Test Report - Sure Electronics

advertisement
Test Report
No. SH8087180/CHEM
Date: Jun. 21, 2008
Page 1 of 4
UNIROYAL ELECTRONICS INDUSTRY CO., LTD
21 XIAJIA NORTH ROAD, ECONOMIC & TECHNICAL DEVELOPMENT ZONE, KUNSHAN CITY, JIANGSU
PROVINCE, CHINA
The following sample(s) was/were submitted and identified by/on behalf of the client as:
Sample Name
SGS Ref No.
: METAL FILM FIXED RESISTORS
: 11104364-2
Sample Receiving Date : Jun.18, 2008
Testing Period
: Jun.18 – 21, 2008
Test Requested
: In accordance with the RoHS Directive 2002/95/EC, and its amendment directives
Test Method
: (1) With reference to IEC 62321/2nd CDV (111/95/CDV) for Cadmium content.
Analysis was performed by ICP and AAS.
(2) With reference to IEC 62321/2nd CDV (111/95/CDV) for Lead content.
Analysis was performed by ICP and AAS.
(3) With reference to IEC 62321/2nd CDV (111/95/CDV) for Mercury content.
Analysis was performed by ICP.
(4) With reference to IEC 62321/2nd CDV (111/95/CDV) for Hexavalent
Chromium by Colorimetric Method.
(5) With reference to IEC 62321/2nd CDV (111/95/CDV) for PBBs / PBDEs content.
Analysis was performed by GC/MS.
Test Results
: Please refer to next pages
Signed for and on behalf of
SGS-CSTC Chemical Laboratory
Ella Zhang
Section Manager
Signed for and on behalf of
SGS-CSTC Chemical Laboratory
Sandy Hao
Lab Manager
Test Report
No. SH8087180/CHEM
Date: Jun. 21, 2008
Page 2 of 4
Test results by chemical method (Unit: mg/kg)
Test Item(s):
Cadmium(Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (CrVI)
Sum of PBBs
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Sum of PBDEs (Note 4)
Monobromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Decabromodiphenyl ether
Sum of PBDEs (Mono to Deca)
Test Part Description:
1. Blue body with colorful part (mix all)
Method
(refer to)
(1)
(2)
(3)
(4)
(5)
1*
MDL
ND
2
RoHS
Limit
100
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
2
2
2
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
-
1000
1000
1000
1000
1000
-
Note:
(1)
(2)
(3)
(4)
(5)
(6)
mg/kg = ppm
ND = Not Detected
MDL = Method Detection Limit
Sum of Mono to NonaBDE & according to 2005/717/EC DecaBDE is exempt.
“-” = Not Regulated
The maximum permissible limit is quoted from the document 2005/618/EC amending RoHS
directive 2002/95/EC
(7) *The composite sampling method is based on the client’s special request and is a modification
from the testing standard.
Test Report
No. SH8087180/CHEM
Page 3 of 4
Date: Jun. 21, 2008
ATTACHMENTS
1) Name of the person who made measurement: Cathy Cai/George Xu/Diane Wang
2) Name of the person in charge of measurement: Terry Wang/Tracy Yue
3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr6+ and
PBBs/PBDEs test method excluded)
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Filtration
+
Cr6
PBBs/PBDEs
Sample solvent
extraction
Concentration/
Dilution of extraction
solution
Nonmetallic
material
Metallic
material
Positive
Adding extraction
solution
Spot test
Residue
Solution
Negative
Filtration
Heating to 90~95℃
for extraction
GC/MS
Filtration and pH
adjustment
Boiling water
extraction
Total digestion
DATA
ICP-AES/AAS
Adding 1,5diphenylcarbazide for
color development
Adding 1,5diphenylcarbazide
for color
development
A red color indicates
the presence of
Cr6+. If necessary,
confirm with UV-Vis.
DATA
UV-Vis
DATA
DATA
.
Test Report
No. SH8087180/CHEM
Date: Jun. 21, 2008
Sample photo:
SH8087180/CHEM
SGS authenticate the photo on original report only
*** End of Report ***