1-1.0-01.02-E-03/07 DKP - Square diffuser with flat adjustable panel components for air-conditioning systems Diffusers DKP DKP Square diffuser with flat adjustable panel Ve r s i o n s - DKP (square diffuser with flat adjustable panel) The DK series of square diffusers with flat adjustable panels and circular spigots has been designed for the radial diffusion of air from the ceiling in rooms with a height of less than 3 m. The ability to adjust the height of the perimeter gap allows the range of the air to be adjusted following any variations in the air pressure, in this way avoiding annoying turbulence and unexpected downflows of cold air in the room. The adjustment is made by the vertical movement of the lower square plate that is connected to the external housing by means of pins and fixing clips. Quick reference selection table 500x500-250 400x400-200 40 900 1000 30 700 300 90 100 80 70 200 60 50 40 30 90 100 80 70 20 Q [l/s] 60 50 Q [m3/h] 500 NR 20 250x250-100 600 300x300-125 25 50 Pa 800 p 5 10 200 350x350-160 400 BxB - ØN [mm] 600x600-315 Q [m3/h] Q [l/s] Legenda Q [m3/h] or [l/s] supply air flow rate BxB - ØN [mm] Δp [Pa] NR nominal dimensions of the diffuser pressure loss noise rating (ISO standard, in relation to 10-12 W) taking no account of the attenuation of the room w w w. t e c n o v e n t i l . c o m VER. 19/02/07 We reserve the right to make any modifications without prior notice. 1 DKP Diffusers Dimensions Section dimensions ØN-2 10 70 10 20 (B+24)x(H+24) 3D Dimensions Model 250X250 300X300 350X350 400X400 500X500 600X600 ØN (mm) 100 125 160 200 250 315 BxB (mm) 250x250 300x300 350x350 400x400 500x500 600x600 Construction The DKP series of diffusers is made of aluminium (external housing) and steel (adjustable central plate and upper circular collar), painted RAL 9010 white, and available in other colours on request. 2 VER. 19/02/07 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m DKP Diffusers Accessories PS7-PSI7 plenum boxes PS7–Standard plenum box made of sendzimir zinc plated steel with side connection. PSI7-Plenum box insulated with class 1 certified material (Ministerial Decree 26-6-1984 Article 8) made of Sendzimir zinc plated steel with side connection. PS8-PSI8 plenum boxes PS8–Standard plenum box made of Sendzimir zinc plated steel with top connection. PSI8-Plenum box insulated with class 1 certified material (Ministerial Decree 26-6-1984 Article 8) made of Sendzimir zinc plated steel with top connection. Plenum box dimensions Plenum PS7 PS8 Ø (mm) BXH (mm) S (mm) ØC (mm) ØN (mm) Weight (kg) BXH (mm) S (mm) ØC (mm) ØN (mm) Weight (kg) 100 225x225 150 98 102 1,5 225x225 200 98 102 2,5 125 250x250 150 98 127 2 250x250 200 98 127 2,5 160 285x285 175 123 162 2,5 285x285 200 123 162 2,5 200 325x325 210 158 202 3 325x325 200 158 202 3 250 375x375 250 198 252 4,5 375x375 200 198 252 3,5 315 440x440 300 248 317 6 440x440 200 248 317 4,5 w w w. t e c n o v e n t i l . c o m VER. 19/02/07 We reserve the right to make any modifications without prior notice. 3 DKP Diffusers SF – butterfly calibration damper Butterfly calibration damper made of Sendzimir zinc plated steel Technical data Adjustment of the central plate The effective outlet area values S shown on the following page relate to a perimeter gap height d= 10 mm. For other values of d, the value S must be multiplied by an appropriate coefficient, shown in the following table (K= d / 10): d (mm) K 5 0,5 10 1 15 1,5 20 2 d Warning: the effective outlet area of DKPs vary markedly with the height of the plate d. For a given air pressure a diffuser with a larger aperture d may return lower pressure loss and noise level values than one with a nominally greater diameter, as in the following example: DKP400x400 (Ø200) - 300 m3/h - d= 15 mm - Dp= 22 Pa DKP600x600 (Ø315) - 300 m3/h - d= 5 mm - Dp= 90 Pa 4 VER. 19/02/07 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m Diffusers DKP E f f e c t i v e o u t l e t a r e a S ( m 2) a n d w e i g h t s ( k g ) The effective outlet area is a notional area that, once the velocity of the air is known, makes it possible to arrive at the rate of flow that is actually passing through the diffuser. The measurement is carried out with an instrument that measures the velocity of the air at various points across the diffuser. The formula that links the various parameters is as follows: where Q = vK x S x 3600 Q = supply air flow rate [m3/h] vk = average measured velocity [m/s] S = effective outlet area [m2] BxB (mm) 250X250 300X300 350x350 400x400 500x500 600x600 ØN (mm) 100 125 160 200 250 315 S (m ) 0.0069 0.0081 0.0094 0.0106 0.0131 0.0156 Weight (kg) 0,5 0,7 0,9 1,1 1,6 2,2 2 For the variations of effective outlet area S with changes in height d see Page 4 >> 25 0x >> 25 0 30 0x >> 30 35 0 >> 0 x 40 350 0x >> 40 50 0 0x >> 5 00 60 0x 60 0 Pr e s s u r e l o s s a n d n o i s e l e v e l s 0,0 0,0 32 25 0 0,0 9 11 0,0 13 0,0 16 0,0 20 0,0 0,0 07 08 5 0,0 05 0,0 150 0,0 0,0 03 S [m2] 04 5 5 B x B [mm] ρ = 1,2 kg/m3 100 90 80 10 70 9 45 60 8 50 40 7 6 30 35 vK [m/s] ∆p [Pa] 40 5 20 30 NR 4 25 10 9 8 3 7 900 800 700 600 2000 500 400 Legenda 200 500 400 100 300 90 80 70 60 200 50 40 90 100 30 80 60 70 20 Q [l/s] 50 5 Q [m3/h] 300 6 1000 20 Q [m3/h] Q [l/s] Q [m3/h] supply air flow rate BxB [mm] diffuser nominal dimensions S [m2] effective outlet area vk [m/s] velocity relating to the effective outlet area S Δp [Pa] total pressure loss NR NR noise rating (ISO standard, in relation to 10-12 W) taking no account of the attenuation of the room w w w. t e c n o v e n t i l . c o m VER. 19/02/07 We reserve the right to make any modifications without prior notice. 5 DKP Diffusers 03 0,0 5 0 0,0 45 0 0,0 55 0,007 > 0,008 > 2 > 5 0,009 > 30 0 x 0 25 1 > 0,0 1 >> 35 x 3 0 13 > 4 0 x 00 0,0 > 00 35 16 > 5 x 0 4 0,0 >> 00 00 60 x 5 20 0 x 00 0,0 6 25 00 0,0 32 Horizontal throws S [m2] 8 0,0 B x B [mm] 7 6 5 4 3 2 1 5 L0,2 [m] D [m] 4 3 2 1 0,9 0,8 0,7 0,6 -10 °C 3 2,5 2 1,5 1 0,5 1500 700 800 900 1000 600 200 500 400 300 70 80 90 100 60 50 40 200 70 80 90 100 0 60 0,5 50 1 40 1,5 0 30 2 0,5 20 2,5 1 9 10 1,5 30 2 0 °C ρ = 1,2 kg/m3 0,5 400 +10 °C 300 ∆T Q [m3/h] Q [l/s] 0 y [m] Legend Q [m3/h] o [l/s] supply air flow rate BxB [mm] diffuser nominal dimensions S [m2] effective outlet area vm [m/s] average velocity of the throw at distance L L [m] diffusion radius (= x + y) x [m] horizontal dimension of the throw y [m] vertical dimension of the throw L0,2 [m] throw with terminal velocity of 0.2 m/s D [m] distance between two diffusers ΔT [°C] difference between supply air temperature and ambient temperature L D L x vm y y vm vm H 1,80 OCCUPIED ZONE ZONA OCCUPATA The average throw velocity L0.2 at a distance x other than that indicated in the diagrams is obtained by using the following formula:vx = 0.2 x (L0.2 / x) The values shown in the diagram relate to a throw with ceiling influence. For free jet throws, the values relative to the throws are multiplied by a coefficient of 0.7. 6 VER. 19/02/07 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m Diffusers DKP Fixing systems Mounting with self-tapping screws on the diffuser collar suspension to be sospensione a carried out by the cura del cliente client suspension to be sospensione a carried out by the cura client del cliente self-tappingviti autoforanti screws The removal of the lower plate enables the regulating damper to be adjusted from below and for hidden fixing to be carried out. w w w. t e c n o v e n t i l . c o m VER. 19/02/07 We reserve the right to make any modifications without prior notice. 7 DKP 8 Diffusers VER. 19/02/07 We reserve the right to make any modifications without prior notice. w w w. t e c n o v e n t i l . c o m components for air-conditioning systems tecno-ventil s.p.a. Via Parma, 2 2 6 0 1 6 S p i n o d ’A d d a ( C R ) Te l . + 3 9 0 3 7 3 . 9 8 0 4 5 6 Fa x + 3 9 0 3 7 3 . 9 8 0 6 8 1 w w w. t e c n ove n t i l . c o m info@tecnoventil.com