11 FEEDER, CONDUIT OR RELAY SCHEDULE TAG JUNCTION BOX - CEILING OR WALL MOUNTED, SIZE TO CODE, TAPE AND TAG WIRES. PROVIDE FLEX AND/OR RECEPTACLE AS REQUIRED TO CONNECT EQUIPMENT. C. BEFORE BEGINNING CONSTRUCTION, PROVIDE TO THE ARCHITECT A CONSTRUCTION SCHEDULE OF ELECTRICAL WORK. THE CONSTRUCTION SCHEDULE SHALL IDENTIFY ALL SIGNIFICANT MILESTONES WITH COMPLETION DATES. PANELBOARD - FLUSH MOUNTED. D. OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTION FEES REQUIRED BY THIS CONTRACT WORK, UNLESS OTHERWISE NOTED. PANELBOARD - SURFACE MOUNTED. E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF PERSONS AND PROPERTY AND SHALL PROVIDE INSURANCE COVERAGE AS NECESSARY FOR LIABILITY, PERSONAL, PROPERTY DAMAGE, TO FULLY PROTECT THE OWNER, ARCHITECT AND ENGINEER FROM ANY AND ALL CLAIMS RESULTING FROM THIS WORK. F. MAINTAIN RECORD DRAWINGS AT THE PROJECT SITE INDICATING ALL MODIFICATIONS TO ELECTRICAL SYSTEMS. AT THE CONCLUSION OF THE PROJECT, PROVIDE ACCURATE "AS-BUILT" DRAWINGS ACCEPTABLE TO THE ARCHITECT. G. ALL MATERIALS PROVIDED FOR THE PROJECT SHALL BE NEW, UNLESS OTHERWISE NOTED. PROVIDE ALL INCIDENTAL MATERIALS REQUIRED FOR A COMPLETE INSTALLATION. H. PROVIDE ALL REQUIRED "CUTTING, PATCHING, BACK FILL AND REPAIRS" NECESSARY TO RESTORE DAMAGED SURFACES TO EQUAL OR BETTER THAN ORIGINAL CONDITIONS EXISTING AT START OF WORK. I. ALL ELECTRICAL EQUIPMENT INSTALLED OUTDOORS SHALL BE WEATHERPROOF. EXTERIOR CONDUIT RUNS INTO BUILDINGS SHALL BE INSTALLED WITH FLASHING, CAULKED AND SEALED. CONDUITS FOR EXTERIOR ELECTRICAL DEVICES SHALL BE RUN INSIDE BUILDING, UNLESS OTHERWISE NOTED. UNDERGROUND AND EXTERIOR CONDUIT SHALL HAVE WATERTIGHT FITTINGS. J. ALL CONDUITS SHALL BE 3/4" MINIMUM UNLESS OTHERWISE NOTED. POWER AND LIGHTING BRANCH CIRCUITS SHALL HAVE A MINIMUM TWO (2) #12 AWG AND ONE (1) #12 AWG GROUND TYPE THWN/THHN. THE CONTRACTOR SHALL SIZE CONDUCTORS FOR VOLTAGE DROP. DEDICATED NEUTRALS ARE REQUIRED FOR ALL 1-POLE CIRCUIT BREAKERS. ALL POWER WIRING SHALL BE RUN IN CONDUIT. THE USE OF MC CABLE IS PERMITED IN INDIVIDUAL ROOMS ONLY. ALL HOMERUNS SHALL BE IN CONDUIT, PROVIDE WIRES AND WIRE SIZES AS REQUIRED BY CODE AND AHJ. THE USE OF ROMEX (NMC) IS NOT PERMITTED. K. CONDUITS SHALL NOT BE USED AS A GROUND PATH. ALL CONDUITS SHALL CONTAIN A GROUNDING CONDUCTOR, SIZED PER NEC/CEC REQUIREMENTS. L. THERE SHALL BE NO ROOF PENETRATIONS WITHIN 5'-0" OF FIRE RATED OR AREA SEPARATION WALLS. VERIFY EXACT LOCATIONS OF THESE WALLS WITH ARCHITECTURAL DRAWINGS. DISTRIBUTION PANEL SWITCHBOARD LUMINAIRE & SWITCH SYMBOLS LUMINAIRE - SEE SCHEDULE. MOTOR LUMINAIRE - SEE SCHEDULE. UNFUSED DISCONNECT SWITCH LUMINAIRE - SEE SCHEDULE. FUSED DISCONNECT SWITCH LUMINAIRE - SEE SCHEDULE. COMBINATION MAGNETIC STARTER/FUSED DISCONNECT SWITCH LUMINAIRE - POLE MOUNTED SINGLE HEAD. SEE SCHEDULE. MAGNETIC STARTER - NEMA SIZE INDICATED. LUMINAIRE - POLE MOUNTED DOUBLE HEAD. SEE SCHEDULE. MOTOR RATED SWITCH LUMINAIRE - SINGLE WALL WASHER. SEE SCHEDULE. T TRANSFORMER GROUND ROD LUMINAIRE - DOUBLE WALL WASHER. SEE SCHEDULE. LUMINAIRE - CORNER WALL WASHER. SEE SCHEDULE. LUMINAIRE - SEE SCHEDULE. LUMINAIRE - WALL MOUNTED. SEE SCHEDULE. LUMINAIRE - WALL MOUNTED. SEE SCHEDULE. G EMERGENCY GENERATOR CH 2 EQUIPMENT TAG POWER DISTRIBUTION SYMBOLS (SINGLE LINE) EMERGENCY LUMINAIRE - SEE SCHEDULE. CIRCUIT BREAKER - DRAW-OUT. EMERGENCY LUMINAIRE - SEE SCHEDULE. CIRCUIT BREAKER EMERGENCY LUMINAIRE - SEE SCHEDULE. FUSED SWITCH EMERGENCY LUMINAIRE - SEE SCHEDULE. M METER WITH CURRENT TRANSFORMER EMERGENCY LUMINAIRE - SEE SCHEDULE. TRANSFORMER EMERGENCY LUMINAIRE - SEE SCHEDULE. M. AUTOMATIC TRANSFER SWITCH EXIT LIGHT (WITH ARROW) - SEE SCHEDULE. O. DEMOLITION INFORMATION AND EXISTING EQUIPMENT AND DEVICE LOCATIONS AND QUANTITIES ARE THE RESULT OF PRELIMINARY FIELD INVESTIGATION ONLY AND DO NOT NECESSARILY REFLECT ALL DEVICES ON SITE THAT MAY EXIST OR MAY NEED TO BE DEMOLISHED. CONTRACTOR SHALL FIELD VERIFY ALL DEVICES, CONDUIT, WIRING, AND OTHER ITEMS WHICH MAY NEED TO BE RELOCATED, DEMOLISHED, OR PROTECTED IN PLACE AND SHALL MAKE PROVISIONS TO DO SO IN THEIR BID. EMERGENCY GENERATOR EXIT LIGHT (DOUBLE FACED WITH ARROW) - SEE SCHEDULE. EMERGENCY BATTERY PACK EXIT LIGHT - SEE SCHEDULE. GROUND ROD SINGLE POLE SWITCH - WALL MOUNTED AT + 48" AFF UON. OS OCCUPANCY SENSOR - CEILING MOUNTED SECURITY SYMBOLS O S OCCUPANCY SENSOR - WALL MOUNTED P PHOTOSENSOR LCD LCP TS A CARD READER ES ELECTRIC DOOR STRIKE GB GLASSBREAK DETECTOR M "A" DENOTES FIXTURE TYPE SAP A L1-3b "L1" DENOTES PANEL NAME "3" DENOTES CIRCUIT NUMBER "b" DENOTES SWITCHING LOWER CASE LETTER = SWITCH LEG D = DIMMER SWITCH. SEE SPECIFICATIONS K = KEY OPERATED SWITCH L = LOW VOLTAGE SWITCH M = MOMENTARY CONTACT SWITCH TS = DIGITAL WALL TIMER S = OCCUPANCY SENSOR SWITCH 3 = 3 WAY SWITCH 4 = 4 WAY SWITCH X D = DUAL TECHNOLOGY P = PASSIVE INFRARED U = ULTRASONIC RECEPTACLE SYMBOLS SINGLE RECEPTACLE - DESIGNATION AS NOTED. DUPLEX RECEPTACLE. GFCI DUPLEX RECEPTACLE. DOUBLE DUPLEX RECEPTACLE. DUPLEX RECEPTACLE - INSTALL AT + 1" ABOVE COUNTER TOP BACK SPLASH TO BOTTOM OF RECEPTACLE FACEPLATE UON. GFCI DUPLEX RECEPTACLE - INSTALL AT + 1" ABOVE COUNTER TOP BACK SPLASH TO BOTTOM OF RECEPTACLE FACEPLATE UON. FLUSH FLOOR BOX WITH DUPLEX RECEPTACLE, RJ45 DATA OUTLET, AND RJ11 TELEPHONE OUTLET. FLUSH FLOOR BOX WITH DUPLEX RECEPTACLE. SURFACE MOUNTED WIRE RACEWAY - INSTALL AT + 36" AFF UON. SIGNAL TERMINAL CABINET - FLUSH MOUNTED. SIGNAL TERMINAL CABINET - SURFACE MOUNTED. COMBINATION RJ11/BLANK TELEPHONE OUTLET - PROVIDE 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. "X" DENOTES QTY OF CABLES/JACKS. T. SEISMIC ANCHORAGE OF ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED IN ACCORDANCE WITH TITLE 24, CBC SECTION 1632A. U. THE DRAWINGS AND SPECIFICATIONS ARE FOR THE ASSISTANCE AND GUIDANCE OF THE CONTRACTOR. EXACT LOCATIONS, DISTANCES AND ELEVATIONS WILL BE GOVERNED BY ACTUAL CONDITIONS. COORDINATE THE CONTRACT DOCUMENTS AND FIELD CONDITIONS TO DETERMINE EXACT ROUTING AND FINAL TERMINATIONS FOR ALL WORK. SUFFICIENT ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRIC EQUIPMENT TO PERMIT READY AND SAFE ORPERATION AND MAINTENANCE OF SUCH EQUIPMENT PER CEC ARTICLE 110-26. WIRING & CONDUIT RUN SYMBOLS CONDUIT - CONCEALED IN WALLS OR CEILING. 7. 2013 CALIFORNIA GREEN CODE (PART 11, TITLE 24, CCR). 8. 2013 CALIFORNIA REFERENCED STANDARDS CODE (PART 12, TITLE 24, CCR). 9. NFPA 72 NATIONAL FIRE ALARM CODE. W. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE THE WORK OF ALL TRADES AND SUB-TRADES TO ENSURE THAT THE FINISHED PROJECT IS FULLY COMPLIANT WITH THE DESIGN INTENT OF THESE DOCUMENTS, INCLUDING, BUT NOT LIMITED TO, DIMENSIONS, ALIGNMENTS, REVEALS, CEILING HEIGHTS, PLACEMENT OF FIXTURES AND EQUIPMENT, AND PROPER, INTEGRATED OPERATION OF BUILDING SYSTEMS. X. ADDITIONAL CHARGES WILL NOT BE ACCEPTED BY THE OWNER FOR WORK THAT MUST BE ALTERED OR REDONE DUE TO IMPROPER COORDINATION OF THE WORK AMONG TRADES AND SUB-TRADES. Y. ALL DUCTS, PIPING AND CONDUITS SHALL BE CONCEALED UNLESS SPECIFICALLY NOTED. Z. ADDITIONAL SOFFITS OR CHASES, BEYOND THOSE INDICATED IN THIS DOCUMENTS, WILL NOT BE ALLOWED. F ESS I ON PRO AL V I D MA A I D ED E 19203 EXP. 6-30-16 E A TE LE C T R I CA L RN O F CA L I F O 10. NFPA 13 STANDARDS FOR FIRE SPRINKLER SYSTEMS. DRAWING INDEX E-1 GENERAL INFORMATION E-2 ELECTRICAL SPECIFICATIONS E-3 ELECTRICAL SPECIFICATIONS AND SCHEDULES E-4 SITE PLAN E-5 LEVELS 1 AND 2 ELECTRICAL DEMOLITION PLANS E-6 LEVELS 1 AND 2 LIGHTING DEMOLITION PLANS E-7 LEVELS 1 AND 2 LIGHTING PLANS E-8 E-9 LEVELS 1 AND 2 POWER PLANS SCHEDULES E-10 WIRING DIAGRAMS E-11 STANDARD DETAILS E-12 STANDARD DETAILS E-13 E-14 LUMINAIRE SCHEDULES AND T24 LUMINAIRE SCHEDULES AND T24 CONDUIT - FLEX WITH CONNECTION. CONDUIT - STUB UP. CONDUIT - STUB DOWN. CONDUIT - EMERGENCY POWER SYSTEM. AA. REFER TO TABLE BELOW FOR MAXIMUM ALLOWABLE DISTANCE FOR VARIOUS FEEDER AND BRANCH CIRCUIT WIRING SIZES. IF THE ALLOWABLE DISTANCE IS EXCEEDED, THE CONTRACTOR SHALL PROVIDE THE NEXT HIGHER WIRE SIZE UNTIL THE DISTANCE REQUIREMENTS NOTED BELOW ARE MET. CONDUIT - CAPPED. CONDUIT - CONTINUATION. NEW VS. EXISTING (N) CONDUIT - CONCEALED IN WALLS OR CEILING. (E) CONDUIT - CONCEALED IN WALLS OR CEILING. (E) CONDUIT - TO BE REMOVED. (N) FUSED DISCONNECT SWITCH (E) FUSED DISCONNECT SWITCH COMMUNICATIONS SYMBOLS CONDUIT AND WIRING ARE SHOWN ON THESE PLANS DIAGRAMMATICALLY. EXACT LOCATIONS SHALL BE DETERMINED IN THE FIELD TO SUIT SITE CONDITIONS. V. CONDUIT - HOME RUN TO PANEL, TERMINAL CABINET, ETC. SIZE CONDUIT ACCORDING TO SPECIFICATIONS AND APPLICABLE CODES. ALL 20A, 1P BRANCH CIRCUITS SHALL BE #12 AWG WIRES WITH #12 AWG NEUTRALS AND GROUNDS. RUN A MAXIMUM OF 3 BRANCH CIRCUITS PER CONDUIT. 2013 CALIFORNIA FIRE CODE (CFC) (PART 9,TITLE 24, CCR). THE CONTRACTOR SHALL BE RESPONSIBLE FOR SITE LOCATING ALL EXISTING UNDERGROUND SYSTEMS IN THE AREA OF UNDER GROUND WORK. REPAIR ALL DAMAGED SYSTEMS TO OWNERS SATISFACTION. MAINTAIN EXTREME CARE DURING TRENCHING AS EXISTING SYSTEMS ARE KNOWN TO EXIST IN THE AREA. PAN, TILT, ZOOM (PTZ) VIDEO CAMERA CONDUIT - DIRECT BURIAL. 6. R. FIXED POSITION VIDEO CAMERA CONDUIT - EXPOSED. 2013 CALIFORNIA ENERGY CODE (PART 6,TITLE 24, CCR). 12. ADA STANDARDS FOR ACCESSIBLE DESIGN - CODE OF REGULATIONS (INCLUDING AMENDMENTS). SECURITY ALARM PANEL Xx 5. VERIFY ALL VOLTAGES OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. KEYPAD MOTION DETECTOR 2013 CALIFORNIA PLUMBING CODE (CPC) (PART 5, TITLE 24, CCR). Q. S. TYPICAL LUMINAIRE & SWITCH NOMENCLATURE 4. 11. ADA STANDARDS FOR ACCESSIBLE DESIGN: ADA ACCESSIBILITY GUIDELINES (ADAAG) 28, PART 36 APPENDIX A. LIGHTING CONTROL PANEL KP 2013 CALIFORNIA MECHANICAL CODE (CMC) (PART 4, TITLE 24, CCR). PROVIDE A PULL CORD IN EVERY EMPTY CONDUIT FOR USE IN FUTURE CONSTRUCTION. DAYLIGHT CONTROL PANEL TIME SWITCH 3. P. ALARM CONTACT CR 2013 CALIFORNIA ELECTRICAL CODE (PART 3, TITLE 24, CCR). NEER AUXILIARY CONTACT - NORMALLY CLOSED. 2. ST THE CONTRACTOR SHALL, PRIOR TO BID, FIELD VERIFY ALL REQUIREMENTS FOR MODIFYING THE EXISTING DATA, TELEPHONE, POWER, AND LIGHTING SYSTEMS TO ACCOMMODATE ADDITIONS NOTED. PROVIDE ALL MATERIALS NEEDED TO MAKE A FULLY OPERATIONAL SYSTEM AT THE CONCLUSION OF PROJECT WORK. EXIT LIGHT - SEE SCHEDULE. 2013 CALIFORNIA BUILDING CODE (CBC), VOLUMES #1 AND #2 (PART 2,TITLE 24, CCR). NO EMERGENCY LUMINAIRE - WALL MOUNTED. SEE SCHEDULE. N. 1. GI EN AUXILIARY CONTACT - NORMALLY OPENED. CALIFORNIA CODES AND STANDARDS NOTE THAT BRANCH CIRCUIT WIRING IS NOT SHOWN. CIRCUIT NUMBERS ARE SHOWN ADJACENT TO ALL OUTLETS/FIXTURES/DEVICES. PROVIDE ALL BRANCH CIRCUIT WIRING BASED ON CIRCUIT NUMBERS SHOWN TO COMPLETE THE WIRING SYSTEM. EMERGENCY LUMINAIRE - WALL MOUNTED. SEE SCHEDULE. JUNCTION BOX KILOAMPERE INTERRUPTING CAPACITY KILOVOLT KILOVOLT AMPERE KILOWATT LIGHTING LOW VOLTAGE MAXIMUM THOUSAND CIRCULAR MILS MAIN DISTRIBUTION FRAME MECHANICAL MANHOLE MINIMUM MOUNTED MOUNTING NORMALLY CLOSED NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NOT IN ELECTRICAL CONTRACT NUMBER, NORMALLY OPEN NOT TO SCALE ON CENTER POLE PUBLIC ADDRESS PULL BOX POWER FACTOR PHASE PANEL POLYVINYL CHLORIDE EXISTING TO BE RELOCATED REQUIRED REQUIREMENT(S) ROOM RIGID STEEL CONDUIT SHEET SIGNAL TERMINAL CABINET SWITCH SWITCHBOARD TERMINAL CABINET TELEPHONE TYPICAL UNLESS OTHERWISE NOTED VOLT WATT, WIRE WEATHERPROOF TRANSFORMER Architecture Interiors Planning J JB KAIC KV KVA KW LTG LV MAX KCMIL MDF MECH MH MIN MTD MTG NC NFPA NIC NIEC NO NTS OC P PA PB PF PH PNL PVC (R) REQD REQT(S) RM RSC SHT STC SW SWBD TC TEL TYP UON V W WP XFMR IA "E1.0" DENOTES SHEET NUMBER. BLANK DENOTES SAME SHEET. AMPERE ABOVE AMPERE FRAME, AMPERE FUSE ABOVE FINISHED FLOOR AMPERE INTERRUPTING CAPACITY ARCHITECTURAL AMPERE SWITCH AMPERE TRIP AUTOMATIC TRANSFER SWITCH BREAKER BUILDING CONDUIT CABLE TELEVISION CIRCUIT BREAKER CALIFORNIA BUILDING CODE CANDELA CALIFORNIA ELECTRICAL CODE CALIFORNIA FIRE CODE CIRCUIT CENTER LINE CEILING CONDUIT ONLY COMMUNICATIONS CALIFORNIA STATE FIRE MARSHALL CENTER DEMOLISH DETAIL DIMENSION DISTRIBUTION DISTRIBUTION PANEL DRAWING EXISTING ELECTRICAL EMERGENCY ELECTRICAL METALLIC TUBING END OF LINE RESISTOR EQUIPMENT FIRE ALARM FIRE ALARM CONTROL PANEL FUTURE FINISH FLOOR GROUND HEIGHT HORSEPOWER INTERCOM INTERMEDIATE DISTRIBUTION FRAME INTERMEDIATE METAL CONDUIT ER WAP POWER DISTRIBUTION SYMBOLS (PLANS) SHEET NOTE TAG - SEE ASSOCIATED NOTE ON SAME SHEET. COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. MATERIALS AND EQUIPMENT SHALL BE U.L. AND CALIFORNIA STATE FIRE MARSHAL (CSFM) LISTED AND LABELED FOR THE APPLICATION. TELEVISION OUTLET - TYPE "F" BULKHEAD JACK. INSTALL AT + 52" AFF UON. PROVIDE 3/4" CONDUIT TO ABOVE ACCESSIBLE CEILING FOR CATV CABLE. TV SECTION OR ELEVATION DESIGNATION "2" DENOTES SECTION OR ELEVATION NUMBER 3 B. A ABV AF AFF AIC ARCH AS AT ATS BKR BLDG C CATV CB CBC CD CEC CFC CKT CL CLG CO COMM CSFM CTR (D) DET DIM DIST DP DWG (E) ELEC EM EMT EOL EQP FA FACP (F) FIN FL G, GND HGT HP IC IDF IMC FLUSH FLOOR BOX WITH MICROPHONE OUTLET WIRELESS ACCESS POINT, CEILING MOUNTED 2 E1.0 THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO BIDDING AND ALLOW FOR ALL FIELD CONDITIONS. OBTAIN CONTRACT DOCUMENTS FOR ALL OTHER TRADES AND BE RESPONSIBLE FOR ALL ELECTRICAL WORK NOTED AND CALLED OUT ON THE CONTRACT DOCUMENTS. COORDINATE ELECTRICAL WORK WITH ALL OTHER TRADES ON PROJECT. COORDINATE ALL CONDUIT RUNS, ELECTRICAL EQUIPMENT AND PANEL LOCATIONS WITH ALL OTHER WORK TO AVOID CONFLICTS. . "E2.1" DENOTES SHEET NUMBER. BLANK DENOTES SAME SHEET. A. ST 3 E2.1 PLAN OR DETAIL DESIGNATION "3" DENOTES DETAIL OR PLAN NUMBER ABBREVIATIONS J GENERAL SYMBOLS ELECTRICAL GENERAL NOTES REG I SYMBOL LIST (E) FUSED DISCONNECT SWITCH - TO BE REMOVED. VOLTAGE DROP FOR COMMON COPPER WIRE GAUGES AND CURRENT LOADS MAX FEEDER LENGTH - 3% VD (FT) MAX BRANCH CIRCUIT LENGTH - 2% VD (FT) WIRE SIZE CIRCUIT AMPS (A) 120V 208V 240V 277V 480V 120V 208V 12 16 46 80 93 107 185 69 10 24 48 83 96 111 192 72 8 32 58 99 115 132 229 6 40 73 127 146 169 4 52 89 154 178 206 240V 277V 480V 120 139 160 278 125 144 166 288 86 149 172 199 344 293 110 190 220 253 439 356 134 232 267 309 535 2 72 103 178 206 237 412 154 267 309 356 617 1/0 96 123 212 245 283 490 184 319 368 424 735 2/0 108 137 238 274 317 549 206 357 412 475 823 4/0 144 163 283 327 377 654 245 425 490 566 980 250 165 170 294 340 392 679 255 441 509 588 1019 300 184 181 314 362 418 725 272 471 543 627 1087 350 200 195 338 390 450 779 292 506 584 675 1169 500 248 224 388 448 517 896 336 582 672 776 1344 Revisions No. Description Date (N) LUMINAIRE - SEE SCHEDULE. (E) LUMINAIRE - SEE SCHEDULE. (E) LUMINAIRE - TO BE REMOVED. COMBINATION RJ11/RJ45 TELEPHONE/DATA OUTLET - PROVIDE 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. "X" DENOTES QTY OF CABLES/JACKS. COMBINATION RJ45/BLANK DATA OUTLET - PROVIDE 1" CONDUIT TO ABOVE ACCESSIBLE CEILING. "X" DENOTES QTY OF CABLES/JACKS. S SPEAKER - WALL MOUNTED. INSTALL AT + 8'-0" AFF UON. S SPEAKER - CEILING MOUNTED. C CLOCK - WALL MOUNTED. INSTALL AT + 8'-0" AFF UON. Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 POSITION. MANUFACTURERS: EATON, GENERAL ELECTRIC, SQUARE D, SIEMENS, OR APPROVED EQUIVALENT. ER Architecture Interiors Planning . ST J NEER D. PROVIDE NEMA 1 ENCLOSURE FOR INDOORS, NEMA 3R ENCLOSURE FOR OUTDOORS. MANUFACTURERS: EATON, GENERAL ELECTRIC, SQUARE D, SIEMENS, OR APPROVED EQUIVALENT. COMBINATION STARTERS: HEAVY DUTY, FUSIBLE OR NON-FUSIBLE TYPE (AS INDICATED ON DRAWINGS), DUAL RATED, QUICK-MAKE, QUICK-BREAK WITH FUSE REJECTION FEATURE FOR USE WITH CLASS R FUSES ONLY. DEVICE LABELED WITH MAXIMUM VOLTAGE, CURRENT, AND HORSEPOWER. PROVIDE COIL VOLTAGE COORDINATED WITH CONTROL REQUIREMENTS AND THERMAL OVERLOAD UNITS SIZED TO EQUIPMENT NAMEPLATE RATING. PROVIDE ONE N.C. AND ONE N.O. AUXILIARY CONTACTS. PROVIDE 3.3 DEMOLITION A. COORDINATE WITH OWNER SO THAT WORK CAN BE SCHEDULED NOT TO INTERRUPT OPERATIONS, NORMAL ACTIVITIES, BUILDING ACCESS, ACCESS TO DIFFERENT AREAS. THE OWNER WILL COOPERATE TO THE BEST OF THEIR ABILITY TO ASSIST IN A COORDINATED SCHEDULE, BUT WILL REMAIN THE FINAL AUTHORITY AS TO TIME OF WORK PERMITTED. B. COORDINATE THE EXACT LOCATION OF EXISTING UTILITIES AND EQUIPMENT PRIOR TO COMMENCEMENT OF WORK. COMPENSATE THE OWNER FOR DAMAGES CAUSED BY THE FAILURE TO LOCATE AND PRESERVE UTILITIES. REPLACE DAMAGED ITEMS WITH NEW MATERIAL TO MATCH EXISTING. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. C. EXECUTION: 1. REMOVE EXISTING LUMINAIRES, SWITCHES, RECEPTACLES, AND OTHER ELECTRICAL EQUIPMENT AND DEVICES AND ASSOCIATED WIRING FROM WALLS, CEILINGS, FLOORS, AND OTHER SURFACES SCHEDULED FOR REMODELING, RELOCATION, OR DEMOLITION UNLESS SHOWN AS RETAINED OR RELOCATED ON DRAWINGS. 2. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN ELECTRICAL CONTINUITY OF EXISTING SYSTEMS DURING CONSTRUCTION. REMOVE OR RELOCATE ELECTRICAL BOXES, CONDUIT, WIRING, EQUIPMENT, LUMINAIRES, AS ENCOUNTERED IN REMOVED OR REMODELED AREAS IN THE EXISTING CONSTRUCTION AFFECTED BY THIS WORK. 3. REMOVE AND RESTORE WIRING WHICH SERVES USABLE EXISTING OUTLETS CLEAR OF THE CONSTRUCTION OR DEMOLITION 4. IF EXISTING JUNCTION BOXES WILL BE MADE INACCESSIBLE, OR IF ABANDONED OUTLETS SERVE AS FEED THROUGH BOXES FOR OTHER EXISTING ELECTRICAL EQUIPMENT WHICH IS BEING RETAINED, PROVIDE NEW CONDUIT AND WIRE TO BYPASS THE ABANDONED OUTLETS. 5. IF EXISTING CONDUITS PASS THROUGH PARTITIONS OR CEILING WHICH ARE BEING REMOVED OR REMODELED, PROVIDE NEW CONDUIT AND WIRE TO REROUTE CLEAR OF THE CONSTRUCTION OR DEMOLITION AND MAINTAIN SERVICE TO THE EXISTING LOAD. 6. CONCEALED CONDUIT LOCATED IN CONCRETE WALLS OR HARDBOARD CEILING SPACES MAY BE ABANDONED IN PLACE. REMOVE CONDUCTORS AND TAG ABANDONED CONDUITS WITH CORRESPONDING SYSTEM AND TERMINATION POINT. CUT AND CAP ABANDONED CONDUIT. DO NOT EXTEND STUBS ABOVE FINISHED FLOOR. 7. EXTEND CIRCUITING AND DEVICES IN EXISTING WALLS TO BE FURRED OUT. 8. PROVIDE TEMPORARY SUPPORT FOR ELECTRICAL SYSTEMS THAT REMAIN IN PLACE. 9. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. 10. PROVIDE BLANK COVER PLATE FOR ABANDONED FLUSH OUTLETS. 11. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE. 12. PROVIDE UPDATED PANEL SCHEDULES AND DIRECTORIES THAT IDENTIFY EXISTING CIRCUITS AND NUMBER OF SPARE CIRCUITS AVAILABLE UPON COMPLETION OF DEMOLITION WORK. 13. OFFER REMOVED LUMINAIRES, WIRING DEVICES, PANELBOARDS, AND EQUIPMENT TO THE OWNER. IF OWNER CHOOSES TO RETAIN THESE ITEMS, RETURN SUCH ITEMS TO OWNER. CAREFULLY REMOVE AND DISPOSE OF ITEMS REJECTED BY OWNER FROM PROJECT SITE AND IN A LEGAL MANNER. 3.4 CONTINUITY OF SERVICE A. NO INTERRUPTION OF SERVICES TO ANY PART OF EXISTING FACILITIES WILL BE PERMITTED WITHOUT EXPRESS PERMISSION IN EACH INSTANCE FROM THE OWNER. REQUESTS FOR OUTAGES SHALL STATE THE SPECIFIC DATES AND HOURS AND THE MAXIMUM DURATIONS, WITH THE OUTAGES KEPT TO THESE SPECIFIC DATES AND HOURS AND THE MAXIMUM DURATIONS. OBTAIN WRITTEN PERMISSION FROM THE OWNER FOR ANY INTERRUPTION OF POWER, LIGHTING OR SIGNAL CIRCUITS AND SYSTEMS. 3.5 INSTALLATION A. INSTALL ELECTRICAL EQUIPMENT COMPLETE AS DIRECTED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS. OBTAIN INSTALLATION INSTRUCTIONS FROM MANUFACTURER PRIOR TO ROUGH-IN OF THE ELECTRICAL EQUIPMENT, EXAMINE THE INSTRUCTIONS THOROUGHLY. WHEN REQUIREMENTS OF INSTALLATION INSTRUCTIONS CONFLICT WITH CONTRACT DOCUMENTS, REQUEST CLARIFICATION FROM ARCHITECT PRIOR TO PROCEEDING WITH INSTALLATION. THIS INCLUDES PROPER INSTALLATION METHODS, SEQUENCING, AND COORDINATION WITH OTHER TRADES AND DISCIPLINES. B. DELIVERY, STORAGE AND HANDLING: INSPECT AND REPORT CONCEALED DAMAGE TO CARRIER WITHIN THEIR REQUIRED TIME PERIOD. STORE IN A CLEAN, DRY NO C. ELECTRIC, EATON, OR APPROVED EQUIVALENT. SAFETY SWITCHES: HEAVY DUTY, FUSIBLE AND NON-FUSIBLE TYPE (AS INDICATED ON DRAWINGS), DUAL RATED, QUICK-MAKE, QUICK-BREAK WITH FUSE REJECTION FEATURE FOR USE WITH CLASS R FUSES ONLY. DEVICE LABELED WITH MAXIMUM VOLTAGE, CURRENT, AND HORSEPOWER. OPERABLE HANDLE INTERLOCKED TO 3.2 MOTORS/APPLIANCE/UTILIZATION BRANCH CIRCUIT WIRING A. CONNECT EQUIPMENT, WHETHER FURNISHED BY OWNER OR OTHER DIVISIONS OF THE CONTRACT, ELECTRICALLY COMPLETE. DO NOT INSTALL ELECTRICAL EQUIPMENT OR WIRING ON MECHANICAL EQUIPMENT WITHOUT APPROVAL OF ARCHITECT. B. PROVIDE MOISTURE TIGHT EQUIPMENT WIRING AND SWITCHES IN DUCTS OR PLENUMS USED FOR ENVIRONMENTAL AIR. C. CONNECT MOTOR BRANCH CIRCUITS COMPLETE FROM PANEL TO MOTOR/EQUIPMENT AS REQUIRED BY CODE. D. MOTOR STARTERS FOR EQUIPMENT, MOTOR START CONTROL DEVICES, AND WIRING FURNISHED BY OTHER DIVISIONS PROVIDED BY EQUIPMENT INSTALLER FOR INSTALLATION BY THIS DIVISION, UNLESS NOTED ON DRAWINGS. E. INSTALL FEEDER CIRCUIT TO PACKAGED HVAC EQUIPMENT. TERMINATE FEEDER CONDUCTORS AT LINE TERMINALS AS DIRECTED BY EQUIPMENT MANUFACTURER. F. APPLIANCE/UTILIZATION EQUIPMENT: PROVIDE APPROPRIATE CABLE AND CORD CAP FOR FINAL CONNECTION UNLESS EQUIPMENT IS PROVIDED WITH SAME. VERIFY SPECIAL PURPOSE OUTLET NEMA CONFIGURATION AND AMPERE RATING WITH EQUIPMENT SUPPLIER PRIOR TO ORDERING DEVICES AND COVERPLATES. F ESS I ON PRO AL V I D MA A I D ED GI EN 2.6 WIRING DEVICES A. FINISH: STANDARD COLOR AS SELECTED BY THE ARCHITECT. B. WALL SWITCHES: DECORATIVE AC ROCKER SWITCHES CHARACTERISTICS: QUIET ACTING, 20 AMP, 120/277 VOLT, UL LISTED FOR MOTOR LOADS UP TO 80 PERCENT OF RATED AMPERAGE. WHERE SWITCHES ARE GANGED TOGETHER, PROVIDE A SINGLE MULTI-GANG COVERPLATE. COOPER, HUBBELL, LEVITON, PASS & SEYMOUR, OR APPROVED EQUIVALENT. C. RECEPTACLES: STRAIGHT PARALLEL BLADE, 125 VOLT, 2 POLE, 3 WIRE GROUNDING. 1. COMMERCIAL GRADE: RIVETED. BACK AND SIDE WIRED. BRASS GROUND CONTACT ON STEEL MOUNTING STRAP. NYLON FACE AND NYLON BASE. [20 AMP. COOPER 5362, HUBBELL 5362, BRYANT 5362, LEVITON 5362S, PASS & SEYMOUR 5362] [15 AMP. COOPER 5352, HUBBELL 5352, BRYANT 5352, LEVITON 5352, PASS & SEYMOUR 5352. D. GROUND FAULT INTERRUPTER (GFCI) RECEPTACLE: MEETS OR EXCEEDS UL943 (CLASS A GFCI), UL498. FEED THROUGH TYPE, BACK-AND-SIDE WIRED, TAMPER-RESISTANT, WEATHER RESISTANT SELF-TESTING, 20 AMP, 125VAC. HUBBELL GFR5362SB, COOPER WRVGF20, PASS & SEYMOUR 2095TRWR, OR APPROVED EQUIVALENT. E. COMBINATION TAMPER-RESISTANT COMMERCIAL-GRADE DUPLEX CONVENIENCE RECEPTACLES WITH (2) USB PORTS, 125 V, 20 A AND MINIMUM CHARGING OUTPUT OF 3.1 A. COMPLY WITH NEMA WD 1, NEMA WD 6 CONFIGURATION 5-20R, UL 498 SUPPLEMENT SD AND FEDERAL SPECIFICATION W-C-596. F. CONTROLLED CONVENIENCE RECEPTACLES, 125 V, 20 A: COMPLY WITH NEMA WD 1, NEMA WD 6 CONFIGURATION 5-20R, UL 498 AND FEDERAL SPECIFICATION W-C-596. MARKING PERMANENTLY PRINTED, MOLDED, OR STAMPED ON THE FACE OF THE RECEPTACLE AND IN COMPLIANCE WITH CONTROLLED RECEPTACLE MARKING REQUIREMENTS STATED IN ARTICLE 406.3(E) OF THE 2014 NATIONAL ELECTRICAL CODE. G. FINISH PLATES: COMMERCIAL GRADE THERMOPLASTIC, FINISH TO MATCH DEVICE FINISH. 2.7 SAFETY DISCONNECTS A. TOGGLE TYPE DISCONNECT SWITCHES: 120 VOLT, 1-POLE, 20 AMP, 1 HP MAXIMUM. NEMA 1 ENCLOSURE FOR INDOORS, NEMA 3R ENCLOSURE FOR OUTDOORS. B. MANUAL MOTOR STARTERS: QUICK-MAKE, QUICK-BREAK. THERMAL OVERLOAD PROTECTION. DEVICE LABELED WITH MAXIMUM VOLTAGE, CURRENT, AND HORSEPOWER. PART 3 - EXECUTION 3.1 EXAMINATION A. DRAWINGS ARE DIAGRAMMATIC WITH SYMBOLS REPRESENTING ELECTRICAL EQUIPMENT, OUTLETS, LUMINAIRES, AND WIRING. EXAMINE THE ENTIRE SET OF DRAWINGS TO AVOID CONFLICTS WITH OTHER SYSTEMS. DETERMINE EXACT ROUTE AND INSTALLATION OF ELECTRICAL WIRING AND EQUIPMENT WITH CONDITIONS OF CONSTRUCTION. B. CLARIFICATION: 1. THE DRAWINGS GOVERN IN MATTERS OF QUANTITY, THE SPECIFICATION IN MATTERS OF QUALITY. IN EVENT OF CONFLICT ON DRAWINGS OR IN THE SPECIFICATIONS, THE GREATER QUANTITY AND THE HIGHER QUALITY APPLY. 2. SHOULD THE ELECTRICAL DOCUMENTS INDICATE A CONDITION CONFLICTING WITH THE GOVERNING CODES AND REGULATIONS, REFRAIN FROM INSTALLING THAT PORTION OF THE WORK UNTIL CLARIFIED BY ARCHITECT. E 19203 EXP. 6-30-16 E A TE LE C T R I CA L IA ENVIRONMENT. MAINTAIN FACTORY PACKAGING, AND IF REQUIRED, PROVIDE AN ADDITIONAL HEAVY CANVAS OR HEAVY PLASTIC COVER TO PROTECT ENCLOSURE(S) FROM DIRT, WATER, CONSTRUCTION DEBRIS, AND TRAFFIC. C. INSTALL EQUIPMENT REQUIRING ACCESS (I.E. JUNCTION BOXES, LUMINAIRES, POWER SUPPLIES, MOTORS, ETC.) SO THAT THEY MAY BE SERVICED, RESET, REPLACED OR RECALIBRATED BY SERVICE PEOPLE WITH NORMAL SERVICE TOOLS AND EQUIPMENT. DO NOT INSTALL ELECTRICAL EQUIPMENT IN OBVIOUS PASSAGES, DOORWAYS, SCUTTLES OR CRAWL SPACES WHICH WOULD IMPEDE OR BLOCK THE INTENDED USAGE. D. NOISE CONTROL: 1. DO NOT INSTALL OUTLET BOXES BACK TO BACK. DO NOT USE STRAIGHT THROUGH BOXES. 2. DO NOT PLACE CONTACTORS, TRANSFORMERS, STARTERS AND SIMILAR NOISE PRODUCING DEVICES ON WALLS WHICH ARE COMMON TO OCCUPIED SPACES UNLESS SPECIFICALLY CALLED FOR ON DRAWINGS. WHERE SUCH DEVICES MUST BE MOUNTED ON WALLS COMMON TO OCCUPIED SPACES, MOUNT OR ISOLATE IN SUCH A MANNER AS TO EFFECTIVELY PREVENT THE TRANSMISSION OF THEIR INHERENT NOISE TO THE OCCUPIED SPACE. E. FIRESTOPPING: COORDINATE LOCATION AND PROTECTION LEVEL OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS, AND FLOORS. WHEN THESE ASSEMBLIES ARE PENETRATED, SEAL AROUND CONDUIT AND EQUIPMENT WITH APPROVED FIRESTOPPING MATERIAL. INSTALL FIRESTOPPING MATERIAL COMPLETE AS DIRECTED THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. MEET REQUIREMENTS OF ASTM E814, STANDARD TEST METHOD FOR FIRE TESTS OF THROUGH-PENETRATION FIRE STOPS. F. CONDUIT: 1. CONDUIT JOINTS: ASSEMBLE CONDUITS CONTINUOUS AND SECURE TO BOXES, PANELS, LUMINAIRES AND EQUIPMENT WITH FITTINGS TO MAINTAIN CONTINUITY. 2. CONCEAL CONDUITS. EXPOSED CONDUITS ARE PERMITTED ONLY IN THE FOLLOWING AREAS: a. MECHANICAL ROOMS, ELECTRICAL ROOMS OR SPACES WHERE WALLS, CEILINGS AND FLOORS WILL NOT BE COVERED WITH FINISHED MATERIALS. b. EXISTING WALLS THAT ARE CONCRETE OR BLOCK CONSTRUCTION AND WHERE SPECIFICALLY NOTED ON THE DRAWINGS. 3. DO NOT INSTALL CONDUITS ON OR ACROSS FLOORS. WHERE EXPOSED CONDUITS ARE PERMITTED, INSTALL PARALLEL AND PERPENDICULAR TO WALLS, TIGHT TO FINISHED SURFACES AND NEATLY OFFSET INTO BOXES. 4. KEEP CONDUITS A MINIMUM OF 12-INCHES AWAY FROM STEAM OR HOT WATER RADIANT HEATING LINES (AT OR ABOVE 104 DEGREES F) OR 3-INCHES AWAY FROM WASTE OR WATER LINES. 5. KEEP 277/480 VOLT WIRING INDEPENDENT OF 120/208 VOLT WIRING. KEEP POWER WIRING INDEPENDENT OF COMMUNICATION SYSTEM WIRING. KEEP EMERGENCY SYSTEM WIRING INDEPENDENT OF OTHER WIRING SYSTEMS. 6. MAXIMUM BENDS: INSTALL NO MORE THAN EQUIVALENT OF THREE 90 DEGREE BENDS BETWEEN ELECTRICAL BOXES. INSTALL NO MORE THAN EQUIVALENT OF TWO 90 DEGREE BENDS BETWEEN TELECOMMUNICATION BOXES. USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS. 7. FLEXIBLE CONDUIT: INSTALL 12 INCH MINIMUM SLACK LOOP ON FLEXIBLE METALLIC CONDUIT AND LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. 8. CONDUIT SIZE: MINIMUM TRADE SIZE 3/4 INCH. 9. CONDUIT USE LOCATIONS: a. DRY, PROTECTED: RMC, IMC, EMT. b. FOR SECURITY CONDUITS INSTALLED EXPOSED AND SUBJECT TO TAMPERING: RMC. c. IN AREAS EXPOSED TO SEVERE MECHANICAL DAMAGE: RMC. d. SHARP BENDS AND ELBOWS: RMC, EMT USE FACTORY ELBOWS. e. INSTALL TWO PULL STRINGS/TAPES IN EMPTY RACEWAYS. SECURE PULL STRINGS/TAPES AT EACH END. f. ELBOW FOR LOW ENERGY SIGNAL SYSTEMS: USE LONG RADIUS FACTORY ELLS WHERE LINKING SECTIONS OF RACEWAY FOR INSTALLATION OF SIGNAL CABLE. g. FOR MOTORS, RECESSED LUMINAIRES AND EQUIPMENT CONNECTIONS SUBJECT TO MOVEMENT OR VIBRATION, USE FLEXIBLE METALLIC CONDUIT. h. FOR MOTORS AND EQUIPMENT CONNECTIONS SUBJECT TO MOVEMENT OR VIBRATION AND SUBJECTED TO THE FOLLOWING CONDITIONS; EXTERIOR LOCATION, MOIST OR HUMID ATMOSPHERE, WATER SPRAY, OIL OR GREASE: USE PVC COATED LIQUID TIGHT FLEXIBLE METALLIC CONDUIT. G. CONDUIT FITTINGS: 1. USE SET SCREW TYPE FITTINGS ONLY IN DRY LOCATIONS. WHEN SET SCREW FITTINGS ARE UTILIZED, PROVIDE INSULATED CONTINUOUS EQUIPMENT GROUND CONDUCTOR IN CONDUIT, FROM OVER CURRENT PROTECTION DEVICE TO OUTLET. 2. USE COMPRESSION FITTINGS IN DRY LOCATIONS, DAMP AND RAIN-EXPOSED LOCATIONS. MAXIMUM SIZE PERMITTED IN DAMP LOCATIONS AND LOCATIONS EXPOSED TO RAIN IS 2 INCHES IN DIAMETER. 3. PROVIDE CORROSION-RESISTANT PUNCHED-STEEL BOX KNOCKOUT CLOSURES, CONDUIT LOCKNUTS AND PLASTIC CONDUIT BUSHINGS OF THE TYPE AND SIZE TO SUIT EACH RESPECTIVE USE AND INSTALLATION. 4. USE INSULATED TYPE BUSHINGS WITH GROUND PROVISION AT SWITCHBOARDS, PANELBOARDS, SAFETY DISCONNECT SWITCHES, JUNCTION BOXES AND THE LIKE THAT HAVE FEEDERS 60 AMPERES AND GREATER. 5. PROVIDE CONDUIT EXPANSION FITTINGS AT BUILDING EXPANSION JOINTS AND AT LOCATIONS WHERE CONDUIT IS EXPOSED TO THERMAL EXPANSION AND CONTRACTION. H. WIRES AND CABLES: 1. CONDUCTOR INSTALLATION: INSTALL CONDUCTORS WITH CARE TO AVOID DAMAGE TO INSULATION. DO NOT APPLY GREATER TENSION ON CONDUCTORS THAN RECOMMENDED BY MANUFACTURER DURING INSTALLATION. 2. CONDUCTOR SIZE AND QUANTITY: INSTALL NO CONDUCTORS SMALLER THAN 12AWG UNLESS OTHERWISE SHOWN. PROVIDE REQUIRED CONDUCTORS FOR A FULLY OPERABLE SYSTEM. I. BOXES: 1. ANCHORING: SECURE BOXES RIGIDLY TO THE SUBSTRATE UPON WHICH THEY ARE BEING MOUNTED, OR SOLIDLY EMBED BOXES IN CONCRETE OR MASONRY. 2. NOISE CONTROL: PROVIDE ACOUSTIC PUTTY PAD TO BACK SIDE OF EACH OUTLET BOX INSTALLED IN ACOUSTIC RATED WALLS. 3. COORDINATE ELECTRICAL DEVICE LOCATIONS AND ELEVATIONS (SWITCHES AND RECEPTACLES) WITH ARCHITECTURAL DRAWINGS TO PREVENT MOUNTING DEVICES IN MIRRORS, BACK SPLASHES, AND BEHIND CABINETS. 4. PROVIDE WEATHERPROOF OUTLETS FOR LOCATIONS EXPOSED TO WEATHER OR MOISTURE. 5. KNOCKOUT CLOSURES: PROVIDE KNOCKOUT CLOSURES TO CAP UNUSED KNOCKOUT HOLES WHERE BLANKS HAVE BEEN REMOVED. 6. CODE COMPLIANCE: COMPLY WITH CEC AS APPLICABLE TO CONSTRUCTION AND INSTALLATION OF ELECTRICAL BOXES AND FITTINGS AND SIZE BOXES ACCORDING TO CEC, EXCEPT AS NOTED OTHERWISE. 7. MOUNT CENTER OF OUTLET BOXES AS REQUIRED BY AMERICANS WITH DISABILITIES ACT (ADA), OR NOTED ON DRAWINGS, THE FOLLOWING DISTANCE ABOVE THE FLOOR: a. CONTROL SWITCHES: 46 INCHES. b. RECEPTACLES: 18 INCHES. c. WALL PHONES: 46 INCHES. d. TELECOM OUTLETS: 18 INCHES. e. OTHER OUTLETS: AS INDICATED IN OTHER SECTIONS OF SPECIFICATIONS OR AS DETAILED ON DRAWINGS. J. PROVIDE CEC-REQUIRED DISCONNECT SWITCHES WHETHER SPECIFICALLY SHOWN ON DRAWINGS OR NOT. PROVIDE DISCONNECT SWITCH AT EACH MOTOR LOCATION WITHIN 5 FEET UNLESS OTHERWISE NOTED. LOCATE DISCONNECT MEANS IN VIEW OF AND NOT INSIDE OF EQUIPMENT, SUCH THAT TOOLS ARE NOT NEEDED TO REMOVE COVERS OF ENERGIZED EQUIPMENT TO ACCESS THE DISCONNECTING MEANS. COORDINATE FUSE AMPERE RATING WITH INSTALLED EQUIPMENT. FUSE AMPERE RATING VARIANCE BETWEEN ORIGINAL DESIGN INFORMATION AND INSTALLED EQUIPMENT, SIZE IN ACCORDANCE WITH BUSSMANN FUSETRON 40C RECOMMENDATIONS. DO NOT PROVIDE FUSES OF LOWER AMPERE RATING THAN MOTOR STARTER THERMAL UNITS. PROVIDE ARC FLASH LABELS. K. SUPPORTING DEVICES: 1. SAFETY FACTOR OF 4 REQUIRED FOR EVERY FASTENING DEVICE OR SUPPORT FOR ELECTRICAL EQUIPMENT INSTALLED. SUPPORT TO WITHSTAND FOUR TIMES WEIGHT OF EQUIPMENT IT SUPPORTS. PROVIDE SEISMIC BRACING PER CBC REQUIREMENTS FOR THIS BUILDING LOCATION. 2. PROVIDE VERTICAL SUPPORT MEMBERS FOR EQUIPMENT AND LUMINAIRES, STRAIGHT AND PARALLEL TO BUILDING WALLS. PROVIDE HORIZONTAL SUPPORT MEMBERS STRAIGHT AND PARALLEL TO CEILINGS OR FINISHED FLOOR, UNLESS OTHERWISE NOTED. 3. PROVIDE INDEPENDENT SUPPORTS TO STRUCTURAL MEMBER FOR LUMINAIRES, ELECTRICAL MATERIALS, OR EQUIPMENT INSTALLED IN OR ON CEILING, WALLS OR IN VOID SPACES OR OVER FURRED OR SUSPENDED CEILINGS. 4. DO NOT USE OTHER TRADE'S FASTENING DEVICES AS SUPPORTING MEANS FOR LUMINAIRES, ELECTRICAL MATERIALS, OR EQUIPMENT. 5. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT OR CONDUIT. 6. DO NOT USE SUPPORTS OR FASTENING DEVICES TO SUPPORT OTHER THAN ONE PARTICULAR ITEM. 7. SUPPORT CONDUITS WITHIN 18 INCHES OF OUTLETS, BOXES, PANELS, CABINETS AND DEFLECTIONS. MAXIMUM DISTANCE BETWEEN SUPPORTS NOT TO EXCEED 8 FOOT SPACING. 8. SUPPORT FLEXIBLE CONDUITS AND MC CABLE WITHIN 12 INCHES OF OUTLETS, BOXES, PANELS, CABINETS AND DEFLECTIONS. MAXIMUM DISTANCE BETWEEN SUPPORTS NOT TO EXCEED 4 FOOT SPACING. 9. SECURELY SUSPEND JUNCTION BOXES, PULL BOXES OR OTHER CONDUIT TERMINATING HOUSINGS LOCATED ABOVE SUSPENDED CEILING FROM THE FLOOR ABOVE OR ROOF STRUCTURE TO PREVENT SAGGING AND SWAYING. 10. PROVIDE SEISMIC BRACING PER CBC REQUIREMENTS. L. ELECTRICAL IDENTIFICATION: 1. CONDUCTOR IDENTIFICATION: APPLY MARKERS ON EACH CONDUCTOR FOR POWER, CONTROL, SIGNALING AND COMMUNICATIONS CIRCUITS. 2. PROVIDE AN ENGRAVED LABEL ON EACH MAJOR UNIT OF ELECTRICAL EQUIPMENT INDICATING BOTH EQUIPMENT NAME AND CIRCUIT SERVING EQUIPMENT, INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: DISCONNECT SWITCHES, RELAYS, CONTACTORS, TIME SWITCHES, OVERRIDE SWITCHES, SERVICE DISCONNECTS, DISTRIBUTION SWITCHES, SWITCHBOARDS, BRANCH CIRCUIT PANELBOARDS, AND TRANSFORMERS. 3. INSTALL ENGRAVED LABEL ON THE INSIDE OF FLUSH PANELS, VISIBLE WHEN DOOR IS OPENED. INSTALL LABEL ON OUTSIDE OF SURFACE PANEL. SECURE NAMEPLATES TO INSIDE SURFACE OF DOOR ON PANELBOARD THAT IS RECESSED IN FINISHED LOCATIONS. 4. ON THE BACK OF RECEPTACLE AND SWITCH FINISH PLATES LEGIBLY WRITE WITH INDELIBLE INK PEN THE CIRCUIT THAT EACH DEVICE IS CONNECTED TO. M. GROUNDING: 1. PERFORMANCE REQUIREMENTS: SUPPLEMENT THE GROUNDED NEUTRAL OF THE SECONDARY DISTRIBUTION SYSTEM WITH AN EQUIPMENT GROUNDING SYSTEM TO PROPERLY SAFEGUARD THE EQUIPMENT AND PERSONNEL. INSTALL EQUIPMENT GROUNDING SUCH THAT METALLIC STRUCTURES, ENCLOSURES, RACEWAYS, JUNCTION BOXES, OUTLET BOXES, CABINETS, MACHINE FRAMES, PORTABLE EQUIPMENT AND OTHER CONDUCTIVE ITEMS IN CLOSE PROXIMITY WITH ELECTRICAL CIRCUITS OPERATE CONTINUOUSLY AT GROUND POTENTIAL AND PROVIDE A LOW IMPEDANCE PATH FOR POSSIBLE GROUND FAULT CURRENTS. 2. RACEWAY GROUNDING: a. GROUND METALLIC RACEWAY SYSTEMS. BOND TO GROUND TERMINAL WITH CODE SIZE JUMPER EXCEPT WHERE CODE SIZE OR LARGER GROUNDING CONDUCTOR IS INCLUDED WITH CIRCUIT, USE GROUNDING BUSHING WITH LAY-IN LUG. b. CONNECT METAL RACEWAYS, WHICH TERMINATE WITHIN AN ENCLOSURE BUT WITHOUT MECHANICAL CONNECTION TO THE ENCLOSURE, BY GROUNDING BUSHINGS AND GROUND WIRE TO THE GROUNDING BUS. c. WHERE EQUIPMENT SUPPLY CONDUCTORS ARE IN FLEXIBLE METALLIC CONDUIT, INSTALL STRANDED COPPER EQUIPMENT GROUNDING CONDUCTOR FROM OUTLET BOX TO EQUIPMENT FRAME. d. INSTALL EQUIPMENT GROUNDING CONDUCTOR, CODE SIZE MINIMUM IN NONMETALLIC AND METALLIC RACEWAY SYSTEMS. 3. BOXES, CABINETS, ENCLOSURES AND PANELBOARDS: a. BOND GROUNDING CONDUCTORS TO ENCLOSURE WITH SPECIFIED CONDUCTORS AND LUGS. INSTALL LUGS ONLY ON THOROUGHLY CLEANED CONTACT SURFACES. b. BOND SECTIONS OF SERVICE EQUIPMENT ENCLOSURE TO SERVICE GROUND BUS. 4. PROVIDE TELECOMMUNICATIONS GROUNDING BAR AT EACH TELECOMMUNICATIONS BACKBOARD. MOUNT TELECOMMUNICATIONS GROUNDING BAR 84-INCHES ABOVE FINISHED FLOOR, JUST BELOW OVERHEAD CABLE RUNWAY. BOND THE GROUNDING BAR TO SERVICE GROUNDING BAR IN THE MAIN SERVICE EQUIPMENT WITH A 6AWG COPPER EQUIPMENT GROUNDING CONDUCTOR. 5. MOTORS, EQUIPMENT AND APPLIANCES: INSTALL CODE SIZE EQUIPMENT GROUNDING CONDUCTOR FROM OUTLET BOX TO (MOTOR) EQUIPMENT FRAME OR MANUFACTURER'S DESIGNATED GROUND TERMINAL. 6. RECEPTACLES: CONNECT GROUND TERMINAL OF RECEPTACLE TO EQUIPMENT GROUND SYSTEM BY NO. 14 CONDUCTOR BOLTED TO OUTLET BOX. SELF GROUNDING NATURE OF RECEPTACLE DEVICES DOES NOT ELIMINATE CONDUCTOR BOLTED TO OUTLET BOX. N. FUSES: FOR EACH CLASS AND AMPERE RATING OF FUSE INSTALLED, PROVIDE THREE SPARE FUSES. O. CONTROL DEVICES: 1. CONTACTORS: a. PROVIDE VIBRATION ISOLATION MOUNTING PADS FOR ELECTRICALLY HELD CONTACTORS INSTALLED WITHIN OR ON WALLS WHICH ARE COMMON TO OCCUPIED SPACES. ISOLATE TERMINALS AND OPERATING MECHANISMS FROM ENCLOSURE. b. INSTALL CONTACTORS AND RELAYS TO REDUCE NOISE SUCH THAT IT WILL NOT CREATE A DISTURBANCE OR DISTRACTION IN THE AREAS IN WHICH SUCH EQUIPMENT IS LOCATED. 2. EMERGENCY RELAY (UL924): a. PROVIDE UNSWITCHED EMERGENCY CIRCUIT, AND UNSWITCHED AND SWITCHED NORMAL CIRCUIT TO UL924 RELAY FOR CONTROL OF EMERGENCY LUMINAIRES WITH REMAINING ROOM LUMINAIRES ON NORMAL POWER. b. INSTALL EACH RELAY WITHIN DEDICATED 4-11/16-INCH JUNCTION BOX WITH DOUBLE-GANG PLASTER RING FOR WALL OR CEILING FLUSH-MOUNT AS INDICATED ON DRAWINGS. WHERE LOCATION IN CEILING WOULD INTERFERE WITH REMOVAL OF CEILING TILES, INSTALL RELAY FLUSH-MOUNTED IN NEAREST WALL AT CEILING LEVEL. DO NOT LOCATE BEHIND WALL SWITCH. P. LIGHTING: 1. INSTALL LUMINAIRES SECURELY, IN NEAT AND WORKMANLIKE MANNER. 2. INSTALL LUMINAIRE OF TYPES INDICATED WHERE SHOWN AND AT INDICATED HEIGHTS; IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT LUMINAIRES COMPLY WITH REQUIREMENTS AND SERVE INTENDED PURPOSES. 3. ALIGN, MOUNT AND LEVEL LUMINAIRES UNIFORMLY. USE BALL HANGERS FOR SUSPENDED STEM MOUNTED LUMINAIRES. 4. AVOID INTERFERENCE WITH AND PROVIDE CLEARANCE FOR EQUIPMENT. WHERE THE INDICATED LOCATIONS FOR THE LUMINAIRES CONFLICT WITH LOCATIONS FOR EQUIPMENT, CHANGE LOCATIONS FOR THE LUMINAIRE AS DIRECTED BY ARCHITECT. 5. SUSPENDED LUMINAIRES: MOUNTING HEIGHTS INDICATE CLEARANCES BETWEEN BOTTOM OF LUMINAIRE AND FINISHED FLOORS. 6. SUPPORT LUMINAIRES: ANCHOR SUPPORTS TO STRUCTURAL SLAB OR TO STRUCTURAL MEMBERS WITHIN A PARTITION, OR ABOVE A SUSPENDED CEILING. MAINTAIN LUMINAIRE POSITIONS AFTER CLEANING AND RELAMPING. SUPPORT LUMINAIRES WITHOUT CAUSING CEILING OR PARTITION TO DEFLECT. 7. PROVIDE RECESSED FLUORESCENT LUMINAIRES WITH TWO SUPPORT WIRES AS REQUIRED BY CBC. 8. WIRING: a. RECESSED LUMINAIRES TO BE INSTALLED USING FLEXIBLE METALLIC CONDUIT WITH LUMINAIRE CONDUCTORS SPLICED TO BRANCH CIRCUIT CONDUCTORS IN NEARBY ACCESSIBLE JUNCTION BOX OVER CEILING. JUNCTION BOX FASTENED TO BUILDING STRUCTURAL MEMBER WITHIN 6 FEET OF LUMINAIRE. b. INSTALL LUMINAIRES FOR LIFT OUT AND REMOVAL FROM CEILING PATTERN WITHOUT DISCONNECTING CONDUCTORS OR DEFACING CEILING MATERIALS. c. FLEXIBLE CONNECTIONS WHERE PERMITTED TO EXPOSED LUMINAIRES; NEAT AND STRAIGHT, WITHOUT EXCESS SLACK, ATTACHED TO SUPPORT DEVICE. d. INSTALL JUNCTION BOX, FLEXIBLE CONDUIT AND HIGH TEMPERATURE INSULATED CONDUCTORS FOR THROUGH WIRING OF RECESSED LUMINAIRES. 9. RELAMP LUMINAIRES WHICH HAVE FAILED LAMPS AT SUBSTANTIAL COMPLETION. 10. REPLACE BALLASTS DEEMED AS EXCESSIVELY NOISY BY ARCHITECT, ENGINEER, OR OWNER. 11. INSTALL SUSPENDED LUMINAIRES AND EXIT SIGNS USING PENDANTS SUPPORTED FROM SWIVEL HANGERS. PROVIDE PENDANT LENGTH REQUIRED TO SUSPEND LUMINAIRE AT INDICATED HEIGHT. 12. INSTALL SURFACE MOUNTED LUMINAIRES AND EXIT SIGNS PLUMB AND ADJUST TO ALIGN WITH BUILDING LINES AND WITH EACH OTHER. SECURE TO PREVENT MOVEMENT. 13. MAKE WIRING CONNECTIONS TO BRANCH CIRCUIT USING BUILDING WIRE WITH INSULATION SUITABLE FOR TEMPERATURE CONDITIONS WITHIN LUMINAIRE. 14. WHERE REMOTE BALLASTS OR DRIVERS ARE REQUIRED, INSURE ADEQUATE ACCESSIBILITY. UPSIZE CONDUCTORS BETWEEN LUMINAIRE AND BALLAST/DRIVER TO ACCOMMODATE VOLTAGE DROP. ST PART 1 GENERAL 1.1 SUMMARY A. ELECTRICAL SYSTEMS REQUIRED FOR THIS WORK INCLUDES LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY TO COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN ON DRAWINGS, SPECIFIED HEREIN OR REQUIRED FOR A COMPLETE OPERABLE FACILITY AND NOT SPECIFICALLY DESCRIBED IN OTHER SECTIONS OF THESE SPECIFICATIONS. AMONG THE ITEMS REQUIRED ARE: 1. DISTRIBUTION EQUIPMENT SHOWN ON DRAWINGS. 2. FEEDERS TO DISTRIBUTION PANELS, HEATING, VENTILATING AND AIR CONDITIONING (HVAC) EQUIPMENT, OWNER-PROVIDED EQUIPMENT, AND OTHER EQUIPMENT AS DETAILED. 3. BRANCH CIRCUIT WIRING FROM THE DISTRIBUTION PANELS FOR LIGHTING, RECEPTACLES, MOTORS, AND OTHER DETAILED CIRCUIT WIRING. 4. LUMINAIRES, CONTROL SWITCHES, RECEPTACLES, RELAYS, SUPPORTS AND OTHER ACCESSORY ITEMS. 5. WIRING AND POWER CONNECTIONS FOR MOTORS INSTALLED FOR HEATING, COOLING AND VENTILATION. 6. ARC-FLASH HAZARD ANALYSIS B. FEES: 1. OBTAIN AND PAY FOR ELECTRICAL PERMITS, PLAN REVIEW, AND INSPECTIONS FROM LOCAL AUTHORITY HAVING JURISDICTION (AHJ). 1.2 DEFINITIONS A. FOLLOWING IS A LIST OF ABBREVIATIONS GENERALLY USED IN THIS DIVISION: 1. ADA AMERICANS WITH DISABILITIES ACT. 2. AHJ AUTHORITY HAVING JURISDICTION. 3. CBC CALIFORNIA BUILDING CODE. 4. CEC CALIFORNIA ELECTRICAL CODE. 5. CFC CALIFORNIA FIRE CODE. 6. CEC T24 CALIFORNIA ENERGY CODE TITLE 24. 7. HVAC HEATING, VENTILATING AND AIR CONDITIONING. 8. IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS. 9. IES ILLUMINATING ENGINEERING SOCIETY 10. LEED LEADERSHIP IN ENERGY AND ENVIRONMENTAL DESIGN 11. NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 12. NFPA NATIONAL FIRE PROTECTION ASSOCIATION. 13. OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION. 14. UL UNDERWRITERS LABORATORIES INC. 15. USGBC UNITED STATES GREEN BUILDING COUNCIL B. PROVIDE: TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. C. FURNISH: SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNPACKING, ASSEMBLY AND INSTALLATION. D. INSTALL: INCLUDES UNLOADING, UNPACKING, ASSEMBLING, ERECTING, INSTALLATION, APPLYING, FINISHING, PROTECTING, CLEANING AND SIMILAR OPERATIONS AT THE PROJECT SITE AS REQUIRED TO COMPLETE ITEMS OF WORK FURNISHED BY OTHERS. 1.3 SUBMITTALS A. OPERATION AND MAINTENANCE DOCUMENTATION: PROVIDE COPIES OF CERTIFICATES OF CODE AUTHORITY ACCEPTANCE, TEST DATA, PRODUCT DATA, GUARANTEES, WARRANTIES, AND THE LIKE. B. SHOP DRAWINGS: PROVIDE SHOP DRAWINGS WHICH INCLUDE PHYSICAL CHARACTERISTICS, ELECTRICAL CHARACTERISTICS, DEVICE LAYOUT PLANS, WIRING DIAGRAMS, AND THE LIKE. PROVIDE PRODUCT SUBMITTALS AND SHOP DRAWINGS IN EITHER PAPER FORMAT OR ELECTRONIC FORMAT. ELECTRONIC FORMAT MUST BE SUBMITTED VIA EMAIL OR FTP SITE. FOR PAPER HARDCOPY, PROVIDE ONE COMPLETE BINDER WITH TABBED DIVIDERS CONTAINING A SEPARATE SUBMITTAL FOR EACH SPECIFICATIONS SECTION. FOR ELECTRONIC FORMAT, PROVIDE ONE ZIP FILE PER SPECIFICATION DIVISION CONTAINING A SEPARATE FILE FOR EACH SPECIFICATIONS SECTION. INDIVIDUAL SUBMITTALS SENT PIECEMEAL IN A PER SPECIFICATION SECTION METHOD WILL BE RETURNED WITHOUT REVIEW OR COMMENT. COPY ARCHITECT ON ALL SUBMISSIONS. 1. IDENTIFY EACH SUBMITTAL IN DETAIL. NOTE WHAT DIFFERENCES, IF ANY, EXIST BETWEEN THE SUBMITTED ITEM AND THE SPECIFIED ITEM. FAILURE TO IDENTIFY THE DIFFERENCES WILL BE CONSIDERED CAUSE FOR DISAPPROVAL. IF DIFFERENCES ARE NOT IDENTIFIED AND/OR NOT DISCOVERED DURING THE SUBMITTAL REVIEW PROCESS, CONTRACTOR REMAINS RESPONSIBLE FOR PROVIDING EQUIPMENT AND MATERIALS THAT MEET THE SPECIFICATIONS AND DRAWINGS. 2. PROVIDE THE FOLLOWING INFORMATION FOR LIGHTING SUBMITTALS: INCLUDE ELECTRICAL RATINGS, DIMENSIONS, MOUNTING, MATERIAL, REQUIRED CLEARANCES, TERMINATIONS, WIRING AND CONNECTION DIAGRAMS, PHOTOMETRIC DATA, DIFFUSERS, LOUVERS, BALLAST TYPE AND QUANTITIES, LAMP TYPE AND QUANTITIES. 3. PROVIDE SAMPLES OF NFPA 70E COMPLIANT ARC FLASH HAZARD LABELING FOR ELECTRICAL EQUIPMENT. 4. MAXIMUM OF TWO REVIEWS OF COMPLETE SUBMITTAL PACKAGE. ARRANGE FOR ADDITIONAL REVIEWS AND/OR EARLY REVIEW OF LONG-LEAD ITEMS; BEAR COSTS OF THESE ADDITIONAL REVIEWS AT ENGINEER'S HOURLY RATES. INCOMPLETE SUBMITTAL PACKAGES/SUBMITTALS WILL BE RETURNED TO CONTRACTOR WITHOUT REVIEW. C. RECORD DRAWINGS: SHOW CHANGES AND DEVIATIONS FROM THE DRAWINGS. INCLUDE WRITTEN ADDENDUM AND CHANGE ORDER ITEMS. MAKE CHANGES TO DRAWINGS IN ELECTRONIC FORMAT. OBTAIN ELECTRONIC COPY FROM ARCHITECT, USE THE SAME VERSION OF AUTOCAD TO PREPARE RECORD DRAWINGS AS WAS USED BY THE ARCHITECT. PROVIDE ELECTRONIC COPY AND HARD COPY TO ENGINEER FOR REVIEW. 1.4 QUALITY ASSURANCE A. CONFORM TO THE LATEST ADOPTED VERSION OF THE CALIFORNIA ELECTRIC CODE (CEC), WITH LOCAL AMENDMENTS. B. FURNISH PRODUCTS LISTED BY UNDERWRITERS LABORATORIES INC. (UL) OR OTHER TESTING FIRM ACCEPTABLE TO AHJ. C. USE MANUFACTURER'S PUBLISHED TESTING AND ADJUSTING PROCEDURES TO ADJUST SENSORS' TIME DELAY, DAYLIGHT SENSITIVITY, AND PASSIVE INFRARED SENSITIVITY TO SATISFACTION OF THE OWNER. D. REGULATORY REQUIREMENTS: 1. PROVIDE LUMINAIRES ACCEPTABLE TO CODE AUTHORITY FOR APPLICATION AND LOCATION AS INDICATED. 2. COMPLY WITH APPLICABLE ANSI STANDARDS. 3. COMPLY WITH APPLICABLE NEMA STANDARDS. 4. PROVIDE LUMINAIRES AND LAMPHOLDERS THAT COMPLY WITH UL STANDARDS AND HAVE BEEN LISTED AND LABELED FOR LOCATION AND USE INDICATED BY A TESTING AGENCY ACCEPTABLE BY THE AHJ (E.G. UL, ETL, AND THE LIKE). 5. COMPLY WITH CEC AS APPLICABLE TO INSTALLATION AND CONSTRUCTION OF LUMINAIRES. 6. COMPLY WITH FALLOUT AND RETENTION REQUIREMENTS OF CBC FOR DIFFUSERS, BAFFLES, AND LOUVERS. 7. PROVIDE SIMILAR LAMPS AND BALLASTS FROM COMMON MANUFACTURER (E.G. ALL FLUORESCENT LAMPS FROM OSRAM/SYLVANIA, AND ALL MR LAMPS FROM USHIO) UNLESS INDICATED OTHERWISE IN THE LUMINAIRE SCHEDULE. 1.5 SEQUENCING AND SCHEDULING A. FOR THE PROPER EXECUTION OF THE WORK, COOPERATE WITH OTHER CRAFTS AND CONTRACTS AS NEEDED. B. TO AVOID INSTALLATION CONFLICTS, THOROUGHLY EXAMINE THE COMPLETE SET OF CONTRACT DOCUMENTS. RESOLVE CONFLICTS PRIOR TO INSTALLATION. C. PRIOR TO INSTALLATION OF FEEDERS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS, EXAMINE THE MANUFACTURER'S SHOP DRAWINGS, WIRING DIAGRAMS, PRODUCT DATA, AND INSTALLATION INSTRUCTIONS. VERIFY THAT THE ELECTRICAL CHARACTERISTICS DETAILED IN THE CONTRACT DOCUMENTS ARE CONSISTENT WITH THE ELECTRICAL CHARACTERISTICS OF THE ACTUAL EQUIPMENT BEING INSTALLED. 1.6 WARRANTY A. GUARANTEE ELECTRICAL WORK AGAINST FAULTY MATERIAL OR WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL COMPLETION BY THE OWNER. B. BALLAST MANUFACTURER'S WARRANTY: NOT LESS THAN 5 YEARS FOR ELECTRONIC TYPE BALLASTS, BASED ON DATE OF SUBSTANTIAL COMPLETION. INCLUDE NORMAL COST OF LABOR FOR REPLACEMENT OF BALLAST. C. LINEAR T8 AND T5 LAMP AND BALLAST COMBINATION WARRANTY: PROVIDE BALLAST AND LAMP COMBINATIONS WHICH WILL RESULT IN WRITTEN FACTORY WARRANTY COVERING LAMPS FOR 3 YEARS AND BALLASTS FOR 5 YEARS, BASED ON DATE OF SUBSTANTIAL COMPLETION. D. LAMP WARRANTY: 30 DAYS FOR INCANDESCENT, 12 MONTHS FOR COMPACT FLUORESCENT, 36 MONTHS FOR FLUORESCENT AND 12 MONTHS FOR HID LAMPS. E. LED WARRANTY: LED SYSTEMS AND COMPLETE LUMINAIRES MUST HAVE MANUFACTURER'S WARRANTY OF 3 YEARS FROM DATE OF SUBSTANTIAL COMPLETION, INCLUDING DRIVERS. PART 2 PRODUCTS 2.1 MATERIALS A. BASE CONTRACT UPON FURNISHING MATERIALS AS SPECIFIED. MATERIALS, EQUIPMENT, AND FIXTURES USED FOR CONSTRUCTION ARE TO BE NEW, LATEST PRODUCTS AS LISTED IN MANUFACTURER'S PRINTED CATALOG DATA AND ARE TO BE UL APPROVED OR HAVE ADEQUATE APPROVAL OR BE ACCEPTABLE BY STATE, COUNTY, AND CITY AUTHORITIES. EQUIPMENT/FIXTURE SUPPLIER IS RESPONSIBLE FOR OBTAINING STATE, COUNTY, AND CITY ACCEPTANCE ON EQUIPMENT/FIXTURE NOT UL APPROVED OR NOT LISTED FOR INSTALLATION. B. INCLUDE SPECIAL FEATURES, FINISHES, ACCESSORIES, AND OTHER REQUIREMENTS AS DESCRIBED IN THE CONTRACT DOCUMENTS REGARDLESS OF THE ITEM'S LISTED CATALOG NUMBER. C. PROVIDE INCIDENTALS NOT SPECIFICALLY MENTIONED HEREIN OR NOTED ON DRAWINGS, BUT NEEDED TO COMPLETE THE SYSTEM OR SYSTEMS, IN A SAFE AND SATISFACTORY WORKING CONDITION. D. FIRESTOPPING FOAM SEALANT: FOAM SEALANT FOR USE AROUND CONDUIT PENETRATIONS TO PREVENT PASSAGE OF SMOKE, FIRE, TOXIC GAS OR WATER. MAINTAIN SEAL BEFORE, DURING AND AFTER FIRE. IN AND AROUND CONDUIT FOR THERMAL BREAK AT PENETRATION OF BARRIER BETWEEN HEATED AND UNHEATED SPACES. HILTI, 3M, CHASE TECHNOLOGY CORPORATION CTC PR-855, FIRE FOAM, THOMAS & BETTS, OR APPROVED EQUIVALENT. 2.2 RACEWAYS A. RIGID METAL CONDUIT (RMC): HOT-DIP GALVANIZED AFTER THREAD CUTTING. MANUFACTURED IN CONFORMANCE WITH UL 6, ANSI C80.1. UNIFORM FINISH COAT WITH CHROMATE FOR ADDED PROTECTION. MANUFACTURERS: ALLIED TUBE & CONDUIT, BECK MANUFACTURING WL, PICOMA, OR APPROVED EQUIVALENT. B. ELECTRICAL METALLIC TUBING (EMT): STEEL GALVANIZED TUBING. MANUFACTURED IN CONFORMANCE WITH UL 797, ANSI C80.3. MANUFACTURERS: ALLIED TUBE & CONDUIT, BECK MANUFACTURING WL, PICOMA, OR APPROVED EQUIVALENT. C. FLEXIBLE METAL CONDUIT (FMC): INTERLOCKED STEEL CONSTRUCTION. MANUFACTURED IN CONFORMANCE WITH UL 1. MANUFACTURERS: AFC CABLE SYSTEMS INC., ELECTRI-FLEX COMPANY, INTERNATIONAL METAL HOSE, OR APPROVED EQUIVALENT. D. SURFACE METAL RACEWAY SYSTEMS 1. LARGE COMPARTMENT, MULTI CHANNEL SURFACE RACEWAY: a. POWER: PROVIDE 20 AMP, MULTI-OUTLET RACEWAY AS INDICATED ON DRAWINGS. WIREMOLD 5500 SERIES OR APPROVED EQUIVALENT. b. SIGNAL: BLANK COVER WITH OUTLETS AS INDICATED ON DRAWINGS. WIREMOLD 5500 SERIES OR APPROVED EQUIVALENT. 2. PROVIDE PREWIRED RECEPTACLES AS NOTED ON DRAWINGS. 3. PROVIDE ENDCAPS, CORNER JOINTS, TEES, TRANSITION FITTINGS, AND THE LIKE, FOR A COMPLETE INSTALLATION. 4. FINISH: GRAY. E. CONDUIT FITTINGS: 1. BUSHINGS: INSULATED TYPE FOR THREADED RIGID, CONDUIT OR RACEWAY CONNECTORS WITHOUT FACTORY INSTALLED PLASTIC THROAT CONDUCTOR PROTECTION. MANUFACTURERS: THOMAS & BETTS 1222 SERIES, O-Z GEDNEY B SERIES, OR APPROVED EQUIVALENT. 2. GROUND BUSHINGS: INSULATED GROUNDING TYPE FOR THREADED RIGID, CONDUIT OR RACEWAY CONNECTORS. MANUFACTURERS: O-Z GEDNEY BLG SERIES OR APPROVED EQUIVALENT. 3. RACEWAY CONNECTORS AND EMT COUPLINGS: a. STEEL CONNECTORS, COUPLINGS, AND CONDUIT BODIES WITH ZINC ELECTROPLATE. b. CONNECTOR LOCKNUTS ARE ZINC ELECTROPLATED STEEL, WITH THREADS MEETING ASTM TOLERANCES. c. CONNECTOR THROATS HAVE FACTORY INSTALLED PLASTIC INSERTS PERMANENTLY INSTALLED. FOR NORMAL CABLE OR CONDUCTOR EXITING ANGLES FROM RACEWAY, THE CABLE JACKET OR CONDUCTOR INSULATION BEARS ONLY ON PLASTIC THROAT INSERT. 4. EXPANSION/DEFLECTION FITTINGS: a. EMT: USE O_Z GEDNEY TYPE TX, OR APPROVED EQUIVALENT. b. RMC: USE O_Z GEDNEY TYPE AX, DX AND AXDX, OR APPROVED EQUIVALENT. 2.3 WIRES AND CABLES A. COPPER, 600 VOLT RATED THROUGHOUT. CONDUCTORS 14AWG TO 10AWG, SOLID. CONDUCTORS 8AWG AND LARGER, STRANDED. PHASE COLOR TO BE CONSISTENT AT FEEDER TERMINATIONS; A-B-C, TOP TO BOTTOM, LEFT TO RIGHT, FRONT TO BACK. CONDUCTORS 3AWG AND LARGER, MINIMUM INSULATION RATING OF 75C. INSULATION TYPES THWN, THHN OR XHHW. MINIMUM INSULATION RATING OF 90C FOR BRANCH CIRCUITS. MANUFACTURERS: CAROL, GENERAL CABLE, OKONITE, SOUTHWIRE, OR APPROVED EQUIVALENT. 2.4 CONNECTORS A. COPPER PADS: DRILLED AND TAPPED FOR MULTIPLE CONDUCTOR TERMINALS. B. LUGS: COMPRESSION TYPE FOR USE WITH STRANDED BRANCH CIRCUIT OR CONTROL CONDUCTORS; MECHANICAL LUGS NOT ACCEPTABLE. MANUFACTURERS: ANDERSON, ILSCO, PANDUIT, THOMAS & BETTS, 3M, OR APPROVED EQUIVALENT. C. CONDUCTOR BRANCH CIRCUITS: WIRE NUTS WITH INTEGRAL SPRING CONNECTORS FOR CONDUCTORS 18 THROUGH 8AWG. PUSH-IN TYPE CONNECTORS WHERE CONDUCTORS ARE NOT REQUIRED TO BE TWISTED TOGETHER ARE NOT ACCEPTABLE. MANUFACTURERS: 3M, IDEAL, OR APPROVED EQUIVALENT. D. FLUORESCENT LUMINAIRE DISCONNECT: POLYCARBONATE HOUSING, TIN-PLATED BRASS CONTACTS, INSULATED 18AWG, FACTORY-INSTALLED SOLID COPPER LEADS, 105C TEMPERATURE RATING, UL94-V2 FLAMMABILITY, 4A, 600V. CEC ARTICLE 410 COMPLIANT. FINGER-SAFE LINE SIDE. PUSH-AND-CLICK CONNECTOR. THOMAS & BETTS STA-KON, LITHONIA OR APPROVED EQUIVALENT. 2.5 BOXES A. LUMINAIRE OUTLET: 4-INCH OCTAGONAL BOX, 1-1/2 INCHES DEEP WITH 3/8-INCH LUMINAIRE STUD IF REQUIRED. PROVIDE RAISED COVERS ON BRACKET OUTLETS AND ON CEILING OUTLETS. MANUFACTURER: HUBBELL, THOMAS & BETTS, OR APPROVED EQUIVALENT. B. DEVICE OUTLET: INSTALLATION OF ONE OR TWO DEVICES AT COMMON LOCATION, MINIMUM 4-INCH SQUARE, MINIMUM 1-1/2 INCHES DEEP. SINGLE- OR TWO-GANG FLUSH DEVICE RAISED COVERS. MANUFACTURER: HUBBELL, THOMAS & BETTS, OR APPROVED EQUIVALENT. C. MULTIPLE DEVICES: THREE OR MORE DEVICES AT COMMON LOCATION. INSTALL ONE-PIECE GANG BOXES WITH ONE-PIECE DEVICE COVER, ONE DEVICE PER GANG. D. MASONRY BOXES: OUTLETS IN CONCRETE. MANUFACTURER: HUBBELL, THOMAS & BETTS, OR APPROVED EQUIVALENT. E. CONSTRUCTION: FOR INTERIOR LOCATIONS, PROVIDE GALVANIZED STEEL OUTLET WIRING BOXES, OF THE TYPE, SHAPE AND SIZE, INCLUDING DEPTH OF BOX, TO SUIT EACH RESPECTIVE LOCATION AND INSTALLATION; CONSTRUCTED WITH STAMPED KNOCKOUTS IN BACK AND SIDES, AND WITH THREADED HOLES WITH SCREWS FOR SECURING BOX COVERS OR WIRING DEVICES. PROVIDE OUTLET BOX ACCESSORIES FOR EACH INSTALLATION, INCLUDING MOUNTING BRACKETS, WALLBOARD HANGERS, EXTENSION RINGS, LUMINAIRE STUDS, CABLE CLAMPS AND METAL STRAPS FOR SUPPORTING OUTLET BOXES, COMPATIBLE WITH OUTLET BOXES BEING USED AND MEETING REQUIREMENTS OF INDIVIDUAL WIRING SITUATIONS. F. JUNCTION AND PULL BOXES: ANSI 49 GRAY ENAMEL PAINTED SHEET STEEL JUNCTION AND PULL BOXES, WITH SCREW-ON COVERS; OF THE TYPE SHAPE AND SIZE, TO SUIT EACH RESPECTIVE LOCATION AND INSTALLATION; WITH WELDED SEAMS AND EQUIPPED WITH STEEL NUTS, BOLTS, SCREWS AND WASHERS. INSTALL JUNCTION BOXES ABOVE ACCESSIBLE CEILINGS FOR DROPS INTO WALLS FOR RECEPTACLE OUTLETS FROM OVERHEAD. INSTALL JUNCTION BOXES AND PULL BOXES TO FACILITATE THE INSTALLATION OF CONDUCTORS AND LIMITING THE ACCUMULATED ANGULAR SUM OF BENDS BETWEEN BOXES, CABINETS AND APPLIANCES TO 270 DEGREES. MANUFACTURER: B-LINE, HOFFMAN, OR APPROVED EQUIVALENT. G. BOX EXTENSION ADAPTER: INSTALL OVER FLUSH WALL OUTLET BOXES TO PERMIT FLEXIBLE RACEWAY EXTENSION FROM FLUSH OUTLET TO FIXED OR MOVABLE EQUIPMENT. MANUFACTURER: BELL 940 SERIES, RED DOT IHE4 SERIES, OR APPROVED EQUIVALENT. 2.8 SUPPORTING DEVICES A. HANGERS, SUPPORTS, THREADED ROD AND FASTENERS: CORROSION-RESISTANT MATERIALS OF SIZE AND TYPE ADEQUATE TO CARRY THE LOADS OF EQUIPMENT AND CONDUIT, INCLUDING WEIGHT OF WIRE IN CONDUIT. MANUFACTURERS: B-LINE, KINDORF, SUPERSTRUT, UNISTRUT, OR APPROVED EQUIVALENT. B. ANCHORS: CORROSION-RESISTANT MATERIALS OF SIZE AND TYPE ADEQUATE TO CARRY THE LOADS OF EQUIPMENT AND CONDUIT, INCLUDING WEIGHT OF WIRE IN CONDUIT. MANUFACTURERS: ANCHOR IT, EPCON SYSTEM, HILTI-HIT SYSTEM, POWER FAST SYSTEM, OR APPROVED EQUIVALENT. C. CONCRETE INSERTS: CAST IN CONCRETE FOR SUPPORT FASTENERS FOR LOADS UP TO 800 LBS. MANUFACTURERS: B-LINE, KINDORF, SUPERSTRUT, UNISTRUT, OR APPROVED EQUIVALENT. D. PIPE STRAPS: TWO-HOLE GALVANIZED OR MALLEABLE IRON. E. LUMINAIRE CHAIN: CAMPBELL CHAIN 75031 OR APPROVED EQUIVALENT, 90 LB. TEST WITH STEEL HOOKS. 2.9 ELECTRICAL IDENTIFICATION A. NAMEPLATES: ENGRAVING STOCK MELAMINE OR LAMICOID PLASTIC LAMINATE, FEDERAL SPECIFICATION L-P-387, IN THE SIZE AND THICKNESSES INDICATED, ENGRAVED WITH ENGRAVER'S STANDARD LETTER STYLE, MINIMUM 1/2-INCH HIGH LETTERS, BLACK WITH WHITE CORE (LETTER COLOR), PUNCHED FOR MECHANICAL FASTENING EXCEPT WHERE ADHESIVE MOUNTING IS NECESSARY BECAUSE OF SUBSTRATE. PROVIDE 1/8-INCH THICK MATERIAL. USE SELF TAPPING STAINLESS STEEL SCREWS. MANUFACTURER: B&I NAMEPLATES, INTELLICUM, JBR ASSOCIATES, OR APPROVED EQUIVALENT. B. LABELS: ADHESIVE TAPE WITH 18 POINT BLACK LETTERS ON CLEAR BACKGROUND. USE ONLY FOR IDENTIFICATION OF INDIVIDUAL WALL SWITCHES AND RECEPTACLES, CONTROL STATIONS, AND TELECOMMUNICATION OUTLETS. INDICATE DEVICE NAME, SOURCE PANEL, AND SOURCE CIRCUITS. DO NOT PROVIDE DYMO TAPE STYLE LABELS. MANUFACTURER: KROY, BRADY, OR APPROVED EQUIVALENT. C. CONDUCTOR NUMBERS: VINYL-CLOTH SELF-ADHESIVE TYPE WIRE MARKERS. EACH CONDUCTOR AT PULLBOXES, PANELBOARDS, OUTLET BOXES, JUNCTION BOXES, AND EACH LOAD CONNECTION. BRANCH CIRCUIT OR FEEDER NUMBERS AS INDICATED ON DRAWINGS AND SOURCE PANEL. MANUFACTURER: BRADY, PANDUIT, SUMITOMO, OR APPROVED EQUIVALENT. D. BRANCH CIRCUIT SCHEDULES: PROVIDE BRANCH CIRCUIT IDENTIFICATION SCHEDULES, TYPEWRITTEN, CLEARLY FILLED OUT, TO IDENTIFY LOAD CONNECTED TO EACH CIRCUIT AND LOCATION OF LOAD. NUMBERS TO CORRESPOND TO NUMBERS ASSIGNED TO EACH CIRCUIT BREAKER POLE POSITION. E. RELAY PANEL SCHEDULE: PROVIDE TYPEWRITTEN SCHEDULE TO IDENTIFY THE INCOMING CIRCUIT, THE CONTROLLED LOAD, AND THE CONTROLLING DEVICES FOR EACH RELAY. F. CIRCUIT BREAKER IDENTIFICATION: PROVIDE PERMANENT IDENTIFICATION NUMBER IN OR ON PANELBOARD DEAD-FRONT ADJACENT TO EACH CIRCUIT BREAKER POLE POSITION. HORIZONTAL CENTERLINE OF ENGRAVED NUMBERS TO CORRESPOND WITH CENTERLINE OF CIRCUIT BREAKER POLE POSITION. 2.10 GROUNDING MATERIALS A. TELECOMMUNICATIONS GROUNDING BUSBAR (TGB): 1/4-INCH THICK BY 4-INCH HIGH BY 12-INCH LONG COPPER GROUND BAR WITH INSULATORS THAT MEET ANSI J-STD-607-A SPECIFICATIONS. UL 467 LISTED. HOLE PATTERNS IN BUSSBAR TO ACCOMMODATE TWO-HOLE LUGS. MANUFACTURERS: CHATSWORTH, ERICO, SQUARE D, PANDUIT OR APPROVED EQUIVALENT. B. GROUNDING ELECTRODE CONDUCTOR: SOFT-DRAW BARE STRANDED CONDUCTOR FOR WIRE SIZES LARGER THAN #10 AWG BARE. SOLID COPPER FOR WIRE SIZES #10 AWG AND SMALLER. C. EQUIPMENT GROUNDING CONDUCTOR: GREEN INSULATED, INSULATION TYPE TO MATCH THAT OF ASSOCIATED FEEDER OR BRANCH CIRCUIT WIRING, SIZE AS INDICATED ON DRAWINGS. 2.11 OVERCURRENT PROTECTIVE DEVICES A. FUSES: DUAL ELEMENT, TIME DELAY, CURRENT LIMITING, NONRENEWABLE TYPE, REJECTION FEATURE. UL CLASS J 1/10 TO 600 AMP, UL CLASS L, ABOVE 600 AMPS. PROVIDE FUSE PULLERS FOR COMPLETE RANGE OF FUSES. MANUFACTURERS: BUSSMANN, GOULD-SHAWMUT, LITTELFUSE, OR APPROVED EQUIVALENT. B. MOLDED CASE CIRCUIT BREAKERS: 1. ONE, TWO OR THREE-POLE BOLT ON, SINGLE HANDLE COMMON TRIP, AS INDICATED ON DRAWINGS. 2. OVERCENTER TOGGLE-TYPE MECHANISM, QUICK-MAKE, QUICK-BREAK ACTION. TRIP INDICATION IS BY HANDLE POSITION. 3. CALIBRATE FOR OPERATION IN 40C AMBIENT TEMPERATURE. 4. 15 TO 150 AMP BREAKERS: PERMANENT TRIP UNIT CONTAINING INDIVIDUAL THERMAL AND MAGNETIC TRIP ELEMENTS IN EACH POLE. 5. 151 TO 400 AMP BREAKERS: VARIABLE MAGNETIC TRIP ELEMENTS. PROVIDE PUSH-TO-TRIP BUTTON ON COVER ON BREAKER FOR MECHANICAL TRIPPING. 6. GREATER THAN 400 AMP: ELECTRONIC TRIP TYPE WITH ADJUSTMENTS FOR LONG-TIME, INSTANTANEOUS, AND SHORT-TIME FUNCTIONS. PROVIDE GROUND FAULT FUNCTION FOR BREAKERS GREATER THAN 400 AMPS. 7. PROVIDE HANDLE MECHANISMS THAT ARE LOCKABLE IN THE OPEN (OFF) POSITION. 8. MANUFACTURERS: EATON ELECTRICAL, GENERAL ELECTRIC, SIEMENS, SQUARE D, OR APPROVED EQUIVALENT. 2.12 CONTROL DEVICES A. EMERGENCY LIGHTING RELAY: 1. UL924 LISTED FOR CONNECTED LOAD OF 10 AMPS AT 277 VOLT OR 120 VOLT. 2. UL RATED N.C. CONTACTS, MINIMUM 10 AMPS RATING. INTEGRAL SURGE PROTECTION. 3. TWO SEPARATE STATUS EMERGENCY LIGHTING INDICATORS FOR TROUBLESHOOTING: a. AMBER LED INDICATES PRESENCE OF NORMAL UTILITY POWER. b. RED LED INDICATES PRESENCE OF UNSWITCHED EMERGENCY POWER. 4. MANUAL AND/OR AUTOMATIC DIAGNOSTIC TESTING FEATURE. 5. MANUFACTURER: NINE 24 BLTC-R, BODINE, WATTSTOPPER, OR APPROVED EQUIVALENT. 2.13 LUMINAIRES A. LUMINAIRES: REFER TO DESCRIPTION AND MANUFACTURERS IN LUMINAIRE SCHEDULE. B. WHERE RECESSED LUMINAIRES ARE INSTALLED IN CAVITIES INTENDED TO BE INSULATED, PROVIDE IC RATED LUMINAIRES OR OTHER CODE APPROVED INSTALLATION. C. UL LABEL LUMINAIRES INSTALLED UNDER CANOPIES, ROOF OR OPEN PORCHES, AND SIMILAR DAMP OR WET LOCATIONS, AS SUITABLE FOR DAMP OR WET LOCATIONS. D. SUSPENDED LUMINAIRES: PROVIDE MINIMUM 24-INCH ADJUSTABILITY IN AIRCRAFT CABLE LENGTH WHERE USED. E. RECESSED LUMINAIRES: FRAME COMPATIBLE WITH CEILING MATERIAL INSTALLED AT PARTICULAR LUMINAIRE LOCATION. PROVIDE PROPER FACTORY TRIM AND FRAME FOR LUMINAIRE TO FIT LOCATION AND CEILING MATERIAL. VERIFY WITH ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO SUBMITTALS. F. FINISHES: MANUFACTURER'S STANDARD FINISH (UNLESS OTHERWISE INDICATED) OVER CORROSION RESISTANT PRIMER. WHITE OR SPECULAR FINISH WITH NOT LESS THAN 85 PERCENT REFLECTANCE FOR INTERIOR LUMINAIRES. G. LIGHT TRANSMITTING COMPONENTS: PLASTIC DIFFUSERS, MOLDED OR EXTRUDED OF 100 PERCENT VIRGIN ACRYLIC. PRISMATIC ACRYLIC, EXTRUDED, FLAT DIFFUSERS, 0.125-INCH OVERALL THICKNESS, UNLESS OTHERWISE NOTED. H. FLUORESCENT LUMINAIRES: 1. PROVIDE OPEN LAMP FLUORESCENT LUMINAIRES WITHOUT DIFFUSERS OR GUARDS WITH TURRET TYPE, SPRING LOADED SOCKETS. 2. TO FACILITATE MULTILEVEL LAMP SWITCHING, WIRE LAMPS WITHIN LUMINAIRE WITH OUTERMOST LAMP AT BOTH SIDES OF LUMINAIRE ON THE SAME BALLAST, THE NEXT INWARD PAIR ON ANOTHER BALLAST AND SO ON TO INNERMOST LAMP (OR PAIR OF LAMPS). 2.14 BALLASTS A. BALLASTS, GENERAL: 1. PROVIDE BALLASTS UL RATED FOR SPECIFIED LAMPS,. 2. THERMAL PROTECTION: INTERNAL UL CLASS `P' WITH AUTOMATIC RESET. 3. SOUND RATINGS: CLASS 'A'. WHERE NOT AVAILABLE AS STANDARD PRODUCT FROM ANY SPECIFIED MANUFACTURER, PROVIDE QUIETEST RATING AVAILABLE. 4. TOTAL HARMONIC DISTORTION: NOT TO EXCEED 20 PERCENT OF THE INPUT CURRENT UNLESS OTHERWISE INDICATED. 5. INPUT VOLTAGE: PROVIDE UNIVERSAL VOLTAGE BALLAST MATCHING BRANCH CIRCUIT SUPPLY VOLTAGE. 6. PROVIDE QUANTITY OF BALLASTS TO PROVIDE SWITCHING AS INDICATED ON DRAWINGS. PROVIDE FACTORY PRINTED WIRING DIAGRAM ON BALLAST HOUSING. 7. COMPLY WITH FCC RULES AND REGULATIONS PART 18, CLASS A CONCERNING GENERATION OF BOTH ELECTROMAGNETIC INTERFERENCE AND RADIO FREQUENCY INTERFERENCE. B. BALLASTS FOR LINEAR FLUORESCENT LAMPS: 1. POWER FACTOR: MINIMUM 97 PERCENT. 2. DO NOT PROVIDE MAGNETIC FLUORESCENT BALLASTS. 3. LINEAR T8 BALLASTS: ANTI-STRIATION CIRCUITRY, AND UL TYPE CC RATED FOR ARC PROTECTION. COMPLIANT WITH NEMA/CEE HIGH PERFORMANCE T8 LIGHTING SYSTEM SPECIFICATIONS AND LISTED WITH NEMA PREMIUM ELECTRONIC BALLAST PROGRAM. 4. NON-DIMMING ELECTRONIC: a. TANDEM WIRING BETWEEN LUMINAIRES MAY BE USED TO MINIMIZE THE NUMBER OF BALLASTS WHILE ACCOMPLISHING THE SWITCHING REQUIREMENTS SHOWN ON DRAWINGS. PROVIDE LABEL IN LAMP COMPARTMENT OF LUMINAIRE TO IDENTIFY THE FUNCTION OF BALLAST. LABEL SHALL NOT BE VISIBLE FROM ROOM. b. PROVIDE BALLASTS THAT MEET REQUIREMENTS OF UL 935, ANSI C82.11 AND BEAR THE APPROPRIATE UL LABEL. PROVIDE BALLASTS THAT WITHSTAND INPUT POWER LINE TRANSIENTS AS DEFINED IN ANSI C62.41, CATEGORY-A AND IEEE 587. c. PROVIDE SERIES WIRED PROGRAMMED START BALLAST UNLESS NOTED ON DRAWINGS. d. HIGH FREQUENCY OPERATION: NOT LESS THAN 42KHZ. e. INTEGRAL END OF LAMP LIFE DETECTION AND SHUTDOWN CIRCUIT WITH AUTOMATIC RESET. f. LAMP CREST FACTOR: MAXIMUM 1.7 FOR PROGRAMMED RAPID START BALLASTS AND MAXIMUM 1.85 OR LESS FOR INSTANT START BALLASTS. g. AVERAGE BALLAST FACTOR (BF): MINIMUM 88 PERCENT OR AS INDICATED IN THE LUMINAIRE SCHEDULE. h. PROVIDE 0 DEGREE FAHRENHEIT MINIMUM STARTING TEMPERATURE BALLASTS FOR LUMINAIRES INSTALLED WHERE EXPOSED TO ANTICIPATED AMBIENT TEMPERATURE LESS THAN 55 DEGREES FAHRENHEIT. i. MANUFACTURERS: PHILIPS, UNIVERSAL LIGHTING TECHNOLOGIES, OSRAM/SYLVANIA, OR APPROVED EQUIVALENT. 5. DIMMING ELECTRONIC: a. MEET REQUIREMENTS OF NON-DIMMING ELECTRONIC BALLASTS. b. DO NOT USE TANDEM WIRING BETWEEN LUMINAIRES. c. BALLAST STARTS LAMP AT ANY PRESET LIGHT OUTPUT SETTING AND PROVIDE CONTINUOUS, SQUARE LAW DIMMING FROM 100 PERCENT TO SPECIFIED LOW-END OUTPUT. d. MANUFACTURERS: LUTRON, PHILIPS, OSRAM SYLVANIA, OR APPROVED EQUIVALENT. 2.15 LAMPS A. PROVIDE LAMPS FOR LUMINAIRES. PROVIDE LAMP CATALOGED FOR SPECIFIED LUMINAIRE TYPE. B. MANUFACTURERS: OSRAM/SYLVANIA, GENERAL ELECTRIC, PHILIPS, VENTURE, USHIO (MR ONLY), OR APPROVED EQUIVALENT UNLESS SPECIFIC MANUFACTURER IS INDICATED IN THE LUMINAIRE SCHEDULE. C. INCANDESCENT: NOT ALLOWED UNLESS NOTED IN LUMINAIRE SCHEDULE. D. FLUORESCENT: 1. PROVIDE 4100K FLUORESCENT LAMPS UNLESS NOTED IN LUMINAIRE SCHEDULE. 2. LINEAR FLUORESCENT: a. T-8: BI-PIN BASE, TRI-PHOSPHOR COATED. INITIAL 3100 LUMEN OUTPUT. CRI EQUAL TO OR EXCEEDING 85. 36000 HOURS RATED ON 3 HOUR SWITCHING CYCLE AND 42000 HOURS RATED ON 12 HOUR SWITCHING CYCLES WHEN USED WITH PROGRAMMED START BALLAST. COMPATIBLE WITH DIMMING BALLASTS. LENGTH AND WATTAGE AS INDICATED IN THE LUMINAIRE SCHEDULE. E. LED (LIGHT EMITTING DIODE): 1. LED MANUFACTURER WILL INCLUDE, BUT NOT BE LIMITED TO, LIGHT SOURCE, LUMINAIRE, POWER SUPPLY AND CONTROL INTERFACE WITH ADDED COMPONENTS AS NEEDED FOR COMPLETE AND FUNCTIONING SYSTEM. 2. COMPLY WITH ANSI CHROMATICITY STANDARD FOR CLASSIFICATIONS OF COLOR TEMPERATURE. SEE LUMINAIRE SCHEDULE FOR SPECIFIED LED LAMP COLOR AND COLOR TEMPERATURE. UL OR ETL LISTED AND LABELED. 3. LUMINAIRE TESTING PER IESNA LM-79 AND LM-80 PROCEDURES. 4. LAMP LIFE FOR WHITE LEDS: 50,000 PLUS HOURS WITH LAMP FAILURE OCCURRING WHEN LED PRODUCES 70 PERCENT OF INITIAL RATED LUMENS. 5. LAMP LIFE FOR COLOR LEDS: 30,000 PLUS HOURS WITH LAMP FAILURE OCCURRING WHEN LED PRODUCES 50 PERCENT OF ITS INITIAL RATED LUMENS. 6. PROVIDE SHOP DRAWINGS, WITH LED SYSTEMS BASED ON LUMEN OUTPUT AT 70 PERCENT LUMEN DEPRECIATION FOR WHITE LEDS AND 50 PERCENT LUMEN DEPRECIATION FOR COLOR LEDS. INITIAL LUMENS FOR ALL COLORS OF LEDS MUST BE LISTED INDIVIDUALLY. 7. LED DRIVERS: REVERSE POLARITY PROTECTION, OPEN CIRCUIT PROTECTION, REQUIRE NO MINIMUM LOAD. MINIMUM 80% EFFICIENCY. CLASS A NOISE RATING. 8. DIMMING: LED SYSTEM CAPABLE OF FULL AND CONTINUOUS DIMMING. 9. LED LIGHT SOURCE MANUFACTURERS: NICHIA, CREE, OSRAM/SYLVANIA, GE LUMINATION OR APPROVED EQUIVALENT. REG I ELECTRICAL SPECIFICATIONS RN O F CA L I F O Revisions No. Description Date Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 ELECTRICAL SPECIFICATIONS (continued) . ER ST J E 19203 EXP. 6-30-16 E A TE LE C T R I CA L IA REG I NEER NO GI EN F ESS I ON PRO AL V I D MA A I D ED ST SECTION 269000 - BUILDING LIGHTING ACCEPTANCE TESTING AND DOCUMENTATION PART 1 GENERAL 1.1 SCOPE OF WORK A. THIS SECTION DESCRIBES THE ACCEPTANCE TESTING AND DOCUMENTATION OF THE LIGHTING SYSTEM(S) AND OUTLINES THE DUTIES AND RESPONSIBILITIES OF THE CONTRACTING TEAM FOR ACCEPTANCE TESTING. B. SUPPLY THE ACCEPTANCE REQUIREMENTS TO PRODUCTS, EQUIPMENT AND SYSTEMS PROVIDED UNDER THIS DIVISION, WHERE INDICATED ON PLANS, AND WHERE REQUIRED BY CALIFORNIA TITLE 24 REQUIREMENTS. C. ENGAGE THE SERVICES OF A FIRM SPECIALIZING IN COMMISSIONING OF LIGHTING SYSTEMS OR SHALL SUBMIT CONTRACTOR QUALIFICATIONS FOR REVIEW BY ARCHITECT WHERE TESTING AND DOCUMENTATION IS TO BE PERFORMED BY CONTRACTOR. 1.2 THE COMMISSIONING TEAM A. FORM THE COMMISSIONING TEAM OF: 1. ELECTRICAL CONTRACTOR'S REPRESENTATIVE 2. LIGHTING CONTROLS MANUFACTURER'S REPRESENTATIVE 3. INSPECTOR OF RECORD 4. OWNER'S STAFF REPRESENTATIVE PART 2 PRODUCTS 2.1 DUTIES OF THE TEAM A. THE DUTIES OF THE TEAM ARE AS OUTLINED IN THE TITLE 24 REQUIREMENTS AND SUMMARIZED BELOW: 1. PLAN, ORGANIZE AND IMPLEMENT THE ACCEPTANCE TESTING PROCESS AND WITHIN 1 MONTH OF THE AWARD OF THE CONTRACT, SUBMIT THE NAMES AND ADDRESSES OF THE TESTING TEAM MEMBER(S). 2. THE ACCEPTANCE TESTING TEAM SHALL SUBMIT A COMPLETE DESCRIPTION OF THE TESTING PROCEDURES AND SYSTEMS TO BE TESTED TO THE ARCHITECT FOR REVIEW. 3. THE ACCEPTANCE TESTING TEAM SHALL COORDINATE TESTS OF SYSTEMS AND EQUIPMENT AND ASSEMBLE DOCUMENTATION RELATED TO TESTS. SUBMIT DOCUMENTATION RELATIVE TO TESTS AND PROPOSED PROCEDURES TO DESIGN ENGINEER FOR REVIEW PRIOR TO SUBMITTING DOCUMENTATION TO AUTHORITY HAVING JURISDICTION (AHJ). TEAM RESPONSIBLE FOR PERFORMING DATA ANALYSIS, CALCULATION OF PERFORMANCE INDICES AND CROSSCHECKING OF RESULTS WITH THE REQUIREMENTS OF TITLE 24 AND THE CONTRACT DOCUMENTS. THE INSTALLING CONTRACTOR OR AGENT RESPONSIBLE FOR TESTING AND DOCUMENTATION SHALL RECORD THEIR STATE OF CALIFORNIA CONTRACTOR'S LICENSE NUMBER OR THEIR STATE OF CALIFORNIA PROFESSIONAL REGISTRATION LICENSE NUMBER ON EACH CERTIFICATE OF ACCEPTANCE FOR SUBMITTAL. 4. RESPONSIBLE FOR SUBMITTING CERTIFICATE OF ACCEPTANCE INCLUDING PAPER AND ELECTRONIC COPIES OF MEASUREMENTS AND MONITORING RESULTS AND SUPPORTING DOCUMENTATION TO THE AHJ. WHERE AHJ QUESTIONS RESULTS OR REQUIRES ADDITIONAL TESTING, COMPLETE ADDITIONAL TESTING AND PROVIDE REQUIRED DOCUMENTATION AT NO ADDITIONAL COST TO THE OWNER. 2.2 TIME SCHEDULE A. DETERMINE THE TIME PERIOD OF THE COMMISSIONING OF THE SYSTEMS BY THE GENERAL CONTRACTOR AND ACCEPTANCE TESTING TEAM. IT IS IMPORTANT TO NOTE THAT AHJ WILL NOT RELEASE A FINAL CERTIFICATE OF OCCUPANCY UNTIL A CERTIFICATE OF ACCEPTANCE IS SUBMITTED THAT DEMONSTRATES THAT THE SPECIFIED SYSTEMS AND EQUIPMENT HAVE BEEN SHOWN TO BE PERFORMING IN ACCORDANCE WITH THE TITLE 24 STANDARDS. 2.3 ACCEPTANCE TESTING - PHASE I - DOCUMENTATION A. TEAM SHALL ASSEMBLE DOCUMENTATION SHOWING LIGHTING FIXTURE LOCATIONS, LIGHTING CONTROL DEVICE LOCATIONS, CONTROL SEQUENCES AND NOTES. B. PER TITLE 24 REQUIREMENTS, TEAM SHALL PROVIDE RECORD DRAWINGS TO BUILDING OWNER WITHIN 90 DAYS OF RECEIVING A FINAL OCCUPANCY PERMIT (REFER TO OTHER SPECIFICATION SECTIONS FOR REQUIREMENTS ON RECORD DRAWINGS.) C. PER TITLE 24 REQUIREMENTS, TEAM SHALL PROVIDE OPERATING AND MAINTENANCE MANUALS TO THE BUILDING OWNER (REFER TO OTHER SPECIFICATION SECTIONS FOR REQUIREMENTS ON OPERATION AND MAINTENANCE MANUALS.) 2.4 ACCEPTANCE TESTING - PHASE II - INSPECTION AND TESTING A. TEAM SHALL REVIEW THE INSTALLATION, PERFORM ACCEPTANCE TESTING AND DOCUMENT RESULTS FOR THE FOLLOWING SYSTEMS: 1. OCCUPANCY SENSORS 2. MANUAL DAYLIGHT CONTROLS 3. AUTOMATIC DAYLIGHT CONTROLS B. REVIEW OF INSTALLATION SHALL CONFIRM LIGHTING FIXTURES AND LIGHTING CONTROLS ARE PROPERLY LOCATED, IDENTIFIED, CALIBRATED, AND SET POINTS AND SCHEDULES PROGRAMMED PER CONTRACT DOCUMENT REQUIREMENTS. 2.5 ACCEPTANCE TESTING - PHASE III - CERTIFICATION A. TEAM SHALL DOCUMENT OPERATING AND MAINTENANCE INFORMATION, COMPLETE INSTALLATION CERTIFICATE, AND INDICATE TEST RESULTS ON THE CERTIFICATE OF ACCEPTANCE, AND SUBMIT THE CERTIFICATE TO THE AHJ PRIOR TO RECEIVING FINAL OCCUPANCY PERMIT. TEAM SHALL SUBMIT FORMS LTG-1-A THROUGH LTG-3-A AS REQUIRED BY TITLE 24 REQUIREMENTS. PART 3 EXECUTION 3.1 ACCEPTANCE TESTS AND DOCUMENTATION A. REFER TO CALIFORNIA TITLE 24, NON-RESIDENTIAL MANUAL FOR SPECIFIC TESTING PROCEDURES AND DOCUMENTATION REQUIREMENTS. Architecture Interiors Planning 3.6 FIELD QUALITY CONTROL A. TESTS: CONDUCT TESTS OF EQUIPMENT AND SYSTEMS TO DEMONSTRATE COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THIS DIVISION. REFER TO INDIVIDUAL SPECIFICATION SECTIONS FOR REQUIRED TESTS. DOCUMENT TESTS AND INCLUDE IN CLOSEOUT DOCUMENTS. DURING SITE EVALUATIONS BY ARCHITECT, PROVIDE AN ELECTRICIAN WITH TOOLS TO REMOVE AND REPLACE TRIMS, COVERS, DEVICES, AND THE LIKE, SO THAT A PROPER EVALUATION OF THE INSTALLATION CAN BE PERFORMED. B. TEST CONDUCTOR INSULATION ON FEEDERS OF 100 AMP AND GREATER FOR CONFORMITY WITH 1000 VOLT MEGOHMMETER. USE INSULATED CABLE ENGINEERS ASSOCIATION TESTING PROCEDURES. MINIMUM INSULATION RESISTANCE ACCEPTABLE IS 1 MEGOHM FOR SYSTEMS 600 VOLTS AND BELOW. NOTIFY ARCHITECT IF INSULATION RESISTANCE IS LESS THAN 1 MEGOHM C. LIGHTING SYSTEM CONTROL TESTING AND COMMISSIONING: 1. TEST LIGHTING CONTROLS TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. PROVIDE FUNCTIONAL TESTING OF SEQUENCES OF OPERATION TO ENSURE OPERATION IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. PROVIDE COMPLETE REPORT OF TEST PROCEDURES AND RESULTS TO ENGINEER AND INSERT APPROVED COPY INTO PROJECT CLOSEOUT DOCUMENTS. 2. TESTING SHALL INCLUDE: a. DAYLIGHT AUTOMATIC CONTROLS. b. OCCUPANT SENSING AUTOMATIC CONTROLS. c. AUTOMATIC TIME AND OVERRIDE CONTROLS FOR INTERIOR LIGHTING. D. VERIFY ELECTRICAL CHARACTERISTICS OF EQUIPMENT PRIOR TO INSTALLATION OF CONDUITS AND WIRING FOR EQUIPMENT. E. COORDINATE HVAC VOLTAGE REQUIREMENTS WITH DRAWINGS AND EQUIPMENT SUBMITTALS PRIOR TO ROUGH IN. F. WIRING DEVICE TESTS: TEST WIRING DEVICES TO ENSURE ELECTRICAL CONTINUITY OF GROUNDING CONNECTIONS, AND AFTER ENERGIZING CIRCUITRY, TO DEMONSTRATE COMPLIANCE WITH REQUIREMENTS. TEST RECEPTACLES FOR LINE TO NEUTRAL, LINE TO GROUND AND NEUTRAL TO GROUND FAULTS. CORRECT DEFECTIVE WIRING. G. USE MANUFACTURER'S PUBLISHED TESTING AND ADJUSTING PROCEDURES TO ADJUST SENSORS TIME DELAY, DAYLIGHT SENSITIVITY, AND PASSIVE INFRARED SENSITIVITY TO SATISFACTION OF THE OWNER. H. FOCUS AND ADJUST FLOODLIGHTS, SPOTLIGHTS AND OTHER ADJUSTABLE LUMINAIRES, WITH ARCHITECT, AT SUCH TIME OF DAY OR NIGHT AS REQUIRED. ALIGN LUMINAIRES THAT ARE NOT STRAIGHT AND PARALLEL/PERPENDICULAR TO STRUCTURE. POSITION EXIT SIGN DIRECTIONAL ARROWS AS INDICATED. I. VERIFICATION OF CONDITIONS: VERIFY CEILING CONSTRUCTION, RECESSING DEPTH AND OTHER CONSTRUCTION DETAILS PRIOR TO RELEASE OF LUMINAIRE FOR SHIPMENT. 3.7 CLEANING A. REMOVE DIRT AND DEBRIS CAUSED BY THE EXECUTION OF THE ELECTRICAL WORK. LEAVE THE ENTIRE ELECTRICAL SYSTEM INSTALLED IN CLEAN, DUST-FREE AND PROPER WORKING ORDER. B. THOROUGHLY CLEAN EXPOSED PORTIONS OF EQUIPMENT, REMOVING TEMPORARY LABELS AND TRACES OF FOREIGN SUBSTANCES. THROUGHOUT WORK, REMOVE CONSTRUCTION DEBRIS AND SURPLUS MATERIALS ACCUMULATED DURING WORK. C. WHERE FINISH OF LUMINAIRES OR ENCLOSURES IS DAMAGED, TOUCH UP FINISH WITH MATCHING PAINT IN ACCORDANCE TO MANUFACTURER'S SPECIFICATIONS AND INSTALLATION INSTRUCTIONS. D. CLEAN PAINT SPLATTERS, DIRT, DUST, FINGERPRINTS, AND DEBRIS FROM LUMINAIRES. RN O F CA L I F O END OF ELECTRICAL SPECIFICATIONS Revisions No. Description Date Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 TRUE NORTH W 4 1 A. THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SERVICE INSTALLATION AND/OR DEMOLITION WITH PG&E.. B. PROVISIONS SHALL BE MADE TO DISCONNECT EXISTING SERVICE EQUIPMENT AND RECONNECT NEW SERVICE EQUIPMENT WITH MINIMAL POWER DISRUPTION. C. COORDINATE EXACT LOCATIONS OF ALL ARCHITECTURAL, MECHANICAL, PLUMBING, LANDSCAPING AND CIVIL EQUIPMENT WITH ARCHITECTURAL, MECHANICAL, PLUMBING, LANDSCAPING AND CIVIL DRAWINGS. D. CIRCUIT ALL DEVICES ON THIS SHEET TO PANELBOARD P2A/P2B, UNLESS OTHERWISE NOTED. E. SIZE FUSES FOR ALL FUSED SWITCHES PER SUPPLIED EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. F. CERTAIN FEEDER AND BRANCH CIRCUIT WIRE SIZES HAVE BEEN OVERSIZED TO COMPENSATE FOR VOLTAGE DROP. SPLICE WIRES TO COMPATIBLE SIZES FOR TERMINATION, ADJACENT TO EQUIPMENT CONNECT AS REQUIRED. G. CONTRACTOR SHALL SIZE ALL IN GRADE PULL BOXES PER APPLICABLE CODE OR STANDARD, OR FOR THEIR CONVENIENCE FOR PULLING WIRE, WHICHEVER IS LARGER. 1 J J (R) J P2B-72 S BUILDING NORTH E Architecture Interiors Planning GENERAL NOTES P2B-72 2 J P2B-80/82/84 2 J 2. INSTALL OWNER FURNISHED CHARGING STATION. PROVIDE PULL BOX FOR ELECTRIC VEHICLE CHARGING STATION N16 AT STALL, USING 208V, 3PH (3) #8 +(1) #10 GND INSIDE 1" CONDUIT CIRCUIT AS SHOWN. PROVIDE 50A/3P CONTACTOR WITH RELAY CONNECTION TO A TORK DIGITAL TIME SWITCH. TIME SWITCH SHALL ACTIVATE RELAY TO CLOSE CONTACTOR AND PROVIDE POWER TO THE EV CHARGING STATION. COORDINATE WITH AUTHORITY REPRESENTATIVE FOR PROGRAMMING OF TIME CLOCK SCHEDULE. 3. (E) LIGHTS TO REMAIN. 4. RELOCATE (E) IRRIGATION CONTROLLER. EXTEND CONDUIT AND WIRE TO NEW LOCATION AS REQUIRED. REFER TO ARCHITECTURAL PLAN FOR EXACT LOCATION. 5. COORDINATE WITH SITE CONTRACTOR TO LOWER (E) SITE PULL BOX TO NEW GRADE. ADJUST BOX, RING, LID, AND CONDUITS AS REQUIRED TO LOWER BOX APPROXIMATELY 6" (MOVING FROM CURB HEIGHT TO ASPHALT HEIGHT. REFER TO ARCHITECTURAL SITE WORK PLANS FOR ADDITIONAL INFORMATION. . ST PROVIDE 120V, 1PH DEDICATED CIRCUIT FOR MOTORIZED GATE. CIRCUIT AS SHOWN AND INSTALL PER MANUFACTURER INSTRUCTIONS. USING # (2) #12 +(1) #12 +(1) #12 GND INSIDE CONDUIT 3/4". J E A TE LE C T R I CA L IA REG I 1. NEER SHEET NOTES NO (E) # E 19203 EXP. 6-30-16 ST EXISTING BUILDING F ESS I ON PRO AL V I D MA A I D ED GI EN ER P2B-74/76/78 RN O F CA L I F O 3 TYP (E) (E) (E) (E) (E) Revisions No. Description Date 3/32" = 1'-0" 33 LAS COLINAS LANE Scale 3/32" = 1'-0" 2016.01.14 Date Nov.06, 2015 Job No. 15-57 A. # IN AREAS INDICATED TO BE RENOVATED, REMOVE THAT PORTION OF THE EXISTING ELECTRICAL INSTALLATION INCLUDING, BUT NOT LIMITED TO, ALL LIGHT FIXTURES, RECEPTACLES, MOTOR/EQUIPMENT CONNECTIONS, WIRING, CONDUITS AND APPURTENANCES. ALL UNUSED WIRING AND EXPOSED CONDUIT SHALL BE REMOVED BACK TO POINT OF CONCEALMENT, UNLESS OTHERWISE NOTED. B. WHERE CONDUIT TO BE REMOVED ENTERS CONCRETE (OR SIMILAR) FLOORS AND WALLS, THE CONDUIT MAY BE ABANDONED IN THE CONCRETE. REMOVE CONDUIT FAR ENOUGH INTO THE CONCRETE TO ALLOW FOR THE INSTALLATION OF NORMAL THICKNESS OF FINISH MATERIAL. C. WHEN THE WORK NECESSITATES RELOCATION OF EXISTING CONDUIT, WIRING, OR ELECTRICAL EQUIPMENT, THE CONTRACTOR SHALL PERFORM ALL WORK AND MAKE ALL NECESSARY CHANGES TO EXISTING WORK AS MAY BE REQUIRED TO LEAVE THE COMPLETED WORK IN A FINISHED AND WORKMANLIKE CONDITION TO THE ENTIRE SATISFACTION OF THE ENGINEER. D. WHERE ELECTRICAL SYSTEMS PASS THROUGH THE RENOVATED AREAS TO SERVE OTHER PORTIONS OF THE PREMISES, THEY SHALL BE SUITABLY RELOCATED AND THE SYSTEM RESTORED TO NORMAL OPERATION. WHERE DURATION OF PROPOSED OUTAGES CANNOT BE TOLERATED BY THE OWNER, PROVIDE TEMPORARY CONNECTION AS REQUIRED TO MAINTAIN SERVICE WITH THE MINIMUM DISRUPTION POSSIBLE. E. SHEET NOTES TRUE NORTH F. WHILE PERFORMING CONNECTIONS AND/OR ALTERATIONS TO EXISTING ELECTRICAL WORK, TAKE EXTREME CARE TO PROTECT ALL EXISTING EQUIPMENT FROM DIRT, DEBRIS, AND DAMAGE. ALL DAMAGE TO SUCH EQUIPMENT SHALL BE REPAIRED AND/OR EQUIPMENT REPLACED AT THE CONTRACTOR'S EXPENSE. 1. REMOVE ALL ELECTRICAL, TELECOM, DATA, AND ASSOCIATED DEVICES IN THIS AREA, UON THAT A DEVICE IS TO REMAIN. REFER TO GENERAL NOTES FOR MORE INFORMATION. G. ALL REMOVAL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE EXECUTED WITH THE LEAST POSSIBLE DISTURBANCE TO THE BUILDING. 2. (E) DEVICES IN THIS AREA TO REMAIN, UON TO BE REMOVED. 3. REMOVE (E) DATA WIRING FROM THIS DEVICE BACK TO THE (E) TELE/DATA BACKBOARD. PROVIDE NEW DATA WIRING AS SHOWN ON ELECTRICAL FLOOR PLANS. (E) WIRING MAY BE USED TO PULL NEW WIRING TO DEVICE. H. ALL EXISTING ELECTRICAL MATERIALS NOT REUSED AND NOT SALVAGED BY THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF IN A PROPER MANNER OFF OF THE PROJECT SITE. CARE SHOULD BE TAKEN TO DISPOSE OF HAZARDOUS MATERIALS PER REQUIRED GUIDELINES. I. ANY ELECTRICAL WORK, WHICH WILL INTERFERE WITH THE NORMAL USE OF THE BUILDING IN ANY MANNER, SHALL BE DONE AT SUCH TIME OR TIMES AS SHALL BE MUTUALLY AGREED UPON BETWEEN THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE. J. (E) AND (D) DEVICE LOCATIONS AND CIRCUITS ARE BASED ON PRELIMINARY FIELD OBSERVATIONS AND ARE SHOWN FOR REFERENCE ONLY. NOT ALL DEVICES TO REMAIN OR BE REMOVED MAY BE SHOWN. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING AND VERIFY ALL REQUIRED DEMOLITION, RELOCATION, AND PROTECT-IN-PLACE WORK AS MAY BE REQUIRED. 4. RELOCATE (E) WATER HEATER. REFER TO FLOOR PLANS FOR ADDITIONAL INFORMATION. 5. (E) FLOOR MOUNTING STUDS FOR FLOOR MOUNTED 4-POST DATA RACK SHALL BE REUSED TO ANCHOR NEW DATA RACK. REFER TO FLOOR PLANS FOR MORE INFORMATION. 6. REMOVE EXISTING ROOF MOUNTED EXHAUST FAN. RETAIN EXISTING CONDUIT AND WIRE FOR REUSE. PROVIDE NEW CONDUIT AND WIRE TO MATCH EXISTING TO EXTEND CIRCUIT TO NEW FAN LOCATION. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION. W S BUILDING NORTH E Architecture Interiors Planning GENERAL DEMOLITION NOTES WHERE REMOVAL WORK IS PERFORMED, THE CONTRACTOR SHALL REPAIR ALL BUILDING SURFACES DAMAGED BY SUCH WORK. PROVIDE FINISHES TO MATCH EXISTING ADJACENT SURFACES. (E) MSB DIST (E) MSB METER/MAIN (E) DIST PNL DP1 (E) PNL P1A/P1B (E) 2 (E) (E) (E) (E) (E) PNL L1 TS P1B-55 (E) (E) PNL OSL T (E) 150KVA XFMR ON ROOF OF ELEC RM (E) P1A-26/28/30 (E) (E) TELEPHONE MPOE (E) 2 2 (E) (E) (E) (E) 2 2 (D) (D) (D) (D) P1B-69 P1B-71 (E) P1B-61 4 (D) (D) (D) 5 (D) 2 (E) (E) UP (E) P1B-47 (E) (D) P1A-29 P1A-29 3 P1B-47 P1B-56 (E) (E) (D) 2 (E) P1A-27 P1A-33 (D) 1 P1A-29 (D) P1A-35 (D) (D) P1A-27 P1A-31 (D) P1A-29 (D) (D) P1A-33 P1A-27 (D) (D) P1A-35 (D) P1B-53 P1A-31 (D) (D) (E) P1B-53 (E) P1B-53 P1B-53 (E) P1B-53 J J (E) J IA REG I (E) 2 2 J P2B-45 (E) 3 J (E) (D) (E) 2 (E) J (E) (E) P2B-43 (E) (D) (D) (D) (E) 3 2 2 (D) 3 (D) 2 (E) J 1 (E) (E) (E) (E) J (E) (E) (D) (D) (D) 3 (D) (D) (D) (D) (E) (E) P1B-45 P1A-29 P1B-47 (D) P1B-43 (E) (E) (E) (E) (E) P1A-29 RN O F CA L I F O (E) (D) (D) L (E) (E) 2 2 C T R I CA (E) J (E) P1A-25 (E) (E) (E) LE 1 (D) 2 (D) P1A-31 (D) J J P1B-51 (D) 3 3 3 (E) J (E) (E) J (E) J P2B-53 P2B-53 3 (E) (D) (E) 2 J (E) 2 (E) (E) P1B-47 J (E) (E) TE (E) 3 J (E) (E) (E) A (E) (E) J (E) (E) (E) P2B-47 (D) P2B-49 (E) P2B-49 (ON ROOF) 6 (E) (E) 3 (D) DN P2B-45 (E) (E) (D) 2 P1A-25 P1A-35 (D) J (E) P1A-14 P1A-33 (D) J 2 (D) (E) (E) (E) (E) P2B-45 (E) J (E) P1A-31 (D) 3 (D) P2B-55/57 (D) J 3 (E) (E) 2 3 (E) (E) (E) (E) (E) (E) 2 P1B-47 (E) DN 2 (E) (E) (D) (E) J (E) (E) P2B-59/61 (E) (E) 2 (E) P1B-73 (D) (E) P1B-73 (E) P1B-47 (D) (E) 2 3 (D) (E) E 3 3 . ST P1B-73 2 (E) UP (E) P1B-69 (E) (E) P1B-69 (E) (R) 1 P1B-69 (E) (E) (E) (ON ROOF) E 19203 EXP. 6-30-16 ST (E) P2A-46 P1B-75 (E) (D) P2A-44 (E) P1B-73 P1B-73 (D) (E) (E) (E) (E) (D) (D) P1B-75 P1B-73 P1B-75 (D) (E) (E) (D) (E) P2B-67/69 (E) P2B-63/65 (D) (E) P1B-73 P1B-73 1 2 2 (E) (E) 3 3 (E) (E) (E) PNL P2A/P2B 6 J NEER P1B-69 (E) TELE/DATA BACKBOARD (E) NO (E) SECURITY EQUIP F ESS I ON PRO AL V I D MA A I D ED GI EN ER (E) J J J (E) 1 3 Revisions 3 J J P1B-53 J J (E) J (E) J 3 No. Description (E) (E) (E) WP (E) Date WP 3 1/8" = 1'-0" 1/8" = 1'-0" Scale 1/8" = 1'-0" 2016.01.14 Date Nov.06, 2015 Job No. 15-57 A. IN AREAS INDICATED TO BE RENOVATED, REMOVE THAT PORTION OF THE EXISTING ELECTRICAL INSTALLATION INCLUDING, BUT NOT LIMITED TO, ALL LIGHT FIXTURES, RECEPTACLES, MOTOR/EQUIPMENT CONNECTIONS, WIRING, CONDUITS AND APPURTENANCES. ALL UNUSED WIRING AND EXPOSED CONDUIT SHALL BE REMOVED BACK TO POINT OF CONCEALMENT, UNLESS OTHERWISE NOTED. F. G. B. WHERE CONDUIT TO BE REMOVED ENTERS CONCRETE (OR SIMILAR) FLOORS AND WALLS, THE CONDUIT MAY BE ABANDONED IN THE CONCRETE. REMOVE CONDUIT FAR ENOUGH INTO THE CONCRETE TO ALLOW FOR THE INSTALLATION OF NORMAL THICKNESS OF FINISH MATERIAL. C. WHEN THE WORK NECESSITATES RELOCATION OF EXISTING CONDUIT, WIRING, OR ELECTRICAL EQUIPMENT, THE CONTRACTOR SHALL PERFORM ALL WORK AND MAKE ALL NECESSARY CHANGES TO EXISTING WORK AS MAY BE REQUIRED TO LEAVE THE COMPLETED WORK IN A FINISHED AND WORKMANLIKE CONDITION TO THE ENTIRE SATISFACTION OF THE ENGINEER. D. WHERE ELECTRICAL SYSTEMS PASS THROUGH THE RENOVATED AREAS TO SERVE OTHER PORTIONS OF THE PREMISES, THEY SHALL BE SUITABLY RELOCATED AND THE SYSTEM RESTORED TO NORMAL OPERATION. WHERE DURATION OF PROPOSED OUTAGES CANNOT BE TOLERATED BY THE OWNER, PROVIDE TEMPORARY CONNECTION AS REQUIRED TO MAINTAIN SERVICE WITH THE MINIMUM DISRUPTION POSSIBLE. E. SHEET NOTES # H. I. J. WHILE PERFORMING CONNECTIONS AND/OR ALTERATIONS TO EXISTING ELECTRICAL WORK, TAKE EXTREME CARE TO PROTECT ALL EXISTING EQUIPMENT FROM DIRT, DEBRIS, AND DAMAGE. ALL DAMAGE TO SUCH EQUIPMENT SHALL BE REPAIRED AND/OR EQUIPMENT REPLACED AT THE CONTRACTOR'S EXPENSE. ALL REMOVAL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE EXECUTED WITH THE LEAST POSSIBLE DISTURBANCE TO THE BUILDING. ALL EXISTING ELECTRICAL MATERIALS NOT REUSED AND NOT SALVAGED BY THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF IN A PROPER MANNER OFF OF THE PROJECT SITE. CARE SHOULD BE TAKEN TO DISPOSE OF HAZARDOUS MATERIALS PER REQUIRED GUIDELINES. ANY ELECTRICAL WORK, WHICH WILL INTERFERE WITH THE NORMAL USE OF THE BUILDING IN ANY MANNER, SHALL BE DONE AT SUCH TIME OR TIMES AS SHALL BE MUTUALLY AGREED UPON BETWEEN THE CONTRACTOR AND THE OWNER'S REPRESENTATIVE. (E) AND (D) DEVICE LOCATIONS AND CIRCUITS ARE BASED ON PRELIMINARY FIELD OBSERVATIONS AND ARE SHOWN FOR REFERENCE ONLY. NOT ALL DEVICES TO REMAIN OR BE REMOVED MAY BE SHOWN. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING AND VERIFY ALL REQUIRED DEMOLITION, RELOCATION, AND PROTECT-IN-PLACE WORK AS MAY BE REQUIRED. 1. LIGHT FIXTURES SHOWN (D) SHALL BE REMOVED CAREFULLY TO ALLOW CONDUITS/WIRES TO BE REUSED TO THE EXTENT POSSIBLE. 2. (E) DEVICES IN THIS AREA TO REMAIN. 3. REMOVE (E) SCONCE. RETAIN WIRING AND BACK BOX FOR NEW SCONCE INSTALLATION. 4. REMOVE (E) FIXTURES AND ASSOCIATED UNISTRUT MOUNTING SYSTEM. 5. UTILIZE (E) J-BOXES, CONDUIT, AND WIRE IN THIS SPACE FOR CONNECTION OF NEW FIXTURES. 6. NOT USED 7. REMOVE HALOGEN MR-16 LAMP FROM FIXTURE AND REPLACE WITH LED MR-16 OF EQUIVALENT LIGHT OUTPUT. PROVIDE PHILIPS LED 10W (50W INCANDESCENT EQUIVALENT) WITH 3000K CCT, 650 LUMEN OUTPUT, AND 82 CRI, MODEL # 432 401 OR APPROVED EQUAL. PROVIDE QUANTITY OF LAMPS NECESSARY TO REPLACE ALL (E) MR-16 LAMPS. WHERE REMOVAL WORK IS PERFORMED, THE CONTRACTOR SHALL REPAIR ALL BUILDING SURFACES DAMAGED BY SUCH WORK. PROVIDE FINISHES TO MATCH EXISTING ADJACENT SURFACES. 1 TRUE NORTH 8. REMOVE (E) LIGHTING AND CONTROLS IN THIS SPACE, UON TO REMAIN. 9. RELOCATE (E) 2x2 FIXTURES TO NEW CEILING GRID RECONFIGURATION. TYPICAL (9) FIXTURES. SEE NEW RCP FOR LOCATIONS. W S BUILDING NORTH 10. REMOVE EXISTING WALL PACK. 11. RELOCATE (E) LIGHT FIXTURE. MAINTAIN EXISTING CIRCUITING AND CONTROLS FOR RECONFIGURATION. EXTEND CONDUIT AND WIRING AS REQUIRED TO RESTORE TO A FULLY FUNCTIONAL STATE. E 12. RELOCATE EXISTING LIGHT SWITCHES. SEE LIGHTING PLAN FOR NEW LOCATION. Architecture Interiors Planning GENERAL DEMOLITION NOTES 10 TYP. (D) (E) 2 (E) (E) (E) (E) (E) (E) (E) (D) (E) (E) (E) (E) (E) (E) (E) (E) 2 (E) (E) (E) (E) (E) (E) (D) (D) (D) (D) (D) (E) (E) (R) (E) (E) (D) (D) (D) (D) (D) 2 (E) (E) (R) 2 (E) (E) (E) (E) (D) (D) (D) (E) (E) (D) (E) (E) (D) (D) (D) 1 TYP (D) (D) (D) (D) (D) (E) (E) (E) (E) (R) (R) (R) (D) (D) (D) (D) (E) (E) (D) (E) (E) (E) (E) 7 (E) (E) 7 (E) (E) J (E) (E) TYP OF 7 (E) (E) (E) 7 (E) (E) (E) (E) (E) (E) (E) (E) (E) 2 (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (D) (E) (D) 1 (D) 4 (E) (D) (E) (E) (E) (D) (D) (E) (D) (E) 2 7 (E) (E) (E) 7 (E) (E) 2 7 9 TYP. (E) (E) (E) (E) (D) (R) (R) (R) (D) (D) (E) (E) (E) (E) (E) 7 (E) (E) (E) (R) (E) (E) (R) (R) (R) (R) (E) (R) (D) (E) (D) (D) (R) (R) Revisions (E) No. Description (R) (E) (E) (D) (E) (R) (R) (E) (E) 8 (E) (E) (E) TYP OF 7 (E) 2 (E) (E) (E) 12 TYP (R) J (E) (E) 2 (E) (E) (E) (E) 2 (E) (E) (R) (E) RN O F CA L I F O (E) (E) (E) (D) (D) (E) (E) (E) (D) 3 5 L (E) (E) 7 (E) (E) 2 (E) (E) (E) (E) 2 (E) (E) (E) (E) (E) (E) (E) (E) C T R I CA (E) (E) (E) (E) (E) (E) (E) (E) (D) (R) (E) (E) 7 (D) (E) 2 2 (E) (E) LE (E) (E) (E) (E) (E) (E) (E) (E) 12 TYP (E) (E) (E) (E) (E) (E) (E) TE 2 2 (E) (E) (E) (D) (E) 3 (E) (E) (E) (D) (D) (D) (D) X1 (D) 2 (R) (E) (D) (E) (E) (D) 12 TYP (R) (R) (R) (E) (E) 11 (E) (E) 1 (E) (E) (R) (E) (D) (E) (D) (E) (E) (E) (E) 1 (D) (E) (E) (E) (E) (E) (E) (E) (E) 8 2 (E) (E) (E) (E) (E) (D) (E) (E) (E) (E) (E) 7 2 (E) (D) (D) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 7 (E) (E) (E) (E) (D) (E) (E) (E) 7 (E) X1(D) (E) (E) (E) (E) (E) (E) (E) (R) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (D) 11 (D) (D) (R) (D) (D) (R) (D) (E) (D) (E) (E) 2 (D) 2 11 (D) 8 (E) . ST E ST (D) (D) 2 (D) J REG I 3 A 2 NEER 1 (E) (E) (D) E 19203 EXP. 6-30-16 (E) (E) NO (E) GI EN (E) F ESS I ON PRO AL V I D MA A I D ED IA (E) ER 2 Date (E) (E) 11 (E) 1/8" = 1'-0" 1/8" = 1'-0" Scale 1/8" = 1'-0" 2016.01.14 Date Nov.06, 2015 Job No. 15-57 A. B. # SEE ARCHITECTURAL DOCUMENTS FOR EXACT PLACEMENT OF ALL LIGHT FIXTURES, EXPOSED CONTROL DEVICES AND LIGHT SWITCHES. VERIFY CEILING TYPE WITH ARCHITECTURAL DOCUMENTS AND COORDINATE TRIMS. PROVIDE ALL REQUIRED FIXTURE MOUNTING HARDWARE. COORDINATE FIXTURE TYPES WITH MOUNTING SURFACE PRIOR TO ORDERING. TRUE NORTH F. MOUNT WALL MOUNTED OCCUPANCY SENSORS AT 8'-0" ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED. 1. (E) FIXTURES AND CONTROLS IN THIS AREA TO REMAIN. G. CIRCUIT ALL LIGHT FIXTURES ON THIS SHEET TO PANELBOARD L1, UNLESS OTHERWISE NOTED. 2. INSTALL FIXTURE IN SAME LOCATION AS REMOVED FIXTURE. RECONNECT TO (E) J-BOX AND CIRCUITRY. H. PENDANT FIXTURES SHALL BE FREE TO SWING A MINIMUM OF 45 DEGREES FROM THE VERTICAL IN ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, OTHERWISE PROVIDE SEISMIC RESTRAINT. SHEET NOTES SEE DRAWING E-11 FOR LIGHT FIXTURE MOUNTING DETAILS. 3. INSTALL NEW DOWN LIGHTS. EXTEND CONDUIT AND WIRING FROM PREVIOUS TRACK LOCATION TO NEW DOWNLIGHT LOCATIONS IN THIS AREA. 7. CONNECT NEW FIXTURE TO CIRCUIT FEEDING (E) PENDANT FIXTURES TO OPEN OFFICE EXTEND (E) CONDUIT AND WIRE AS REQUIRED. 8. RELOCATE (E) PENDANT TO THIS LOCATION. EXTEND (E) CONDUIT AND WIRE AS REQUIRED. W S BUILDING NORTH 9. RELOCATED SWITCH BANK. 10. PROVIDE NEW SWITCH TO CONTROL (E) LIGHTING IN THE AREA. MODIFY CURRENTLY AS REQUIRED. C. RUN ALL INTERIOR CONDUIT IN FINISHED INTERIOR AREAS CONCEALED UNLESS OTHERWISE NOTED. 4. PROVIDE NEW 0-10V DIMMING BALLAST FOR RELOCATED FIXTURE. D. PROVIDE U.L. LISTED FIRE STOP ENCLOSURES FOR ALL RECESSED FIXTURES IN FIRE RATED CEILINGS. 5. MOUNT FIXTURE UNDER CABINET. INTERCEPT (E) ROOM LIGHTING CIRCUIT AND CONNECT TO (E) CIRCUIT. E. PROVIDE SINGLE PLATE WALL COVER FOR MULTIPLE SWITCHES. SEE DRAWINGS FOR NUMBER OF SWITCHES IN SPECIFIC LOCATIONS. 6. CONNECT NEW OR RELOCATED LIGHTING IN THIS ROOM TO (E) CIRCUITRY. PROVIDE NEW CONDUIT, AND WIRE AS REQUIRED EXTEND TO NEW FIXTURES. E 11. COORDINATE LOCATION OF S3 LIGHT WITH BOARD ROOM TABLE LOCATION BELOW. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO ROUGH IN AND INSTALL, TYPICAL ALL S3 FIXTURES. Architecture Interiors Planning GENERAL NOTES W2 2 TYP. W2 U 6 R1 D D1 S S5 S5 S2 S5 a 11 TYP. a S3 e S3 S5 Dd d a S3 a e c S3 e U S2 S2 S3 c S2 c c c S2 c c S2 c S2 c c S4 c c c S4 S4 b c U IA 1 D1 S4 3 D1 b c Db Dc 3 c Db P2 P2 6 c b P2 b b (R) S6 D DRC R1 a P b D (R) a 6 P P D b DRC (R) D 1 Revisions (R) (R) P DRC D D D 6 1 b R1 6 (R) (R) DRC D R1 DRC 6 b D D (R) R1 DRC R1 (R) (R) b D Da R1 U (R) DRC 1 6 S6 3 3 Db 6 D1 9 TYP. c DRC DRC (R) (R) (R) (R) 1 S4 S2 S2 D1 S4 S2 c c S2 3 W1 Da S2 D1 2 S2 c S2 S2 c 1 b S2 S2 U 3 3 c S3 S2 P D1 1 D1 e c 1 S2 eU c S3 S2 (R) (R) c e S2 1 Dd De S4 S3 1 1 (R) (R) (R) (R) 1 b c S2 RN O F CA L I F O 1 1 e 6 2 8 1 D S2 L W1 1 d Da Db Dc C T R I CA U D1 D1 1 W1 1 S1 9 R1 D1 LE (R) 1 DRC R1 6 S 1 1 R1 . ST D1 R1 1 S1 a 1 D J REG I a 1 S1 (R) D1 D W2 S1 6 (R) 1 6 NEER P1 NO D1 1 6 TE 1 DRC DRC P1 E A S1 S1 S1 S1 S1 S1 1 P1 TYP. 2 6 E 19203 EXP. 6-30-16 ST 5 F ESS I ON PRO AL V I D MA A I D ED GI EN ER 1 P 6 6 No. Description P 4 4 Date TYP. 8 1/8" = 1'-0" 1/8" = 1'-0" Scale 1/8" = 1'-0" 2016.01.14 Date Nov.06, 2015 Job No. 15-57 A. B. C. COORDINATE EXACT LOCATIONS OF ALL ARCHITECTURAL, MECHANICAL AND PLUMBING EQUIPMENT WITH ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS. G. CIRCUIT ALL DEVICES ON THIS SHEET TO PANELBOARD P2A/P2B, UNLESS OTHERWISE NOTED. H. SIZE FUSES FOR ALL MECHANICAL AND PLUMBING EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. D. ALL NEW DATA WIRING AND ASSOCIATED PATCH PANELS, JACKS, AND OTHER MISCELLANEOUS APPURTENANCES SHALL BE CAT6 FROM SYSTIMAX OR APPROVED EQUAL. MC CABLE MAY BE USED IN CONCEALED AREAS OF ABOVE ACCESSIBLE CEILING. EMT AND WIRE SHALL BE USED IN ALL EXPOSED LOCATIONS AND SHALL BE PAINTED TO MATCH SURFACE BEYOND. I. J. SEE EQUIPMENT SCHEDULE ELECTRICAL REQUIREMENTS FOR CIRCUITING OF EQUIPMENT AND REFER TO RISER DIAGRAMS AND DETAILS FOR ADDITIONAL INFORMATION ON WIRING, LAYOUT AND CONNECTIONS. SEE MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. F. K. 2. PROVIDE 50A/3P WELDING RECEPTACLE. CIRCUIT AS SHOWN WITH (4) #8 + (1) #10G - 1" C. COORDINATE PLUG TYPE WITH OWNER'S EQUIPMENT. 5. 6. COORDINATE EXACT LOCATION OF ALL FLOOR BOXES, CEILING BOXES, AND NEW WALL MOUNT DEVICES WITH ARCHITECT AND AUTHORITY REPRESENTATIVE PRIOR TO ROUGH IN AND INSTALLATION. PROVIDE POWER 120V/24V TRANSFORMER AS REQUIRED TO POWER VAV/BY-PASS DAMPERS, RESTROOM PLUMBING CONTROLS, DUCT SMOKE DETECTORS, MAGNETIC DOOR HOLDERS AND FIRE SMOKE DAMPERS FOR MECHANICAL EQUIPMENT. SEE DIAGRAMS ON MECHANICAL AND PLUMBING DRAWINGS FOR CONNECTION TO MECHANICAL AND PLUMBING EQUIPMENT. PROVIDE CIRCUIT FORM NEAREST AVAILABLE PANEL, UNLESS OTHERWISE NOTED. (E) DEVICES AND CIRCUIT IN THIS AREA TO REMAIN, UON. 4. EXPOSED CONDUIT ROUTING SHOWN IS APPROXIMATE. ROUTE ALL CONDUITS PARALLEL TO BUILDING STRUCTURAL ELEMENTS. PROVIDE JUNCTION BOXES FOR LOW VOLTAGE DEVICE EVERY 180 DEGREES OF BENDS. TRUE NORTH 1. 3. ALL EXISTING FLOORBOX AND DEVICE LOCATIONS ARE SHOWN AS APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATIONS IN FIELD AND COORDINATE WITH OWNER PRIOR TO COMMENCING WORK ON SITE AND PRIOR TO FINAL SELECTION AND LAYOUT OF FURNITURE. IN FINISHED INTERIOR AREAS, RUN ALL CONDUITS CONCEALED, UNLESS OTHERWISE NOTED. PAINT ALL EXPOSED CONDUITS AND ELECTRICAL EQUIPMENT. REFER TO ARCHITECTS PAINTING SECTION FOR REQUIREMENTS. E. SHEET NOTES # 14. PROVIDE CONNECTION TO WATER COOLER. COORDINATE CONNECTION AND INSTALLATION WITH MANUFACTURER REQUIREMENTS. E 18. PROVIDE RECESSED J-BOX WITH (1) 1-1/2" C. AV TO CEILING MOUNTED PROJECTOR J-BOX. COIL A MINIMUM OF 20'-0" OF SPARE DATA CABLE AT THIS LOCATION FOR EXTENSION TO MODULAR FURNITURE SYSTEM. COORDINATE WITH FURNITURE MANUFACTURER FOR FINAL CONNECTION. PROVIDE CEILING MOUNTED J-BOXES WITH (1) 3/4" C. POWER TO PANEL, (1) 1" C. DATA TO IDF, AND (1) 1-1/2" C. AV TO WALL MOUNTED J-BOX FOR PROJECTOR. COORDINATE EXACT LOCATION WITH AV REQUIREMENTS. 19. PROJECTION SCREEN CONTROLS LOCATION. 20. SAW CUT EXISTING SLAB TO FEED NEW FLOOR BOX FOR POWER, DATA, AND FUTURE AV CONNECTIVITY. REFER TO DETAIL 2/E-11 FOR MORE INFORMATION. ROUTE (1) 1-1/2" C. AV FROM FLOOR BOX TO J-BOX LOCATION AT STORAGE ROOM WALL. PROVIDE 3/4" C. POWER FROM FLOOR BOX BACK TO PANEL BOARD. PROVIDE 1" C. DATA FROM FLOOR BOX TO IDF. 21. STUB CONDUIT UP INTO WALL. ROUTE CONDUIT CONCEALED IN FURRED OUT PORTION OF WALL. SEE ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. PROVIDE 3-PHASE CONNECTION TO MODULAR FURNITURE SYSTEM. COORDINATE WHIP AND CONNECTION REQUIREMENTS WITH MANUFACTURE. CIRCUIT AS SHOWN. SEE DETAIL 4/E-10 FOR MORE INFORMATION. 22. LOCATION FOR NEW ROOF MOUNTED EXHAUST FAN. PROVIDE NEW CONDUIT AND WIRE TO MATCH EXISTING TO EXTEND EXISTING CIRCUIT AND RESTORE CIRCUIT TO A FULLY FUNCTIONAL STATE. REUSE EXISTING CONDUIT AND WIRE TO THE EXTENT POSSIBLE. 10. PROVIDE CONNECTION TO GARBAGE DISPOSAL. PROVIDE SWITCH ABOVE COUNTER FOR CONTROL AND COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO PURCHASE AND INSTALL. 23. NEW CEILING FAN, CIRCUIT AS SHOWN WITH (3) #12 + (1) #12G - 3/4" C. PROVIDE CONTROLS AT WALL LOCATION DETERMINED BY ARCHITECT. COORDINATE EXACT LOCATION OF FAN AND CONTROLS PRIOR TO ROUGH IN AND INSTALL. 11. PROVIDE CEILING MOUNTED DATA PORT FOR WIRELESS ACCESS POINT. (E) MSB DIST (E) MSB METER/MAIN (E) DIST PNL DP1 BUILDING NORTH 17. PROVIDE 120V CONNECTION TO MOTORIZED PROJECTION SCREEN. PROVIDE SWITCH ON WALL TO CONTROL SCREEN. COORDINATE WITH ARCHITECT FOR LOCATION OF SWITCH PRIOR TO ROUGH-IN AND INSTALL. PROVIDE NEW DATA CABLING FROM NEW PATCH PANELS IN NEW IDF RACK TO THIS (E) DATA LOCATION, QUANTITY AS INDICATED. PROVIDE NEW JACKS AND FACEPLATES. 8. S 16. PROVIDE RECESSED J-BOX WITH (1) 1-1/2" C. AV TO CEILING MOUNTED LCD SCREENS J-BOX. EXTEND EXISTING CONDUIT AND WIRE TO NEW WATER HEATER LOCATION AS REQUIRED TO RESTORE TO A FULLY FUNCTIONAL STATE. PROVIDE FULL HEIGHT 4-POST RACK AT THIS LOCATION. UTILIZE (E) IN-SLAB MOUNTING HARDWARE TO SECURE RACK. SEE DETAIL 2/E-10. 27. PROVIDE 2-COMPARTMENT SURFACE MOUNTED RACEWAY, WIREMOLD SERIES 5400 OR APPROVED EQUAL, TO FEED POWER AND DATA DEVICES. ROUTE RACEWAY UNDER WINDOWS. COORDINATE EXACT PLACEMENT OF POWER AND DATA DEVICES WITH ARCHITECT AND AUTHORITY REPRESENTATIVE PRIOR TO ROUGH IN AND INSTALL. 15. PROVIDE CEILING MOUNTED J-BOXES WITH (1) 3/4" C. POWER TO PANEL, (1) 1" C. DATA TO IDF, AND (1) 1-1/2" C. AV TO WALL MOUNTED J-BOX FOR CEILING MOUNTED LCD SCREENS. PROVIDE CONDUIT DOWN COLUMN TO FEED DEVICES MOUNTED ALONG BACK PANEL OF CASEWORK. REFER TO ARCHITECTURAL DOCUMENTS FOR ADDITIONAL INFORMATION. 7. 9. W Architecture Interiors Planning GENERAL NOTES 12. SAW CUT EXISTING SLAB TO FEED NEW FLOOR BOX FOR POWER, DATA, AND FUTURE AV CONNECTIVITY. REFER TO DETAIL 2/E-11 FOR MORE INFORMATION. ROUTE (1) 1-1/2" C. AV FROM FLOOR BOX TO J-BOX LOCATION AT STORAGE ROOM WALL. PROVIDE 3/4" C. POWER FROM FLOOR BOX BACK TO PANEL BOARD. PROVIDE 1" C. DATA FROM FLOOR BOX TO IDF. 24. NEW FAN COIL UNITS, AC-1 AND AC-2. CIRCUIT AS SHOWN WITH (3) #12 + (1) #12G - 3/4" C. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION. 13. PROVIDE RECESSED J-BOX WITH (1) 1-1/2" C. AV TO FLOOR BOX. 26. PROVIDE 120V/1 CONNECTION TO NEW EXHAUST FAN, EF-3. CIRCUIT WITH (2) #12 + (1) #12G - 3/4" C TO THE SAME CIRCUIT AS EF-2. 25. NEW CONDENSING UNIT ON ROOF. CIRCUIT AS SHOWN WITH (3) #8 + (1) #10G 3/4" C. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION. 2 (E) PNL P1A/P1B (E) (E) P2B-55/57/59 (E) (E) PNL L1 REG I E 19203 EXP. 6-30-16 (E) E ST A 2 1 NEER (E) ROLL DOOR DISCONNECT NO ST (E) P1A-26/28/30 (E) (E) TELEPHONE MPOE F ESS I ON PRO AL V I D MA A I D ED J (E) PNL OSL ER T (E) 150KVA XFMR GI EN TS P1B-55 (E) TE LE C T R I CA L IA (E) . (E) RN O F CA L I F O 1 3 P2A-35 P2A-35 (E) (E) P2B-61/63/65 J (EF-2 ON ROOF) 22 WP P2B-45 (E) 4 +120" AFF WAP P1B-69 (E) TELE/DATA BACKBOARD (E) (E) (E) (E) P2A-35 P1B-69 P1B-71 (E) 1 P1B-69 1 (E) IDF 7 (E) P1B-69 (E) P2A-35 UP 1 (E) (E) 1 P1B-47 13 J (2) J J J J A-33 1 8 (2) J P1A-35 P1A-31 J (6) 5 6 23 (6) (E) P1B-53 (E) P1B-53 J J 9 (E) J 5 P1B-53 6 J (E) 5 24 J (E) 1 J WAP (E) 1 (E) 1 (E) (E) P2B-43 P2B-43 (E) (E) P2B-43 9 Revisions 5 6 (6) J (E) J 9 6 (6) P2B-55/57/59 (8) P2B-73/75/77 PANEL DP-1 9 WP P2B-45 P2B-73 (2) WAP (E) 25 (CU-1 ON ROOF) WAP 6 TYP 27 Date 6 (E) (E) No. Description P2B-79/81/83 (6) J P2B-75 9 (E) P2B-53 P2B-53 (E) (E) (2) P2B-55 WAP (2) 24 23 P2B-80/82 DN 6 (2) J (2)(E) (E) 6 J 1 J 5 J 1 P2B-79/81/83 (6) J (2) 23 (E) J (E) WAP P2B-75 P2B-67/69/71 P2B-76/78 P2B-66/68/70 P1B-51 P1B-53 1 (E) 1 (E) P1A-31 (2) 5 1 1 (E) 6 J (E) P1B-53 1 (E) 1 P2B-77 (2) 9 J J (E) (E) 5 (E) P1A-31 (2) (E) (E) (2) (E) (E) (2) (E) (E) 1 (E) (E) (E) (E) P2B-76/78 11 TYP (E) (E) (2) (E) (E) P2B-49 WP (E) P2B-45 P2B-49 (E) 1 (6) 23 (2) (E) (E) (E) (2) 6 P1B-56 (E) (E) (E) P1B-45 5 P1B-47 P1B-43 (E) (E) (E) (E) (2) (E) 1 P2B-61/63/65 P2B-76/78 (2) 15 (2) (E) P2B-77 (E) 10 (E) DRYER P2B-45 (E) P2B-45 (E) (E) (EF-1 ON ROOF) 22 P2B-64 P2B-62 (2) J (2) DN J 5 J (E) 5 (E)(2) (2) 5 5 (2) J (2) 5 (E) (E) (E) (E) J (E) WAP (2) J (E) (E) 1 5 (E) (E) WAP (E) (6) (E) P2B-62 1 J J 12 (E) WAP 9 P1B-47 P1A-35 J (E) (2) (E) P2A-33 P1B-47 (E) (2) J J P2B-74 P2A-29/31 A1S P2A-33 P1B-47 P1A-31 20 P2A-33 P2A-33 (E) 1 (2) (E) 1 P2B-62 12 J (2) (E) (E)P1B-75 J 17 19 P2A-44 (2) 14 (E) 1 (E) (2) (E) (E) P1A-35 P1A-35 (2) P1 UP P1B-47 P1A-35 (2) P1A-31 (E) (E) 18 (E) (E) (E) (E) P1B-73 WASHER 5 P2B-45 (E) 13 16 21 (E) 1 (E) (2 ) P1B-73 5 P1B-75 (E) (E) (E) (E) (2) P1B-75 (E) (E) (E) P1B-73 1 P1B-73 1 WAP P1B-69 (E) (E) (E) 1 1 (2) +120" AFF P2A-46 WAP (E) (E) P2A-35 (E) PNL P2A/P2B (E) (E) WAP 26 (E) SECURITY EQUIP (R) (2) J P2B-80/82 J P2B-76/78 (E) J (E) (E) J P2B-55 (2) P2B-55 (2) P2B-57 P2B-57 (2) P2B-57 P2B-57 (E) (2) P2B-57 J (2) J (2) J P2B-57 P2B-57 (2) (E) 5 6 P2B-57 5 (E) WP (E) WP 6 Scale 1/8" = 1'-0" 2016.01.14 Date Nov.06, 2015 Job No. 15-57 1/8" = 1'-0" 1/8" = 1'-0" 3 WIRE: 4 MLO BUS: 225A VOLTAGE: SURFACE 10,000 MOUNT: AIC: PANEL L1 480/277V PHASE: 3 WIRE: 4 MAIN: MLO BUS: 100A MOUNT: SURFACE 35,000 AIC: PHASE CKT 1 2 BKR (E) 20/1 R A MEZZ REC PHASE NOTES R (E) CUBES BY WEST ENTRANCE B R (E) 20/1 3 4 (E) 20/1 R B MEZZ REC (E) CUBES BY WEST ENTRANCE C R (E) 20/1 5 6 (E) 20/1 R C CORD DROPS (E) CUBES IN FRONT OF ELEV A R (E) 20/1 7 8 WH A (E) CUBES IN FRONT OF ELEV B R (E) 20/1 9 10 WH B (E) CUBES IN FRONT OF ELEV C R (E) 20/1 11 12 WH C (E) CUBES NEXT TO TOWER A R (E) 20/1 13 14 (E) 20/1 R A (E) FRIDGE (E) CUBES NEXT TO TOWER B R (E) 20/1 15 16 (E) 20/1 R B (E) SPARE (NOT TURNED OFF) (E) CUBES NEXT TO TOWER C R (E) 20/1 17 18 (E) 20/1 R C (E) SPARE (NOT TURNED OFF) (E) CUBES UNDER PATIO A R (E) 20/1 19 20 R A (E) CUBES UNDER PATIO B R (E) 20/1 21 22 R B (E) CUBES UNDER PATIO C R (E) 20/1 23 24 R C (E) COUNTER REC A R (E) 20/1 25 26 R A (E) MICROWAVE B R (E) 20/1 27 28 R B (E) TOASTER OVEN C R (E) 20/1 29 30 R C REC BOARD ROOM A 1200 R (E) 20/1 31 32 R A REC BOARD ROOM B 800 R (E) 20/1 33 34 R B REC BOARD ROOM FLOOR BOX (E) IRRIGATION CONTROLLER C 400 R (E) 20/1 35 36 R C A R (E) 20/1 37 38 (E) 20/1 R A (E) EQUIPMENT B R 39 40 (E) 20/1 R B (E) EQUIPMENT C R 41 42 (E) 20/1 R C (E) EQUIPMENT (E) WATER FOUNTAIN A R (E) 20/1 43 a 44 (E) 20/1 L A (E) LUNCH RM LTG 2ND FLR (E) TIME CLOCK B R (E) 20/1 45 b 46 (E) 20/1 L B (E) TRACK LTG 2ND FLR (E) GFCI RR C R (E) 20/1 47 c 48 (E) 20/1 R C (E) RR 2ND FLR (E) OFFICE REC A R (E) 20/1 49 a 50 (E) 20/1 R A (E) SPARE (NOT TURNED OFF) (E) PATIO REC GFCI B R (E) 20/1 51 52 (E) 20/1 L B (E) ENTRANCE TOWER LTG (E) CONF RM REC C R (E) 20/1 53 c 54 (E) 20/1 R C (E) SPARE (NOT TURNED OFF) (E) ELEC RM REC A R (E) 20/1 55 a 56 (E) 20/1 R A (E) COLUMN QUAD REC (E) SUMP PUMP B M (E) 20/1 57 58 (E) 20/1 L B (E) ELEC RM LTG (E) WAREHOUSE REC C R (E) 20/1 59 60 (E) 20/1 L C (E) NIGHT LIGHT (E) LOBBY REC A R (E) 20/1 61 62 (E) 20/1 R A (E) 1ST FLR RR (E) EAST WAREHOUSE WALL REC B R (E) 20/1 63 64 (E) 20/1 R B (E) SPARE (NOT TURNED OFF) (E) EAST WAREHOUSE WALL REC C R (E) 20/1 65 66 (E) 20/1 L C (E) UNDER BRIDGE LTG, CONF RM (E) ELEV CONTROL A R (E) 20/1 67 a 68 (E) 20/1 L A (E) STRIP LTG (E) SERVER RM REC B R (E) 20/1 69 b 70 (E) 20/1 L B (E) STRIP LTG (E) ELEV PIT REC AND LTG C R (E) 20/1 71 72 (E) 20/1 L C (E) TIME CLOCK - EXT POLE LTG VOLTAGE: (E) FRONT OFFICE REC A R (E) 20/1 73 74 (E) 20/1 L A (E) TIME CLOCK - EXT POLE LTG PHASE: 3 (E) FRONT OFFICE REC B R (E) 20/1 75 76 (E) 20/1 L B (E) MONUMENT SIGN WIRE: 4 (E) FA SPRINKLER C R (E) 20/1 77 c 78 (E) 20/1 L C (E) MONUMENT SIGN (E) 30A SERVER REC A R (E) 30/1 79 a 80 (E) 20/1 L A (E) EXT POLE LTG (E) 30A SERVER REC B R (E) 30/1 81 b 82 (E) 20/1 L B (E) EXT POLE LTG L (E) 20/1 83 c b a c 84 (E) 30/3 (E) 40/3 (E) 30/3 (E) 20/1 L C NOTES (E) WAREHOUSE AIR AND HEAT (E) EQUIPMENT (E) PALLET JACK CHARGER (E) EQUIPMENT b) PHASE B: 800 VA 7 AMPS SUBFED CONNECTED: 0.0 KVA 0.0 AMPS 'L' DENOTES LIGHTING LOAD e) d) 'WH' DENOTES WATER HEATER LOAD f) 2.4 KVA 6.7 PANEL IS IEM ALL (E) INFORMATION IS TAKEN FROM PANEL LABELING CONTRACTOR SHALL FIELD VERIFY ACCURACY OF CIRCUITS SCHEDULE NOTES 1 ###### VOLTAGE: PANEL P2A/P2B 208/120V PHASE: 3 WIRE: 4 LOAD (E) CLG CONF RM 1 VA 2 R A (E) EF C L (E) 20/1 5 6 (E) PORTICO LTG A L (E) 20/1 7 8 9 C (E) WALL PACKS (E) 2ND FLR OFFICE LTG A L (E) 20/1 13 14 (E) 20/1 L A (E) WAREHOUSE EGRESS LTG (E) LTG B L (E) 20/1 15 16 (E) 20/1 L B (E) LOBBY EGRESS LTG (E) WEST STAIR LTG C L (E) 20/1 17 18 (E) 20/1 L C (E) FRONT OFFICE LTG (E) 2ND FLR LTG A L (E) 20/1 19 20 M A (E) 2ND FLR HALL LTG B L (E) 20/1 21 22 M B (E) LTG C L (E) 20/1 23 24 M C (E) EMS SUPPLY POWER A L (E) 20/1 25 26 (E) 20/1 L A (E) EMERG LTG SPACE B 27 28 (E) 20/1 L B (E) FRONT OFFICE LTG SPACE C 29 30 C SPACE SPACE A 31 32 A SPACE SPACE B 33 34 B SPACE SPACE C 35 36 C SPACE SPACE A 37 38 A SPACE SPACE B 39 40 B SPACE SPACE C 41 42 C SPACE LOAD 0 AMPS CONNECTED: 0.0 KVA 0.0 AMPS PHASE B: 0 VA 0 AMPS SUBFED CONNECTED: 0.0 KVA 0.0 AMPS PHASE C: 0 VA 0 AMPS DEMAND: 0.0 KVA 0.0 c) 'WH' DENOTES WATER HEATER LOAD d) PANEL IS IEM PANEL OSL PHASE VA 4 (E) 20/1 L B (E) LTG (E) LTG C L (E) 20/1 5 6 (E) 20/1 L C (E) LTG SPACE A 7 8 A SPACE SPACE B 9 10 B SPACE SPACE SPACE A 13 14 A SPACE SPACE B 15 16 B SPACE SPACE C 17 18 C SPACE SPACE A 19 20 A SPACE SPACE B 21 22 B SPACE SPACE C 23 24 C SPACE SPACE A 25 26 A SPACE SPACE B 27 28 B SPACE SPACE C 29 30 C SPACE SPACE A 31 32 A SPACE SPACE B 33 34 B SPACE SPACE C 35 36 C SPACE SPACE A 37 38 A SPACE B 39 40 B SPACE BUS: 225A SPACE C 41 42 C SPACE LOAD NOTES R (E) 20/1 9 10 (E) 20/1 R B (E) LOAD (E) LOAD C R (E) 20/1 11 12 (E) 20/1 R C (E) LOAD (E) FLOOR REC A R (E) 20/1 13 14 (E) 20/1 R A (E) LOAD (E) PHOTO BOOTH B R (E) 20/1 15 16 (E) 20/1 R B (E) LOAD (E) PHOTO BOOTH C R (E) 20/1 17 18 (E) 20/1 R C (E) LOAD A R 19 20 (E) 20/1 R A (E) LOAD B R 21 22 (E) 20/1 R B (E) LOAD C R 23 24 (E) 20/1 R C (E) LOAD A R 25 26 (E) 20/1 R A (E) LOAD VOLTAGE: B R 27 28 (E) 20/1 R B (E) LOAD PHASE: 3 29 30 (E) 20/1 R C (E) LOAD WIRE: 4 0.0 KVA 0.0 AMPS PHASE B: 0 VA 0 AMPS SUBFED CONNECTED: 0.0 KVA 0.0 AMPS PHASE C: 0 VA 0 AMPS DEMAND: 0.0 KVA 0.0 a b) 'L' DENOTES LONG CONTINUOUS LOAD PANEL DP1 208/120V R B (E) LOAD R 20/1 35 36 (E) 20/1 R C (E) LOAD 400 R 20/1 37 38 (E) 20/1 R A (E) LOAD B 400 R 20/1 39 40 (E) 20/1 R B (E) LOAD CUBICLES - 1ST FLR (E) REC AND RR GFCI C 400 R 41 42 (E) 20/1 R C (E) LOAD A R 20/1 (E) 20/1 43 a 44 (E) 20/1 A REC (E) REC AND EAST WALL COUNTER B R (E) 20/1 45 b 46 (E) 20/1 B REC (E) DISPOSAL C R (E) 20/1 47 c 48 (E) 20/1 C REC (E) REC COUNTER A R (E) 20/1 49 a 50 (E) 20/1 A CONF REC (E) MENS RR GFCI B R (E) 20/1 51 52 (E) 20/1 B CONF REC C (E) RECS C R (E) 20/1 53 c 54 (E) 20/1 C REC A 4200 a 56 (E) 20/1 A REC B 4200 R 58 (E) 20/1 B REC 60 (E) 20/1 C REC 62 20/1 R 400 A REC KITCHEN 64 20/1 R 800 B DISPOSAL PHASE A: 66 20/1 R 400 C CUBICLES - 1ST FLR 400 R 20/1 59 A 400 R 20/1 61 2 CUBICLES - 1ST FLR B 400 R 20/1 63 2 CUBICLES - 1ST FLR C 400 R 20/1 65 2 CUBICLES - 1ST FLR A 400 R 20/1 67 a 68 20/1 R 400 A CUBICLES - 1ST FLR 2 CUBICLES - 1ST FLR B 400 R 20/1 69 b 70 20/1 R 400 B CUBICLES - 1ST FLR CUBICLES - 1ST FLR C 400 R 20/1 71 72 20/1 R 400 C EXT REC, GATE CUBICLES - 2ND FLR A 400 R 20/1 73 74 20/1 R 800 A WASHER b a CUBICLES - 2ND FLR B 400 R 20/1 75 76 CUBICLES - 2ND FLR C 400 R 20/1 77 c 78 CUBICLES - 2ND FLR A 400 R 20/1 79 a 80 CUBICLES - 2ND FLR B 400 R 20/1 81 b 82 CUBICLES - 2ND FLR C 400 R 20/1 83 c 84 20/2 15/2 20/1 M 100 B M 100 C M 150 A M 150 B C NOTES PHASE VA BKR A (E) 150/3 B C A (E) PANEL P2A/P2B (E) PANEL P1A/P1B CONDENSING UNIT - CU-1 R BUS: 600A CEILING FANS CKT 1 2 3 4 5 6 7 8 9 10 BKR 50/3 PHASE R VA 3600 RN O F CA L I FO I SURFACE 35,000 R 3600 B R 3600 C R 3600 A R 3600 B LOAD EV CHARGER C R 11 12 R 3600 C A R 13 14 R 4800 A B R 15 16 R 4800 B R 17 18 R 4800 C R 19 20 R 4800 A 21 22 R 4800 B R 23 24 R 4800 C 175 AMPS CONNECTED: PHASE B: 21,000 VA 21,000 VA 175 AMPS SUBFED CONNECTED: 0.0 KVA PHASE C: 16,800 VA 140 AMPS DEMAND: 34.4 KVA DIST PNL IS IEM WITH CUTLET HAMMER BREAKERS c) (E) 200/3 40/2 50/3 50/3 50/3 NOTES A R GENERAL NOTES a) 'R' DENOTES RECEPTACLE LOAD b) (E) 200/3 CKT B C EV CHARGER Revisions No. Description Date WELDING REC WELDING REC 58.8 KVA 163.3 AMPS 0.0 AMPS 95.6 ALL (E) INFORMATION IS TAKEN FROM PANEL LABELING CONTRACTOR SHALL FIELD VERIFY ACCURACY OF CIRCUITS SCHEDULE NOTES 1 FAN COILS - FC-1 AND FC-2 SPARE 65 AMPS CONNECTED: 20.1 KVA 55.8 AMPS PHASE B: 37 AMPS SUBFED CONNECTED: 0.0 KVA 0.0 AMPS PHASE C: 7,900 VA 66 AMPS DEMAND: 15.3 KVA GENERAL NOTES 'R' DENOTES RECEPTACLE LOAD SCHEDULE NOTES PROVIDE NEW BREAKER FOR DRYER AND CIRCUIT WITH (3) # 8 + (1) # 10GL - 1"C. PROVIDE RECEPTACLE TO MATCH OWNER EQUIPMENT 1 REMOVE (E) 30A/2P CIRCUIT BREAKER IN THIS SPACE AND PROVIDE NEW BREAKER AS SHOWN. LOAD (E) SPARE 7,750 VA 4,450 VA PHASE A: 600A MCB AIC: (E) 20/1 C MAIN: MOUNT: 34 CUBICLES - 1ST FLR L SCHEDULE NOTES 33 CUBICLES - 1ST FLR C T R I CA CONTRACTOR SHALL FIELD VERIFY ACCURACY OF CIRCUITS 20/1 2 LE ALL (E) INFORMATION IS TAKEN FROM PANEL LABELING (E) LOAD 2 E GENERAL NOTES A c E 19203 EXP. 6-30-16 E CONNECTED: R 57 FESS I ON PRO AL I D MA V A I D ED AT 0 AMPS (E) 20/1 20/1 NOTES 0 VA 32 20/1 SURFACE 35,000 PHASE A: 31 R 100A SURFACE 10,000 B R (E) LTG C (E) LOAD 400 A 12 (E) ROOF GFCI REC A L 11 A B VA C R CUBICLES - 1ST FLR 2 BKR (E) 20/1 SPACE (E) 20/1 CUBICLES - 1ST FLR 1 3 8 2 BUS: LOAD (E) 20/1 7 55 MLO PHASE L (E) 20/1 CUBICLES - 1ST FLR CKT B R A CKT (E) LTG A CUBICLES - 1ST FLR MAIN: MOUNT: L (E) STORAGE RM LTG 1000 CONTRACTOR SHALL FIELD VERIFY ACCURACY OF CIRCUITS A (E) LOAD C ALL (E) INFORMATION IS TAKEN FROM PANEL LABELING (E) LTG C REC CONF, WAREHOUSE e) BKR (E) 20/1 R R (E) 480V DOCK LIFTS 0 VA 480/277V (E) 20/1 600 (E) 20/3 PHASE A: 'M' DENOTES MOTOR LOAD 6 B (E) WALL PACKS L 5 REC KITCHEN B (E) 20/1 (E) 20/1 R L 12 R 3600 10 11 C A (E) EMERG LTG (E) 20/1 (E) OFFICE REC 50/2 A L (E) EF R L (E) 20/1 C B 3600 (E) 20/1 (E) FRONT OFFICE PENDANTS R C C L (E) 20/1 DRYER WH (E) WATER HEATER B 4 (E) 20/2 B (E) 20/1 3 (E) 60/3 WH (E) 20/3 (E) FRONT OFFICE PENDANTS (E) 20/1 2 2 (E) WAREHOUSE HIGHBAYS R 400 a 4 SPACE PHASE BKR (E) 20/1 3 B (E) LOAD 1 CKT (E) 20/1 (E) OFFICE REC (E) DISHWASHER 1 CKT R BKR (E) 20/1 VA L A MLO MOUNT: PHASE A B WH MAIN: AIC: NOTES (E) WAREHOUSE HIGHBAYS NOTES LOAD NEER 6.7 AMPS 'M' DENOTES MOTOR LOAD 2 PHASE VA NO 2.4 KVA c) 1 L BKR ST CONNECTED: GENERAL NOTES a) 'R' DENOTES RECEPTACLE LOAD CKT A NOTES (E) EXT POLE LTG DEMAND: CKT BKR (E) 20/1 AIC: 10 AMPS 3 AMPS VA SCHEDULE NOTES 1,200 VA 400 VA PHASE GENERAL NOTES a) 'L' DENOTES LONG CONTINUOUS LOAD PHASE A: PHASE C: LOAD (E) WAREHOUSE HIGHBAYS GI EN C (E) 20/2 (E) 30/3 VA LOAD A (E) FRONT CAN LTG b) CKT BKR (E) 20/1 (E) LOAD VA TE R LOAD (E) CUBES BY WEST ENTRANCE REG I S NOTES Architecture Interiors Planning PHASE: MAIN: A PANEL P1A/P1B 208/120V J. VOLTAGE: 42.5 Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 Architecture Interiors Planning (E) PG&E XFMR NEMA 3R WITH PAD (E) SWITCHBOARD 'MSB' IN ELECTRICAL ROOM M (E) (E) 600A (E) 225A (E) 100A (E) 100A (E) 100A (E) 100A (E) REMOTE LOCATION CTRL (E) PNL-OSL IN ELEC. ROOM JUNCTION BOX (E) PNL-MECH IN ELEC. ROOM (E) PNL-L1 IN ELEC. ROOM TOP FEED MODULE MAIN BREAKER NEUTRAL BUILDING SERVICE CABINETT (E) ELEVATOR IN ELEVATOR CONTROL ROOM 15 OR 20 AMP CIRCUIT BREAKERS L1 (E) T1 XFMR 150 KVA WALL OR CEILING METAL CONDUIT IN ROOF OF ELECTRICAL ROOM L2 L3 (E) . ER ST J A TE LE C T R I CA L IA REG I NEER E WALL MOUNTED NO E 19203 EXP. 6-30-16 ST GROUND BAR (E) DIST. BOARD 'DP1' F ESS I ON PRO AL V I D MA A I D ED GI EN BLACK (L1) RED (L2) BLUE (L3) GREEN (GND) GREEN/YELLOW (1S0 GND) WHITE (N1) GRAY/WHITE (N3) GRAY (N2) RN O F CA L I F O (E) 600A CONNECT EITHER TOP FEED OR BASE FEED (SHOWN) GROUND (E) 200A (E) 200A (E) 150A BOND TO CABNET BASE FEED MODULE BLACK (L1) FLEXIBLE CONDUIT RED (L2) BLUE (L3) GREEN (GND) GREEN/YELLOW (ISO GND) WHITE (N1) GRAY/WHITE (N3) GRAY (N2) WALL OR FLOOR METAL CONDUIT 1 WALL OR FLOOR JUNCTION BOX 4 (E) PNL-P1A-P2B ELEC. ROOM LEVEL 1 (E) PNL-P2A-P2B STORAGE ROOM LEVEL 2 (E) PNL IN ROOF ELECTRICAL SIGLE LINE DIAGRAM NTS FURNITURE FEED POWER WIRING & CONTROLS NTS LIGHTING LOAD (a) CHATSWORTH 90"H X 19", 48 RMU FOUR POST HEAVY DUTY, UNIVERSAL OPEN RACK LIGHTING LOAD (b) LMRC-213 DIMMING ROOM CONTROLLER LIGHTING LOAD (b) NEUTRAL WHT HOT BLK 120/277V (2) TOP AND BOTTOM GROUNDING LUGS 0-10VDC DIMMING BALLAST REQUIRED. FIBER PATCH PANELS, QUANTITY AS REQUIRED CAT 6 CABLE TO NEW DATA JACK, SEE PLANS Revisions No. Description Date (X) LMSW-105 SCENE SWITCH LMRJ SERIES PRE-TERMINATED CABLES OR CAT5E. FREE TOPOLOGY & SPLITTER ACCEPTABLE LMLS-105 ON/OFF PHOTOSENSOR FOR QUANTITY AND LOCATION. (X) DESIGNATES QUANTITY OF DATA JACKS AND CABLES REQUIRED AT A GIVEN LOCATION. 48-PORT PATCH PANELS, QUANTITY AS REQUIRED LEVITON 49252-P02 HORIZONTAL CABLE MANAGEMENT, COMBO FRONT & REAR, ONE PER PATCH PANEL, TYP. POE PATCH PANELS, QUANTITY AS REQUIRED 72" MAX. LMLS-105 ON/OFF PHOTOSENSOR (AS NEEDED) DLM OCCUPANCY SENSOR NEMA 5-20R DUAL CIRCUIT VERTICAL POWER STRIP (2) PER FLOOR RACK, TYP. LMDM-101 DIMMING SWITCHES WITH LMSW-105 SCENE SWITCH ACTIVE NETWORK EQUIPMENT, FURNISHED BY OWNER, INSTALLED BY CONTRACTOR DETAIL NOTES: FINISHED FLOOR RJ45 (TYP.) EXISTING EXPANSION ANCHOR BOLTS, 3 1/2" MIN. EMBEDMENT EACH CORNER 19" FRONT VIEW 5 DLM DIMMING DIAGRAM NTS 2 A. COORDINATE WITH OWNER FOR EXACT PLACEMENT OF NETWORK EQUIPMENT B. PROVIDE ALL FIBER OPTIC AND COPPER CONNECTORS, PUNCHDOWN BLOCKS, GROMMETS, HORIZONTAL WIRE MANAGEMENT, SHELF BRACKETS, CABLE SPLICE KITS, MOUNTING HARDWARE, ETC. NECESSARY FOR 100% FULLY FUNCTIONAL AND TESTED INSTALLATION. C. ALL EQUIPMENT, JACKS, AND WIRING SHALL BE RATED FOR USE WITH CAT6 CABLE, MINIMUM. D. MANUFACTURER FOR ALL PATCH PANELS, WIRING, AND JACKS SHALL BE SYSTIMAX OR APPROVED EQUAL. FLOOR MOUNTED IDF AND MDF RACK NOT TO SCALE Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 WOOD BLOCKING AS REQUIRED - ALL AROUND FOR ACCESSIBLE CEILINGS, STUB LEVEL AND TO WITHIN 2' OF J-HOOKS. FOR GYP BOARD CEILINGS CONDUITS SHALL BE ROUTED TO MDF/IDF OR ACCESSIBLE CEILING LOCATION WITH J-HOOKS (E) 2X WOOD JOISTS 2 X 4 BLOCKING. AT TWO SIDES MIN TO FASTEN BLOCKING TO CEILING JOISTS. WITH 2-16d NAILS OR EQUIVALENT EACH END. (TYP) ROOF STRUCTURE, OR NEXT FLOOR NYLON BUSHING, TYP. PROVIDE 1/4" EYE SCREW WITH MIN 1" THREADED LENGTH IN BOTTOM CHORD 3/4" C. MIN., (2) #12 GAGE HANGER WIRE CONNECT TO STRUCTURE ABOVE 2-GANG J- BOX WITH SINGLE GANG PLASTER RING, FACE PLATE & JACKS, TYP. CONDITION AT (E) TRUSS JOIST (2) #10 SCREWS, FOUR TOTAL 2 X 4 BLOCKING W/ SIMPSON U24 JOIST HANGAR OR EQUIVALENT EACH END LAMP HOLDER FIXTURE SUPPORT, ROUTE FIXTURE HANGER WIRE TO STRUCTURE AS REQUIRED TWO PER ASSEMBLY DETAIL NOTES: SECTION VIEW JUNCTION BOX AND/OR TRANSFORMER/BALLAST ASSEMBLY PLAN +18"AFF, UON FINISHED FLOOR 1. SEE FLOOR PLANS FOR QUANTITY AND LOCATION OF TELE/DATA/CATV OUTLET BOXES. FACEPLATE COLOR AS DIRECTED BY THE ARCHITECT CONDITION 2 - INSTALLED IN (E) TRUSS JOISTS 6 FIXTURE REFLECTOR RECESSED FIXTURE MOUNTING VERIFY VOICE JACK REQUIREMTS WITH SPECIFICATIONS, TYP. FINISHED CEILING DATA TELE 3. SCALE: NONE CAT 6 JACK, TYP. GREEN CAT 6, TYP. DOWNLIGHT FIXTURE MOUNTING 3 BLUE CAT 6, TYP. TO PUNCH DOWN BLOCK OR IDF PROVIDE (4) PORT FACEPLATE, TYP. 4. LABEL ALL FACEPLATES PER SCHOOL DISTRICT STANDARDS OR DIRECTION (NO EXCEPTIONS). TO IDF 5. PROVIDE BLANKS COVERS FOR ALL UNUSED PORTS. BLANK SCALE: NONE 2. TERMINATE AND TEST ALL TELEPHONE, DATA AND CATV JACKS BACK TO MDF/IDF AND TO ACTIVE HEADEND EQUIPMENT. WALL MOUNTED OCCUPANCY SENSOR E FOR BUILDING WALL CONSTRUCTION SEE ARCHITECTURAL DRAWINGS 96" SWITCH 1 SURFACE MOUNTED FIXTURE 90" ST FRONT VIEW NEER E 19203 EXP. 6-30-16 WOOD BUILDING STUDS CATV AND RECEPTACLE F ESS I ON PRO AL V I D MA A I D ED NO LABEL POCKETS WITH CLEAR PLASTIC COVER, TYP. GI EN 6. FOR NEW DATA PORT LOCATIONS IN EXISTING WALLS, A CUT IN BOX MAY BE USED, AND WIRING MAY BE FISHED THROUGH THE EXISTING WALL WITHOUT THE USE OF CONDUIT. LOCATIONS IN NEW WALLS SHALL UTILIZE CONDUIT AS SHOWN. A TE LE C T R I CA L IA (2) 2 X 4 SLEEPERS AT EACH SIDE OF DIAGONAL WEB MEMBERS ER 3/8" DIA MACHINE BOLTS THROUGH SLEEPERS SECTION LIGHT FIXTURE, MOUNT BOTTOM OF FIXTURE FLUSH WITH BOTTOM OF TRUSS . 3/8" DIA MACHINE BOLTS THROUGH SLEEPERS PROVIDE 1/4" EYE SCREW WITH MIN 2" PENETRATION. ST (2) 2 X 4 SLEEPERS AT EACH SIDE OF DIAGONAL WEB MEMBERS MIN 1" J CONDITION 1 - INSTALLED IN 2X FRAMING T-BAR CEILING Architecture Interiors Planning (E) 2X JOIST, SEE ADJACENT DETAIL FOR CONDITION AT (E) TRUSS JOIST SECURE TO BLOCKING WITH (4) # 10 WOOD SCREWS WITH FLAT WASHER. PENETRATE 1 1/4" INTO (N) BLOCKING OR (E) JOISTS. REG I PLASTER OR GYPSUM BOARD CEILING FINISH - REMOVE TO INSTALL BLOCKING AS REQUIRED & REPLACE J-HOOKS, 4' O.C. MIN., 12" MAX. SAG FOR LOW VOLTAGE CABLING, TYP. RN O F CA L I F O TELE/DATA/CATV OUTLET DETAIL SCALE: NONE RECEPT DATA / VOICE RECEPTACLE 48" 48" (REFER TO CBC 1136a FOR SPECIAL APPLICATION) 52" PROVIDE SIMPSON L50 CLIPS ON TOP AND BOTTOM OF BLOCKING. SECURE TO BLOCKING WITH 10 PENNY CUT NAILS FL-500P-4 C LIFT UP LID PROVIDE FLOOR BOX WITH (2) 20 AMP DUPLEX RECEPTACLES & (2) TELE/DATA FACEPLATES & JACKS. SEE POWER & SIGNAL FLOOR PLANS AND AUDIOVISUAL PLANS FOR QUANTITY AND TYPE OF JACKS REQUIRED. 15" PROVIDE BLANKS FACEPLATE FOR UNUSE OPENINGS AND BLANKS FOR UNUSED PORTS. 7 TYPICAL MOUNTING HEIGHTS DETAIL NOTES: SCALE: NONE A. ALL PART NUMBERS SHOWN ARE FSR PRODUCTS, NO EQUAL. B. SEE FLOOR PLANS FOR QUANTITY AND SIZE AND ROUTING OF CONDUITS. C. SEE SYSTEM DIAGRAMS, POWER & SIGNAL PLANS & SPECIFICATIONS, AND AUDIOVISUAL CONSULTANT'S PLANS & SPECIFICATIONS FOR QUANTITY AND LAYOUT OF RECEPTACLES, DATA, VIDEO, AUDIO, AND AUDIOVISUAL SYSTEM CONNECTORS. PROVIDE ALL FITTINGS AND MISCELLAEOUS HARDWARE FOR A NEAT, FINISHED AND PROFESSIONAL INSTALLTION. NO LOSE CABLING OR CONNECTORS PERMITTED. D. ALL OPENINGS SHALL BE CONCEALED WITH A FACEPLATE OR BLANK PORT JACK, NO EXCEPTIONS. E. ALL FLOOR BOX DOORS SHALL BE INSTALLED WITH HINGE SIDE FACING FRONT OF STAGE. PROVIDE 1/4" EYE SCREW WITH MIN 2" PENETRATION. SEE 3/- SIMILAR. 4 - #10 WOOD SCREWS WITH FLAT WASHER, 4 PER FIXTURE PENETRATE 1 1/4" INTO BLOCKING BLOCKING TO BUILDING STUDS STRUCTURE WIRE TO SUPPORT "T-BAR" CEILING GRID BY OTHERS (TYP) 4 TWO ADDITIONAL #12 GA SLACK WIRE AT OPPOSITE CORNERS OF FIXTURE W/ FOUR (4) TURNS FOR EACH #12 WIRE IN 1-1/2" DISTANCE. (BY ELECTRICAL CONTRACTOR) "T-BAR" CLIPS WALL FIXTURE MOUNTING ON WOOD STUDS LIGHT FIXTURE SCALE: NONE (12) 1" & 1-1/4" CONDUIT KNOCKOUTS GROUND TERMINAL STRUCTURE ISO VIEW LAG SCREW 3/8" DIA 2" PENETRATION ENCLOSURE TOP IS TO BE PLUMB, LEVEL AND FLUSH WITH THE FINISHED CONCRETE SURFACE. CEILING GRID SYSTEM BY OTHERS POWER FEED 8 ADDRESS ALL RECEPTACLES AND JACK PER SCHOOL DISTRICT'S ADDRESSING CONVENTION. TYPICAL. 2' X 2' GRID FIXTURE MOUNTING TEMPORARY CONSTRUCTION COVER TO BE REPLACED BY FINISH COVER PRIOR TO CARPET INSTALLATION. CARPET IS TO BE CUT TO TOUCH THE SIDES OF THE RAISED TRIM. 4" SQUARE CEILING Revisions 5" LONG ADJUSTMENT SCREWS PROVIDED IN THE PAN KIT. FL-GRD4 CONCRETE POUR PAN No. Description Date SCALE: NONE 4x6 BLOCKING WITH U46 JOIST HANGER EACH END WOOD SPACER BETWEEN STRIPPING LOCK NUTS (BY FIXTURE COMPANY) (E) 2X WOOD FRAMING (SIMILAR AT TRUSS JOIST) 1 GANG / 2 GANG POWER / DATA CROSS BAR (BY FIXTURE COMPANY) TUBULAR PENDANT (BY FIXTURE COMPANY) CONCRETE SLAB 4 GANG AV CANOPY WOOD STRIPPING CANOPY FASTENER (BY FIXTURE COMPANY) PROVIDE SIMPSON L50 CLIPS ON EACH SIDE OF BLOCKING. SECURE TO BLOCKING WITH 10 PENNY CUT NAILS. SEE 6/1, CONDITION 2 (SIM) FOR SUPPORT OF 4X6 AT TRUSS JOIST GRAVEL FILL LOCK NUT GRADE FASTENING SCREW ACOUSTIC TILE, GYPSUM BOARD OR PLASTER PROVIDE 1/4" WOOD SCREW WITH FLAT WASHER WITH MIN 2" PENETRATION. SECURE TO BLOCKING, ONE EACH CORNER GLASS GLOBE SECTION VIEW SURFACE MOUNTED FIXTURE 9 SURFACE FIXTURE MOUNTING SCALE: NONE 5 PENDANT FIXTURE MOUNTING SCALE: NONE 2 FSR FL-500-P4 CONCRETE POUR FLOOR BOX DETAIL SCALE: NONE Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 SIMSON U24 HANGER OR EQUIVALENT EACH END 1 4 Architecture Interiors Planning 2" EMBED. 121x121x16GAx121" (MIN) 1 4 EYESCREW THREADED ROD 2x4 MIN ADDED BLOCKING WHERE (E) FRAMING DOES NOT ALIGN WITH HANGER/WIRE/STRAP STRAP WIRE (CABLE SIMILAR) . ST J E ST CABLE OR WIRE AT TRUSS INTERSECTIONS 1 4" SCREW (1"MIN EMBED) P TE LE C T R I CA L RN O F CA L I F O STRAP W/ FOLD C END AT CENTERLINE OF BOTTOM CHORD P NEER E 19203 EXP. 6-30-16 A 1 4 NO F ESS I ON PRO AL V I D MA A I D ED GI EN ER SCALE: NONE REG I 1 SUPPORT FORM 2x FRAMING & SUPPLEMENTAL BLOCKING IA 2" MIN TYP 1 4 16GA x 121" MIN BENT PLATE P (MAX PERMISSABLE LOAD, P = 20#) 2 SUPPORT FROM TRUSS JOISTS SCALE: NONE (E) TRUSS JOIST 3 8 2x4 MIN 2-2x4 (EACH SIDE OF DIAG WEB MEMBERS) 3x4 MIN WITH SIMPSON U34 OR EQUIV. EACH END 3x4 MIN Revisions No. Description Date P = 100# MAX ADDED BLOCKING WHERE FRAMING IS NOT ALIGHED WITH SUPPORT LOCATION OR P > 20# 3 SUPPORT FROM TRUSS JOISTS - CON'TD SCALE: NONE Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION LUMINAIRE SCHEDULE+F2:OF2:O14 Indoor Lighting (Page 1 of 5) Project Name: Open Space Authority LAMP WATTS LAMP TYPE D1 26 LED BALLAST TYPE VOLTS DESCRIPTION MOUNTING MANUFACTURER REMARKS Climate Zone: Conditioned Floor Area : Unconditioned Floor Area : ELECTRONIC DIMMING DRIVER 120/277 RECESSED 6" DIAMETER LED DOWNLIGHT. 20 GAUGE DIE-FORMED GALVANIZED STEEL HOUSING. EXTRUDED ALUMINUM HEATSIN K. LOW IRIDESCENT ALUMINUM REFLECTOR WITH CLEAR, SEMI-SPECULAR FINISH. 0-10V DIMMING CAPABILITIES. RECESSED HE WILLIAM S 1. COORDINATE VOLTAGE WITH EXISTING LED60-PH20-835-EDD* FIXTURES BEING REMOVED. SOME FIXTURES PH OR APPROVED MAY BE 120V, WHILE OTHERS MAY BE 277V. EQUAL 2. COORDINATE CEILING MOUNTING CONDITION WITH PLANS. PROVIDE T-BAR MOUNTING OR GYP BOARD MOUNTING AS REQUIRED. General Information Building Type: X Nonresidential Relocatable Public Schools Phase of Construction: New Construction Method of Compliance: Complete Building Hotel/Motel Unconditioned Spaces Conditioned Spaces Addition X X Alteration Area Category Tailored Architecture Interiors Planning FIXTURE CODE Date Prepared: 1/4/16 LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included) P1 P2 13.8/FT 14 LED LED ELECTRONIC DIMMING DRIVER ELECTRONIC DIMMING DRIVER 120/277 120/277 LINEAR LED PENDANT. 20 GAUGE DIE-FORMED STEEL HOUSING WITH INTEGRAL JOINER SYSTEM. FLAT ENDCAPS. HIGH OUTPUT UPLIGHT, HIGH OUTPUT DOWNLIGHT. FULLY ADJUSTABLE AIRCRAFT CABLE MOUNTING. WHITE FINISH. 0-10V DIMMING CAPABILITIES. DECORATIVE 6" DIAMETER X 8" TALL LED PENDANT. EXTRUDED WHITE ACRYLIC HOUSING WITH MATTE FINISH. 0-10V DIMMING CAPABILITIES. PENDANT CABLE PENDANT CABLE FINELIGHT SERIES S16 S16LEDID-DCO-8-3E-H O-HO-3500K-SC-120/27 7-FA-FE-C1 OR APPROVED EQUAL BORDEN LIGHTING 345-LED1/14-120/277-S AL-STEM-0-10VDIM OR APPROVED EQUAL 1. COORDINATE VOLTAGE WITH EXISTING FIXTURES BEING REMOVED. SOME FIXTURES MAY BE 120V, WHILE OTHERS MAY BE 277V. 2. MOUNT BOTTOM OF FIXTURE AT +8'-0" AFF. 1. COORDINATE VOLTAGE WITH EXISTING FIXTURES BEING REMOVED. SOME FIXTURES MAY BE 120V, WHILE OTHERS MAY BE 277V. 2. MOUNT BOTTOM OF FIXTURE AT +8'-0" AFF. For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO FORM TITLE X Certificate of Compliance. All Pages required on plans for all submittals. X Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. X Indoor Lighting Power Allowance X Tailored Method Worksheets X Line Voltage Track Lighting Worksheets Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance S1 S2 6.1 33 LED LED ELECTRONIC DIMMING DRIVER ELECTRONIC DIMMING DRIVER 120 120/277 SURFACE MOUNTED UNDER CABINET 22.25" LED LIGHT WITH INTEGRAL DIMMING AND OCCUPANCY SENSOR. SILVER FINISH. SURFACE MOUNTED 5" DIAMETER LED CAN LIGHT. XICATO REMOTE PHOSPHOR LED MODULE. SPECULAR CLEAR ALZAK REFLECTOR CONE. WHITE HOUSING. WIDE BEAM DISTRIBUTION. 0-10V DIMMING CAPABILITIES. SURFACE SURFACE FINELITE EDGE SERIES UC-E-22"-S-PS-8W-OCC OR APPROVED EQUAL 1. PROVIDE QUANTITY OF POWER SUPPLIES AND CONNECTOR CABLES AS REQUIRED. 2. PROVIDE QUANTITY OF 22" SECTIONS OF UNDERCABINET LIGHT TO MATCH LENGTH SHOWN ON PLANS. KURT VERSEN 1. COORDINATE VOLTAGE WITH EXISTING L132-35-ES-WT-PC OR FIXTURES BEING REMOVED. SOME FIXTURES APPROVED EQUAL MAY BE 120V, WHILE OTHERS MAY BE 277V. 2. MOUNT BOTTOM OF FIXTURE FLUSH WITH BOTTOM OF STRUCTURAL TRUSSES. PROVIDE LENGTH OF STEM AS REQUIRED. Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Watts + 1. 2. 2570.1 + PORTABLE ONLY FOR OFFICES 3. Watts + 0 603.5 4. = Adjusted Installed Lighting Power (row 1 plus row 2 minus row 3) 3599.8 1966.6 603.5 Adjusted Installed Lighting Power (row 1 minus row 3) = 2996.3 STATE OF CALIFORNIA INDOOR LIGHTING SURFACE KURT VERSEN 1. COORDINATE VOLTAGE WITH EXISTING L136-35-ES-WT-PC OR FIXTURES BEING REMOVED. SOME FIXTURES APPROVED EQUAL MAY BE 120V, WHILE OTHERS MAY BE 277V. 2. MOUNT BOTTOM OF FIXTURE FLUSH WITH BOTTOM OF STRUCTURAL TRUSSES. PROVIDE LENGTH OF STEM AS REQUIRED. 3. MOUNT FIXTURES ABOVE BOARD ROOM TABLE. COORDINATE EXACT LOCATION WITH OWNER AND ARCHITECT PRIOR TO ROUGH IN AND INSTALL. CEC-NRCC-LTI-01-E (Revised 06/13) Indoor Lighting 5. 6. 3599.8 120/277 SURFACE MOUNTED LED WALL WASHER. WHITE HOUSING. CANOPY MOUNT WITH A FULLY ADJUSTABLE YOKE. 0-10V DIMMING CAPABILITY. SURFACE TIMES SQUARE WX30-9535-W-120/277CM4-010 OR APPROVED EQUAL 1. COORDINATE VOLTAGE WITH EXISTING FIXTURES BEING REMOVED. SOME FIXTURES MAY BE 120V, WHILE OTHERS MAY BE 277V. 2. MOUNT FIXTURE SUCH THAT BOTTOM OF FIXTURE EXTENDS 2" BELOW THE BOTTOM OF THE STRUCTURAL TRUSSES SO THE FIXTURE CAN BE ADJUSTED WITHOUT INTERFERENCE FROM THE TRUSSES. NO Form/Title X X 33 LED ELECTRONIC DIMMING DRIVER 120/277 RECESSED LED CAN LIGHT WALL WASHER. SPECULAR ALZAK CONE. WHITE TRIM. 0-10V DIMMING CAPABILITY. RECESSED R1 31 36 LED LED ELECTRONIC DIMMING DRIVER ELECTRONIC DIMMING DRIVER UNV UNV 2' DIAMETER SURFACE MOUNTED LENSED LED LIGHT. SPUN ALUMINUM OUTER HOUSING WITH MATTE WHITE POWDER COATED FINISH. FROSTED ACRYLIC LENS. 0-10V DIMMING CAPABILITY. RECESSED 2' X 2' LED TROFFER. MATTE WHITE REFLECTOR AND HOUSING WITH ROUNDED, FROSTED ACRYLIC LENS. 0-10V DIMMING CAPABILITIES. SURFACE RECESSED LE C T R I CA L RN O F CA L I F O multipurpose room, or a theater to be recognized for compliance. X KURT VERSEN 1. COORDINATE VOLTAGE WITH EXISTING A5250-20-35-27-FMR4- FIXTURES BEING REMOVED. SOME FIXTURES WT OR APPROVED MAY BE 120V, WHILE OTHERS MAY BE 277V. EQUAL 2. AIM FIXTURES TOWARDS NEAREST WALL. 3. PROVIDE 0-10V DIMMING BALLAST IN LIEU OF LUTRON ECOSYSTEM BALLAST. HE WILLIAMS 1. MOUNT FIXTURE IN EXISTING J-BOX RNDS-2-L25/835-FXA-DI LOCATIONS. REUSE EXISTING BACKBOX, M-UNV OR APPROVED CONDUIT, AND WIRE TO THE EXTENT POSSIBLE. EQUAL TE X X YES S6 ST A X S5 E 19203 EXP. 6-30-16 E for compliance. NEER ELECTRONIC DIMMING DRIVER F ESS I ON PRO AL V I D MA A I D ED NO LED Date Prepared: 1/4/16 GI EN 41.4 (Page 2 of 5) Project Name: Open Space Authority YES S4 CALIFORNIA ENERGY COMMISSION IA SURFACE MOUNTED 5" DIAMETER LED CAN LIGHT. XICATO REMOTE PHOSPHOR LED MODULE. SPECULAR CLEAR ALZAK REFLECTOR CONE. WHITE HOUSING. NARROW BEAM DISTRIBUTION. 0-10V DIMMING CAPABILITIES. ER 120/277 . ELECTRONIC DIMMING DRIVER ST LED J 33 REG I S3 NO Form/Title X X X HE WILLIAMS LT-22-L34/835-AF-DIMUNV OR APPROVED EQUAL STATE OF CALIFORNIA X1 6 LED ELECTRONIC DRIVER UNV UNIVERSAL MOUNT LED EXIT SIGN WITH INTEGRAL BATTERY PACK AND DUAL EMERGENCY LIGHTS. MOLDED THERMOPLASTIC HOUSING. LED MR16 LAMPS. GREEN LETTERING. 90 MINUTE RUN TIME. UNIVERSAL EMERGILITE 1. MOUNT BOTTOM OF FIXTURE AT 8'-0" AFF. W-PR-1224H-4-G-2-LJ OR APPROVED EQUAL INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION Indoor Lighting (Page 3 of 5) Project Name: Open Space Authority W1 14 LED ELECTRONIC DIMMING DRIVER UNV INTERIOR LED WALL SCONCE. SOLID ALUMINUM FINISH. WHITE ACRYLIC SHIELDING WITH MATTE FINISH. ADA COMPLIANT. WALL MOUNTED Date Prepared: 1/4/16 BORDEN LIGHTING 1. MOUNT FIXTURE IN EXISTING FIXTURE 508-LED2/7-UNV-SAL LOCATION. REUSE EXISTING BACKBOX, CONDUIT, OR APPROVED EQUAL AND WIRE TO THE EXTENT POSSIBLE. A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: W2 34 LED ELECTRONIC DIMMING DRIVER UNV EXTERIOR TRAPEZOIDAL LED WALL PACK. TYPE II, WIDE THROW OPTIC DISTRIBUTION. INTEGRAL AUTOMATIC PROFILE DIMMING. NATURAL ALUMINUM PAINT FINISH. INTEGRAL PHOTOCELL CONTROLS. WALL MOUNTED PHILIPS GARDCO 100 1. MOUNT FIXTURE IN EXISTING FIXTURE LINE LED LOCATION. REUSE EXISTING BACKBOX, CONDUIT, 101L-APD-2-35LA-NW-U AND WIRE TO THE EXTENT POSSIBLE. NIV-NP-PCB-WS OR APPROVED EQUAL A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST X The actual indoor lighting power listed on this page and on the next page includes all installed permanent and planned portable lighting systems. X When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines Revisions No. Description of this compliance form. Date shall not be traded between offices having different lighting systems. Office Portable Luminaire Schedule A Complete Luminaire Description (i.e., LED, under cabinet, furniture mounted direct/indirect) Accountabl e Watts Office Installed Portable Luminaire Watts Per Square Foot B Watts per Luminaire C D Installed portable luminaire watts in this office (B x C ) E F H G Watts per square foot (D enter zero; /E) Field Inspector Office Location I J Identify Office area in which these portable luminaires are installed ExG Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57 STATE OF CALIFORNIA STATE OF CALIFORNIA INDOOR LIGHTING INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CEC-NRCC-LTI-01-E (Revised 06/13) Indoor Lighting (Page 4 of 5) Project Name: Open Space Authority CALIFORNIA ENERGY COMMISSION Indoor Lighting Date Prepared: 1/4/16 (Page 5 of 5) Project Name: Open Space Authority Date Prepared: 1/4/16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: J. DAVID MAINO Documentation Author Signature: Company: INTEGRAL GROUP Signature Date: Address: 1084 FOXWORTHY AVE, SUITE 150 CEA/ HERS Certification Identification (if applicable): City/State/Zip: SAN JOSE, CA 95118 Phone: 408-448-6300 C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Installed Watts Luminaire Schedule A B C Location D E F Field Inspector 1 G H RESPONSIBLE PERSON'S DECLARATION STATEMENT How wattage was determined Complete Luminaire Description (i.e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballast) Primary Function area in which these luminaires are installed D1 Recessed LED downlight 26 X 13 338 General lighting for hallways P1 Linear LED pendant 55.1 X 3 165.3 Conference rm lighting P2 Decorative LED pendant 14 X 3 42 Reception table lighting S1 Undercabinet LED light 6.1 X 10 61 Task lighting S2 Surface mounted LED can light 33 X 24 792 General lighting for board room S3 Surface mounted LED can light 33 X 8 264 Board room table lighting S4 Surface mounted LED can light wallwasher 41.4 X 7 289.8 Wall lighting for board room S5 Recessed LED can light wallwasher 33 X 4 132 Wall lighting for board room S6 Surface mounted LED lensed fixture 31 X 2 62 Conference rm lighting R1 Recessed 2'x2' LED troffer ADA compliant LED wall Sconce 36 X 11 396 Office lighting 14 X 28 2570.1 Stair lighting W1 2 INSTALLED WATTS PAGE TOTAL: Pass Architecture Interiors Planning A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: Fail I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: J. DAVID MAINO Responsible Designer Signature: Company: INTEGRAL GROUP Date Signed: Address: 1084 FOXWORTHY AVE, SUITE 150 License: E19203 City/State/Zip: SAN JOSE, CA 95118 Phone: 408-448-6300 Enter sum total of all pages into STATE OF CALIFORNIA STATE OF CALIFORNIA CEC-NRCC-LTI-02-E (Revised 06/13) CEC-NRCC-LTI-02-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE (Page 2 of 5) (Page 1 of 5) Project Name: Open Space Authority Project Name: Open Space Authority Date Prepared: 1/4/16 Date Prepared: 1/4/16 . ST J E ST A with Section 130.4(b). LE C T R I CA L RN O F CA L I F O MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST X X TE IA REG I E 19203 EXP. 6-30-16 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: X NEER X NO Control Requirements NO F ESS I ON PRO AL V I D MA A I D ED GI EN YES ER Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with Section 130.4.(a). The controls required PAF Credit Calculation 2 A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.3. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). X Standards Complying With 1 Section 130.1. X Lighting Control Schedule A All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). X General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. B C Type/ Description of Lighting Control (i.e.: occupancy sensor, automatic time switch, dimmer, automatic daylight, # of Units D E F G H I J K L M N O Location in Building X X X Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. X Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Registration Number: Registration Date/Time: BOARD ROOM OCC. SENSOR, DAYLIGHT CONTROLS 1 X X X X E N/A X 1477.8 0.25 369.45 X OFFICES OCC. SENSOR, DAYLIGHT CONTROLS 3 X X X X E N/A X 144 0.25 36 X CONFERENCE ROOMS OCC. SENSOR, DAYLIGHT CONTROLS 3 X X X X E N/A X 341.3 0.25 85.325 X WORK ROOM OCC. SENSOR 1 X X X N/A E N/A N/A 61 0.25 15.25 X HALLWAY OCC. SENSOR 2 X X X N/A E N/A N/A 390 0.25 97.5 X HERS Provider: Registration Number: Registration Date/Time: HERS Provider: STATE OF CALIFORNIA STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-02-E (Revised 06/13) CEC-NRCC-LTI-03-E (Revised 06/13) CALIFORNIA ENERGY COMMISSION CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE (Page 3 of 5) Project Name: Open Space Authority (Page 1 of 4) Project Name: Open Space Authority Date Prepared: 1/4/16 Date Prepared: 1/4/16 INSTALLED WATTS PAGE TOTAL: 2570.1 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF ALL PAGES HERE: LOWED LIGHTING POWER (Chose Method) A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: J. DAVID MAINO Documentation Author Signature: Company: INTEGRAL GROUP Signature Date: Address: 1084 FOXWORTHY AVE, SUITE 150 CEA/ HERS Certification Identification (if applicable): City/State/Zip: SAN JOSE, CA 95118 Phone: 408-448-6300 X If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed building watts (a) (b) Revisions No. Description Date 3599.8 RESPONSIBLE PERSON'S DECLARATION STATEMENT B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE A B C WATTS PER (ft2) COMPLETE BLDG. AREA X Documentation Author Name: J. DAVID MAINO Responsible Designer Signature: Company: INTEGRAL GROUP Date Signed: Address: 1084 FOXWORTHY AVE, SUITE 150 License: E19203 City/State/Zip: SAN JOSE, CA 95118 Phone: 408-448-6300 D ALLOWED WATTS = Total Area: Registration Number: Registration Date/Time: Total Watts. Enter Total Watts into section A, row 1 (Above on this page) Watts HERS Provider: CORRIDOR . 450 OFFICE (< 250 SF) . 445 CONFERENCE . Registration Number: Registration Date/Time: 2704.8 HERS Provider: Scale N.T.S 2016.01.14 Date Nov.06, 2015 Job No. 15-57