Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
Neo-Ray's development of the recessed asymmetric 7VCR luminaire
represents the latest technology in precise light distribution and control for
video conferencing environments. The 7VCR's well-shielded yet wide soft
asymmetric light distribution illuminates the subjects without a hint of
brightness in the video camera's field of view or light spillage on the main
presentation screen. The efficient design and well-controlled light
distribution of the 7VCR requires fewer fixtures than current types for
comparable lighting results. Quality fit and finish and value are maintained
to provide the best performance and the most cost- effective solution for
your video conferencing spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-gauge steel housing.
B ... Shielding
.75" high blade baffle 3" oc. with
prismatic clear acrylic overlay.
C ... Electrical
120, 277, 347 or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards. Note:
Fifthlight is not available for Biax
lamps.
D ... Finish
Durable, charcoal gray, powder
coated acrylic finish. Custom
colors available.
Mounting
Recessed.
12-5/8" [321mm]
11-3/8" [289mm]
7VCR
7-VCR
6-5/8"
[168mm]
1 & 2T5
1 & 2T5HO
1 BX40W
1BX50W
6"
[152mm]
Specialty
Direct-Asymmetric
Recessed
Video Conference
12" [305mm]
TIE WIRES (NOT SUPPLIED BY NEO-RAY)
7VC2R
22.000" HOUSING WIDTH
Light Distribution:
Indirect - 0.0%
Direct - 100.0%
6"
HOUSING
HEIGHT
(DIRECTION OF LIGHT)
(DIRECTION OF LIGHT)
9 29/32" x 23" FIXTURE OPENING
9 29/32" x 23" FIXTURE OPENING
23.5" FIXT. SIZE
24"X24" CEN.-TO-CEN.
ORDERING INFORMATION
Sample Number: 7VCR-12-1BX40W-ETG-48-1EB-SI-S62A
Series
7VC=Specialty
Mounting
R=Recessed
Fixture Size
12=1'x2'
Number of Lamps
14=1'x4'
22=2'x2'
1=1 Lamp
2=2 Lamps (T5, T5HO)
(Not included)
Lamp Type
T5
T5HO
BX40W
BX50W
Notes: 1
2
Ceiling Type
ETG=15/16" Exposed
T-Grid
STG=Slot T-Grid
SR=Sheet Rock 1
(Flanged)
Voltage
1=120V
2
2=277V
3=347V
U=Universal
Ballast
EB=Electronic Ballast
(Standard)
Shielding
S62A=Lateral Aluminum Baffle
DB=Dimming Ballast
Emergency
EM=Emergency
Pack (Consult
Factory)
Fusing
GLR
GMF
Fixture must be installed before gyp board ceiling.
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041946
09/18/2013 11:20:26 PM
PHOTOMETRICS
Neoray 7-VCR
180
135
Coefficients of Utilization
rc
rw
90
90
45
0
45
0
Effective floor cavity reflectance
80%
50%
70
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
50 30
10
Angle
0
Along II
1221
45°
1221
Across ⊥
1221
50 30 10
5
1551
1378
1169
10
15
1773
1863
1513
1590
1143
1082
20
25
30
35
40
45
50
55
60
1929
1932
1953
1978
1989
2042
1965
1876
1429
1638
1616
1566
1488
1418
1387
1246
1103
827
973
885
753
637
486
328
216
138
101
65
70
75
852
432
154
550
278
105
68
32
9
80
85
90
48
6
0
34
0
0
0
0
0
Angle
0
5
10
15
Along II
1302
1557
1795
1874
45°
1302
1470
1626
1698
Across ⊥
1302
1275
1236
1154
20
1945
1762
1078
25
30
35
40
45
1974
1988
2018
2042
2064
1746
1692
1588
1529
1516
968
842
706
552
370
50
55
60
65
1940
1837
1428
865
1347
1190
865
581
244
159
112
77
70
75
80
85
90
433
154
49
6
0
303
114
40
0
0
38
15
0
0
0
20%
30%
50 30 10
51
51 51 51
48 48 48
46 46 46
48
45
41
38
35
32
30
27
25
23
46
42
37
33
30
27
24
22
19
18
44
39
36
32
29
26
23
21
19
17
42
38
34
31
28
25
23
20
18
17
45
39
34
30
26
23
21
18
16
14
44
37
32
28
24
21
18
16
14
12
43
38
33
29
26
23
20
18
16
14
42
36
31
27
23
21
18
16
14
12
41
37
32
29
25
22
20
18
15
14
40
35
31
27
23
20
18
16
14
12
Zonal Lumen Summary
7VCR-BX40W
(1) FT40W/2G11/RS/35
3150 Lumens
Efficiency 43.2%
Test Report
#10667.0
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
889
1402
14.1
22.3
32.7
51.6
0-60
0-90
2421
2719
38.4
43.2
89.0
100.0
0-180
2719
43.2
100.0
PHOTOMETRICS
180
135
Coefficients of Utilization
Candela
Effective floor cavity reflectance
rc
rw
RCR
0
1
90
90
0
7VCR-BX50W
(1) FT50W/2G11/RS/35
4000 Lumens
Efficiency 36.4%
Test Report
#10669.0
45
0
45
2
3
4
5
6
7
8
9
10
70
80%
50 30
43
40
38
35
43
39
35
32
32
29
27
25
23
21
28
25
23
20
18
16
20
15 12 10
20%
10
50%
50 30 10
30%
50 30 10
43
38
33
29
43
37
31
27
40
37
33
30
40
36
32
28
40
35
30
26
39
35
32
29
39
35
31
27
39
34
30
26
25
22
20
17
15
13
23
20
18
15
13
12
27
24
22
20
18
16
25
22
19
17
15
13
23
20
17
15
13
11
26
23
21
19
17
15
24
21
19
17
15
13
23
20
17
15
13
11
14 12 10
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
950
1498
2591
11.9
18.7
32.4
32.6
51.5
89.0
0-90
0-180
2911
2911
36.4
36.4
100.0
100.0
14 12 10
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041946
09/18/2013 11:20:26 PM
PHOTOMETRICS
180
135
Coefficients of Utilization
Candela
Effective floor cavity reflectance
rc
rw
70
80%
50 30
20%
50%
50 30 10
10
30%
50 30 10
RCR
90
90
0
7VCR-2T5HO
(2) FP54T5/835
5000 Lumens
Efficiency 41.9%
Test Report
#10665.0
45
0
45
0
1
2
3
4
5
6
7
8
9
10
50
50 50 50
47 47 47
45 45 45
47
43
40
37
34
31
29
26
24
23
45
40
36
33
29
26
23
21
19
17
42
38
35
31
28
25
23
20
18
16
41
37
33
30
27
24
22
20
18
16
44
38
33
29
26
23
20
18
16
14
42
36
31
27
23
20
18
15
13
12
41
37
32
28
25
22
20
17
15
14
40
35
30
26
23
20
17
15
13
12
40
36
32
28
25
22
19
17
15
12
39
34
30
26
23
20
17
15
13
12
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
1362
13.6
32.5
0-40
0-60
0-90
2156
3752
4193
21.6
37.5
41.9
51.4
89.5
100.0
0-180
4193
41.9
100.0
Angle
0
Along II
1829
45°
1829
Across ⊥
1829
5
2221
2087
1780
10
2494
2331
1720
15
20
25
30
35
40
45
50
55
2673
2787
2824
2848
2901
2996
3020
2819
2602
2499
2523
2509
2448
2294
2225
2131
1977
1736
1570
1496
1335
1170
970
764
532
347
234
60
65
70
1824
1096
541
1226
842
431
166
112
61
75
80
85
90
185
60
9
0
166
56
0
0
0
0
0
0
MOUNTING INFORMATION
ETG
EXPOSED TEE GRID
STG
SLOT TEE GRID
SR
SHEET ROCK
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041946
09/18/2013 11:20:26 PM
Download