V6822_562_00_GB.fm Seite 1 Dienstag, 1. Juli 2008 7:44 07 © Merten2005V6822-562-0005/08 Connections, displays and operating elements Analogue actuator module REG/4-gang B K1 K2 K3 K4 Operating instructions D U/I U/I U/I U/I Technical data Auxiliary voltage: Current consumption: Current consumption on the system plug: Ambient temperature: Storage/transport temp.: Humidity Environment/storage/transport: A E K1 K2 K3 K4 F Art. no. MTN682292 I G H Necessary accessories – Analogue actuator REG-K/4-gang (Art. no. MTN682291) For your safety ¼ DANGER Risk of fatal injury from electrical current. The unit may only be installed and connected by skilled electicians. Observe the regulations valid in the country of use, as well as the valid KNX guidelines. C A Reference potential for outputs K1 to K4 B Analogue outputs K1 to K4 C External supply voltage for D D Analogue actuators (e.g. servomotors etc.) E Status LED (red) of the analogue actuator module F Status LEDs (yellow) of the four analogue outputs G System connection, 6-pin, for module connection H Auxiliary voltage connection I System connection, 6-pin, for future extensions Installing the module The following basic rules should be observed when installing a module: • A maximum of one module can be connected. Getting to know the module The analogue actuator module REG/4-gang (referred to as a module in the following) extends the analogue actuator REG-K/4-gang by four analogue outputs, which can be parameterised using software. • One module can be exchanged for another of the same type - e.g. if a module is faulty - while the system is in operation (disconnect module from voltage!). After a module has been replaced, the analogue actuator carries out a reset after approx. 25 seconds. This re-initialises all outputs on the analogue actuator and the connected modules and resets them to their original status. • Data received are converted into 0 to 1 V, 0 to 10 V, 0 to 20 mA or 4 to 20 mA output signals.These analogue output signals enable heating, air conditioning and ventilation system actuators to adapt their output variables based on bus information and to participate in control processes. • It is not permitted to add or remove modules without adapting the configuration and downloading it into the analogue actuator, as this may lead to system malfunctions. • The output variables can be prioritised. Status LED • The analysis of module data and priority operation processing take place in the KNX analogue actuator. ON • Outputs that are not required can be switched off. Flashing quickly • The output status is indicated by the status LEDs. • Suitable for installation onto DIN rails EN 50022. Voltage measurement impedance: Current measurement impedance: Type of protection: Device width: 6 mA -5 °C to +45 °C -25 °C to +70 °C max. 93% relative humidity, no condensation Screw terminals 0.5 mm2 to 4 mm2 0.34 mm2 to 4 mm2 0.14 mm2 to 2.5 mm2 6-pin system plug 4 DC 0 to 1 V, DC 0 to 10 V, DC 0 to 20 mA , DC 4 to 20 mA > 1 kΩ < 500 Ω IP 20 in accordance with EN 60529 4 TE = approx. 72 mm Schneider Electric Industries SAS If you have technical questions, please contact the Customer Care Center in your country. www.schneider-electric.com This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication. Device status (red) during module start-up: • The module is connected to the KNX device via the system plug provided. • Voltage outputs are monitored for short circuits. Connections Outputs, power supply: Single-core: Finely stranded (without core end sleeve): Finely stranded (with core end sleeve): Connection to the KNX device: Analogue outputs Number: Ranges: AC 24 V ±10 % max. 120 mA Flashing slowly OFF The module is ready for operation (self-test is ok) The module is currently being initialised The module is not projected (in the KNX device) The module is initialised and has been started up Requirement: The LED must have lit up beforehand. Device status (red) in normal operation: ON OFF The module is not ready for operation (error) The module is initialised and pre-programmed Requirement: The LED must have lit up beforehand. Flashing slowly = 1/s; flashing quickly = 2/s Output signals K1 to K4 (yellow): LED off: The output signal is equal to zero LED On: The output signal is greater than zero V6822-562-00 05/08 GB