Click on Series name for product info on aimtec.com Series AME3-CJZ 3 Watt | AC-DC / DC-DC Converter FEATURES: Class II Power supply Low no load consumption ≤ 0.3W Continuous Short Circuit Protection I/O Isolation 3000VAC Operating Temp: -25°C to +70°C Input: 85-264VAC, 47-63Hz, or 100-370 VDC Over current and Over voltage Protection Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) Efficiency (%) 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 85-264/47-63 100-370 100-370 100-370 100-370 100-370 100-370 -25 to +70 -25 to +70 -25 to +70 -25 to +70 -25 to +70 -25 to +70 3.3 5 9 12 15 24 700 600 330 250 200 125 6000 6000 1500 1500 1000 330 66 74 75 77 77 78 AME3-3.3SCJZ AME3-5SCJZ AME3-9SCJZ AME3-12SCJZ AME3-15SCJZ AME3-24SCJZ Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current External fuse Output Specifications Parameters Voltage accuracy Line regulation Load regulation Minimum load Ripple & Noise Hold up time Isolation Specifications Parameters Tested I/O voltage Isolation Resistance General Specifications Parameters Switching frequency Over Current protection Over Voltage protection Short circuit protection Operating temperature Storage temperature Temperature coefficient Maximum Case temperature Humidity Case material www.aimtec.com F 052e R8.A Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 230VAC/50Hz, rms Recommended slow blow type 65 30 10 20 0.1 1 Conditions Typical 3.3V output Others LL-HL, Full Load 10% - 100% load, nominal input ±3 ±2 ±0.5 ±1 10 50 50 20MHz bandwidth, 115/230VAC, Full Load 230VAC Conditions Maximum Typical 60 sec Typical Maximum 100 Tel: +1 514 620 2722 1 of 3 % % % mV p-p ms Units 3000 VAC MΩ Maximum Units KHz % of Iout Auto recovery, Continuous -25 to +70 -25 to +105 ±0.02 Non condensing Plastic resin (flammability to UL 94V-0) Units Rated 7.5 12 20 30 With derating above 55°C Units % 115 ≥110 Auto recovery 3.3/5V output 9V output 12/15V output 24V output VAC mA mA A A mA A >1000 Conditions 230 95 95 VDC °C °C %/°C °C % RH Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-CJZ 3 Watt | AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Weight Cooling Dimensions (L x W x H) MTBF Typical Maximum 25 Free air convection 1.46 x 0.96 x 0.71 (37.00 x 24.50 x 18.00mm) > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load Units g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Standards cULus, CE Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity(1KV) RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity IEC/EN/UL 60950-1 EN55022, class A IEC 61000-4-2, Contact:±6KV/Air:±8KV, Criteria B IEC 61000-4-3, 10V/m, Criteria A IEC 61000-4-4, ±2KV, Criteria B, with application circuit IEC 61000-4-5, ±1KV/±2KV, Criteria B, with application circuit IEC 61000-4-6, 10Vrms, Criteria A IEC 61000-4-8, 10A/m, Criteria A IEC 61000-4-11, 0-70%, Criteria B Pin Out Specifications Pin Single AC Input (L) AC Input (N) NC -V Output +V Output 37.00 (1.46) 30.48 (1.20) 0.60 (0.02) 1 24.50 (0.97) 1 3 13 14 16 Dimensions 3 13 17.78 (0.70) Approvals Bottom View 16 14 5.08 (0.20) 4.10 (0.16) 18.00 (0.71) Printed Face www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 2 of 3 All dimensions are typical: millimeters (inches) Pin Diameter: 0.60 ± 0.10 (0.02 ± 0.004) Pin Pitch Tolerance: ± 0.35 (±0.014) Case Tolerance: ± 0.5 (±0.02) Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME3-CJZ 3 Watt | AC-DC / DC-DC Converter Derating Free Air Convection at 25°C Free Air Convection 100 80 Output Power (%) Output power (%) 100 Safe Operating Area 70 Input 100-240VAC or 120-340VDC 60 40 20 80 75 Safe Operating Area 60 50 40 20 0 0 - 25 -20 0 20 55 40 60 70 80 85 100 (100) (120) 100 Ambient Temperature º C 240 (340) 264 (370) Input Voltage VAC (VDC) Application circuit Single Output FUSE 1A/250V 4 AC L AC L MOV S14K350 AC AC N + DC AC N + Vout TVS C1 C2 1µF/50V 3 ‐ Vout *GND connection not allowed Class B compliance recommended circuit FUSE 1A/250V LDM 4.7µH/2A Single Output LCM 10‐30mH AC N AC L MOV S14K350 CX 0.1µF/ 275VAC AC N CY1 1nF/ 400VAC CY2 1nF/ 400VAC AC AC L +Vout +Vout DC ‐ Vout C2 + C1 1µF/50V TVS ‐ Vout GND Model 3.3 & 5 Vout 9Vout 12 & 15 Vout 24 Vout C2 150 µF / 35V 120 µF / 35V 120 µF / 35V 68 µF / 35V TVS 7V 12V 20V 30V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only