001_GI004 - INTERIOR PARTITION TYPES

advertisement
3
STRUCTURE
ABOVE - SEE
BUILDING
SECTION
DEFLECTION TRACK AT NON-BEARING
PARTITIONS (FIRETRACK AT RATED
PARTITIONS)
DEFLECTION TRACK AT NON-BEARING
PARTITIONS (FIRETRACK AT RATED
PARTITIONS)
STRUCTURE
ABOVE - SEE
BUILDING
SECTION
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE
SEALANT AT RATED PARTITIONS
5
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
STRUCTURE
ABOVE - SEE
BUILDING
SECTION
6
DEFLECTION TRACK AT NON-BEARING
PARTITIONS (FIRETRACK AT RATED
PARTITIONS)
FILL ALL VOIDS AT HEAD OF CONCRETE
PARTITION TO STRUCTURAL DECK ABOVE WITH
UL APPROVED JOINT SYSTEM
STRUCTURE
ABOVE - SEE
BUILDING
SECTION
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
STRUCTURE
ABOVE - SEE
BUILDING
SECTION
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
1" SHAFT WALL GYPSUM LINER PANEL
METAL STUDS BRACED BACK TO CONC/CMU AT
THIRD POINTS
5/8" GYPSUM WALLBOARD - SEE PARTITION TAG
FOR TYPE DESIGNATION
1/2" RESILIENT CHANNEL WHERE
INDICATED
1/2" RESILIENT CHANNEL WHERE INDICATED
SOUND ATTENUATION BLANKETS WHERE
INDICATED - THICKNESS TO MATCH STUD
DEPTH
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
PARTITION TYPE S
3/4" = 1'-0"
_
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
SOUND ATTENUATION BLANKETS
IF INDICATED (IF SOUND
BLANKETS ARE NOT REQUIRED, :
INDICATES THE POSITION OF THE
STUD CAVITY
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
3/4" = 1'-0"
HEIGHT OF PARTIAL HEIGHT
WALL IF INDICATED
FIRE RATING; NONE IF NO MARK
(*)
SOUND ATTENUATION BLANKETS WHERE
INDICATED - THICKNESS TO MATCH STUD
DEPTH
PARTITION TYPE H
STUD SIZE
STEEL STUD - SB = BEARING;
S= NON-BEARING
SHAFTWALL ASSEMBLY
RESILIENT CHANNEL IF INDICATED
SOUND ATTENUATION BLANKETS
IF INDICATED
SOUND ATTENUATION BLANKETS IF
INDICATED
RESILIENT CHANNEL IF INDICATED
GWB TYPE DESIGNATOR:
_
T = TILE BACKER
L = TYPE 'X' LINER BOARD
F = FOIL BACKED
S = ACOUSTICALLY ENHANCED BOARD
- = NO GWB; CHASE WALL
OPTIONAL DESIGNATORS:
GWB TYPE DESIGNATOR:
A = TYPE 'X' ABUSE RESISTANT
X = TYPE 'X' ABUSE RESISTANT
R = REGULAR
M = MOISTURE RESISTANT
G = MOISTURE RESISTANT TYPE 'X'
STUD SIZE:
_
T = TILE BACKER
L = TYPE 'X' LINER BOARD
F = FOIL BACKED
S = ACOUSTICALLY ENHANCED BOARD
_
2 = 2 1/2"
4 = 4"
6 = 6"
_
PARTITION MODIFIERS
_
OPTIONAL DESIGNATORS:
_
GWB AND OPTIONAL DESIGNATORS READ FROM THE SIDE OF THE PARTITION WHERE THE
TAG IS LOCATED AND ACROSS THE WIDTH OF THE PARTITION.
WHERE SOUND BATTS ARE INDICATED, PROVIDE ACOUSTICAL SEAL AT TOP OF PARTITION
TO ROOF/FLOOR DECK ABOVE (COMPLETELY FILL FLUTES AT METAL DECKING)
NOTES:
GWB AND OPTIONAL DESIGNATORS READ FROM THE SIDE OF THE PARTITION WHERE THE
TAG IS LOCATED AND ACROSS THE WIDTH OF THE PARTITION.
PARTITION TYPE SC
PRECAST CONCRETE WALL THICKNESS
HEIGHT OF PARTIAL HEIGHT
WALL IF INDICATED
FIRE RATING; NONE IF NO MARK
SC = STUD CHASE WALL
_
A = TYPE 'X' ABUSE RESISTANT
X = TYPE 'X' ABUSE RESISTANT
R = REGULAR
M = MOISTURE RESISTANT
G = MOISTURE RESISTANT TYPE 'X'
STUD SIZE:
_
T = TILE BACKER
L = TYPE 'X' LINER BOARD
F = FOIL BACKED
S = ACOUSTICALLY ENHANCED BOARD
1 = 7/8"
2 = 1 5/8"
3 = 2 1/2"
4 = 3 5/8"
C = 1/2" RESILIENT CHANNEL (RC-1)
B = SOUND ATTENUATION BLANKET
OPTIONAL DESIGNATORS:
_
_
UL FIRE RATINGS (NON-BEARING): _
UL FIRE RATINGS (BEARING):
30 = 30 MINUTE; UL - U905
1 = 1 HOUR; UL - U905
2 = 2 HOUR; UL - U905
3 = 3 HOUR; UL - U904
4 = 4 HOUR; UL - U901
30 = 30 MINUTE; UL - U905
1 = 1 HOUR; UL - U905
2 = 2 HOUR; UL - U905
3 = 3 HOUR; UL - U904
4 = 4 HOUR; UL - U901
_
OPTIONAL FINISH DESIGNATOR:
P = VENETIAN PLASTER
T = CERAMIC TILE
_
WHERE SOUND BATTS ARE INDICATED, PROVIDE ACOUSTICAL SEAL AT TOP OF PARTITION
TO ROOF/FLOOR DECK ABOVE (COMPLETELY FILL FLUTES AT METAL DECKING)
_
D
1 = 1 HOUR; UL - U420
2 = 2 HOUR; UL - U420
_
_
8 = 7 5/8"
10 = 9 5/8"
12 = 11 5/8"
OPTIONAL FINISH DESIGNATOR:
_
A = TYPE 'X' ABUSE RESISTANT
X = TYPE 'X' ABUSE RESISTANT
R = REGULAR
M = MOISTURE RESISTANT
G = MOISTURE RESISTANT TYPE 'X'
T = TILE BACKER
L = TYPE 'X' LINER BOARD
F = FOIL BACKED
S = ACOUSTICALLY ENHANCED BOARD
-- = NO GWB; CHASE WALL
STUD SIZE:
OPTIONAL DESIGNATORS:
1 = 1 5/8"
2 = 2 1/2"
3 = 3 5/8"
_
4 = 4"
6 = 6"
8 = 8"
_
B = SOUND ATTENUATION BLANKET
: = INDICATES STUD CAVITY
NOTES:
GWB AND OPTIONAL DESIGNATORS READ FROM THE SIDE OF THE PARTITION WHERE THE
TAG IS LOCATED AND ACROSS THE WIDTH OF THE PARTITION.
NOTES:
Jane C. Wright, License #11299
Expiration Date 12/31/2015
WHERE SOUND BATTS ARE INDICATED, PROVIDE ACOUSTICAL SEAL AT TOP OF PARTITION
TO ROOF/FLOOR DECK ABOVE (COMPLETELY FILL FLUTES AT METAL DECKING)
AT HIGH PERFORMANCE ACOUSTIC WALLS (ALL PARTITIONS AND FURRING UTILIZING TYPE
'S' ACOUSTICALLY ENHANCED GYPSUM BOARD) PROVIDE ACOUSTICAL SEALANT AT ALL
WALL PENETRATIONS (ANNULAR SPACE BETWEEN GYPSUM BOARD AND PENETRATION) AND
ACOUSTICAL PUTTY PADS AT ALL ELECTRICAL, TELECOMMUNICATION AND DATA OUTLET
BOXES. SEAL PERIMETER OF PARTITION WITH ACOUSTICAL SEALANT TO ALL ADJOINING
CONSTRUCTION.
AT HIGH PERFORMANCE ACOUSTIC WALLS (ALL PARTITIONS AND FURRING UTILIZING TYPE
'S' ACOUSTICALLY ENHANCED GYPSUM BOARD) PROVIDE ACOUSTICAL SEALANT AT ALL
WALL PENETRATIONS (ANNULAR SPACE BETWEEN GYPSUM BOARD AND PENETRATION) AND
ACOUSTICAL PUTTY PADS AT ALL ELECTRICAL, TELECOMMUNICATION AND DATA OUTLET
BOXES. SEAL PERIMETER OF PARTITION WITH ACOUSTICAL SEALANT TO ALL ADJOINING
CONSTRUCTION.
WHERE NOTED ON THE PLAN OR ENLARGED PLANS - C INDICATES THE SIDE OF THE
PARTITION FOR THE RESILIENT CHANNEL
RESILENT CHANNEL IF INDICATED
UL FIRE RATINGS (NON-BEARING): _
_
2 = 1 5/8"
4 = 3 5/8"
6 = 5 5/8"
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
PARTITION MODIFIERS
D = DECORATIVE FACE
F = FLUSH STRUCK
MASONRY SIZE:
AT HIGH PERFORMANCE ACOUSTIC WALLS (ALL PARTITIONS AND FURRING UTILIZING TYPE
'S' ACOUSTICALLY ENHANCED GYPSUM BOARD) PROVIDE ACOUSTICAL SEALANT AT ALL
WALL PENETRATIONS (ANNULAR SPACE BETWEEN GYPSUM BOARD AND PENETRATION) AND
ACOUSTICAL PUTTY PADS AT ALL ELECTRICAL, TELECOMMUNICATION AND DATA OUTLET
BOXES. SEAL PERIMETER OF PARTITION WITH ACOUSTICAL SEALANT TO ALL ADJOINING
CONSTRUCTION.
_
STUD SIZE
FIRE RATING; NONE IF NO MARK
HEIGHT OF PARTIAL HEIGHT
SC3 -1
XXBCXX (*) WALL IF INDICATED
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
SOUND ATTENUATION BLANKETS IF
INDICATED (IF SOUND BLANKETS ARE
NOT REQUIRED, : INDICATES THE
POSITION OF THE STUD CAVITY
OPTIONAL FINISH DESIGNATION
PARTITION MODIFIERS
NOTES:
GWB AND OPTIONAL DESIGNATORS READ FROM THE SIDE OF THE PARTITION WHERE THE
TAG IS LOCATED AND ACROSS THE WIDTH OF THE PARTITION.
C = 1/2" RESILIENT CHANNEL (RC-1)
B = SOUND ATTENUATION BLANKET
NOTES:
C = 1/2" RESILIENT CHANNEL (RC-1)
B = SOUND ATTENUATION BLANKET
: = INDICATES STUD CAVITY
OPTIONAL FINISH DESIGNATION
_
GWB TYPE DESIGNATOR
6 = 6"
8 = 8"
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE
SEALANT AT RATED PARTITIONS
CP8-1
- -
RESILIENT CHANNEL IF INDICATED
_
(*)
F2
-BCX
_
SOUND ATTENUATION BLANKETS WHERE
INDICATED - THICKNESS TO MATCH STUD
DEPTH
3/4" = 1'-0"
PRECAST CONCRETE
WALL ASSEMBLY
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
1 = 1 HOUR; UL - U415
2 = 2 HOUR; UL - U415
4 = 4"
6 = 6"
8 = 8"
(*)
HEIGHT OF PARTIAL HEIGHT
WALL IF INDICATED
DASH INDICATES NO GWB THIS
SIDE
20 = 20 MINUTES; UL - U423
30 = 30 MINUTES; UL - U423
1 = 1 HOUR; UL - U423
2 = 2 HOUR; UL - U423
3 = 3 HOUR; UL - U423
4 = 4 HOUR; UL - U423
1 = 1 5/8"
2 = 2 1/2"
3 = 3 5/8"
FURRING ASSEMBLY
_
3/4" = 1'-0"
STUD SIZE
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
20 = 20 MINUTES; UL - U419
30 = 30 MINUTES; UL - U419
1 = 1 HOUR; UL - U419
2 = 2 HOUR; UL - U419
3 = 3 HOUR; UL - U419
4 = 4 HOUR; UL - U419
_
PARTITION TYPE CP
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
UL FIRE RATINGS (NON-BEARING): _
STUD SIZE:
3/4" = 1'-0"
PARTITION MODIFIERS
NOTE: SEE
ROOM FINISH
SCHEDULE FOR
CEILING, FLOOR
AND BASE
FINISHES
NOTE: SEE ROOM FINISH SCHEDULE FOR
CEILING, FLOOR AND BASE FINISHES
_
GWB TYPE FOR EA LAYER - SEE
TABLE BELOW FOR TYPES
UL FIRE RATINGS ('SB' PARTITIONS): _
A = TYPE 'X' ABUSE RESISTANT
X = TYPE 'X' ABUSE RESISTANT
R = REGULAR
M = MOISTURE RESISTANT
G = MOISTURE RESISTANT TYPE 'X'
CONT ACOUSTIC SEALANT AT NON-RATED
PARTITIONS AND UL APPROVED FIRE SEALANT
AT RATED PARTITIONS
H2-1
XXCBL
_
5/8" GYPSUM WALLBOARD - SEE PARTITION
TAG FOR TYPE DESIGNATION
CONCRETE OR CMU AT SOME LOCATIONS SEE PLANS FOR PARTITION TYPE
NOTE: SEE
ROOM FINISH
SCHEDULE FOR
CEILING, FLOOR
AND BASE
FINISHES
PARTITION TYPE F
HEIGHT OF PARTIAL HEIGHT
WALL IF INDICATED
FIRE RATING; NONE IF NO MARK
(*)
UL FIRE RATINGS ('S' PARTITIONS): _
_
_
STUD SIZE
S3-30
XXBCXX
PARTITION MODIFIERS
D
NOTE: SEE
ROOM FINISH
SCHEDULE FOR
CEILING, FLOOR
AND BASE
FINISHES
E
5/8" GYPSUM WALLBOARD - SEE PARTITION TAG
FOR TYPE DESIGNATION
AT HIGH PERFORMANCE ACOUSTIC WALLS (ALL PARTITIONS AND FURRING UTILIZING TYPE
'S' ACOUSTICALLY ENHANCED GYPSUM BOARD) PROVIDE ACOUSTICAL SEALANT AT ALL
WALL PENETRATIONS (ANNULAR SPACE BETWEEN GYPSUM BOARD AND PENETRATION) AND
ACOUSTICAL PUTTY PADS AT ALL ELECTRICAL, TELECOMMUNICATION AND DATA OUTLET
BOXES. SEAL PERIMETER OF PARTITION WITH ACOUSTICAL SEALANT TO ALL ADJOINING
CONSTRUCTION.
PRINTED: 5/8/2014 4:40:13 PM
C
C
PARTITION TYPES
FIRE SMOKE DAMPER AND DUCT SEE
MECHANICAL DRAWINGS FOR LOCATIONS
3/4" = 1'-0"
(2) LAYERS 5/8" TYPE 'X' GYPSUM BOARD ON
2 1/2" COLD FORMED METAL STUDS
J RUNNER COLD FORMED METAL FRAMING TYPICAL
6" WIDE X 6" TALL CONTINUOUS CAST IN
PLACE CONCRETE CURB SEE STRUCTURAL
DRAWINGS FOR NOTES COORDINATE
EXACT LOCATION WITH ARCHITECTURAL
PLAN DIMENSIONS
PRECAST WALL PANEL WITH FACTORY FORMED
ROUGH OPENING FOR FVC CABINET TYPICAL
FLOOR DRAIN BEYOND SEE PLUMBING
DRAWINGS FOR NOTES
B1
VERIFY WITH MANUFACTURER
LAUNDRY ROOM CURB
1 1/2" = 1'-0"
0'
8"
1'-4"
2'
B2
2 1/2" C-H STUD COLD FORMED METAL FRAMING
(2) LAYERS 1/2” TYPE "C" FIRECODE BOARD
ON 2 1/2" C-H STUDS WITH 1" TYPE "X" LINER
BOARD PER UL DESIGN U415 TYPICAL
SEMI-RECESSED FIRE EXTINGUISHER
CABINET (FEC) SEE ARCHITECTURAL
PLANS FOR LOCATIONS SEE MOUNTING
HEIGHTS ON SHEET GI005
RETAINING ANGLES TYPICAL
1 1/2" = 1'-0"
0'
8"
1'-4"
2'
B4
B
FIRE RATED SEALANT TYPICAL
TOPPING SLAB ON CORE PLANKS TYPICAL
PROVIDE MINIMUM 2-HOUR RATING A SLAB EDGE
INTERMEDIATE FLOOR DETAIL
FVC ENCLOSURE DETAIL
1 1/2" = 1'-0"
0'
8"
1'-4"
PARTITION TYPE AS SCHEDULED SEE PLANS
ALIGN FACE OF STUD WITH EDGE OF CURB
3'-0"
6"
FIRST FLOOR
100' - 0"
CONTINUOUS SEALANT JOINT PROVIDE
FIRE RATED SEALANT AS APPLICABLE TO
PARTITION TYPE TYPICAL
SLAB ON GRADE SEE STRUCTURAL
DRAWINGS FOR NOTES
6"
TOPPING SLAB ON CORE PLANKS TYPICAL
PROVIDE MINIMUM 2-HOUR RATING A SLAB EDGE
FLAT SCREEN MONITOR RECESSED WALL
MOUNT BOX. MODEL: PREMIER INW-AM200
BASE AS SCHEDULED
A
FIRE SMOKE DAMPER AND DUCT WHERE DAMPER
RESIDES ABOVE FIRST FLOOR & NO SHAFT
ASSEMBLY EXISTS BELOW SEE ARCHITECTURAL
PLANS & MECHANICAL DRAWINGS FOR LOCATIONS
TERMINATION SECOND FLOOR SLAB
CONTINUOUS SEALANT JOINT PROVIDE
FIRE RATED SEALANT AS APPLICABLE TO
PARTITION TYPE TYPICAL
3'-0"
1" SHAFTLINER - MAINTAIN FIRE RATED
ENCLOSURE BEHIND RECESSED UNIT
3 1/2" SOUND
ATTENUATION BATTS EXTEND 3'-0" BOTH SIDES
OF PARTITION - TYP
0'
1
8"
1'-4"
9 MAY 2014
CONFORMED DOCUMENTS
100%
18 DEC 2013
100% CD SUBMITTAL
95%
08 NOV 2013
95% CD SUBMITTAL
CD
14 OCT 2013
CD PROGRESS
DD
12 JUL 2013
DD SUBMITTAL
ELEVATOR DOOR FRAME
SEE REFLECTED
CEILING PLANS
(2) LAYERS 1/2” TYPE "C" FIRECODE
BOARD ON 2 1/2" C-H STUDS WITH 1"
TYPE "X" LINER BOARD PER NER-258
GWB PARTITION - SEE FLOOR PLAN FOR
PARTITION TYPE
(2) LAYERS 1/2” TYPE "C" FIRECODE BOARD
ON 2 1/2" C-H STUDS WITH 1" TYPE "X" LINER
BOARD PER UL DESIGN U415 SEE PLANS FOR
LOCATIONS AT FIRST FLOOR TYPICAL
A
DESCRIPTION
PROJECT NO:
12024.00
DRAWN BY:
RMC
CHECKED BY:
JKS
COPYRIGHT © 2013
HANBURY EVANS WRIGHT VLATTAS + COMPANY
SHEET TITLE:
SUSPENDED ACOUSTICAL
PANEL CEILING SYSTEM
CONTAINMENT CURB
1 1/2" = 1'-0"
SE
-
MARK DATE
TERMINATION SLAB ON GRADE
(TERMINATION TO UNDERSIDE OF
CORE PLANKS SIMILAR)
(2) LAYERS 5/8" TYPE 'X' GYPSUM BOARD
ON 1 5/8" COLD FORMED METAL STUDS
INTERIOR PARTITION
TYPES
(2) LAYERS 5/8" TYPE 'X' GYPSUM BOARD
ON 6" C-H COLD FORMED METAL STUDS
CONTINUOUS SEALANT
A1
SW
2'
24" FLAT SCREEN MONITOR - OWNER
PROVIDED
FLAT SCREEN MONITOR SWING-ARM MOUNT
MODEL: PREMIER AM50-B
6" WIDE X 6" TALL CONTINUOUS CAST IN
PLACE CONCRETE CURB SEE STRUCTURAL
DRAWINGS FOR NOTES COORDINATE
EXACT LOCATION WITH ARCHITECTURAL
PLAN DIMENSIONS
LC
FIRE EXTINGUISHER CABINET
N.15
MECH ROOM SIDE
NE
NW
LINE OF FINISHED CEILING AS SCHEDULED TYPICAL
MAINTAIN WALL FIRE RATING BEHIND
PRECAST ROUGH IN OPENING - PROVIDE
FIRE RATED FEC WHERE RATING CANNOT
BE MAINTAINED (GYPSUM BOARD
ASSEMBLIES) TYPICAL
FVC CABINET SEE FIRE PROTECTION
PLANS AND ARCHITECTURAL PLANS FOR
DIMENSIONED LOCATIONS
25"X25" ROUGH OPENING
SLAB ON GRADE SEE STRUCTURAL
DRAWINGS FOR NOTES
1" TYPE "X" LINER BOARD
KEYPLAN
B
FIRE DEPARTMENT CONNECTION VALVE
SEAL PIPE PENETRATION AT GYPSUM
BOARD WITH RATED SEALANT TYPICAL
RADIUSED CORNERS TYPICAL
FIRST FLOOR
100' - 0"
ROUGH OPENING DIMENSIONS
FLOOR FINISH AS SCHEDULED EXTEND
UP CURB AND DOWN BACK SIDE TYPICAL
PRECAST WALL PANEL WITH FACTORY
FORMED ROUGH OPENING FOR FEC
TO BE VARIFIED WITH MANUFACTURER
CONTINUOUS SEALANT JOINT TYPICAL
ROOM SIDE
(2) LAYERS 1/2” TYPE "C" FIRECODE
BOARD ON 2 1/2" C-H STUDS WITH 1"
TYPE "X" LINER BOARD PER NER-258
TERMINATION CAP DETAIL
(ATTIC DORMER CONDITON SHOWN)
WASHING MACHINE - NIC
FILE LOCATION: H:\REVIT LOCALS\OHIO_PH1_NW_NE_jsleeman.rvt
HOUSING DEVELOPMENT
PHASE ONE
NOTE: SEE ROOM
FINISH SCHEDULE
FOR CEILING,
FLOOR AND BASE
FINISHES
5/8" GYPSUM WALLBOARD - SEE PARTITION TAG
FOR TYPE DESIGNATION
VARIES SEE PLAN
DESIGN ARCHITECT
E
PRECAST CONCRETE WALL - SEE STRUCTURAL
DRAWINGS
ATHENS, OHIO
DEFLECTION TRACK AT NON-BEARING
PARTITIONS (FIRETRACK AT RATED
PARTITIONS)
4
URS Corporation
Architects . Engineers . Planners
277 West Nationwide Blvd
Columbus, OH 43215
2
ENGINEERS | ARCHITECT OF RECORD
1
2'
A2
CEILING DETAIL LC OFFICE PARTITIONS
1 1/2" = 1'-0"
0'
2
8"
1'-4"
A3
2'
3
SHEET NUMBER:
RECESSED TV WALL MOUNT
1 1/2" = 1'-0"
0'
8"
4
1'-4"
2'
A5
SHAFT WALL DETAIL
1 1/2" = 1'-0"
SLAB ON GRADE SEE STRUCTURAL DRAWINGS
FIRE RATED SEALANT TYPICAL
0'
5
6
8"
1'-4"
2'
GI004