VL - Columbia Lighting

advertisement
VL
Vandal Resistant Wrap / 2-Lamp T5, T5HO, T8
Project Information
Project Name
Type
Catalog No.
Date
Construction
Heavy 16 gauge cold rolled steel housing with
formed end caps welded to housing.
Ballasts
Features
•
•
•
•
•
•
•
•
Ideal for high abuse areas
Effective, secure illumination mounts to ceilings or walls
Rugged heavy duty steel construction
Diffuser is .187" thick clear prismatic polycarbonate for highimpact protection
Six tamper-resistant screws for maximum security
Closed cell gasketing inhibits entry of airborne contaminants
or insects
Backpan is only 5/8" deep to hug walls or ceilings and deter
vandals
Optional stand-off mounting box permits surface conduit
entry
Finish
Painted parts are treated with a five stage
phosphate bonding process and finished with a high
reflectance baked white enamel.
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
A, unless otherwise specified. CEE NEMA Premium
compliant.
Shielding
Electrical
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
Diffuser is of 0.187" thick clear prismatic
polycarbonate material.
Certification
Ordering Information
VL
4
Model
Size
No. of Lamps
VL Vandal Resistant
Wrap
4 4'
2 Two
Example VL4-232-EU
2
–
–
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28 or 25
Watt
54 4', T5HO: 54 or 51 Watt
–
Ballast
Voltage
E Electronic T8,
Instant Start
EP Electronic T5 or T8,
Programmed Start
For a specific ballast vendor,
show as option.
Note: Certain non-standard
ballast cases may not fit the
VL. Contact factory for details.
U 120V-277V
347 347V
Options
GLR Fast Blow Fuse
WL Wet Location (Ceiling only)
EL Emergency Battery Pack T8
350-450 Lumens
EL5 Emergency Battery Pack T5
390-700 Lumens
Accessories
(Order Separately)
VLSC Surface Conduit Entry Box
VLTS Tamper Resistant Screwdriver
Note: Certain non-standard ballast cases
may not fit the VL. Contact factory for
details.
Page 1/2 Rev. 02/03/11
WRAPS / VL
© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
VL
Vandal Resistant Wrap / 2-Lamp T5, T5HO, T8
Photometric Data
Test HP06319 Test Date 3/3/09
Luminaire Data
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in Feet
Zonal Lumen Summary
Zone
VL4-232-E
Vandal Resistant Close-Fit Wrap
8" × 48" 2-Lamp with Prismatic
Plastic Lens
0.88
F32T8
2900
55
Surface
0º = 90 90º = 90
0º = 0.98 90º = 1.18
Length: 4.13
Width: 0.67
Height: 0.20
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Energy Data
Lumens % Lamp % Fixt.
765
1209
2062
2986
269
284
292
293
3279
13.2
20.9
35.5
51.5
4.6
4.9
5.0
5.1
56.5
23.3
36.9
62.9
91.1
8.2
8.7
8.9
8.9
100.0
Indoor Candela Plot
RCR
70
59
53
48
44
41
38
35
32
30
28
80
50 30
55 52
48 43
42 37
37 32
33 28
30 25
27 22
25 20
23 18
21 16
10
50
40
33
28
24
21
18
16
15
13
70
57
51
46
42
39
36
34
31
29
28
70
50 30
54 51
46 42
40 36
36 31
32 27
29 24
26 22
24 19
22 18
20 16
10
48
39
32
27
23
21
18
16
15
13
50
50
43
38
34
30
27
25
23
21
20
50
30
48
40
34
30
26
23
21
19
17
16
10
46
37
31
26
23
20
18
16
14
13
56.5%
Luminaire Efficacy Rating (LER)
IESNA RP-1-1993 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
52
Noncompliant
$4.62 based on
3000 hrs. and
$0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
Coefficients of Utilization (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
Total Luminaire Efficiency
Average Luminance Angle
Luminaire
0
0
40
32
27
23
20
17
16
14
13
11
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
4306
3041
2484
2220
2043
1992
2060
2210
2249
2151
2056
1867
4306
2966
2419
2145
1898
1702
1604
1579
1559
1604
1720
1949
4306
2998
2611
2443
2290
2129
1987
1894
1807
1773
1902
2335
4306
3175
2993
2899
2800
2741
2716
2680
2654
2722
3273
3610
4306
3326
3293
3279
3285
3347
3446
3507
3581
3789
4750
5068
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Dimensional Data
31/2"
91/2"
VL
13/8"
9"
VLSC Surface Conduit Entry Box
50"
38"
10"
65/8"
11/16"
81/2"
21/4 Dia. KO
11/16 Dia KO's (4 places)
7/8 Dia. KO's
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 02/03/11
WRAPS / VL
© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
Download