RQ-50 series 50W Quad Output Switching Power Supply MODEL:RQ-50C OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT RIPPLE & NOISE V1: 80 I/P: V1: 18 mVp-p (Max ) mVp-p (Max ) V2: 120 mVp-p (Max ) V3: 100 mVp-p (Max ) V4: 80 2 OUTPUT VOLTAGE 230 VAC O/P:FULL LOAD Ta:25℃ V2: 20 mVp-p (Max ) I/P: VAC 4.48V~ 5.89 V/ 230VAC ADJUST RANGE VAC 4.48V~ 5.89 V/ 115 VAC P V3: 17 mVp-p (Max ) mVp-p (Max ) CH1: 4.75V~ 5.5 V VERDICT V4: 18 mVp-p (Max ) 230 I/P: 115 P O/P:MIN LOAD Ta:25℃ 3 4 5 6 7 OUTPUT VOLTAGE V1: -2 %~ 2 % (Max) I/P: TOLERANCE V2: -6 %~ 6 % (Max) V3: -2 %~2 % (Max ) O/P:FULL/ MIN 40 Ta:25℃ V4: -2 %~ 2 % (Max ) LINE REGULATION LOAD REGULATION CROSS REGULATION SET UP TIME 115 VAC / 264 % LOAD % (Max) I/P: 115 VAC ~ V2: -1.5 %~ 1.5 % (Max) V3: -0.5 %~ 0.5 % (Max ) O/P:FULL LOAD Ta:25℃ V4: -0.5 %~ 0.5 % (Max ) 264 VAC P V1: 0 %~ 0 % V2: 0.8 %~ -0.1 % P V3: 0 %~ 0 % V4: 0.05 %~ -0.05 % % (Max) I/P: 230 V2: -3 %~ 3 % (Max) V3: -1 %~ 1 % (Max ) O/P:FULL ~MIN LOAD Ta:25℃ V4: -1 VAC %~ 1 % (Max ) V1: 0.3 %~ -0.3 % V2: 0.5 %~ -1.2 % P V3: 0.2 %~ -0.2 % V4: 0.2 %~ -0.2 % V1: -0.5 %~ 0.5 % (Max) I/P: 230 V2: -3 %~ 3 % (Max) O/P: Testing O/P 60%LOAD V3: -1 %~ 1 % (Max ) V4: -1 %~ 1 % (Max ) ms (Max) V2: 3.4 %~ -3.4 % V3: 0.2 %~ -0.2 % V1: -0.5 %~ 0.5 115 VAC/ 1200 ms (Max) V1: 0.3 %~ -0.3 % V4: 0.2 %~ -0.2 % V1: -0.5%~ -0.5 230 VAC/ 500 VAC VAC Other O/P 40%LOAD Change Ta:25℃ I/P: 230 I/P: 115 V1: 0 %~ 0 % V2: 2 %~ -2 % V3: 0 %~ 0 % P V4: 0.1 %~ -0.1 % VAC VAC 230 VAC/ 204 ms 115 VAC/ 711 ms P O/P:FULL LOAD Ta:25℃ 8 RISE TIME 230 VAC/ 20 ms (Max) I/P: 230 115 VAC/ 30 ms (Max) I/P: 115 VAC VAC 230 VAC/ 8 ms 115 VAC/ 8 ms P O/P:FULL LOAD Ta:25℃ 9 HOLD UP TIME 230 VAC/ 50 ms(TYP) I/P: 115 VAC/ 10 ms(TYP) I/P: 115 230 VAC 230 VAC/ 70 ms VAC 115 VAC/ 13 ms TEST: <5 % P O/P:FULL LOAD Ta:25℃ 10 OVER/UNDERSHOOT TEST I/P: < +5% 230 VAC O/P:FULL LOAD Ta:25℃ 11 DYNAMIC LOAD V1: 1000 mVp-p I/P: 230 VAC P 143 mVp-p O/P:FULL /Min LOAD P 90%DUTY/1KHZ Ta:25℃ Model:RQ-50C Test Report 1 / 5 RQ-50 series 50W Quad Output Switching Power Supply INPUT FUNCTION TEST NO 1 TEST ITEM SPECICATION INPUT VOLTAGE RANGE TEST CONDITION 88VAC~ 264 VAC RESULT I/P:TESTING VERDICT 62 V~ 264 V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 85 V HIGH-LINE+15%= 300 P V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE 47 HZ ~ 63 HZ NO DAMAGE OSC 3 VAC ~ 264 VAC TEST: OK O/P:FULL~MIN LOAD Ta:25℃ 75 % (TYP) EFFICIENCY I/P: 88 P I/P: 230 VAC 75.9 % O/P:FULL LOAD Ta:25℃ 4 INPUT CURRENT 230 V/ 0.8 A (TYP) 115 V/ 1.3 A (TYP) P I/P: 230 VAC I = 0.64 A/ 230 VAC I/P: 115 VAC I = 1.1 A/ 115 VAC P O/P:FULL LOAD Ta:25℃ 5 INRUSH CURRENT 230 V/ 36 A(TYP) COLD START 6 LEAKAGE CURRENT < 2 I/P: 230 VAC I = 28 A/ 230 VAC O/P:FULL LOAD Ta:25℃ mA / 240 VAC I/P: 254 P VAC O/P:Min LOAD Ta:25℃ L-FG: 0.7 mA N-FG: 0.7 mA P PROTECTION FUNCTION TEST NO 1 2 TEST ITEM SPECICATION TEST CONDITION RESULT OVER LOAD PROTECTION 110 %~ I/P: 230 VAC 134 %/ 230 VAC I/P: 115 VAC 132 %/ 115 VAC OVER VOLTAGE PROTECTION 150 % CH1: 5.75 V~ 6.75 V O/P:TESTING Ta:25℃ Hiccup Mode I/P: 230 6.24 V/ 230 VAC I/P: 115 3 SHORT PROTECTION VAC VAC VERDICT P 6.24 V/ 115 VAC O/P:MIN LOAD Ta:25℃ Hiccup Model SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P: Full Ta:25℃ LOAD Hiccup Mode P P Model:RQ-50C Test Report 2 / 5 RQ-50 series 50W Quad Output Switching Power Supply ENVIRONMENT TEST NO 1 TEST ITEM SPECICATION TEMPERATURE RISE TEST MODEL: RQ-50C TEST CONDITION 1. ROOM AMBIENT BURN-IN: 1.5 RESULT VERDICT HRS I/P: 230 VAC O/P: FULL LOAD Ta=30.9 ℃ 2. HIGH AMBIENT BURN-IN: 2 HRS I/P: 230 VAC O/P: FULL LOAD Ta= 44.1 NO 2 OVER LOAD BURN-IN TEST Position ℃ ROOM AMBIENT HIGH AMBIENT Ta= 30.9 ℃ Ta= 44.1 ℃ 73.5℃ 79.8℃ P/N 1 LF1 TF-484 LS 2 BD1 D3SB60 4A/600V SHI 82.8℃ 92.8℃ 101.0℃ 3 RG2 7915 1A/12V M 90.3℃ 4 D55 MBR1545CT 15A/45V ON 102.7℃ 113.3℃ 5 C5 100U/400V RUB 105℃ 56.3℃ 68.9℃ 6 T1 COIL TF-1022 LS 84.1℃ 97.6℃ 7 D50 F10SC6 10A/60V SHI 96.7℃ 107.4℃ 8 RG1 7905 1A/5V M 96.4℃ 105.7℃ 9 Q1 K2545 6A/600V TOS 95.1℃ 106.0℃ 10 C10 100U/35V RUB 105℃ YXF 59.2℃ 71.5℃ 100.2℃ 11 D1 EGP20J 2A/600V ZOW 89.5℃ 12 T1 CORE TF-1022 LS 81.5℃ 94.6℃ 13 C63 470U/25V NCC 105℃ KY 85.1℃ 97.4℃ 14 C56 2200U/16V NCC 105℃ KY 82.2℃ 93.9℃ 15 C53 470U/25V NCC 105℃KY 75.5℃ 87.8℃ NO DAMAGE 1 HOUR ( MIN ) I/P: 230 VAC O/P: 128﹪LOAD P TEST: OK P Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/P: 230VAC O/P: 100 ﹪LOAD Ta= 4 I/P: 272 VAC HIGH TEMPERATURE IN CHAMBER ON CONTROL 45 ℃ O/P:FULL LOAD Ta= 45 ℃ NO DAMAGE +0.03 %(0~50℃) HUMIDITY= TEMPERATURE COEFFICIENT 6 TEST: OK AFTER 12 HOURS TURN ON TEST VIBRATION TEST I/P: 230 P ℃ HIGH HUMIDITY HIGH VOLTAGE 5 -25 TEST: OK P 95 %R.H VAC + 0.01 %(0~50℃) P O/P:FULL LOAD 1 Set Operating at I/P: 230 VAC NO LOAD TEST: OK (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle P (4) Acceleration:5G (5) Test Time:1 hour in each axis (X.Y.Z) (6) Ta:25℃ Model:RQ-50C Test Report 3 / 5 RQ-50 series 50W Quad Output Switching Power Supply SAFETY TEST NO 1 TEST ITEM SPECICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: I/P-O/P: 3.6 KVAC/min I/P-O/P: 4.87 mA 1.5 KVAC/min I/P-FG: 1.8 KVAC/min I/P-FG: 4.21 O/P-FG: 0.5 KVAC/min O/P-FG: 0.6 Ta:25℃ KVAC/min O/P-FG: 3.14 I/P-FG: 2 3 4 ISOLATION RESISTANCE 3 KVAC/min VERDICT mA P mA NO DAMAGE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: I/P-FG: 500VDC>100MΩ I/P-FG: 500 VDC I/P-FG: 6G Ω 5G Ω O/P-FG:500VDC>100MΩ O/P-FG: 500 Ta:25℃ VDC O/P-FG: 4G Ω GROUNDING CONTINUITY FG(PE) TO CHASSIS 2min APPROVAL OR TRACE < 100 mΩ TUV: Certificate NO :R50046939 40 A / Ta:25℃ P NO DAMAGE 6 mΩ P P UL: File NO :E183223 E.M.C TEST NO 1 2 3 4 5 TEST ITEM SPECICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P: 230 PASS CLASS A O/P:FULL LOAD Ta:25℃ EN55022 I/P: 230 CLASS B O/P:FULL/50% LOAD Ta:25℃ Test by certified Lab EN55022 I/P: 230 PASS CLASS B O/P:FULL LOAD Ta:25℃ Test by certified Lab EN61000-4-2 I/P: 230 CRITERIA A INDUSTRY AIR:8KV / Contact:4KV O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 INDUSTRY O/P:FULL LOAD Ta:25℃ CONDUCTION RADIATION E.S.D E.F.T INPUT: 2KV 6 SURGE VAC/50HZ VAC (50HZ) VAC (50HZ) VAC/50HZ VAC/50HZ IEC61000-4-5 I/P: 230 INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :2KV VAC/50HZ VERDICT P PASS P P P CRITERIA A P CRITERIA A P L,N-PE:4KV 7 Test by certified Lab & Test Report Prepare M.T.B.F & LIFE CYCLE CALCULATION NO 1 TEST ITEM SPECICATION CAPACITOR SUPPOSE C 56 IS THE MOST CRITICAL COMPONENT I/P: 230 VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME= 85015 HRS LIFE CYCLE I/P: 230 VAC 2 MTBF TEST CONDITION O/P:FULL LOAD Ta= 45 ℃ RESULT VERDICT P LIFE TIME= 25586 HRS MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE: 162.9K P HRS Model:RQ-50C Test Report 4 / 5 RQ-50 series 50W Quad Output Switching Power Supply COMPONENT STRESS TEST NO 1 TEST ITEM SPECICATION TEST CONDITION Power Transistor Q 1 I/P:High-Line +3V = ( D to S) or (C to E) Peak Voltage 2SK2628: 600 V 6 A Rated 267 RESULT V O/P: (1)Full Load Turn on (2) Full Load VERDICT (1) 410 V (2) 546 V (3) 558 V P (3)Output Short Ta:25℃ 2 Diode Peak Voltage I/P:High-Line +3V = D 55 Rated MBR1545 :45 V 15 A D 50 267 V O/P: (1)Full Load Turn on Rated (1) 31.6 V (2) Full Load (2) 35.2 V (3)Output Short (3) 31.4 V (1)Full Load Turn on BYQ20X-200 : 200 V 10 A (1) 64 V (2) Full Load (2) 73.6 V (3)Output Short (3) 63.6 V (1)Full Load Turn on (1) 43.2 V (2) Full Load (2) 49.8 V (3)Output Short (3) 50 V (1)Full Load Turn on (1) 94 V (2) Full Load (2) 110 V (3) 110 V P D 56 Rated SR360 : 60V D 58 3A Rated HER305 : 400 V 3A (3)Output Short Ta:25℃ 3 Clamp Diode Peak Voltage D1 Rated I/P:High-Line +3V = EGP20J: 600 V2 A 267 V O/P: (1)Full Load (1) 576 V (2) 532 V (2) Dynamic Load P 90%Duty/1KHz Ta:25℃ 4 Input Capacitor Voltage C 5 Rated I/P:High-Line +3V = 267 RUBYCON : 100 u/ 400 V (1) 386 V O/P: (1)Full Load V (2) 384 V (2) Min load (3) 374 V P (3)Full Load /Min load Change Ta:25℃ 5 Control IC Voltage Test U1 Rated 1203 : I/P:High-Line +3V = 267 16 V (1) 12.9 V O/P: (1)Full Load V (2) 12.9 V (2) Min load (3) 10.5 V P (3)Full Load /Min load Change Ta:25℃ DATE 2004/3/2 2004/6/17 2004/11/3 SAMPLE RD SAMPLE PRODUCT SAMPLE A403C24 PRODUCT SAMPLE W0410B13 TEST RESULT TESTER APPROVAL PASS VINCENT TSENG MAX LIN PASS VINCENT TSENG MAX LIN VINCENT TSENG MAX LIN PASS 2003/12/12 A50-F023 Model:RQ-50C Test Report 5 / 5