Series AME60-MJZ

advertisement
Click on Series name for product info on aimtec.com
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
FEATURES:








I/O Isolation 4000VAC
Input under-voltage protection
Input: 90-264VAC/47-63Hz, or 122-370VDC
Over current, Over Voltage Protection
Continuous Short circuit protection
Low no load consumption ≤0.5W
Efficiency up to 86%
Output Voltage adjustment
Models
Single output
Model
Input Voltage
(VAC/Hz)
Input Voltage
(VDC)
Output
Voltage
(V)
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
90-264/47-63
122-370
122-370
122-370
122-370
122-370
122-370
5
9
12
15
24
48
AME60-5SMJZ
AME60-9SMJZ
AME60-12SMJZ
AME60-15SMJZ
AME60-24SMJZ
AME60-48SMJZ
Output
Current max
(A)
Maximum
capacitive
Load
(µF)
Efficiency
230VAC
(%)
80,000
28,000
14,000
12,000
4000
1000
82
84
86
86
86
86
10
6.6
5
4
2.5
1.25
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Under voltage protection
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC


30
50
Maximum
1.4
0.7
A
A
A
A
VAC
VDC
75
105
Shutdown
Units
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time
Voltage adjustment range
Conditions
Typical
Full load
LL-HL, Full Load
5-100% load
20MHz bandwidth
115VAC
230VAC
Single output only
±2
±0.5
±1
Maximum
Units
150
±10
%
%
%
mV p-p
ms
ms
% of Vout
Rated
Units
4000
1500
500
VAC
VAC
VAC
15
80
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation voltage Input to Ground
Isolation voltage Output to Ground
Typical
60 sec
60 sec
60 sec
General Specifications
Parameters
Switching frequency
Protection class
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum Case temperature
Temperature coefficient
Cooling
www.aimtec.com
F 052e R8.A
Conditions
Typical
100% load
100
Class I
≥110
Zener diode clamp
Continuous, Auto recovery
-40 to +70
-40 to +85
See derating curve
Maximum
KHz
% of Iout
oC
oC
100
±0.02
Units
oC
% / oC
Free air convection
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
310
g
Dimensions (L x W x H)
4.29 x 2.3 x 1.18 inches 109.0 x 58.5 x 30.0 mm
MTBF
> 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
cULus, CE
Information technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC/EN/UL 60950-1
EN55022, class B
IEC 61000-4-2 Level 3
IEC 61000-4-3 Level 3
IEC 61000-4-4 Level 4
IEC 61000-4-5 Level 3
IEC 61000-4-6 Level 3
IEC 61000-4-8 Level 3
IEC 61000-4-11 Class 2
Dimensions
109.00
(4.29)
2
1
BOTTOM
VIEW
15.60
(0.61)
Ø1.80
(0.07)
4xM3
3.00(0.12)
6
5
4
1
2
5.08
(0.20)
Ø1.20
(0.05)
Ø 2.3 (Ø 0.09)
30.70
(1.21)
10.16 19.05
(0.40) (0.75)
58.50 46.30
(2.30) (1.82)
3
8.90
(0.35)
97.30
(3.83)
TOP VIEW
4
5
6
3
Ø 2.3 (Ø 0.09)
Ø 2.3 (Ø 0.09)
Ø 1.7 (Ø 0.07)
96.32
(3.79)
Ø 1.7 (Ø 0.07)
Ø 3.5 (Ø 0.14)
30.00
(1.18)
4.50
(1.18)
6.00
(0.24)
6.00
(0.24)
ᴓ4.50(0.18)
4xM3
3.00(0.12)
Ø 2.3 (Ø 0.09)
DIV: 5.08 (0.2)
Dimensions: mm (inch)
Case Tolerance: ±0.50 (0.02)
Pin Tolerance: ± 1.50 (0.06)
Pin diameter Tolerance: ±0.10 (0.004)
Pin 1, 2, 4 & 5 diameter: 1.80 (0.07)
Pin 3 & 6 diameter: 1.20 (0.047)
Pin Out Specifications
Pin
Single
1
2
3
4
5
6
AC Input (N)
AC Input (L)
Ground
+V Output
-V Output
Trim
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
Deratings
AME60-5SMJZ & AME60-5SMJZ
AME60-12SMJZ & AME60-15SMJZ
Free Air Convection
Free Air Convection
100
Safe Operating Area
100% load
110-264VAC
130-370VDC
80
60
Output Power (%)
Output Power (%)
100
40
25
20
Safe Operating Area
100% load
110-264VAC
130-370VDC
80
60
50
40
20
0
-30
- 40 -20
0
20
45
40
60
70 80
0
-30
- 40 -20
100
Ambient Temperature º C
0
20
40
50
60
70 80
100
Ambient Temperature º C
AME60-24SMJZ & AME60-48SMJZ
Free Air Convection at 25°C
Free Air Convection
100
80
60
Output Power (%)
Output Power (%)
100
Safe Operating Area
100% load
110-264VAC
130-370VDC
45
40
20
80
Safe Operating Area
60
40
20
0
-30
- 40 -20
0
20
40
55
60
70 80
0
90
110
(122) (130)
100
Ambient Temperature º C
264
(370)
Input Voltage VAC (VDC)
Typical application circuits
FUSE
3.15A/300V
Single Output
NTC
MOV
S14K350
AC N
+ Vout
AC L
AC L
AC
DC
AC N
Earth/GND
www.aimtec.com
F 052e R8.A
‐ Vout
Tel: +1 514 620 2722
3 of 5
+ Vout
+
TVS
C1 C2
1µF/50V
‐ Vout
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
Model
Single 5 Vout
Single 9 Vout
Single 12 & 15 Vout
Single 24 Vout
Single 48 Vout
C2
680 µF
470 µF
330 µF
200 µF
100 µF
TVS
7V
12V
20V
30V
64V
Trimming
Output voltage can be externally trimmed by utilizing the methods as shown below
Fixed Resistor
Variable Potentiometer
Leave open if not used.
AME60‐5SMJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) 1 4.95 160.7 2 4.9 78.2 3 4.85 50.7 4
4.8
36.95
5
4.75
28.7
6
4.7
23.2
7
4.65
19.271
8 4.6 16.325 9
4.55
14.033
10
4.5
12.2
1 5.05 164 2 5.1 81.5 3 5.15 54 4
5.2
40.25
5
5.25
32
6
5.3
26.5
7
5.35
22.571
8 5.4 19.625 9
5.45
17.333
10
5.5
15.5
2 8.82 141.96 2 9.18 3 8.73 97.332 3 9.27 4
8.64
73.419
4
9.36
5
8.55
58.515
5
9.45
6
8.46
48.336
6
9.54
7
8.37
40.943
7
9.63
8 8.28 35.329 8 9.72 9
8.19
30.921
9
9.81
10
8.1
27.369
10
9.9
76.19 47.509 34.368
26.829
21.939
18.511
15.974 14.021
12.471
AME60‐9SMJZ Trim down % 1 Vout (VDC) 8.91 Rt down (KΩ) 254.795 Trim up % 1 Vout (VDC) 9.09 Rt up (KΩ) www.aimtec.com
F 052e R8.A
187.839 Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AME60-MJZ
60 Watt | AC-DC / DC-DC Converter
AME60‐12SMJZ Trim down % 1 Vout (VDC) 11.88 Rt down (KΩ) 183.233 Trim up % 1 Vout (VDC) 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4
11.52
61.246
4
12.48
5
11.4
49.499
5
12.6
6
11.28
41.299
6
12.72
7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9
10.92
26.921
9
13.08
10
10.8
23.933
10
13.2
57.03 32.596 22.642
17.238
13.845
11.516 9.819 8.527
7.511
2 3 14.7 14.55 304 199.833 2 3 15.3 15.45 4
14.4
147.75
4
15.6
5
14.25
116.5
5
15.75
6
14.1
95.667
6
15.9
7 13.95 80.786 7 16.05 8 13.8 69.625 8 16.2 9
13.65
60.944
9
16.35
10
13.5
54
10
16.5
30.25
24
19.833
16.857 14.625 12.889
11.5
1 2 3 4
5
6
Vout (VDC) 23.76 23.52 23.28 23.04
22.8
22.56
Rt down (KΩ) 471.081 287.942 205.845 159.249 129.221 108.258
Trim up % 1 2 3 4
5
6
Vout (VDC) 24.24 24.48 24.72 24.96
25.2
25.44
7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9
21.84
71.504
9
26.16
10
21.6
63.865
10
26.4
13.15 11.232 9.771
8.622
Rt up (KΩ) 211.778 AME60‐15SMJZ Trim down % 1 14.85 616.5 1 15.15 Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) 124 AME60‐24SMJZ 61.5 40.667 Trim down % Rt up (KΩ) 239.556 64.606 36.982 25.728
19.619
15.783
AME60‐48SMJZ Trim down % 1 2 3
4
5
6
7 8 9
10
Vout (VDC) 47.52 47.04 46.56
46.08
45.6
45.12
44.64 44.16 43.68
43.2
Rt down (KΩ) 1825.631 1135.459 818.914 637.228 519.354 436.695 375.522 328.42 291.036 260.643
Trim up % 1 2 3
4
5
6
7 8 9
10
Vout (VDC) 48.48 48.96 49.44
49.92
50.4
50.88
51.36 51.84 52.32
52.8
Rt up (KΩ) 561.5 130.649 73.548 50.996 38.919 31.395 26.258 22.527 19.694
17.47
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)