Click on Series name for product info on aimtec.com Series AME60-MJZ 60 Watt | AC-DC / DC-DC Converter FEATURES: I/O Isolation 4000VAC Input under-voltage protection Input: 90-264VAC/47-63Hz, or 122-370VDC Over current, Over Voltage Protection Continuous Short circuit protection Low no load consumption ≤0.5W Efficiency up to 86% Output Voltage adjustment Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) 90-264/47-63 90-264/47-63 90-264/47-63 90-264/47-63 90-264/47-63 90-264/47-63 122-370 122-370 122-370 122-370 122-370 122-370 5 9 12 15 24 48 AME60-5SMJZ AME60-9SMJZ AME60-12SMJZ AME60-15SMJZ AME60-24SMJZ AME60-48SMJZ Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) 80,000 28,000 14,000 12,000 4000 1000 82 84 86 86 86 86 10 6.6 5 4 2.5 1.25 Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Under voltage protection Conditions Typical 115 VAC 230 VAC 115 VAC 230 VAC 30 50 Maximum 1.4 0.7 A A A A VAC VDC 75 105 Shutdown Units Output Specifications Parameters Voltage accuracy Line regulation Load regulation Ripple & Noise Hold-up time Voltage adjustment range Conditions Typical Full load LL-HL, Full Load 5-100% load 20MHz bandwidth 115VAC 230VAC Single output only ±2 ±0.5 ±1 Maximum Units 150 ±10 % % % mV p-p ms ms % of Vout Rated Units 4000 1500 500 VAC VAC VAC 15 80 Isolation Specifications Parameters Conditions Tested I/O voltage Isolation voltage Input to Ground Isolation voltage Output to Ground Typical 60 sec 60 sec 60 sec General Specifications Parameters Switching frequency Protection class Over current protection Over voltage protection Short circuit protection Operating temperature Storage temperature Maximum Case temperature Temperature coefficient Cooling www.aimtec.com F 052e R8.A Conditions Typical 100% load 100 Class I ≥110 Zener diode clamp Continuous, Auto recovery -40 to +70 -40 to +85 See derating curve Maximum KHz % of Iout oC oC 100 ±0.02 Units oC % / oC Free air convection Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME60-MJZ 60 Watt | AC-DC / DC-DC Converter General Specifications (continued) Parameters Conditions Typical Maximum Units Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 310 g Dimensions (L x W x H) 4.29 x 2.3 x 1.18 inches 109.0 x 58.5 x 30.0 mm MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals cULus, CE Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Standards IEC/EN/UL 60950-1 EN55022, class B IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 3 IEC 61000-4-4 Level 4 IEC 61000-4-5 Level 3 IEC 61000-4-6 Level 3 IEC 61000-4-8 Level 3 IEC 61000-4-11 Class 2 Dimensions 109.00 (4.29) 2 1 BOTTOM VIEW 15.60 (0.61) Ø1.80 (0.07) 4xM3 3.00(0.12) 6 5 4 1 2 5.08 (0.20) Ø1.20 (0.05) Ø 2.3 (Ø 0.09) 30.70 (1.21) 10.16 19.05 (0.40) (0.75) 58.50 46.30 (2.30) (1.82) 3 8.90 (0.35) 97.30 (3.83) TOP VIEW 4 5 6 3 Ø 2.3 (Ø 0.09) Ø 2.3 (Ø 0.09) Ø 1.7 (Ø 0.07) 96.32 (3.79) Ø 1.7 (Ø 0.07) Ø 3.5 (Ø 0.14) 30.00 (1.18) 4.50 (1.18) 6.00 (0.24) 6.00 (0.24) ᴓ4.50(0.18) 4xM3 3.00(0.12) Ø 2.3 (Ø 0.09) DIV: 5.08 (0.2) Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 4 & 5 diameter: 1.80 (0.07) Pin 3 & 6 diameter: 1.20 (0.047) Pin Out Specifications Pin Single 1 2 3 4 5 6 AC Input (N) AC Input (L) Ground +V Output -V Output Trim www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME60-MJZ 60 Watt | AC-DC / DC-DC Converter Deratings AME60-5SMJZ & AME60-5SMJZ AME60-12SMJZ & AME60-15SMJZ Free Air Convection Free Air Convection 100 Safe Operating Area 100% load 110-264VAC 130-370VDC 80 60 Output Power (%) Output Power (%) 100 40 25 20 Safe Operating Area 100% load 110-264VAC 130-370VDC 80 60 50 40 20 0 -30 - 40 -20 0 20 45 40 60 70 80 0 -30 - 40 -20 100 Ambient Temperature º C 0 20 40 50 60 70 80 100 Ambient Temperature º C AME60-24SMJZ & AME60-48SMJZ Free Air Convection at 25°C Free Air Convection 100 80 60 Output Power (%) Output Power (%) 100 Safe Operating Area 100% load 110-264VAC 130-370VDC 45 40 20 80 Safe Operating Area 60 40 20 0 -30 - 40 -20 0 20 40 55 60 70 80 0 90 110 (122) (130) 100 Ambient Temperature º C 264 (370) Input Voltage VAC (VDC) Typical application circuits FUSE 3.15A/300V Single Output NTC MOV S14K350 AC N + Vout AC L AC L AC DC AC N Earth/GND www.aimtec.com F 052e R8.A ‐ Vout Tel: +1 514 620 2722 3 of 5 + Vout + TVS C1 C2 1µF/50V ‐ Vout Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME60-MJZ 60 Watt | AC-DC / DC-DC Converter Model Single 5 Vout Single 9 Vout Single 12 & 15 Vout Single 24 Vout Single 48 Vout C2 680 µF 470 µF 330 µF 200 µF 100 µF TVS 7V 12V 20V 30V 64V Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME60‐5SMJZ Trim down % Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) 1 4.95 160.7 2 4.9 78.2 3 4.85 50.7 4 4.8 36.95 5 4.75 28.7 6 4.7 23.2 7 4.65 19.271 8 4.6 16.325 9 4.55 14.033 10 4.5 12.2 1 5.05 164 2 5.1 81.5 3 5.15 54 4 5.2 40.25 5 5.25 32 6 5.3 26.5 7 5.35 22.571 8 5.4 19.625 9 5.45 17.333 10 5.5 15.5 2 8.82 141.96 2 9.18 3 8.73 97.332 3 9.27 4 8.64 73.419 4 9.36 5 8.55 58.515 5 9.45 6 8.46 48.336 6 9.54 7 8.37 40.943 7 9.63 8 8.28 35.329 8 9.72 9 8.19 30.921 9 9.81 10 8.1 27.369 10 9.9 76.19 47.509 34.368 26.829 21.939 18.511 15.974 14.021 12.471 AME60‐9SMJZ Trim down % 1 Vout (VDC) 8.91 Rt down (KΩ) 254.795 Trim up % 1 Vout (VDC) 9.09 Rt up (KΩ) www.aimtec.com F 052e R8.A 187.839 Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AME60-MJZ 60 Watt | AC-DC / DC-DC Converter AME60‐12SMJZ Trim down % 1 Vout (VDC) 11.88 Rt down (KΩ) 183.233 Trim up % 1 Vout (VDC) 12.12 2 11.76 111.59 2 12.24 3 11.64 79.474 3 12.36 4 11.52 61.246 4 12.48 5 11.4 49.499 5 12.6 6 11.28 41.299 6 12.72 7 11.16 35.249 7 12.84 8 11.04 30.602 8 12.96 9 10.92 26.921 9 13.08 10 10.8 23.933 10 13.2 57.03 32.596 22.642 17.238 13.845 11.516 9.819 8.527 7.511 2 3 14.7 14.55 304 199.833 2 3 15.3 15.45 4 14.4 147.75 4 15.6 5 14.25 116.5 5 15.75 6 14.1 95.667 6 15.9 7 13.95 80.786 7 16.05 8 13.8 69.625 8 16.2 9 13.65 60.944 9 16.35 10 13.5 54 10 16.5 30.25 24 19.833 16.857 14.625 12.889 11.5 1 2 3 4 5 6 Vout (VDC) 23.76 23.52 23.28 23.04 22.8 22.56 Rt down (KΩ) 471.081 287.942 205.845 159.249 129.221 108.258 Trim up % 1 2 3 4 5 6 Vout (VDC) 24.24 24.48 24.72 24.96 25.2 25.44 7 22.32 92.793 7 25.68 8 22.08 80.914 8 25.92 9 21.84 71.504 9 26.16 10 21.6 63.865 10 26.4 13.15 11.232 9.771 8.622 Rt up (KΩ) 211.778 AME60‐15SMJZ Trim down % 1 14.85 616.5 1 15.15 Vout (VDC) Rt down (KΩ) Trim up % Vout (VDC) Rt up (KΩ) 124 AME60‐24SMJZ 61.5 40.667 Trim down % Rt up (KΩ) 239.556 64.606 36.982 25.728 19.619 15.783 AME60‐48SMJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Vout (VDC) 47.52 47.04 46.56 46.08 45.6 45.12 44.64 44.16 43.68 43.2 Rt down (KΩ) 1825.631 1135.459 818.914 637.228 519.354 436.695 375.522 328.42 291.036 260.643 Trim up % 1 2 3 4 5 6 7 8 9 10 Vout (VDC) 48.48 48.96 49.44 49.92 50.4 50.88 51.36 51.84 52.32 52.8 Rt up (KΩ) 561.5 130.649 73.548 50.996 38.919 31.395 26.258 22.527 19.694 17.47 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8.A Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only