OK TPN MCB TPN MCB TPN MCB R Y TPN MCB B TPN MCB DLM EM 6400 SPRING CHARGED EMERGENCY PUSH BUTTON ON OFF TRIP TRIP CKT. HEALTHY SPRING CHARGED AUTO/MANUAL SELECTOR SWITCH F5 63A TPN MCB 10 KA F6 F7 F8 63A TPN MCB 10 KA 63A TPN MCB 10 KA B 0-500 Amp 400 A TPN MCCB 36 KA TRIP CKT. HEALTHY AUTO/MANUAL SELECTOR SWITCH 500 A, TPN, 415 V, 50 Hz, ALUMIN IUM BUSBAR, SUITABLE FOR 50 KA FOR 1 SEC. 63A TPN MCB 10 KA Y 0-500 V DLM EM 6400 400/5A 10 VA CL-1 0-500 Amp EMERGENCY PUSH BUTTON ON OFF TRIP F4 R TPN MCB 0-500 V 400/5A 10 VA CL-1 400 A TPN MCCB 36 KA 500 A, TPN, 415 V, 50 Hz, ALUMIN IUM BUSBAR, SUITABLE FOR 50 KA FOR 1 SEC. F9 63A TPN MCB 10 KA F10 63A TPN MCB 10 KA F11 63A TPN MCB 10 KA 63A TPN MCB 10 KA F12 F13 63A TPN MCB 10 KA F14 63A TPN MCB 10 KA 63A TPN MCB 10 KA F15 F16 F17 F18 F19 F20 F21 F22 F23 F1 63A TPN MCB 10 KA F2 63A TPN MCB 10 KA 1 F3 63A TPN MCB 10 KA 63A TPN MCB 10 KA F4 F5 63A TPN MCB 10 KA F6 63A TPN MCB 10 KA F7 63A TPN MCB 10 KA F8 63A TPN MCB 10 KA F9 63A TPN MCB 10 KA F10 63A TPN MCB 10 KA F11 63A TPN MCB 10 KA F12 63A TPN MCB 10 KA 63A TPN MCB 10 KA F13 F14 63A TPN MCB 10 KA 63A TPN MCB 10 KA F15 F16 63A TPN MCB 16 KA 63A TPN MCB 16 KA F17 63A TPN MCB 16 KA F18 63A TPN MCB 16 KA F19 63A TPN MCB 16 KA F20 63A TPN MCB 16 KA INCOMING ELECTRICAL POWER SUPPLY DETAIL ARE AS FOLLOWS. UTILIZATION VOLTAGE 415 V , 3 PHASE , 4 WIRE , 50 Hz NEUTRAL ARRANGMENT SOLIDLY GROUNDED 2 3 MAIN LT PANEL SHALL BE SINGLE FRONT, FLOOR MOUNTED WITH PROVISION FOR TOP CABLE ENTRY . INCOMERS (ACB) SHALL BE WITH MICRO PROCESSOR BASED PROTECTION. 4 INCOMERs BREAKERS (EB & DG SUPPLY) SHALL BE ELECTRICALLY & MECHANICALLY INTERLOCKED. 5 6 ALL ACB SHALL BE PROVIDED WITH OPERATION COUNTER. ALL ACB & MCCB SHALL BW WITH THERMAL MAGNETIC RELEASE, O/C, E/F & S/C PROTECTION AUXILIARY POWER SUPPLY SHALL BE AS FOLLOWS , ALL EQUIPMENT SHALL BE RATED FOR 230 VAC & 24 VDC CONTINUES OPERATION 7 SWITCHGEAR ANTI-CONDENSATION HEATER SUPPLY SHALL BE 230 VAC. 8 MAIN BUS BARs SHALL BE SUITABLLY-PVC SLEEVED ELECTROLYTIC ALUMINIUM. VENDOR TO PROVIDE THE BUSBAR CALCULATIONS. SERVICE 1 INCOMING ELECTRICAL POWER SUPPLY DETAIL ARE AS FOLLOWS. UTILIZATION VOLTAGE 415 V , 3 PHASE , 4 WIRE , 50 Hz 2 MAIN LT PANEL SHALL BE SINGLE FRONT, FLOOR MOUNTED WITH PROVISION FOR TOP CABLE ENTRY . 3 4 5 6 7 8 9 11 LEGEND INCOMERS (ACB) SHALL BE WITH MICRO PROCESSOR BASED PROTECTION. SYMBOL INCOMERs BREAKERS (EB & DG SUPPLY) SHALL BE ELECTRICALLY & MECHANICALLY INTERLOCKED. ALL ACB SHALL BE PROVIDED WITH OPERATION COUNTER. ALL ACB & MCCB SHALL BW WITH THERMAL MAGNETIC RELEASE, O/C, E/F & S/C PROTECTION AUXILIARY POWER SUPPLY SHALL BE AS FOLLOWS , ALL EQUIPMENT SHALL BE RATED FOR 230 VAC & 24 VDC CONTINUES OPERATION SERVICE VOLTS ACB CLOSING 230 AC EXTERNAL AC SUPPLY UNIT ACB TRIPPING 230 AC/DC SUPPLY POWER DERIVED FROM AC EXTERNAL AC SUPPLY UNIT SPRING CHARGED MOTOR 230 AC EXTERNAL AC SUPPLY UNIT INDICATION 230 AC EXTERNAL AC SUPPLY UNIT AUX. RELAYs & CONTACTORs 230 AC EXTERNAL AC SUPPLY UNIT R Y B DESCRIPTION 9 RYB INDICATION LAMP (LED TYPE) 11 14 15 16 SUPPLY POWER DERIVED FROM AC EXTERNAL AC SUPPLY UNIT AC EXTERNAL AC SUPPLY UNIT 230 AC EXTERNAL AC SUPPLY UNIT 230 AC EXTERNAL AC SUPPLY UNIT 230 AC EXTERNAL AC SUPPLY UNIT LEGEND SYMBOL 24 VDC SUPPLY UNIT SHALL BE PART OF MAIN LT PANEL R Y B ON OFF TRIP DESCRIPTION RYB INDICATION LAMP (LED TYPE) ON, OFF, TRIP INDICATION LAMPS DIRECT SUPPLY TO PANEL. CT & PT RATING AND CHARACTERISTICS SHALL BE CONFIRMED BY THE SWITCHGEAR VENDOR MOULDED CASE CIRCUIT BREAKER THE SWITCHGEAR VENDOR SHALL BE RESPONSIBLE FOR THE COMPLETE DESIGN AS DETAILED IN THE SPECIFICATION . RELEVENT STADARDS AND GOOD ENGINEERING PRACTICE. 12 ON OFF TRIP 13 ON, OFF, TRIP INDICATION LAMPS 14 DIRECT SUPPLY TO PANEL. MAIN BUS BARs SHALL BE SUITABLLY-PVC SLEEVED ELECTROLYTIC ALUMINIUM. VENDOR TO PROVIDE THE BUSBAR CALCULATIONS. MOULDED CASE CIRCUIT BREAKER CT & PT RATING AND CHARACTERISTICS SHALL BE CONFIRMED BY THE SWITCHGEAR VENDOR MINITURE CIRCUIT BREAKER LOCAL/REMOTE (AUTO/MANUAL) SELECTOR SWITCH SHALL BE PROVIDED AS KEY OPERATED TYPE. DLM-1 PANELS SHALL HAVE DOUBLE CONNECTION BODY EARTHING BY ALLUMINIUM EARTHING STRIP. CT, RELAY, METERING, LAMPS ETC. SHOWN ARE INDICATIVE AND MINIMUM. CT, AUX RELAYS, METERS, INDICATING LAMPS, SHALL BE PROVIDED. EB INCOMER & BUS COUPLER ARE 4 POLE , DG INCOMERS ARE 4 POLE AND OUT GOING FEEDERS ARE TPN. ALL MCB SHALL HAVE MINIMUM BREAKING CAPACITY 10 KA. 17 THE ABOVE SYSTEM CONSISTING OF AUTO CHANGE OVER BETWEEN EB & DG SUPPLY USING PLC A V 17 MCCB SHALL BE PROVIDED WITH FACILITIES FOR PADLOCKING IN THE "OFF" POSITION. 17 MCCB SHALL BE INTERLOCKED TO PREVENT THE COMPARTMENT DOOR BEING OPENED UNLESS THE MCCB IS IN THE OPEN POSITION. 17 ALL MCCB SHALL HAVE ADJUSTABLE THERMAL MAGNETIC RELEASE. MINITURE CIRCUIT BREAKER LOCAL/REMOTE (AUTO/MANUAL) SELECTOR SWITCH SHALL BE PROVIDED AS KEY OPERATED TYPE. PANELS SHALL HAVE DOUBLE CONNECTION BODY EARTHING BY ALLUMINIUM EARTHING STRIP. 15 CT, RELAY, METERING, LAMPS ETC. SHOWN ARE INDICATIVE AND MINIMUM. CT, AUX RELAYS, METERS, INDICATING LAMPS, SHALL BE PROVIDED. 16 EB INCOMER & BUS COUPLER ARE 4 POLE , DG INCOMERS ARE 4 POLE AND OUT GOING FEEDERS ARE TPN. 17 ALL MCB SHALL HAVE MINIMUM BREAKING CAPACITY 10 KA. DIGITAL LOAD MANAGER ONLY TO INDICATE AMPER & kW RATING DIGITAL AMMETER DIGITAL VOLTMETER CURRENT TRANSFORMER (CT) 17 EACH VERTICAL SECTION SHALL BE PROVIDED WITH MAXIMUM 3 NOS. OF OUTGOING FEEDERS IN MCCB/SDF AND 2 NO FEEDER CABLE GLAND 17 CT RATING & CHARACTERISTICS SHALL BE CONFIRMED BY SWITHGEAR VENDOR. SPARE FEEDER 17 ON/ OFF/ TRIP INDICATION SHALL BE CONNECTED THROUGH ADD ON BLOCK DLM-1 A V 17 THE ABOVE SYSTEM CONSISTING OF AUTO CHANGE OVER BETWEEN EB & DG SUPPLY USING PLC THE SWITCHGEAR VENDOR SHALL BE RESPONSIBLE FOR THE COMPLETE DESIGN AS DETAILED IN THE SPECIFICATION . RELEVENT STADARDS AND GOOD ENGINEERING PRACTICE. 17 17 AC/DC 230 230 INDICATION AUX. RELAYs & CONTACTORs 24 VDC SUPPLY UNIT SHALL BE PART OF MAIN LT PANEL SWITCHGEAR ANTI-CONDENSATION HEATER SUPPLY SHALL BE 230 VAC. DIGITAL LOAD MANAGER ONLY TO INDICATE AMPER & kW RATING DIGITAL AMMETER DIGITAL VOLTMETER 17 MCCB SHALL BE PROVIDED WITH FACILITIES FOR PADLOCKING IN THE "OFF" POSITION. 12 13 VOLTS ACB CLOSING ACB TRIPPING SPRING CHARGED MOTOR NEUTRAL ARRANGMENT SOLIDLY GROUNDED INSTRUMENTATION A V LM CC TC MDO EDO ASS VSS LVM 17 MCCB SHALL BE INTERLOCKED TO PREVENT THE COMPARTMENT DOOR BEING OPENED UNLESS THE MCCB IS IN THE OPEN POSITION. CURRENT TRANSFORMER (CT) 17 ALL MCCB SHALL HAVE ADJUSTABLE THERMAL MAGNETIC RELEASE. AMMETER VOLTMETER LOAD MANAGER CLOSING COIL TRIPPING COIL MANUAL DRAW OUT ELECTRICAL DRAW OUT AMMETER SELECTOR SWITCH VOLTMETER SELECTOR SWITCH LINE VOLTAGE MONITOR 17 EACH VERTICAL SECTION SHALL BE PROVIDED WITH MAXIMUM 3 NOS. OF OUTGOING FEEDERS IN MCCB/SDF AND 2 NO FEEDER CABLE GLAND 17 CT RATING & CHARACTERISTICS SHALL BE CONFIRMED BY SWITHGEAR VENDOR. 17 ON/ OFF/ TRIP INDICATION SHALL BE CONNECTED THROUGH ADD ON BLOCK 17 SPARE FEEDER PANEL SHALL BE SUITABLE FOR FUTURE EXTENSION FROM BOTH SIDE OF THE PANEL Date: Project: PANEL SHALL BE SUITABLE FOR FUTURE EXTENSION FROM BOTH SIDE OF THE PANEL GFC Date: Project: AUDITORIUM WORKS AT SUKAST , JAMMU HVAC PANELPDS/ELE/HVAC-1/15-16/004 SCHEMATIC DIAGRAM AUDITORIUM WORKS AT SUKAST , JAMMU HVAC PANELPDS/ELE/HVAC-1/15-16/005 SCHEMATIC DIAGRAM 29.03.2016 AJAY MENGI & ASSOCIATES Scale: ARCHITECTS , INTERIOR DESIGNERS & PLANNERS GANDHI NAGAR, AMMETER VOLTMETER LOAD MANAGER CLOSING COIL TRIPPING COIL MANUAL DRAW OUT ELECTRICAL DRAW OUT AMMETER SELECTOR SWITCH VOLTMETER SELECTOR SWITCH LINE VOLTAGE MONITOR HVAC PANEL-2 SCHEMATIC DIAGRAM HVAC PANEL-1 SCHEMATIC DIAGRAM GFC INSTRUMENTATION A V LM CC TC MDO EDO ASS VSS LVM POWER DISTRIBUTION SYSTEM F-261,INDUSTRIAL AREA PHASE-8B,MOHALI,PUNJAB,160059 NTS Drawn By: KUSHAL TPN MCB TPN MCB R Y B TPN MCB 0-500 V DLM EM 6400 250/5A 10 VA CL-1 3 0-300 Amp 250 A TPN MCCB 36 KA EMERGENCY PUSH BUTTON ON OFF TRIP SPRING CHARGED TRIP CKT. HEALTHY AUTO/MANUAL SELECTOR SWITCH 500 A, TPN, 415 V, 50 Hz, ALUMIN IUM BUSBAR, SUITABLE FOR 50 KA FOR 1 SEC. F1 F2 F3 F4 63A TPN MCB 10 KA 1 63A TPN MCB 10 KA 63A TPN MCB 10 KA F5 63A TPN MCB 10 KA F6 63A TPN MCB 10 KA F7 63A TPN MCB 10 KA F8 63A TPN MCB 16 KA 63A TPN MCB 16 KA INCOMING ELECTRICAL POWER SUPPLY DETAIL ARE AS FOLLOWS. UTILIZATION VOLTAGE 415 V , 3 PHASE , 4 WIRE , 50 Hz NEUTRAL ARRANGMENT SOLIDLY GROUNDED 2 MAIN LT PANEL SHALL BE SINGLE FRONT, FLOOR MOUNTED WITH PROVISION FOR TOP CABLE ENTRY . 3 INCOMERS (ACB) SHALL BE WITH MICRO PROCESSOR BASED PROTECTION. 4 INCOMERs BREAKERS (EB & DG SUPPLY) SHALL BE ELECTRICALLY & MECHANICALLY INTERLOCKED. 5 ALL ACB SHALL BE PROVIDED WITH OPERATION COUNTER. ALL ACB & MCCB SHALL BW WITH THERMAL MAGNETIC RELEASE, O/C, E/F & S/C PROTECTION 6 AUXILIARY POWER SUPPLY SHALL BE AS FOLLOWS , ALL EQUIPMENT SHALL BE RATED FOR 230 VAC & 24 VDC CONTINUES OPERATION SERVICE 7 VOLTS AC/DC SUPPLY POWER DERIVED FROM ACB CLOSING 230 AC EXTERNAL AC SUPPLY UNIT ACB TRIPPING 230 AC EXTERNAL AC SUPPLY UNIT SPRING CHARGED MOTOR 230 AC EXTERNAL AC SUPPLY UNIT INDICATION 230 AC EXTERNAL AC SUPPLY UNIT AUX. RELAYs & CONTACTORs 230 AC EXTERNAL AC SUPPLY UNIT SYMBOL R Y B ON MAIN BUS BARs SHALL BE SUITABLLY-PVC SLEEVED ELECTROLYTIC ALUMINIUM. VENDOR TO PROVIDE THE BUSBAR CALCULATIONS. 9 CT & PT RATING AND CHARACTERISTICS SHALL BE CONFIRMED BY THE SWITCHGEAR VENDOR 11 LEGEND 24 VDC SUPPLY UNIT SHALL BE PART OF MAIN LT PANEL OFF TRIP DESCRIPTION RYB INDICATION LAMP (LED TYPE) ON, OFF, TRIP INDICATION LAMPS SWITCHGEAR ANTI-CONDENSATION HEATER SUPPLY SHALL BE 230 VAC. 8 DIRECT SUPPLY TO PANEL. THE SWITCHGEAR VENDOR SHALL BE RESPONSIBLE FOR THE COMPLETE DESIGN AS DETAILED IN THE SPECIFICATION . RELEVENT STADARDS AND GOOD ENGINEERING PRACTICE. MOULDED CASE CIRCUIT BREAKER 12 13 MINITURE CIRCUIT BREAKER LOCAL/REMOTE (AUTO/MANUAL) SELECTOR SWITCH SHALL BE PROVIDED AS KEY OPERATED TYPE. 14 PANELS SHALL HAVE DOUBLE CONNECTION BODY EARTHING BY ALLUMINIUM EARTHING STRIP. 15 CT, RELAY, METERING, LAMPS ETC. SHOWN ARE INDICATIVE AND MINIMUM. CT, AUX RELAYS, METERS, INDICATING LAMPS, SHALL BE PROVIDED. 16 EB INCOMER & BUS COUPLER ARE 4 POLE , DG INCOMERS ARE 4 POLE AND OUT GOING FEEDERS ARE TPN. 17 ALL MCB SHALL HAVE MINIMUM BREAKING CAPACITY 10 KA. DLM-1 A 17 THE ABOVE SYSTEM CONSISTING OF AUTO CHANGE OVER BETWEEN EB & DG SUPPLY USING PLC V DIGITAL LOAD MANAGER ONLY TO INDICATE AMPER & kW RATING DIGITAL AMMETER DIGITAL VOLTMETER 17 MCCB SHALL BE PROVIDED WITH FACILITIES FOR PADLOCKING IN THE "OFF" POSITION. 17 MCCB SHALL BE INTERLOCKED TO PREVENT THE COMPARTMENT DOOR BEING OPENED UNLESS THE MCCB IS IN THE OPEN POSITION. CURRENT TRANSFORMER (CT) 17 ALL MCCB SHALL HAVE ADJUSTABLE THERMAL MAGNETIC RELEASE. 17 EACH VERTICAL SECTION SHALL BE PROVIDED WITH MAXIMUM 3 NOS. OF OUTGOING FEEDERS IN MCCB/SDF AND 2 NO FEEDER 17 CT RATING & CHARACTERISTICS SHALL BE CONFIRMED BY SWITHGEAR VENDOR. 17 ON/ OFF/ TRIP INDICATION SHALL BE CONNECTED THROUGH ADD ON BLOCK 17 CABLE GLAND SPARE FEEDER INSTRUMENTATION A V LM CC TC MDO EDO ASS VSS LVM AMMETER VOLTMETER LOAD MANAGER CLOSING COIL TRIPPING COIL MANUAL DRAW OUT ELECTRICAL DRAW OUT AMMETER SELECTOR SWITCH VOLTMETER SELECTOR SWITCH LINE VOLTAGE MONITOR PANEL SHALL BE SUITABLE FOR FUTURE EXTENSION FROM BOTH SIDE OF THE PANEL HVAC PANEL-3 SCHEMATIC DIAGRAM Date: Project: GFC AUDITORIUM WORKS AT SUKAST , JAMMU HVAC PANELPDS/ELE/HVAC-1/15-16/006 SCHEMATIC DIAGRAM AJAY MENGI & ASSOCIATES Scale: ARCHITECTS , INTERIOR DESIGNERS & PLANNERS GANDHI NAGAR, Drawn By: 29.03.2016 NTS KUSHAL POWER DISTRIBUTION SYSTEM F-261,INDUSTRIAL AREA PHASE-8B,MOHALI,PUNJAB,160059 AJAY MENGI & ASSOCIATES Scale: ARCHITECTS , INTERIOR DESIGNERS & PLANNERS GANDHI NAGAR, Drawn By: 29.03.2016 NTS KUSHAL POWER DISTRIBUTION SYSTEM F-261,INDUSTRIAL AREA PHASE-8B,MOHALI,PUNJAB,160059