COOPER LIGHTING - METALUX ® DESCRIPTION The VT3 Series is a contemporary looking energy efficient industrial Vaportite fixture that features rugged and durable construction. The VT3 incorporates a full metal gear tray inside a reinforced fiberglass housing with a high impact diffuser. This Vaportite series is suitable for interior and exterior applications and can be surface or chain mounted. Type Catalog # Project Date Comments The VT3 Series has been designed for maximum operation in commercial institutional and industrial environments where weathering, high temperature, humidity and dust or corrosive fumes are present. Prepared by SPECIFICATION FEATURES A…Construction B…Electrical* C…Shielding Fiberglass housing is reinforced polyester and self-extinguishing (ASTM-D635-74) plastic of a permanent pearl gray color. Top of housing has five embossments (2' unit), nine embossments (4' unit) and thirteen embossments (8' unit), providing mounting flexibility on uneven surfaces. A watertite hub for 1/2" conduit entry is provided at each end of housing (standard) for continuous feed. Polyurethane gasketing is formed in the housing providing a continuous seamless seal for the diffuser. Six sturdy cam latches clamp diffuser tightly for a positive seal between housing, gasketing and diffuser. Unit has full metal gear tray secured by internal fasteners and tethers providing maximum protection and rigidity. Ballasts are CBM/ETL Class “P” certified. (Cold temperature ballasts are available for less than 0°F starting with EHT (T5HO only), EB/PLUS and ER/PLUS ballasts). Rotor lock lampholders. Electrical components and fixture are UL/CUL listed for Wet Locations.** IP65 approved with optional IP67 rating (4' only) with 8 latches. New contemporary styled lens clear acrylic w/impact resistant additives and linear prisms. “DR” - Clear low brightness pattern acrylic with 15% high impact additive. “DR-100” - Clear low brightness pattern acrylic with 100% high impact additive. Example: VT3-232DR-100 A B C VT3 132 232 332 154T5 254T5 354T5 D…Mounting Surface mount fixture using two (2) galvanized brackets (included per 4' section). Optional chain mount hanging set or snap-on brackets are also available. 4-7/8" [123mm] 4' OR 8' INDUSTRIAL 1, 2 OR 3 LAMP Va p o r t i t e I n d u s t r i a l 6-15/16" [177mm] LAMP CONFIGURATIONS MOUNTING DATA 2 LAMP 1 LAMP 41-1/2" [1054mm] Optional Back Hub Locations 4 FOOT X X 4-7/8" [123mm] 4-7/8" [123mm] X=1-13/32" [36mm] 6-15/16" [177mm] 3 LAMP X=1-13/32" [36mm] Y=2-1/2" [64mm] ENERGY DATA 38-3/4" [984mm] 1/4" x 28" Stud (2 Places) Input Watts: 6-5/8" [168mm] Y 6-15/16" [177mm] X=5-3/8" [137mm] X 49-13/16" [1265mm] 4-3/16" [106mm] Luminaire Efficacy Rating LER = FL-73 Catalog Number: VT3-232DR X 4-7/8" [123mm] X=1-13/32" [36mm] Y=2-1/2" [64mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29 Y 6-15/16" [177mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. INSTALLATION DATA **Not Suitable for Wet Locations if EL4 Option is added. Consult Pre Sales Technical Support. Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output factor should be applied as an additional light loss factor component. MOUNTING BRACKETS Furnished Two per 4' Unit Four per 8' Unit OPTIONAL CHAIN HANGING SET (VT2-CHAIN/SET-U) Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks Order Two (2) Kits for each 8' Fixture COOPER LIGHTING EB Ballast & STD Lamps 132 (30), 232 (61), 332 (80) 154T5 (54), 254T5 (106), 354T5 (185) VT3 Series 20°F (-6°C) 33°F (0°C) VT3-232 -15°F (-26°C) 0°F (-18°C) n/a n/a 0.67 0.97 0.99 VT3-254 0.73 0.76 0.86 0.90 0.94 LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 50°F (10°C) VT3-332 n/a n/a 0.96 0.98 0.98 VT3-354 0.91 0.93 n/a n/a n/a Safe and convenient means of disconnecting power. ADF071376 VT3 PHOTOMETRICS VT3-232DR-UNVEB81-WL-U (1) Electronic Ballasts (2) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 77.4% Test Report: LTL10864.IES LER =FL72 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.34 VT3-254T5DR-UNV- C a n d e l a EHT1-WL-U (1) Electronic Ballasts Angle Along II ⊥ 1546 (2) 54W T5 lamps 0 1540 4400 lumens 5 1519 10 1483 Spacing criterion: 15 1436 (II) 1.2 x mounting 20 1375 height, (⊥) 1.5 x 25 1300 mounting height 30 1215 35 1118 Efficiency 69.7% 40 1012 Test Report: 45 896 50 770 LTL10777.IES 55 634 LER =FL59 60 496 352 Yearly Cost of 1000 65 70 219 lumens, 3000 hrs 75 113 at .08 KWH = $4.05 80 47 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1103 1097 1083 1059 1025 983 932 870 801 725 640 548 451 352 251 155 77 28 6 Across ⊥ 1103 1107 1106 1127 1113 1098 1088 1052 1024 971 920 878 814 771 698 592 513 427 342 45° 1103 1108 1107 1091 1089 1058 1035 991 952 892 831 753 683 611 550 471 367 290 217 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 91 82 74 67 61 56 51 47 43 40 37 91 78 67 58 51 45 40 36 32 29 26 91 74 61 52 44 38 33 29 25 22 20 91 70 56 46 39 32 28 24 20 17 15 89 79 71 65 59 54 49 45 42 38 36 89 75 65 57 50 44 39 35 31 28 26 89 72 60 51 43 37 32 28 25 22 19 89 69 55 46 38 32 27 23 20 17 15 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 899 1512 2847 4169 4413 %Lamp 15.8 26.5 49.9 73.1 77.4 85 90 Coefficients of Utilization %Fixture 20.4 34.3 64.5 94.5 100.0 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 84 71 61 54 48 42 37 33 30 27 24 79 67 58 51 45 40 36 32 29 26 23 75 64 55 49 43 38 34 30 27 25 22 73 58 47 40 33 28 24 20 17 15 13 84 68 57 49 42 36 31 27 24 21 19 84 66 53 44 37 31 27 23 20 17 15 79 65 54 47 40 34 30 27 23 20 18 79 63 51 43 36 30 26 23 19 17 15 75 62 52 45 39 33 29 26 23 20 18 75 60 49 42 35 30 26 22 19 16 14 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Luminance Data Angle in Deg 45 55 65 75 85 Average 0-Deg cd/sm 5519 5083 4347 3001 1349 Average 45-Deg cd/sm 7213 6756 6377 6097 5151 Average 90-Deg cd/sm 7212 7098 7074 6510 6092 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 82 74 66 60 55 50 46 42 39 36 33 82 70 60 52 46 40 36 32 29 26 23 82 66 55 46 40 34 29 26 23 20 18 82 63 50 41 35 29 25 21 18 16 14 80 72 64 58 53 48 44 41 38 35 32 80 68 58 51 45 40 35 32 28 25 23 80 65 54 45 39 33 29 25 22 19 17 80 62 49 41 34 29 24 21 18 15 14 13 50% 50 30 10 30% 50 30 10 50 76 65 55 49 43 38 34 30 27 24 22 72 61 53 46 41 36 32 29 26 23 21 69 58 50 44 39 34 31 28 25 22 20 76 62 51 44 38 32 28 25 22 19 17 76 59 48 40 33 28 24 21 18 15 13 72 59 49 42 36 31 27 24 21 18 17 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp 14.2 24.0 45.3 67.1 69.7 %Fixture 20.4 34.4 64.9 96.3 100.0 Across 1546 1533 1525 1546 1566 1530 1509 1502 1425 1384 1308 1179 1107 1101 1044 936 807 614 431 20% Zonal Lumen Summary Lumens 1253 2112 3985 5908 6137 45° 1546 1525 1548 1514 1509 1487 1446 1396 1315 1267 1174 1081 954 827 771 704 578 432 285 Average 0-Deg cd/sm 7704 7142 6126 4240 2265 72 57 46 39 33 27 24 20 17 15 13 10% 30 10 69 57 47 41 35 30 26 23 20 18 16 Average 45-Deg cd/sm 10245 9700 8631 9114 7674 69 55 45 38 32 27 23 20 17 15 13 0% 0 67 53 43 36 30 25 22 18 16 13 12 Average 90-Deg cd/sm 10279 9531 10102 10293 8760 ORDERING INFORMATION SAMPLE NUMBER: VT3-232DR-UNV-EB81-WL-U Tandem Blank= 4' Length 8T=8' Length Series VT3=Vaportite (Gasketed Enclosure) Number of Lamps (3) 1=1 Lamp 2=2 Lamps 3=3 Lamps (Lamps not included) Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120/277 (2) UNC=Universal Voltage 347/480 (6) GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (4) Wattage (Length) 32=32W T8 (48") 28T5=28W T5 (48") 54T5=54W T5HO (48") (3) Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive DR-100=100% High Impact Additive (Extreme) NOTES: (1) Ballast type used only if ballast & voltage is chosen. (2) Not available when specifying emergency ballasts, voltage must be specific. (3) EHT2 ballasts are recommended for ambient temperatures above 102°F (40°C) 3 Lamp 54W T5HO configurations. (4) Test switch mounted inside luminaire for all lamp types. (5) Top Hub required when stem mounting. (6) 2/3 lamp ballast configurations in EB8/PLUS only for T8 UNC version. (7) Use EHT1 ballast in ambient temperatures below 0°F (-18°C) on 3 Lamp 54W T5HO configurations. (8) Example: VT3-232DR-UNV-EB81-WL-GT4-U. See stock guide online for stock items. (9) Order one (1) kit for 4ft. fixture, or two (2) kits for 8ft. fixture. Ballast Type (1) EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. (6) Total Harmonic Distortion < 10%. High Ballast Factor > 1.13. ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% ER8 /PLUS= T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. EBT =T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor=1.0 EHT = T5HO Linear Electronic (3), (7) Start High Ambient. Total Harmonic Distortion < 10% Number of Ballasts 1=1 Ballast 2=2 Ballasts SHIPPING INFORMATION Catalog No. VT3-132 DR-WL VT3-232 DR-WL VT3-154T5 VT3-254T5 Packaging U=Unit Pack PALC=Job Pack in Carton WL=Wet Location Label Options 8L=8 Latches (IP67 Rating), (4' only) RIF1=Radio Interference Suppressor TH=(2) Top Watertite Hubs (5) TEH=(2) Top & (2) End Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry) (5) BKS=(2) Snap-on Brackets for Chain or Surface Mount M4=Specular Reflector SSL=Stainless Steel Latches VRS=Vandal Resistant Screws for Latches GT4=Stock product only (8) Accessories (order separately) VT2 Stem Bushing=1/2" – 3/8" (Required when using Stem/Sets, Requires (1) per (Stem/Set) VT2-Chain/Set-U=Chain Hanging Set Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks. (9) VT2-SS-MBK=Stainless Steel Mounting Brackets. (9) VT3-BKS2-PK=(2) Snap-on Brackets for Surface or Chain Mount. Adjustable along length of fixture. VT3-4FT-M4 PK=4' Specular Interior Reflector Pack for VT3 (stock product) Wt. 16 16 16 16 lbs. lbs. lbs. lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 11/11 ADF071376