Quick-Lock 1-16 inch Bondstrand® 2000M/7000M Glassfiber Reinforced Epoxy (GRE) pipe systems for marine service with external pressure requirements Taper/Taper 18-40 inch Uses and applications ● ● ● ● ● Ballast Chlorination Draining Cargo line Sanitary service & sewage ● ● ● ● ● Portable discharge line Stripping lines Tankcleaning (salt water) Fire protection mains Various other applications A complete library of Bondstrand pipe and fittings in PDS and PDMS-format is available on CD-ROM. Please contact Ameron for details. For specific fire protection requirements, an outher layer of passive fire protection is available. For pipe systems without external pressure requirements, please refer to Bondstrand 3400 product data (FP 835) or contact your Ameron representative. Approvals In 1993, IMO (International Maritime Organisation) issued a resolution (A.18/Res. 753) covering acceptance criteria for assuring ship safety. Major certifying bodies have adopted and implemented these Guidelines in their respective Rules and Regulations for the Classification of Ships. All Bondstrand pipe series used in the marine industry are designed and type-approved by the below major certifying bodies. (A complete list is available, on request) ● American Bureau of Shipping (ABS), U.S.A.; ● Bureau Veritas, France; ● Det Norske Veritas, Norway; ● Germanischer Lloyd, Germany; ● Lloyd’s Register, United Kingdom; ● Nippon Kaiji Kyokai, Japan; ● Registro Italiano Navale (RINA), Italy; ● United States Coast Guard (USCG), U.S.A.. Characteristics Maximum operating temperature: up to 121°C. Pipe diameter: 1-40 inch (25-1000 mm). Pipe system design for pressure ratings up to 16 bar. ASTM D-2992 Hydrostatic Design Basis (Procedure B - service factor 0.5); ASTM D-1599 Safety factor of 4:1. Design criteria for external pressure requirements are in accordance with IMO regulations. Bondstrand 2000M ASTM D-2310 Classification: RTRP-11FW for static hydrostatic design basis; MDA cured. ASTM D-2310 Classification: RTRP-11FX for static hydrostatic design basis; IPD cured. Complies with ASTM F-1173 Classification. Bondstrand 7000M ASTM D-2310 Classification: RTRP-11AW for static hydrostatic design basis; MDA cured. ASTM D-2310 Classification: RTRP-11AX for static hydrostatic design basis; IPD cured. Complies with ASTM F-1173 Classification. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 1 of 28. Printed in The Netherlands. Table of Contents GENERAL DATA Adhesives ...................................................................................................................27 Conversions ...............................................................................................................28 Engineering design & installation data .......................................................................28 Hydrostatic testing ......................................................................................................28 Important notice ..........................................................................................................28 Joining system and configuration .................................................................................3 Mechanical properties ..................................................................................................4 Physical properties .......................................................................................................4 Pipe series ....................................................................................................................3 Pipe length ...................................................................................................................4 Pipe dimensions and weights .......................................................................................7 Pipe performance ..................................................................................................... 5-6 Span length ..................................................................................................................9 Surge Pressure ..........................................................................................................28 Ultimate Collapse Pressures ........................................................................................8 FITTINGS DATA Adaptors ............................................................................................................... 26-27 Bell mouth ..................................................................................................................25 Couplings ...................................................................................................................22 Elbows ....................................................................................................................9-11 Expansion coupling ....................................................................................................26 Flanges ................................................................................................................. 20-22 Joint dimensions Quick-Lock® ....................................................................................8 Joint dimensions Taper/Taper .......................................................................................8 Laterals .......................................................................................................................17 Nipples .......................................................................................................................23 Reducers .............................................................................................................. 18-19 Saddles ............................................................................................................. 17 & 24 Specials ....................................................................................................................28 Tees .......................................................................................................................11-16 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 2 of 28. Printed in The Netherlands. Pipe series Pipe Filament-wound Glassfiber Reinforced Epoxy (GRE) pipe for Bondstrand adhesivebonding systems. MDA (diaminodiphenylmethane) or IPD (isophoronediamine) cured. Fittings A wide range of lined filament-wound Glassfiber Reinforced Epoxy (GRE) fittings for Bondstrand adhesive-bonding systems. For special fittings, not listed in this product guide, please contact your Ameron representative. Flanges Filament-wound Glassfiber Reinforced Epoxy (GRE) heavy-duty flanges, hubbed and stub-end flanges for Quick-Lock adhesive bonding systems. Standard flange drilling patterns as per ANSI B16.5 (150 Lb). Other flange drilling patterns, such as ANSI B16.5 (> 150 Lb), DIN, ISO and JIS are also availabe. Bondstrand® 2000M Glassfiber Reinforced Epoxy (GRE) pipe system; IPD or MDA cured. Standard 0.5 mm internal resin-rich reinforced liner. Maximum operating temperature: 121°C for MDA cured and 93°C for IPD cured. Maximum pressure rating: 16 bar. Minimum pressure: full vacuum. External Pressure Requirements: In accordance with IMO Regulations. Bondstrand® 7000M (* conductive) Glassfiber Reinforced Epoxy (GRE) pipe system; IPD or MDA cured. Maximum operating temperature: 121°C for MDA cured and 93°C for IPD cured. Maximum pressure rating: 16 bar. Minimum pressure: full vacuum. External Pressure Requirements: In accordance with IMO Regulations. * Conductive Our conductive pipe systems have been developed to prevent accumulation of potentially dangerous levels of static electrical charges. Pipe, fittings and flanges contain high strength conductive filaments. Together with a conductive adhesive this provides an electrically continuous system. Description Pipe diameter Joining system Liner **Temperature Pressure Rating * ** Joining system & configuration Bondstrand® 2000M 1-40 inch Quick-Lock 1-16 inch Taper/Taper 18-40 inch *0.5 mm 121°C 16 bar Bondstrand® 7000M 1-40 inch Quick-Lock 1-16 inch Taper/Taper 18-40 inch 121°C 16 bar Also available without liner; Above 93°C, derate the pressure rating lineairly to 50% at 121°C. Pipe 25-400 mm (1-16 inch): Quick-Lock (straight/taper) adhesive joint with integral pipe stop in bell end. End configuration: Integral Quick-Lock bell end x shaved straight spigot. 450-1000 mm (18-40 inch): Taper/Taper adhesive joint. End configuration: Integral Taper bell x shaved taper spigot Fitting 25-400 mm (1-16 inch): Quick-Lock (straight/ taper) adhesive joint with integral pipe stop in bell end. End configuration: Integral Quick-Lock bell ends. 450-1000 mm (18-40 inch): Taper/Taper adhesive joint. End configuration: Integral Taper bell ends. Flanges 25-1000 mm (1-40 inch): Quick-Lock (straight/ taper) adhesive joint with integral pipe stop in bell end. End configuration: Integral Quick-Lock bell end. Note: * Pipe nipples, saddles and flanged fittings have different end configurations. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 3 of 28. Printed in The Netherlands. Typical pipe length Nominal Length* Plant [mm] 25-40 50-125 150 200 250 300-400 450-1000 Pipe Size Asia Plant [inch] 1-1½ 2-5 6 8 10 12-16 18-40 Joining Approximate overall System Europe Quick-Lock Quick-Lock Quick-Lock Quick-Lock Quick-Lock Quick-Lock Taper/Taper [m] 5.5 6.15 6.1 6.1/11.8 6.1/11.8 6.05/11.8 11.8 [m] 3.0 5.85/9.0 5.85/9.0 5.85/9.0 5.85/11.89 5.85/11.89 11.89 Method Ameron Ameron — — — ASTM D-792 * Tolerance +/- 50 mm. Typical physical properties Pipe property Thermal conductivity pipe wall Thermal expansivity (lineair) Flow coefficient Absolute roughness Density Specific gravity Units W(m.K) 10-6 mm/mm °C Hazen-Williams 10-6 m kg/m3 - Value .33 18.0 150 5.3 1800 1.8 Typical mechanical properties Pipe property IPD cured Bi-axial Ultimate hoop stress at weeping Circumferential Hoop tensile strength Hoop tensile modulus Poisson’s ratio axial/hoop Longitudinal Axial tensile strength Axial tensile modulus Poisson’s ratio hoop/axial Axial bending strength Beam Apparent elastic modulus Hydrostatic Design Basis Static Units 21°C. 93°C. Method N/mm2 300 — ASTM D-1599 N/mm2 N/mm2 — 380 23250 0.93 — 18100 1.04 ASTM D-2290 ASTM D-2290 Ameron N/mm2 N/mm2 — — 65 10000 0.40 80 50 7800 0.45 — ASTM D-2105 ASTM D-2105 ASTM D-2105 Ameron N/mm2 9200 7000 ASTM D-2925 N/mm2 148* — ASTM D-2992 (Proc. B.) 21°C. 93°C. Method N/mm2 250 — ASTM D-1599 N/mm2 N/mm2 — 220 25200 0.65 — 0.81 ASTM D-2290 ASTM D-2290 Ameron N/mm2 N/mm2 — — 80 12500 0.40 85 65 9700 0.44 — ASTM D-2105 ASTM D-2105 ASTM D-2105 Ameron N/mm2 12500 8000 ASTM D-2925 N/mm2 124* — ASTM D-2992 (Proc. B.) Pipe property MDA cured Bi-axial Ultimate hoop stress at weeping Circumferential Hoop tensile strength Hoop tensile modulus Poisson’s ratio axial/hoop Longitudinal Axial tensile strength Axial tensile modulus Poisson’s ratio hoop/axial Axial bending strength Beam Apparent elastic modulus Hydrostatic Design Basis Static Units * At 65°C. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 4 of 28. Printed in The Netherlands. Typical pipe performance . Bondstrand 2000M (MDA cured) at 21°C. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 STIS Stifness Factor Pipe Stiffness [kN/m2] 2079.1 618.1 350.6 102.2 110.8 57.7 33.4 35.5 36.6 35.9 36.8 36.9 36.2 36.3 36.6 36.9 36.8 37.1 36.8 37.7 [lb.in] 502 502 554 554 1281 1281 1281 3092 6375 10627 13548 20308 28265 38976 67877 121531 148680 182139 256919 361759 [psi] 16187 4812 2729 796 863 449 260 276 285 280 286 287 282 283 285 288 286 289 286 294 STIS Stifness Factor Pipe Stiffness [kN/m2] 2087.4 620.6 352.0 102.6 111.3 57.9 33.5 35.6 36.8 36.1 36.9 37.1 36.3 36.5 36.6 36.9 36.8 37.1 36.8 37.7 [lb.in] 504 504 556 556 1286 1286 1286 3104 6400 10669 13602 20389 28378 39130 68147 122013 149270 182862 257939 363195 [psi] 16251 4831 2740 799 866 451 261 277 286 281 287 289 283 284 285 289 288 290 288 295 Bondstrand 2000M (IPD-cured) at 21°C. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 5 of 28. Printed in The Netherlands. Typical pipe performance Bondstrand 7000M (MDA-cured) at 21°C. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 STIS Stifness Factor Pipe Stiffness [kN/m2] 3142.4 949.6 534.7 157.3 154.4 80.6 46.7 39.4 38.2 37.2 38.0 37.2 38.0 37.2 36.7 37.1 36.9 37.3 36.9 37.9 [lb.in] 797 797 867 867 1809 1809 1809 3092 6375 10627 13548 20308 28265 38976 67877 121531 148680 182139 256919 361759 [psi] 24464 7393 4162 1225 1202 627 363 276 285 280 286 287 282 283 285 288 286 289 286 294 STIS Stifness Factor Pipe Stiffness [kN/m2] 3154.9 953.3 536.8 157.9 155.0 80.9 46.9 35.6 36.8 36.1 36.9 37.1 36.3 36.5 36.7 37.1 36.9 37.3 36.9 37.9 [lb.in] 800 800 871 871 1816 1816 1816 3104 6400 10669 13602 20389 28378 39130 68147 122013 149270 182862 257939 363195 [psi] 24561 7422 4179 1230 1207 630 365 277 286 281 287 289 283 284 286 289 288 290 288 295 Bondstrand 7000M (IPD-cured) at 21°C. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 6 of 28. Printed in The Netherlands. Typical pipe dimensions and weights Bondstrand 2000M. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 400 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Pipe Minimum Average Inside Struct. Wall Pipe Diameter Thickness [t] Weight [mm] [mm] [kg/m] 27.1 3.0 0.7 42.1 3.0 1.3 53.0 3.1 1.3 81.8 3.1 1.8 105.2 4.1 3.1 131.9 4.1 3.5 159.0 4.1 4.6 208.8 5.5 7.4 262.9 7.0 12 313.7 8.3 17 337.6 9.0 19 385.8 10.3 25 433.8 11.5 32 482.1 12.8 39 578.6 15.4 56 700.0 18.7 75 750.0 20.0 93 800.0 21.4 102 900.0 24.0 132 1000.0 26.9 165 MDA RTRP-11 FW1-2112 RTRP-11 FW1-2112 RTRP-11FW1-2112 RTRP-11FW1-2112 RTRP-11FW1-2113 RTRP-11FW1-2113 RTRP-11FW1-2113 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 RTRP-11FW1-2116 Designation per ASTM D-2966 IPD FX1-3112 FX1-3112 FX1-3112 FX1-3112 FX1-3113 FX1-3113 FX1-3113 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 FX1-3116 MDA RTRP-11AW1-2112 RTRP-11AW1-2112 RTRP-11AW1-2112 RTRP-11AW1-2112 RTRP-11AW1-2113 RTRP-11AW1-2113 RTRP-11AW1-2113 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 RTRP-11AW1-2116 Designation per ASTM D-2966 IPD AX1-3112 AX1-3112 AX1-3112 AX1-3112 AX1-3113 AX1-3113 AX1-3113 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 AX1-3116 Bondstrand 7000M. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Pipe Minimum Average Inside Struct. Wall Pipe Diameter Thickness [t] Weight [mm] [mm] [kg/m] 27.1 3.5 0.7 42.1 3.5 1.3 53.0 3.6 1.3 81.8 3.6 1.8 105.2 4.6 3.1 131.9 4.6 3.5 159.0 4.6 4.6 208.8 5.5 7.4 262.9 7.0 12 313.7 8.3 17 337.6 9.0 19 385.8 10.3 25 433.8 11.5 32 482.1 12.8 39 578.6 15.4 56 700.0 18.7 75 750.0 20.0 93 800.0 21.4 102 900.0 24.0 132 1000.0 26.9 165 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 7 of 28. Printed in The Netherlands. Ultimate collapse pressure Ultimate collapse pressure (ultimate short term external failure pressure) at 21º C. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Internal Pressure static* [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 2000M MDA 2000M IPD 7000M MDA 7000M IPD [bar] 491 160 95 29 31 16.5 9.7 10.3 10.7 10.5 10.7 10.7 10.5 10.6 10.7 10.8 10.7 10.8 10.7 11.0 [bar] 491 160 95 29 31 16.5 9.7 10.3 10.7 10.5 10.7 10.7 10.5 10.6 10.7 10.8 10.7 10.8 10.7 11.0 [bar] 714 239 141 44 43 23 13.5 10.3 10.7 10.5 10.7 10.7 10.5 10.6 10.7 10.8 10.7 10.8 10.7 11.0 [bar] 714 239 141 44 43 23 13.5 10.3 10.7 10.5 10.7 10.7 10.5 10.6 10.7 10.8 10.7 10.8 10.7 11.0 Max. Spigot Min. L [mm] 28.5 33.5 49.0 49.0 49.0 58.5 59.0 65.0 71.0 78.0 89.0 103.0 L [mm] 31.0 36.0 52.0 52.0 52.0 61.5 62.0 68.0 74.0 81.0 93.0 106.0 * Up to 93°C. Quick-Lock® dimensions Nominal Length Pipe Max. Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 Insertion Depth (Ds) [mm] 27 32 46 46 46 57 57 64 70 76 89 102 Sd [mm] 32.6 47.5 59.2 87.6 112.5 139.5 166.2 217.1 271.3 322.2 353.8 404.1 Spigot Diameter Min. Sd [mm] 32.9 47.8 59.6 88.0 112.9 139.9 166.6 217.5 271.7 322.6 354.2 404.5 Dimensions for Quick-Lock Spigots for bonding HD Flanges. 450 500 600 700 750 800 900 1000 Taper/Taper dimensions 18 20 24 28 30 32 36 40 Dia of Straight Spigot [Sd] 455.8 506.6 608.2 736.3 788.4 840.5 943.4 1051.4 111 111 127 152 165 178 163 230 Dimensions for adhesive Taper spigots for adhesive Taper/Taper joints. Nominal Pipe Size [mm] 450 500 600 700 750 800 900 1000 [inch] 18 20 24 28 30 32 36 40 Taper Angle Insertion Depth X [degrees] 2.5 2.5 3.5 1.75 1.75 1.75 1.75 1.75 Ds [mm] 114 127 178 178 178 178 203 410 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 8 of 28. Printed in The Netherlands. Nominal Spigot Nose Thickn. nose [mm] 4.6 5.0 3.8 6.4 4.2 8.9 5.6 8.1 Dia of Spigot at Nose Sd [mm] 443.0 492.2 586.3 712.9 758.4 817.8 911.3 1016.3 Span length Bondstrand 2000M. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Bondstrand 7000M. 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Single Span* [m] 2.6 2.9 3.1 3.5 4.0 4.3 4.5 5.1 5.8 6.3 6.5 7.0 7.4 7.7 8.5 9.3 9.6 10.0 10.5 11.1 2.5 2.9 3.1 3.5 4.0 4.3 4.5 5.0 5.7 6.2 6.4 6.9 7.3 7.7 8.4 9.3 9.6 9.9 10.5 11.1 MDA Contininuous Span* [m] 3.3 3.7 4.0 4.5 5.1 5.4 5.7 6.5 7.3 8.0 8.3 8.8 9.3 9.8 10.8 11.8 12.2 12.7 13.4 14.1 Single IPD Continuous Span* Span* [m] [m] 2.4 3.0 2.7 3.4 2.9 3.7 3.3 4.2 3.7 4.7 4.0 5.0 4.2 5.3 4.8 6.1 5.3 6.8 5.8 7.4 6.0 7.7 6.4 8.2 6.8 8.7 7.2 9.1 7.9 10.0 8.6 11.0 8.9 11.3 9.2 11.7 9.8 12.4 10.3 13.1 MDA 3.3 3.8 4.1 4.5 5.2 5.6 5.9 6.5 7.3 8.0 8.3 8.8 9.3 9.8 10.8 11.8 12.2 12.7 13.4 14.1 IPD 3.0 3.4 3.7 4.2 4.7 5.0 5.3 5.9 6.7 7.3 7.6 8.1 8.6 9.0 9.9 10.9 11.3 11.7 12.4 13.0 2.4 2.7 2.9 3.3 3.7 4.0 4.2 4.7 5.3 5.7 6.0 6.4 6.7 7.1 7.8 8.6 8.9 9.2 9.7 10.3 * Span recommendations are based on pipes filled with water having a density of 1000 kg/m3 and include no provisions for weights caused by valves, flanges or other heavy objects. Elbows 90º Quick-Lock Taper/Taper Filament-wound 90º elbows with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends for adhesive bonding. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Laying Length (LL) [mm] 65 81 76 114 152 195 229 305 381 457 359 397 458 508 584 711 762 813 915 1040 Overall Length (OL) [mm] 92 113 122 160 198 252 286 369 451 533 448 499 572 635 762 889 940 991 1118 1450 Max. Working Pressure [bar] 20 20 20 20 20 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.3 0.4 0.5 1.1 1.6 2.7 3.6 6.8 11.0 18.0 26.0 31.0 53.0 65.0 122.0 205.0 243.0 330.0 417.0 489.0 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 9 of 28. Printed in The Netherlands. Elbows ANSI 90º short radius Filament-wound 90° elbows with integral Quick-Lock male ends.* Nominal Pipe Size [mm] 50 80 100 150 200 250 300 [inch] 2 3 4 6 8 10 12 Laying Length (LL) [mm] 110 135 160 198 224 275 300 Maximum Working Pressure [bar] 12 12 12 12 12 12 12 Average Weight Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.4 0.7 1.0 2.4 3.9 6.3 13.3 * Also available with flanges. Elbows 45º Filament-wound 45° Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends for adhesive bonding. Taper/Taper Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 Elbows ANSI 45º Filament-wound 45°elbows with integral Quick-Lock male ends.* Quick-Lock Nominal Pipe Size [mm] 50 80 100 150 200 250 300 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 [inch] 2 3 4 6 8 10 12 Laying Length (LL) [mm] 22 29 35 51 64 84 95 127 159 191 121 137 191 210 252 295 322 337 400 450 Laying Length (LL) [mm] 60 71 97 121 134 159 186 * Also available with flanges. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 10 of 28. Printed in The Netherlands. Overall Length (OL) [mm] 49 61 81 97 110 141 152 191 229 267 210 239 305 337 430 473 500 515 603 860 Maximum Working Pressure [bar] 12 12 12 12 12 12 12 [kg] 0.2 0.3 0.4 0.8 1.1 1.8 2.4 4.3 7.3 11.0 17.0 20.0 33.0 40.0 82.0 140.0 164.0 283.0 283.0 334.0 Average Weight [kg] 0.2 0.4 0.9 1.9 3.9 8.3 10.0 Elbows 22½º Filament-wound 22½°elbows with integral Quick-Lock socket ends for adhesive bonding. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 Equal Tees [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 Taper/Taper Overall Length (OL) [mm] 36 41 59 67 75 100 100 121 137 152 172 191 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.1 0.2 0.5 0.7 1.0 1.4 1.9 3.9 5.9 10.4 12.0 14.0 Filament-wound equal Tee with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends for adhesive bonding. Nominal Pipe Size Quick-Lock Laying Length (LL) [mm] 9 9 13 21 29 43 43 57 67 76 83 89 [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Laying Length total run (LL1) [mm] 54 60 128 172 210 254 286 356 432 508 534 584 648 712 838 964 1016 1090 1220 1416 Overall Length total run (OL1) [mm] 108 124 220 264 302 368 400 484 572 660 712 788 876 966 1194 1320 1372 1446 1626 2236 Laying Length branch (LL2) [mm] 27 30 64 86 105 127 143 178 216 254 267 292 324 356 419 482 508 545 610 708 Overall Length branch (OL2) [mm] 54 62 110 132 151 184 200 242 286 330 356 394 438 483 597 660 686 723 813 1118 Maximum Working Pressure Average Weight [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 [kg] 0.2 0.4 1.0 1.8 2.5 5.0 6.7 10.0 18.0 29.0 37.0 56.0 69.0 92.0 168.0 285.0 337.0 459.0 581.0 686.0 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 11 of 28. Printed in The Netherlands. Reducing Tees Filament-wound standard and fabricated reducing tees with integral Quick-Lock (1-16 inch) socket ends for adhesive bonding. Nominal Pipe Size (runxrunxbranch) Standard Fabricated [mm] 40x40x25 50x50x25 50x50x40 80x80x25 80x80x40 80x80x50 100x100x25 100x100x40 100x100x50 100x100x80 125x125x50 125x125x80 125x125x100 150x150x25 150x150x40 150x50x50 150x150x80 150x150x100 150x150x125 200x200x25 200x200x40 200x200x50 200x200x80 200x200x100 200x200x125 200x200x150 250x250x25 250x250x40 250x250x50 250x250x80 250x250x100 250x250x125 250x250x150 250x250x200 300x300x25 300x300x40 300x300x50 300x300x80 300x300x100 300x300x150 300x300x200 300x300x250 350x350x25 350x350x40 350x350x50 350x350x80 350x350x100 350x350x150 350x350x200 350x350x250 350x350x300 400x400x25 400x400x40 400x400x50 400x400x80 400x400x100 400x400x150 400x400x200 400x400x250 400x400x300 400x400x350 [inch] 1½x1½x1 2x2x1 2x2x1½ 3x3x1 3x3x1½ 3x3x2 4x4x1 4x4x1½ 4x4x2 4x4x3 5x5x2 5x5x3 5x5x4 6x6x1 6x6x1½ 6x6x2 6x6x3 6x6x4 6x6x5 8x8x1 8x8x1½ 8x8x2 8x8x3 8x8x4 8x8x5 8x8x6 10x10x1 10x10x1½ 10x10x2 10x10x3 10x10x4 10x10x5 10x10x6 10x10x8 12x12x1 12x12x1½ 12x12x2 12x12x3 12x12x4 12x12x6 12x12x8 12x12x10 14x14x1 14x14x1½ 14x14x2 14x14x3 14x14x4 14x14x6 14x14x8 14x14x10 14x14x12 16x16x1 16x16x1½ 16x16x2 16x16x3 16x16x4 16x16x6 16x16x8 16x16x10 16x16x12 16x16x14 Laying Length (LL1) Overall Length (OL1) Laying Length (LL2) [mm] 30 64 64 86 86 86 72 89 105 105 127 127 127 83 101 143 143 143 143 84 101 116 178 178 178 178 83 100 115 115 216 216 216 216 84 102 117 117 254 254 254 254 81 99 114 114 114 267 267 267 267 85 103 118 118 118 292 292 292 292 292 [mm] 62 110 110 132 132 132 118 136 151 151 184 184 184 140 158 200 200 200 200 148 165 180 242 242 242 242 153 170 185 185 286 286 286 286 160 178 193 193 330 330 330 330 170 188 203 203 203 356 356 356 356 187 205 220 220 220 394 394 394 394 394 [mm] 30 57 57 76 76 76 194 194 89 98 102 111 118 221 221 114 124 130 136 245 246 246 149 162 168 168 273 273 273 273 184 194 194 203 298 298 298 298 206 219 229 241 314 314 314 314 314 244 254 267 279 338 338 338 338 338 264 273 283 295 292 half run half run branch Overall Maximum Average Length Working Weight (OL2) Pressure branch [mm] 57 84 89 103 108 122 221 226 135 144 148 157 164 248 253 160 170 176 193 272 278 292 195 208 225 225 300 305 320 320 230 251 251 267 325 330 344 344 252 276 293 311 341 346 361 361 361 301 318 337 355 365 370 384 384 384 321 337 353 371 381 [bar] 20 20 20 20 20 20 20 20 20 20 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees; Filament-wound standard and fabricated reducing tees with integral. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 12 of 28. Printed in The Netherlands. [kg] 0.6 0.9 1.0 1.6 1.6 1.7 7.5 9.0 2.1 2.3 3.4 4.0 4.6 11.7 13.8 5.4 6.0 6.2 6.5 15.0 17.5 19.9 9.1 9.7 10.6 11.4 18.1 21.0 24.0 24.0 14.8 15.2 15.5 16.5 21.2 25.0 29.0 29.0 21.0 22.0 23.0 24.0 24.0 28.0 31.0 31.0 31.0 29.0 30.0 32.0 34.0 29.0 33.0 37.0 37.0 37.0 37.0 38.0 41.0 45.0 49.0 Reducing Tees Taper/Taper (18-40 inch) socket ends for adhesive bonding. Nominal Pipe Size (runxrunxbranch) [mm] 450x450x25 450x450x40 450x450x50 450x450x80 450x450x100 450x450x150 450x450x200 450x450x250 450x450x300 450x450x350 450x450x400 500x500x25 500x500x40 500x500x50 500x500x80 500x500x100 500x500x150 500x500x250 500x500x300 500x500x350 500x500x400 500x500x450 600x600x25 600x600x40 600x600x50 600x600x80 600x600x100 600x600x150 600x600x200 600x600x250 600x600x300 600x600x350 600x600x400 600x600x450 600x600x500 700x700x25 700x700x40 700x700x50 700x700x80 700x700x100 700x700x150 700x700x350 700x700x400 700x700x450 700x700x500 700x700x600 750x750x25 750x750x40 750x750x50 750x750x80 750x750x100 750x750x150 750x750x300 750x750x350 750x750x400 750x750x450 750x750x500 750x750x600 [inch] 18x18x1 18x18x1½ 18x18x2 18x18x3 18x18x4 18x18x6 18x18x8 18x18x10 18x18x12 18x18x14 18x18x16 20x20x1 20x20x1½ 20x20x2 20x20x3 20x20x4 20x20x6 20x20x10 20x20x12 20x20x14 20x20x16 20x20x18 24x24x1 24x24x1½ 24x24x2 24x24x3 24x24x4 24x24x6 24x24x8 24x24x10 24x24x12 24x24x14 24x24x16 24x24x18 24x24x20 28x28x1 28x28x1½ 28x28x2 28x28x3 28x28x4 28x28x6 28x28x14 28x28x16 28x28x18 28x28x20 28x28x24 30x30x1 30x30x1½ 30x30x2 30x30x3 30x30x4 30x30x6 30x30x12 30x30x14 30x30x16 30x30x18 30x30x20 30x30x24 Laying Length (LL1) Overall Length (OL1) Laying Length (LL2) [mm] 88 88 88 100 113 138 324 324 324 324 324 88 88 88 100 113 138 356 356 356 356 356 88 88 88 100 113 138 419 419 419 419 419 419 419 88 88 88 100 113 138 482 482 482 482 482 88 88 88 100 113 138 508 508 508 508 508 508 [mm] 202 202 202 214 227 252 438 438 438 438 438 215 215 215 227 240 265 483 483 483 483 483 266 266 266 278 291 316 597 597 597 597 597 597 597 266 266 266 278 291 316 660 660 660 660 660 266 266 266 278 291 316 686 686 686 686 686 686 [mm] 358 358 358 358 358 367 306 319 319 317 319 382 382 382 382 382 391 344 345 343 344 350 430 430 430 430 430 439 412 386 408 394 395 413 406 491 491 491 491 491 500 490 500 500 506 506 516 516 516 516 516 525 756 722 698 488 495 481 half run half run branch Overall Maximum Average Length Working Weight (OL2) Pressure branch [mm] 385 390 404 404 404 424 370 389 395 406 421 409 414 428 428 428 448 414 421 432 446 464 457 462 476 476 476 496 476 456 484 483 497 527 533 518 523 537 537 537 557 579 602 614 633 684 543 548 562 562 562 582 832 811 800 602 622 659 [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 [kg] 31.0 31.0 22.0 35.0 38.0 45.0 53.0 60.0 67.0 66.0 69.0 35.0 35.0 36.0 39.0 43.0 50.0 77.0 82.0 85.0 85.0 89.0 51.0 51.0 52.0 56.0 61.0 69.0 78.0 85.0 85.0 101.0 123.3 137.0 156.0 59.0 59.0 59.0 64.0 70.0 80.0 147.0 166.0 189.0 210.0 252.0 63.0 63.0 63.0 69.0 74.0 85.0 118.0 157.0 178.0 202.0 225.0 270.0 Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 13 of 28. Printed in The Netherlands. Reducing Tees (C’tnd) Filament-wound standard and fabricated reducing tees with integral Taper/Taper (18-40 inch) socket ends for adhesive bonding. Nominal Pipe Size (runxrunxbranch) Standard Fabricated [mm] [inch] 800x800x25 32x32x1 800x800x40 32x32x1½ 800x800x50 32x32x2 800x800x80 32x32x3 800x800x100 32x32x4 800x800x150 32x32x6 800x800x500 32x32x20 800x800x600 32x32x24 800x800x700 32x32x28 800x800x750 32x32x30 900x900x25 36x36x1 900x900x40 36x36x1½ 900x900x50 36x36x2 900x900x80 36x36x3 900x900x100 36x36x4 900x900x150 36x36x6 900x900x400 36x36x16 900x900x450 36x36x18 900x900x500 36x36x20 900x900x600 36x36x24 900x900x700 36x36x28 900x900x750 36x36x30 1000x1000x400 40x40x1 1000x1000x45040x40x1½ 1000x1000x500 40x40x2 1000x1000x600 40x40x3 1000x1000x60040x40x24 1000x1000x70040x40x28 1000x1000x75040x40x30 1000x1000x80040x40x32 1000x1000x90040x40x36 Laying Length (LL1) Overall Length (OL1) Laying Length (LL2) [mm] 88 88 88 100 113 138 545 545 545 545 88 88 88 100 113 138 610 610 610 610 610 610 120 120 120 132 708 708 708 708 708 [mm] 266 266 266 278 291 316 723 723 723 723 291 291 291 303 316 341 813 813 813 813 813 813 530 530 530 542 1118 1118 1118 1118 1118 [mm] 541 541 541 541 541 550 523 523 532 534 591 591 591 591 591 600 563 563 563 541 570 584 641 641 641 641 593 632 633 652 652 half run half run branch Overall Maximum Average Length Working Weight (OL2) Pressure branch [mm] 568 573 587 587 587 607 650 701 710 712 618 623 637 637 637 657 665 677 690 719 748 762 668 673 687 687 771 810 811 830 855 [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Note: Regular numbers are filament wound tees; Italic numbers are fabricated tees. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 14 of 28. Printed in The Netherlands. [kg] 66.0 67.0 67.0 73.0 79.0 90..0 257.0 310.0 348.0 387.0 78.0 78.0 78.0 85.0 92.0 105.0 270.0 290.0 323.0 387.0 459.0 484.0 92.0 92.0 92.0 100.0 457.0 541.0 571.0 605.0 634.0 Fabricated Reducing Tees with Flanged Branch Fabricated Reducing tees with integral Quick-Lock (1-16 inch) socket ends and flanged branch. Nominal Pipe Size (runxrunxbranch) [mm] 100x100x25 100x100x40 150x150x25 150x150x40 200x200x25 200x200x40 200x200x50 250x250x25 250x250x40 250x250x50 250x250x80 300x300x25 300x300x40 300x300x50 300x300x80 350x350x25 350x350x40 350x350x50 350x350x80 350x350x100 400x400x25 400x400x40 400x400x50 400x400x80 400x400x100 [inch] 4x4x1 4x4x1½ 6x6x1 6x6x1½ 8x8x1 8x8x1½ 8x8x2 10x10x1 10x10x1½ 10x10x2 10x10x3 12x12x1 12x12x1½ 12x12x2 12x12x3 14x14x1 14x14x1½ 14x14x2 14x14x3 14x14x4 16x16x1 16x16x1½ 16x16x2 16x16x3 16x16x4 Laying Length (LL1) Overall Length (OL1) Laying Length (LL2) [mm] 72 89 83 101 84 101 116 83 100 115 115 84 102 117 117 81 99 114 114 114 85 103 118 118 118 [mm] 118 135 140 158 148 165 180 153 170 185 185 160 178 193 193 170 188 203 203 203 187 205 220 220 220 [mm] 225 230 252 257 276 281 295 303 308 322 323 329 334 348 349 344 349 363 369 364 369 374 388 389 389 half run half run branch Maximum Average Working Weight Pressure with flange [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 CL150 [kg] 8.0 9.7 12.2 14.5 15.5 18.2 21.4 18.6 22.0 25.6 26.3 22.3 26.1 30.2 30.9 24.3 28.4 32.7 33.4 34.2 29.1 33.8 38.5 39.2 39.9 Note: Other sizes, or multiple size branched tees available on request. Please contact Ameron. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 15 of 28. Printed in The Netherlands. Fabricated Reducing Tees with Flanged Branch Fabricated Reducing tees with integral Taper/Taper (18-40 inch) socket ends and flanged branch. Nominal Pipe Size (runxrunxbranch) [mm] [inch] 450x450x25 18x18x1 450x450x40 18x18x1½ 450x450x50 18x18x2 450x450x80 18x18x3 450x450x100 18x18x4 450x450x150 18x18x6 500x500x25 20x20x1 500x500x40 20x20x1½ 500x500x50 20x20x2 500x500x80 20x20x3 500x500x100 20x20x4 500x500x150 20x20x6 600x600x25 24x24x1 600x600x40 24x24x1½ 600x600x50 24x24x2 600x600x80 24x24x3 600x600x100 24x24x4 600x600x150 24x24x6 700x700x25 28x28x1 700x700x40 28x28x1½ 700x700x50 28x28x2 700x700x80 28x28x3 700x700x100 28x28x4 700x700x150 28x28x6 750x750x25 30x30x1 750x750x40 30x30x1½ 750x750x50 30x30x2 750x750x80 30x30x3 750x750x100 30x30x4 750x750x150 30x30x6 800x800x25 32x32x1 800x800x40 32x32x1½ 800x800x50 32x32x2 800x800x80 32x32x3 800x800x100 32x32x4 800x800x150 32x32x6 900x900x25 36x36x1 900x900x40 36x36x1½ 900x900x50 36x36x2 900x900x80 36x36x3 900x900x100 36x36x4 900x900x150 36x36x6 1000x1000x25 40x40x1 1000x1000x4040x40x1½ 1000x1000x50 40x40x2 1000x1000x80 40x40x3 Laying Length (LL1) Overall Length (OL1) Laying Length (LL2) [mm] 88 88 88 100 113 138 88 88 88 100 113 138 88 88 88 100 113 138 88 88 88 100 113 138 88 88 88 100 113 138 88 88 88 100 113 138 88 88 88 100 113 138 120 120 120 132 [mm] 202 202 202 214 227 252 215 215 215 227 240 265 266 266 266 278 291 316 266 266 266 278 291 316 266 266 266 278 291 316 266 266 266 278 291 316 291 291 291 303 316 341 530 530 530 542 [mm] 388 394 408 409 409 430 412 418 432 433 433 454 460 467 480 481 481 502 521 527 541 542 542 563 546 552 566 567 567 588 571 576 590 590 590 610 621 627 641 642 642 663 672 677 691 692 half run half run branch Maximum Average Working Weight Pressure with flange [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 CL150 [kg] 31.7 32.0 33.0 37.0 41.2 49.9 35.8 36.0 37.0 41.4 45.9 54.8 51.9 52.0 53.0 58.2 63.4 73.7 59.3 59.3 60.5 66.5 72.6 84.5 63.2 63.4 64.4 70.8 77.1 89.8 66.9 67.2 68.1 74.9 81.6 94.9 78.3 78.6 79.6 87.0 94.4 109.2 92.3 92.6 93.7 103.0 Note: Other sizes, or multiple size branched tees available on request. Please contact Ameron. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 16 of 28. Printed in The Netherlands. Bushing Saddles Filament-wound pipe saddles with stainless steel, 1/2 inch and 3/4 inch threaded bushings.* Nominal Pipe Size [mm] [inch] 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 Angle α [degree] 180 180 180 180 180 180 180 180 180 180 90 90 90 Saddle Length (B) [mm] 100 100 100 100 100 100 100 100 100 100 100 100 100 Saddle Maximum Thickn. Working (ts) Pressure [mm] [bar] 14 16 14 16 14 16 14 16 14 16 14 16 14 16 14 12 14 12 14 12 14 12 14 12 14 12 Average Weight [kg] 0.5 0.6 0.8 0.9 1.0 1.2 1.6 1.9 2.1 2.5 3.3 3.7 4.4 Required Adhesive Kits [3 Oz] [6 Oz] 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 * Consult Ameron for other type material, or other sized bushings. 45º Laterals Filament-wound 45° laterals with integral Quick-Lock socking ends. Nominal Pipe Size [mm] [inch] 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 Laying Length (LL1) [mm] 64 76 76 89 89 114 127 140 140 140 Overall Length (OL1) [mm] 110 122 122 146 146 178 197 216 229 242 Laying Length (LL2) [mm] 203 254 305 337 368 445 521 622 622 622 Overall Length (OL2) [mm] 249 300 351 394 425 509 591 698 711 724 Maximum Working Pressure [bar] 16 16 16 16 16 16 12 12 12 12 Average Weight [kg] 1.6 3.0 3.9 5.8 6.8 12.0 21.0 30.0 39.0 54.0 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 17 of 28. Printed in The Netherlands. Concentric Reducers Filament-wound concentric reducers with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends. Nominal Pipe Size (runxrun) Quick-Lock Taper/Taper [mm] 40x25 50x25 50x40 80x40 80x50 100x50 100x80 125x80 125x100 150x80 150x100 150x125 200x100 200x125 200x150 250x150 250x200 300x200 300x250 350x250 350x300 400x300 400x350 450x400 500x400 500x450 600x400 600x450 600x500 700x400 700x450 700x500 700x600 750x400 750x450 750x500 750x600 750x700 800x400 800x450 800x500 800x600 800x700 800x750 900x500 900x600 900x700 900x750 1000x900 [inch] 1½x1 2x1 2x1½ 3x1½ 3x2 4x2 4x3 5x3 5x4 6x3 6x4 6x5 8x4 8x5 8x6 10x6 10x8 12x8 12x10 14x10 14x12 16x12 16x14 18x16 20x16 20x18 24x16 24x18 24x20 28x16 28x18 28x20 28x24 30x16 30x18 30x20 30x24 30x28 32x16 32x18 32x20 32x24 32x28 32x30 36x20 36x24 36x28 36x30 40x36 Laying Length (LL) [mm] 32 64 32 76 54 76 73 74 74 97 94 110 138 126 98 117 105 149 137 184 178 165 152 103 225 123 453 353 230 765 661 542 311 876 775 653 422 111 1023 920 798 570 259 148 1029 799 487 375 285 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 18 of 28. Printed in The Netherlands. Overall Length (OL) [mm] 91 137 110 154 146 168 165 177 177 200 197 224 248 247 219 244 239 289 283 343 343 343 343 319 454 364 733 645 535 1045 953 847 667 1156 1067 958 778 467 1303 1212 1103 926 615 504 1359 1180 868 756 898 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.2 0.3 0.5 0.5 0.5 1.1 0.9 1.4 1.5 1.8 1.8 1.8 2.9 2.8 2.7 3.7 3.6 5.0 4.6 7.2 7.3 8.9 9.0 12.7 22.6 18.9 48.4 44.3 38.5 79.0 74.0 69.0 67.3 111.6 106.6 99.6 87.2 57.2 139.4 125.4 108.8 94.3 81.8 70.9 210.0 176.1 140.2 125.9 182.0 Eccentric Reducers Filament-wound Eccentric Reducers with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends. Nominal Pipe Size (runxrun) Quick-Lock Taper/Taper [mm] 40x25 50x25 50x40 80x40 80x50 100x50 100x80 125x100 150x80 150x100 150x125 200x100 200x150 250x150 250x200 300x200 300x250 350x250 350x300 400x300 400x350 450x300 450x350 450x400 500x400 500x450 600x400 600x450 600x500 750x400 900x400 Laying Length [inch] 1½x1 2x1 2x1½ 3x1½ 3x2 4x2 4x3 5x4 6x3 6x4 6x5 8x4 8x6 10x6 10x8 12x8 12x10 14x10 14x12 16x12 16x14 18x12 18x14 18x16 20x16 20x18 24x16 24x18 24x20 30x24 36x24 (LL) [mm] 56 100 44 150 108 200 93 101 293 200 100 390 190 392 202 390 190 308 118 306 188 450 322 197 324 197 580 450 325 451 832 Overall Eccentricity Length (OL) [mm] 115 173 122 228 200 292 185 204 396 303 214 500 311 519 336 530 336 467 283 484 379 640 525 413 553 438 860 742 630 807 1213 (X) [mm] 7 13 6 20 14 27 12 14 39 27 13 52 25 53 27 53 26 42 16 41 25 63 43 18 39 22 93 73 48 86 161 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.2 0.3 0.5 0.5 0.5 1.1 0.9 1.5 1.8 1.8 1.8 2.9 2.7 3.7 3.6 5.0 4.6 7.2 7.3 8.9 9.0 15.6 14.2 12.7 23.0 18.9 48.0 44.0 39.0 87.0 176.0 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 19 of 28. Printed in The Netherlands. Heavy-Duty Flanges Filament-wound Heavy-Duty flanges with integral Quick-Lock (1-40 inch) socket end. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Laying Length (LL) [mm] 3 3 4 5 5 5 6 6 6 5 8 8 10 10 11 14 14 14 14 15 Overall Maximum Length Working (OL) Pressure [mm] 29 35 51 51 51 62 63 70 76 81 97 110 114 121 138 165 178 192 178 245 [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average weight DIN 2632DIN 2633 ANSI ANSI B16.5 B16.5 CL.150 CL.300 PN10 PN16 [kg] [kg] [kg] [kg] 0.5 0.6 0.5 0.5 1.1 1.1 1.0 1.0 1.3 1.7 1.8 1.8 1.8 2.6 2.4 2.4 2.8 3.8 2.7 2.7 3.8 5.4 4.0 4.0 4.5 6.7 4.9 4.9 5.0 9.9 7.1 6.9 9.5 13.2 9.1 9.8 14.5 19.2 11.2 12.7 20.5 29.8 18.6 20.5 27.0 40.0 25.0 27.4 32.0 40.0 58.0 73.0 88.0 112.0 116.0 162.0 - Note: Other drillings may be possible. Please consult Ameron. 1) 2) 3) Hub Flanges Full-face elastomeric gaskets may be used suitable for the service pressure, service temperature and fluid. Shore A durometer hardness of 60 +5 is recommended (3 mm thick). Compressed fibre gaskets (3 mm thick), compatible with pressure, temperature and medium may also be used. Mechanical properties should be in accordance with DIN 3754 (IT 400) or equal. For maximum bolt torque refer to the appropriate Bondstrand literature. A torque-wrench must be used, since excessive torque may result in flange damage. Size 18-40 inch can be bonded directly to a fitting by using a Quick-Lock to Taper/Taper transition nipple. For bonding to pipe, a Quick Lock (straight) spigot has to be shaved on the pipe. Filament-wound Hubbed flanges with integral Quick-Lock (1-36 inch) socket end. Nominal DIN 2633 Pipe Size [mm] [inch] 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 Laying Overall Length Length Thickness (LL) [mm] 4 5 5 5 6 6 6 5 8 8 10 10 11 14 14 14 14 (OL) [mm] 51 51 51 62 63 70 76 81 97 110 114 121 138 165 178 192 178 Flange (E) [mm] 30 30 33 47 47 54 54 56 72 85 89 96 113 114 121 124 140 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 20 of 28. Printed in The Netherlands. Maximum Working Pressure [bar] 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 Average weight ANSI B16.5 CL.150 [kg] 0.9 1.5 2.2 3.7 3.7 6.2 8.4 12.3 17.3 26.0 30.0 35.0 48.0 67.0 77.0 85.0 93.0 ANSI B16.5 CL.300 [kg] 1.1 1.8 2.9 4.9 5.4 8.4 11.1 15.3 22.6 32.9 - DIN 2632 PN10 [kg] 1.0 1.6 2.1 3.6 3.9 6.0 7.6 9.0 14.1 20.6 - PN16 [kg] 1.0 1.1 2.1 3.6 3.9 6.0 8.2 10.2 15.5 22.6 - Stub-end Flanges Quick-Lock Taper/Taper Filament-wound O-ring sealed stub-end flanges with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends with loose steelrings. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Laying Length (LL) [mm] 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 20 Overall Length (OL) [mm] 37 42 56 56 56 67 67 74 80 86 98 112 134 147 198 198 198 198 223 430 Face Diameter (RF) [mm] 51 73 92 127 157 186 216 270 324 378 413 470 532 580 674 800 850 900 1000 1100 Ring to Face (H) [mm] 10 10 10 10 16 16 16 16 23 23 27 27 35 39 47 51 46 48 53 58 Maximum Average Working Weight Pressure Stub-end [bar] [kg] 16 0.1 16 0.2 16 0.2 16 0.4 16 0.6 16 1.0 16 1.2 16 1.8 16 2.5 16 3.3 16 3.8 16 5.7 16 11.1 16 13.2 16 17.2 16 21.0 16 24.4 16 21.8 16 30.8 16 470 Note: Up to 12 bar flat faced stub-ends suitable for elastomeric gaskets can be used. From 12 bar and above O-ring sealed stub-ends should be used. Make sure that when using O-ring sealed stub-end, its counter flange is compatible, e.g. use a flat faced stub-end (without O-ring groove) or another flat surface flange as counter flange. Steel Ring Flange for Stub-end Nominal ANSI Average ANSI Average DIN 2632 Average DIN 2633 Average Pipe B16.5 Weight B16.5 Weight Weight Weight Size CLASS.150 CLASS.300 PN 10 PN 16 (D) (D) (D) (D) [mm] [inch] [mm] [kg] [mm] [kg] [mm] [kg] [mm] [kg] 25 1 14.3 0.8 17.5 1.3 16 1.0 16 1.0 40 1½ 17.5 1.2 20.6 2.3 16 1.7 16 1.7 50 2 19.0 1.8 22.2 2.5 18 2.2 18 2.2 80 3 23.8 3.2 28.6 4.8 20 3.0 20 3.0 100 4 23.8 4.2 31.7 7.0 20 3.1 20 3.1 125 5 23.8 4.4 34.9 9.5 22 3.6 23 3.8 150 6 25.5 5.2 36.5 12.2 22 4.9 23 5.1 200 8 28.8 8.5 41.3 18.3 25 7.1 27 7.3 250 10 35.6 13.5 47.6 26.0 28 9.3 32 11.8 300 12 40.0 23.0 50.8 38.7 29 10.7 35 15.4 350 14 41.6 32.0 54.0 56.3 36 21.3 40 26.3 400 16 47.9 42.0 58.2 70.1 40 26.6 44 33.0 450 18 50.2 39.7 63.6 86.5 42 27.2 50 40.9 500 20 52.0 50.6 66.5 104.1 45 34.7 54 59.8 600 24 63.7 86.1 78.4 182.9 52 55.3 63 72.2 700 28 69.0 100.5 95.6 213.4 57 78.8 59 101.9 750 30 71.6 117.0 99.9 229.3 800 32 76.9 153.5 106.2 289.0 62 95.3 66 105.7 900 36 85.4 197.2 117.7 424.1 66 111.8 71 125.1 1000 40 93.7 102.8 74 82 Note: Other materials and/or drillings are available. Please consult Ameron. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 21 of 28. Printed in The Netherlands. Blind Flanges Filament-wound blind flanges. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 Flange Thickness (D) [mm] 25 25 30 30 35 35 40 45 50 60 65 70 70 70 85 85 90 95 100 Maximum Average weight Working ANSI B16.5 ANSI B16.5 Pressure CLASS 150 CLASS 300 [bar] [kg] [kg] 16 0.4 0.5 16 0.5 0.9 16 0.7 1.2 16 1.1 1.9 16 1.7 3.6 16 2.6 3.8 16 2.9 5.7 16 5.2 9.2 16 7.2 13.8 16 11.4 23.0 16 16.4 31.0 16 23.0 41.0 16 43.0 52.0 16 52.0 63.0 16 85.0 106.0 16 110.0 136.0 16 132.0 160.0 16 145.0 184.0 16 206.0 239.0 Average weight DIN 2632 DIN 2633 PN 10 PN 16 [kg] [kg] 0.4 0.5 0.7 0.8 1.1 1.2 1.6 1.7 2.6 2.7 3.0 3.1 4.4 4.6 7.1 7.3 10.6 11.5 16.3 17.8 23.0 25.0 31.0 33.0 40.0 43.0 48.0 54.0 79.0 91.0 104.0 106.0 129.0 116.0 155.0 125.0 191.0 192.0 Note: Other drillings are available. Please consult Ameron. Couplings Quick-Lock Taper/Taper Filament-wound couplings with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket ends. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Laying Length (LL) [mm] 10 10 10 10 10 10 10 10 10 10 19 19 70 70 70 70 70 70 70 70 Overall Length (OL) [mm] 64 74 102 102 102 124 124 138 150 162 197 223 298 324 426 426 426 426 476 890 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 22 of 28. Printed in The Netherlands. Outside Diameter (OD) [mm] 42 58 72 100 129 153 183 235 289 340 372 422 460 514 619 742 795 848 950 1057 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.1 0.1 0.3 0.4 0.6 0.9 1.1 1.7 2.3 2.8 4.6 7.2 10.7 13.0 18.8 23.5 24.5 27.0 34.5 40.7 Nipples Filament-wound nipples with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) male ends. Quick-Lock Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 Taper/Taper [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Laying Length (LL) [mm] 57 67 95 95 95 117 118 130 143 156 184 210 278 304 406 406 406 406 456 870 Gap* [mm] 3 3 3 3 3 3 3 3 3 3 3 3 50 50 50 50 50 50 50 50 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 Average Weight [kg] 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.9 1.1 3.1 4.4 5.9 7.8 12.0 21.0 22.0 24.0 36.0 51.0 * Remaining gap after bonding. Transition Nipples Filament-wound transition nippels with integral Taper/Taper (18-40 inch) male ends. Nominal Pipe Size [mm] 450 500 600 700 750 800 900 1000 [inch] 18 20 24 28 30 32 36 40 Laying Length (LL) [mm] 238 263 338 374 386 400 410 685 Gap* [mm] 19 25 33 44 44 44 43 45 Maximum Working Pressure [bar] 16 16 16 16 16 16 16 16 Average Weight [kg] 6 7 9 15 22 30 40 45 * Remaining gap after bonding. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 23 of 28. Printed in The Netherlands. Support Saddles α α Filament-wound pipe saddles for wear, support and anchor. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Saddle Angle α [degree] 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 180 Saddle Saddle Thickn. Weight ts B=100mm [mm] [kg] 14 0.2 14 0.3 14 0.4 14 0.5 14 0.7 14 0.8 14 0.9 14 1.1 14 1.5 14 1.8 14 2.0 14 2.4 16 16 16 16 16 16 16 16 - Required Saddle Adhesive Weight Kits B=150mm [3 and 6Oz] [kg] 1 0.3 1 0.5 1 0.6 1 0.8 1 1.1 1 1.2 1 1.4 1 1.7 1 1 2.3 1 1 2.7 1 1 3.0 2 3.6 3.2 3.6 4.3 5.1 5.5 5.8 6.5 8.2 Required Adhesive Kits [3 and 6 Oz] 1 1 1 1 1 1 1 1 1 1 2 1 2 1 2 3 2 2 2 3 3 3 4 4 Notes: 1) Filament-wound support saddles are intended for protection of pipe at supports and clamps, as well as for anchoring purposes. Support and anchor saddles are standard 180°. Saddles are supplied in standard lengths of 100 mm and 150 mm. 2) For special saddle -lengths, -thickness and/or angles consult Ameron. 3) Wear saddles are standard 90°. Weights of 90° degree saddles are 50% of value shown. Grounding Saddles Filament-wound pipe saddles for grounding in conductive piping systems. Nominal Pipe Size [mm] [inch] 25 1 40 1½ 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 750 30 800 32 900 36 1000 40 Saddle Angle α [degree] 90 90 90 90 90 90 90 45 45 45 45 45 221/2 221/2 221/2 221/2 221/2 221/2 221/2 221/2 Saddle Length B [mm] 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 Saddle Thickness ts [mm] 14 14 14 14 14 14 14 14 14 14 14 14 16 16 16 16 16 16 16 16 Average Saddle Weight [kg] 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.3 0.3 0.4 0.4 0.4 0.5 Notes: 1) Bondstrand conductive adhesive should be used for mounting. 2) Saddles are supplied with integrated stainless steel cable with a length of 600 mm. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 24 of 28. Printed in The Netherlands. Required Adhesive Kits [3Oz] 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 3 Bell Mouths Filament-wound bell mouths with adhesive-bonded HD-flange. Nominal Pipe Size [mm] [inch] 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 Overall Length (OL) [mm] 269 274 289 323 324 533 594 569 605 588 627 724 831 Length of Bell Mouth (H1) 115 120 135 158 158 340 395 365 375 345 360 450 540 Internal Diameter (D1) [mm] 110 220 275 400 450 750 850 850 850 850 900 1100 1300 Internal Diameter (D2) [mm] 110 220 275 400 450 418 518 510 510 510 548 548 648 Average Weight* [kg] 3.1 5.0 8.4 12.7 14.7 26.0 39.0 51.0 60.0 67.0 90.0 119.0 171.0 * Weights provided are for bell mouth with CL150 flange. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 25 of 28. Printed in The Netherlands. Assembly of double O-ring expansion joint Expansion Coupling Filament-wound Key-Lock expansion coupling with integral double O-ring Key-Lock female end one side and double O-ring female end on other side. Nominal Pipe Size [mm] [inch] 50 2 80 3 100 4 125 5 150 6 200 8 250 10 300 12 350 14 400 16 450 18 500 20 600 24 700 28 Laying Length (LL) [mm] 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Overall Length (OL) [mm] 222 222 222 264 270 337 356 410 430 450 416 433 479 560 O-ring Size Key Size Average Weight [mm] 7 x 59.7 7 x 88.3 7 x 113.7 9 x 135 10 x 161.3 10 x 225.5 12.5 x 302 12.5 x 342.3 12.5 x 342.3 12.5 x 393.1 15.0 x 445.0 15.0 x 490.0 18.0 x 580.0 20.0 x 685.0 [mm] 6 x 305 6 x 400 6 x 483 8 x 580 8 x 660 10 x 840 12 x 1270 15 x 1270 15 x 1360 18 x 1585 15x1750 15x1930 18x2240 20x2700 [kg] 1.3 1.7 3.5 4.6 6.6 15.4 19.9 21.0 25.0 32.0 27.0 32.0 52.0 99 Key-Lock Adapter for Expansion Coupling Filament-wound double O-ring male Key-Lock adapter with integral Quick-Lock (2-16 inch) or Taper/Taper (18-40 inch) socket end. Quick-Lock Nominal Pipe Size [mm] 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 Taper/Taper [inch] 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Laying Length (LL) [mm] 85 85 85 102 105 138 148 175 185 195 193 201 224 265 272 307 362 355 © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 26 of 28. Printed in The Netherlands. Overal Length (OL) [mm] 131 131 131 159 162 202 218 251 274 297 307 328 402 443 450 485 465 765 Pressure Weight [bar] 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 [kg] 0.4 0.6 0.9 1.6 1.8 5.1 11.8 14.6 10.7 15.9 19.5 23.5 25.0 29.0 34.0 42.0 50.0 64.0 Double O-ring Adapter for Expansion Coupling Filament-wound double O-ring male adapter with integral Quick-Lock (1-16 inch) or Taper/Taper (18-40 inch) socket end. Quick-Lock Nominal Pipe Size [mm] 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 Taper/Taper Adhesive [inch] 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Laying Length (LL) [mm] 85 85 85 102 105 138 148 175 185 195 193 201 224 265 272 307 362 355 Overall Length (OL) [mm] 131 131 131 159 162 202 218 251 274 297 307 328 402 443 450 485 465 765 Average Weight [cm3] 88.7 88.7 88.7 88.7 88.7 88.7 88.7 88.7 177.4 177.4 177.4 177.4 177.4 177.4 177.4 177.4 177.4 177.4 177.4 177.4 Required Adhesive Kit Size [Oz] 3 3 3 3 3 3 3 3 6 6 6 6 6 6 6 6 6 6 6 6 Minimum number of Adhesive Kits required per joint nr. 1/5 1/5 1/4 1/3 1/2 1 1 1 1 1 2 2 2 3 4 4 5 5 6 6 [kg] 0.4 0.7 0.9 1.6 1.8 5.1 11.8 14.6 10.7 15.9 19.5 23.5 25.0 29.0 34.0 42.0 50.0 64.0 Number of Adhesive Kits per joint. Nominal Pipe Size [mm] 25 40 50 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 [inch] 1 1½ 2 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 Notes: 1) Adhesive Kits should never be split. If remainder is not used for other joints made at the same time, the surplus must be discarded. 2) Required adhesive for saddles is shown in the dimension table of the respective saddles. 3) For type of adhesive to be used, please refer to the Bondstrand® Corrosion Guide. © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 27 of 28. Printed in The Netherlands. Engineering design & installation Consult de following literature for recommendations pertaining design, installation and use of Bondstrand pipe, fittings and flanges: Assembly Instructions for Quick-Lock adhesive-bonded joints Assembly Instructions for Taper/Taper adhesive-bonded joints Assembly Instructions for Bondstrand fiberglass flanges Bondstrand Corrosion Guide for fiberglass pipe and tubing Bondstrand Pipe Shaver Overview Bondstrand Marine Design Manual FP 170 FP 564 FP 196 FP 132 FP 599 FP 707 Please consult Ameron for the latest version of the above mentioned literature. Specials Note: Elbows with non-standard angles, non-standard drilled flanges, multi branch tees and special spools are available on request, please consult Ameron. Field testing Pipe system is designed for hydrostatic testing with water at 150% of rated pressure. Surge pressure Maximum allowable surge pressure is max. 150% of rated pressure. Conversions 1 psi 1 bar 1 MPa 1 inch 1 Btu.in/ft2h°F °C Important notice This product literature and the recommendations for usage it contains are based on test data reasonably believed to be reliable. It is intended that this literature be used by personnel having specialised training in accordance with currently acceptable industry practice and normal operating conditions. Variation in environment, changes in operating procedures, or extrapolation of data may cause unsatisfactory results. We recommend that your engineers verify the suitability of this product for your intended application. Since we have no control over the conditions of service, we expressly disclaim responsibility for the results obtained or for any consequential or incidental damages of any kind incurred. = 6895 Pa = 105Pa = 1 N/mm2 = 0.07031 kg/cm2 = 14.5 psi = 1.02 kg/cm2 = 145 psi = 10.2 kg/cm2 = 25.4 mm = 0.1442 W/mK = 5/9 (°F-32) Group Headquarters Ameron International Corporation - Fiberglass-Composite Pipe Division 9720 Cypresswood Drive, Suite 325 - Houston, Texas 77070 - U.S.A. Phone: +1 832 912 8282 - Fax: +1 832 912 9393 E-mail: marcom@ameronfpd.com Website: http://www.ameron-fpg.com U.S.A. Ameron International Corporation 1004 Ameron Road P.O. Box 878 Burkburnett, Texas 76364 U.S.A. Phone: +1 940 569 1471 Fax: +1 940 569 2764 U.S.A. Centron International, Inc. P.O. Box 490 600 FM 1195 South Mineral Wells - Texas 76068 U.S.A. Phone: +1 940 325 1341 Fax: +1 940 325 9681 E-mail: info@centrongre.com Europe Ameron B.V. Fiberglass-Composite Pipe P.O. Box 6 4190 CA Geldermalsen The Netherlands Phone: +31 345 587 587 Fax: +31 345 587 561 E-mail: info@ameron-fpg.nl © Ameron 2006. FP 918 A 09/06 supersedes FP 918 09/04. Page 28 of 28. Printed in The Netherlands. Asia Ameron (Pte) Ltd. No. 7A, Tuas Avenue 3 Jurong Singapore 639407 Phone: +65 6861 6118 Fax: +65 6862 1302/6861 7834 E-mail: info@ameron.com.sg