A clean, quiet and economical ventilation system at last

advertisement
A clean, quiet and economical
ventilation system at last
DYKA AIR. RevolutionAIR
Our times require a
new look at ventilation ducts
A good indoor climate is of great importance
in the modern home with its high insulation
values. In many cases, mechanical air extraction
and balanced ventilation offer the right solution.
The new Bouwbesluit (Building Decree) 2012
also imposed increasingly stringent requirements
here, particularly as regards noise and energy
consumption. Existing systems usually do
not appear to be in compliance with these
requirements.
2
EXPORT
And that’s not all: research by the RIVM*
In short, there is talk of new regulations for
has revealed that many ventilation systems
systems that are not functioning optimally.
supplied do not meet the performance
This requires a fresh approach to ventilation
requirements included in the specifications.
ducts: they must perform better, while
This may be, for example, because the
remaining affordable and easy to install.
ventilation ducts were seriously damaged
DYKA is happy to rise to this challenge by
during the construction period and are
introducing a solution that is revolutionary
functioning inadequately as a result.
in all respects: DYKA AIR.
This is why it was recently decided that,
in the near future, ventilation systems
must actually comply with the specified
* carried out by BBA:
www.binnenmilieu.nl/v2/bba/?id=141
performance requirements.
EXPORT
3
Innovation based on
experience and the latest
design technology
DYKA has more than 55 years of experience
in watertight and gastight synthetic piping
systems.
We accordingly went in search of the ideal
ventilation duct system armed with this
expertise in piping material, with the demand
from the installation sector and the wishes of
the end user and building manager in mind.
4
EXPORT
DYKA AIR is designed using CFD
techniques. Using this software to very
accurately simulate air flows, we found the
optimal design with minimal air resistance.
The low resistance of synthetic material
and the cleverly designed auxiliary parts
mean resistance is significantly lower than
in existing systems. This also means less
energy is required to transport the same
quantity of air through the system.
The starting point was the development
We were also assisted by the power of
of a complete ventilation duct system for
Computational Fluid Dynamics (CFD)
houses and apartments. This was to be a
software, the same design method as used
system that in the initial construction phase
in Formula 1 to minimise aerodynamic
could be simply applied using common
resistance. The result is unique. DYKA AIR
construction methods such as concrete
is a synthetic ventilation duct system that
hollow-core slabs, wide slabs and tunnel
offers numerous positive properties thanks
building, while resisting the unavoidable
to the material choice and aerodynamic
loads applied in this phase. It is a system
form. There are advantages for the installer,
that universally matches standard
the building manager and the end user.
ventilation components with no technical
flow restrictions.
With the development of DYKA AIR, we
have further developed existing technology
and our knowledge of synthetics.
EXPORT
5
Improvements on all fronts
These range from extra comfort for the end user to lower
management costs for the building owner, and
time and cost savings for the installer and contractor.
DYKA AIR offers numerous advantages.
Aerodynamic
Because, after all, round
forms offer lower air
resistance than angular ones
6
EXPORT
Aerodynamic
Low-maintenance
Comfort
Efficient
Easy assembly
Impact-resistant
Implementation
Modular
Flexible
Sustainable
Proven lower air resistance
Thanks to the CFD design, each element
in the DYKA AIR system
The flowing transition from standpipe to
only has flowing curves
cast ducting, for example, leads to less
and seamless transition
air turbulence with a sophisticated bend.
points. This results in a
This prevents stationary air, so also dirt
considerable reduction of the internal air
accumulation in the system.
resistance compared to existing ventilation
ducts.
EXPORT
7
Low-maintenance
Less noise The new
The sophisticated design
Bouwbesluit (Building
with the round forms,
Decree) requires that each
flowing transitions
installation per occupied
and smooth material surface prevent
zone causes noise of at most 30 dB(A). The
stationary air and the associated dirt
aerodynamic characteristics of DYKA AIR
accumulation. This was demonstrated by
mean an installation noise reduction can be
CFD simulations. The system is accordingly
achieved.
simple to maintain and continues to
perform optimally year in year out. Should
The flowing forms prevent turbulence that
cleaning nevertheless be required, the
causes flow noise.
brush encounters no obstacles in its path.
The curves and seamless transitions result
The flowing curves allow the brush to pass
in less air resistance in the duct. This means
through the whole system without the
less ventilator capacity is needed for the
slightest of problems.
same flow rate. The ventilator runs at a
A big advantage during casting: an
lower speed, resulting in less source noise.
adhered system is (concrete) watertight.
The synthetic material also has
As a result, there is no internal soiling
advantageous acoustic properties.
during construction. DYKA AIR is therefore
supplied clean.
8
EXPORT
EXPORT
9
Time savings No
special tools are needed
for DYKA AIR. A saw,
deburrer, cleaner and
PVC adhesive is enough. Time-consuming
screwing is unnecessary. A dimensionally
Quality DYKA AIR is
stable connection with resistance to tensile
made of impact-resistant
strain is created immediately with parts
PVC-U, a robust and
that slide into each other before gluing.
dimensionally stable
DYKA AIR can be installed or applied
material. This prevents dent and leak
anywhere, also thanks to the modular
damage in the construction phase and
range. It is light in weight and quick and
guarantees that the system retains its
simple to assemble.
specified capacity. Because the ventilation
ducts are 100% watertight, no concrete
Simplicity DYKA AIR
water can penetrate during construction.
is simple to assemble on
The adhesive joints also guarantee the
location with a sleeve/
tensile strength. This results in an airtight
cotter (adhered) joint.
system with a constant joint quality.
The modular range includes all elements
(oval and around) to obtain very diverse
Design convenience DYKA AIR
forms of ventilation ducts. The components
has universal connecting
are clearly identifiable and guarantee
dimensions (Ø125mm)
foolproof  assembly.
and is accordingly suitable
for any customary
Pleasant work The synthetic material
ventilator box and valve. The data for the
is light in weight and
complete modular piping range are also
has no sharp edges. This
included in pioneering calculation and
makes the installer’s work
drawing software for ventilation systems
a pleasure, and soon
such as StabiCAD 8, Nordined and BIM.
shows time savings. The oval material also
This offers maximum freedom during the
offers constructive advantages: the ducts
design process. With the new calculation
take up little space in floors and walls and
module in StabiCAD 8, you can also
make finishing work much easier.
immediately determine the resistances of
your DYKA AIR design.
10
EXPORT
Efficient
Fast, time-saving and
user-friendly assembly
Sustainable
Flexible
DYKA AIR is the only
DYKA disposes of an
company offering
experienced and dense
ventilation duct
logistics network, while
systems awarded the DUBO mark .
offering great freedom in the choice of
This sustainability mark only comes into
form of delivery. This means we can
consideration for the most environmentally
calculate the complete duct design on
friendly product for a specific application.
the basis of your installation drawing and
®
convert it into a detailed working drawing.
Socially responsible
DYKA is ISO 14001 certified and works
on current programmes concentrating on
Here DYKA AIR was assessed for
CO2 reduction. In August 2012, DYKA
17 different (environmental) aspects,
was also awarded the CSR-4 certificate.
varying from contributions to the
There are only seven companies* to have
greenhouse effect to re-use or processing
reached this level in the Netherlands.
of the residual material according to the
This demonstrates how exceptional this
life cycle analysis (LCA) method. DYKA AIR
performance is.
is made of impact-resistant PVC-U.
* dated 1-9-2012
EXPORT
11
A range that offers the right
solution to any requirement
DYKA AIR consists of round and oval pipes and
all necessary connecting and auxiliary parts.
Thanks to its unique form, the system is highly
suitable for casting in concrete and can be used
in the usual building types.
Oval duct and auxiliary parts
When a multiple of floors is connected
Dimensions: w x h = 195 x 80
to a standpipe, a connection can
be made to the oval cast
Auxiliary parts
ducting using a 125
• Bends 45 ° omnidirectional sleeve and
mm T-piece and 125
sleeve/cotter.
mm oval reducer.
• Bends 90 ° omnidirectional sleeve.
• T-piece 90° omnidirectional sleeve.
Round range:
Pipe Ø80mm and
Transition pieces
Ø125mm.
oval – round
Bends and T-pieces in 45
Here connections are possible to Ø80 and
° and 90 °, omnidirectional sleeve and
Ø125 mm, both in the horizontal and
sleeve/cotter.
vertical direction.
The Ø80 mm oval T-piece can be used to
make a side connection to a maximum of
75 m3/h. Special vaulting ensures the calm
entry of the side flow. This keeps resistance
over the auxiliary piece to a minimum.
12
EXPORT
EXPORT
13
14
EXPORT
The quiet revolution with
convincing arguments
DYKA AIR stands for the quiet revolution
with low maintenance, this comprises
in ventilation ducts. The system ensures
a convincing argument for any building
unique performance in the field of air
manager.
resistance. It accordingly offers advantages
as regards noise, energy consumption and
maintenance. The modular construction
with its unique forms and the easily
useable components guarantee worksaving assembly and finishing work. The
installer and contractor both save time.
Finally, it is important that the system does
not lose any capacity during construction
or during its standing time. In combination
EXPORT
15
DYKA AIR20141009
Aerodynamic
Low-maintenance
Comfort
Efficient
Easy assembly
Impact-resistant
Implementation
Modular
Flexible
Sustainable
DYKA, member of TESSENDERLO GROUP
DYKA B.V., Deccaweg 25, 1042 AE AMSTERDAM, The Netherlands
Tel.: +31(0)20-50 600 80, Fax: +31(0)20-613 56 46, E-mail: dyka.export@dyka.com, Internet: www.dyka.com
Download