SIGNAL ANALYZERS EMC Design Course/EMI Measurement Software Models 11949A, 85869A, 85870A, 85874A Locate EMI "hot spots" quickly Increase EMI measurement repeatability Utilize powerful analysis aids Begin testing at system turn-on Test to standard or internal limits Automatically correct data for transducer and system gain/loss HP 11949A EMC Design Course HP 85869A EMI Measurement Software "Designing for Electromagnetic Compatibility" is a new, two-day course for engineers who face issues of electromagnetic compatibility. Emphasis is on evaluating and solving EMC problems early in the design phase, rather than during final EMC-compliance testing. Instruction and demonstrations provide EMC fundamentals, methods of measuring EMC, and principles of incorporating proven EMC design into products. Topics include radiation from digital circuits, nonconductive coupling, diagnosing EMI problems, shielding, commonimpedance coupling, susceptibility, cables, and electrostatic discharge. An 11-chapter handbook used in the class serves as a permanent reference. For locations and dates near you, call your local HP sales office listed on page 739. The HP 85869A EMI Measurement Software is a general-purpose program for making automatic commercial and military emission measurements using an HP 8566B, 8567A, or 8568B Spectrum Analyzer. The friendly menu structure of the program leads you through an EMI measurement from initial setup to the final plotting of the test results. The HP 85869A has an easy start-up procedure, so you are "ready to run" even if you have never programmed before. HP 85870A Open-Site EMI Measurement System Software The HP 85870A Open-site EMI Measurement System (OEMS) Software is specially designed to automate and simplify commercial EMI, radiated-emission compliance measurements. EMI measurements made at open sites, due to ambient signals present in the measurement environment, are inherently more complex than measurements made in shielded enclosures. The HP 85870A helps EMI engineers and technicians quickly obtain repeatable, accurate, and completely documented measurement results using the HP 8573A and 8574A EMI Receivers. Identify and record ambients The OEMS Software allows you to identify and categorize ambients by automatically (or manually) generating a list of the frequencies and amplitudes of ambient signals that are present when the equipment under test (EUT) is off. The ambient list is incorporated into a user-defined frequency-band table, which allows you to segment the entire range of interest and categorize the ambients in each band. For example, you can specify and label the 6-meter ham, FM radio, and land mobile bands in the frequency-band table. Methods are provided to generate and maintain complex ambient signal lists for repeated use. The spectrum analyzer screen is marked where the ambient signals occur for simplified identification of suspect EUT emissions. Identify and maximize EUT emissions With a complete ambient list and a remote AC power switch, the software can automatically turn on the EUT and find suspect emissions, even in the presence of impulsive or noisy environments. The EMC engineer or technician can then select from a number of features such as Tune & Listen, EUT On/Off, and Zoom Local to determine which signals are coming from the EUT. Confirmed emissions are assigned to a final list of signals. Each emission's amplitude is then determined by automatically controlling a turntable and antenna mast using a signal characterization routine of your choice. EUT emissions can be manually maximized using the SIG PEAK function, which controls an HP-IB antenna mast and turntable or allows manual positioning. The OEMS software records information on each signal such as frequency and amplitude deviation from the limit, as well as the antenna height, turntable position, and user comments. Generate complete reports in desired formats Complete measurement results are documented in the format of your choice using the OEMS Software Report Generator. You can design your own test report using combinations of fixed text and updateable variable fields for the date and time of test, equipment name and serial number, or any other information. Ambient, suspect, or final signal lists and log frequency plots of the final data can be integrated with your text for concise, professional-looking reports. A library is provided to store these report formats. CRT data and signal lists can also be sent to a printer or plotter from virtually any point in the software. Automate MIL-STD and commercial EMI measurements The HP 85869A EMI Measurement Software automates military and commercial EMI emission measurements. It is designed to automate EMI measurements made in a shielded enclosure. The HP 85869A takes advantage of the spectrum analyzer's ability to quickly measure wide frequency spans and locate EMI "hot spots" using peak detection. For commercial measurements, quasi-peak data need be taken only at these "hot spots." Save time and effort in your MILSTD measurements by letting the software automatically descriminate between narrowband and broadband signals. Design your own tests Design your own tests or choose from the examples given in the software. These examples reside in the test library and include MILSTD, FCC, and VDE/FTZ emission tests. Transducer factors, test limits, and receiver parameters are easily changed and stored in libraries. Once your test is designed, it is stored away and can be executed repeatedly at the push of a key. Compatibility The HP 85869A and 85870A are compatible with the following equipment: Spectrum Analyzer* HP 8566B, 8567A, 8568B HP 85685A RF Preselector HP 85650A Quasi-Peak Adapter HP 8573A, 8574A EMI Receiver Computer* HP 9000 Series 300 Model 310, 319, 320, 330, 332, 340, 350, 360, 370 HP 9000 Series 200 Model 216, 236 Memory Requirements* 2 Mbytes Mass Storage* HP 9122C, 9153C HP 7440A, 7475A, 7550A Plotters Printers HP 2225A, 2227B, LaserJet Series II, DeskJet DMA Controller HP 98620B Floating Point Card HP 98635A HP 50962A SRM Interface 'Minimum equipment required Ordering Information HP 11949A "Designing for EMC" Course HP 85869A EMI Measurement Software Opt. 630 3 1/2-inch media Opt. 655 5 1/4-inch media Opt. 830 Upgrade kit for HP 85864A/B/C software, 3 1/2-inch media Opt. 855 Upgrade Kit for HP 85864A/B/C software, 5 l/4-inch media HP 85870A OEMS Software Opt. 630 3 1/2-inch media Opt. 655 5'/4-inch media HP 85874A Bundled EMI Software Includes HP 85869A and 85870A Opt. 630 3 1/2-inch media . Opt. 655 5 1/4-inch media Price $750 $0 $5,000 $5,000 $500 $500 $0 $5,200 $5 200 $0 $7,280 $7,280 SIGNAL ANALYZERS Impulse Bandwidth/EMI Diagnostic Measurement Card/EMI Accessories HP 8566B/68B Option 462 Option 462 for HP 8566B and 8568B spectrum analyzers provides impulse bandwidths for making MIL-STD and DEF STAN EMI measurements. Standard HP 8566B and 8568B models have 12 resolution bandwidth filters (10 Hz to 3 MHz in a 1, 3, 10 sequence) specified in terms of their 3 dB bandwidth. Option 462 modifies the 1 kHz to 3 MHz resolution bandwidth filters to correspond to their impulse bandwidth instead. In addition to enhancing instrument capability for MIL-STD 461A/B/C and 462 EMI measurements, spectrum analyzers with Option 462 can still make all commercial EMI and general-purpose measurements. Option 462 spectrum analyzers are compatible with the HP 85650A Quasi-peak Adapter, HP 85685A RF Preselector, HP 85864C EMI Measurement Software, HP 85870A Open-site Measurement Software and the HP 85867A EMI Receiver Functions program. Existing HP 8566B and 8568B spectrum analyzers can be modified to include Option 462. For more information, contact your local sales office listed on page 739. HP 85712A EMC Diagnostic Measurement Card This memory card customizes the new HP 8590B and 8591A, 8592B, and 8593A spectrum analyzers for electromagnetic-compatibility testing. When you use these EMC-evaluation analyzers with the HP 11945A close-field probe set, you have capability for comprehensive diagnostic electromagnetic-interface measurements. (For more information on the portable spectrum analyzers, see page 104.) HP 11940A and 11941A Close-field Probes These small, hand-held electromagnetic-field sensors are used with a spectrum analyzer for EMI diagnostic and troubleshooting applications. A dual-loop configuration and balun structure enable them to make repeatable, absolute magnetic-field measurements. The HP 11941A operates from 9 kHz to 30 MHz; the HP 11940A, from 30 MHz to 1 GHz. Designed to measure radiation from surface currents, slots, and cables, these probes are ideal for diagnostic testing of printed circuit boards, cabling, and shielded enclosures. Five antenna factor points appear on the back of each probe for calculating absolute magneticfield strength (dBuA/m) from the spectrum analyzer's dBuV reading. Double-shielded cables and adapters are included with the HP 11945A Close-field Probe Set, which includes both probes. Option E51 adds the HP 8447F Option H64 Preamplifier and a convenient carrying bag. HP 11947A Transient Limiter The model HP 11947A Transient Limiter protects a spectrum analyzer input from the damage caused by high level transients from line impedance stabilization networks (LISNs) during EMI testing for conducted emissions. A high-pass filter and a 10 dB attenuator are incorporated into the HP 11947A Transient Limiter, which is capable of withstanding inputs as high as 10 kW for 10 Msec, or 2.5 W of average power. The built-in high pass filter helps reduce 60 Hz line feedthrough that might impede conducted emission measurements. Recommended EMI Transducer Kits HP EMC Design Support Tools Ordering Information HP 8566B/68B Option 462 HP 85712A EMI Diagnostic Measurement Card Recommended EMC Configurations HP 8590B RF Spectrum Analyzer Opt 010 Tracking Generator, 50 Ohms Opt 021 HP-IB Interface HP 8591A RF Spectrum Analyzer Opt 010 Tracking Generator, 50 Ohms Opt 021 HP-IB Interface HP 11945A Close-field Probe Set Option E51 adds preamplifier, accessory-carrying bag, and 36-inch, Type N cable Price $2,C 40 $560 $8,995 $3,200 $600 $ 12,000 $3,600 $600 $1,100 $2,510 HP 11941A Close-field Probe (9 kHz-30 MHz) $650 HP 11940A Close-field Probe (30 MHz-1 GHz) Option 001 Rotary Joint HP 11947A Transient Limiter $650 $3 !5 $470 EMI Accessories Price Turntable for Radiated Emission Testing Equipment Testing Turntable with HP-IB control. HP 85685A Option K40: 50-60 Hz, 100-120 volts $9,725 HP 85685A Option K41: 50-60 Hz, 220-240 volts $9,725 Tower for Radiated Emission Testing. Antenna Positioning Tower with HP-IB and polarization control. HP 85685A Option K42: 50-60 Hz, 100-120 volts $15,3 5 HP 85685A Option K43: 50-60 Hz, 220-240 volts $15,3 5