NIKE C LED - Teron Lighting

advertisement
Project:
Type:
Ordering # :
Comments:
ARCHITECTURAL INDOOR
NIKE C LED
DIMMING FEATURES
F E AT U R E S
• Die-Form Cold-Rolled Steel Housing
w/ Brushed Nickel Plated Finish
• Steel Trim w/ Brushed Nickel
Plated Finish
• Steel Mounting Pan w/ Hi-Reflectance
White Powder Coat Finish
• Luminous White Acrylic Diffuser
• Mounts Directly to 4” Junction Box
(By Others)
• Mounting Hardware Included
• 12” & 14 1/2” Housings Are
ADA Compliant
• CSA Listed Damp Location
• 120V is Energy Star Certified For
14 1/2” Nike Fixtures
• 120V 350mA Drivers Are Dimmable
• 277V 350mA Drivers Are Not Dimmable
• IES Files Are Available
• Dimmable to <5%
• Dimmable With Either Triac or
Electronic Dimmers
• Over-Current, Over-Voltage,and
Short Circuit Protection
• Constant Current at 350 Milliamps
• UL Class 2 Driver - Power Factor >.90
• Estimated 50,000 Hours Life (L70)
O R D E R I N G I N F O R M AT I O N
Example : (NEC14 - L25.0 - 120V - SM - 30K)
Brushed Nickel is Standard Finish
PRODUCT
WATTAGE/SOURCE
VOLTAGE
DRIVER OPTIONS
DIFFUSER
FINISH
Nike C 12”
(NEC12)
L12.5 - (36) LED Array
120V - 120V
277V - 277V
350mA - 350mA Constant
Current Driver
(For L12.5 & L25.0)
Not Applicable
SM - Matte Silver
TB - Textured Black
AC - Antique Copper
AS - Antique Silver
BT - Bronze Mist
CP - Copper
KC - Kenworth
Chrome
SN - Sand
SW - Swedish Steel
BZ - Textured Bronze
TW - Textured White
(50 / 60Hz)
Nike C 14 1/2”
(NEC14)
L25.0 - (72) LED Array
Nike C 17 3/4” L25.0-18H - (72) LED Array
(NEC18)
L35.0 - (72) LED Array
L37.5 - (108) LED Array
(Can be Dimmed With Either
Triac or Electronic Dimmers)
ZE12CC - 12W Line Voltage
4-Wire Dimming Driver
(For L12.5 & L25.0)
(Dimmable 0 - 10V)
ZE1050 - 1050mA Line Voltage
4-Wire Dimming Driver
(For L37.5)
(Dimmable 0 - 10V)
OPTIONS
27K - 2700K Color Temperature
30K - 3000K Color Temperature
35K - 3500K Color Temperature
40K - 4000K Color Temperature
MSI1 - Motion Sensor MSI-HFLUM2-WR
MSI2 - Motion Sensor MSI-FM105
120/277V
MIV - 20 Watt Micro-Inverter (Remote)
TP - Tamper-Proof Screw Set
F - Fused
See Pg. 2 For Wattage
Specifications
RAL Colors or
Custom Match Consult Factory
TE500 - 500mA ELV Low Voltage
2-Wire Electronic Driver
(For L35.0)
(Can be Dimmed With Either
Triac or Electronic Dimmers)
R E P L A C E M E N T PA R T S
12” White Acrylic Diffuser
14” White Acrylic Diffuser
18” White Acrylic Diffuser
PA R T N O .
3035960
3049660
3049760
NOTES
We reserve the right to revise the design or components of any product due to
parts availability or change in UL standards, without assuming any obligation or
liability to modify any products previously manufactured, and without notice.
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:sales@teronlight.com
web:teronlight.com
Project:
Type:
Ordering # :
Comments:
PRODUCT
Nike C
12”
Housing
SOURCE/WATTAGE
L12.5 - (36) LED Array
- Constant Current @350mA
- 12.5 Input Watts
50,000 Hours(L70)
Nike C
14 1/2”
Housing
L25.0 - (72) LED Array
- Constant Current @350mA
- 25.0 Input Watts
50,000 Hours(L70)
Nike C
17 3/4”
Housing
L37.5 - (108) LED Array
- Constant Current @350mA
- 37.5 Input Watts
50,000 Hours(L70)
27K SPECIFICATIONS
30K SPECIFICATIONS
35K SPECIFICATIONS
40K SPECIFICATIONS
12.5W LED ARRAY
27K - 2700K Color Temp.
12.5W LED ARRAY
30K - 3000K Color Temp.
12.5W LED ARRAY
35K - 3500K Color Temp.
12.5W LED ARRAY
40K - 4000K Color Temp.
- 80 CRI Typ.
- 1046 LED Lumens
(719 Fixture Lumens)
- Estimated 58 Lumens Per Watt
- 80 CRI Typ.
- 1090 LED Lumens
(749 Fixture Lumens)
- Estimated 60 Lumens Per Watt
- 80 CRI Typ.
- 1124 LED Lumens
(772 Fixture Lumens)
- Estimated 62 Lumens Per Watt
- 80 CRI Typ.
- 1133 LED Lumens
(778 Fixture Lumens)
- Estimated 62 Lumens Per Watt
25.0W LED ARRAY
27K - 2700K Color Temp.
- 80 CRI Typ.
- 2078 LED Lumens
(1421 Fixture Lumens)
- Estimated 57 Lumens Per Watt
25.0W LED ARRAY
30K - 3000K Color Temp.
- 80 CRI Typ.
- 2165 LED Lumens
(1480 Fixture Lumens)
- Estimated 59 Lumens Per Watt
25.0W LED ARRAY
35K - 3500K Color Temp.
- 80 CRI Typ.
- 2233 LED Lumens
(1526 Fixture Lumens)
- Estimated 61 Lumens Per Watt
25.0W LED ARRAY
40K - 4000K Color Temp.
- 80 CRI Typ.
- 2250 LED Lumens
(1538 Fixture Lumens)
- Estimated 62 Lumens Per Watt
37.5W LED ARRAY
27K - 2700K Color Temp.
- 80 CRI Typ.
- 3442 LED Lumens
(2160 Fixture Lumens)
- Estimated 58 Lumens Per Watt
37.5W LED ARRAY
30K - 3000K Color Temp.
- 80 CRI Typ.
- 3585 LED Lumens
(2250 Fixture Lumens)
- Estimated 60 Lumens Per Watt
37.5W LED ARRAY
35K - 3500K Color Temp.
- 80 CRI Typ.
- 3693 LED Lumens
(2318 Fixture Lumens)
- Estimated 62 Lumens Per Watt
37.5W LED ARRAY
40K - 4000K Color Temp.
- 80 CRI Typ.
- 3764 LED Lumens
(2363 Fixture Lumens)
- Estimated 63 Lumens Per Watt
33 Donald Drive Fairfield, OH 45014
ph:(513)858-6004
fax:(513)858-6038
email:sales@teronlight.com
web:teronlight.com
HFLUM2-WR
Fixture Integrated Sensor Module
Project Name:
Location:
HF LUM2-WR Specifications
Item No.
Voltage
Load Rating
Transmitter Power
Power Consumption
65122
120/230/277 VAC, 50/60 Hz
0-800 watts @ 120 VAC, 50/60 Hz incandescent, magnetic or electronic ballasts - 1/4 HP
0-1200 watts @ 230/277 VAC, 50/60 Hz magnetic or
electronic ballasts
0-650 watts @ 120/230/277 VAC, 50/60 Hz LED
1 mW
< 0.5 W
Time Delay Setting
30 seconds to 30 minutes
Light Level Setting
0.2-200 footcandles
2-2000 lux
HF System
Coverage
Environment
5.8 GHz
360° adjustable 3.3 to 26 ft reach (1 to 8 m)
requires enclosure
temperature -4° F - 185° F, -20° C - 85° C
Dimensions 4.2 x 1.7 x 1.8 in
(LxWxD) 107 x 42 x 44.5 mm
Warranty
Certifications
The HFLUM2-WR is a line voltage occupancy sensor module
that installs in a fixture, adding energy saving lighting control
in each fixture location. The HFLUM2-WR uses STEINEL’s High Frequency (HF)
technology to turn lights on and off based on occupancy.
It works by emitting high frequency electromagnetic waves
(5.8 GHz) into the controlled area. Movement in the area
causes a change in the waves’ echo, resulting in occupancy detection. The sensor can detect motion through many
materials including glass and the lens of a fixture, enabling
the sensor to be hidden from view.
5 years
C-UL-US Listed, RoHS Compliant,
Contains: FCC ID - W8J-SIR13, IC - 8529A-SIR13
Key Features:
•
•
•
•
•
•
•
360° coverage; reach is adjustable from 3.3 to 26 ft
High frequency technology emits 5.8 GHz electromagnetic
waves
Built-in surge protection with auto-reset
Lamp seasoning feature provides a simple and convenient 4
day burn in as recommended by lamp manufacturers
Adjustable time delay and light level settings
Light level feature allows lighting to remain off during daylight,
regardless of occupancy (hold off)
Wiring is streamlined with three terminals
Applications
Mounted in either a ceiling or wall lighting fixture, the sensor
module is suited to a wide variety of interior spaces including
offices, conference rooms and damp or wet locations when
mounted inside sealed and gasketed fluorescent IP65 type
fixtures.
Line Voltage
High Frequency Technology
360˚ of Coverage
Fixture Integrated
0.2 - 200 fc
www.steinel.net
HF LUM2-WR
Fixture Integrated Sensor Module
Controls
Photocell
Sensitivity
Sensor dome
Time delay
antenna
Light Level
Wire
terminations
Mounting
tabs
Mounting
Coverage
3.3 - 13 ft
1-4m
44.5 mm
1.75”
Typical mounting
height is 8 to 10 ft
Mounting screw
holes are 3.8 inches
(97 mm) apart
107 mm
4.2”
97 mm
3.8”
3.3 - 26 ft
1-8m
Wiring
Coverage Adjustments
Sensitivity:
Adjusts coverage reach
from approximately 3.3
feet to 26 feet
42 mm
1.65”
3.3 - 16.4 ft
ca. 1 - 5 m
Time delay:
30 seconds to
30 minutes
Light level:
.2 (night) to 200
(day) footcandles
NEUTRAL
HOT
LOAD
www.steinel.net
(800) 852-4343
9051 Lyndale Avenue South, Bloomington, MN 55420
M-04105-1
FIXTURE SENSORS & CONTROLS
FM-105 Super High Frequency Occupancy Sensor
Mounting bracket for
flexible installation
Adjustable time delay
Line voltage occupancy sensor
Adjustable detection sensitivity
Mounts behind fixture
lens hidden from view
Hold-off daylighting control
PROJECT
LOCATION/TYPE
Product
Overview
Description
Flexible Functionality
The FM-105 Super High Frequency Occupancy
Sensor is a line voltage sensor that turns lighting
on and off based on occupancy, and can hold
lights off when sufficient daylight is available. It
detects motion via super high frequency (SHF)
electromagnetic waves and the Doppler principle.
Because it can detect motion through many dense
materials other than metal, the FM-105 can be
installed behind fixture lenses and hidden from
view.
The FM-105 Sensor coverage pattern is
omnidirectional. Depending on its installation, it
can be adjusted to detect occupancy up to 20 feet
away. The FM-105 can be placed inside a lighting
fixture or behind an object made of wood or plastic
so that it is completely hidden from direct view. Its
integrated daylight sensitivity adjusts from 2 to 200
footcandles, and its time delay may be set from 10
seconds to 30 minutes.
Applications
Operation
The FM-105 operates at 120 or 277 VAC and
utilizes SHF technology to control lighting based
on occupancy. It sends out electromagnetic waves
that bounce off nearby surfaces, and uses the
Doppler principle to analyze changes in the return
waves to detect motion in the area (similar to the
way that ultrasonic sensor technology performs).
When motion is detected, the FM-105 turns on the
load, unless the ambient light level is greater than
the daylighting setpoint (if enabled), or turns off the
load when no motion is detected for the preset time
delay.
Features
• Detects movement when installed behind lowdensity fixture materials, such as polycarbonate,
acrylic and glass diffusers
• Provides hold-off daylighting control when
ambient light is greater than daylighting setpoint
www.wattstopper.com
800.879.8585
The FM-105 operates best when installed
behind low-density fixture materials, such as
polycarbonate, acrylic and glass diffusers. FM-105
technology also provides superior detection in hard
surfaced areas such as stairwells and hallways.
This sensor is also suited for installation behind
lenses in outdoor wall sconces, wall packs and
pedestrian-scale luminaires.
• Mounting bracket facilitates installation in
various mounting positions
• Simple line voltage wiring does not require a
power pack
• Can be mounted hidden from view
• Time delay adjustable from 10 seconds to 30
minutes
• Easy adjustment via trimpots
• Adjustable sensitivity range up to 20 feet
• RoHS compliant
Mounting
30 min
-
+
1
200
Sensitivity
CONTROL
FCC ID: Q4BFM105
88T9
APPLIANCE
FM-105
Microwave (5.8 GHz)
GHz)
Occupancy Sensor
FM-105
Time Delay
120/277VAC, 50/60
50/60 Hz
Hz
100-277VAC,
@120VAC:0-600W
0-800WBallast,
Ballast
@120VAC:
orTungsten,
Tungsten
0-600W
Light Level
(footcandles) @277VAC: 0-1200W 1/6
Ballast
hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
10
sec
30 min
-
+
1
200
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Microwave (5.8 GHz)
Occupancy Sensor
100-277VAC, 50/60 Hz
120/277VAC,
@120VAC:
@120VAC: 0-600W
0-800WBallast,
Ballast
0-600W
orTungsten,
Tungsten
Light Level
(footcandles) @277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
Sensitivity
LINE
10
sec
NEUT
1
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Time Delay
Sensitivity
LOAD
100-277VAC, 50/60
50/60 Hz
Hz
120/277VAC,
@120VAC: 0-600W
0-800W Ballast,
Ballast
0-600W
or Tungsten,
Tungsten
Light Level
1/6 hp
200 (footcandles) @277VAC: 0-1200W Ballast
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
+
LOAD
NEUT
200
FM-105
Microwave (5.8
(5.8 GHz)
GHz)
Microwave
Occupancy Sensor
Sensor
Occupancy
30 min
-
LINE
Time Delay
10
sec
NEUT
FM-105
Microwave (5.8 GHz)
Occupancy Sensor
120/277VAC, 50/60 Hz
100-277VAC,
@120VAC:0-600W
0-800WBallast,
Ballast
@120VAC:
orTungsten,
Tungsten
0-600W
Light Level
(footcandles) @277VAC: 0-1200W 1/6
Ballast
hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
LOAD
1
Sensitivity
LOAD
+
LINE
30 min
-
NEUT
Time Delay
10
sec
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
Mounting foot provides four different mounting positions.
Wiring Diagram
Plastic mounting foot
FM-105
Time Delay
Time Delay
10
sec
30 min
-
+
1
200
FM-105
Microwave (5.8 GHz)
Occupancy Sensor
30 min
-
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
Light Level
200 (footcandles) @277VAC: 0-1200W Ballast
1
100-277VAC, 50/60 Hz
120/277VAC,
@120VAC:
@120VAC:0-600W
0-800WBallast,
Ballast
0-600W
orTungsten,
Tungsten
Light Level
1/6 hp
(footcandles) @277VAC: 0-1200W Ballast
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
Microwave (5.8 GHz)
Occupancy Sensor
10
sec
+
Sensitivity
LINE
NEUT
LOAD
Sensitivity
APPLIANCE
CONTROL
FCC ID: Q4BFM105
88T9
LINE
NEUT
Metal
shield
LOAD
FCC ID: Q4BFM105
Lighting
Load
APPLIANCE
CONTROL
88T9
Hot/Line
Neutral
Position metal shield between FM-105 and lamp/ballast.
Coverage
Wall Mount
Ceiling Mount
18’ (5.5m)
18’ (5.5m)
12’ (4m)
12’ (4m)
Installed
FM-105
inside a ceiling
inside
ceiling
mount
mounted
fixture
lighting fixture
at
at8’a (2.5m)
height of 8’
height
6’ (2m)
6’ (2m)
MIN.
3’ (1m)
MAX.
20’ (6m)
Installed
inside a wall
mounted
lighting
fixture at a
height of 5’
(1.52m)
(2.44m)
MAX.
MIN.
Coverage pattern will vary based on installation of sensor and surrounding materials.
Ordering
Information
Pub. No. 29300 rev. 10/2009
Catalog No.
FM-105
Description
Super High Frequency Occupancy Sensor
Voltage
Load Capacity
120 VAC
0-800 W ballast or tungsten
277 VAC
0-1200 W ballast
www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5
FIXTURE SENSORS & CONTROLS
Mounting &
Wiring
• Dimensions: 2.0” x 3.09” x 1.63” (51.0mm x
78.5mm x 41.4mm) L x W x D
• Weight: 2.3 oz (65.2 g)
• Operating temperature range: -4-131°F
(-20-55°C)
• FCC approved
• UL and CUL listed
• Five year warranty
• 120/277 VAC, 50/60 Hz
• Load requirements
@ 120 VAC, 60 Hz: 0-800 W ballast or tungsten
@ 277 VAC, 60 Hz: 0-1200 W ballast
• Light Level: 2-200 fc
• Range/Sensitivity: Up to 20’ (6.1m)
• Time delay: 10 seconds to 30 minutes
• Operating frequency: 5.8 GHz
• Power output: 1 mW
LINE
Specifications
Download