NEW Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay FEATURES/BENEFITS • Latest generation MOSFET technology • Ultra low on-state resistance • Innovative isolated driver ensures fast power transistor turn on and off and thus low power transient • Ultra low output leakage current • Low control current consumption • Triggered control input to avoid linear control risks • Low conducted and radiated disturbances Part Number Description S60DC40 40A, 600 Vdc Solid-State Relay MECHANICAL SPECIFICATION 1.10 (28) 0.89 (22.8) Ø0.5 Part Number Explanation 40 Switch Type2 Line Voltage1 Output Current – Amps 2.29 (58.2) Series DC M5 NOTES 1) Line Voltage (peak): 60 = 600 Vdc 2) Switch Type: DC = DC 1+ 2– 4– 3+ 1.87 (47.6) 60 Ø4.7 1.7 (43.2) S 1.10 (28) 0.77 (19.6) 1.01 (25.8) Min Max Units Control Range 4.5 32 Vdc Input Current Range 25 42 mAdc Typical Turn-On Voltage 4.3 Vdc Must Turn-Off Voltage1 Vdc Reverse Voltage 32 Vdc Reverse Leakage Current100 µA CONTROL CHARACTERISTIC Figure 1 BLOCK DIAGRAM +3 CONTROL 40 35 @25°C Driver (OFF) Single pulse turn LED ON & OFF circuit 1+ MOSFET PHV |Scst 25 M3 Tolerances: Ø0.3 Dimensions in inches (mm) Weight: 3.52 oz. (100g) 45 30 1.0 (25.4) 1.75 (44.5) OUTPUT Control Current (mAdc) 0.29 (7.5) INPUT (CONTROL) SPECIFICATIONS 0.20 (5.1) ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) 2– –4 20 Figure 3 15 10 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Control Voltage (V) Figure 2 © 2006 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S60DC40 Page S60DC40\102006\Q1 NEW Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay HIGH SIDE WIRING DIAGRAM (Load Connected to “—”) ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) DC Control Power Supply OUTPUT (LOAD) SPECIFICATIONS Min Max 0 350* Vdc Peak Voltage 600 Vpeak Operating Range 4- Maximum Repetitive Avalanche Current 20 Maximum Nominal Currents (Resistive) 40 Non-Repetitive Peak Overload Current140 Ic Vc or On-Off Control mJ (Red paths as short as possible) D2 2- Maximum Repetitive Pulse Avalanche Energy1 A C1 D1 or Vt 3+ Maximum Single Pulse Avalanche Energy1800 Ve Ie V 1+ Reverse Voltage (Internal Diode)1.2 DC Mains Units or mJ Load A A Figure 4 Leakage Current 250 µAdc On-State Resistance 70 mΩ LOW SIDE WIRING DIAGRAM (Load Connected to “+”) nF 0.4 °C/W Built-In Heat Sink Thermal Resistance (Vertically Mounted) 8 °C/W Ie Ve Control Inputs/Power Outputs Insulation Voltage 4 kV or Turn-On Time10 µs or Turn-On Delay 600 µs Turn-Off Time10 µs Turn-Off Delay100 µs 2- min On-Off Frequency D1 or D2 Ic Vt Vc (Red paths as short as possible) Load 700Hz *Recommend 275 Vrms size 20 varistor as protection across the output. S60DC40 Page On-Off Control C1 Heat Sink Thermal Time Constant10 3+ Junction-Case Thermal Resistance DC Control Power Supply DC Mains 4- 2.2 1+ Output Capacitance (Typical) Figure 5 Specifications are subject to change without notice © 2006 TELEDYNE RELAYS S60DC40\102006\Q1 NEW Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay TIME DIAGRAMS GENERAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) TURN-ON ENVIRONMENTAL SPECIFICATIONS Vc (control) t Vt (switch) t tdon Max Units –40 +90 °C –40 +100 °C Min Operating Temperature Storage Temperature Input-Output Isolation 4000 Vrms Insulation Resistance1GΩ ton Insulation Capacitance 8 pF Junction Temperature150 TURN-OFF CONNECTIONS Vc (control) t Control Phillips NR2 Phillips NR1 Tightening Torque1.8 N.m Insulated crimp terminals (Round Tabs, Eyelet Type) t 0.8 N.m M5 M3 toff MISCELLANEOUS Figure 6 DisplayGreen LED (ON) Housing ON RESISTANCE VS. TEMPERATURE UL94V0 Mounting2 screws (M4x12mm) Noise LevelNo audible noise 200 RDSon (mOhms) Power Screwdriver Vt (switch) tdoff °C GENERAL 160 120 80 40 Standards IEC60947-1 Protection Level IP00 Protection Against Direct Touch None CE Marking Yes UL, cULUS & VDE Approvals Pending 0 –50 0 50 100 Junction Temperature (°C) E.M.C. EMISSION 150 Radiated & Conducted Disturbances NFEN55011 Figure 7 © 2006 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S60DC40 Page S60DC40\102006\Q1 NEW Series S60DC40 Output to 40A, 600 Vdc DC Solid-State Relay POWER DISSIPATION AND LOAD CURRENT LIMIT VS. TEMPERATURE Please refer to the installation notice for precautions about mounting the device on a heat sink. 45 284 1.2°C/W 1.1°C/W 0.9°C/W 0.75°C/W 0.55°C/W 0.3°C/W 0.2°C/W 0.1°C/W 40 224 35 172 30 126 25 87.5 20 56 15 31.5 10 14 5 Power Dissipation (W) Load Current (Arms) 1.3°C/W 3.5 8°C/W 4°C/W 2.4°C/W 2.2°C/W 2.1°C/W 1.95°C/W 1.5°C/W 0 0 10 20 30 40 50 60 70 80 90 0 110 100 Ambient Temperature (°C) Figure 8 CURRENT OVERLOAD CHARACTERISTICS Apeak PROTECTIVE COVER AVAILABLE Add -14 to part number Figure 9 NOTES 1. For additional/custom options, contact factory. 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Non-repetitive peak overload switching current vs. overvoltage protection clamping voltage (D1) Single pulse F(on-off)=50Hz F(on-off)=100Hz F(on-off)=700Hz 0 100 200 300 400 500 600 Vtpk (V) 140 Non-repetitive on-state (no switching) max. peak current vs. overload pulse duration 120 APeak 100 80 60 40 20 0 0.1 1 10 100 1000 t(ms) Figure 10 S60DC40 Page Specifications are subject to change without notice © 2006 TELEDYNE RELAYS S60DC40\102006\Q1