Largent Upgrade Kits - Architectural Area Lighting

advertisement
Largent™ LED Upgrade Kits – SLVT-LK TYPE
FEATURES
• LifeShield™ thermal protection
• Dimmable drivers
• 3000K, 4200K and 5100K CCT
• Integral surge protection
• Reliable, efficient operation
• Type II, III, IV, and V distributions
SPECIFICATIONS
• IP Rating: 66
ORDERING INFORMATION
UPGRADE KIT
1
2
3
Light Engine
CCT
Drive Current
SLVT-LK
1. LIGHT ENGINE
LED Hubbell TIR optics
Y4-32LED
Y2-32LED
Y5-32LED
Y3-32LED
2. COLOR TEMPERATURE
3K4K5K
ARCHITECTURAL AREA LIGHTING
16555 East Gale Ave. | City of Industry | CA 91745
P 626.968.5666 | F 626.369.2695 | www.aal.net
Copyright © 2014 | Rev 2.15
JOB
TYPE
NOTES
3. DRIVE CURRENT
700450
| 1 |
Largent™ LED Upgrade Kits – SLVT-LK TYPE
LUMINAIRE PERFORMANCE
Ordering Code
Optical
System
LED
Upgrade
Kit
Secondary
3K
Lens or Distribution
Light Engine
Shield
Delivered Efficacy
Lumens (Lm/W)
Flat Clear
(Standard)
4K
5K
BUG Rating Delivered Efficacy BUG Rating Delivered Efficacy
B U G Lumens (Lm/W) B U G Lumens (Lm/W)
BUG Rating
B
U
G
TYPE 2
Y2-32LED
3672
50
1
0
1
4925
67
1
0
1
5391
73
2
0
1
TYPE 3
Y3-32LED
3487
47
1
0
1
4675
63
1
0
1
5118
69
1
0
1
TYPE 4
TYPE 5
TYPE 2
TYPE 3
TYPE 4
TYPE 5
Y4-32LED
Y5-32LED
Y2-32LED
Y3-32LED
Y4-32LED
Y5-32LED
3685
3325
2350
2232
2359
2128
50
45
49
46
49
44
1
2
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
4941
4880
3152
2992
3162
2853
67
66
66
62
66
59
1
3
1
1
1
2
0
0
0
0
0
0
1
1
1
1
1
1
5409
4880
3450
3275
3462
3123
73
66
72
68
72
65
1
3
1
1
1
2
0
0
0
0
0
0
1
1
1
1
1
1
Drive System Watts
Current
700
75
450
48
ELECTRICAL CHARACTERISTICS
Driver
Optical System
LED Upgrade Kit
LED
Drive
mA
System
Watts
700
700
75
450
450
48
Ordering Code
32LED
Line Voltage
Amps AC
VAC
120
277
0.6
0.3
0.4
0.2
120-277
HZ
50/60
Min.
Power
Factor
Max
THD
(%)
Operating
Temp.
Range
Dimming
Range
≥.9
20
-30°C to
+40°C
10% to
100%
Dimming
Source current out of Absolute voltage range on
0-10V purple wire
0-10V (+) purple wire
Max
Min
Typical
Max
Min
Typical
0 mA
-
2 mA
-2.0 V
-
+15 V
LED COLOR
Consult factory for Amber, Turtle Friendly, Gulf Coast and
Observatory applications.
Ordering Code
4K
5K
3000K
5100K
4200K
2800K – 3175K 3800K – 4600K 4600K – 5600K
≥ 80
≥ 70
≥ 70
3K
CCT Average
CCT Range
CRI Minimum
TM-21 LIFETIME CALCULATION
Optical System Ordering Code
MicroCore
32LED
Ambient Environment ° C
15
25
40
Projected Lumen Maintenance (% vs. Khrs)
15
25
50
TM-21* 60
100
98
98
98
ARCHITECTURAL AREA LIGHTING
16555 East Gale Ave. | City of Industry | CA 91745
P 626.968.5666 | F 626.369.2695 | www.aal.net
Copyright © 2014 | Rev 2.15
98
98
97
JOB
TYPE
NOTES
97
97
96
97
96
95
96
95
92
Reported L70
>60Khrs
| 2 |
Largent™ LED Upgrade Kits – SLVT-LK TYPE
SPECIFICATIONS
OPTICAL MODULE
INSTALLATION
• Light emitting diode (LED) assembly
shall be sealed to a die-cast anodized
aluminum heat sink with an injection
molded silicone rubber gasket and
stainless steel bezel, IP66.
• Existing luminaires shall be required
to be taken down for disassembly
of pre-existing optical and electrical
components.
• LED optics shall be injection molded
PMMA acrylic and be mounted to a
metal printed circuit board with a uniform
conformal coating over the panel surface
and electrical features.
ELECTRICAL
• Upgrade kit shall have integral surge
protection that shall be U.L. recognized
and have a surge current rating of
10,000 Amps using the industry
standard 8/20uSec wave and surge
rating of 372J.
• Drivers shall be U.L recognized with an
inrush current maximum of <20.0 Amps
maximum at 230VAC.
• Estimated time for installation of the
upgrade kit into an existing luminaire is
25 minutes.
WARRANTY / TERMS AND CONDITIONS
OF SALE
Download:
http://www.hubbelllighting.com/resources/
warranty/
AAL reserves the right to change product
specifications without notice.
SERVICING
• The electrical assembly shall be
mounted to a prewired internal service
tray and accessed by loosening four
captive bolts and lifting off the top of the
luminaire.
CERTIFICATION
• Upgrade kits shall be listed with ETL
for outdoor, wet location use, UL1598,
UL 8750 and Canadian CSA Std. C22.2
no.250. IP65.
• Existing luminaires may not have 0-10V
control leads in place prior to the
upgrade kit, consult factory for dimming
and control solutions.
• Drivers shall not be compatible with
current sourcing dimmers, consult
factory for current list of known
compatible dimming systems, approved
dimmers include Lutron Diva AVTV,
Lutron Nova NFTV and NTFTV.
• LifeShield™ shall be provided with all
configurations for added protection in
the event of abnormally excessive
ARCHITECTURAL AREA LIGHTING
16555 East Gale Ave. | City of Industry | CA 91745
P 626.968.5666 | F 626.369.2695 | www.aal.net
Copyright © 2014 | Rev 2.15
JOB
TYPE
NOTES
| 3 |
Download