BR_JHG-Powerstar_24_kVA_3-Ph_en_08-12_07

advertisement
MLT DRIVES
Technical Specifications
PowerStar 24 kVA 3-phase Inverter
Model: MPC-24K-3P48V003
MLT DRIVES
97 Garfield Road,
Kenilworth
+27 21 683 3310
+27 21 674 2823
www.mltdrives.com
Powerful
Designed for off-grid and bi-directional operation
Efficient
High inverter efficiency up to 94%
Robust
High tolerance to surges and high temperatures
 Full automatic operation with no break to the supply during transitions from inverter to grid or
generator parallel operation.
 The backup generator (if installed) can automatically be started when the grid fails.
 Renewable energy is fed directly to the load to overcome inefficiencies from the batteries.
 Capable of being integrated with renewable/distributed generation sources on both the AC and DC
bus.
 Local LCD (liquid crystal display) and keypad can be used to change settings, monitor all supplies
(Voltage, Current, Watts etc) and view event/fault logs (time and date stamped).
 Load sensing capability. System goes to low power standby when no load is connected.
 Smart load control. Certain non-essential loads can be turned off automatically when not enough
energy is available.
 Optional build in max. two MPPT regulator (5 kWp) for maximizing PV power.
Multi-Power Control System
Grid
Solar Array
MPPT Solar
Charge controller
Generator
Powerstar
Inverter
Battery
Load
Inverter
Wind turbine
INVERTER –
PARAMETERS
INFORMATION
Nominal AC Output Voltage
380 volts 1 %, three phase, 4 Wire output.
Nominal voltage can be adjusted by 10% via system settings
50 Hz 0.5 % nominal, (47 to 63 Hz adjustable).
Inverter to follow grid/generator frequency up to 5 Hz of the
nominal output frequency during parallel operation
24 kW (Inverter Only), 35 A AC max. per phase.
Up to 36 KVA (150 % of the continuous rating) for a maximum of
30 seconds. Up to 48 kVA for 5 seconds.
48 Volt DC
450 A Maximum
Voltage source, microprocessor regulated
Low THD, Pure sine-wave output
Phase Controlled Pulse Width Modulation (PWM)
Less than 3 %
Up to 94 % stand alone, 95 % or more when in parallel AC source
140 W (2.55 A typical)
8 W power consumption when in standby.
Automatically goes to standby when load is too low. Adjustable
low load threshold.
 Inverter continuous overload protection
 Inverter short circuit protection
 Heat-sink over temperature protection
 Over/under voltage AC voltage protection
 Over/under frequency protection
 Over/under battery voltage protection
Via system fault relay (voltage free contact)
Output Frequency (Adjustable)
Continuous AC Power (30°C)
Surge Rating
Battery Voltage (nominal)
Battery Charge Current (Adj.)
Control Type
Waveform
AC Power Control
Output Harmonic Distortion
Efficiency
No Load Power Consumption
Standby - Load Sensing
Internal Protection System
(using electronic detection)
Alarm Signals
INVERTER –
PARAMETERS
INFORMATION
Front Panel Display (LCD)
40x4 LCD panel with membrane keypad displaying the following:
 Grid/Generator and inverter per phase kW, KVA, voltage, freq.
 Grid/Generator and inverter on line status
 Battery voltage, battery current, battery temperature
 Solar current, power and voltage
 Heat-sink and cabinet temperature
 Inverter, Generator Load kWh summation, Generator run
hours
 System settings, event logs
Front Panel Controls (via keypad)
System On-Off, Equalise Battery, Force Start Generator
Circuit Breakers
 Grid and Generator Input
 Battery Input Fuse Breakers
Designed to minimise both conducted and radiated EMI
emissions, operation with external EMI-Filter EPA NF-4-40
(40 A + neutral wire).
negative ground, AC surge protection to ground
EMI
Earthing Provisions
AC Input specifications
(Grid and Generator)
Capacity
Nominal Voltage & Frequency
Control
Adjustable from 9 kVA to 24 kVA single phase
380 volts 50 Hz, 4 wire. Operating voltage can be adjusted by
5%
Local keypad (HMI)
Environmental
Operating Temperature Range
Humidity
Enclosure
-5 to 45 Grad Celsius
0-90% non condensing
Rated for IP 30 – not weatherproof
Enclosure
Dimensions
Weight
550 (W) x 510 (D) x 1200 (H)
280 kg
Solar MPPT Controller
Control type
Capacity
Enclosure
(optional)
Dual-Channel PWM (pulse width modulated)
Standard 5 kW peak (80 amps max at the nominal battery volts).
Incorporated in the inverter control cabinet (top section)
Logging
Event and Fault Logging
System Summations
Up to 4000 events and faults are logged, accessible from locally
All events have date and time stamps.
Load, Generator, Inverter, Battery and Solar kWh
Communications
RS485, RS232
GSM
(optional)
MODBUS RTU slave port
Remote Communications using built in GSM Modem
Multi Purpose
Input/Output Card
Relay (Voltage Free)
(optional)
Sensor Inputs
3 Relays Configurable – Non Essential Loads,
Generator Start & Crank, Alarm, Fan
Battery Temperature, System Hot Bypass, E-Stop, Fuel Level
JHG – Powerstar
Performance Summary (Power)
Power [kVA]
Number of Phase
6
8
12
16
18
24
1~
1~
1~
1~
1~
3~
1~
3~
Renewable Energy Systems:
Europe Representative:
Johannes Hübner Fabrik elektrischer Maschinen GmbH ◊ Siemensstraße 7, 35394 Giessen
www.huebner-giessen.com ◊ Phone: ++49-641-7969 0
info@huebner-giessen.com
Fax: ++49-641-7969 81
Download