Cut Sheet - Gexpro.com

advertisement
AD
Corridor Light / 1 or 2-Lamp T5, T5HO, T8
PROJECT INFORMATION
FEATURES
t Slim design, less than 5" wide and only 4" deep
t Smooth white acrylic diffuser for soft even illumination
t White injection molded decorative plastic ends hold
diffuser in place. Easily removable for lamp access
t Heavy gauge steel die formed housing with heat sink
embossments behind ballast for cooler operation and
longer life
Project Name
Type
Catalog No.
Date
BALLASTS
SHIELDING
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
A, unless otherwise specified. CEE NEMA Premium
compliant.
100% opal acrylic extrusion.
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
FINISH
White painted parts are treated with a five stage
phosphate bonding process and finished after
fabrication with a minimum 90% reflective gloss
baked enamel.
EXAMPLE AD4-132-EU
ORDERING INFORMATION
AD
–
MODEL
LENGTH
AD Corridor
Light
2 2'
3 3'
4 4'
–
NO. OF LAMPS
1 One
2 Two
LAMP TYPE
14
17
21
24
25
28
32
2', T5: 14 Watt
2', T8: 17 Watt
3', T5: 21 Watt
2', T5HO: 24 Watt
3', T8: 25 Watt
4', T5: 28 Watt
4', T8: 32, 30, 28 or
25 Watt
39 3', T5HO: 39 Watt
54 4', T5HO: 54 or 51 Watt
–
BALLAST
E (1 or 2-Lamp) Electronic
T8, Instant Start
EP (1 or 2-Lamp) Electronic
T5 or T8, Programmed
Start
For a specific ballast vendor,
show as option.
VOLTAGE
U 120V-277V
347 347V
OPTIONS
GLR Fast Blow Fuse
EL Emergency Battery Pack
PAF Paint After Fabrication
ACCESSORIES
(ORDER SEPARATELY)
ITB4 T-Bar Hanger
S18 18" Stem, Canopy
SS18 18" Swivel Stem - 45° Swivel
Page 1/2 Rev. 02/03/11
© 2011 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
WRAPS / AD
AD
Corridor Light / 1 or 2-Lamp T5, T5HO, T8
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%)
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
0
30
40
45
50
55
60
65
70
75
80
85
Average Luminance Angle
AD4-140-E
AD Surface Mounted
48" × 47⁄8" 1-Lamp
with opal acrylic
wraparound lens
412-L-SLH-TC-P
0.95
F40CW
3150
Luminaire
45
N/A
0.0
22.5 45.0 67.5 90.0
2724
2653
2605
2562
2522
2460
2376
2267
2111
1902
1587
1205
2724 2724
2850 3138
2947 3359
2998 3490
3063 3655
3135 3845
3229 4096
3339 4426
3512 4913
3804 5706
4460 7371
6853 12727
ZONAL LUMEN SUMMARY
0º = 1.25
90º = 1.59
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Length: 4.00
Width: 0.41
Height: 0.00
Average Luminance Angle
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
349
596
1167
1824
382
462
543
556
2380
0.0
AD4-240-U
AD Surface Mounted
48" × 47⁄8" 2-Lamp
with opal acrylic
wraparound lens
446-L-SLH-TC-P
0.95
F40CW
3150
Luminaire
84
N/A
0º = 1.25
0
30
40
45
50
55
60
65
70
75
80
85
Zone
Length: 4.00
Width: 0.41
Height: 0.00
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
10
64
50
40
34
28
24
21
19
16
15
70
72
64
58
53
48
44
41
38
35
33
70
50 30
68 64
58 53
50 44
44 37
39 32
35 28
31 25
28 22
26 20
24 18
10
61
48
39
32
27
23
20
18
16
14
50
61
52
45
40
35
32
29
26
24
22
50
30
58
48
40
34
30
26
23
21
19
17
Test 8956 Test Date 1/8/03
10
56
44
36
30
25
22
19
17
15
13
0
0
44
34
28
23
20
17
15
13
11
10
INDOOR CANDELA PLOT
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
11.1
18.9
37.0
57.9
12.1
14.7
17.2
17.6
75.5
14.7
25.1
49.0
76.6
16.1
19.4
22.8
23.4
100.0
ENERGY DATA
Total Luminaire Efficiency
75.5%
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
50
Noncompliant
$4.80 based on 3000
hrs. and $0.08 per KWH
COEFFICIENTS OF UTILIZATION (%)
22.5 45.0 67.5 90.0
5047 5047
4926 5222
4841 5363
4780 5430
4697 5524
4589 5630
4437 5736
4209 5886
3934 6064
3525 6441
2948 7371
2109 10920
5047
5661
5998
6191
6423
6717
7049
7563
8290
9434
11944
20032
5047
5919
6392
6683
7025
7426
7955
8650
9710
11386
14854
26057
5047
5987
6503
6822
7199
7655
8217
8992
10132
12046
15875
28090
ZONAL LUMEN SUMMARY
90º = 1.53
80
50 30
71 67
61 55
53 46
46 39
41 34
36 29
33 26
30 23
27 21
25 19
Lumens % Lamp % Fixt.
AVG. LUMINANCE (Candela/Sq. M.)
LUMINAIRE DATA
RC
RW
1
2
3
4
5
6
7
8
9
10
70
2724
76
3357
68
3693
61
3908
56
4156
51
4463
47
4844
43
5373
40
6141
37
7405
35
9941
17999 RCR = Room Cavity Ratio
2724
3304
3616
3815
4033
4314
4673
5156
5834
6974
9298
16643
RCR
LUMINAIRE DATA
RCR
PHOTOMETRIC DATA
RC
RW
1
2
3
4
5
6
7
8
9
10
70
65
58
53
48
44
40
37
35
32
30
80
50 30
61 58
52 47
45 40
40 34
35 29
31 25
28 22
26 20
23 18
21 16
10
55
43
35
29
25
21
18
16
14
13
70
62
55
50
45
41
38
35
33
31
29
70
50 30
58 55
50 45
43 38
38 32
34 28
30 25
27 22
25 19
22 17
21 16
10
53
42
34
28
24
20
18
16
14
13
50
53
45
39
35
31
28
25
23
21
19
50
30
51
42
35
30
26
23
20
18
16
15
Test 8955 Test Date 1/8/03
10
48
38
31
26
22
19
17
15
13
12
0
0
39
31
25
21
18
15
13
12
10
9
INDOOR CANDELA PLOT
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Lumens % Lamp % Fixt.
638
1085
2093
3184
589
711
835
854
4039
10.1
17.2
33.2
50.5
9.4
11.3
13.2
13.6
64.1
15.8
26.9
51.8
78.8
14.6
17.6
20.7
21.2
100.0
ENERGY DATA
Total Luminaire Efficiency
64.1%
Luminaire Efficacy Rating (LER)
IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
46
Noncompliant
$5.22 based on 3000 hrs.
and $0.08 per KWH
DIMENSIONAL DATA
24"
17½"
36"
29½"
3¼"
J
3¼"
J
J
J
A
A
111⁄16"
12"
A
A
26½"
4¾"
47⁄8"
47⁄8"
4½"
4½"
111⁄16"
4"
4"
48"
41½"
19¼"
3¼"
J
J
A
G
A
38½"
NOTE:
4¾"
A: 7⁄8" Diameter Knockout
G: 3¼" Diameter Knockout
J: ½" Diameter × 13⁄16" Long Keyslot – dimension is to center line of mounting screw
111⁄16"
All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
MOUNTING ACCESSORIES
71⁄16"
½"
Row Mounting Detail
S18 Stem Hanger
ITB4 - Flush Mount
on T-Bar Ceiling
Page 2/2 Rev. 02/03/11
© 2011 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
WRAPS / AD
Download