PROJECT INFORMATION SIMPLESEAL™ Job Name Fixture Type CSEFO SERIES – HIGH EFFICIENCY REFLECTOR LF FLANGE MOUNT –OVERLAPPING DOOR Catalog Number Approved by PRODUCT FEATURES: »»Recessed; flange mount – 2'×4' »»One-piece overlapping door provides air-tight integrity of luminaire »»Optional Food Zone/Non-Contact listing ideal for food processing applications SPECIFICATIONS HOUSING: 20-gauge CRS. Hole-free one-piece seam welded construction. White TGIC polyester powder coat finish – 5-step pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. DOORFRAME: 20-gauge type 304 stainless steel (#4 finish-post fabrication). One-piece 60° beveled perimeter construction. Continuous angle lens retention system. Mechanical guide for doorframe fastener alignment. Doorframe secured to housing with stainless steel aircraft cables and (12) captive flush mounted Phillips head stainless steel fasteners. Thumb screws used for FN option. Doorframe Gasket: One-piece closed cell extruded silicone gasket seals doorframe to housing and ceiling structure. LENS: .125" #12 high impact acrylic lens sealed to perimeter ledge of lens aperture with silicone sealant and secured with continuous lens retention system. L­ ens orientation – smooth side out. See Options for alternate lens selections. If required, specify lens overlay combinations inner/outer (Example: R/T). FN option includes FDA approved Food Zone clear polycarbonate lens. Can be combined with prismatic inner lens (specify type in Lens Type field). OPTICS: High performance specular aluminum reflector system with 95% reflectivity yields 85.3% efficiency; ITL Test Report #62999. ELECTRICAL: Quantity and type as specified – see ordering information. All ballasts UL listed class P. Wireway hole provided with hub/ring assembly. See Ordering Information for alternate or multiple ballasts, sealed wireway and optional equipment. Lamps by others. INSTALLATION: Adjustable swing-out mounting brackets standard. See Options for continuous row mounting and plaster frames. LISTINGS: UL and CUL Listed for Wet Location. UL certified IP65 per IEC 60598. NSF2 Splash/Non-Food. Optional NSF2 Food Zone/Non-Contact. Meets K230 Leakage Standard for luminaire leakage in pressurized environments and FED-STD-209E/Class 100 (ISO 5) Cleanrooms. CCEA Approved. IP65 K230 ISO 5 Class 100 FN CCEA OPTION Approved ORDERING INFORMATION (Ex: CSEFO24P-2-32-IS-1-120-5F-2H-T) Model Lamp Qty/Type Ballast Type Ballast Qty Voltage Housing Doorframe Lens Type Options CSEFO24P Lamp Quantity/Type 2-32 Two F32T8 3-32 Three F32T8 4-32 Four F32T8 Voltage 120 120 Volts 277 277 Volts 347 347 Volts Lens Type Acrylic T .125" Clear U .125" #12 Prismatic High Impact Ballast Type IS Instant Start Electronic <10% THD RS Rapid Start Electronic <10% THD SB Specified Ballast Doorframe Options 5F 20-Ga Type 304 SS (STD) 2F 20-Ga CRS XF 20-Ga Type 316 SS PAF .063" Painted Fabricated Aluminum Polycarbonate 2 .125" #12 Prismatic G .125" Clear Ballast Quantity 1One 2Two Housing Options 2H 20-Ga CRS (STD) 5H 20-Ga Type 304 SS XH 20-Ga Type 316 SS PAH .050" Painted Aluminum Tempered Glass R .156" C73 Glass Specified Lens SL Specified Lens Options EL Standard Lumen EL Pack PEL High Lumen EL Pack SEL Specified EL Pack FN** Food Zone/Non-Contact FS Fuse & Holder HJ Sealed Wireway RF Radio Frequency Filter PF Plaster Frame RM Continuous Row Mounting UV UV Filtering Lens (Specify) ** Only available in combination with a prismatic inner lens (specified in Lens Type). For nonprismatic, only the FDA approved Food Zone clear polycarbonate lens will be provided (leave Lens Type blank). NOTE: Clear lens option will provide slightly higher efficiencies with increased perceived brightness. DIMENSIONAL DATA GASKET PROFILE Fixture Housing Gasket mechanically retained Doorframe CROSS SECTION CEILING CUTOUT Ceiling Line 4.75" 21.86" 23.36"×49.72" Doorframe www.kenall.com P: 800-4-Kenall F: 262-891-9701 48.22" 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. CSEFO24P232_332_432-040715 PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL62999 DATE: 09/09/09 PREPARED FOR: KENALL LIGHTING REVISED: 03/12/10 CATALOG NUMBER: CSEFO24P-2-32-IS-1-120-2F-2H-U LUMINAIRE: FABRICATED METAL HOUSING WITH WHITE PAINTED GENERAL INTERIOR FINISH, FORMED METAL REFLECTOR WITH PREMIUM SPECULAR FINISH, CLEAR PRISMATIC PLASTIC LENS IN FABRICATED WHITE PAINTED METAL FRAME. LENS PRISMS UP. LAMPS: TWO 32-WATT T-8 FO32/835 LINEAR FLUORESCENTS. BALLAST: UNIVERSAL B232IUNVHP-B MOUNTING: RECESSED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 54.9 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 2950 LUMENS PER LAMP. CANDELA DISTRIBUTION 0.0 22.5 45.0 0 1777 1777 1777 5 1767 1767 1767 15 1671 1687 1722 25 1532 1572 1638 35 1334 1397 1479 45 1117 1175 1236 55 862 919 946 65 581 629 638 75 287 310 322 85 53 55 58 90 0 0 0 67.5 1777 1773 1744 1668 1476 1198 902 604 302 58 0 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 1402 0- 40 2301 0- 60 4033 0- 90 5033 90-180 0 0-180 5033 90.0 1777 1774 1749 1674 1458 1173 873 573 291 59 0 %LAMP 23.8 39.0 68.4 85.3 0.0 85.3 TOTAL LUMINAIRE EFFICIENCY = FLUX 168 486 748 899 917 815 606 324 69 %FIXT 27.9 45.7 80.1 100.0 0.0 100.0 90˚ 75˚ 600 60˚ 85.3 % 1200 CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.2 SHIELDING ANGLES : 90 LUMINOUS LENGTH :45.500 45˚ 90-DEG 1.3 90 19.187 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE AVERAGE AVERAGE IN DEG 0-DEG 45-DEG 90-DEG 45 2805. 3103. 2945. 55 2668. 2928. 2702. 65 2441. 2680. 2407. 75 1969. 2209. 1996. 85 1080. 1182. 1202. 1800 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ Checked N WHITE Approved R BEATTIE 30˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • E-MAIL: itl@itlboulder.com REPORT NUMBER: ITL62999 PREPARED FOR: KENALL LIGHTING CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 1777 1777 1777 2.5 1778 1774 1772 5.0 1767 1767 1767 7.5 1750 1750 1759 10.0 1726 1732 1748 12.5 1700 1710 1737 15.0 1671 1687 1722 17.5 1640 1665 1706 20.0 1607 1637 1686 22.5 1568 1608 1662 25.0 1532 1572 1638 27.5 1488 1539 1609 30.0 1442 1494 1574 32.5 1392 1448 1532 35.0 1334 1397 1479 37.5 1285 1340 1426 40.0 1228 1290 1361 42.5 1176 1230 1298 45.0 1117 1175 1236 47.5 1056 1118 1162 50.0 995 1053 1095 52.5 927 991 1020 55.0 862 919 946 57.5 798 852 879 60.0 723 779 800 62.5 658 706 723 65.0 581 629 638 67.5 506 548 563 70.0 428 470 478 72.5 358 388 400 75.0 287 310 322 77.5 219 240 241 80.0 155 168 171 82.5 97 109 106 85.0 53 55 58 87.5 17 21 22 90.0 0 0 0 67.5 1777 1773 1773 1770 1766 1758 1744 1732 1714 1695 1668 1636 1592 1535 1476 1407 1343 1268 1198 1131 1052 980 902 828 752 676 604 524 451 372 302 234 164 108 58 22 0 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 09/09/09 REVISED: 03/12/10 90.0 1777 1771 1774 1773 1770 1762 1749 1737 1722 1701 1674 1638 1586 1523 1458 1389 1317 1246 1173 1096 1021 947 873 802 721 652 573 504 430 359 291 223 160 104 59 25 0 ZONAL LUMEN SUMMARY 0- 5 42. 5- 10 126. 10- 15 206. 15- 20 280. 20- 25 346. 25- 30 402. 30- 35 440. 35- 40 460. 40- 45 464. 45- 50 453. 50- 55 427. 55- 60 388. 60- 65 335. 65- 70 271. 70- 75 198. 75- 80 125. 80- 85 58. 85- 90 12. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • REPORT NUMBER: ITL62999 WEBSITE: www.itlboulder.com DATE: 09/09/09 PREPARED FOR: KENALL LIGHTING REVISED: 03/12/10 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 102102102102 93 89 85 82 85 78 72 67 77 68 61 56 71 60 53 47 65 54 46 41 60 49 41 36 56 44 37 31 52 40 33 28 48 37 30 25 45 34 27 23 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 99 91 82 75 69 63 58 54 50 47 44 95 83 73 64 57 51 46 42 39 35 33 91 80 70 62 55 50 45 41 37 35 32 87 77 68 60 53 48 44 40 36 34 31 85 72 60 51 43 37 33 29 26 23 21 99 87 76 67 59 53 48 43 40 36 34 99 84 71 60 52 46 41 36 33 30 27 99 81 66 55 47 41 35 31 28 25 23 95 81 69 59 51 45 40 36 32 29 27 95 78 65 54 46 40 35 31 28 25 23 91 78 67 57 50 44 39 35 32 29 26 91 76 63 53 46 40 35 31 28 25 23 87 75 65 56 49 43 38 35 31 28 26 87 74 62 52 45 39 34 31 27 25 22 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL63000 DATE: 09/10/09 PREPARED FOR: KENALL LIGHTING REVISED: 03/12/10 CATALOG NUMBER: CSEFO24P-3-32-IS-2-120-2F-2H-U LUMINAIRE: FABRICATED METAL HOUSING WITH WHITE PAINTED GENERAL INTERIOR FINISH, FORMED WHITE PAINTED MULTI-FACETED METAL CENTER REFLECTOR, ONE FORMED MULTI-FACETED METAL REFLECTOR WITH PREMIUM SPECULAR FINISH ON EACH SIDE OF CENTER REFLECTOR, CLEAR PRISMATIC PLASTIC LENS IN FABRICATED WHITE PAINTED METAL FRAME. LENS PRISMS UP. LAMPS: THREE 32-WATT T-8 FO32/835 LINEAR FLUORESCENTS. BALLAST: UNIVERSAL B232IUNVHP-B, UNIVERSAL B132IUNVHP-B MOUNTING: RECESSED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 82.8 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 2950 LUMENS PER LAMP. CANDELA DISTRIBUTION 0.0 22.5 45.0 0 2834 2834 2834 5 2811 2817 2821 15 2646 2686 2735 25 2410 2482 2569 35 2084 2178 2249 45 1725 1802 1812 55 1313 1389 1359 65 866 938 900 75 431 464 453 85 81 87 77 90 0 0 0 67.5 2834 2829 2767 2581 2182 1719 1275 845 420 80 0 90.0 2834 2828 2773 2569 2124 1669 1235 799 407 77 0 FLUX 268 770 1166 1363 1355 1184 870 463 99 90˚ 75˚ ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 2205 0- 40 3568 0- 60 6107 0- 90 7539 90-180 0 0-180 7539 %LAMP 24.9 40.3 69.0 85.2 0.0 85.2 %FIXT 29.2 47.3 81.0 100.0 0.0 100.0 950 60˚ 1900 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.2 SHIELDING ANGLES : 90 LUMINOUS LENGTH :45.500 90-DEG 1.2 90 19.187 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE AVERAGE AVERAGE IN DEG 0-DEG 45-DEG 90-DEG 45 4331. 4550. 4191. 55 4064. 4207. 3823. 65 3638. 3781. 3357. 75 2957. 3107. 2792. 85 1650. 1569. 1569. 85.2 % 45˚ 2850 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ Checked N WHITE Approved R BEATTIE 30˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • E-MAIL: itl@itlboulder.com REPORT NUMBER: ITL63000 PREPARED FOR: KENALL LIGHTING CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 2834 2834 2834 2.5 2833 2833 2829 5.0 2811 2817 2821 7.5 2779 2790 2808 10.0 2738 2761 2786 12.5 2694 2725 2762 15.0 2646 2686 2735 17.5 2590 2645 2701 20.0 2534 2593 2664 22.5 2471 2544 2618 25.0 2410 2482 2569 27.5 2344 2417 2510 30.0 2259 2342 2436 32.5 2175 2260 2355 35.0 2084 2178 2249 37.5 1998 2083 2144 40.0 1898 1994 2029 42.5 1813 1894 1917 45.0 1725 1802 1812 47.5 1612 1711 1691 50.0 1522 1598 1586 52.5 1407 1499 1463 55.0 1313 1389 1359 57.5 1204 1276 1248 60.0 1095 1159 1134 62.5 989 1046 1019 65.0 866 938 900 67.5 759 812 790 70.0 640 694 668 72.5 536 572 560 75.0 431 464 453 77.5 329 363 336 80.0 235 250 243 82.5 146 163 148 85.0 81 87 77 87.5 28 32 31 90.0 0 0 0 67.5 2834 2830 2829 2822 2809 2790 2767 2737 2698 2652 2581 2501 2396 2292 2182 2058 1947 1825 1719 1615 1495 1393 1275 1169 1053 947 845 732 626 523 420 326 228 151 80 32 0 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 09/10/09 REVISED: 03/12/10 90.0 2834 2826 2828 2824 2811 2797 2773 2743 2703 2642 2569 2474 2364 2258 2124 2015 1892 1782 1669 1556 1456 1333 1235 1125 1019 910 799 703 599 497 407 303 222 140 77 33 0 ZONAL LUMEN SUMMARY 0- 5 68. 5- 10 201. 10- 15 327. 15- 20 443. 20- 25 544. 25- 30 622. 30- 35 672. 35- 40 692. 40- 45 688. 45- 50 667. 50- 55 622. 55- 60 561. 60- 65 482. 65- 70 388. 70- 75 284. 75- 80 179. 80- 85 82. 85- 90 17. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • REPORT NUMBER: ITL63000 WEBSITE: www.itlboulder.com DATE: 09/10/09 PREPARED FOR: KENALL LIGHTING REVISED: 03/12/10 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 101101101101 93 89 86 82 85 78 72 68 77 69 62 56 71 61 54 48 65 55 47 41 60 49 42 36 56 45 37 32 52 41 34 29 49 38 31 26 46 35 28 24 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 99 91 83 75 69 64 59 55 51 48 45 95 84 73 65 58 52 47 43 39 36 33 91 80 71 62 56 50 45 41 38 35 33 87 77 68 60 54 49 44 40 37 34 32 85 72 60 51 44 38 33 30 27 24 22 99 87 76 67 60 54 48 44 40 37 34 99 84 71 61 53 47 41 37 33 30 28 99 81 67 56 48 41 36 32 29 26 23 95 81 69 59 52 46 41 36 33 30 27 95 79 65 55 47 41 36 32 28 26 23 91 78 67 58 51 45 40 36 32 30 27 91 76 64 54 46 40 36 32 28 26 23 87 75 65 56 49 44 39 35 32 29 27 87 74 62 53 46 40 35 31 28 25 23 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL60564 DATE: 07/11/08 PREPARED FOR: KENALL LIGHTING REVISED: 03/11/10 CATALOG NUMBER: CSEFO24P-4-32-IS-1-120-2F-2H-U LUMINAIRE: FABRICATED METAL HOUSING WITH WHITE PAINTED GENERAL INTERIOR FINISH, FORMED WHITE PAINTED METAL CENTER REFLECTOR, ONE FORMED METAL REFLECTOR WITH PREMIUM SPECULAR FINISH ON EACH SIDE OF CENTER REFLECTOR, CLEAR FLAT PRISMATIC ACRYLIC LENS IN FABRICATED WHITE PAINTED METAL FRAME. LENS PRISMS UP. LAMPS: FOUR 32-WATT T-8 FO32/835 LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-4P32-SC THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL REFLECTANCE OF PAINT = 90.9 % MOUNTING: RECESSED TOTAL INPUT WATTS= 107.3 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED= 9.19 REPORT IS BASED ON 2950 LUMENS PER LAMP. CANDELA DISTRIBUTION 0.0 22.5 45.0 0 3858 3858 3858 5 3825 3827 3826 15 3592 3603 3590 25 3241 3256 3228 35 2786 2796 2794 45 2285 2287 2299 55 1750 1760 1774 65 1179 1196 1203 75 605 613 615 85 139 138 133 90 0 0 0 67.5 3858 3824 3569 3200 2759 2254 1698 1131 579 129 0 90.0 3858 3824 3557 3188 2744 2215 1645 1090 562 132 0 FLUX 363 1011 1487 1740 1755 1550 1155 634 157 90˚ 75˚ ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 2861 0- 40 4601 0- 60 7906 0- 90 9852 90-180 0 0-180 9852 %LAMP 24.2 39.0 67.0 83.5 0.0 83.5 %FIXT 29.0 46.7 80.3 100.0 0.0 100.0 1300 60˚ 2600 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.2 SHIELDING ANGLES : 90 LUMINOUS LENGTH :45.563 90-DEG 1.2 90 19.250 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE AVERAGE AVERAGE IN DEG 0-DEG 45-DEG 90-DEG 45 5711. 5746. 5536. 55 5392. 5466. 5068. 65 4930. 5031. 4558. 75 4131. 4199. 3837. 85 2818. 2697. 2676. 83.5 % 45˚ 3900 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ Checked N WHITE Approved R BEATTIE 30˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • E-MAIL: itl@itlboulder.com REPORT NUMBER: ITL60564 PREPARED FOR: KENALL LIGHTING CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 3858 3858 3858 2.5 3853 3852 3848 5.0 3825 3827 3826 7.5 3784 3788 3787 10.0 3729 3737 3731 12.5 3664 3674 3665 15.0 3592 3603 3590 17.5 3514 3525 3508 20.0 3428 3441 3419 22.5 3337 3351 3325 25.0 3241 3256 3228 27.5 3137 3153 3129 30.0 3024 3042 3023 32.5 2906 2923 2912 35.0 2786 2796 2794 37.5 2663 2670 2672 40.0 2539 2542 2548 42.5 2413 2415 2425 45.0 2285 2287 2299 47.5 2154 2159 2171 50.0 2021 2028 2042 52.5 1886 1896 1910 55.0 1750 1760 1774 57.5 1611 1623 1636 60.0 1470 1484 1494 62.5 1325 1341 1350 65.0 1179 1196 1203 67.5 1033 1049 1055 70.0 886 902 906 72.5 744 756 760 75.0 605 613 615 77.5 473 476 476 80.0 349 350 346 82.5 237 236 230 85.0 139 138 133 87.5 61 61 57 90.0 0 0 0 67.5 3858 3846 3824 3781 3723 3652 3569 3478 3385 3294 3200 3099 2990 2877 2759 2638 2515 2388 2254 2119 1980 1840 1698 1556 1414 1273 1131 991 851 714 579 451 330 221 129 57 0 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 07/11/08 REVISED: 03/11/10 90.0 3858 3846 3824 3780 3720 3646 3557 3464 3373 3283 3188 3087 2978 2864 2744 2621 2491 2355 2215 2075 1931 1789 1645 1506 1367 1228 1090 955 821 690 562 440 326 222 132 60 0 ZONAL LUMEN SUMMARY 0- 5 92. 5- 10 271. 10- 15 434. 15- 20 577. 20- 25 696. 25- 30 790. 30- 35 854. 35- 40 886. 40- 45 890. 45- 50 865. 50- 55 814. 55- 60 737. 60- 65 637. 65- 70 518. 70- 75 385. 75- 80 249. 80- 85 125. 85- 90 32. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. PHONE: (303)442-1255 THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: itl@itlboulder.com • REPORT NUMBER: ITL60564 WEBSITE: www.itlboulder.com DATE: 07/11/08 PREPARED FOR: KENALL LIGHTING REVISED: 03/11/10 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 99 91 83 76 69 64 59 55 51 48 45 97 89 81 74 67 62 57 53 50 47 44 93 82 72 63 56 51 46 42 38 35 33 89 78 69 61 54 49 44 40 37 34 32 85 75 66 59 53 47 43 39 36 33 31 83 70 59 50 43 37 33 29 26 23 21 99 87 76 67 60 53 48 44 40 37 34 99 84 71 60 52 46 41 36 33 30 27 99 80 66 55 47 40 35 31 28 25 23 97 85 75 66 58 52 47 43 39 36 33 97 82 69 59 52 45 40 36 33 30 27 97 79 65 54 46 40 35 31 28 25 23 93 79 67 58 50 44 40 35 32 29 27 93 77 64 53 46 40 35 31 28 25 23 89 76 65 56 49 44 39 35 32 29 26 89 74 62 53 45 39 35 31 28 25 23 85 74 63 55 48 43 38 34 31 28 26 85 72 61 52 45 39 34 30 27 25 23 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.