Series AME5-JZ

advertisement
Click on Series name for product info on aimtec.com
Series AME5-JZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:




I/O Isolation 3000VAC
Operating Temp: -40°C to +70°C
Over current Protection
Input: 85-305VAC, 47-63Hz, or 100-430VDC




Low Ripple and Noise
Over Voltage Protection
Up to 84% efficiency
Short Circuit Protection
Models
Single output
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Voltage
(V)
Output
Current max
(A)
Maximum
capacitive load
(µF)
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
100-430
100-430
100-430
100-430
100-430
100-430
4
5
5
5
5
5
3.3
5
9
12
15
24
1.25
1
0.55
0.42
0.33
0.23
4000
4000
1800
1800
1500
330
Model
AME5-3.3SJZ
AME5-5SJZ
AME5-9SJZ
AME5-12SJZ
AME5-15SJZ
AME5-24SJZ
Efficiency
(%)
230
VAC
72
77
79
81
82
84
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
Typical
115 VAC
230 VAC
115 VAC
230 VAC
Recommended slow blow type
10
15

1
Conditions
Typical
(LL-HL)
10-100% load
±2
±0.5
±1
115 VAC
230 VAC
15
80
Conditions
Typical
Maximum
Units
125
80
mA
mA
A
A
mA
A
0.25
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Hold-up time
Maximum
Units
%
%
%
mV p-p
ms
ms
100
Isolation Specifications
Parameters
Tested I/O voltage
Input to Output, 60 sec
Input to Ground
Isolation resistance
Rated
Units
3000
2000
VAC
>1000
MΩ
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
www.aimtec.com
F 052e R8.A
Conditions
Typical
Maximum
65
≥110
Over voltage shutdown
Auto recovery
-40 to +70
See derating curve
132
100
-40 to +105
±0.02
Tel: +1 514 620 2722
1 of 3
Units
KHz
% of Iout
°C
°C
°C
% / °C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-JZ
5 Watt | AC-DC / DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Cooling
Free air convection
Humidity
Non condensing
95
% RH
Case material
Plastic (flammability to UL 94V-0)
Weight
75
g
Dimensions (L x W x H)
55.0 x 45.0 x 21.0 mm (2.17 x 1.77 x 0.83 inches)
MTBF
> 300 000 hrs (MIL-HDBK -217F, t=+25oC)/ Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage
(115/230VAC) and at rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency approvals
CE, UL
Information Technology Equipment
EMI - Conducted and radiated emission
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Standards
IEC/EN/UL 60950-1
EN55022, class B
EN55024: 2010
IEC 61000-4-2: Contact ±6KV/Air ±8KV, Criteria B
IEC 61000-4-3: 10V/m, Criteria A
IEC 61000-4-4: ±2KV, Criteria B
IEC 61000-4-5: ±1KV/±2KV, Criteria B
IEC 61000-4-6: 10Vrms, Criteria A
IEC 61000-4-8: 10A/m, Criteria A
IEC 61000-4-11: 0-70%, Criteria B
Typical Application circuit
Single Output
FUSE
3.15A/300V
+ Vout
AC L
AC L
MOV
S14K350
AC
AC N
+ Vout
+
DC
C1 C2
1µF/50V
AC N
‐ Vout
Earth/GND
TVS
‐ Vout
Vout
C2
TVS
3.3 & 5V
9V
12V
15V
24V
330 µF/50V
120 µF/50V
120 µF/50V
68 µF/50V
68 µF/50V
7A
12A
20A
20A
30A
Pin Out Specifications
Pin
Single
1
2
3
4
5
Earth/Ground
AC Input (L)
AC Input (N)
- V output
+ V output
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AME5-JZ
5 Watt | AC-DC / DC-DC Converter
Dimensions
45.00
(1.77)
12.50
(0.49)
2
Bottom
View
14.50
(0.57)
3
1
5
16.00
(0.63)
10.00
(0.39)
55.00
(2.17)
2
4
1
Top View
5
3
40.50
(1.59)
7.25
(0.29)
4
DIV: 10.00 (0.40)
21.00
(0.83)
Ø 1.50 (Ø 0.06)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004)
6.00
(0.24)
1.00
(0.04)
Derating
Free Air Convection
Free Air Convection at 25°C
80
60
100
Output Power (%)
Output Power (%)
100
Safe Operating Area
100% load 100-277VAC
Or 120-390VDC
40
80
75
Safe Operating Area
40
20
20
0
- 40
60
- 20 -10 0
20
40
55
70 80
60
0
85
100
(100) (120)
100
277
(390)
305
(430)
Input Voltage VAC (VDC)
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer
controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary
based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C,
humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all
internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for
release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications
which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available
at www.aimtec.com.
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Download