COOPER LIGHTING - METALUX DESCRIPTION The VT3 Series is a contem porary looking energy efficient industrial Vaportite fixture that features rugged and durable construction. The VT3 incorporates a full m etal clear tray inside a reinforced fiberglass housing w ith a high im pact diffuser. This Vaportite series is suitable for interior and exterior applications and can be surface or chain m ounted. ® Type Catalog # Project Date Comments The VT3 Series has been designed for m axim um operation in com m ercial institutional and industrial environm ents w here w eathering, high tem perature, hum idity and dust or corrosive fum es are present. Prepared by SPECIFICATION FEATURES A ... Const ruct ion B ... Elect rical* C ... Shielding Fiberglass housing is reinforced polyester and self-extinguishing (ASTM -D635-74) plastic of a perm anent pearl gray color. Top of housing has five em bossm ents (2' unit), nine em bossm ents (4' unit) and thirteen em bossm ents (8' unit), providing m ounting flexibility on uneven surfaces. A w atertite hub for 1/2" conduit entry is provided at each end of housing (standard) for continuous feed. Polyurethane gasketing is form ed in the housing providing a continuous seam less seal for the diffuser. Six sturdy cam latches clam p diffuser tightly for a positive seal betw een housing, gasketing and diffuser. Unit has full m etal gear tray secured by internal fasteners and tethers providing m axim um protection and rigidity. Ballasts are CBM /ETL Class "P" certified suitable to 70°F. (Cold tem perature ballasts are available for less than 0°F starting w ith EHT (T5HO only), EB/PLUS and ER/PLUS Ballasts). Rotor lock lam pholders. Electrical com ponents and fixtures are UL/CUL listed for Wet Locations.* * IP65 approved w ith optional IP67 rating (4' only) w ith 8 latches. New contem porary styled lens clear acrylic w /im pact resistant additives and linear prism s. "DR" - Clear low brightness pattern acrylic w ith 15% high im pact additive. "DR-100" - Clear low brightness pattern acrylic w ith 100% high im pact additive. Exam ple: VT3-232DR-100 A B D ... M ount ing V T3 132 232 332 154T5 254T5 Surface m ount fixture using tw o (2) galvanized brackets (included per 4' section). Optional chain m ount is also available. C 4-13/16" [123mm] 4' INDUSTRIAL 1, 2 OR 3 LAM P Vaportite Industrial 6-15/16" [177mm] M OUNTING DATA LAM P CONFIGURATIONS 41-1/2" [1054mm] Optional Back Hub Locations X X 4-13/16" [123mm] 4-13/16" [123mm] 38-3/4" [984mm] 1/4" x 28" Stud (2 Places) X=1-13/32" [36mm] 6-5/8" [168mm] E N E R G Y D ATA Y X=1-13/32" [36mm] Y=2-1/2" [64mm] 6-15/16" [177mm] Input Watts: 6-15/16" [177mm] EB Ballast & STD Lamps 132 (30) 232 (61) 154T5 (54) X X=5-3/8" [137mm] Y=4-3/16" [107mm] Y X 4-13/16" [123mm] 49-13/16" [1265mm] INSTALLATION DATA 254T5 (106) Y X=1-13/32" [36mm] Y=2-1/2" [64mm] Luminaire Efficacy Rating LER = FI-73 Catalog Number: VT3-232DR 6-15/16" [177mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29 Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output factor should be applied as an additional light loss factor component. MOUNTING BRACKETS Furnished Two per 4' Unit Four per 8' Unit OPTIONAL CHAIN HANGING SET (VT2-CHAIN/SET-U) *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Not Suitable for Wet Locations if EL4 Option is added. Consult Pre Sales Technical Support. VT3 Series -15°F (-26°C) 0°F (-18°C) 20°F (-6°C) 33°F (0°C) 50°F (10°C) 0.67 0.97 0.99 Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks VT3-232 – – VT3-254 0.73 0.76 0.86 0.90 0.94 Order Two (2) Kits for each 4' or 8' Fixture VT3-332 – – 0.96 0.98 0.98 VT3-354 0.91 0.93 – – – Specif icat ions and D im ensions subject t o change w it hout not ice. Consult your representative for additional options and finishes. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power ADF071376 04/03/2009 11:00:15 AM V T3 ORDERING INFORM ATION S A M P L E N U M B E R : V T 3 - 2 3 2 D R - U N V- E B 8 1 - W L- U Tandem Blank= 4' Length 8T=8' Length Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120/277 (2) UNC=Universal Voltage 347/480 (6) Series VT3=Vaportite Number of Lamps (3) 1, 2 or 3 Lamps (Not included) GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed(3), (4) Wattage (Length) 32=32W T8 (48") 28T5=28W T5 (48") 54T5=54W T5HO (48") (3) Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive (High Impact) DR-100=100% High Impact Additive (Extreme) NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) Not available when specifying emergencies, voltage must be specific. (3) 3 Lamp 54W T5HO is recommended for ambient temperatures below 102°F (40°C) with EHT2 ballasts, and below 0°F (-18°C) with EHT1 ballast. (4) Emergency option in 3 lamp version must use remote mount test switch. (5) Top Hub required when stem mounting. (6) 2/3 lamp ballast configurations in EB8/PLUS only for T8 UNC versions. (7) Add GT4 to ordering logic for stock items. Example: VT3-232DR-UNV-EB81-WL-GT4-U. See stock guide online for other stock items. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Packaging U=Unit Pack PALC=Job Pack in Carton WL=Wet Label Ballast Type (1), (4) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. (6) High Ballast Factor >1.13. No. of Total Harmonic Distortion < 20% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EBT = T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EHT = T5HO Linear Electronic Start High Ambient. Total Harmonic Distortion < 10% No. of Ballast (3) 1 or 2 Options 8L=8 Latches (IP67 Rating) M4=Miro 4 Interior Reflector RIF1=Radio Interference Suppressor TH=(2) Top Watertite Hubs only, no End Hubs (5) TEH=(2) Top & (2) End (5) Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry) SSL=Stainless Steel Latches VRS=Vandal Resistant Screws for Latches GT4=Mounting holes provided on geartray for M4 reflector on stock products (7) Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks. Order Two (2) Kits for each 4' or 8' Fixture VT2-SS-MBK=Two (2) Stainless Steel Mounting Brackets. Order Two (2) sets for 8' Fixture. VT3-4FT-M4 PK=4' Specular Interior Reflector Pack for VT3 SHIPPING INFORM ATION Catalog No. Wt. VT3-132 DR-WL VT3-232 DR-WL VT3-154T5 VT3-254T5 16 16 16 16 lbs. lbs. lbs. lbs. PHOTOM ETRICS VT3-232DR-UNVEB81-WL-U (1) Electronic Ballasts (2) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.3 x mounting height, ( ) 1.5 x mounting height Efficiency 77.4% Test Report: LTL10864.IES LER =FL72 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.34 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1103 1097 1083 1059 1025 983 932 870 801 725 640 548 451 352 251 155 77 28 6 45° 1103 1108 1107 1091 1089 1058 1035 991 952 892 831 753 683 611 550 471 367 290 217 Across 1103 1107 1106 1127 1113 1098 1088 1052 1024 971 920 878 814 771 698 592 513 427 342 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 91 78 67 58 51 45 40 36 32 29 26 91 74 61 52 44 38 33 29 25 22 20 91 70 56 46 39 32 28 24 20 17 15 89 79 71 65 59 54 49 45 42 38 36 89 75 65 57 50 44 39 35 31 28 26 89 72 60 51 43 37 32 28 25 22 19 89 69 55 46 38 32 27 23 20 17 15 20% 50% 50 30 10 30% 50 30 10 50 84 71 61 54 48 42 37 33 30 27 24 79 67 58 51 45 40 36 32 29 26 23 75 64 55 49 43 38 34 30 27 25 22 84 68 57 49 42 36 31 27 24 21 19 84 66 53 44 37 31 27 23 20 17 15 79 65 54 47 40 34 30 27 23 20 18 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 899 1512 2847 4169 4413 %Lamp 15.8 26.5 49.9 73.1 77.4 Efficiency 69.7% Test Report: LTL10777.IES LER =FL59 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.05 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1546 1540 1519 1483 1436 1375 1300 1215 1118 1012 896 770 634 496 352 219 113 47 13 45° 1546 1525 1548 1514 1509 1487 1446 1396 1315 1267 1174 1081 954 827 771 704 578 432 285 Across 1546 1533 1525 1546 1566 1530 1509 1502 1425 1384 1308 1179 1107 1101 1044 936 807 614 431 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 91 82 74 67 61 56 51 47 43 40 37 VT3-254T5DR-UNVEHT1-WL-U (1) Electronic Ballasts (2) 54W T5 lamps 4400 lumens Spacing criterion: (II) 1.2 x mounting height, ( ) 1.5 x mounting height Candela %Fixture 20.4 34.3 64.5 94.5 100.0 Average 0-Deg cd/sm 5519 5083 4347 3001 1349 79 63 51 43 36 30 26 23 19 17 15 Average 45-Deg cd/sm 7213 6756 6377 6097 5151 10% 30 10 75 62 52 45 39 33 29 26 23 20 18 0% 0 75 60 49 42 35 30 26 22 19 16 14 73 58 47 40 33 28 24 20 17 15 13 Average 90-Deg cd/sm 7212 7098 7074 6510 6092 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 82 74 66 60 55 50 46 42 39 36 33 82 70 60 52 46 40 36 32 29 26 23 82 66 55 46 40 34 29 26 23 20 18 82 63 50 41 35 29 25 21 18 16 14 80 72 64 58 53 48 44 41 38 35 32 80 68 58 51 45 40 35 32 28 25 23 80 65 54 45 39 33 29 25 22 19 17 80 62 49 41 34 29 24 21 18 15 14 20% 50% 50 30 10 30% 50 30 10 50 76 65 55 49 43 38 34 30 27 24 22 72 61 53 46 41 36 32 29 26 23 21 69 58 50 44 39 34 31 28 25 22 20 76 62 51 44 38 32 28 25 22 19 17 76 59 48 40 33 28 24 21 18 15 13 72 59 49 42 36 31 27 24 21 18 17 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1253 2112 3985 5908 6137 %Lamp 14.2 24.0 45.3 67.1 69.7 %Fixture 20.4 34.4 64.9 96.3 100.0 Average 0-Deg cd/sm 7704 7142 6126 4240 2265 Specif icat ions and D im ensions subject t o change w it hout not ice. Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 72 57 46 39 33 27 24 20 17 15 13 Average 45-Deg cd/sm 10245 9700 8631 9114 7674 10% 30 10 69 57 47 41 35 30 26 23 20 18 16 69 55 45 38 32 27 23 20 17 15 13 0% 0 67 53 43 36 30 25 22 18 16 13 12 Average 90-Deg cd/sm 10279 9531 10102 10293 8760 ADF071376 04/03/2009 11:00:15 AM