR .83 .66 .60 Multiply numbers in table by the above proration factors 40 fc / 3.3:1 250 T15 MH / E436-8 5’ 35 95 105 112 109 105 97 85 73 62 54 47 41 36 32 29 26 24 21 Ceiling Wall 19.5’ 18.5’ 17.5’ 16.5’ 15.5’ 14.5’ 13.5’ 12.5’ 11.5’ 10.5 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ 16 56 99 92 72 53 39 31 26 23 32 82 101 108 109 104 94 82 71 61 52 46 40 35 32 28 26 23 21 27 69 93 100 102 100 92 80 69 59 51 44 39 35 31 28 25 23 21 8’ SPACING 22 27 22 27 32 35 64 62 64 69 82 95 84 81 84 93 101 105 91 86 91 100 108 112 97 95 97 102 109 109 96 95 96 100 104 105 88 87 88 92 94 97 78 77 78 80 82 85 67 66 67 69 71 73 57 57 57 59 61 62 49 49 49 51 52 54 43 43 43 44 46 47 38 38 38 39 40 41 34 34 34 35 35 36 30 30 30 31 32 32 28 27 28 28 28 29 25 25 25 25 26 26 23 23 23 23 23 24 21 21 21 21 21 21 Floor 30 87 95 100 96 92 83 72 61 52 44 39 34 30 27 24 22 20 18 16 27 74 90 96 96 90 80 69 59 50 43 37 33 29 26 23 21 19 18 16 22 59 80 85 87 84 76 66 56 48 42 36 32 28 25 23 21 19 17 16 16 51 67 73 77 76 70 62 54 46 40 35 31 28 25 22 20 19 17 16 56 fc / 2.9:1 WATT / TYPE 400 T15 10’ SPACING 21 22 21 45 42 45 59 56 59 64 61 64 69 66 69 70 68 70 66 65 66 59 59 59 52 51 52 45 44 45 39 39 39 34 34 34 30 30 30 27 27 27 24 24 24 22 22 22 20 20 20 18 18 18 17 17 17 16 16 16 16 51 67 73 77 76 70 62 54 46 40 35 31 28 25 22 20 18 17 16 22 59 80 85 87 84 76 66 56 48 42 36 32 28 25 23 21 19 17 16 29 84 90 95 91 87 77 65 55 46 39 34 29 26 23 21 19 17 15 14 27 30 74 87 90 95 96 100 96 96 90 92 80 83 69 72 59 61 50 52 43 44 37 39 33 34 29 30 26 27 23 24 21 22 19 20 18 18 16 16 25 71 86 90 90 84 73 62 52 44 37 32 28 25 22 20 18 16 15 14 19 55 74 78 80 76 68 58 49 41 35 31 27 24 22 19 18 16 15 14 12 45 60 64 68 66 60 53 45 39 34 30 26 23 21 19 17 16 15 13 45 fc / 2.8:1 17 36 48 52 56 57 54 48 42 37 32 28 25 23 20 19 17 16 14 13 12’ SPACING 17 16 17 30 28 30 40 38 40 45 43 45 48 45 48 50 48 50 49 48 49 43 45 46 41 40 41 36 35 36 31 31 32 28 28 28 25 25 25 22 22 22 20 20 20 18 18 18 17 17 17 15 15 15 14 14 14 13 13 13 17 36 48 52 56 57 54 48 42 37 34 28 25 23 20 19 17 16 14 13 12 45 60 64 68 66 60 53 45 39 35 30 26 23 21 19 17 16 15 13 19 55 74 78 80 76 68 58 49 41 37 31 27 24 22 19 18 16 15 14 15 71 86 90 90 84 73 62 52 44 37 32 28 25 22 20 18 16 15 14 29 84 90 95 91 87 77 65 53 46 39 34 29 26 23 21 19 17 15 14 38 fc / 3.1:1 PRORATION FACTOR 1.7 Multiply numbers in table by the above proration factors Size 1.5 32 T8 FL - Continuous Row of 4’ fixtures 2’ Ceiling Wall 9.5’ 8.5’ 7.5’ 6.5’ 5.5’ 4.5’ 3.5’ 2.5’ 1.5 .5’ Floor 17 73 96 82 60 44 34 26 21 18 4’ SPACING 19 19 19 73 73 73 97 98 97 83 83 83 60 60 60 44 44 44 33 33 33 26 26 26 21 21 21 19 19 19 47 fc / 2.2:1 2.5’ 17 73 96 82 60 44 34 26 21 18 21 64 90 85 66 50 38 29 24 20 4’ SPACING 23 23 23 65 65 65 91 91 91 85 86 85 67 67 67 50 50 50 38 38 38 29 30 29 24 24 24 21 21 21 49 fc / 2.5:1 3’ 21 64 90 85 66 50 38 29 24 20 25 62 86 86 71 55 42 32 26 21 4’ SPACING 27 27 27 63 63 63 87 87 87 86 87 86 71 71 71 55 55 55 42 42 42 32 32 32 26 26 26 22 22 22 51 fc / 2.4:1 4’ 25 62 86 86 71 55 42 32 26 21 39 66 83 86 75 61 45 35 27 22 4’ SPACING 41 41 41 66 66 66 83 83 83 86 87 86 74 74 74 60 60 60 46 46 46 35 35 35 27 28 27 23 23 23 39 66 83 86 75 61 45 35 27 22 54 fc / 2.5:1 ■ 35 ECHO ■ Technical Lamp data compiled from manufacturer’s current catalogs. All fixtures are shipped with lamp(s) and ballast. SPI supplies fluorescent lamps four feet in length or greater by special order only; please consult factory. *Lamps available but not supplied standard; please consult. Lamp Data LAMP TYPE WATTAGE LUMENS LAMP LIFE K° TEMP CRI Metal Halide ■ T6 DE* 70 6000 15000 3000 83 ■ T6 DE* 150 13500 15000 3000 85 ■ ED17 175 15000 10000 3700 70 ■ ET18 250 20000 7500 4000 65 ■ ET18 400 33000 15000 4000 65 ■ BT37 400 32000 15000 4000 65 ■ BT37 1000 108000 9000 3800 65 250 28000 24000 2100 22 High Pressure Sodium ■ E18 ■ E18 400 51000 24000 2100 22 ■ E25 1000 140000 24000 2100 22 Fluorescent ■ Quad 26 1800 10000 Available in 82 ■ Triple 32 2400 10000 3000, 3500 82 ■ Triple 42 3200 10000 or 4100 82 ■ Twin 39 2850 12000 82 ■ Twin 40 3150 20000 82 ■ Twin 50 4000 14000 82 ■ Twin 55 4800 12000 82 NOMINAL LENGTH ■ Linear T5*/HO 24” 14/24 1350/2000 20000 Available in 85 ■ Linear T5*/HO 36” 21/39 2100/3500 20000 3000, 3500 85 ■ Linear T5*/HO 48” 28/54 2900/5000 20000 or 4100 ■ Linear T5* 60” 35 3650 20000 85 ■ Linear T8* 48” 32 2850 20000 75 85 Halogen ■ T3 300 5770 2000 3000 100 ■ T3 350/500 10000 2000 3100 100 ■ T4 150 2700 2000 2950 100 ■ T10 250 4400 2000 3000 100 ■ T3 900 32000 2000 3200 100 ■ T6 1000 23400 2000 3200 100 2000 SPI Lighting ■ 36 ECHO .5 Miniature Size - Superior Performance SPI proudly introduces Size .5 as part of the expanded Echo Series. Features include an extruded aluminum housing, wet location construction, T5 fluorescent lamps including HO, integral ballast(s), double cluster pendants and multiple mounting methods including wall, ceiling, cove, stem and hub. ECHO .5 CROSS SECTION ACTUAL SIZE COVE MOUNT ACTUAL SIZE ECHO ■ Technical ■ Credits SPI’s expanded Echo Series is not a repetition, but an evolution. Adding fluorescent lamping to metal halide and quartz-halogen. Moving outside with new weather-resistant housings. Integrating ballast options to simplify form. And offering a palette of sizes, housings and mounting methods that make Echo suitable for numerous applications, blending functional design with superior performance — again. And again and again. 1 INTRODUCTION Standard Remote Ballast Kit ■ ■ ■ ■ ■ ■ ■ ■ Remote Dual tap, 120 / 277 volt operation Encased and potted Thermally protected CWA-HPF design End-mounted wire compartment 16 gauge mounting legs Field assembly required C Installation: Architects: Engineering: Lighting: Photography: Fixture(s): Bellevue Regional Library / Bellevue, WA Zimmer Gunsul Frasca Partnership Sparling Associates Candela, Consultant Timothy Hursley ECR 3803 / 1000 BT37 MH 1 Installation: Architects: Engineering: Photography: Fixture(s): Buffalo Bills Training Center / Buffalo, NY Duchscherer Oberst Design Wilson, Klaes, Brucker & Worden Paul Maze, Phototech Studio EDR 3803 SM and DC / 1000 BT37 MH Installation: Architects: Engineering: Photography: Fixture(s): Rockford High School / Rockford, MI Greiner, Inc. Greiner, Inc. Phil Schaafsma Photography EER 2403 / Scoop: 175 ED17 Med MH 10 Remote Ballast Tray - RPI ■ ■ ■ ■ ■ ■ 2-3 ■ COMPONENTS / APPLICATIONS Optional Remote Dual tap, 120 / 277 volt operation Encased and potted Thermally protected CWA-HPF design Universal mounting brackets for 1/2” EMT, lathing channels or hanger brackets 2 12 ■ ■ Housing, mounting bracket and fasteners constructed of non-ferrous materials Small electrical components such as lamp and sockets may contain ferrous materials Installation: 4 Photography: Tom Davenport, BBD Fixture(s): EDR SR 1403 / Semi-Recessed: 150 T6 RSC MH Fuse Option - F ■ ■ ■ Sized appropriately for electrical requirements Fuse holder and fuse supplied by factory Some fuse holders may require field installation 11 5 O’Hare International Airport - Terminal 5, Rotunda Chicago, IL Architects: Group One Design: Perkins & Will, Heard & Associates and Consoer Townsend & Associates Engineering: Hansen Palmer Associates, Ltd. Lighting: David A. Mintz Photography: Nick Merrick, Hedrich-Blessing Fixture(s): EDR 5603 with column-mount bracket / (2) 400 T15 MH 6 Installation: Architects: Photography: Fixture(s): Ford XL Training Center / Allen Park, MI Palladia Architects, Inc. Dave Knox, Regan Productions ECR QC 1743 / 350 HIR T3 RSC QTZ 7 Installation: Architects: Lighting: Photography: Fixture(s): Corporate Office / Chicago, IL Powell/Kleinschmidt Inc. Gary Steffy Lighting Design Inc. Jon Miller, Hedrich Blessing EDR 4403 / 150 T6 RSC MH 8 Installation: 9 Installation: Standby Lighting Option - Q ■ ■ ■ Emergency Lighting Option, fluorescent - EM ■ 4-5 SIZE 1 6-9 SIZE 1.5 10 - 15 SIZE 2 16 - 17 SIZE 3 18 - 20 Accessories 100 watt quartz lamp and switch relay Provides temporary lighting, when power is on, until the metal halide lamp reaches 30% of lighting output Remote mounted relay with remote ballast fixtures ECR and EDR ■ ■ ■ ■ ■ 1 A minimum of 50 fc is achieved with 1000 watt Echos, stem-mounted 56 feet above the floor. Every sixth fixture is double-clustered for additional light on the running track. ■ ■ Integral ballast Remote ballast for 12” and 19” fixtures Operates lamp a minimum of 90 minutes at approximately 30% output in emergency mode Operates until AC power restored Automatically recharges UL Listed and exceeds NEC/NFPA-LSC emergency illumination requirements Remote mount charge indicator light and test switch For integral mounting of indicator light, please consult factory Dimming, fluorescent - DB ■ ■ ■ VARIATIONS / CUSTOM International Market ■ 21 Optional Mounting 22 - 23 Semi-Recessed 24 - 27 ShapesTM 28 - 29 Cove Mount 180˚ ■ 150˚ ■ 135˚ 10095 15142 90˚ 20190 ■ HID ballasts may hum slightly due to the magnetic action in the core and coil assembly. This hum may be amplified by the resonant qualities of its surroundings such as ceiling, walls, floors or furnishings. Careful consideration of these components within the lighting design will ensure the quietest installation possible. For “library quiet” installations, remote mount ballast or please consult factory. 13 Bay View Branch Library, Milwaukee Public Library Milwaukee, WI Architects: Engberg Anderson Engineering: Harwood Engineering, Consultants Photography: Morley Johnson Fixture(s): EDR 5603 / (2) 400 T15 MH Northwest Community Hospital, Wellness Center / Arlington Heights, IL Architects: OWP & P Engineering: Environmental Systems Design Inc. Lighting: Gerry Zekowski Photography: Paul Schlissman, 1996 Fixture(s): EDT 5603 / (2) 400 T15 MH Installation: Architects: Engineering: Photography: Fixture(s): Waukesha Memorial Hospital / Waukesha, WI The Zimmerman Design Group Uihlein Electric Company, Inc. Purcell Imaging EER 2603 / Scoop: 400 T15 MH ■ 37 E10-00 5047 Available for HO and VHO FL lamps; consult factory Remote fixtures may require additional cords ballast Ballast Sound 105˚ PHOTOMETRY & APPLICATION / TECHNICAL / CREDITS 50 and 60 Hz ballasts available in different voltages; please consult factory Cold Weather Ballasts 165˚ 120˚ 30 - 37 Ballast available for 26 QUAD FL, 32 T8 FL and 39, 40, 50 TT FL lamps only Dimming range: 10% - 100% Please consult factory for dimming system compatibility Installation: ECHO ECHO Boeing Customer Service Center, Flight Simulator Area Renton, WA Architects: Callison Photography: Fred Licht 1995 Fixture(s): ECR 3803 / 1000 BT37 MH 3 MRI Construction - MRI Echo and its components shown in this brochure have United States, Canadian and International patents pending. SPI Lighting, Power Tray and Shapes are registered trademarks Copyright 1999. Specification subject to change without notice. All rights reserved. Printed in the U.S.A. Simplified form, expanded flexibility, superior performance . . . the evolution continues. ECHO SPI Lighting Inc. warrants its products free from defective material and workmanship. SPI will repair or replace at its option, without charge, at our factory within a period of one year from the date of shipment and only after prior written return authorization has been granted. This warranty does not apply to products which have been damaged in shipping, installed or maintained improperly, or altered or repaired outside of SPI’s factory. This warranty only covers equipment manufactured by SPI Lighting Inc. and does not include transportation, labor or installation charges, nor does it apply to any components not manufactured by SPI Lighting Inc. For complete Warranty Information and Term and Conditions of Sale, please contact SPI Lighting or your local representative. ECHO SPI SPI Lighting 10400 North Enterprise Drive Mequon, Wisconsin 53092 E10-00 262 242 1420 FAX 262 242 6414 E-mail spi@spilighting.com www.spilighting.com © 2000 SPI Lighting