Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay FEATURES/BENEFITS • Latest generation MOSFET technology • Ultra low on-state resistance • Innovative isolated driver ensures fast power transistor turn on and off and thus low power transient • Ultra low output leakage current • Low control current consumption • Triggered control input to avoid linear control risks • Low conducted and radiated disturbances Part Number Description MECHANICAL SPECIFICATION S60DC40 40A, 600 Vdc Solid-State Relay 1.10 (28) .089(22.8) ±.02 Ø0.5 0.89 (22.8) Part Number Explanation DC 40 2.29 (58.2) Switch Type2 Line Voltage Output Current – Amps Series 1 NOTES 1) Line Voltage (peak): 60 = 600 Vdc 2) Switch Type: DC = DC 1+ 2– 4– 3+ 1.87 (47.6) 60 M5 1.7 (43.2) S 1.10 (28) ø0.19(ø 4.7) Ø4.7 0.77 (19.6) 1.01 (25.8) Max Units Control Range 4.5 32 Vdc Input Current Range 25 42 mAdc Typical Turn-On Voltage 4.3 Vdc 1 Vdc Reverse Voltage 32 Vdc Reverse Leakage Current 100 μA CONTROL CHARACTERISTIC Figure 1 BLOCK DIAGRAM +3 CONTROL Control Current (mAdc) 40 35 Driver (OFF) Single pulse turn LED ON & OFF @25°C circuit 1+ MOSFET PHV |Scst 25 M3 Tolerances: ±.001 Ø0.3 Dimensions in inches (mm) Weight: 3.52 oz. (100g) 45 30 1.0 (25.4) 1.75 (44.5) OUTPUT Min Must Turn-Off Voltage 0.29 (7.5) INPUT (CONTROL) SPECIFICATIONS 0.20 (5.1) ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) 2– –4 20 Figure 3 15 10 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Control Voltage (V) Figure 2 © 2016 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S60DC40 Page 1 S60DC40\012016\Q1 Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) DC Control Power Supply OUTPUT (LOAD) SPECIFICATIONS Operating Range DC Mains Min Max 0 350* Vdc 600 Vpeak Peak Voltage Reverse Voltage (Internal Diode) 1.2 HIGH SIDE WIRING DIAGRAM (Load Connected to “—”) Units 20 A Vc (Red paths as short as possible) Ic D2 2- 1800 C1 D1 or Vt 3+ Maximum Single Pulse Avalanche Energy or On-Off Control mJ or Maximum Repetitive Pulse Avalanche Energy 1 mJ Maximum Nominal Currents (Resistive) 40 A Non-Repetitive Peak Overload Current 140 A Leakage Current 250 μAdc On-State Resistance 70 mΩ Output Capacitance (Typical) 2.2 Load Figure 4 LOW SIDE WIRING DIAGRAM (Load Connected to “+”) DC Control Power Supply nF DC Mains °C/W 8 °C/W Ie Ve On-Off Control C1 2- Heat Sink Thermal Time Constant Control Inputs/Power Outputs Insulation Voltage min D1 or D2 4 kV or Turn-On Time 10 μs or Turn-On Delay 600 μs Turn-Off Time 10 μs Turn-Off Delay 100 μs On-Off Frequency 700 Hz *Recommend 275 Vrms size 20 varistor as protection across the output. Ic Vt 1+ 10 3+ Built-In Heat Sink Thermal Resistance (Vertically Mounted) 0.4 Vc (Red paths as short as possible) 4- Junction-Case Thermal Resistance S60DC40 Page 2 1+ 4- Maximum Repetitive Avalanche Current Ve Ie V Load Figure 5 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS S60DC40\012016\Q1 Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay GENERAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) TIME DIAGRAMS TURN-ON ENVIRONMENTAL SPECIFICATIONS Min Vc (control) t Vt (switch) t tdon ton Units Operating Temperature –40 +90 °C Storage Temperature –55 +100 °C Input-Output Isolation 4000 Vrms Insulation Resistance 1 GΩ Insulation Capacitance 8 pF Junction Temperature TURN-OFF 150 °C CONNECTIONS Power Vc (control) Screwdriver t 1.8 N.m 0.8 N.m M5 M3 Insulated crimp terminals (Round Tabs, Eyelet Type) t Control Phillips NR2 Phillips NR1 Tightening Torque Vt (switch) tdoff Max toff MISCELLANEOUS Figure 6 Display Housing ON RESISTANCE VS. TEMPERATURE 200 RDSon (mOhms) Green LED (ON) UL94V0 Mounting 2 screws (M4x12mm) Noise Level No audible noise GENERAL 160 Standards 120 80 IEC60947-1 Protection Level IP00 Protection Against Direct Touch None CE Marking Yes UL, cULUS & VDE Approvals 40 Pending 0 –50 0 50 100 Junction Temperature (°C) Figure 7 © 2016 TELEDYNE RELAYS E.M.C. EMISSION 150 Radiated & Conducted Disturbances NFEN55011 (800) 284-7007 • www.teledynerelays.com S60DC40 Page 3 S60DC40\012016\Q1 Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay POWER DISSIPATION AND LOAD CURRENT LIMIT VS. TEMPERATURE Please refer to the installation notice for precautions about mounting the device on a heat sink. 45 284 1.2°C/W 1.1°C/W 0.9°C/W 0.75°C/W 0.55°C/W 0.3°C/W 0.2°C/W 0.1°C/W 40 224 35 172 30 126 25 87.5 20 56 15 31.5 10 14 5 Power Dissipation (W) Load Current (Arms) 1.3°C/W 3.5 8°C/W 4°C/W 2.4°C/W 2.2°C/W 2.1°C/W 1.95°C/W 1.5°C/W 0 0 10 20 30 40 50 60 70 80 90 0 110 100 Ambient Temperature (°C) Figure 8 PROTECTIVE COVER AVAILABLE Add -14 to part number Apeak CURRENT OVERLOAD CHARACTERISTICS Figure 9 NOTES 1. For additional/custom options, contact factory. 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Non-repetitive peak overload switching current vs. overvoltage protection clamping voltage (D1) Single pulse F(on-off)=50Hz F(on-off)=100Hz F(on-off)=700Hz 0 100 200 300 400 500 600 Vtpk (V) 140 Non-repetitive on-state (no switching) max. peak current vs. overload pulse duration 120 APeak 100 80 60 40 20 0 0.1 1 10 100 1000 t(ms) Figure 10 S60DC40 Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2016 TELEDYNE RELAYS S60DC40\012016\Q1 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Teledyne Relays: S60DC40