 General Purpose Distribution Transformers, Single and Three Phase “Volt-­‐Master” Introduction: Signal Transformer announces its off-­‐the-­‐shelf, NEW “Volt-­‐Master” line of standard Single and Three Phase General Purpose Isolation, Low Voltage, Dry-­‐Type, K-­‐1 Factor distribution transformers intended for linear loads. All versions are UL recognized, CSA certified, built in the USA and tested in accordance with applicable NEMA, ANSI and IEEE standards. These durable, rugged, energy efficient classified products are available in both open air cooled or enclosed & ventilated versions exhibiting: •
•
•
•
Low Temperature Rise Low Sound Levels High Efficiency Smallest possible footprint and constructed using: •
•
•
•
•
Robust Electrostatic Shielding Copper Windings Powder Coated Steel Enclosures Vacuum Pressure Impregnation USA design & Fabrication The “Volt-­‐Master” series of General Purpose Distribution Transformers is rated for 60Hz @ 600V maximum and is divided into two categories: •
•
Small….. Three Phase; ranging from 350VA to 9KVA rated power. Large….. Single and Three Phase from 15KVA to 112.5KVA rated power. Large 15KVA-­‐112.5KVA “Volt-­‐Master” offerings are designed for Energy Savings, complying with NEMA TP1-­‐2002/DOE CSL-­‐1 as well as Energy Star, meeting Federally mandated minimum efficiency levels. All items within this family of Transformers are available in NEMA Type 1 or 2 Ventilated Enclosures for indoor applications or in NEMA-­‐3R Cases for outdoor use. Markets: •
•
•
•
•
•
•
•
Commercial Industrial Healthcare Institutional Agricultural Residential Utility HVAC Applications: General Purpose Distribution Transformers rated for 60Hz, @ 600V and below are utilized to supply appropriate power to loads powered directly by electrical distribution systems, such as: •
•
•
•
•
•
•
•
•
•
•
•
•
•
Appliances Lighting Heaters Air-­‐conditioners Fans & Blowers Machine Tools & Plant Equipment X-­‐ray Equipment Programmable Controllers Data Process Instrumentation Computers Safety Alarms Telecommunication Systems Radar Systems Test Control & Measurement This class of transformers is also used by power builders and equipment OEM customers who incorporate them as integral parts of their constructs. When equipped with enclosures, these transformers are installed in commercial, educational and government facilities as well as in industrial plants, office buildings, hospitals, hotels and data centers. They can also support renovations, upgrades and modernization efforts, or any new projects requiring voltage conversion compliant with local and state regulations. NEMA TP1-­‐2002/DOE CSL-­‐1, Energy Star rated transformers, 15KVA and above @ 600V or less, are specifically designed with the intent of providing reduced cost of ownership by being optimally designed for energy efficiency. These transformers can yield considerable energy savings over their functional lifespan and meet the requirements of the Energy Policy and Conservation Act of 2005 under Federal Code 10 CFR part 431. This act applies to all such transformers put into service within the United States after January 1st of 2007. Features: •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Copper Winding Conductors as Wire or Foil and Copper Terminations; Standard Quiet Performance per NEMA ST-­‐20 and IEEE C57.12.01 Maximum Sound Levels VPI-­‐Vacuum Pressure Impregnation with High Quality Insulating Varnish; Standard Electrostatic Shield; Standard (Double Grounded, Full Current Carrying Capability for effective, High Frequency Noise Suppression) Complete Ground Protection for Earth and Secondary Neutral Grounding. Low Temperature Rise with utilization of oversized conductors. High Efficiency through design optimization and material selection. Air Cooled, Open Frame and NEMA 1/2/3R Enclosure configurations High quality, Non-­‐Aging, Electrical Grade, Grain Oriented Silicon Steel. FCAN&FCBN 2.5%-­‐5% Primary Taps; Standard (to Allow for Source Voltage Variations) UL Class H, 180 Degrees C Insulation System Meets minimum BIL of 10KV for 600V-­‐Class Windings Short Term Overload Capacity as per ANSI C57.96-­‐01.250 DIN Rail Track affixed to Core for Fuse, Breaker and Sensor installation; Standard UL 506/5085-­‐1 recognized & CSA C22.1 No. 66.1 certified Built and Tested per applicable NEMA/ANSI/IEEE/UL/CSA/OSHA/NEC Standards “Made In the USA” Compliant to ARRA/BAA/TAA/SPPA 73 P.S.1881 MTBF of 20 Years as defined by ANSI C57.96 for Continuous Full Duty Operation Warranty of 15 years Standard Compliance: •
•
•
•
•
•
•
•
•
ANSI/IEEE C57.96, C57.12 & C89.2: Dry Type Distribution Transformers (General Requirements for Loading, Testing & Sound Levels) ANSI/NFPA 70: National Electrical Code (Installation and Safety) NEMA ST-­‐20: Dry Type Transformers (General Applications and Sound Levels) NEMA 250: Enclosures for Electrical Equipment NEMA TP-­‐1/2/3-­‐2002: Dry Type Transformers (efficiencies, testing & labeling) UL 506: General Purpose and Specialty Transformers UL-­‐1561: General Purpose and Dry Type Transformers UL 5085-­‐1: General Requirements for Low Voltage Transformers CSA C9/C22.1 No.66.1/47: Dry Type, Air Cooled & Specialty Transformers Specifications: A. Small Three Phase 60Hz: 1. Power Range: 350VA-­‐500VA-­‐750VA-­‐1KVA-­‐1.5KVA-­‐2KVA-­‐3KVA-­‐6KVA-­‐9KVA 2. Voltage Range: a. DELTA Primary: 208V-­‐240V-­‐380V-­‐400V-­‐415V-­‐480V-­‐575V-­‐600V b. WYE Secondary: 208Y120V-­‐380Y220V-­‐400Y230V-­‐415Y240V-­‐480Y277V-­‐575Y330-­‐600Y347V 3
Dimensions (in) & Weight (Lbs): KVA CORE COIL DIM’s ENCLOSURE DIM’s H W D WT H W D WT 0.35 4.00 4.25 4.00 9.00 10.0 8.0 8.0 16.0 0.50 4.75 6.00 4.00 13.0 10.0 8.0 8.0 20.0 0.75 5.50 7.50 3.50 18.0 12.0 10.0 10.0 30.0 1.00 5.50 7.50 4.00 23.0 12.0 10.0 10.0 35.0 1.50 5.50 7.50 4.50 28.0 12.0 10.0 10.0 40.0 2.00 5.50 7.50 4.75 32.0 12.0 10.0 10.0 45.0 3.00 5.50 7.50 6.00 42.0 12.0 10.0 10.0 55.0 6.00 6.75 9.00 6.75 70.0 15.0 13.0 13.0 95.0 9.00 8.25 9.00 7.25 85.0 15.0 13.0 13.0 110.0 * Dimensions and Weights are approximate and subject to change. B. Large Three Phase 60Hz Energy Efficient TP-­‐1-­‐2002 Rated: 1. Power Range: 15KVA-­‐20KVA-­‐25KVA-­‐30KVA-­‐45KVA-­‐50KVA-­‐75KVA-­‐112.5KVA 2. Voltage Range: a. DELTA Primary: 208V-­‐240V-­‐440V-­‐480V-­‐600V b. WYE Secondary: 208Y120V-­‐220Y127V-­‐415Y240V-­‐480Y277V 3. Dimensions (in) & Weight (Lbs): KVA CORE COIL DIM’s ENCLOSURE DIM’s H W D WT H W D WT 15 13.2 14.5 8.25 165.0 22.0 17.0 17.0 210.0 20 13.2 14.5 6.63 190.0 22.0 17.0 17.0 235.0 25 13.2 14.5 7.50 210.0 22.0 17.0 17.0 260.0 30 15.0 20.0 4.50 250.0 24.0 24.0 19.0 315.0 45 15.0 20.0 6.50 340.0 24.0 24.0 19.0 530.0 50 15.0 20.0 8.50 385.0 24.0 24.0 19.0 455.0 75 20.0 22.0 9.00 535.0 32.0 26.0 19.0 608.0 100 20.0 22.0 10.0 675.0 32.0 26.0 19.0 750.0 112.5 20.0 22.0 11.0 735.0 32.0 26.0 19.0 810.0 * Dimensions and Weights are approximate and subject to change. C. Large Single Phase 60Hz Energy Efficient TP-­‐1-­‐2002 Rated: 1. Power Range: 15KVA-­‐25KVA-­‐37.5KVA-­‐50KVA-­‐75KVA-­‐100KVA 2. Voltage Range: a. Primary: 120Vx240V 208x416 240x480 Dual Winding 208V-­‐277V-­‐480V-­‐600V Single Winding b. Secondary: 120V/240V 3
Dimensions (in) & Weight (Lbs): KVA CORE COIL DIM’s ENCLOSURE DIM’s H W D WT H W D WT 15 9.0 9.00 11.0 135.0 22.0 17.0 17.0 180.0 25 12.0 12.0 10.0 175.0 22.0 17.0 17.0 220.0 37.5 12.0 12.0 12.0 245.0 22.0 17.0 17.0 290.0 50 15.0 15.0 12.0 285.0 24.0 24.0 19.0 355.0 75 15.0 15.0 15.0 405.0 32.0 26.0 19.0 480.0 100 15.0 15.0 18.0 510.0 32.0 26.0 19.0 585.0 * Dimensions and Weights are approximate and subject to change. Combining the latest technologies with advanced features and superb materials, Signal Transformer delivers once again another high quality product line with great performance and reliability through excellent customer service and support. 