NEW Series S20DC100 Output to 100A, 200 Vdc DC Solid-State Relay FEATURES/BENEFITS • Latest generation MOSFET technology • Ultra low on-state resistance • Innovative isolated driver ensures fast power transistor turn on and off and thus low power transient • Ultra low output leakage current • Low control current consumption • Triggered control input to avoid linear control risks • Low conducted and radiated disturbances Part Number Description S20DC100 100A, 200 Vdc Solid-State Relay MECHANICAL SPECIFICATION 1.10 (28) 0.89 (22.8) Ø0.5 Part Number Explanation 100 Switch Type2 Line Voltage1 Output Current – Amps 2.29 (58.2) Series DC M5 NOTES 1) Line Voltage (peak): 20 = 200 Vdc 2) Switch Type: DC = DC 1+ 2– 4– 3+ 1.87 (47.6) 20 Ø4.7 1.7 (43.2) S 1.10 (28) 0.77 (19.6) 1.01 (25.8) Min Max Units Control Range 4.5 32 Vdc Input Current Range 25 42 mAdc Typical Turn-On Voltage 4.3 Vdc 1 Vdc Must Turn-Off Voltage 0.29 (7.5) INPUT (CONTROL) SPECIFICATIONS Reverse Voltage 32 Vdc Reverse Leakage Current 100 µA 0.20 (5.1) ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) 1.0 (25.4) M3 1.75 (44.5) Tolerances: Ø0.3 Dimensions in inches (mm) weight: 3.52 oz. (100g) Figure 1 BLOCK DIAGRAM CONTROL CHARACTERISTIC +3 35 @25°C 30 25 Driver (OFF) Single pulse turn ON & OFF circuit LED 20 1+ MOSFET PhV IScst OUTPUT 40 CONTROL Control Current (mAdc) 45 2+ –4 15 10 Figure 3 5 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Control Voltage (V) Figure 2 © 2006 TELEDYNE RELAYS S20DC100 Page S20DC100\062006\Q1 NEW Series S20DC100 Output to 100A, 200 Vdc DC Solid-State Relay ELECTRICAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) OUTPUT (LOAD) SPECIFICATIONS Min Max 0 130 Vdc Peak Voltage 200 Vpeak Maximum Repetitive Avalanche Current 100 A Maximum Single Pulse Avalanche Energy 3+ mJ A Non-Repetitive Peak Overload Current 400 A Leakage Current 250 µAdc On-State Resistance 22 mΩ 1.5 or Load Figure 4 nF 0.4 LOW SIDE WIRING DIAGRAM (Load Connected to “+”) °C/W Built-In Heat Sink Thermal Resistance (Vertically Mounted) 8 °C/W Heat Sink Thermal Time Constant 10 min Control Inputs/Power Outputs Insulation Voltage 4 kV Turn-On Time 10 µs Turn-On Delay 600 µs Turn-Off Time 10 µs Turn-Off Delay 100 µs On-Off Frequency 700Hz + DC Mains DC Control Power Supply – +– Ve Ie C1 D1 or D2 3+ Maximum Nominal Currents (Resistive) 100 Junction-Case Thermal Resistance or Ic Vt (Red paths as short as possible.) Vc 4– 58 (Red paths as short as possible.) D2 On-Off control Maximum Repetitive Pulse Avalanche Energy Output Capacitance (Typical) Ic 2– mJ C1 D1 or Vt Vc 750 Ve Ie 1+ V 4– Reverse Voltage (Internal Diode)1.6 + DC Mains – +– Units 2– Operating Range DC Control Power Supply 1+ HIGH SIDE WIRING DIAGRAM (Load Connected to “—”) On-Off control or or TIME DIAGRAMS TURN-ON Load Vc (control) Figure 5 t ON RESISTANCE VS. TEMPERATURE Vt (switch) 25 t ton TURN-OFF Vc (control) t RDSon (mOhms) tdon 20 15 10 5 Vt (switch) t tdoff toff 0 –50 0 50 100 150 Junction Temperature (°C) Figure 6 S20DC100 Page Figure 7 Specifications are subject to change without notice © 2006 TELEDYNE RELAYS S20DC100\062006\Q1 NEW Series S20DC100 Output to 100A, 200 Vdc DC Solid-State Relay POWER DISSIPATION AND LOAD CURRENT LIMIT VS. TEMPERATURE Please refer to the installation notice for precautions about mounting the device on a heat sink. 266 110 0.9°C/W 0.75°C/W 0.55°C/W 0.3°C/W 0.3°C/W 0.1°C/W 100 220 90 178 80 141 70 108 60 79.2 50 55 40 35.2 30 19.8 20 8.8 Power Dissipation (W) Load Current (Arms) 1.1°C/W 2.2 10 8°C/W 4°C/W 2.4°C/W 2.2°C/W 2.1°C/W 1.95°C/W 1.5°C/W 1.3°C/W 1.2°C/W 0 0 0 10 20 30 40 50 60 70 80 90 100 110 Ambient Temperature (°C) Figure 8 GENERAL SPECIFICATIONS (+25°C ambient temperature unless otherwise specified) ENVIRONMENTAL SPECIFICATIONS Min Max Units Operating Temperature –40 +90 °C Storage Temperature –40 +100 °C Input-Output Isolation 4000 1GΩ Insulation Capacitance <8 pF 175 Power Protection Level IP00 Protection Against Direct Touch None CE Marking Yes E.M.C. EMISSION Radiated & Conducted Disturbances NFEN55011 °C PROTECTIVE COVER AVAILABLE Add -14 to part number CONNECTIONS IEC60947-1 Vrms Insulation Resistance Junction Temperature GENERAL Standards Control Phillips NR2 Phillips NR1 Screwdriver Tightening Torque Insulated crimp terminals (Round Tabs, Eyelet Type) 1.8 N.m 0.8 N.m M5 M3 Figure 9 MISCELLANEOUS DisplayGreen LED (ON) Housing UL94V0 Mounting2 screws (M4x12mm) Noise LevelNo audible noise © 2006 TELEDYNE RELAYS NOTES 1. For additional/custom options, contact factory. S20DC100 Page S20DC100\062006\Q1