BAC Controls TABLE OF CONTENTS D2 BAC CONTROLS D6 OPTIONS PRODUCT & APPLICATION HANDBOOK VOLUME V D1 Continuously providing solutions to the industry, BAC provides a full range of control panels, engineered to meet every application. BAC control packages have been designed to work seamlessly on all BAC evaporative cooling products. From the single point solution of the Combined Drive to the versatility and reliability of the Variable Frequency Drive, BAC can simplify and meet your application needs. D2 Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M BAC Controls: Custom Engineered Designed for your specific application. From safety switches to combined drives. Δ Δ Δ Industrial Grade Components Δ Easy Installation Δ Single Source Solution Energy Indoor/Outdoor Standard Applications Compliant PRODUCT & APPLICATION HANDBOOK VOLUME V D3 BAC Controls Benefits ››Single Source Solution `` BAC has designed the controls taking into consideration the exact specifications of the fan and spray pump motors, heaters, and other accessories, providing you with a single source solution. ››Indoor/Outdoor Application `` BAC offers a variety of enclosures for location flexibility; whether in a mechanical equipment room or outside next to the equipment. ››Industrial Grade Components `` IEC contactors are provided with all BAC combined drive enclosures. Combined Drive Enclosure NEMA contactors are provided with all BAC standard enclosed controls (25 amps and above). Circuit breaker protection is provided for the main panel as well as separate circuit breakers for each motor. Each control panel is UL/CSA or UL/CUL rated. ››Ease of Installation `` Combined Drive Enclosures incorporate the VFD into the controls enclosure, offering a standardized, compact single enclosure, prewired for a single-point field connection. Contact your local BAC Representative for availability. ››Energy Standard Compliance `` BAC Controls can help you comply with the speed control requirements of current energy standards and codes such as ASHRAE Standard 90.1 and California Title 24. These standards require all fan motors 7.5 HP and above to have the ability to run at 2/3 or less of full speed. BAC offers many alternatives to comply with this requirement, depending on your unique system needs. These methods include Variable Frequency Drives, the BALTIGUARD™ and BALTIGUARD PLUS™ Fan Systems, or multi-speed motors. The automatic motor speed control requirements of these standards can be satisfied through the controllers and temperature/pressure sensors available with BAC Controls for any of these methods. D4 Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M VFD with Pre-wired Terminal Box NOTE: The fan motors, spray pump motors, and other electrical accessories must be powered separately. BAC Controls Options ››BAC Equipment Control Packages By using the Combined Drive Enclosure (CDE), the Enclosed Control Package, or a VFD with an external Enclosed Control Package, BAC offers a complete controls solution for every option available on BAC’s products. Each control package is specially engineered to seamlessly integrate controls into your new BAC equipment with any combination of fans, spray pumps, basin heaters and other protective options. ››Combined Drive Enclosure (CDE) Combined Drive Enclosure includes BALTILOGIC sequencing software that is pre-programmed into the VFD to offer temperature based control of auxiliary fan motors (BALTIGUARD PLUS™Fan System). Baltilogic sequencing software also controls the spray pump starters, basin heaters, vibration cutout switches, electronic water level control, and positive closure dampers. The combined drive enclosure is UL508A/CUL rated. Combined Drive Enclosure (NEMA 3R Shown) `` BALTILOGIC SEQUENCING SOFTWARE • Simplified user interface allows quick and easy access to commonly adjusted parameters. • Incorporates start-up wizard `` COMBINED DRIVE ENCLOSURE COVER CONTROLS • Easy to follow operator logic • Complete auto control mode • Hand mode for manual operation `` BAC FACTORY START-UP • Ensures successful configuration and operation of BAC VFDs. • Extends standard two year (parts only) to three year warranty (parts and labor). `` STANDARD VFD The standard VFD includes an enclosure, 24VDC power supply, main circuit breaker, disconnect switch with lockable operator handle, 3-contactor bypass, modular cooling fan and a detachable, programmable VFD keypad. The standard VFD is UL508C/CSA rated. Combined Drive Enclosure Front Panel (NEMA 3R Shown) PRODUCT & APPLICATION HANDBOOK VOLUME V D5 BAC Controls Options `` 3-CONTACTOR BYPASS The 3-Contactor Bypass is standard on all BAC drives (excluding the ENDURADRIVE™ Fan System). The input contactor electrically isolates the drive during bypass operation. The output and bypass contactors are mechanically interlocked to regulate power to the fan motor. The bypass allows for 100% fan speed operation back-up if the drive is not functional for any reason. `` ADDITIONAL COMBINED DRIVE FEATURES INCLUDE • Main Disconnect Switch with Circuit Breaker • 24VDC Power Supply • Space Heater • 120V Transformer • Factory Pre-wired Terminal Strip Combined Drive Enclosure Cover Controls • Cover Controls • Auxiliary Fan Motor Starter (Optional) • Spray Pump Motor Starter(s) (Optional) • Basin Heater Contactor(s) (Optional) ››Standard Enclosed Controls BAC controls, designed with the highest grade components, are packed with operation-friendly features to ensure a long life expectancy and lower life cycle costs. The modular design of BAC panels allows for consistency across projects and simplifies upgrades or future replacements, yet can be customized to meet your particular application. The enclosed controls are UL 508A listed and CUL certified and are provided with a standard one year warranty (parts only). `` STANDARD PANEL WITH AUXILIARY FAN MOTOR STARTER(S) This panel includes an enclosure, control power transformer, main circuit breaker, disconnect switch with lockable operator handle, hand-off-auto switch, run pilot lights for each starter, and full voltage, non-reversing starter with overload relay and double-break silver alloy contacts. (If fan requires reverse operation, use a VFD in lieu of a fan motor starter.) `` CIRCUIT BREAKER PROTECTION Circuit breaker protection allows for quick reset and is standard for all BAC control panels. The main circuit breaker is sized for the maximum current draw for the panel configuration. Each fan motor starter includes individual branch circuit protection. D6 Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M Standard Enclosed Controls (NEMA 12 Shown) `` ADDITIONAL ENCLOSED CONTROLS FEATURES INCLUDE: • Main Disconnect Switch with Circuit Breaker • 120V Transformer • Switches, Pilot Lights & Buttons • Auxiliary Fan Motor Starter (Optional) • Temperature Controller/Operator Interface (Optional) ››Standard VFD VFDs offer many benefits including: `` Precise leaving fluid temperature control provides a more efficient method to vary airflow compared to fan cycling, fan dampers, or mechanical speed changers `` Soft-starts, stops, and smooth accelerations prolong the mechanical Standard VFD - (NEMA 3R Shown) system (fans, motors, belts, bearings, etc.) life while reducing maintenance `` The soft-start feature minimizes start-up noise and smooth acceleration making the equipment sound less noticeable to the neighbors `` Reduces wear on the motor `` ADDITIONAL VFD FEATURES INCLUDE: • Main Disconnect Switch with Circuit Breaker • Ventilation Hood • VFD Keypad/Keypad Connector • 24VDC Power Supply • Space Heater ››BALTIGUARD PLUS™ Fan System The BALTIGUARD PLUS™ Fan System builds on the advantages of the BALTIGUARD™ Fan System by adding a VFD to either the pony or the main motor, depending on system requirements. This offers the benefits of additional capacity control and energy savings, along with the redundancy offered by the BALTIGUARD™ Fan System. Alternatively, a VFD can be added to BOTH the pony and main motor, for complete capacity control and redundancy under any load. Standard Panel with Auxiliary Fan Motor Starter PRODUCT & APPLICATION HANDBOOK VOLUME V D7 BAC Controls Options Externally Mounted Terminal Box `` TERMINAL BOX (CURRENTLY AVAILABLE ON SERIES 3000, PT2, CXVB, FXV, PCC, AND VCA MODELS) All wiring for the fan motor(s) and vibration cutout switch leads are pre-wired from the factory and terminated on the outside face of the BAC unit in a clearly marked terminal box. This feature saves installation labor required to run conduit and wiring to the motor and vibration cutout switch, while saving material costs for the internal conduit, wire, couplings and hardware. The externally mounted terminal boxes are UL 1773 listed and CSA certified. The externally mounted terminal boxes are provided with a standard 5-year warranty. The terminal box includes a factory-mounted enclosure, factory wiring to terminal blocks for the fan motors and vibration cutout switches, and grounding lugs. `` ADDITIONAL TERMINAL BOX FEATURES INCLUDE: Series 3000 Terminal Box with Factory Wiring • Pre-wired in factory for unit accessories • Ships factory mounted to unit • Eliminates field casing penetrations reducing possibility of leaks and corrosion. • For VCA and PCC models all options and accessories are pre-wired ››BAC Factory Temperature/Pressure Sensor `` Proper system control is crucial to operating your system at peak efficiency under all combinations of atmospheric and load conditions. Using a BAC provided sensor ensures reliable operation and peak efficiency for the life of your unit. `` BAC temperature and pressure sensors are factory tested and approved for compatibility with all BAC control devices. High quality sensors provide accurate signals offering precise system control. Fan Starter Spray Pump Starters Basin Heater VCOS Interface EWLC BAC Factory Temperature Sensor Common Cards[1] PCD Baltilogic Startup CDE Enclosed Control[2] VFD[2] Note 1: Communication Protocols limited to Modbus, Lonworks, Johnson N2, BACNet, and Siemens APOGEE. Note 2: Enclosed Control and VFDs can be used together for complete controls solution. Note 3: ENDURADRIVE™ Fan System VFD is supplied with motor only. D8 Temperature/ Pressure Controller Q U E S T I O N S ? C A L L 4 1 0 . 7 9 9 . 6 2 0 0 O R V I S I T W W W. B A LT I M O R E A I R C O I L . C O M