DE5_P04.fm Page 4 Wednesday, January 7, 2009 3:40 PM QOB Bolt-On Circuit Breakers With VISI-TRIP® Indicator for NQ Panelboards QOB-VH 110-150 A Three-pole QOB Circuit Breaker (Bolt-on) Ampere Rating One-pole Two-pole— Common Trip Two-pole— Common Tripd Three-pole— Common Trip Catalogue No. Catalogue No. Catalogue No. Catalogue No. 120 Vac— 10,000 AIR 48 Vdc—5,000 AIR 120/240 Vac— 10,000 AIR 48 Vdc—5,000 AIRe 240 Vac— 10,000 AIR 240 Vac—10,000 AIR 48 Vdc—5,000 AIRe QOB110 QOB115 fg QOB120 fg QOB125 f QOB130 f QOB135 f QOB140 f QOB145 f QOB150 f QOB160 f QOB170 f .... .... .... .... .... QOB210 QOB215 f QOB220 f QOB225 f QOB230 f QOB235 f QOB240 f QOB245 f QOB250 f QOB260 f QOB270 f QOB280 fe QOB290 fe QOB2100 fe QOB2110 fe QOB2125 fe .... QOB215H QOB220H QOB225H QOB230H .... QOB240H .... QOB250H QOB260H QOB270H QOB280H QOB290H QOB2100H .... .... QOB310 QOB315 f QOB320 f QOB325 f QOB330 f QOB335 f QOB340 f QOB345 f QOB350 f QOB360 f QOB370 fe QOB380 fe QOB390 fe QOB3100 fe .... .... QOB200 QOB2000 .... .... QOB300 QOB3000 QOB Bolt-On 6 Spaces Required 1-pole Ampere Ratinga One-pole Catalogue No. Two-pole—Common Trip Catalogue No. QOB-GFI—QOB QWIK-GARD® Circuit Breaker With Ground Fault Circuit Interrupter—Class A 4-6 mA People Protection. b 120 Vac—10,000 AIR 120/240 Vac—10,000 AIR 15 QOB115GFI QOB215GFI 20 QOB120GFI QOB220GFI 25 QOB125GFI QOB225GFI 30 QOB130GFI QOB230GFI 40 .... QOB240GFI 50 .... QOB250GFI 60 .... QOB260GFI c QOB-VHGFI 15 20 25 30 120 Vac—22,000 AIR QOB115VHGFI QOB120VHGFI QOB125VHGFI QOB130VHGFI .... .... .... .... QOB-EPD—QOB Equipment protection circuit breakers with 30 mA equipment protection. 120 Vac—10,000 AIR 15 QOB115EPD QOB215EPD 20 QOB120EPD QOB220EPD 25 QOB125EPD QOB225EPD 30 QOB130EPD QOB230EPD 40 .... QOB240EPD 50 .... QOB250EPD 60 .... QOB260EPD QOB-HM—High magnetic trip circuit breakers are recommended DE5 PANELBOARDS for applications where high initial inrush may occur and for individual dimmer applications. 15 QOB115HMg .... 20 QOB120HMg .... QOB115AFI QOB120AFI QOB115CAFI QOB120CAFI .... .... .... .... QOBVH-AFI—QOB Arc Fault Circuit Interrupters 15 20 120 Vac—22,000 AIR QOB115VHAFI QOB120VHAFI .... .... QOB-K—Key operated QOB circuit breakers can be turned ON or OFF or to RESET with a special key (Catalogue No. QOK10) included with the circuit breaker. 120 Vac—10,000 AIR 10 QOB110K .... 15 QOB115K .... 20 QOB120K .... 25 QOB125K .... 30 QOB130K .... QO/QOB Circuit Breaker Wire Sizes Breaker Type Ampere Rating QOB 1-pole 10–30 10–30 35–70 10–30 10–30 35–70 80–125 150–200 10–30 35–70 80–125 110–150 15–20 15–30 40, 50, 60 QOB 2-pole QOB 3-pole QOB-VH QOT QOB-GFI & QOB-EPD Molded Case Switch 60 A max - 240 Vac Molded Case Switch 100 A max - 240 Vac QOB-VH 15 20 25 30 40 50 60 70 80 90 100 110 125 150 120 Vac— 22,000 AIR 120/240 Vac — 22,000 AIR QOB115VHfg QOB120VHfg QOB125VHf QOB130VHf .... .... .... .... .... .... .... .... .... .... QOB215VHf QOB220VHf QOB225VHf QOB230VHf QOB240VHf QOB250VHf QOB260VHf QOB270VHf QOB280VHf QOB290VHf QOB2100VHfh QOB2110VHfh QOB2125VHfh QOB2150VH i 120 Vac— 65,000 AIR 120 Vac/240 Vac— 65,000 AIR QHB115f g QHB120f g QHB125f QHB130f QHB215f QHB220f QHB225f QHB230f 240 Vac—22,000 AIR QOB315VHf QOB320VHf QOB325VHf QOB330VHf QOB340VHf QOB350VHf QOB360VHf QOB370VHf QOB380VHf QOB390VHf QOB3100VHf QOB3110VH i QOB3125VH i QOB3150VH i .... .... .... .... .... .... .... .... .... .... .... .... .... .... QHB 15 20 25 30 240 Vac—65,000 AIR QHB315f QHB320f QHB325f QHB330f .... .... .... .... QOB-HID—HID circuit breakers are for use on circuit feeding fluorescent and High Intensity Discharge QOB-AFI—QOB Arc Fault Circuit Interrupters 15 20 15 20 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 Wire Size (AWG) Al Cu #14–8 #14–8 ... (2) #14–10 #8–2 #8–2 #14–8 #14–8 ... (2) #14–10 #8–2 #8–2 #4–2/0 #4–2/0 #4–300 kcmil #4–300 kcmil #14–8 #14–8 #8–2 #8–2 #4–2/0 #4–2/0 #4–300 kcmil #4–300 kcmil #12–8 #14–8 #12–8 #14–8 #12–4 #14–6 (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. 15 20 25 30 40 50 120 Vac— 10,000 AIR 120/240 Vac— 10,000 AIR QOB115HIDg QOB120HID g QOB125HID QOB130HID QOB140HID QOB150HID QOB215HID QOB220HID QOB225HID QOB230HID QOB240HID QOB250HID 240 Vac—10,000 AIR .... .... .... .... .... .... QOB315HID QOB320HID QOB325HID QOB330HID .... .... QOB-SWN—Switch Neutral—Common Trip—NEC 514-5 1-pole—2-Wire 2 Spaces —120 Vac 10 15 20 25 30 40 50 .... .... .... .... .... .... .... QOB210SWN QOB215SWN QOB220SWN QOB225SWN QOB230SWN QOB240SWN QOB250SWN 2-pole—3-Wire 3 Spaces—120/240 Vac .... .... .... .... .... .... .... QOB310SWN QOB315SWN QOB320SWN QOB325SWN QOB330SWN QOB340SWN QOB350SWN QO/QOB Ring Terminal (20% Price Adder) Factory Installed Only Ampere Rating 10–30 35–60 35–50 70–110 60–100 Pole 1P, 2P, 3P 1P, 2P 3P 2P 3P Suffix 5237 5238 5238 5273 5273 a 10–30 ampere circuit breakers are suitable for use with 60°C or 75°C conductors. 35–60 ampere circuit breakers are suitable for use with 75°C conductors. b Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. c Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. d CSA Listed 5,000 AIR on 3Ø corner grounded delta systems. e DC Rating is not available on indicated products. f CSA Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. g CSA Listed as SWD (switching duty) rated suitable for switching 120 Vac fluorescent lighting loads. h 100 A max circuit breaker mounted opposite. i QOB2150VH uses 4 pole spaces. QOB3110VH, QOB3125VH and QOB3150VH each use 6 pole spaces. 20 A max circuit breaker mounted opposite. Wire size is #4–300 kcmil Al/Cu. Use with 75°C wire only. See page DE5-5 for accessories. DE5-4 12/08