® Configurable Packaged Air Handling Equipment 1 VALENT A MANUFACTURER OF HIGHLY-CONFIGURABLE AIR HANDLING EQUIPMENT DESIGNED TO MEET THE NEEDS OF ENGINEERS, CONTRACTORS AND BUILDING OWNERS Valent assembly line in Minneapolis, MN. 2 QUALITY RELIABILITY At Valent’s core is a commitment to quality expressed As evidenced in the use of direct-drive supply and in the following four categories: exhaust fans, energy recovery options with no People We believe that quality products begin with quality people, which is why we continuously invest in the moving parts, and a dependable controls platform, Valent equipment is designed for safe, consistent performance throughout its entire service life. development of our teams. FLEXIBILITY Performance Valent’s product portfolio offers multiple forms of Quality products are not manufactured by cooling, heating, and energy recovery in four different accident; they are the result of repeatable, casing sizes to fit a wide range of applications. quality-focused processes. Partners SUPPORT The internal components of our products play a vital While the shipment of a unit from one of our two role in unit operation; as such, we partner only with US-based manufacturing facilities marks the end of manufacturers who share our passion for quality. the production cycle, it is only the beginning of the commitment to our customers and their investment Products in our products. Valent’s engineering and design teams not only focus on quality in new product development, but regularly revisit existing designs to improve quality and manufacturability. 3 APPLICATIONS VALENT PRODUCTS ARE DESIGNED TO OPERATE IN A WIDE RANGE OF APPLICATIONS AND SYSTEMS 4 K-12 Education Higher Education Hospitality Office Manufacturing Healthcare Laboratory Food Service DEDICATED OUTDOOR AIR SYSTEMS MAKE-UP AIR SYSTEMS Dedicated outdoor air systems (DOAS) are defined by and require greater control over space conditions. the separation of space and ventilation loads. DOAS With the ability to precisely control leaving air ventilation loads are almost exclusively 100% outdoor temperatures of 100% outdoor air loads in heating, air and typically at volumes where air-to-air energy cooling, and dehumidification modes, Valent make-up recovery is required. Valent offers a broad range of air units are up to the demands of these installations. Make-up air systems continue to grow in complexity cooling, heating, and energy recovery combinations for direct integration into these systems. VARIABLE AIR VOLUME SYSTEMS COMFORT COOLING SYSTEMS Variable air volume systems (VAV) are commonly While standard minimal-outdoor air packaged rooftops used to address the wide range of load distribution can meet the needs of these systems, many owners within a space. With features such as VFD-driven and engineers see benefit to using a fully-featured supply and exhaust fans, cooling and heating capacity air handler in its place. Valent products are well suited modulation, and integral energy recovery, Valent towards these installations with modulating cooling equipment is designed to handle the variation capacity, a true dehumidification cycle, low-sound these systems demand. condensing fans, and air-to-air energy recovery in a single footprint. 5 PRODUCTS MULTIPLE PRE-CONFIGURED PLATFORMS PROVIDE AN ARRAY OF SOLUTIONS TO BEST MEET THE NEEDS OF EACH APPLICATION FACTORY RUN TESTING All Valent equipment is subject to a factory run test that involves much more than simply energizing components to verify if they enable. With an average run time of 90 minutes, Valent’s test technicians review a broad range of operating parameters in the following categories: • Refrigeration – refrigeration systems run at multiple conditions where superheat and subcooling performance are recorded and evaluated • Heating – heating elements tested as installed inside each unit using the as-ordered fan arrangement • Electrical – individual component continuity and phasing verified • Airflow – fans are inspected for smooth rotational characteristics as installed in the unit 6 PACKAGED AIR HANDLERS VPR and VPRX Series The VPR and VPRX series are capable of cooling, heating, and dehumidifying a wide range of entering air loads, up to 100% outdoor air. In applications with lower outdoor air requirements, the VPRX offers powered exhaust fans for pressure relief and economizer control. PACKAGED ENERGY RECOVERY AIR HANDLERS VPRE Series Valent’s most common energy recovery ventilator, the VPRE series, expands upon the VPR packaged platform with an air-to-air enthalpy wheel and powered exhaust fan section. Two media types are available to best suit the needs of each application; a lightweight polymer wheel with a silica gel desiccant or aluminum wheel with a molecular sieve. VPRC Series VPRP Series When recovering sensible and latent energy is a In applications where sensible-only energy recovery priority but the maintenance requirements of an is desired, the VPRP delivers with an all-aluminum enthalpy wheel are unwanted, the VPRC with enthalpic plate heat exchanger that offers low pressure drops core heat exchanger is an excellent alternative. and extremely low leakage rates. Although commonly In addition to offering extremely low leakage rates, used in dry climates, the VPRP is also an effective the polymer media of the core heat exchanger can solution whenever space humidity levels are high, safely handle the accumulation of condensate and such as in a locker room. will not sustain damage from the formation of frost. 7 COOLING AND HEATING MULTIPLE HEATING AND COOLING OPTIONS ALLOW FOR STAND-ALONE OPERATION OR INTEGRATION WITH A CENTRAL SYSTEM REFRIGERATION TECHNOLOGIES Capacity Modulation The cooling and dehumidification loads of high outdoor air volumes vary greatly throughout each season, month, and day of operation. Despite this variation, Valent is able to provide tight control over space temperature and humidity through several technologies, including: Digital ScrollTM compressors, multi-circuit refrigeration systems, and tandem compressor sets. Modulating Hot Gas Reheat With our roots in 100% outdoor air dehumidification, Valent has always offered a robust hot gas reheat system to maintain control over leaving air temperatures. Transferring energy through a high-efficiency, 5/16” tube hot gas reheat coil, the system modulates the flow of refrigerant to achieve tight control of the discharge air temperature during dehumidification mode. Active Head Pressure Control Active management of the refrigerant head pressure dramatically improves dehumidification performance at part loads — resulting in greater control over space conditions. Valent’s premier method of head pressure control, AHPC 2.0, varies the flow of air across the condensing coil through a set of modulating condensing fans featuring noise-reducing blade technology and brushless DC motors. 8 COOLING Packaged Air Cooled DX Water Source Heat Pump Valent equipment with packaged air cooled Capable of operating on boiler-tower or geothermal direct-expansion (DX) refrigeration systems are water loops, Valent’s water source heat pump designed to operate over a wide range of loads and refrigeration systems deliver greater efficiencies ambient conditions. Within each nominal tonnage, than equivalent air cooled units. Standard on all two coil sets are offered to best fit the application: water source heat pumps is an advanced head Dehumidification, designed for applications with pressure control system that optimizes unit operation large dehumidification loads; and High Airflow, in cooling, dehumidification, and heating modes and intended for airflows that will see a broad range of protects against freezing. In addition, energy transfer loading from dehumidification to comfort cooling. between water and refrigerant is through a coaxial All air cooled package DX systems utilize condensing heat exchanger designed to handle the low entering coils with 5/16” tubes to increase the efficiency at water temperatures of geothermal systems. which heat is rejected into the atmosphere. Air Source Heat Pump Split Air Cooled DX Built on the same platform as the packaged air cooled Valent’s split air cooled DX refrigeration system DX system, the air source heat pump offers a reversing utilizes the same platforms and technologies as our cycle to move heat from the outside air to the supply packaged air cooled products but is paired with a air. The air source heat pump is capable of heating as remote condenser in lieu of a local condensing section. low as 17°F ambient — below this temperature the on Compressors remain mounted in the indoor unit for board controller will automatically switch to auxiliary reliability and piping simplification, eliminating the heat. Unlike most air source heat pumps, the defrost need for a third refrigerant line on circuits with hot cycle developed by Valent is not based solely on timers; gas reheat. In addition, Valent’s ability to provide true rather, the program determines if conditions exist for horizontal connections on energy recovery equipment freezing prior to deploying a defrost cycle. The result? without the use of an adapter curb make indoor Fewer unnecessary defrost cycles performed with installations much easier to execute. less energy consumed. HEATING Valent products are available with a number of heating options to best meet the needs of each application. • Indirect Gas – always modulating, available in 4:1 or 10:1 turn-down • Temperator – hybrid heating system pairing a 4:1 modulating furnace with a small SCR electric heater for total capacity modulation • Electric – modulation achieved through SCR • Hot Water – allows connection to hot water loop in lieu of a gas line or increased electrical loads 9 OPTIONS AND CAPACITIES PRE-ENGINEERED OPTIONS AND CASINGS ENHANCE APPLICATION FLEXIBILITY E D A A B F A C C A – Filtration C – Duct Connections E – Head Pressure Control • Washable aluminum • Vertical • Standard staged fans • MERV 8 • Horizontal • Active Head Pressure Control 2.0 with brush-less DC motors, noise-reducing blade technology, and uniform control strategy • MERV 11 (+MERV 8) • MERV 14 (+MERV 8) B – Controls • Space or discharge temperature and humidity control • Modulating supply fan, exhaust fan, or dampers based on pressure, CO2, or 0-10 VAC signal • Single-zone VAV • Refrigeration-only Controls Lite option 10 D – Energy Recovery • Polymer enthalpy wheel • Aluminum enthalpy wheel • Sensible-only flat-plate • Enthalpic flat-plate F – Refrigeration • Modulating hot gas reheat • Dehumidification-specific or broad-range evaporator coil sets AIRFLOW CAPACITIES Nominal Airflow [CFM] 650 1,000 1,500 VPR/VPRX 2,000 3,000 4,000 5,000 7,500 10,000 12,500 15,000 17,500 20,000 22,500 110 210 AIRFLOW CAPACITIES 310 350 VPRE 110 210 310 350 VPRP 110 210 310 350 VPRC 110 210 310 350 Airflow ranges are shown with packaged air cooled DX refrigeration and do not take into account actual design loads. REFRIGERATION CAPACITIES REFRIGERATION CAPACITIES Nominal Tonnage 5 Packaged Air Cooled 8 10 13 16 18 20 25 30 35 40 50 60 110 210 310 350 Split Air Cooled 110 210 310 Water Source Heat Pump 110 Air Source Heat Pump 110 210 210 HEATING CAPACITIES Input Capacity [MBH] HEATING CAPACITIES 100 Indirect Gas, Temperator 150 200 300 400 500 600 700 800 900 1200 150 200 110 210 310 350 Electric Capacity [kW] 10 15 SCR Electric 20 30 40 50 60 100 125 110 210 310 350 Electric heat sizes shown at 460 VAC. 11 ® Contact your Valent representative today for more information. www.valentair.com 60 28TH AVENUE NORTH, SUITE 100 MINNEAPOLIS, MINNESOTA 55411 T – 612.877.4850 Valent is a business of Unison® Comfort Technologies. © 2014 Valent. CB.10.2014